Home

ControlLogix EtherNet/IP Module Installation Instructions

image

Contents

1. 2 NET status indicator 4 Power supply indicator is green Rockwell Automation Publication 1756 IN603C EN P April 2010 20 Contro Logix EtherNet IP Module Status Indicators Indicator NET Status Off Descripti The mod The mod address ion e is not powered Verify that there is chassis power and that the module is completely inserted into the chassis and backplane e does not have a valid IP address Make sure the module has been configured with a valid IP Flashing green The mod connectio e has an IP address but has no established ns Green The modu e has an IP address and at least one established connection Red The modu e is attempting to use an IP address already in use on the network Assign a unique IP address to the module Link Off The module is not ready to communicate Verify that the modu e has power Green The mod e is ready to communicate Flashing green The mod e is communicating over the network Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 21 Status Indicators Indicator Status Description OK Off Verify that the module has 24V DC chassis power and hat the module is completely inserted into chassis and backplane Flashing green The module is not configured Green The module is operating correctly Flashing red The
2. B C Tick Australian Radiocommunications Act compliant with e AS NZS CISPR 11 Industrial Emissions EtherNet IP e QDVA conformance tested to EtherNet IP specifications See the Product Certification link at http www ab com for Declarations of Conformity Certificates and other certification details Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 25 Additional Resources These documents contain additional information concerning related Rockwell Automation products Resource Industrial Automation Wiring and Grounding Description Provides general guidelines for installing a Guidelines publication 1770 4 1 Rockwell Automation industrial system EtherNet IP Modules in Logix5000 Control Contains information about how to use Systems User Manual publication EtherNet IP modules with various ENET UM001 Logix5000 controllers EtherNet IP Performance and Application Provides detailed EtherNet IP connection Guide publication ENET AP001 information EtherNet IP Media Planning and Installation Provides detailed EtherNet IP connection Guide publication ENET IN001 information ControlLogix Chassis Installation Instructions publication 1756 IN080 Contains information about how to install a ControlLogix chassis ControlLogix Power Supplies Installation Instructions publication 1756 IN078 Contains information about how to install ControlLogix power su
3. 0V m with 200 Hz 50 Pulse 100 AM at 900 MHz 10V m with 200 Hz 50 Pulse 100 AM at 1890 MHz 3V m with 1 kHz sine wave 80 AM from 2000 2700 MHz Immunity EFT B e IEC 61000 4 4 2 kV at 5 kHz on Ethernet port Immunity surge transient e IEC 61000 4 5 2 KV line earth CM on Ethernet port Rockwell Automation Publication 1756 IN603C EN P April 2010 24 ControlLogix EtherNet IP Module Environmental Specifications 1756 EN2T Attribute 1756 EN2T Immunity conducted RF 10V rms with 1 kHz sine wave 80 AM from 150 e IEC 61000 4 6 kHz 80 MHz Certifications 1756 EN2T Certifications 1756 EN2T when product is marked c UL us e ULListed Industrial Control Equipment certified for US and Canada See UL File E65584 e UL Listed for Class Division 2 Group A B C D Hazardous Locations certified for U S and Canada See UL File E194810 CSA e CSA Certified Process Control Equipment See CSA File LR54689C e CSA Certified Process Control Equipment for Class Division 2 Group A B C D Hazardous Locations See CSA File LR69960C FM e FM Approved Equipment for use in Class Division 2 Group A B C D Hazardous Locations CE European Union 2004 108 EC EMC Directive compliant with e EN 61326 1 Meas Control Lab Industrial Requirements e EN 61000 6 2 Industrial Immunity e EN 61000 6 4 Industrial Emissions e EN 61131 2 Programmable Controllers Clause 8 Zone A amp
4. 19350 Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 15 Configure the Module Follow these steps to configure the module 1 In RSLogix 5000 software from the Controller Organizer select New Module 2 Select the module you want to configure For more configuration information refer to the EtherNet IP Modules in Logix5000 Control Systems User Manual publication ENET UMO001 View or download this publication at http www rockwellautomation com literature Apply Chassis Power mn CT 31593 M Rockwell Automation Publication 1756 IN603C EN P April 2010 16 ControlLogix EtherNet IP Module Check Power Supply and Module Status Check the status indicators and alphanumeric display to determine whether the power supply and module are operating properly Description EL OK indicator is red during self test 3 then green NET status indicator 2 LINK status indicator 4 Power supply indicator is green Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 17 The alphanumeric display should cycle through these states e TEST e PASS e OK e REVxx where x x is the module s firmware revision The display then alternates between OK and the module s EtherNet IP address Install or Remove the Module Under Power You can insta
5. C T4A Recommended USB cable Samtec cable PN RSP 119350 for USB port USB port USB 1 1 USB device USB series B receptacle M Use this Conductor Category information for planning conductor routing Refer to Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 23 Environmental Specifications 1756 EN2T Attribute 1756 EN2T Temperature operating 0 60 C 32 140 F e IEC 60068 2 1 Test Ad Operating Cold e EC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock Temperature nonoperating e EC 60068 2 1 Test Ab Unpackaged Nonoperating Cold e IEC 60068 2 2 Test Bb Unpackaged Nonoperating Dry Heat e IEC 60068 2 14 Test Na Unpackaged Nonoperating Thermal Shock 40 85 C 40 185 F Relative humidity 5 95 noncondensing e IEC 60068 2 30 Test Db Unpackaged Damp Heat Vibration 2g 10 500 Hz e IEC 60068 2 6 Test Fc Operating Shock operating 30g EC 60068 2 27 Test Ea Unpackaged Shoc Shock nonoperating 50g EC 60068 2 27 Test Ea Unpackaged Shoc Emissions Group 1 Class A e CISPR 11 mmunity ESD 6 kV contact discharges e IEC 61000 4 2 8 kV air discharges mmunity radiated RF e IEC 61000 4 3 10V m with 1 kHz sine wave 80 AM from 80 2000 MHz 1
6. C EN P April 2010 8 ControlLogix EtherNet IP Module Determine Module Slot Location Install the module in any slot in the ControlLogix chassis You can install multiple 1756 EN2T modules in the same chassis The following figure shows chassis slot numbering in a four slot chassis Slot 0 is the first slot and is always the leftmost slot in the rack 20806 Item Description Item Description 1 Slot 0 4 Slot 3 2 Slot 1 5 Chassis 3 Slot 2 6 Power supply Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 9 Set the Network Address The module ships with the rotary switches set to 999 and BOOTP enabled You can set the network Internet Protocol IP address three ways e Use the rotary switches on the top of the module e Use a BOOTP server or Dynamic Host Configuration Protocol DHCP server such as Rockwell Automation BOOTP DHCP e Use the Rockwell Automation RSLinx or RSLogix 5000 software 3 ko Fo o l wr 2 Item Description 1 Top of module 2 Rotary switches 3 Front of module The module reads the rotary switches first to determine if they are set to a valid number for the last portion of the IP address Valid numbers range from 001 254 When the switches are set to a valid number the module s IP
7. Installation Instructions Allen Bradley ControlLogix EtherNet IP Module Catalog Number 1756 EN2T Topic Page About This Publication 1 Before You Begin Determine Module Slot Location Set the Network Address o co N Install the Module 11 Connect the Module to the EtherNet IP Network Program the Module via the USB Port Configure the Module Apply Chassis Power Check Power Supply and Module Status Install or Remove the Module Under Power ojl aj oy A N Interpret the Status Indicators Specifications 22 About This Publication Use this publication as a guide to install the module This publication describes hardware installation only For configuration information refer to the EtherNet IP Modules in Logix5000 Control Systems User Manual publication ENET UMO001 View or download this publication at http www rockwellautomation com literature Rockwell Allen Bradley Rockwell Software Automation 2 ControlLogix EtherNet IP Module Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment Safety Guidelines for the Application Installation and Maintenance of Solid State Controls Publication SGI 1 1 available from your local Rockwell Automation sales office or online at http Awww rockwellautomation com literature describes some important differences between solid state eq
8. address is 192 168 1 xxx where xxx represents the number set on the switches The module s subnet mask is 255 255 255 0 and the gateway address is set to 0 0 0 0 The module does not have a host name assigned or use any Domain Name System when using the rotary switch settings Rockwell Automation Publication 1756 IN603C EN P April 2010 10 ControlLogix EtherNet IP Module To reset the module to its initial out of the box settings reset the switches to 888 and cycle power IMPORTANT Do not use the 888 switch setting during normal module operation After cycling power with the switches set to 888 remove the module and set the switches to their final value When you set the rotary switches to a value other than 888 or to the valid IP address values 001 254 the software configuration determines the IP address Determining the Module IP Address lf BOOTP DHCP is The module Enabled Asks for an address from a BOOTP DHCP server The server also assigns other Transport Control Protocol TCP parameters Not enabled Uses the IP address along with other TCP configurable parameters stored in nonvolatile memory Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 11 Install the Module Follow this procedure to install the module 1 Align the circuit board with top and bottom guides in the chassis oo 0 se Ws INA Item Description Ci
9. isit http www rockwellautomation com support Installation Assistance If you experience a problem within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your product up and running United States or Canada 1 440 646 3434 i F Use the Worldwide Locator at Outside United States or i Canada http www rockwellautomation com support americas phone_en html or contact your local Rockwell Automation representative New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures Contact your distributor You must provide a Customer Support case number United States call the phone number above to obtain one to your distributor to complete the return process Please contact your local Rockwell Automation representative for the return Outside United States procedure Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA DU002 available at http www rockwellautomation com literature Allen Bradley ControlLogix Rockwell Software Rockwell Automatio
10. its marqu s CL DIV 2 GP A B C D ne conviennent qu une utilisation en environnements de Classe Division 2 Groupes A B C D dangereux et non dangereux Chaque produit est livr avec des marquages sur sa plaque d identification qui indiquent le code de temp rature pour les environnements dangereux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes inspection par les autorit s locales qualifi es au moment de l installation WARNING A Explosion Hazard e Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous e Do not disconnect connections to his equipment unless power has been removed or the area is nown to be nonhazardous Secure any external connections hat mate to this equipment by using screws sliding latches hreaded connectors or other means provided with this product Substitution of components may impair suitability for Class Division 2 e If this product contains batteries hey must only be changed in an area known to be nonhazardous AVERTISSEMENT Risque d Explosion Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher l quipement e Couper le co
11. ll or remove this module while chassis power is applied WARNING When you insert or remove the module while A backplane power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Repeated electrical arcing causes excessive wear to contacts on both the module and its mating connector Worn contacts may create electrical resistance that can affect module operation 1 Push on upper and lower module tabs to disengage them m mD Rockwell Automation Publication 1756 IN603C EN P April 2010 18 ControlLogix EtherNet IP Module 2 Slide the module out of the chassis IMPORTANT If you want to replace an existing module with an identical one and you want to resume identical system operation you must install the new module in the same slot Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 19 Interpret the Status Indicators If the alphanumeric display and status indicators do not sequence through the expected states refer to these tables The three bi color red green status indicators on the module provide diagnostic information about the module and its connections to the network EtherNet IP OK indicator is red during self test then green LINK status indicator
12. module detected a recoverable fault A configuration error may have caused the fault Check he module configuration If necessary reconfigure he module Red The module detected an unrecoverable fault Cycle power to the module If this does not clear the fault eplace the module Red and Update the firmware image Once the image is alphanumeric display updated cycle power If this does not clear the fault scrolls Image eplace the module Update Needed Flashing red and The module is performing a power up self test green Rockwell Automation Publication 1756 IN603C EN P April 2010 22 ControlLogix EtherNet IP Module Specifications Technical Specifications 1756 EN2T Attribute 1756 EN2T Enclosure type rating None open style Module location Any slot in the ControlLogix chassis Backplane current 1 A at 5 1V DC Backplane current 3 mA at 24V DC Isolation voltage 30V continuous Basic Insulation Type Ethernet to backplane No isolation between USB and backplane Type tested at 510V AC for 60 s Power dissipation max 5 1 W Wire size Ethernet connections RJ45 connector according to IEC 60603 7 2 or 4 pair Category 5e minimum cable according to TIA 568 B 1 or Category 5 cable according to ISO IEC 24702 Wiring category 2 on Ethernet ports Temperature surrounding 60 C 140 F air North American temp code Series A T5 Series B and
13. n and TechConnect are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Rockwell Otomasyon Ticaret A Kar Plaza ly Merkezi E Blok Kat 6 34752 erenk y stanbul Tel 90 216 5698400 www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication 1756 IN603C EN P April 2010 PN 74517 Supersedes Publication 1756 IN603B EN P January 2009 Copyright 2010 Rockwell Automation Inc All rights reserved Printed in the U S A
14. n Guide publication ENET AP001 e EtherNet IP Media Planning and Installation Guide publication ENET IN001 Rockwell Automation Publication 1756 IN603C EN P April 2010 14 ControlLogix EtherNet IP Module Program the Module via the USB Port WARNING The USB port is intended for temporary local A programming purposes only and is not intended for permanent connection If you connect or disconnect the USB cable with power applied to this modu e or any device on the USB network an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding A Samtec Inc RSP 11 9350 USB cable is required to maintain hazardous location certifications Be sure that power is removed or the area is nonhazardous before proceeding The module has a USB device port that uses a series B receptacle To use the USB port you must have RSLinx software version 2 51 or later installed on your computer Use a USB cable to connect your computer to the USB port The connection lets you download programs to controllers and to configure Ethernet modules directly from your computer ATTENTION A e The USB port is designed for a temporary connection only e The USB cable is contain hubs not to exceed 3 0 m 9 84 ft and must not e To maintain product certification integrity you must use SAMTEC cable part number RSP 1
15. pplies ControlLogix Power Supplies Installation Instructions publication 1756 IN596 Open DeviceNet Vendor Association ODVA website http www odva org Contains information about how to install ControlLogix power supplies Provides information about implementing EtherNet IP technology You can view or download publications at http www tockwellautomation com technical documentation contact your or sales representative literature To order paper copies of ocal Rockwell Automation distributor Rockwell Automation Publication 1756 IN603C EN P April 2010 26 ControlLogix EtherNet IP Module Notes Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 27 Notes Rockwell Automation Publication 1756 IN603C EN P April 2010 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products At http www rockwellautomation com support you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make the best use of these tools For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or v
16. rcuit board 2 Slide the module into the chassis Rockwell Automation Publication 1756 IN603C EN P April 2010 12 ControlLogix EtherNet IP Module Make sure that the module backplane connector properly connects to the chassis backplane TIP The module is properly installed when it is flush with the power supply or other installed modules Connect the Module to the EtherNet IP Network WARNING If you connect or disconnect the communication cable A with power applied to this module or any device on the network an electrical arc can occur This could cause an explosion in hazardous location installations 1 Be sure that power is removed or the area is nonhazardous before proceeding 2 Attach the RJ45 connector to the Ethernet port on the bottom of the module as shown Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 13 Description RJ45 connector underneath module IMPORTANT We recommend connecting the module to the network via a 100 MB Ethernet switch which will reduce collisions and lost packets and increase network bandwidth For detailed EtherNet IP connection information see the following publications e EtherNet IP Performance and Applicatio
17. rty damage or economic loss Attentions help you identify a hazard avoid a hazard and recognize the consequences SHOCK HAZARD Labels may be on or inside the equipment for example drive or motor to alert people that dangerous voltage may be present BURN HAZARD Labels may be on or inside the equipment for example drive or motor to alert people that surfaces may reach dangerous temperatures Pi PEE IMPORTANT dentifies information that is critical for successful application and understanding of the product Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 3 North American Hazardous Location Approval The following information applies when operating this equipment in hazardous locations Products marked CL I DIV 2 GPA B C D are suitable for use in Class Division 2 Groups A B C D Hazardous Locations and nonhazardous locations only Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code When combining products within a system the most adverse temperature code lowest T number may be used to help determine the overall temperature code of the system Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation Informations sur l utilisation de cet quipement en environnements dangereux Les produ
18. to prevent or minimize the spread of flame complying with a flame spread rating of 5VA V2 V1 VO or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications In addition to this publication see e Industrial Automation Wiring and Grounding Guidelines Rockwell Automation publication 1770 4 1 for additional installation requirements e NEMA Standard 250 and IEC 60529 as applicable for explanations of the degrees of protection provided by different types of enclosure Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 5 Prevent Electrostatic Discharge ATTENTION This equipment is sensitive to electrostatic A discharge which can cause internal damage and affect normal operation Follow these guidelines when you handle this equipment e Touch a grounded object to discharge potential static e Wear an approved grounding wriststrap e Do not touch connectors or pins on component boards e Do not touch circuit components inside the equipment e Use a static safe workstation if available e Store the equipment in appropriate static safe packaging when not in use Rockwell Automation Publication 1756 IN603C EN P April 2010 6 ControlLogi
19. uipment and hard wired electromechanical devices Because of this difference and also because of the wide variety of uses for solid state equipment all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable In no event will Rockwell Automation Inc be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited Throughout this manual when necessary we use notes to make you aware of safety considerations WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment which may lead to personal injury or death property damage or economic loss ATTENTION Identifies information about practices or circumstances that can lead to personal injury or death prope
20. urant ou s assurer que l environnement est class non dangereux avant de d brancher les connecteurs Fixer tous les connecteurs externes reli s a cet quipement a l aide de vis loquets coulissants connecteurs filet s ou autres moyens fournis avec ce produit e La substitution de composants peut rendre cet quipement inadapt une utilisation en environnement de Classe I Division 2 e S assurer que l environnement est class non dangereux avant de changer les piles A Rockwell Automation Publication 1756 IN603C EN P April 2010 4 ControlLogix EtherNet IP Module Environment and Enclosure A ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications as defined in IEC 60664 1 at altitudes up to 2000 m 6562 ft without derating This equipment is considered Group 1 Class A industrial equipment according to IEC CISPR 11 Without appropriate precautions there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbances This equipment is supplied as open type equipment It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The enclosure must have suitable flame retardant properties
21. x EtherNet IP Module About the Module Use this figure to identify the external features of the module un yo EEE 1 AL 10 F 2 e g Yo y De L LL 8 E a A l 4 i I ij I J Pi I 2 6 dA Item Description Item Description 1 Top view 6 Front of module 2 Backplane connector 7 RJ45 cable connector on underside of module 3 Side view 8 USB port 4 MAC ID label g Front panel on opposite side of circuit board 5 Bottom view 10 Front view Rockwell Automation Publication 1756 IN603C EN P April 2010 ControlLogix EtherNet IP Module 7 Before You Begin Before you install the module you must install and connect a ControlLogix chassis and power supply To install these products refer to these publications Chassis Type Chassis Power Supply Power Supply Installation Installation Series B 1756 A4 1756 A7 Publication 1756 PA72 C Publication 1756 A10 1756 A13 1756 IN080 1756 PB72 B 1756 IN078 1756 PA75 B Publication 1756 IN596 1756 PB75 B Rockwell Automation Publication 1756 IN603

Download Pdf Manuals

image

Related Search