Home
Stanhope-Seta Catalog
Contents
1. Measuring Channels 8 15 Counts per Measurement max 16 000 000 16 000 000 m m m Sample Viscosity max 68mm s from sample bottle 500mm 2 s 10bar 68mm s from sample bottle 500mm s 10bar Sample Temperature Range Jo to 80 C Jo to 80 Size Bands Reported During Test As specified in Test Method As specified in Test Method Size Bands Reported on Recall As specified in Test Method Results Particles ml cumulative and distributive ISO Codes to ISO 4406 1999 cumulative All channels Particles ml or Particles 10ml Test Method dependant Cumulative and Distributive Cleanliness Codes Cumulative or Distributive Test Method dependant Cell Volume Flow Rate 10ml Q 30ml min includes rinse cycles for IP 565 10 bar 310 bar with SA1 008 0 option Total Sample Volume used typ Sample Pressure max Display and Control LCD display 4 key operation 10ml 30ml min 10 bar 310 bar with SA1008 0 option 80ml includes rinse cycles for IP 565 amp ASTM Multifuel 20ml other methods Touch sensitiv
2. Seta Part Hole Diameter Size W x L 11808 0 25mm 152 x 152mm 11809 0 32mm 152 x 152mm 11811 0 38mm 152 x 152mm 11812 0 50mm 152 x 152mm 11813 0 70mm 152 x 152mm DISTILLATION FLASK ACCESSORIES Seta Part Description 0 11804 0 FLEXIBLE STOPPER CAP for side arm pack of 10 11806 0 THERMOMETER CENTRING DEVICE for straight neck flask 11807 0 THERMOMETER CENTRING DEVICE for NS type flask 11814 0 CORK for 11890 0 amp 11940 0 pack of 100 11815 0 CORK for side arm pack of 100 11869 002 BOILING STONES pack of 3 o DISTILLATION FLASKS Seta Part Volume Description 11950 0 100ml Pack of 5 11940 0 125ml NS type pack of 5 11890 0 125ml Straight neck pack of 5 11960 0 200ml E133 pack of 5 11962 0 200ml D850 pack of 5 11970 0 250ml Pack of 5 RECEIVERS Seta Part Volume Form Notes 22159 0 25ml Parallel Pack of 3 22160 0 100ml Parallel Pack of 3 122161 0 200ml Parallel Pack of 3 11910 004 100ml Crow Type Pack of 2 29 Distillation Heference Methods BV PAM DISTILLATION UNIT PRECISION AUTOMATED MANUAL DISTILLATION UNIT ASTM D86 D850 D1078 E123 IP 123 IP 191 IP 195 EN 3405 BS 2000 Parts 123 191 amp 195 BS 7392 ISO 918 ISO 3405 DIN 51 751 NF M07 002 JIS K2254 AUTOMATIC DATA COLLECTION SETA ORBIS DIGISTILLU95 THERMOMETER AND DATA PROCESSOR 97005 0 ASTM 086 0850 01078 E123 IP 123 IP 191 IP 195 EN 3405 BS 2000 Parts 123 191 am
3. a 10600 0 and 10610 0 with Accessories Size HxWxD Weight 2 1kg SETA FOUR WAY CONRADSON TEST UNIT REQUIRED 10710 0 PORCELAIN CRUCIBLE pack of 10 10720 0 SETA BURNER for Coal Gas 10730 0 GLASS BEADS 1kg pack 10740 0 SETA BURNER for LP Gas 10750 0 SETA BURNER for Natural Gas Methane THERMOMETERS ASTM8F 8C _ Note ASTM D2416 requires an electric furnace in place of the burners Other items which may be required include Charging syringe Dessicator Strainer 100 mesh Comprises a four unit stand and four each of the following Skidmore iron crucible with cover spun sheet iron crucible with cover spun steel circular hood with chimney spun steel circular insulation block and Nichrome wire support Size HxWxD 26 x 79 x 29cm Weight 15kg 99100 2 ANALYTICAL BALANCE for details see page 141 RAMSBOTTOM CARBON RESIDUE BATH ACCESSORIES Ramsbottom Carbon Residue Bath Il NCE i ASTM 0524 IP 14 BS 2000 Part 14 BS 4451 obs ISO 4262 10890 0 COKE BULB borosilicate glass pack of 50 FTM 791 5002 NF T60 117 10920 0 TONGS for removing coke bulb from the block bath 5test wells 10910 0 COKE BULB FILLING RACK a five unit rack arranged to accommodate syringes of 5 or 10ml type Facilitates filling of Coke Bulbs Temperature range ambient to 550 C 99100 2 ANALYTICAL BALANCE for details see page 141
4. 110 120V 50 60Hz 220 240V 50 60Hz 6 110 120V 50 60Hz 220 240V 50 60Hz 110 120V 50 60Hz 220 240V 50 60Hz 200W 200W Weight 3 5kg 3 5kg 10kg 12kg Seta Part No Name 24500 0 SETA STEEL STAND 23 x 14cm base with a 12 7mm diameter steel rod 76cm high suitable for use with 24410 4 and 24415 2 Distillation Flask Heaters 24520 0 CLAMP for holding glassware three fingered padded jaw to protect and grip glassware fully open capacity 90mm 24650 2 BOSSHEAD for attaching 24520 0 Clamp to 24500 0 Stand 24440 0 CONDENSER Reflux type 40cm effective length B19 Cone 24445 0 DRYING TOWER amp STOPPER 24401 0 DISTILLATION FLASK 500ml B24 Cone 24402 0 DISTILLATION FLASK 1000ml B24 Cone TES 11900 0 Seta Part No Name Trap Size Gradi auon Range Condenser Joint Methods Division End Joint 24450 0 RECEIVER 2 0ml 0 05ml 0 1 to 2 0ml Round B19 Cone B24 Cone 24460 0 RECEIVER 3 0ml 0 05ml 0 to 3 0ml Round B19 Cone B24 Cone 24465 0 RECEIVER 5 0ml 0 05ml 0 to 5 0ml Round B19 Cone B24 Cone 24470 0 RECEIVER 7 5ml 0 1ml 0 5 to 7 5ml Round B19 Cone B24 Cone 24480 0 RECEIVER 10 0ml 0 1ml 1 to 10ml Round c w Stopcock B19 Cone B24 Cone 24490 0 RECEIVER 12 5ml 0 1ml 0 to 12 5ml Round B19 Cone B24 Cone 24495 0 RECEIVER 25 0ml 0 2ml 5 to 25ml Conical B19 Cone B24 Cone BS756 24497 0 RECEIVER 25 0ml Conical B19 Cone B24 Cone IP 74 24510 0 RECEIVER 2
5. Voltage 110 120V 50 60Hz 220 240V 50 60Hz Poen MN Size HxWxD __ 60 38 3 Weight s ACCESSORIES REQUIRED 11241 0 SILICONE CARBIDE PAPER 105 150 grit FEPA 28 x 23cm pack of 50 11460 0 SILICONE CARBIDE PAPER 65ym 240 grit FEPA 28 x 23cm pack of 50 11470 0 SILICONE CARBIDE PAPER 100 grit FEPA 28 x 23cm pack of 50 11480 0 SILICONE CARBIDE GRAINS 105 150 mesh 5 packs of 500g 11530 0 SETA MULTI STRIP VICE to hold copper strips while being polished 11570 0 FLAT GLASS TEST TUBE to protect strip during inspection pack of 10 11580 0 COPPER STRIP CORROSION STANDARD a set of thirteen plaques printed on aluminium and encased in plastic for protection 22150 5 SETA LPG CORROSION PRESSURE VESSEL for details see separate entry 22190 0 COPPER TEST STRIP 75 x 12 5 x 2 4mm with 3 0mm hole pack of 30 22230 0 SETA BRACKET holds Pressure Vessel correctly in bath pack of 3 THERMOMETERS ASTM12C IP64C or ASTM12F IP64F 22220 4 with 22150 4 supplied separately SETA LPG CORROSION PRESSURE VESSEL ASTM D1838 IP 411 150 6251 NF M41 007 BS 2000 Part 411 BS 6924 EN 6251 Pressure tested to 6890kPa 1000psi Used to determine the resistance to corrosion of a polished copper strip when immersed in LPG Comprises polished stainless steel vessel with two stainless steel needle valves dip tube and O ring sealed cap Tested to 6890kPa 1000psi 22150 5
6. VERIFICATION OIL CALIBRATION CERTIFICATE UKAS Viscosity Range Jet Orifice Dia Seta Viscosity Flow Time Seta mm s Code inches Part No mm s seconds Part No 20 to 80 2 0 0995 23340 2 65 5 61 to 66 99891 0 40 to 220 3 0 134 23350 2 65 5 33 to 36 99891 0 74 to 360 4 0 182 23360 2 1 150 32 to 35 99892 0 eJ min UP FLOW CUP VERIFICATION OIL CALIBRATION CERTIFICATE UKAS Viscosity Range Orifice Dia Seta Viscosity Flow Time Seta cP Code Part No cP seconds Part No 5 to 140 1 2 5 23215 0 N A N A N A 50 to 1 100 2 4 0 23216 0 N A N A N A 510 to 5 100 3 6 0 23217 0 N A NA FLOW CUP VERIFICATION OIL OPTIONAL CALIBRATION CERTIFICATE WORKS Q CALIBRATION CERTIFICATE UKAS Viscosity Range Cup Seta Part No Viscosity Flow Time Seta cP Code std cert mm s seconds Part No 120 to 85 1 23150 0 23150 0Y 26 2 52 to 54 99890 0 30 to 170 2 23760 0 23160 0Y 115 45 to 48 99892 0 170 to 550 3 23770 0 23770 0 453 44 to 48 99894 0 200 to 900 4 23780 0 23780 0Y 453 34 to 37 99894 0 1250 to 1 200 5 23190 0 23190 0Y 1 680 70 to 78 99895 0 ACCESSORIES Flow Cups 23520 0 SETA PROTECTIVE COLLAR FOR TYPE B AND FORD CUPS 23660 0 SETA STAND to support all flow cups with adjustable feet for levelling spirit level and square glass scraper 23680 0 SETA SPIRIT LEVEL circular type to suit all cups 23661 0 SIGHT SCREEN FLOW CUP a
7. 50 51 ASTM 5949 150 151 150 151 ASTM 05985 150 151 A IMDOD MM ASTM 06079 150 151 ASTM 06082 103 149 ASTM 06217 82 ol T 32 150 ASTM 06378 22 23 91 152 ASTM 06426 COLD SOAK aaa 83 33 ASTM 06591 91152153 ASTM 06749 190 151 ASTM 06751 110 MM ASTM D6892 190 151 ASTM D7236 sess 2 8 10 13 15 156 ASTM D7279 Houillon Method 32 34 CDL MN 69 72 73 ASTM D7467 10 ASIM DIIM NM 31 ASTM Draft Standard test method for 80 81 counting amp sizing particles in light and middle distillate fuels and liquid Bio Fuels by automatic particle counter ASTM EB n 54 ASTM E102 46 Method page ASTM E128 C ua 30 31 ASTM E188 mnt 28 29 ASTM E808 5 o 112 ASTM E502 a 2 4 7 8 10 13 17 18 ASTMMicro u 60 ASTM Tapered Hole Disc 60 AASHTO TA o 2 6 19 72 os 6 7 811 18 AASHTOT78 obs ss AOSCStandard Cc 16 00 60 2542 108 API2946 5 121 API2947 132134 API2948 108 API2560 31 API2561 88 API 5 Chapter 8 5 5 s 121 APIMPMS Chapter 102 ee 31 APIMPMS Chapter 103 5 5 sss 108 APIMPMS Chapter 10 5 3 sso 5 1767 115 BS188 O 45 32 34 36 38 BS658 27 28 29 BS2000Part 5 50 50 51 BS2000Part 9 50 103 BS2000Part27 31 BS 2000 Part 33 obs 18 BS 2000 Part 24 BS2000Part35 550 18 BS
8. O LLLLLXU 12600 0 PORTABLE DENSITY MEASUREMENT KIT 0 to 1 999g cm range single hand operation Density and SG measurements Explosion proof Ex Il 2 G EEx ib IIC T5 Petrol and organic solvent resistant Automatic temperature compensation Density standards included in the kit IP PM DN Determination of density of middle distillate fuels Hand held oscillating U tube density meter method A portable solution for rapidly determining the density specific gravity or concentration of samples the Portable Density Measurement Kit comprises a handheld density meter sampling probe and three density standards all packed into a rugged carrying case The density meter is intrinsically safe and ATEX certified as explosion proof making it suitable for use in the field The oscillating U Tube type density meter draws sample into the measurement chamber via a spring loaded plunger action pump Alternatively sample can be introduced by syringe through the supplied Luer adaptor The internal seals are manufactured from Kalrez and are resistant to attack from petrol and similar organic solvents Density measurements and temperature are shown on a large digit LCD display and can be stored recalled from the on board memory The sample temperature is taken at the measuring cell and compensation can be applied automatically Included with the kit are 100ml bottles of 0 9720 20 C 0 8540 20C and 0 8200 20 UKAS certified den
9. 83750 3 SETATIME SIX CHANNEL QUARTZ TIMER for time measurement to 999 99 x2 CALIBRATION CERTIFICATE UKAS OPTIONAL seconds accuracy 99 999 1 digit at 20 for details see page 141 Seta Part No Seta Part No DEUS 84003 0 COVERS for unused holders in Hee heat loss pack vd Works Cert UKAS Cert Set Point C Range C 84004 0 CAPS for sealing space around viscometer limbs Can be modified to suit 83640 0 83640 0Z 40 38 6 to 41 4 all viscometer tubes 6 required 83641 0 83641 0Z 100 48 6 to 51 4 84005 0 SPIRIT LEVEL 84008 0 BENCH VISCOMETER STAND framework holds viscometer tubes near 23150 2 UNIVERSAL VISCOMETER HOLDER for all regular viscometer tubes 6 vertical while being prepared or while draining after use complete with required i j drainage tray 7 84102 0 DENSITY MEASURING KIT adapter to allow use of glass hydrometers For m PORA A M Re cn X tests at 15 the 99300 2 bath is required for details see below Gad 5 RESUS 5 99300 2 MINI LOW TEMPERATURE BATH CIRCULATOR to provide chilled water if ambient to 80 C 3 required OR local supply exceeds 18 C for details see page 139 94635 0 BATH OIL 20 litres for filling vi 97100 0 VISCOMETER TUBE CLEANER for details see 39 20 litres for filling viscometer baths in the temperature range o 80 to 120 C 3 required 45001 0 SETAPLUS EXTENDED 12 MONTH WARRANTY OR 94632 0
10. E Accuracy 33 to 100 C 0 5 C A portable instrument designed to provide quick and accurate calibration of thermocouple and 100 to 300 C 1 C RTD temperature probes Well Diameters 1 4 3 16 2off 5 32 1 8 and 1 16 inch A precision temperature controlled oven heats an aluminium block drilled with various diameter holes Power Supply 115 VAC 210 50 60Hz to accept the probe being calibrated The current temperature of the block and the set temperature 230 VAC 10 50 60Hz are displayed on an LCD The temperature can be set to between 33 and 300 C in 0 1 C increments Size HxWxD 57x 125x 15cm SUPPLIED WITH mains lead and instruction manual Weight Vi CALIBRATION CERTIFICATE UKAS 144 44 0 1932 564391 F 44 0 1932 568363 LE sales stanhope seta co uk W www stanhope seta co uk Pressure Calibration amp Verification 99915 0 HANDHELD DIGITAL PRESSURE INDICATOR Verification and recalibration of pressure gauges transducers and pressure transmitters A portable battery operated precision DECIEI pressure indicator in waterproof case to IP 54 UN Ranges 0 to 2000mbar Pressure is displayed on a high resolution qawa dl LCD and different units of measurement can Accuracy 0 1 Full Scale be selected The instrument has memory and Units of amata ma peak hold facilities An RS232 output allows Measurement _ Ambient temperature in C or F information to be
11. HHB E FIL e we as Pa oum ues Zia DINE En dep LI Elk Rm RE E d 8 s imi i AE ees Kissa 3 da m t ipsa Tul nn _ mmc a Uno et Chem w e tm iw a ee p si dme LE ams Em a Eks 88 m dm imm bunam Kinematic Capillary Viscosity SETAVIS AUTOMATIC KINEMATIC VISCOMETER ACCESSORIES Setavis Double 6 Kinematic Auto Vis SETAVIS KAV AUTO DUPLEX TUBES Complete with auto detection sensor head and leads The range covers 2 5 to 2000mm s Calibration is based on a minimum flow time of 50 seconds at 40 C CALIBRATION CERTIFICATE WORKS Seta Part No Nominal Constant Sample Volume ml 83605 003 0 05 0 15 2 5 to 30 83605 004 0 1 0 175 5 to 60 83605 005 0 3 0 175 15 to 180 83605 006 0 5 0 225 25 to 300 83605 007 1 0 0 250 50 to 600 83605 008 3 0 0 250 150 to 1200 83605 009 5 0 0 275 250 to 2000 SETA KINEMATIC VISCOSITY BATH THERMOMETERS With ice point scale and 0 02 C subdivisions to allow easy reading to within 0 01 C CALIBRATION CERTIFICATE WORKS CALIBRATION CERTIFICATE UKAS OPTIONAL Seta Part No Seta Part No Temperature Temperature Works Certificate UKAS Certificate Set Point C Range 83620 0 83620 0Z 40 38 6 to 41 4 83622 0 83622 0Z 50 48 6
12. Small Scale Flash Point Flash Point Smoke Point amp Sustained Burning SMALL SCALE FLASH POINT Small scale flash point testers are universally specified in many Fully meeting the requirements of Rapid Equilibrium methods ISO international regulations to define and classify flammable and 3679 3680 Setaflash Testers are the only small scale instruments with combustible substances They provide the most precise and fastest flash detection Setaflash is specified by ASTM D1655 and the UK means of carrying out flash point tests on a definitive flash no flash basis DEFSTAN 91 91 for testing Aviation Turbine Fuels Diesel 0975 Fuel Oil both in the laboratory and the field A 2ml sample size and 1 minute test D396 Gas Turbine Fuel D2880 and Kerosine D3699 and is the only time for low temperature tests make these instruments ideally suited for instrument recommended for testing waterborne paints In Europe it is many applications Petrochemicals Biodiesel FAME adhesives foods specified in the specifications for FAME Heating and Automotive Fuels flavours cosmetics paints varnishes waste pharmaceuticals polishes EN 14214 and EN 14213 and aerosols are just some of the products routinely tested Portable Setaflash Series 3 Range Simple to Use Small Sample Size Easy to Use Menu System Setaflash Series 8 T Tt fi Cup temperature 16 BC Ramp range 51 C to BIC Sample ID
13. P75F with collar for tests to IP 33 only pack of 2 CALIBRATION VERIFICATION amp TRAINING Size HxWxD 13032 3 99850 0 MULTI TEST VERIFICATION MATERIAL IP 170 Kerosine for details see page 150 13811 3 13663 0 71001 0 Cleveland Flash Point SETA SEMI AUTOMATIC CLEVELAND OPEN CUP TESTER ASTM D92 IP 36 EN ISO 2592 BS 2000 Parts 36 amp 403 obs NF T60 118 FTM 791 1103 7 JIS K2265 AASHTO T48 Ambient to 400 C temperature range Variable ramp rate Electrically driven sweep arm The 13811 3 comprises an electrically heated sample cup variable ramp rate controller and a button operated electrically driven sweep arm with test jet The test flame uses either mains gas or can operate from a 13667 0 Portable Gas Tank 36650 SETARAMP CONTROLLER Automated temperature control for Seta 13811 3 and 13661 3 testers Programmable Audible prompt 13663 0 is an automated temperature control unit for Seta 13811 3 and 13661 3 flash point testers The start temperature ramp rate C min and test temperature interval C are entered by the operator via a keypad A digital display shows the parameters set and the temperature of the sample Setaramp overrides the flash on board controller giving more accurate ramp rates SETA VENT e Draught shield with fume extractor The Seta Vent is suitable for use with any of the Seta
14. Simultaneous measurement of 4 test vessels Automatic end point detection Simple two point calibration facility An automatic pressure monitoring system designed to be used with 15802 0 oxidation vessels and to match the 15400 5 bath but can be used with other suitable baths Comprises two digital pressure monitors each capable of monitoring two vessels with a membrane switch control panel The unit can also be used to display oxygen pressure whilst charging vessels The control unit when connected to a computer via the DB25 port and using the Seta OXS Software supplied allows automatic end point detection induction period determination data logging and graphical printed output functions The maximum run time may be selected as either 24 or 96 hours SUPPLIED WITH DB25 cable OXS software mains lead and instruction manual Note An IBM compatible personal computer not supplied is required ACCESSORIES REQUIRED 15455 0 Auto Oxidation Control Unit TRANSDUCER complete with lead Note 1 required for each oxidation vessel CALIBRATION CERTIFICATE WORKS CALIBRATION PLUG plugs into transducer input to indicate calibration accuracy of 15450 3 OPTIONAL 15620 2 SETA OXYGEN CHARGING LEAD for connecting oxygen supply to oxidation vessel when not using 15400 4 bath CALIBRATION VERIFICATION amp TRAINING 80005 2 PRESSURE CALIBRATOR used to recalibrate pressure monitors for details see page 146
15. To order a glass capillary viscometer tube with a UKAS calibration certificate add the suffix Z to the part number i e 11677 02Z Kinematic Capillary Viscosity UON Tin 1l IX V LV OUUIVILE I LI Inm L F GLASS CAPILLARY KINEMATIC VISCOMETER TUBES Viscosity Range mm s Size Code Seta Part No ir 10 5 to 2 0 0 002 25 11634 01 N0 8 N1 0 0 8 to 4 0 0 004 50 11634 02 N1 0 N2 1 6 to 8 0 0 008 75 11634 03 S3 S6 3 0 to 15 0 015 100 11634 04 D5 D10 7 0 to 35 0 035 150 11634 05 N10 20 20 to 100 0 1 200 11634 06 N35 S60 50 to 250 0 25 300 11634 07 N100 200 100 to 500 0 5 350 11634 08 200 N350 240 to 1 200 1 2 400 11634 09 N350 600 500 to 2 500 2 5 450 11634 10 N1 000 2 000 1 600 to 8 000 8 0 500 11634 11 D5 000 N4 000 4 000 to 20 000 20 0 600 11634 12 N15 000 S30 000 CANNON FENSKE OPAQUE Viscosity Range mm s d Size Code Seta Part No rag 0 5 to 2 0 0 002 25 11641 01 N0 8 N1 0 08 to 4 0 0 004 50 11641 02 N1 0 N2 1 6 to 8 0 0 008 75 11641 03 3 S6 13 0 to 15 0 015 100 11641 04 D5 D10 7 0 to 35 0 035 150 11641 05 N10 20 20 to 100 0 1 200 11641 06 N35 S60 50 to 250 0 25 300 11641 07 N100 200 100 to 500 0 5 350 11641 08 200 N350 240 t
16. 15456 0 PORTABLE CAMBRIDGE PRESSURE RECORDER Range 550 to 1380kPa 80 to 200psi Simultaneous measurement of 2 test vessels Twenty four hour recording time Oxygen safety device An oxygen safe 24 hour electrically driven chart recorder for monitoring two oxidation vessels within a range of 550 to 1380kPa 80 to 200psi SUPPLIED WITH 5 red pens 5 green pens and pack of 100 charts kPa ACCESSORIES Portable Cambridge Pressure Recorder REQUIRED 15460 0 OXYGEN CHARGING AND PURGING KIT contains oxygen charging lead and pressure gauge SETA PRESSURE TRANSMITTING CAPILLARY for connecting oxidation vessel to 15611 0 Pressure Recorder Note 1 required for each vessel 15640 0 SETA PRESSURE GAUGE 0to 1380kPa 0 to 200psi Oxygen safe 75mm diameter oxygen safe pressure gauge with a 0 to 1 380kPa 0 to 200psi range Suitable for use with Seta 15800 4 and 15802 0 Oxidation Vessels Note 1 required for each pressure vessel Oxidation Stability Oxidation OXIDATION STABILITY CONSOLE BATH 15450 3 SOFTWARE INCLUDED 2 CALIBRATION amp VERIFICATION MATERIALS 110 120V 50 60Hz 220 240V 50 60Hz switc hable 45 x 38 x 19cm SPECIFICATIONS Pressure range x 550 to 1380kPa 80 to 200psi Twin pen 110 120V 60Hz 220 240V 50Hz 60Hz 66 x 48 x 38cm Size HxWxD Oxidation 15550
17. AF IUATIUNO EQUIRED Temperature Range Ambient 5 to 100 C 1 15802 0 SETA OXIDATION VESSEL with mandatory burst disc as required by ASTM Bath Type Dry Block D525 D873 IP 40 amp IP 138 for details see page 66 Max No of Test Vessels 4 PRESSURE CERTIFICATE UKAS Heat Up Time to 100 C uS 15803 0 SETA VESSEL CLAMP to hold vessels during opening and closing can be L bench mounted Voltage 220 240V 50 60Hz 15805 0 SPANNER for oxidation vessel Power Comsumption 3kW max 15810 0 SETA LINER borosilicate glass with cover pack of 3 Size HxWxD 30 x 60 x 28cm AUTOMATIC PRESSURE MONITORING Weight 65kg SETA AUTO OXIDATION CONTROL UNIT for details see page 67 m ENHANCED ANALOGUE PRESSURE MONITORING PRESSURE MONITORING OPTIONS TEMS REQUIRE 15611 2 PORTABLE CAMBRIDGE PRESSURE RECORDER for details see page 67 Seta Part No 1Vessel 2Vessels 3Vessels 4 Vessels OR AUTOMATIC PRESSURE MONITORING ANALOGUE PRESSURE MONITORING 15450 3 Seta Auto Oxidation Control Unit 1 1 1 1 15600 0 SETA PRESSURE GAUGE for details see page 67 ENHANCED do E PRESSURE MONITORING THERMOMETERS 15611 2 Portable Cambridge Pressure Recorder 1 1 2 2 ASTM22C IP24C or ASTM22F IP24F ANALOGUE PRESSURE MONITORING Note Other items which may be required include Solvents Filtering crucible Oxygen 15600 0 Seta Pressure Gauge 2 3 4 A 6 POSITIO
18. Bath capacity 60 litres Fluid type TI Temperature 100 C Max no of Test vessels l4 Vessel charging 1380kPa 200psi maximum Vessel cooling Cold water plunge tank Voltage 110 120V 50 60Hz 220 240V 50 60Hz Power 3kW Size HxWxD 135x 83x 77cm Weight SETA OXIDATION VESSEL ASTM D525 D873 IP 40 IP 138 BS 2000 Parts 40 and 138 Fitted with burst disc assembly Pressure tested to 2480kPa 360 psi An oxidation pressure vessel with a safety burst disc assembly and discharge tube in accordance with ASTM D525 D873 IP 40 and IP 138 Comprises a stainless steel vessel with a screw top closure and O ring seal stem needle valve quick connection Schrader male coupling for oxygen charging and a fitting for pressure monitoring devices The stainless steel burst disc will rupture within 10ms at 1530kPa 222psi 10 and has a fatigue life of 100 000 cycles to 90 maximum pressure PRESSURE CERTIFICATE WORKS 15802 0 15400 4 with a 15450 3 Control Unit and two 15802 0 Oxidation Vessels installed ACCESSORIES Oxidation Stability Console Bath 15802 0 SETA OXIDATION VESSEL with mandatory burst disc as required by ASTM D525 D873 IP 40 amp IP 138 for details see below left PRESSURE CERTIFICATE UKAS 15803 0 SETA VESSEL CLAMP to hold vessels during opening and closing can be bench mounted 15805 0 SPANNER for oxidation ve
19. SETA SAMPLING TUBE A quick and easy method of drawing samples from drums barrels cans or tank wagons to within 600ml capacity 3mm of the bottom of the vessel Comprises a 600ml capacity tube manufactured from tough transparent perspex and capped at either 0 9 metres long I i I end by bonded in perspex plugs 6mm diameter holes allow sampling and venting and the bottom plug Perspex has a conical internal profile to allow sediment to collect when the tube is held vertically DIP TAPES AND WEIGHTS TAPES AND WEIGHTS 14940 0 DIP TAPE AND FRAME ASTM D1085 FTM 791 8003 SPECIFICATIONS 30 metre steel tape Graduated in m cm mm IP M8 Roo dis rune O A 30 metre reel of 13 mm wide hardened and tempered carbon steel tape graduated in metres centimetres and millimetres mounted in a brass frame with a carrying handle and a folding winding handle Note Requires a dip weight TORPEDO SHAPED DIP WEIGHTS Graduated in cm mm IP M10 14940 0 and 14460 0 15cm length Seta Part Weight Application 14420 0 0 7kg Light oils Brass 14460 0 1 5kg Heavy oils WATER ULLAGE RULES TANK TEMPERATURE SAMPLING 14620 0 14620 0 WATER FINDING RULE 07520 0 ASTM IP TANK SAMPLING THERMOMETER CASE Detects water under black oils crude and heavy fuels Used with marker pastes and dip tape to monitor depths Typical immersion times 20 to 60 seconds according to the product being tested 100ml sa
20. SETAVIS KAV AUTO DUPLEX TUBES 83620 0 KINEMATIC VISCOSITY BATH THERMOMETER 83622 0 KINEMATIC VISCOSITY BATH THERMOMETER 83624 0 KINEMATIC VISCOSITY BATH THERMOMETER 83626 0 KINEMATIC VISCOSITY BATH THERMOMETER 83630 0 BITUMEN ACCESSORY KIT 83631 0 KINEMATIC VISCOSITY BATH THERMOMETER 83633 0 KINEMATIC VISCOSITY BATH THERMOMETER 83640 0 KINEMATIC VISCOSITY BATH THERMOMETER 83641 0 KINEMATIC VISCOSITY BATH THERMOMETER 83700 5 UNIVERSAL PRE HEATING AND FILTERING KIT 83710 0 HYPODERMIC SYRINGE pack of 10 83747 2 DIGITAL PIPETTE 83748 2 PIPETTE TIPS pack of 200 83750 3 SETATIME SIX CHANNEL QUARTZ TIMER 84000 0 KV 8 VISCOMETER BATH 84001 0 DIFFUSED LIGHTING UNIT 84002 0 TOP PLATE KV8 84003 0 COVERS pack of 2 84004 0 CAPS 84005 0 SPIRIT LEVEL 84006 0 UNIVERSAL THERMOMETER HOLDER 84008 0 BENCH VISCOMETER STAND 84102 0 DENSITY MEASURING KIT 84200 0 KV 6 VISCOMETER BATH 86000 3 PORTABLE OIL CONDITION TEST KIT 86000 301 WATER IN OIL REAGENT PACK A amp B 50 tests 86200 0 BIODIESEL TEST KIT 86300 0 LEAD IN GASOLINE TEST KIT 86400 2 PORTABLE FUEL INTEGRITY TEST KIT 86500 001 SHELL WATER CAPSULES pack of 160 86500 2 SSAFPAK AVIATION FUEL CONTAMINATION TEST KIT 87500 0 PROTECTIVE ARMOUR THERMOMETER CASE 87510 0 PROTECTIVE ARMOUR THERMOMETER CASE 87520 0 ASTM IP TANK SAMPLING THERMOMETER CASE 87530 0 LAB HOLDER 90000 3 OIL TEST CENTRIFUGE 90001 2 ADAPTOR pack of 4 90002 0 ADAPTOR pack of 4 90003 2 ADAPTOR pack o
21. e IN BUILT SAFETY 3 independant hardware safety systems Fire sensors over temperature protection and automatic gas shut off Automatic sample bath fluid and probe checks prior to heating Integral software limits Suitable for unattended operation Pensky Martens D93 10 C safety protocol RANGE OF ACCESSORIES Clear draught screens Printer Remote alarm system Rapid cooling modules amp cryostats Calibration and verification instruments and materials Flash Point Smoke Point amp Sustained Burning MODULAR FLASH POINT TESTER MULTIFLASH PENSKY MARTENS CLOSED CUP MODULE 34100 2 ASTM D93 E502 IP 34 IP 404 obs BS 2000 Parts 34 amp 404 obs ISO 15267 EN ISO 2719 JIS K2265 NF M07 019 DIN 51 758 FTM 791 1102 EPA 1010A GB T 261 Procedures A B and C Flexible automated search mode Ambient to 400 C temperature range Gas or electric ignition Independent fire detector The Pensky Martens Closed Cup Module comprises a Test Area DIPS pod Dipping Ignition Pilot Stirrer flash detector sample temperature probe and all necessary cables to interconnect with the 34000 0 Universal Base Unit The Test Area consists of an electrically heated solid block air bath with a removeable sample cup and lid The lid is equipped with a stirrer rotating shutter and ports for the flash detector and sample temperature probe The DIPS pod contains a fire detection probe stirrer drive shutter actuator and
22. 1 A SETAPLUS EXTENDED WARRANTY AVAILABLE ACCESSORIES Roll Stahility Tester SPECIFICATIONS REQUIRED Up to 4 cylinders 19401 0 THERMOMETER AND COLLAR ASSEMBLY Rotational Speed 10 or 165 RPM 19420 0 CYLINDER mild steel with threaded end cap and smooth finished interiors Temperature Range Ambient to 150 C 19430 0 ROLLER 5kg 500 for use in Seta 19420 0 one required for each cylinder 110 120V 60Hz OPTIONAL 220 240V 50Hz 99100 2 ANALYTICAL BALANCE for details see page 141 1 4kW r Size HxWxD CALIBRATION VERIFICATION amp TRAINING Weight 99927 0 DIGITAL THERMOMETER WITH INTERCHANGEABLE PROBES for details see page 130 99960 0 DIGITAL PHOTO TACHOMETER for details see page 147 Note Other items which may be required include Solvent 64 Oxidation ROBOT BATH 15200 5 15210 5 15210 5 Oxidation stability SETA RoBOT BATH ASTM 02112 02272 D4742 IP 229 Ambient to 160 C 2 test stations Fume extraction Gear drive Optional automatic pressure monitoring A floor standing unit used for the evaluation of oxidation stability of new and in service engine turbine and insulating oils in the presence of water and a copper catalyst Up to two oxidation test vessels 15210 5 are supported at an angle of 30 in an oil bath and rotated at 100 rev min by an electric motor and bevel gear drive The 72 litre oil bath
23. 150 mesh 5 packs of 500g 11490 0 GLASS SUPPORT CRADLE to hold silver token for D4814 pack of 3 11500 0 COPPER CORROSION TEST VESSEL for copper tests on natural gasoline and aviation fuels Stainless steel with 0 ring sealed screw top closure Max working pressure 690kPa 100psi PRESSURE CERTIFICATE WORKS 11510 0 SILVER CORROSION CONVERSION KIT adapts 15550 0 for silver corrosion test Comprises six support rings water manifold clips and tubing 11514 0 TONGS 150mm long stainless steel for sample handling 11515 0 SILVER CORROSION TEST KIT GASOLINE for details see page 77 11520 0 TEST TUBE EJECTOR SPRING to aid removal of test tube from corrosion vessel Required for D4814 only 11530 0 SETA MULTI STRIP VICE holds up to five strips while polishing 11550 0 COPPER TEST STRIP 99 9 Cu pack of 30 for details see below 11570 0 FLAT GLASS TEST TUBE to protect strip during inspection pack of 10 11580 0 COPPER STRIP CORROSION STANDARD a set of 13 plaques printed on aluminium and encapsulated in plastic for protection 11590 0 TEST TUBE 25 x 150mm pack of 10 22750 2 DIGITAL STOPWATCH 0 1s resolution for details see page 141 94632 0 SILICONE BATH OIL 20 litres for filling bath for temperatures between 100 and 150 C Note 1 required for 11305 0 2 required for 15550 0 or 11400 6 94633 0 BATH OIL 20 litres for filling bath for temperatures up to 80 C Note 1 required for 1
24. 61 63 100 63 100 100 82 82 82 99 98 98 Part Number 19800 010 19800 011 19800 013 19800 014 19800 016 19800 017 19800 018 19800 019 19800 020 19800 021 19800 022 19800 024 19800 025 19800 026 19800 034 19800 035 19800 036 19800 213 19800 227 19810 001 19910 001 19910 0 19910 001 20290 4 20290 301 20410 0 20400 001 20480 012 20460 0 11870 003 20460 002 20460 003 20460 004 20470 5 20470 501 21560 302 21560 303 20490 0 20100 001 20480 001 20480 002 20480 003 20480 004 20480 006 20480 007 20480 008 20480 009 20510 4 20470 501 21560 302 21560 303 20800 0 11730 203 11730 204 20480 009 20850 001 20850 004 20850 005 20900 0 20900 001 20900 002 20950 0 20950 001 20980 0 20400 001 20990 001 20990 003 20990 0 20990 001 20990 003 21200 0 21200 001 21200 002 21200 003 21200 004 21200 005 21200 006 21300 0 21300 001 21300 002 21300 003 21400 0 Nut Locking Ring Locking Ring Torque Arm wiith Holding Ring Bearing Plate Disc Plunger Head Bearing Plug Bearing Pin Retaining Plate Vee Block Matched Pair Knife Edge Bearing Thrust Race Plunger Head Thrust Race Bearing Hub Ball Race Bearing Hub set of 2 Sliding Cursor Set of Weights Ball Chuck Torque Arm with Holding Ring Bearing Hub amp Ball Holder Housing Ball Race Chart Rolls 19900 2 with 19910 0 fitted Chart Recorder Chart Rolls Air Pump R
25. DEMO LIMAY Operator ID STEVE Test no 000228 Igniter Hire Large Colour Display Flash Point Smoke Point amp Sustained Burning Small Scale Flash Point 1 SETAFLASH SMALL SCALE FLASH POINT 62100 0 SETAFLASH SERIES 8 ACTIVECOOL CLOSED CUP TESTER ASTM D3278 D3828 D7236 E502 IP 523 IP 524 IP 534 ISO 3679 ISO 3680 BS 3900 Part 13 BS 6664 Parts 3 amp 4 UN Class 3 Non viscous Flammable Liquids CHIPS Regulations EPA 1020A amp B 20 to 130 C 4 to 266 F temperature range Ag Small sample size 2 or 4ml Flash No Flash amp Ramp modes Electric ignitor with gas option Automatic dipping and flash detection ActiveCool electronic Peltier cooling 64 Test memory amp RS232 interface C or F temperature display e The Series 8 ActiveCool is an automated closed cup flash point tester with a temperature range of 10 to 130 C 50 to 266 F with no external cooling required When connected to a suitable water supply the range is extended down to 20 C 4 F There are two modes of operation Flash No Flash and Ramp The ramp mode increases the sample temperature at a rate of 2 C min and automatically dips the ignitor every 1 C up to 100 C every 2 C above 100 C until either a flash is detected or the end of test temperature is reached The automatic flash detection system is tuned to ignore halo and other false flash effects enhancing precision and accuracy Barometric pressure is measured
26. F 4 n 1 JA p f 16990 2 70200 0 70210 0 70220 3 SPECIFICATIONS Seta Part No 70200 0 70210 0 70220 3 Pellet Block size 30g 102 500g 1 116 1kg 2 2Ib approx lE Injection Time 1 minute 2 minute 1 minute approx P PR Size HxWxD 27 x 15 9 28x 15x 15cm 23x15x 12cm Weight 0 6kg 0 8kg 3 3kg 3091033 Freezing Point Cold Flow amp Freezing Point FREEZING POINT SETA FREEZING POINT APPARATUS ASTM D2386 IP 16 ISO 3013 NF M07 048 FTMS 791 1411 JIS K2276 Detects solid hydrocarbon crystals Reference method 24680 2 Comprises sample tube paddle unsilvered flask cork stopper thermometer support and an insulated metal case with a viewing slot CALIBRATION amp VERIFICATION MATERIALS ACCESSORIES Freezing Point Apparatus 16992 0 MOISTURE PROOF COLLAR A type A Nitrogen OR 16993 0 MOISTURE PROOF COLLAR type Dehydrating THERMOMETERS ASTM114C IP14C 24500 0 SETA STEEL STAND with steel support mast 16990 2 24680 2 SETA RECIPROCATING STIRRER with adjustable stroke Voltage 110 120V 60Hz 220 240V 50Hz 7021040 SNOWPACK MAJOR DRY ICE MAKER CALIBRATION VERIFICATION amp TRAINING 99850 0 MULTI TEST VERIFICATION MATERIAL ASTM D2386 IP 16 Kerosine F 24500 0 for details see page 150 SPECIFICATIONS Size HxWxD 50 x 25 x 25cm Weight 3 5kg Typical Freezing
27. Gas Supply gas jet ignitor Laboratory gas 3kPa 0 44psi maximum pressure Water 5 C and above Water Ethylene Glycol 50 50 below 5 C 125kPa 18psi maximum pressure Cooling Supply Voltage 110 120V or 220 240V 50 60Hz switchable Power TkW Size HxWxD 42 x 45 x 34cm Weight i 20kg Flash Point Smoke Point amp Sustained Burning MODULAR FLASH POINT TESTER x 34400 0 mounted on 34000 0 with 34011 0 Draught Screen E i ENA CALIBRATION amp VERIFICATION MATERIALS SETALERT COMPATIBLE TECHNICAL DATASHEETS AVAILABLE 34008 0 81002 2 60005 002 99880 0 99910 0 34100 001 34400 002 34400 003 34400 005 81002 001 CONSUMABLES TAG Closed Cup Module ACCESSORIES TAG Closed Cup Module COOLING BOOST MODULE SETALERT REMOTE PAGING SYSTEM SPIRIT LEVEL RS232 CABLE for connecting instrument to PC CRYOSTAT 20 C SHUTTER LUBE DRAUGHT SCREEN recommended for gas tests PRINTER DRY WELL PROBE CALIBRATOR for details see page 147 FLASHCHECK secondary verification material for details see page 156 PORTABLE DIGITAL BAROMETER 750 to 1500 mbar absolute for details see page 145 SUAS Gr DEV ECHO cocto dc e LEE EL E NN C 2 SAMP E e ama E aa 1 BAT HIPA PROBES Wa eed d E 1 GD AXIADIGNITOR Se ur EU TI EP UC 2 PRINTER PAPER pack of 20 rolls 1 Flash Point Smoke P
28. Post Test Cool down Time 45 minutes Fan 90 C to 50 C 3 minutes external cryostat Ignitor Quick fit coaxial gas jet electric hot wire user selectable Electric hot wire pilot light for gas jet Temperature Probes Class A Platinum Resistance Thermometers Flash Detection Thermocouple Stirrer Speed 30 rpm Gas Supply gas jet ignitor Laboratory gas 3kPa 0 44psi maximum pressure Cooling Supply Water 5 C and above Water Ethylene Glycol 50 50 below 5 C 125kPa 18psi maximum pressure Voltage 110 120V or 220 240V 50 60Hz switchable Power 600W Size HxWxD 47 x 45 x 34cm Weight 13kg Flash Point Smoke Point amp Sustained Burning MODULAR FLASH POINT TESTER 34200 0 mounted on a 34000 0 Base Unit with a 34012 0 Draught Screen fitted CALIBRATION amp VERIFICATION MATERIALS SETALERT COMPATIBLE E TECHNICAL DATASHEETS AVAILABLE OOC ACCESSORIES Abel Closed Cup Module 34008 0 COOLING BOOST MODULE 00100 0 SETALERT REMOTE PAGING SYSTEM 23680 0 SPIRIT LEVEL 34003 0 RS232 CABLE for connecting instrument to PC 34006 0 CRYOSTAT 20 C 34007 0 SHUTTER LUBE 34012 0 DRAUGHT SCREEN recommended for gas tests 81002 2 PRINTER 60005 002 DRY WELL PROBE CALIBRATOR for details see page 144 99850 0 MULTI TEST VERIFICATION MATERIAL IP 170 Kerosine for details see page 150 99910 0 PORTABLE DIGITAL BAROMETER 750 to 1500 mbar absolute for details
29. STANHOPE SETA ui Biofuels Petroleum feedstock Crude oil Chemicals Lubricants Cosmetics Paints and varnishes Bitumens Recycled product Laboratory instruments for quality control analysis and calibration STANHOPE SETA www stanhope seta co uk Laboratory instruments for quality control analysis and calibration Stanhope Seta design and manufacture quality control instruments used to measure the physical characteristics that determine product quality and consistency Seta instruments are used by many diverse industries including oil refining petrochemical lubricants pharmaceutical food cosmetics plastics and transport X SersAnelulics www seta analytics com Analytical solutions for hydrocarbon petroleum products Seta Analytics provide analytical solutions for Hydrocarbon Petroleum products Itis a division of Stanhope Seta which combines long established experience of testing petroleum products with the latest measurement technologies to provide enhanced analytical solutions for exploration refining petrochemical distribution and marketing operations Current developments include laser based measurement for particle counting electrochemical sensors for H2S detection and miniature FTIR technology for low level detection of FAME in Jet Fuels seta biofuel testing www biofueltesting com Test instruments for biofuels analysis Many Seta instruments are suitable for testing bio fuels i
30. Seta Part No Seta Part No Temperature Temperature Works Cert UKAS Cert Set Point C Range C 83631 0 83631 04 60 58 6 to 61 4 83633 0 _83633 02 135 133 6 to 136 4 sales stanhope seta co uk www stanhope seta co uk 35 Viscosity 84000 0 KINEMATIC VISCOMETER BATHS Kinematic Capillary SETA KV 8 VISCOMETER BATH ASTM D445 D446 D2170 D2270 IP 71 IP 226 IP 319 BS 188 BS 2000 Parts 71 amp 319 EN 3104 EN 12595 ISO 3105 DIN 51 366 DIN 51 562 FTM 791 305 NF T60 100 NF T60 136 JIS K2283 Up to 8 viscometer tubes 50 litre oil bath Temperature range ambient to 150 C Precision temperature trim control Toughened glass front panel Optional diffused backlight The Seta KV 8 has a 50 litre temperature controlled oil bath that can accommodate up to eight standard viscometer tubes Digital temperature control and an inbuilt cold water cooling coil provide accurate and stable test temperatures from ambient to 150 C 0 01 C below 100 C and 0 03 at 150 C The bath is protected by low liquid level and overtemperature cut outs Equipped with a toughened glass front window easily accessible drain valve levelling feet and with provision for fitting diffused back lighting top plate and attachments SUPPLIED WITH mains lead and instruction manual Ambient to 150 C 0 01 up to 100 C 30 03 at 150 C Temperature Uniformity 0 01 40 and 100 C
31. Supplied in 50ml containers Setaflash certified flash point materials are suitable for Closed Cup test methods and are manufactured in accordance with ISO Guides 34 and 35 Reproducibility is in accordance with ISO 4259 Nominal certified flash point value 74 C uncertainty 0 3 C Supplied in 50m bottles CERTIFICATE OF MEASUREMENT WORKS FLASH POINT VERIFICATION STANDARDS 99880 0 99882 0 99883 0 99884 0 SETA FLASHCHECK Cleveland ASTM D92 86 C flash point nominal Pensky Martens ASTM D93 75 flash point nominal TAG ASTM D56 74 C flash point nominal TAG Open Cup ASTM D1310 82 flash point nominal Supplied in 80ml containers pack of 3 Flashcheck is a highly cost effective and non hazardous Secondary Working Standard suitable for verification of ASTM CEN ISO IP and equivalent flash point testing procedures Flashcheck provides rapid validation of test results and verification of inter company cross check schemes it is also a useful material for operator training and checking instrument performance CERTIFICATE OF MEASUREMENT WORKS FOR ALL 4 TEST METHODS E WW TECHNICAL DATASHEETS AVAILABLE CLEVELAND STANDARD 3 PACK CLEVELAND STANDARD 6 PACK CLEVELAND STANDARD 12 PACK Fully traceable to National Standards Tested and certified in accordance with ASTM D92 IP 36 258 C nominal value Supplied in 80ml bottles Designed specifically for use in determining
32. Temperature Range Temperature Stability Tube Capacity up to 8 Bath Fluid Bath Capacity 50 Litres Voltage 220 240V 50 60Hz ai Power 3 1kW Size HxWxD 60x 79 x 35cm Weight 44kg EE ACCESSORIES KV 8 TA TI REQUIRED iL TAG qa 9 LI ee u BR RR KINEMATIC VISCOMETER TUBES Select from the tables on pages 40 to 42 SETA KINEMATIC VISCOSITY BATH THERMOMETERS With ice point scale and 0 02 C subdivisions to allow easy reading to within 0 01 C CALIBRATION CERTIFICATE WORKS CALIBRATION CERTIFICATE UKAS OPTIONAL Seta Part No Seta Part No Temperature Temperature Works Cert UKAS Cert Set Point Range 83640 0 83640 0Z 40 38 6 to 41 4 83641 0 83641 07 100 48 6 to 51 4 23150 2 UNIVERSAL VISCOMETER HOLDER for all regular viscometer tubes 8 required 84002 0 PLATE KV8 with levelling screws for each position accepts eight viscometer tube holders and two thermometers 84006 0 UNIVERSAL THERMOMETER HOLDER 2 required 94633 0 BATH OIL 20 litres for filling viscometer baths in the temperature range of ambient to 80 3 required OR 94635 0 BATH OIL 20 litres for filling viscometer baths in the
33. mu 114C 14C Aviation Fuel Freezing Point 80 to 20 C 0 5 C total 300 74F 69 Kinematic Viscosity 67 5 to 62 5 F 0 1 F total 305 116C Bomb Calorimeter 18 9 to 25 1 C 0 01 C total 609 155 Anti freeze Freezing Point 35 to 35 F 0 5 F 100 408 117 Bomb Calorimeter 23 9 to 30 1 C 0 01 C total 609 76F Anti freeze Freezing Point 65 to 5 F 0 5 F 100 408 EA 118C Kinematic Viscosity 28 00 to 31 4 C 0 05 C total 305 Saybolt Viscosity 245 to 265 F 0 5 F total 275 118 Kinematic Viscosity 83 5 to 88 5 F 0 1 F total 305 78F Saybolt Viscosity 295 to 315 F 0 5 F total 215 119 Anti freeze Freezing Point 38 3 to 30 C 0 1 C 100 420 79F Saybolt Viscosity 345 to 365 F 0 5 F total 215 119 Anti freeze Freezing Point 37 to 22 F 0 2 F 100 420 80F Saybolt Viscosity 395 to 415 F 0 5 F total 275 n 120 92 Kinematic Viscosity 38 6 to 41 4 C 0 05 C total 305 81F Saybolt Viscosity 445 to 465 F 0 5 F total 215 EUM 121 32C Kinematic Viscosity 98 6 to 101 4 C 0 05 C total 305 82C Fuel Rating Engine 15 to 105 C 1 C 30 162 122C 94C Brookfield Viscosity 45 to 35 C 0 1 C total 300 82F Fuel Rating Engine 0 to 220 F 2 F 30 162 i f r 123C 95C Brookfield Viscosity 35 to 25 C 0 1 C 300 83C Fuel Rating Air 15 to 70 C 1 C 40 171 124 96 Brookfield Viscosity 2
34. 0 1 C accuracy at 150 C SUPPLIED WITH block extractor tool mains lead and instruction manual Over temperature cut off External temperature probe for in block or in sample f measurement BIO FUEL TESTING Function timer for delayed start stop 1 min 72 hours Audible end of test buzzer SPECIFICATIONS SPECIFICATIONS ____ O sarn m mma p ma Voltage 110 120V 50 60Hz 110 120V 50 60Hz 110 120V 50 60Hz 110 120V 50 60Hz 110 120V 50 60Hz m Er sr ia _ Wu SS Corrosion amp Rust Corrosion Test Kits amp Strips COPPER amp SILVER CORROSION BATHS amp SILVER CORROSION BATHS ACCESSORIES Copper amp Silver Corrosion Baths REQUIRED Select from the table ITEMS REQUIRED FOR EACH TEST 11241 0 SILICONE CARBIDE PAPER 105um 150 grit FEPA 28 x 23cm pack of 50 11420 0 SUPPORT for copper tests except natural gasoline and aviation fuels Holds three test tubes in bath pack of 2 11430 0 SILVER CORROSION GLASSWARE comprises amber glass oil test tube cold finger condenser with glass hook for test strip and glass cradle 11440 0 SILVER TEST STRIPS 99 9 Ag pack of 5 for details see below 11450 0 ASTM COLOUR STANDARD ASTM D1660 D3241 IP323 11460 0 SILICONE CARBIDE PAPER 65um 240 grit FEPA 28 x 23cm pack of 50 11470 0 SILICONE CARBIDE PAPER 100 grit FEPA 28 x 23cm pack of 50 11480 0 SILICONE CARBIDE GRAINS 105
35. 0 1 C total 215 18F 23 Reid Vapour Pressure 94 to 108 F 0 2 F total 275 EO MEL LA ARAM n 56F Bomb Calorimeter 66 to 95 F 0 05 F total 600 19C Saybolt Viscosity 49 to 57 C 0 1 C total 275 Tap Closed Cun Tester tow 19F Saybolt Viscosity 120 to 134 F 0 2 F total 275 57C Range 20 to 450 OSC 57 287 20C Saybolt Viscosity 57 to 65 C 0 1 C 275 5 Tag Closed Tester 4 to 122 F 1 F 57 287 20F Saybolt Viscosity 134 to 148 F 0 2 F total 215 58C Tank 34 to 49 C 0 5 C total 305 58F Tank 30 to 120 F 1 F total 305 216 Saybolt Viscosity 79 to 87 0 1 C total 275 59 Tank 18 to 82 C 0 5 C 305 21F Saybolt Viscosity 174 to 188 F 0 2 F total 275 59F Tank 0 to 180 F 1 F total 305 22C 24C Oxidation Stability 95 to 103 C 0 1 C total 215 22F 24F Oxidation Stability 204 to 218 F 0 2 F X total 275 60C Tank 77 to 260 C 1 C total 305 23C Engler Viscosity 18 to 28 C 0 2 C 90 212 60F Tank 170 to 500 F 2 F total 305 24C Engler Viscosity 39 to 54 C 0 2 C 90 237 61C 63C Petrolatum Melting Point 322 0 2 C 79 380 25C Engler Viscosity 95 to 105 C 0 2 C 90 212 61F Petrolatum Melting Point 90 to 260 F 0 5 F 79 380 26C stability Soluble 130 to 140 C 01 C total 463 62C Precision 38 to 2 C 0 1 C total 379 Nitrocellulose 62F Precision 36 to 35 F 02 F total 379 27C Turpentine Distillation 147 to 182 C 0 5 C 76 301 6
36. 07 045 rs 84 NF M070A r aaa 73 NF MOZDA ruas 32 iim ia NM 86 NFMO07 078 rs 22 23 NF M400 rra 119 123 NF M41007 i aaa 16 77 118 NF 41 008 116 135 NEMAJI 00050000606 24 26 LAUR a aaa 117 LA AN 4 NFET60710 ras 132 133 La 95 NF TG AU asas 112 114 90 51 NF TODI 4 asas 31 56 93 85 AL 85 NF aasan 19 NFT60119 rss 2 6 58 60 NFT60 129 rase 102 103 149 NF TOD T32 38 62 ocna 94 NF 60 136 ass 32 34 36 37 LA 58 NF 160 148 rss 84 NF 60 150 asse 10 72 73 idi MEME 78 NFT66 003 obs s 31 NFET66 004 55s 58 60 NFT66 008lobs s 54 prEN 609702006 e 80 RINA Non combustibility C ss TOCTS861 00 1S SABS 555 119 SAE749D 50 81 81 SAE 58 5s 81 STPTC PIS Cs 54 UNClass3 2 8 10 13 15 156 UNClass3TestE2 r 16 UN Class 4 Division 4 1 c 2 US Department of Transport 21 40 173 gt VDE 0370 115 Flash Point Smoke Point amp Sustained Burning Multi Method Flash Point 1 MODULAR FLASH POINT TESTER fam MULTIFLASH AUTOMATIC MULTI METHOD FLASH POINT TESTER PENSKY MARTENS ABEL TAG CLEVELAND amp SMALL SCALE Multiflash is a universal fully automated instrument designed for testing the flash point of fuels lubricating oils solvents chemicals waste materials and many other substances The instrument c
37. 14866 2 WINDER for details see page 121 A valve at the bottom of the universal sampler is actuated by an adjustable bottom sensor allowing true bottom sampling between 1 and 35 cm above the bottom of the bulk container The valve at the top of the sampler is actuated by a snatch cord and latches in the open position A Top Hat prevents the liquid running down the line from contaminating the contents of the sampler UNIVERSAL SAMPLERS Sampling Range Length Seta Part Capacity height from bottom Diameter probe retracted Weight Material 14875 0 500ml 1 to 20cm 6 4cm 34 5cm 2kg Stainless steel 14875 0 14876 0 500ml 1 to 20cm 6 4cm 34 5cm 2kg Brass Bottom Valve 14877 0 1 litre 1 to 35cm 6 4cm 52cm 2 5kg Stainless steel MULTI LEVEL SAMPLERS Snatch cord opening ACCESSORIES Multi Level Samplers Valve latches open OPTIONAL Top Hat prevents sample contamination 14866 2 WINDER for details see page 121 MULTI LEVEL SAMPLERS Valve Throat Seta Part Capacity Diameter Diameter Length Weight Material 14851 0 450ml 2 1cm 3 8cm 55cm 1 1kg Brass 14852 0 450ml 2 1cm 3 8cm 55cm 1 1kg Stainless steel 14854 0 500ml 2 3cm 5 0cm 43cm 1 5kg Stainless steel 14857 0 1 litre 3 1cm 6 4cm 48cm 2 2kg Brass 14858 0 1 litre 3 1cm 6 4cm 48cm 2 2kg Stainless steel 14859 0 2 5litre 4 0cm 10 2cm 50 Akg Stainless steel 14851 0 14854 0 14858 0 14859 0 MULTI LEVEL SELF SEALING SAMPLERS ACCESS
38. 227 C ASTM IP amp Non Mercury Thermometers Temperature amp Fluid Density IP THERMOMETERS THERMOMETERS QAN CONFORMANCE CERTIFICATE To order a thermometer with a works conformance certificate quote the IP or ASTM part number i e IP39C 7 CALIBRATION CERTIFICATE UKAS 7o order a thermometer with a UKAS calibration certificate add the suffix Z to the IP or ASTM part number i e IP39CZ IP THERMOMETERS IP APPENDIX 1 ASTM APPLICATION TYPE RANGE 85C 104C Solvents Distillation 173 to 227 C 86C 105C Solvents Distillation 198 to 252 C 87C 106C Solvents Distillation 223 to 277 C 88C 107C Solvents Distillation 248 to 302 C 89C 113C Softening Point Wide Range 1 to 175 C 89F 113F Softening Point Wide Range 30 to 350 F 1 F 90C 48C Kinematic Viscosity 82 2 C to 83 4 C 0 05 90F 48 Kinematic Viscosity to 182 5 F 91C Rapid Flash Point to 110 C 1 C 92C 120C Kinematic Viscosity 40 C to 41 4 C 0 05 93C 110C Kinematic Viscosity 135 C to 136 4 C 0 05 C 94C 122C Brookfield Viscosity to 35 C 0 1 C 95C 123C Brookfield Viscosity to 25 C 0 1 C 96C 124C Brookfield Viscosity to 15 C 0 1 C 97C 125C Brookfield Viscosity to 5 C 0 1 C 98C Rapid Flash Point High to 300 C 2 C 99C 127C Kinematic Viscosity 20 C to 18 6 C 0 05 Kinematic Viscosity 80 C 81 4 C 0 05 Medium Pensky Martens 150 C 1 C 132C Kinematic
39. 50 60Hz Size HxWxD 6x 34x 32cm Weight 3kg Note Flexible ducting is not supplied raiirin TARAIA AT Vent tube 50mm outside diameter Voltage 110 120V 50 60Hz 220 240V 50 60Hz Size HxWxD 52x 52 40cm Weight 8kg Flash Point Smoke Point amp Sustained Burning CLEVELAND OPEN CUP FLASH POINT z 13811 3 Thermometer supplied separately 1 1 D m Ww RN wu E B y Temperature range Ambient to 400 C Power I 600W maximum Ramp Rate Variable manually controlled Voltage 110 120V 50 60Hz 220 240V 50 60Hz Size HxWxD 33 x 31 x 29cm Weight 6 5kg CONSUMABLES Cleveland 13730 005 SILICONE RUBBER TUBE 4 metres 1 1880000 A ES c 1 13663 0 71001 0 Flash Point Smoke Point amp Sustained Burning Smoke Point SETA SMOKE POINT APPARATUS ASTM D1322 IP 57 BS 2000 Part 57 ISO 3014 NF M07 028 SPECIFICATIONS Size HWD 47 21 x 18cm 10400 0 10425 0 Robust construction Clearscale An instrument for determining the smoke point of kerosine and aviation turbine fuel by measuring the maximum flame height prior to smoke formation and comparing the results with those of known standards The smoke point gives an indication of aromatic content and radiant h
40. 60 F API Gravity 56HH 12381 06 49 to 61 60 to 220 F Gr Thermo 12356 08 35 to 41 Short 60 F Gravity 57HL 12382 07 59 to 71 0 to 150 F Gr Thermo 12356 09 40 to 46 Short 60 F API Gravity 57HM 12383 07 59 to 71 30 to 180 F Gr Thermo 12356 10 45 to 51 Short 60 F API Gravity 57HH 12381 07 59 to 71 60 to 220 F Gr Thermo 12356 11 50 to 56 Short 60 F API Gravity 58HL 12382 08 69 to 81 0to 150 F Gr Thermo 12356 12 55 to 61 Short 60 F API Gravity 58HM 12383 08 69 to 81 60 to 220 F Gr Thermo 12356 13 60 to 66 Short 60 F API Gravity 58HH 12381 08 69 to 81 60 to 220 F Gr Thermo 12356 14 65 to 71 Short 60 F API Gravity 59HL 12382 09 79 to 91 0 to 150 F Gr Thermo 12356 15 70 to 76 Short 60 F API Gravity 59HM 12383 09 19 to 91 30 to 180 F Gr Thermo 12356 16 75 to 81 Short 60 F API Gravity 59HH 12381 09 19to 91 60 to 220 F Gr Thermo 12356 17 80 to 86 Short 60 F API Gravity 60HL 12382 10 89 to 101 0to 150 F Gr Thermo 12356 18 85 to 91 Short 60 F API Gravity 60HM 12383 10 89 to 101 30 to 180 F Gr Thermo 12356 19 90 to 96 Short 60 F API Gravity 60HH 12381 10 89 to 101 60 to 220 F Gr Thermo 12356 20 96 to 101 Short 60 F Gravity 12351 01 12351 02 12351 03 12351 04 12351 05 12351 06 12351 07 12351 08 12351 09 12351 10 0 600 to 0 650 0 650 to 0 700 0 700 to 0 750 0 750 to 0 800 0 800 to 0 850 0 850 to 0 900 0 900 to 0 950 0 950 to 1 000 1 000 to 1 050 1 050 to 1 100 Long 60 F Long 60 F Long 60
41. ASTM D2386 ASTM D130 ASTM D323 ASTM D5191 ASTM D873 Fuel Oil Bio Heating ISO 8217 Fuels EN 14213 ISO 3675 150 3675 IP 160 IP 160 ISO 2719 ISO 3679 IP 34 IP 523 524 EN 116 IP 309 ISO 3016 ISO 3016 IP 15 IP 15 ISO 3104 o i ISO 3105 IP 71 ISO 10370 ISO 10370 IP 398 IP 398 EN 15195 IP 498 ISO 3733 IP 74 ISO 10307 IP 375 150 3987 IP 570 Bio Auto Fuels EN 14214 ISO 3675 IP 160 ISO 3679 IP 523 524 ISO 3104 IP 71 ISO 2160 IP 154 150 10370 IP 398 EN 15195 IP 498 150 3987 Bio Fuel Blend Stock B100 ASTM D6751 ASTM D3828 D2500 D445 D130 D4530 ASTM D6890 D2709 ASTM D874 Feature Products HS Analyser Setaflash Series 8 FIJI Fame in Jet TOST Baths COMPOSITION P88 FLASHPOINT P11 COMPOSITION P89 OXIDATION P72 Measurement of 5 in Automatic small scale Rapid screening method to Range of 6 and 12 way solid liquid petroleum products flashpoint testing analyse jet fuels block and oil baths Multi Filtration Tester FLASHPOINT P2 VAPOUR PRESSURE P23 FILTER BLOCKING TENDENCY P83 PARTICULATES P81 Multi mode automated Rapid automated vapour Portable testing for the Laser based particle counter flashpoint testing pressure testing filterability blocking tendency for aviation fuel biodiesel gasoline and diesel Ignition Quality Tester Cloud amp Pour Cryostat Seta Centrifuge Setaflash Series 3 CETANE P110 CLOUD amp POU
42. BATHS BITUMEN BENCH STAND DYNAMIC FLOW CUPS VISCOSITY STANDARDS GENERAL PURPOSE JET FUEL JF1 LOW TEMPERATURE VOLUME METER WATER Page 41 62 71 128 130 86 104 104 63 100 128 18 126 127 127 128 35 37 122 128 35 37 138 86 141 148 26 122 61 142 146 136 117 22 25 22 23 102 103 149 150 151 152 153 79 92 32 39 44 46 33 49 154 32 35 46 4 34 37 32 39 44 46 34 35 46 36 37 32 39 4 48 154 48 154 48 154 97 102 Subject Page BATH CIRCULATING 104 138 139 DEAN amp STARK METHOD 31 FINDING PASTE amp RULE 122 OIL CONTENT 95 96 PURIFIER 61 66 68 76 87 102 137 SEDIMENT 108 109 SEPARABILITY 103 105 VAPOUR DEW POINT METHOD 117 WASHOUT CHARACTERISTICS 100 WAX MELTING POINT 56 PENETRATION 58 59 WEAR LOADING KIT 98 WEIGHTS CERTIFIED 141 147 WHEEL BEARING GREASES 63 100 WICK EXTRACTION APPARATUS 20 WICK TRIMMER 20 WINDERS 121 ZAHN CUPS 47 ZEITFUCHS VISCOMETERS 41 Terms and conditions 1 General All quotations are made and orders accepted by Stanhope Seta in accordance with the following Terms Should you find any matters about which you are not happy please tell us and we will do our best to resolve any queries 2 Specifications Published specifications and product details are subject to amendment as a result of necessary or desirable updating or improvement If these are considered to be of consequence we shall
43. DE SETA SEMI AUTOMATIC TAG OPEN CUP TESTER ASTM D1310 D3413 Ambient to 93 C temperature range Variable ramp rate Electrically driven sweep arm The 13230 3 comprises an electrically heated liquid bath variable ramp rate controller glass sample cup and a button operated electrically driven sweep arm with test jet The test flame uses either mains gas or can operate from a 13667 0 Portable Gas Tank The case features an integral drip tray and a bath overflow SUPPLIED WITH instruction manual and mains lead V CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE ACCESSORIES TAG Flash Point Testers REQUIRED 13740 0 SETA THERMOMETER FERRULE AND ADAPTOR to mount thermometers pack of 2 THERMOMETERS ASTMSC IP15C or ASTM57C ASTMSC IP15C or 20 or ASTM35C IP59C OPTIONAL 13666 0 BUTANE REFILL CONTAINER pack of 10 E EC 13667 0 PORTABLE GAS TANK with on off switch regulator and ignitor Suitable for use with Butane refill 13666 0 containers SETA VENT portable fume extractor and draught excluder excluding flexible ducting PORTABLE DIGITAL BAROMETER 750 to 1150 mbar absolute for details see page 145 45000 0 SETAPLUSEXTENDED 12 MONTH WARRANTY Note Other items which may be required include Ethylene glycol 50ml graduated measure 13220 2 13230 3 71001 0 99910 0 CALIBRATION VERIFICATION amp TRAINING 99880 0 FL
44. Default Values TNCS upita 100 C 13775 0 THERMOMETER 100 to 300 C m _ 2 minutes for flash points between 100 to 300 C 99928 0 SETATHERM digital thermometer 20 to 150 C for details see page 129 Cup Material Blackened Aluminium Voltage 110 120V or 220 240V 50 60Hz switchable CONSUMABLES Setaflash Series 3 Open Cup Tester 12V using optional power supply erm 13730 005 SILICONE RUBBER TUBE 4 2 13740 009 SYRINGE 2ml 1 Size HxWxD 25 6 x 28 x 25 6cm Weight 4kg TAG Flash Point Flash Point Smoke Point amp Sustained Burning POINT 13220 2 13230 3 SETA TAG CLOSED CUP TESTER ASTM D56 D3934 D3941 E502 BS 3900 Parts A8 amp A9 FTM 791 1101 Ambient to 93 C temperature range Variable ramp rate e 500ml Bath The 13220 2 comprises an electrically heated liquid bath variable ramp rate controller metal sample cup and a lid with test jet and shutter The test flame uses either mains gas or can operate from a 13667 0 Portable Gas Tank The case features an integral drip tray and a bath overflow SUPPLIED WITH instruction manual and mains lead 7 CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE
45. Digital temperature control Note Other items which may be required include Dessicator Strainer 100 mesh Bath and Control bulb temperature displays A solid block bath with five test wells digital temperature control and an independent digital thermometer EE FIULATIUNS _ The cast iron block bath is heated by two independent heaters a disk Ambient to 550 C heater in the base and a wrap around band type heater The controls Power 1300W e E for the E ae and the Sidus T Voltage 110 120V 50 60Hz igital thermometer and thermocouple port for measuring control bu 220 240V 50 60Hz temperature are mounted on the front genug Size HxWxD 40 x 42 x 42cm SUPPLIED WITH 10ml syringe stainless steel control bulb thermocouple los EU eight g assembly mains lead and instruction manual e BIO FUEL TESTING CALIBRATION CERTIFICATE WORKS 86 Particulates Residues amp Composition SEDIMENT 16120 2 21300 0 T 44 0 1932 564391 1 44 0 1932 568363 LE sales stanhope seta co uk SETACLEAN TOTAL SEDIMENT TESTER ASTM D4870 IP 375 IP 390 Procedure A ISO 10307 BS 2000 Part 375 NF M07 063 Measures sediment up to 0 5 m m Sample viscosities up to 130mm s 10g sample size Two test stations A compact bench mounted unit for determining the insoluble material content of distillate and residua
46. FLASHCHECK pack of 3 for details see page 156 99960 0 DIGITAL PHOTO TACHOMETER for details see page 147 Weight CONSUMABLES Pensky Martens 2 Years 2000 Tests Qty 13730 005 SILICONE RUBBER TUBE 4 metres 13661 301 PENSKY MARTENS CUP ABEL CLOSED CUP FLASH POINT 13032 3 SETA ABEL FLASH POINT TESTER IP 170 IP 33 obs BS 2000 Parts 33 obs amp 170 ISO 13736 Conforms to the design of the A copper water bath oil cup gas test jet original Abel flash point tester manual stirrer and timing pendulum fitted in a sturdy case 74 and IP 75C thermometers included IP 170 tests SUPPLIED WITH thermometers for the oil cup and water bath and instruction manual ACCESSORIES Abel Flash Point Tester OPTIONAL 13035 0 SETA HEATER ASSEMBLY stainless steel case with halogen lamp heaters 13180 3 SETA ELECTRIC STIRRER for IP 170 Comprises geared stirrer motor flexible drive boss head and stand 13666 0 BUTANE REFILL CONTAINER pack of 10 13667 0 PORTABLE GAS TANK with on off switch regulator and ignitor use with Butane refill container 13666 0 22650 0 SETA ENERGY REGULATOR for heat output control of 13035 0 heater 71001 0 SETA VENT portable fume extractor and draught excluder excluding flexible ducting THERMOMETERS 13140 0 IP74F with collar for tests to IP 33 only pack of 2 13150 0 IP2F with collar for tests to IP 33 only pack of 2 13160 0
47. FLIGHT CASE PC SOFTWARE AvCOUNT SERVICE KIT AvCOUNT TOOL KIT SERVICE AND CALIBRATION AvCOUNT2 EVOCHROM SDA SYSTEM EVOCHROM DIESEL SYSTEM EVOCHROM JET FUEL SYSTEM ESTERCHECK H2S ANALYSER CALIBRATED SENSOR H2S STATIC CALIBRATION KIT H2S PERSONAL PROTECTOR START UP KIT 1 CARRY CASE TEST VESSEL WARMER PC CONNECTIVITY KIT AIRFLOW CALIBRATION VERIFICATION TOOL FIJI FAME IN JET INSTRUMENT FIJI STARTER KIT LOW LINT WIPES pack of 280 FIJI LAPTOP FIJI VERIFICATION FLUID 30ppm FIJI VERIFICATION FLUID 100ppm CALIBRATION MATERIAL SET Product Number Page Index General Subject Page ABEL FLASH POINT TESTER 5 18 ACIDITY TITRATION METHOD 94 ACTIVE COOL FLASH POINT TESTERS 12 ADLAKE BURNING TEST LAMP 21 ADSORPTION APPARATUS FIA TWIN COLUMN 92 AGEING BATH 86 AIR CONDENSER GLASS 86 AIR FLOWMETER CALIBRATED 87 149 AIR PUMPS 136 AIR RELEASE VALUE 104 ALUMINIUM OXIDE CLOTH 78 ANALYTICAL BALANCE 141 147 ANILINE POINT amp MIXED ANILINE POINT 93 ASH CONTENT 84 ASH FURNACE 84 ASPHALT DISTILLATION 31 ASPHALT VISCOMETERS 42 ASPHALTENES 93 AUTO OXIDATION CONTROL UNIT 66 69 AUTOMATIC OIL TESTERS 115 AUTOMATIC PRESSURE MONITORING 65 AVCOUNT PARTICLE COUNTER 80 81 BACON SAMPLING VESSELS 121 BALANCE DENSITY ANALYTICAL 141 147 BAROMETER DIGITAL PORTABLE 145 BAROMETER PRECISION DIGITAL 145 BATH OIL 138 BATHS CLOUD amp POUR POINT 50 51 FOR PENETRATION TEST 61 LOW TEMPERATURE 139 OXIDAT
48. IONISATION RING n 2 34300 002 SAMPLE PAT PROBES Ro 1 8 1002 0 1 PRIN TER PAPER 1 Multi Method Flash Point 34400 0 TAG CLOSED CUP MODULE ASTM D56 D3934 D3941 E502 IP 304 obs Part 2 IP 491 IP 492 ISO 1516 ISO 1523 791 1101 JIS K2265 Equilibrium tests Non Equilibrium tests Flash No Flash tests Flexible automated search mode Ambient to 93 C 5 C to 93 C with optional cryostat Gas or electric ignition The TAG Closed Cup Module comprises a Test Area DIPS pod Dipping Ignition Pilot Stirrer flash detector sample temperature probe bath temperature probe and all necessary cables and pipes to interconnect with the 34000 0 Universal Base Unit and 34008 Cooling Boost Module The Test Area consists of a liquid filled bath with an internal cooling coil a removeable sample cup and lid and an overflow vessel The bath is heated by the hotplate within the 34000 0 Universal Base Unit The cooling coil is connected to the 34008 0 Cooling Boost Module by flexible pipes allowing circulation of water or cooling fluid via a cryostat for sub ambient tests The top of the bath has a port for a temperature probe The lid of the sample cup is equipped with a sliding shutter and ports for the flash detector and sample temperature probe The DIPS pod contains the shutter actuator and ignitor dipping mechanism with a coaxial gas jet electric hot wire ignitor The sample an
49. PORTABLE DIGITAL BAROMETER 750 to 1500 mbar absolute for details see page 145 DIGITAL PHOTO TACHOMETER for details see page 147 CONSUMABLES Pensky Martens Closed Cup Module 4100 001 FLASHIDEIEGTOR 2 002 SAMPLE PRT PROBE 34100 004 CO AXIALIGNITOR 221 81002 001 PRINTER PAPER pack of 20 rolls 1 Multi Method Flash Point 34200 0 MULTIFLASH ABEL CLOSED CUP MODULE IP 170 IP 304 obs Part 2 IP 492 BS 2000 Part 170 BS 3900 Parts A8 and A9 BS 6664 Parts 1 amp 2 EN ISO 13736 ISO 1523 Equilibrium tests Non Equilibrium tests Flash No Flash tests Flexible automated search mode Ambient to 93 C 5 C to 93 C with optional cryostat Gas or electric ignition The Abel Closed Cup Module comprises a Test Area DIPS pod Dipping Ignition Pilot Stirrer flash detector sample temperature probe outer and inner bath temperature probes and all necessary cables to interconnect with the 34000 0 Universal Base Unit The Test Area consists of an outer liquid filled bath surrounding an inner liquid filled bath and a removeable sample cup and lid The outer bath is heated by the hotplate within the 34000 0 Universal Base Unit has a port for a temperature probe and connections for a 34008 0 Cooling Boost Module allowing circulation of cooling fluid via a cryostat for sub ambient tests The inner bath also has
50. Page Mounting Tray 82 Dust Cap Set Oxidation Pres Cyl Norma Hoffman 69 Neoprene Washer pack of 50 Lead Gasket pack of 20 Right Angled Valve Demulsification Apparatus 103 Steam Generator amp Bung pack of 2 Separating Emulsifying Bath pack of 2 Cover for Baths pair Oil Container pack of 2 Set of Tubes amp Tubing Hightemp Bath Universal Oxidation 70 Hightemp Bath 12 Way 71 Band Heater Insulation Kit for Heater Glassware Support Bracket pair Thermal Cut out Probe Nylon Tubing Seal amp Stop Kit pack of 6 Pressure Gauge Regulator Relief Valve amp Cap Temperature Controller Mains Lead Temperature Probe Assembly Connecting Lead Temperature Indicator Glassware 71 Glassware 71 Oxidation Absorption Tube pair 0 Ring to support Adsorption Tube pack of 20 Glassware 71 Silicone Rubber Tubing 5 metres Test Absorption Tube pair 0 Ring to support Adsorption Tube pack of 20 Glassware 71 Sample Tube Sample Head Air Tube Condenser 24 40 Cone Condenser 71 60 Cone Hooks Set of Specimens Oxidation Bath with Oxflo Controller 73 Fuse pack of 5 Heater Power PCB Temperature Probe Stirrer Motor Display PCB Overtemperature Cutout Glassware 72 Glass Condenser Test Tube pack of 2 Oxygen Delivery Tube pack of 2 Freezing Point Apparatus 53 Jacketed Sample Tube pack of 2 Unsilvered Vacuum Flask Brass Packing Gland Stirrer Rod pack of 2
51. Saybolt Universal Chromometer 113 0 Ring Viton pack of 5 Bulb 60W pack of 2 Gasket for Tube pack of 12 High Precision Colorimeter 112 Lamp 5V 100W lens ended Optical Glass Cell 33mm ASTM D1500 Optical Glass Cell 100mm Pt Co Hazen Alpha Saybolt Optical Glass Cell 6 inch IP Units Optical Glass Cell 10mm Gardner Oxidation Stability Console Bath 66 Immersion Heater Thermometer Collar pack of 2 Auto Oxidation Control Unit 67 Pressure Control PCB Pressure Indicator Assembly Transducer Lead for Transducer 0 Ring Viton PTFE pack of 3 Oxi Cor Bath Heater Power PCB Display PCB 67 68 68 74 Part Number 11400 604 16155 303 16155 402 16155 406 15611 0 15610 001 15610 002 15610 003 15610 004 15610 005 15640 001 15650 0 15650 001 15800 4 15800 201 21560 302 21560 401 21810 0 15802 0 15800 201 15801 001 21560 302 21560 401 21810 0 15810 0 15810 001 15810 002 15850 4 15850 002 15850 003 15850 004 50000 001 50000 002 50000 003 50000 004 50000 005 15870 4 15155 006 15155 201 15155 204 16155 303 16155 402 16155 405 16155 406 15880 6 15880 201 15880 202 15881 002 16120 2 16120 001 16120 004 16120 005 16120 006 16120 007 16120 008 16120 009 16120 010 16120 011 16720 002 16125 0 16125 001 16130 3 16130 203 16130 301 16155 4 15155 006 15155 201 15155 204 16155 005 16155 303 16155 402 16155 405 16155 406 16155 407 16160
52. instructions iii if there is any attempt to eliminate a possible or actual malfunction without our consent Please refer to us for specific recommendations iv if SETA instruments are used in conjunction with equipment not recommended by us Please refer v in the case of Accessories or Spares which might be expected to need replacement within the period or vi in the case of anything not of our manufacture Any warranty by manufacturers of instruments apparatus or components supplied to us and capable of assignment will be passed on to our customers under the terms specified In any event Stanhope Seta shall in no circumstances be liable in contract tort including negligence or breach of statutory duty or otherwise howsoever and whatever the cause thereof for any increased costs or expenses any loss of profit business contracts revenues anticipated savings or any special indirect or consequential damage of any nature whatsoever 8 Liability and indemnity Save for liability for death of a human or personal injury arising from Stanhope Seta s negligence our liability for any and all direct loss or damage resulting from defects in product or any other cause shall be limited to a maximum of the purchase price paid for the goods in respect or in relation to which such loss or damage is claimed The customer shall indemnify and hold harmless Stanhope Seta in respect of all damage or injury occurring to any person
53. not conform to the current requirements of ISO 2431 EN535 Formerly required for BS 3900 Section A6 Simple comparative instrument for checking the relative viscosity of batches of viscous fluids 23150 0 23660 0 and 22361 0 Dial Thermometer supplied separately Flow Cup supplied separately Flow Cups X Viscosity Note In the following tables all viscosities and flow times quoted are approximate values at 25 C Cup verification oils are supplied in a 500ml container along with a UKAS calibration certificate FLOW CUP VERIFICATION OIL CALIBRATION CERTIFICATE UKAS Viscosity Range Size Orifice Dia Seta Viscosity Flow Time Seta mm s Code mm Part No mm s seconds Part No 8 to 40 3 3 23560 0 26 2 67 to 70 99890 0 30 to 130 4 4 23550 0 65 5 48 to 53 99891 0 100 to 300 5 5 23540 0 115 35 to 38 99892 0 180 to 700 6 6 23610 0 398 54 to 60 99893 0 600 to 2 000 8 8 23611 0 _ t _ FLOW CUP VERIFICATION OIL CALIBRATION CERTIFICATE UKAS Viscosity Range Jet Orifice Dia Seta Viscosity Flow Time Seta mm s Code inches PartNo mm s seconds Part No 0 to 50 2 0 093 23570 0 65 5 146to 162 99891 0 40 to 120 3 0 125 23580 0 65 5 54 to 59 99891 0 80 to 250 4 0 156 23600 0 115 41 to 45 99892 0 150 to 1 000 5 0 187 23590 0 229 42 to 46 99896 0 100010500 6 0281 235100 1130 4905 990970 FLOW CUP
54. 0 LJ 21300 0 21310 0 and 21320 0 Size HxWxD 20 x 13x 13cm Weight IN w www stanhope seta co uk Hesidues Particulates Residues amp Composition 12200 3 SETA EXISTENT GUM SOLID BATH ASTM D381 IP 131 IP 540 BS 2000 Part 131 BS 4348 obs ISO 6246 DIN 51 784 NF M07 004 FTM 791 3302 JIS K2261 5 Test stations Integral steam superheater Digital temperature control 140 to 260 C temperature range Flow gauge calibrated for air and steam A Solid Block Bath designed to carry out up to five simultaneous tests for determining existent gum content in fuels by the Jet Evaporation method The unit comprises a solid block bath with integral superheater removable taper fit conical steam air jet adaptor with copper screens and a steam air flow control valve and gauge The bath has five test wells and a thermometer well Outlets can be individually checked for uniform flow of air or steam The bath has a temperature range of 140 to 260 C and is controlled by a digital temperature controller which displays both the set temperature and the actual bath temperature measured by a probe The flow of steam or air is adjusted by an inlet control valve and monitored on a Bourdon gauge calibrated for both air and steam SUPPLIED WITH a Bourdon gauge type flow indicator calibrated for both air and steam five steam air jet assemblies five borosilicate glass beakers and an ins
55. 0 86200 001 86200 002 86300 0 86300 001 86400 2 86000 301 86500 001 86500 2 86500 001 86500 002 86500 003 86500 004 90000 3 90000 301 90000 302 90000 303 90000 304 90000 305 90000 306 90000 307 90000 308 90000 309 90000 310 90000 311 90000 312 90000 313 90000 314 90000 315 90000 316 90000 317 Page Pre Heating amp Filtering Kit 33 35 Disposable Filters pack of 100 Disposable Container pack of 100 Filter 75u with Lid Setatime Six Channel Quartz Timer Display Board Power Supply Board Power Cable Assembly Ribbon Cable amp Connectors Dust Cover Battery Cable amp Clips Counter Board Control Input Socket Assembly KV 8 Viscometer Bath 36 Heatsink amp Triac Assembly Temperature Indicator Assembly Main Circuit Board Assembly 500W Heater Driver Board Probe Assembly Over Temperature Cutout Heater 2000W Heater 500W Fine Temperature Control Potentiometer Stirrer Motor Eprom Sealing Caps KV 6 Viscometer Bath 37 Heater Temperature Probe Fuses pack of 5 Front Panel Elastomer Sealing Caps Foot amp Cover pack of 4 Power Supply Light LED 12V Panel Socket Fan Display PCB Fuse Holder Motor Propeller PSU PCB Power Socket Thermostat Portable Oil Condition Test Kit 96 Insolubles Test Paper Holder pair Insolubles Test Paper pack of 50 9 tests per paper Water in Oil Reagent Pack A amp B 50 tests TBN Reagent Pack C 50 tests Salt Test
56. 0 ADAPTOR for 90012 0 glssware pack of 4 30002 0 e 90011 0 TUBE 100ml cone shaped 6 inch graduated to 0 05ml pack of 6 90003 2 90040 0 TUBE 100ml cone shaped 8 inch graduated to 0 05ml pack of 6 90005 2 90050 0 TUBE 100ml pear shaped 8 inch tip graduated to 0 01ml over the 90041 2 e e e e e e range 0 to 0 2ml pack of 6 90202 2 90060 0 TUBE 100ml trace sediment 8 inch tip graduated to 0 005ml over 90203 2 e e e the range of 0 to 0 01ml pack of 6 190204 2 90012 0 TUBE 12 5ml pack of 6 90200 4 or Note Other items which may be required include Funnel Demulsifier 90300 2 amp e e e e e e Solvents Pipette Stirrer Desiccator 90301 0 Relative Centrifugal Force rcf FAL 90040 0 600 700xg 500 600 700xg 500 800 x g 700 x g 600 x g 700 x g 90010 0 SETAFUGE HAZARD REDUCTION SYSTEM 90050 0 800 x g 90014 0 LOW TROLLEY with lockable castors 68cm high with centrifuge 30060 0 600 700xg 800xg 90015 0 HIGH TROLLEY with lockable castors 99cm high with centrifuge 90011 0 900 x g 90016 0 TRANSFORMER for 110 120V 60Hz operation Sample 49 1 C 90200 4 WATER BATH 15 litre capacity ambient to 100 C for pre heating me 32to35 C 6023 Ct 60 5 ET 32 to 35 C 8221 C 6043 C 25 41 C samples alternative to 90300 2 Test Temp Unheated 60 3 Unheated 60 1 C 4 Unheated 21to32 C 60 1 C 60 3 C Unheated voltage et Se Test Time 10 mins 5
57. 001 All components available separately see table 14090 004 Vi CONFORMANCE CERTIFICATE 44 0 1932 564391 F 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk Composition 14060 0 Columns supplied separately Adsorption Columns and component parts 14070 3 100W 110 120V 50 60Hz 220 240V 50 60Hz 120 x 25 x 15cm 20kg Description Quantity Silicone Rubber Tubing 2 metres Analyser Section Pack of 100 Charger Standard Pack of 2 Ball Joint Pack of 2 Ball Joint Clip Pack of 5 Description Quantity Ball Joint Pack of 2 Tip Pack of 2 Charger Separator Analyser of 2 Ball Joint Clip Pack of 5 Tip Joint Clip Pack of 5 Composition Particulates Residues amp Composition RESTS 21200 0 21200 0 with 24410 4 amp 24500 0 ASPHALTENES APPARATUS ASTM D6560 IP 143 BS 2000 Part 143 DIN 51 595 NF 160 115 Determines the amount of wax free material insoluble in n heptane but soluble in hot toluene Applicable for gas oil diesel fuel fuel oil lubricating oil bitumen and crude petroleum which has been topped to an oil temperature of 260 C Comprises condenser extractor stoppers stirrer funnel and evaporation dish ACCESSORIES Asphaltenes Apparatus REQUIRED RECEIVER 100ml pack of 3 GLASS FLASK 500m capacity FLASK HEATER suitable for one 500ml flask for details see page 31 22160 0 24401 0 24410 4 OR FLA
58. 1 C 76 384 90C Solidification Point 0 to 30 C 0 1 C 76 370 E 134C Sludge 144 to 156 C 0 2 100 270 91C Solidification Point 20 to 50 0 1 76 370 EC Ue 135C Fuel Rating Air High 38 to 93 C 1 40 168 92C Solidification Point 40 to 70 C 0 1 C 76 370 135F Fuel Rating Air High 100 to 200 F 1 F 40 168 93C Solidification Point 60 to 90 C 0 1 C 76 370 E s 136C Aviation Fuel Density 20 to 60 C 0 2 C total 285 94C Solidification Point 80 to 110 C 0 1 C 76 370 REID 136F Aviation Fuel Density 5 to 140 F 0 5 F total 285 95C Solidification Point 100 to 130 C 0 1 C 76 370 SS 137C Oxidation Cell Test 80 to 100 C 0 1 F 76 250 96C Solidification Point 120 to 150 C 0 1 C 76 370 97C Tank 18 to 49 C 0 5 C total 305 97F Tank 0 to 120 F 1 F total 305 98C Tank 16 to 82 0 5 C total 305 a TEMPERATURE CONVERSION FORMULAE 99C Weathering Test 50 to 5 C 020 35 302 5 F E 32 C X 9 32 99 Weathering Test 58 to 41 F 05 35 3 oF 100C Solidification Point 145 to 205 C 02 76 370 ili 9 x 5 i 101C Solidification Point 195 to 305 C 0 5 C 76 370 Temperature amp Fluid Density IP THERMOMETERS ASTM amp IP Thermometers All Seta ASTM IP thermometers are manufactured in accordance with ASTM E 1 and E 77 requirements KEY A Graduations minimum Where numbers appear in both ASTM and IP
59. 12 8 2 11 5 9 46 N10 99771 0 21 17 11 10 74 57 S20 99786 0 4 34 20 18 13 94 35 99832 0 85 65 36 32 22 16 60 99787 0 161 119 60 54 35 24 N100 99833 0 324 234 113 100 62 41 S200 99788 0 649 456 205 181 107 68 D500 99834 0 830 579 224 131 N350 99835 0 1235 851 366 320 184 113 D1000 99836 0 1 696 1159 423 239 S600 99789 0 2 146 1455 598 520 290 173 N1000 99837 0 4 490 2 981 1165 1004 538 309 2000 99790 0 7 946 5 222 1 983 1700 890 499 D5000 99838 0 8 626 5644 1818 945 D7500 99839 0 13 383 8 702 3207 2735 1397 766 N4000 99840 0 17 966 11 627 4216 3589 1811 9981 S8000 99791 0 35 264 22 566 7981 6 748 3327 1760 N15000 99841 0 70 582 44 855 15541 13 087 6 342 3 289 S3000 99792 0 79741 27 285 22 946 10993 5623 LOW TEMPERATURE VISCOSITY STANDARDS DYNAMIC VISCOSITY mPa s cP Standard 40 C 3444 28 89 C 27 C 26 5 C 2611 26 C 255 25 C RefNo PartNo 30 F 20 F 16 6 157 15 F 14 8 F 13 9 F 13 F N27B 99793 0 37449 13281 5313 3 504 N115B 99794 0 142 782 95 380 N480B 99720 0 184000 164400 152500 148400 133600 120400 N1400B 99722 0 JET FUEL JF1 VISCOSITY STANDARD KINEMATIC VISCOSITY mm S cSt Part No 99798 0 23 33 C 10 F 2 360 65 157 80 00 C 176 00 F 1 5 2 5 3 1 3 7 5 7 8 8 13 21 32 38 50 73 122 189 346 589 1 054 1 756 R lt nimis EAR u meis 98 89 C 210 00 F I2 1 9 2 3 2 7 3 9 5 7 7
60. 15x 32x 10cm Weight 3kg ACCESSORIES Dryness Tester 16990 005 SETA ICE BATH comprises an unsilvered dewar flask mounted in a wooden case with viewing windows Note Other items which may be required include Cobalt Bromide plugs Dew Point Apparatus REQU J SETA PRESSURE GAUGES 15600 0 0 to 13 8 bar 0 to 200 psi 16440 0 Oto 8 3 bar 0 to 120 psi 22121 0 Oto 4 bar 0 to 60 psi 22122 0 Oto 40 bar 0 to 600 psi 22123 0 0 70 bar 0 to 1 000 psi 22124 0 Oto 140 bar 0 to 2 000 psi THERMOMETERS 22125 0 0 to 100 F 22126 0 40 to 250 F 22127 0 40 to 460 F 22128 0 TRIPOD with adjustable legs for field use Pre Cooling Apparatus 22160 0 RECEIVER 100ml borosilicate glass for use with the mercury freeze method pack of 3 22170 0 WEATHERING TUBE 100ml graduated centrifuge tube borosilicate glass pack of 3 22180 0 SETA WATER BATH brass for ASTM D1837 THERMOMETERS ASTM99F and 87500 0 Brass Thermometer Case for ASTM D1837 ASTMBF IP1F or ASTM57F for ASTM D2158 ASTMBF IP1F or ASTMSC IP1C for IP 317 e seta co uk W www stan Corrosion CORROSION TESTS 22150 5 22220 4 SETA LPG CORROSION PRESSURE VESSEL ASTM D1838 IP 411 ISO 6251 EN 26251 obs BS 2000 Part 411 BS 6924 NF M41 007 Seamless stainless steel body Pressure tested 70bar 1015psi Used to determine the resistan
61. 2 16160 005 16160 009 16160 202 16160 203 16160 204 16160 207 16160 208 22100 002 Page Fuse pack of 5 Temperature Probe Stirrer Motor Overtemperature Cutout Portable Cambridge Pressure Recorder 67 Recorder Charts psi pack of 100 Ink Capsules Red pack of 5 Pen Arms pair Ink Capsules Green pack of 5 Recorder Charts kPa pack of 100 Neoprene Washer pack of 50 Water Purifier 61 66 68 76 87 102 137 Cartridge Oxi Feed Pressure Vessel 0 Ring Seal pack of 10 Seal 1 8 inch BSP pack of 5 Right Angled Valve Coupling Male Schrader Oxidation Vessel 66 0 Ring Seal pack of 10 Burst Disc Assembly Seal 1 8 inch BSP pack of 5 Right Angled Valve Coupling Male Schrader 66 68 Liner pack of 3 66 Glass Cover for liner pack of 10 Liner pack of 3 Air Release Value Apparatus 104 Grommet pack of 5 Heater Plate Assembly Pressure Gauge Main PCB Assembly Heatsink PCB Triac Assembly Temperature Probe amp Socket Connector Lead Temperature Indicator Circulating Water Bath 104 Fuse pack of 5 Heater Power PCB Temperature Probe Stirrer Motor Display PCB Overtemperature Cutout Density Balance 104 Glass Plummet 10ml Platinum Wire 160mm Balance to Computer Lead Setaclean Total Sediment Tester 86 Filter Paper pack of 100 Buchner Flask Assembly 500ml Sintered Disc pack of 2 Vacuum Gauge Vacuum Hose 5 metres Spherical Joint Stop amp Clip pack of 5 Cylin
62. 2 C total 379 104 85C Solvents Distillation 173 to 227 C 0 2 100 395 68 Precision 293 to 401 F total 379 105C 86C Solvents Distillation 198 to 252 C 0 2 C 100 395 69C Precision 195 to 305 C 0 5 C total 379 106C 87C Solvents Distillation 223 to 277 C 0 2 C 100 395 69F Precision 383 to 581 F total 379 107C 88C Solvents Distillation 248 to 302 C 0 2 100 395 108 Saybolt Viscosity 270 to 290 F 0 5 F total 215 70C Precision 295 to 405 C 0 5 C total 379 109F Saybolt Viscosity 320 to 340 F 0 5 F total 275 70F Precision 563 to 761 F 1 F total 379 71C 72C Oil in Wax 37 to 21 C 76 355 110C 93 Kinematic Viscosity 133 6 to 136 4 C 0 05 C total 305 71F 72F Oilin Wax 35 to 70 F 1 F 76 355 110F Kinematic Viscosity 272 5 to 277 5 F 0 1 F total 305 72C 67C Kinematic Viscosity 19 4 to 16 6 C 0 05 C total 305 111C Tar Acids Distillation 170 to 250 C 0 2 C 100 395 72F 67F Kinematic Viscosity 25 to 25 F 01 F total 305 112 sm Point of to 6 C 0 02 C total 215 73C 68C Kinematic Viscosity 41 4 to 38 6 C 0 05 C total 305 113C 89C Softening Point Wide Range 1 to 175 C 0 5 C total 405 73F 68F Kinematic Viscosity 42 5 to 37 5 F 0 1 F total 305 3 merasa 113F 89 Softening Point Wide Range 30 to 350 F 1 F total 405 74C 69C Kinematic Viscosity 55 4 to 52 6 C 0 05 C total 305 m
63. 200 psi max working pressure 22680 0 HYDROMETER 0 500 to 0 580 g cm3 for ISO and IP Methods Operating temperature range 20 to 45 C 22690 0 HYDROMETER 0 570 to 0 650 g cm3 for ISO and IP Methods 22730 0 THERMOMETER IS0 R653 15 to 45 C for ISO 3993 pressure tested to 22720 0 THERMOMETER BS 593 B60 C Total 20 to 60 C for IP235 22705 0 THERMO HYDROMETER ASTM310H 0 500 0 650 specific gravity Steel safety mesh thermometer 1 1 C to 32 for ASTM D1657 22710 0 THERMO HYDROMETER ASTM101H 0 500 0 650 specific gravity thermometer 30 F to 90 F for ASTM D1657 2 CERTIFICATION UKAS CERTIFICATION OF PRESSURE GAUGES AND HYDROMETERS OPTIONAL For determining the density or specific gravity of light hydrocarbons including LP gases Comprises a polymethylmethacrylate pressure 22101 4 HYDROMETER BATH AND COOLER accepts 22100 0 pressure hydrometer cylinder surrounded by a stainless steel mesh for apparatus as shown maximum safety A vapour vent valve with tee Temperature Range 0 to 100 C piece for a pressure gauge is mounted on the top Voltage 110 120V 50 60Hz A buffer pad is incorporated for the hydrometer and 220 240V 50 60Hz a mounting clip for a thermometer Inlet and outlet Power 1 4kW valves are mounted in the base and the instrumentis Size HxWxD 62 x 35 x 33cm connected to the LPG line via 1 4 BSP connections Weight 30kg Bath 28kg Cooler A range of
64. 250 100 25 0 2 0to3500 010500 250 2 0 to 700 n a 50 n a 0to2000 100 n a 0to3500 n a 250 n a international petroleum L O test methods O CHCI y El correlation and IFIA EI certification schemes Participating in El correlation schemes form a fundamental part of any petroleum laboratory s QA system It is a requirement for laboratories accredited to ISO 17025 to participate in interlaboratory comparison or proficiency testing programmes Being a member of a recognised scheme provides laboratories with a means to demonstrate their ability to meet high level standards to customers on the performance of the laboratory and the integrity of the results generated El Laboratory correlation scheme EILCS The EILCS offers laboratories the opportunity to check their performance on a monthly basis using a variety of commercially available petroleum products forming an important part of any petroleum laboratory s QA procedure Laboratories can test up to 3 of the following products per month e Gasoline e Naphtha e Diesel e Fueloil e Gasoil e Crude oil e Jet fuel Each laboratory receives a monthly and anonymously coded report that enables laboratories to evaluate their performance at a quick glance For further information contact e eilcs energyinst org IP Gasoline and diesel fuel engine correlation scheme CFRCS Laboratories conducting tests for the assessment of automotive fuel quality mus
65. 290 psi 22680 0 HYDROMETER 0 500 to 0 580 g cm3 for ISO and IP Methods 22690 0 HYDROMETER 0 570 to 0 650 g cm3 for ISO and IP Methods 22730 0 THERMOMETER ISO R653 15 to 45 C for ISO 3993 22720 0 THERMOMETER BS 593 B60 C Total 20 to 60 C for IP235 22705 0 THERMO HYDROMETER ASTMS10H 0 500 0 650 specific gravity thermometer 1 1 C to 32 C for ASTM D1657 THERMO HYDROMETER ASTM101H 0 500 0 650 specific gravity thermometer 30 F to 90 F for ASTM D1657 CERTIFICATION UKAS CERTIFICATION OF PRESSURE GAUGES AND HYDROMETERS OPTIONAL HYDROMETER BATH AND COOLER accepts 22100 0 pressure hydrometer apparatus as shown Temperature Range 0 to 100 C Voltage 110 120V 50 60Hz 220 240V 50 60Hz 1 4kW 62 x 35 x 33cm 30kg Bath 28kg Cooler 22710 0 22101 4 Power Size HxWxD Weight OPTIONAL 45000 0 SETAPLUS EXTENDED 12 MONTH WARRANTY ITEMS REQUIRED FOR EACH TEST D1657 obs IP 59 obs IP 235 e e ISO 3993 SPECIFICATIONS CONSUMABLES Pressure Hydrometer App 2 Years 2000 Tests 22100 002 GASKET pack of 10 General Laboratory Equipment Air and Vacuum Pumps AIR AND VACUUM PUMPS 14030 2 14031 0 20290 4 22422 6 80004 0 AIR PUMP Medium capacity Pressure or vacuum delivery For air and non corrosive gases Oil Free Sintered air intake filter SUPPLIED WITH instruction manual AIR PUMP High capacity Pressure or vacuum de
66. 3 brass pin needles 3 stainless steel pin needles Plunger 159 2 cone tipped cylinders 15g and 35g Plunger 47g AOSC 20 aluminium cone 45g Plunger 47 5g weight 80g 40 aluminium cone 31 5g Plunger 15g 3 weights 5g 10g amd 20g tapered perforated disc 19 50 Plunger 47 59 penetration rod 6 3mm diameter 6 4g creams Semi liquid greases creams jams fruit purees mustards ketchup paints varnishes printing inks lacquers 18104 0 Penetrator Kit No 4 ASTM Tapered Hole Disc 18105 0 Penetrator Kit No 5 Pin needle Putty fruit viscous pastes cheese 18101 0 18106 0 Penetrator Kit No 6 Cone tipped cylinder Toothpaste soft pastes printing inks Confectionery edible fats butter margarine solid emulsions Confectionery edible fats butter margarine solid emulsions 18107 0 Penetrator Kit No 7 AOSC Standard Cc 16 60 18108 0 Penetrator Kit No 8 Unilever Mayonnaise mustard semi liquid fats rubber 18109 0 Penetrator Kit No 9 solutions Tapered Hole Disc 18110 0 Penetrator Kit No 10 Penetration rod Silicone rubber PENETRATION CONES ASTM 0217 0937 D1403 IP 50 IP 179 IP 310 BS 2000 Parts 50 amp 179 ISO 2137 DIN 51 580 DIN 51 804 obs NF T60 119 unless otherwise stated 3 17mm 1 8 inch stem diameter SETA PART BODY MASS NOTES 18000 0 18140 0 SETA ASTM IP Standard Cone Acetyl Solid Conical 102 5g 0 05g 18051 0 SETA ASTM
67. 3231 38 103105 36 38 1803170 aa 121 103405 30 VSO 3079 2 8 10 11 15 156 1503680 2 8 10 13 15 156 1503783 31 1503794 u ua 108 1503785 st 86 1503837 Ua 92 56 1503993 116 135 1504256 sss 24 1504257 s 119 123 1504262 s 85 1504263 72 13 VSO 406 sss 80 81 IS05163 101 IS05164 sc 191 1805940 4 sc 54 150 6245 84 VSO 626 DL aaa aaa A 87 1806247 102 103 149 1806251 aaa 76 77 118 1806299 s 56 LL ss UR 0 665 85 VSO 7120 44 aaa 78 0 7536 66 69 SONYA ctt ctt atc 70 1809029 s 31 103030 sU 1509038 16 1809120 ss 104 18010307 sc 86 IS010370 s 84 151 150 11009 10 150 121561190 19012205 sss 72 73 150 13736 18 150 137581 19015267 aaa 2 4 18 ISO CD T1008 5 sss 38 93 150 DIN 3679 5 ss y 13 JIS K2200 sss 55 98 62 JIS K224 sss 116 132 133 135 JISK25S uU 56 JIS K2254 s 28 30 JIS K225 sss 33 JIS K2258 5 22 24 JIS K2261 s 87 JIS K2265 2 4 6 7 18 19 Method Number Method page JIS K2276 sss 52 68 74 JIS K229 sss 32 34 36 38 JIS K2513 rs 68 70 74 JIS K2518 rs 102 103 149 JIS K2580 sc 112 114 0172 2001 78 79 NAS 1638 M 20 DFMO OUT sss 121 NF M07 002 obs 28 29 30 NEMO7 008 s 112 113 NEMO7 013 rss 66 74 NEMO7 015 r 68 74 NF MO7 020 108 93 NE 07 023 ass 94 NF M0702 92 97 NF
68. 44 45 115 IP280 K 10 IP 288 ODS 5 152 31 1 295 n 115 IP 300 Procedure A amp B obs 98 99 IP 303 0bS Ua 2 8 12 13 1 304 ODS 5 aa 2 5 7 IP306 mmm 10 73 IP307 LLL aaa 10 73 IP318 cnn 104 PP BVT omnis 117 IP319 a 36 37 IP 331 obs 0 10 73 IP335 nnn 10 73 IP336 5 5 152 153 150 JP3 150 IP398 5 31 IP399 nnn 108 IP369 5 I LLL aa 143 ICA 55 IP TD o 86 VP J o 58 IP 387 ProceduresA B amp C 5 35 83 1 8 69 72 73 JP 390 Procedure A aaa 86 IP394 vn 22 23 151 IP398 5 c 84 151 IP402 obs UU a 22 24 TP 404 obs 5 2 4 18 IP409 o 22 23 IPOs 24 26 LLL aa 16 77 118 i niin 82 IP 428 nuttin 82 DP 436 oo 91 152 o 150 151 IP AMO CC 82 i MEME 50 51 IP 445 150 Index Method page lo e 150 IP 450 oss 150 151 lio MEME 152 2 7 2 5 7 PE sss 110 lio 80 81 IP PM DJ 2005 68 74 76 77 IP PMDN e 134 IPPMDT 89 IPPMEA 08 ss 10198 28 29 10650 132 133 LS 44 uu 15071922 _ 150 15071516 c 2 1 1501528 25 1 1502049 ss 112 114 150 2083 94 S0217 ua 58 60 62 1502160 sss 68 70 74 102176 25 1502211 aaa 112 150231 aaa A 41 1502718 s 18 1502908 ss 107 1502909 ss 32 34 151 150297 ua 33 1503007 Bo AA 10300 150 1503013 s 32 NOOS _______20 S0 3015 s 30 51 150 10306 50 51 1503104 _____________
69. 5 Heater Stirrer Motor Power PCB Display PCB Temperature Probe Dryness Tester Pressure Gauge 0 4bar Dew Point Apparatus Mirror LPG Corrosion Pressure Vessel Straight Through Valve Nitrile Seal for 1 8 inch BSP pack of 5 Nitrile Seal for 1 4 inch BSP pack of 5 0 Ring Seal pack of 30 Adaptor 1 8 inch BSP 1 4m m pack of 2 Reid Vapour Pressure Bath Heater Power PCB Display PCB Fuse pack of 5 Temperature Probe Stirrer Motor Overtemperature Cutout Corrosion Test Bath Fuse Pack pack of 5 Heater Stirrer Motor Power PCB Display PCB Temperature Probe Main Chamber Valve 0 Ring Seal pack of 30 Valve 20 Ullage Chamber 33 Ullage Chamber 0 Ring Seal pack of 30 Valve Reid Pressure Cylinder Assembly Gasoline Chamber Air Chamber 0 Ring Seal pack of 20 Gasket pack of 100 Reid Pressure Cylinder Assembly Air Chamber 0 Ring Seal pack of 20 Gasket pack of 100 Gasoline Chamber Vacuum Pump Vacuum Hose 2 metres Coupling Filter with gasket Gas Ballast Valve Oil Sight Glass Capacitor pack of 2 Switch Pump Oil 5 litres Pre pressurised Manometer Straight Through Valve Nitrile Seal for 1 4 inch BSP pack of 5 Vacuum Hose 2 metres Valve Page 119 123 119 123 119 123 119 123 119 123 119 123 119 123 119 123 116 135 116 135 117 117 71 118 24 71 118 26 26 26 24 24 136 25 Part Number 22430 202 22430
70. 5000C 600 800 9889 C 10000 505 SFS SFS Ref No PartNo 77 00 100 00 F 104 00 5 12200 F 140 00 F 17600 21000 21200 F 10000 21000 12200 F S3 99784 0 46 4 1 3 1 2 9 24 2 1 15 12 12 05 99830 0 71 6 1 41 33 1 5 S6 99785 0 10 8 8 6 57 45 3 6 25 1 9 1 9 D10 99831 0 15 12 82 77 5 9 46 3 1 23 23 N10 9977 0 21 17 1 10 74 57 37 27 2 6 20 99786 0 44 34 20 18 13 94 57 39 38 97 N35 99832 0 85 65 36 32 22 16 8 8 57 5 6 155 S60 99787 0 161 119 60 54 35 24 13 79 77 280 100 99833 0 324 234 113 100 62 41 21 12 12 522 S200 99788 0 649 456 205 181 107 68 32 18 17 950 90 D500 99834 0 830 579 224 131 38 20 N350 99835 0 1235 851 366 320 184 113 50 2 26 1693 131 D1000 99836 0 1696 1159 423 239 32 S600 99789 0 2146 1455 598 520 290 173 73 38 37 180 137 N1000 99837 0 4490 2981 1165 1004 538 309 122 61 59 2000 99790 0 7946 5222 1983 1700 890 499 189 90 87 D5000 99838 0 8626 5644 1818 945 90 D7500 99839 0 13383 8702 3207 2735 1397 766 122 N4000 99840 0 17966 11 627 4216 3589 1811 9981 346 155 149 8000 99791 0 35264 22 566 7 981 6 748 3 327 1760 589 253 241 N15000 99841 0 70582 44 855 15541 13 087 6342 3289 1054 434 413 3000 99792 0 79 747 27 285 22 946 10993 5623 1756 700 667 DYNAMIC VISCOSITY mPa s cP 40 C 40 F Standard Ref No 27 N115B N480B N1400B Seta Part No 99793 0 99794 0 99720 0 99722 0 37 449 34 44 C 30 F 13 281 28 89 C 20 F 5313 142 782 JET FUEL JF1
71. 5325 NF M07 015 JIS K2513 A range of stirred water or oil filled baths featuring digital temperature control to an accuracy 0 1 C All baths are manufactured from stainless steel and have a stainless steel top plate with multiple positions for test stations Each position is equipped with a lid with an integral hook for suspending either a copper corrosion test vessel Seta 11500 0 or a test tube support Seta 11420 0 A test tube support can hold up to three test tubes Seta 11590 0 Any combination of copper corrosion vessels and test tube supports may be used The Oxi Cor can also accept up to three oxidation test vessels 15550 2 SETA OXI COR BATH Also suitable for OXIDATION TESTS to ASTM D525 D873 D5304 IP 40 IP 138 BS 2000 Parts 40 and 138 ISO 2160 FTM 791 3352 791 3354 NF M07 012 NF M07 013 JIS K2276 and for Accelerated Shelf Life Test for Dried Pet Food Provisional Ambient 5 C to 150 C temperature range 4Atest stations 3 when used for Oxidation Tests Copper Silver Corrosion and Oxidation tests Optional automatic pressure monitoring The Oxi Cor Bath when used with the relevant accessories is an economic and versatile bath capable of carrying out copper silver corrosion tests including ASTM D4814 and oxidation tests including IP 40 Oxi Cor is a four station bath with a maximum temperature of 150 C and is temperature controlled to 0 1 C by a top mounted thermostir circulator
72. 69 74 ASTM 0566 ss 55 ASTM D611 s 33 0613 5 ss 110 ASTM 0665 sss 78 79 ASTMD721 s 107 ASTM 0816 obs s 41 ASTM D850 5 ss 28 23 0873 ss 66 68 69 74 ASTMD87A s 84 ASIMD8 a ua aaa 115 ASTM D892 s 102 103 149 ASTM 0893 s 108 ASTM 0937 s 58 60 ASTM DJ sss 69 ASTM D948 ss 72 73 143 ASTMD97S ss 110 ASTM DIIIS 5 55s 143 01072 97 ASTM 01078 28 30 ASTM 01084 ss 41 01085 55 122 ASTM 011421 ASTMD1200 5 s 4 ASTM 1209 sss 12 ASTM 01264100 ASTMD1265 119 123 ASTMD1268 ss 37 ASTMD1267 s 24 26 ASTMD1290 sss 108 ASTMD1298 sss 32 134 150 151 ASTM DIII ss 1 ASTMD1319 5s 150 151 ASTMDI321 ss 58 01322 20 150 ASTM 1401 108 ASTM 01402 5 55s 69 ASTM DIMI 5 s 58 60 61 ASTM DIM sss A ASTM DISI 5 ss 112 114 ASTM DIM 112 01655 s 32 ASTMDI657 obs ss 116 135 ASTM DT2 uU 106 ASTMDTMA s 150 151 ASTMDT1796 r uU 108 01816115 ASTM DIBI 50 58 63 100 ASTMDI837 ss lA AMD 5 76 77 118 ASTM DIM 5 s 192 ASTM DIJO 5 sss ASTMD2088 5 s 83 U 8 02112 64 65 73 ASTM 02158 11 ASTIMD21 0 JU 30 3 ASTMD2265 s 56 ASTMD2208 u 89899 ASTM D2770 s 32 34 36 37 151 ASTM 02272 64 65 73 2278 ce 108 ASTM 02274 69 72 73 143 ASTM 02276 82 0
73. 86 87 93 104 137 99205 0 DESSICATOR 200ml and Disc 20 82 84 137 99206 0 SILICA GEL 82 99220 2 ASH FURNACE 84 99223 0 PLATINUM DISH 90ml 84 99224 0 ULTRA STIRRER amp STAND 84 86 99300 2 MINI LOW TEMPERATURE BATH CIRCULATOR 10 28 33 35 37 39 102 139 99310 0 EVAPORATION BATH 93 99320 2 ULTRASONIC CLEANING BATH 80 98 142 99600 2 AUTOMATIC OIL TESTER 60kV 115 99605 0 OIL TEST VESSEL 115 99606 0 TRANSPORTATION TROLLEY 115 99610 2 AUTOMATIC OIL TESTER 80kV 115 99620 2 AUTOMATIC OIL TESTER 100kV 115 99620 201 OIL TEST VESSEL 115 99620 202 TEST VESSEL 115 99620 203 OIL TEST VESSEL 115 99625 0 VOLTAGE CALIBRATION METER 115 99700 4 SALT IN CRUDE ANALYSER 94 99708 0 HAND HELD CONDUCTIVITY METER 115 99708 002 BENCH STAND 115 99708 005 CARRY CASE 115 99720 0 LOW TEMPERATURE VISCOSITY STANDARD N480B 48 154 99722 0 LOW TEMPERATURE VISCOSITY STANDARD N1400B 48 154 99771 0 GENERAL PURPOSE VISCOSITY STANDARD N10 48 154 99784 0 GENERAL PURPOSE VISCOSITY STANDARD S3 48 49 154 99785 0 GENERAL PURPOSE VISCOSITY STANDARD S6 48 49 154 99786 0 GENERAL PURPOSE VISCOSITY STANDARD S20 48 49 154 99787 0 GENERAL PURPOSE VISCOSITY STANDARD S60 48 49 154 99788 0 GENERAL PURPOSE VISCOSITY STANDARD S200 48 49 154 99789 0 GENERAL PURPOSE VISCOSITY STANDARD S600 48 49 154 99790 0 GENERAL PURPOSE VISCOSITY STANDARD S2000 48 49 154 99791 0 GENERAL PURPOSE VISCOSITY STANDARD S8000 48 49 154 99792 0 GENERAL PURPOSE VISCOSITY
74. Air Rated Operating Base 10 bar WATER PURIFIER minimises scale formation and connects in line to water supply Maximum inlet pressure 5 bar 75psi and flow 60 hr Comprises fitting kit and filter cartridge ANALYTICAL BALANCE for details see page 141 99200 2 LABORATORY OVEN for details see page 137 45001 0 SETAPLUS EXTENDED 12 MONTH WARRANTY CALIBRATION VERIFICATION amp TRAINING 12250 0 12314 0 15650 0 99100 2 SETA CALIBRATED AIR FLOWMETER for calibrating and verifying the flow Precision flowmeter with negligible back pressure below 1kPa graduated at 510 600 and 690 ml s Size HxWxD 57 14x 17cm Weight 2 3kg CALIBRATION CERTIFICATE WORKS SETA STEAM CALIBRATION KIT connects to the bath jet assemblies and is supplied with a 2 litre graduated cylinder for calibrating and verifying the flow volume of steam 12255 0 Particulates Residues amp Composition Composition An Advanced instrument for the rapid measurement of H S in liquid petroleum products including residual marine fuels and refinery feedstock components aAnalyfics SA4000 0 5 ANALYSER ASTM D7621 IP 570 Determination of Hydrogen Sulfide in Fuel Oil Rapid Liquid Phase Extraction Method ISO 8217 9 Measurement range from 0 250 mg kg H S 0 250 ppm H S in the liquid phase Fast measurement time of 15 minutes Non chemical method no wet chemistry involved Small lab bench footprint fully portable o
75. Apparatus speeds up the determination of lead acid and salt content and permits parallel analysis SUPPLIED WITH instruction manual and mains lead SETAPLUS EXTENDED WARRANTY AVAILABLE ACCESSORIES Dual Extraction Apparatus REQUIRED 14310 0 GLASSWARE 2 twin necked boiling flasks 500ml each comprising a heating tube and coil Hopkins reflux condenser thistle tube Gooch crucible a pair of clips and two 400ml beakers OPTIONAL 99100 2 ANALYTICAL BALANCE for details see page 141 SETAPLUS EXTENDED 12 MONTH WARRANTY 45000 0 SPECIFICATIONS Conductivity range 0 0 to 151 16 1000 Res 0 11b 1000bbl 0 0 to 430 0 g m Res 0 1 g m Power supply 9 volt dc battery or mains adaptor 110 120 220 240 50 60Hz adaptor supplied Weight including carry case 1 6kg CONSUMABLES Salt in Crude Analyser 2 Years 2000 Tests 99700 301 GLASS BEAKER pack of 10 EXTRACTION APPARATUS APPARATUS 14300 3 and Glassware supplied separately SPECIFICATIONS Voltage 110 120V 50 60Hz 220 240V 50 60Hz 86 x 38 x 36cm 104 x 38 x 36cm with _ glassware 15kg Composition Particulates Residues amp Composition TEST KITS 86500 2 SSAFPAK AVIATION FUEL CONDITION TEST KIT Rapid go no go testing Self contained and fully portable Ready to use Six simple to use tests Laboratory quality flash point tester Rugged fitted case A self contained kit of test equipment for rapid
76. C models 0 04 C accuracy 4second response time Hand held secondary reference thermometers with a resolution of 0 01 C and an accuracy of 0 04 C while retaining a response time of less than 4 seconds Measurement is made by a fixed probe on 1m cable Functions include Maximum Minimum and Hold SUPPLIED WITH probe and cable carry case battery and instructions SETATHERM Suitable for D445 verification 20 to 150 C temperature range Precision 0 01 C PT 1000 probe Temperature logging software supplied 2 point calibration certificate Designed for high accuracy applications such as the precise temperature verification of viscometer baths SetaTherm is also suitable for verification of liquid in glass thermometers and digital temperature display devices SetaTherm has a stainless steel PT 1000 immersion probe 150mm long x 3 5mm dia with a 100mm immersion depth and calibrated at 40 and 100 C Accuracy from 20 to 0 C 0 05 C from 0 to 50 C 0 01 C from 50 to 100 C 0 02 C from 100 to 150 C 0 04 C The SetaVisco software allows data to be downloaded onto a personal computer via an RS232 port SUPPLIED WITH probe with 1 2m cable power supply carry case software computer cable and user instructions SPECIFICATIONS Range 20 to 150 C 0 001 C switchable to 0 01 C 0 01 40 C and 100 C 9v power supply or 9V 6F22 PP3 Alkaline Battery 15x8
77. CERTIFICATE WORKS 80008 0 DIGITAL VACUUM GAUGE Press button pressure measurement Temperature compensated sensor ee Battery operated and handheld Operating Temperature 5 50degC Datalogging function Size HxWxD I2x6x 25cm No mercury digital alternative to traditional Weight 20g McLeod gauges The gauge is used in line and has pressure units Mbar Torr and pa SUPPLIED WITH T piece to allow in line connection and a 6 point calibration certificate CALIBRATION CERTIFICATE UKAS h 80008 0 Mass Weight amp Rotation Calibration amp Verification MASS amp WEIGHT 99100 2 ANALYTICAL BALANCE Automatic zero SPECIFICATIONS Selectable units Units of mesurement g mg dwt ct oz Ib GN tl t m Anti vibration filter Weighing capacity 0 to 205gm Glass windshield Readability 0 1mg e RS232 port Reproducibility 0 1mg Response time lt 4 An electronic balance equipped with filters to Mil agi eua _ reduce vibration and a glass enclosure with Free space above pan sliding doors for draught free operation Operating temp 10 to 30 Features include automatic zeroing selectable Size HxWxD 92x 19x 33cm units parts counting p
78. CONTRACT Scheduled maintenance tailored to client needs ad hoc or annual contracts available www stanhope seta co uk 111 Colour Colorimeters COLORIMETERS Colorimetry is the measurement of colour Variations in the colour of a product can indicate differences in its purity composition or deterioration Seta Lovibond colour comparators offer a choice of instruments suitable for all major colour test methods The instruments are simple to use and eliminate the subjective assessment of colour associated with visual comparisons Automatic operation Multiple colour scales including ASTM and Saybolt Rapid measurement lt 25 seconds Objective colour measurement RS232 interface Integrated remote calibration 15260 4 15260 4 MULTICOLOUR AUTOMATIC COLORIMETER ASTM D156 D1209 D1500 D5386 D6045 E308 IP 196 ISO 2049 jg ISO 2211 BS 2000 Part 196 BS 5339 BS 5859 FTM 791 102 DIN 51 411 NF 60 104 NF M07 003 JIS K2580 CALIBRATION amp VERIFICATION MATERIALS An automated spectrometric colorimeter designed for rapid colour analysis of petrochemical products the 15260 4 is selectable for Saybolt ASTM Pt Co Hazen APHA spectral data and CIE colour determinations Parameters are entered via a menu system and subsequent testing is initiated by a single key press with results available within 25 seconds Up to 32 results can be stored in the on board memory The instrument can also be controlled and d
79. Cartridge heater Power 200W maximum 200W maximum 200W maximum 200W maximum Voltage 100 240V 50 60Hz switchable 100 240V 50 60Hz switchable 110 120V or 220 240V 50 60Hz 110 120V or 220 240V 50 60Hz 12Vdc with optional power adaptor 12Vdc with optional power adaptor switchable switchable 12Vdc with optional adaptor 12Vdc with optional adaptor Laboratory gas 3kPa 0 44psi Laboratory gas 3kPa 0 44psi Laboratory gas 3kPa 0 44psi Laboratory gas 3kPa 0 44psi maximum pressure or Butane from maximum pressure or Butane from maximum pressure or Butane from maximum pressure or Butane from optional Portable Gas Tank 13667 0 optional Portable Gas Tank 13667 0 optional Portable Gas Tank 13667 0 optional Portable Gas Tank 13667 0 Size HxWxD 26 x 28 x 26cm 26 x 28 x 26cm 26 x 28 x 26cm 26 x 28 x 26cm wm REN J ACCESSORIES Setaflash Series 3 OPTIONAL 33200 2 33250 2 33000 0 30000 0 138060 BUTANE REFILL CYLINDER ak e 137480 DRAUGHT SCREEN SETAFLASH stainless steel size 19790 SETA SOLID SAMPLE DISPENSER for details see page e 9 l 13770 311 SYRINGE 4ml for tests above 100 C 13870 0 SETA COOLANT MODULE to reduce temperature of cup below ambient down to 0 C REMIT RSEN NIST EXE Uses dry ice and methanol freezing mixture pope or La 26000 0 LIQUID RECOVERY SYSTEM with pump and trap
80. DUAL EXTRACTION APPARATUS 14310 0 GLASSWARE 14420 0 TORPEDO SHAPED DIP WEIGHT 0 7kg 14460 0 TORPEDO SHAPED DIP WEIGHT 1 5kg 14620 0 WATER FINDING RULE 14630 0 WATER FINDING PASTE 100g pack of 10 14640 0 GASOLINE ULLAGE PASTE 100g pack of 10 14700 0 SINGLE WALL SAMPLING CAN 1 litre 14710 0 SINGLE WALL SAMPLING CAN 500ml 14720 0 SINGLE WALL SAMPLING CAN 1 litre 14730 0 SINGLE WALL SAMPLING CAN 500ml 14740 0 DOUBLE WALL SAMPLING CAN 1 litre 14750 0 SINGLE WALL SAMPLING CAN 1 5 litre 14760 2 SAMPLING CAGE 14770 0 SAMPLING BOTTLE 500ml 14790 0 SINGLE WALL SAMPLING CAN 1 litre 14800 0 SINGLE WALL SAMPLING CAN 500ml 14801 0 SINGLE WALL SAMPLING CAN 1 litre 14802 0 SINGLE WALL SAMPLING CAN 2 litre 14810 0 SAMPLING TUBE 14840 0 MULTI LEVEL SELF SEALING SAMPLER 500ml 14841 0 MULTI LEVEL SELF SEALING SAMPLER 500ml 14842 0 MULTI LEVEL SELF SEALING SAMPLER 1 litre 14843 0 MULTI LEVEL SELF SEALING SAMPLER 1 litre 14844 0 MULTI LEVEL SELF SEALING SAMPLER 1 litre 14851 0 MULTI LEVEL SAMPLER 450ml 14852 0 MULTI LEVEL SAMPLER 450ml 14854 0 MULTI LEVEL SAMPLER 500ml 14857 0 MULTI LEVEL SAMPLER 1 litre 14858 0 MULTI LEVEL SAMPLER 1 litre 14859 0 MULTI LEVEL SAMPLER 2 5 litre 14866 2 WINDER 14875 0 UNIVERSAL SAMPLER 500ml 14876 0 UNIVERSAL SAMPLER 500ml 14877 0 UNIVERSAL SAMPLER 1 litre 14940 0 DIP TAPE AND FRAME 15155 2 THERMOSTIR 15200 5 ROBOT BATH 15205 2 AUTOROBOT PRESSURE MONITORING SYSTEM 152
81. Display Integral Barometer amp Auto Correction The Series 8 is an automated closed cup flash point tester with a temperature range of ambient 5 to 300 C ambient 9 to 572 F The instrument uses an electric hot wire ignitor gas flame option There are two modes of operation Flash No Flash and Ramp The ramp mode increases the sample temperature at a rate of 2 C min allowing determination of a flash point in accordance with ASTM D7236 and IP 534 The dipping sequence occurs automatically every 1 C up to 100 C every 2 C rise above 100 C until either a flash is detected or the end of test temperature is reached The ignitor uses a new electrical hotwire a gas flame option is available co N BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS The bright colour LCD display shows test parameters and the test result The text and colour of top line of the display indicates the instrument status All functions are accessed via menus navigated by the keypad Audible prompts are given when an action is required from the operator SETAPLUS EXTENDED WARRANTY AVAILABLE The automatic flash detection system is tuned to ignore halo and other false flash effects reducing the chance of mis interpretation of the test result and enhancing repeatability Barometric pressure is measured by an internal barometer and the correction is automatically applied to the test result At the end of a test the sa
82. IP300 only Solvents 19900 2 ACCESSORIES Cont d REQUIRED Wear ASTM D2266 D4172 19900 2 Only 19940 0 WEAR LOADING KIT for ASTM D2266 and D4172 Comprises a manual lever arm and weight holder Supplied with 8 cast iron weights 3 x 1kg 1 x 500g 4 x 100g OPTIONAL 19750 2 MITUTOYO MICROSCOPE for x y linear measurement Allows direct viewing of ball scar with x30 magnification Voltage 110 120V or 220 240V 50 60Hz switchable SETA RACK to hold 120 used balls prior to wear scar examination ASTM TEST BALLS pack of 500 D2596 D2783 D2266 D4172 SETA TORQUE WRENCH with socket set for 50ft lbf 68Nm Used for tightening the lock nut on the ball holder TRANSFORMER for use with 110V 50 60Hz power supply CHART RECORDER 19900 2 only single channel 0 to 10V input for continuous torque recording 99320 2 SETA ULTRASONIC CLEANING BATH for details see page 142 45002 0 SETAPLUS EXTENDED 12 MONTH WARRANTY CALIBRATION VERIFICATION amp TRAINING 19930 0 LOAD VERIFICATION KIT 19900 2 only 19870 0 19895 0 19890 0 19920 0 19910 0 Tribology Tribology amp Bearing Lubrication h BALL LUBRICANT TESTERS BALL LUBRICANT TESTERS 19800 6 SETA SHELL 4 BALL LUBRICANT TESTER ASTM D2596 D2266 D2783 D4172 IP 239 IP 300 Procedure A amp B obs EN ISO 20623 ISO CD 11008 CEC L 45 T 93 Applied load range 0 to 800kgF Drive speed from 720 to 1900rpm Digital speed control with
83. MEM Size HxWxD 30 x4 x4 cm Weight kg tanh Bearing Lubricant Properties 19400 3 SUPPLIED WITH mains lead and instruction manual ACCESSORIES Roll Stability Tester REQUIRED 19401 0 THERMOMETER AND COLLAR ASSEMBLY 19420 0 CYLINDER mild steel with threaded end cap and smooth finished interiors 19430 0 ROLLER 5kg 500 for use in Seta 19420 0 one required for each cylinder OPTIONAL 99100 2 ANALYTICAL BALANCE for details see page 141 45001 0 SETAPLUS EXTENDED 12 MONTH WARRANTY CALIBRATION VERIFICATION amp TRAINING 99927 0 DIGITAL THERMOMETER WITH INTERCHANGEABLE PROBES for details see page 130 99960 0 DIGITAL PHOTO TACHOMETER for details see page 147 Note Other items which may be required include Solvent 19610 4 ACCESSORIES Water Washout Tester REQUIRED 19620 0 TEST BALL BEARINGS pack of 5 THERMOMETERS ASTM34C IP21C OPTIONAL 99100 2 ANALYTICAL BALANCE for details see page 141 45000 0 SETAPLUS EXTENDED 12 MONTH WARRANTY CALIBRATION VERIFICATION amp TRAINING 22161 0 22750 2 99927 0 RECEIVER 200ml graduated parallel pack of 3 DIGITAL STOPWATCH for details see page 141 DIGITAL THERMOMETER WITH INTERCHANGEABLE PROBES for details see page 130 99960 0 DIGITAL PHOTO TACHOMETER for details see page 147 CONSUMABLES Water Washout Tester 2 Years 2000 Tests 19610 201 DRIVE BELT 19610 206 TUBING CN w
84. Plungers 17510 0 17620 0 or 17790 0 Overflow Ring 17520 0 Grease Cutter 18150 0 17850 0 or 17920 0 17850 0 or 17920 0 Bath Thermometer Roll Stability Tester 18200 5 ASTM17C 63C or 64C 18200 5 18200 5 IP38C 18200 5 ASTM64C Note for ASTM D5 tests Starter Kit 18580 0 contains three 18520 3 Needles ten 18530 0 Containers and one 18550 0 Transfer Dish 18200 5 18200 5 19400 3 Penetration Penetrometer Kits Cones amp Needles PENETRATOR KITS Kits of needles cones containers weights and plungers for specific tests samples Compatible with 0 375 inch 9 53mm plunger diameter penetrometers and SETA 17000 Series SETA PART 18101 0 Penetrator Kit No 1 METHOD ASTM D5 IP 49 DIN 1995 DIN 52 010 EQUIPMENT Plunger 47 59 weight 50g 50 containers transfer dish 3 standard bitumen needles APPLICATIONS Bituminous materials confectionery cosmetics soap yeast chocolate lipstick compact powders Micro cone 5g Plunger 159 u 18102 0 Penetrator Kit No 2 ASTM Micro ds solid or semi solid pharmaceutical cosmetic Micro grease container 3 part creams Micro cone 7g Plunger Lubricants 18103 0 Penetrator Kit No 3 Klein Micro 16 80 Micro grease container solid or semi solid pharmaceutical cosmetic 3 part Plunger 47 59 fat grease sample container ASTM perforated disc penetrator 102 50 Plunger 159 weight 29
85. Point Apparatus REQUIRED 24500 0 SETA STEEL STAND and rod to support 24600 0 24600 0 UNIVERSAL STIRRER for details see page 142 24640 0 STIRRER ROTOR for 24600 0 stainless steel 25000 3 SETA HOT 1000W electric heater variable heat control for details see page 137 REQUIRED 11600 0 only THERMOMETERS 7 5 for the water bath REQUIRED 11610 0 only THERMOMETERS ASTM1C for the water bath REQUIRED 11700 0 only 11750 0 SETA THERMOMETER DEPTH GAUGE THERMOMETERS ASTM2C IP62C or ASTM2F IP62F Note Two thermometers are required CALIBRATION VERIFICATION amp TRAINING 11700 0 only 11760 0 SETA CUP PLUG GAUGE to check dimensions of Grease Cup 11770 0 SETA GO NOT GO CUP GAUGE to check dimensions of Grease Cup orifice OPTIONAL FOR 11600 0 THERMOMETERS 11602 0 5894 THERMOMETER SLEEVE amp CASE 20 to 120 C 11604 0 5894 THERMOMETER SLEEVE amp CASE 100 to 230 C Hardening amp Softening softening Point DROP POINT POINT 11730 2 SETA GREASE DROP POINT OVEN ASTM D2265 ISO 6299 Aluminium solid block oven Six test apertures Temperature range 120 to 345 C e Illuminated chambers The 11730 2 oven is heated by an integral 775W temperature controlled cartridge heater The oven contains six apertures to receive Seta 11740 0 grease cups and support assemblies The chambers are illuminated from the rear to provide a clear view of the sample CALIB
86. Receiving Flask qty 2 Bath Fluid Oil Displ t Ri 2 2 Spirit Level qty 2 a acement Ring qty 2 Cover qty 2 Spirit Level qty 2 Test Positions 2 83253 0 REDWOOD No 1 VISCOSITY KIT IP 70 comprises No 1 Cup Adaptor Viscosity Kits Accepted Redwood No 1 qty 2 Redwood No 1 Viscometer Cup qty 2 Clip qty 2 Kohlrausch Flask Redwood No 2 qty 20 Cup Cover qty 2 Spirit Level qty 2 Saybolt OR _ Bitumen 83255 0 REDWOOD No 2 VISCOSITY KIT IP 70 BS 434 comprises Redwood Voltage 110 120V 50 60Hz Adaptor Key IP 70 Viscometer Cup qty 2 BS 434 Viscometer Cup qty 2 220 240V 50 60Hz Clip qty 2 Kohlrausch Flask qty 20 Cup Cover qty 2 Spirit Level qty 2 OR Power 1 1kW 83257 0 BITUMEN VISCOSITY KIT E102 comprises Cup Adaptor qty 2 Bitumen Size HxWxD 9x 49x 31cm Viscometer Cup qty 2 Universal Orifice Tip qty 2 Withdrawl Tube Wei WE Thermometer Support qty 2 Filter Funnel 60ml Receiving Flask qty 2 gne g Displacement Ring qty 2 Cover qty 2 Spirit Level qty 2 94633 0 BATH OIL 20 litres for filling viscometer baths in the temperature range of ambient to 80 C OR 94635 0 BATH OIL 20 litres for filling viscometer baths in the temperature range of 80 to 120 C OR 94632 0 SILICONE BATH OIL 20 litres for filling viscometer baths in the ALSO AM LAB LE FRO M ETA temperature range of 100 to 150 C THERMOMETERS s nsn Dipu
87. SILICONE BATH OIL 20 litres for filling viscometer baths in the temperature range of 100 to 150 C 3 required VISCOSITY STANDARDS for details see page 48 99928 0 SETATHERM precision logging digital thermometer optimised for verification of viscosity baths for details see page 129 Note Other items which may be required include Solvents for tube cleaning 44 0 1932 564391 1F1 44 0 1932 568363 sales stanhope seta co uk w www stanhope seta co uk 37 Viscosity Kinematic Capillary LOW TEMPERATURE KINEMATIC VISCOMETER BATHS 94710 2 KV 2 LOW TEMPERATURE VISCOMETER BATH ASTM D445 D446 IP 71 BS 188 BS 2000 Part 71 ISO 3104 ISO 3105 DIN 51 561 NF T60 100 791 305 JIS K2283 Temperature range 40 C to 20 C High stability 0 015 20 C 0 01 40 C Accommodates up to 2 standard viscometer tubes Backlighting Insulated viewing window A compact low temperature high stability kinematic viscometer bath with integral refrigeration that can accommodate up to 2 viscometer tubes The refrigeration system gives the stirred bath a temperature range of 20 down to 40 C stable to within 0 015 20 C A twin display shows the current and set temperature Temperature is measured by a PT100 probe The bath has independent over temperature and low fluid level cut outs and a warning alarm The insulated bath is sealed by 8mm thick glass front and rear with 60mm plexiglass p
88. STANDARD S30000 48 49 154 99793 0 LOW TEMPERATURE VISCOSITY STANDARD N27B 48 154 99794 0 LOW TEMPERATURE VISCOSITY STANDARD N115B 48 154 99798 0 JET FUEL JF1 VISCOSITY STANDARD 48 154 99830 0 GENERAL PURPOSE VISCOSITY STANDARD D5 48 154 99831 0 GENERAL PURPOSE VISCOSITY STANDARD D10 48 49 154 99832 0 GENERAL PURPOSE VISCOSITY STANDARD N35 48 49 154 99833 0 GENERAL PURPOSE VISCOSITY STANDARD N100 48 49 154 99834 0 GENERAL PURPOSE VISCOSITY STANDARD D500 48 49 154 Part Number Page 99835 0 GENERAL PURPOSE VISCOSITY STANDARD N350 48 49 154 99836 0 GENERAL PURPOSE VISCOSITY STANDARD D1000 48 154 99837 0 GENERAL PURPOSE VISCOSITY STANDARD N1000 48 49 154 99838 0 GENERAL PURPOSE VISCOSITY STANDARD D5000 48 154 99839 0 GENERAL PURPOSE VISCOSITY STANDARD D7500 48 154 99840 0 GENERAL PURPOSE VISCOSITY STANDARD N4000 48 49 154 99841 0 GENERAL PURPOSE VISCOSITY STANDARD N15000 48 49 154 99850 0 MULTI TEST VERIFICATION MATERIAL Kerosine 5 18 20 28 29 49 53 92 93 150 99851 0 MULTI TEST VERIFICATION MATERIAL Gas Oil 4 18 28 29 49 51 52 150 99852 0 MULTI TEST VERIFICATION MATERIAL Fuel Oil 49 51 151 99853 0 MULTI TEST VERIFICATION MATERIAL Lubricating Oil 4 18 49 51 151 99854 0 MULTI TEST VERIFICATION MATERIAL Motor Gasoline 28 29 49 92 151 99856 0 MULTI TEST VERIFICATION MATERIAL Bitumen 49 54 59 151 99857 0 SINGLE TEST VERIFICATION MATERIAL Kerosine 152 99858 0 SINGLE TEST VERIFIC
89. Seta Auto Duplex Viscometer Tubes are supplied fitted with optical detectors suitable for transparent and opaque samples and are factory calibrated at 40 C in accordance with ASTM D446 calibration at 100 C available on request e SETAVIS SOFTWARE The Windows compatible Setavis KAV software allows simultaneous tube management data logging and analysis of up to 12 Setavis Auto Duplex viscometer tubes A real time display of flow times is provided for left or right hand baths with kinematic viscosity calculated for both upper and lower measuring bulbs The percentage mean difference of upper and lower values is also displayed An integral facility is provided for the automatic calculation of Viscosity Index Results and sample numbers are stored and printed for individual tubes Each tube has a log of calibration constants for both 40 and 100 C values Cleaning cycles are user programmable allowing sample extraction cleaning and drying times to be set for each individual tube H L MEE Setaue s Hoa eee Z 18 cem 7 Eri Tams d iF Toi B ia Demas h E L ipp mtm adr En rj Elm aW am pem mt rri 8 H V argum oe rial iii m sri Kamari Tien inda haj EJ Bi x atii UD LINES s T EP B i s Spa Vis 1m EFT wi Lr LS land i nr i arm SO Darse cm Wu 142 EH
90. Size HxWxD 195 x 59x 60cm 70 x 59 x 50cm Weight 210kg J _ Reference Materials amp Standards DENSITY STANDARDS Density 20 C 0 8720 0 8540 _ 0 8200 Seta Part No 12600 001 STORAGE CABINETS 99970 0 Index Spare Parts Items in italics are consumables Part Number Page Part Number Page Part Number Page 00100 0 Setalert Laboratory Radio Paging System 142 11400 605 Lid for 11400 6 Bath 11870 001 Heat Controller 00100 001 Setalert Transmitter 16155 303 Temperature Probe 13220 002 Brass Test Cup 00100 002 Setalert Receiver 16155 402 Stirrer Motor 13220 003 Lid amp Shutter Assembly 00100 003 Setalert Receiver Charging Unit 16155 406 Overtemperature Cutout 13220 004 Thermometer Collar pack of 10 10000 0 Thin Film Apparatus 93 11430 0 Glassware Silver Corrosion 16 13730 005 Silicone Rubber Tube 4 metres 10000 001 Glass Pump Body 11430 001 Oil Test Tube 350ml 13811 001 Hot Plate 10000 002 Stainless Steel Pump 11430 002 Cold Finger Condenser amp Hook 13230 3 Semi Automatic Tag Open Cup Tester 17 10000 003 Aniline Sample Container 11430 003 Glass Cradle 11870 001 Heat Controller 10000 004 Cover Assembly 11500 0 Copper Corrosion Test Vessel 51 76 13220 004 Thermometer Collar pack of 10 10000 005 Lamp 6 5V pack of 10 11500 001 Ring Seal pack of 30 13230 002 Glass Sample Test Cup 10000 006 Pulley Belt pack of 5 11600 0 Petrolatum Dron Point A t 55 13230 004 Levelling Device 10200 005 S
91. Weight FAME 1 minute or user defined 1 to 99 minutes Typically 7 minutes 80 to 20 C 176 to 68 F in 4 minutes Aluminium Peltier Cell RS232C USB amp LAN options 300W maximum 100 to 250V 50 60Hz 2x AA dry cell batteries required for internal clock 30 x 34 x 38cm kg FAME 1 minute or user defined 1 to 99 minutes Typically 7 minutes 80 to 20 C 176 to 68 F in 4 minutes Corrosion resisting steel insert aluminium cup Peltier Cell RS232C USB amp LAN options 300W maximum 100 to 250V 50 60Hz 2x AA dry cell batteries required for internal clock 30 x 34 x 38cm 8kg FAME 1 minute or user defined 1 to 99 minutes Typically 7 minutes N A Aluminium Ceramic Pad Forced Air post test cooldown RS232C USB amp LAN options 300W maximum 100 to 250V 50 60Hz 2x AA dry cell batteries required for internal clock 30 x 34 x 38cm 8kg Flash Point 5 Point amp Sustained Burning 33200 2 33250 2 Small Scale Flash Point SETAFLASH SMALL SCALE FLASH POINT SETAFLASH SERIES 3 ACTIVE COOL ASTM D3278 D3828 D7236 E502 IP 303 obs IP 523 IP 524 IP 534 ISO DIN 3679 ISO 3680 BS EN 456 BS 3900 Part A13 BS 6664 Part 3 amp 4 UN Class 3 Non viscous Flammable Liquids CHIPS Regulations EPA 1020 A amp B Classification of Dangerous Goods for Carriage Viscous and Non Viscous Liquids Flash No Flash amp Ramp modes 10 to 130 C tempe
92. akana 68 74 RID uuu sassyasaspupwsns cansa apan 32 36 37 I ME 28 30 EN 3678 132 133 Lo 16 7 EN 7538 K 66 69 EN 12595 36 37 ELM A 82 FN TZIO 91 152 153 22 23 151 MEM 90 EN 22719 ua 18 i sees a 50 51 150 EN 61125A B amp C usa 10 EN TSO 1426 191 EN ISO 1427 151 Method page EN IS 2592 2 6 19 ENISO 2719 ua 190 151 EN TSO 3018 smn 150 151 cis MM 150 151 505405 150 151 150 151 EN TSO 4256 s cA uno MM 192 153 EN IS 12937 7 150 DIA T 2 5 150 EN IS 20628 98 99 ECE MM 152 MIN S s C 24 1020 A amp B 2 8 10 11 13 Euro Pharm 2003 Method 111 TestA 55 AL T 113 MILF NU 112 114 XC t 30 51 REC 32 34 36 38 rr 106 FIM FST OOM UU Su 28 29 19 d rcm 56 PTS scott idum 25 FTM 791 3001 obs ss 31 86 7913008 s 82 a Ito 102 AL IL 100 Ni 87 FTM 7813600 asus 33 RULE CET 92 Br co 18 LFU naam 85 ML ILL s 85 au Co M 37 AUUE 68 74 UL 107 7819 02 sacana 1
93. and instruction manual SPECIFICATIONS Disc 1 ASTM No 0 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 Disc 2 ASTM No 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 Wem e ww COLOUR REFERENCE SIANDARDS High stability Certified to UKAS ISO 500ml bottle Suitable for routine calibration of instruments and verification of test results The highly colour stable standards are also suitable for instrument and laboratory correlation Each colour reference standard is packaged in a 500ml bottle and has a shelf life of 12 months 6 months for Pt Co standards CONFORMANCE CERTIFICATE 150 9001 OR CALIBRATION CERTIFICATE UKAS SEE TABLE PLATINUM COBALT COLOUR REFERENCE STANDARDS ASTM D1209 Certified Value nom Certification 5 150 9001 10 ISO 9001 15 ISO 9001 30 ISO 9001 50 ISO 9001 ISO 9001 15250 4 CONFORMANCE CERTIFICATE WORKS ERE SETAPLUS EXTENDED WARRANTY AVAILABLE ACCESSORIES Seta Lovibond Colour Comparator OPTIONAL SETAPLUS EXTENDED 12 MONTH WARRANTY CALIBRATION VERIFICATION amp TRAINING SETA CERTIFIED COLOUR STANDARDS see below for details CONSUMABLES Seta Lovibond Colour Comparator 2 Years 2000 Tests 15250 202 SAMPLE CONTAINER pack of 5 15250 301 HALOGEN LAMP 20W 15250 401 WHITE INSERT REPLACEMENTS pack of 3 45000 0 Certification UKAS to ISO 17025 UKAS to ISO 17025 UKAS to ISO 17025 Seta Part Number 15374 0 15375 0 15376 0 Certi
94. at the end of the test The sample temperature probe is a class A PRT and flash fire detection Is by an ionisation ring Safety features include an initial sweep to check that the sample is below its flash point at the start of the test and a PRT check to ensure that the correct probe is connected and is immersed in sample When in search mode the software limits the maximum temperature to 50 C above expected flash The snuffer automatically deploys at the end of the test or if the independant fire detection probe mounted over the test area detects a flame The hotplate in the 34000 0 is equipped with a cut out to protect against over temperature The optional 34008 0 Cooling Boost Module allows the test area to be rapidly cooled in between tests by a blast of compressed air SUPPLIED WITH DIPS pod Test Area Ignitor Flash Fire Detector sample PRT interconnection leads and instruction manual Note 34000 0 Universal Base Unit required for operation Cleveland Open Cup Tests Flash Point and Fire Point Non Equilibrium Search mode for unknown samples Temperature Range Ambient to 400 C Barometric Correction Automatic Bath N A Heating Hotplate Fan assisted or Forced Air Requires 34008 0 Cooling Boost Module option Post Test Cooling Post Test Cool down Time 90 C to 50 C Ignitor 9 minutes Fan 6 minutes Forced Air
95. business or property and against all actions suits claims and demands charges or expenses in connection therewith for which the customer may become liable in respect of the goods sold under contract in the event that the damage or injury shall have been occasioned otherwise than by the negligence of Stanhope Seta Where Stanhope Seta manufactures goods to the customer s specification or designs goods to the customer s order the customer will indemnify Stanhope Seta against any claims for infringement of any third party rights in respect of such goods or arising from such manufacture 9 Legal construction and arbitration English Law shall apply to all matters in connection with our Terms and with our contract with the customer Any question or dispute arising which cannot be settled between parties shall be determined by the arbitration under the Rules of London Court of Arbitration 10 Copyright Registered trademarks and all intellectual property in any drawings sketches or literature supplied in connection with quotations order or equipment remains the property of Stanhope Seta who reserves the copyright Reproduction of such material may be permitted subject to credits and our prior agreement 11 Risk and title of goods Risk in all goods passes to the customer when the goods leave our factory unless otherwise agreed Title to all goods sold shall remain with Stanhope Seta and shall not pass to the customer until all amou
96. by an internal barometer and the correction is automatically applied to the test result BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS Peltier cell technology is used for heating and cooling ensuring precise temperature control and rapid cooldown after a test is completed The ignitor uses a new electrical hot wire a gas flame option is available The bright colour LCD display shows test parameters and the test result The text and colour of the top line indicates instrument status All functions are accessed via menus navigated by the keypad Up to 64 test results can be stored in memory each tagged with a sample reference SETAPLUS EXTENDED WARRANTY AVAILABLE ENF 82100 0 B BIO d 4 TECHNICAL DATASHEETS AVAILABLE and operator name Results can be downloaded to a PC or printer via e Cup tesperdture SEES the RS232C port USB or LAN ports options available The firmware is Dii tee KM raga SIC te RL Teat duration min Test temporiture OO upgradeable for future developments meis B DOO DAY tama Dr ND HA SUPPLIED WITH Ignitor 2ml syringe mains lead and instruction manual Operator 10 m tor Do STEM Fert n lamio Mire Tait na D00208 lgmtor wir O O OO 62150 0 SETAFLASH SERIES 8 ACTIVECOOL CORROSION RESISTING Corrosion resisting stainless steel cup insert variant of 82100 0 Similar to the 82100 0 with a corrosion resisting insert i
97. columns they are jointly agreed equivalents IP THERMOMETERS IP APPENDIX 1 ASTM APPLICATION TYPE 5C 5F 6C 6F 114C 9C 9F 10C 10F 14C 14F 54C 33C 34C 18C 18F 22C 22 11 11 44 44 45 45 28 28 121 30F 128C 128F 29C 29F 47C 47F 129C 129F Cloud and Pour Cloud and Pour Low Cloud and Pour Low Cloud and Pour Demulsification Demulsification Crude Oil Distillation Low Distillation High Distillation Flushing Case Low Flushing Case Medium Aviation Fuel Freezing Point Low Pensky Martens Low Pensky Martens High Pensky Martens High Pensky Martens Wax Melting Point Wax Melting Point Congealing Point Low Aniline Point Medium Aniline Point Oxidation Reid Vapour Pressure Reid Vapour Pressure Oxidation Stability Oxidation Stability Cleveland Open Flash Cleveland Open Flash Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Sludge Penetration Density Relative Density Drop Point Low Drop Point High Breaking Point FP Cut Back Int RANGE 38 36 80 1 30 4 2 2 0 to to to to
98. comparison of approximate relative viscosity 10ml sample and reference oil size Suitable for clear and opaque liquids Engraved scale A transparent perspex block with three tube and ball testers that allow a simple comparison of a sample to reference oils of higher and lower viscosity The outer tubes are used for reference oils to the highest and lowest permitted viscosity The sample is placed in the centre tube By inverting the Tri Gauge and observing the order in which the balls fall to the bottom of the tubes a simple Go No Go decision can be made The relative viscosities can be determined by reading the position of the sample tube ball against the scale when the first ball reaches the bottom of the tube The scale is graduated with the multiplication factor to be applied to the viscosity of the oil in the tube of the first ball to reach the bottom If the viscosity of that oil is known the viscosities of the sample can be deduced to a reasonable degree of accuracy The reference oils can be left in the Tri Gauge tubes in readiness for future tests SUPPLIED WITH special top closures and instructions for use Size HxWxD 5x5x25cm Weight 0 5kg Comparators Viscosity VISCOSITY COMPARATORS 95000 0 22950 2 Colours shown for demonstration purposes only Viscosity Brookfield BROOKFIELD VISCOMETER BATH VISCOMETER BATH 94830 3 LOW TEMPERATURE BATH ASTM 02983 IP 267 Method A 40to
99. connector 94835 0 n Brookfield Viscosity BROOKFIELD VISCOMETER Viscosity Range 15 to 6 000 000 centipoise Speed 0 01 to 200 rpm Parameters Viscosity Temperature Torque Shear Rate Shear Stress Output Ports Parallel RS232 Serial Analogue Voltage Voltage 220 2404 Size HxWxD 26x 15x 25cm NS Weight 10 5kg CALIBRATION CERTIFICATE WORKS SAMPLE TEMPERATURE C SOFTWARE INCLUDED 30 Air Bath Normal Stator 4 Spindle Liquid Bath Normal Stator 4 Spindle w Liquid Bath SimAir Cell NO e O e A 0 10 20 30 40 50 60 TIME MINUTES Viscosity Saybolt Redwood Bitumen amp Tar SAYBOLT REDWOOD amp BITUMEN VISCOMETER BATH 83201 2 SAYBOLT REDWOOD VISCOMETER BATH ASTM 088 E102 IP 70 obs BS 434 AASHTO T72 791 304 2 cup capacity Saybolt Redwood or Bitumen viscometer kits available Ambient to 250 C 482 F Stability 0 03 C up to 150 C 0 1 C above 150 C 14 litre oil filled bath 1000W heater Cooling coil An oil filled bath designed to heat two sample filled viscometer cups and then maintain them at a constant temperature while the flow time is measured The 14 litre bath has a temper
100. control panel The test cycle includes an audible end of test alarm A 6 place holder for 16ml sample tubes and a 12 place holder for 2ml or 4ml sample tubes are supplied with the instrument for sample tubes see the Accessories box The instrument has an integral condensate trap and an exhaust outlet connection that allows fumes to be vented remotely if testing is not carried out under a fume hood Low pressure and dual over temperature cut outs ensure safe operation Fan assisted air cooling minimises time between tests SUPPLIED WITH 12 place holder 6 place holder removal tool condensate trap oven lid braided hose for N gas 3m rubber exhaust hose bm mains lead and instruction manual 97400 2 Sample Tubes supplied separately ACCESSORIES Micro Carbon Residue Tester Temperature range Ramp rate Thermocouple Pressure controller Primary pressure Flowmeter Flow rate Consumption Power Voltage Size HxWxD Weight Ambient to 500 C 2 10 to 15 C min Iron constanton 20 to 750kPa 1400kPa max 0 1 to 11 Automatic 150ml min or 600ml min Approx 40 I N per test 1 6kW 110 120V 50 60Hz 220 240V 50 60Hz 46 x 35 x 39cm 21kg 97401 0 GLASS SAMPLE TUBE 2ml pack of 100 97402 0 GLASS SAMPLE TUBE 16ml pack of 100 97403 0 GLASS SAMPLE TUBE 4ml pack of 100 for ISO 10370 for use with carbon residues below 0 2 Note Other items which may be
101. detection of contamination in jet aviation fuel Designed for use on the apron and at fuel storage facilities SSAFPAK allows the user to carry out six tests that can quickly provide a go no go decision on aviation fuel quality Flash Point ASTM 03828 A Setaflash Series 3 Closed Cup Flash Point Tester provides either go no go test or can determine the actual flash point of the sample The Setaflash is a laboratory standard instrument featuring an automatic flash detection system that provides a result in two minutes A power inverter is included to allow operation from a 12V dc supply Contamination A Seta Detector Module designed to fit into the cup of the Setaflash Series 3 Closed Cup Flash Point Tester provides an indication of contamination of gasoline by kerosine or kerosine by diesel fuel by comparing residues after evaporation Density A digital meter is provided to measure the density of the sample Conductivity ASTM D2624 A digital meter measures the conductivity of the sample verifying that it remains within specification after the addition of static dissipators Water Content Shell Water Detection Capsules indicate the presence of finely dispersed undissolved water in aviation fuel by a simple colour change providing a rapid go no go result A 5ml sample is drawn through 86500 2 the capsule and the intensity of the colour change gives an indication of the level of contamination with 30ppm water easily dete
102. diameter verification the test selector valve directs air via the porosity air control regulator to the diffuser stone which is immersed in water in a 250ml glass measuring cylinder The digital manometer reads the air pressure required for a bubble to appear at the diffuser stone During permeability verification the test selector valve directs air via the permeability air control valve to the diffuser stone which is ina 250ml Buchner flask the outlet of which is connected to the flowmeter The flowmeter shows the airflow when the digital manometer shows a specified air pressure upstream of the diffuser stone SUPPLIED WITH air pump glassware manometer flowmeter all necessary tubing mains lead and instruction manual ACCESSORIES Verification Kit Foam REQUIRED 22750 2 DIGITAL STOPWATCH hand held 0 1s resolution for details see page 141 CONSUMABLES Verification Kit Foam 2 Years 2000 Tests 14028 202 FLASK 250ml glass 14028 203 CYLINDER 250ml glass 16720 002 SILICONE RUBBER TUBE 5m 14028 4 Mott Diffuser not supplied CALIBRATION CERTIFICATE UKAS MANOMETER amp FLOWMETER SPECIFICATIONS Voltage 110 120V 60Hz 220 230V 50 60Hz DEMULSIFICATION 16500 0 SETA DEMULSIFICATION APPARATUS IP 19 BS 2000 Part 19 DIN 51589 1 NF T60 156 Comprises a glass bodied steam generator emulsifying bath separating bath and oil container SUPPLIED WITH steam piping auxiliary steam
103. flash points in petroleum products by the Cleveland Open Cup method With a nominal value of 258 C this high quality standard should be used to verify system functionality and assure accuracy of laboratory test equipment on a regular basis Manufactured to ASTM D92 IP 36 tested and certified at an accredited laboratory this standard is a time saving welcome addition to any petroleum testing facility Supplied in 80ml bottles Available as packs of 3 99882 0 6 99883 0 or 12 99884 0 bottles CERTIFICATE OF MEASUREMENT WORKS esed TECHNICAL DATASHEETS AVAILABLE DEO Density amp Materials Storage Cabinets DENSITY STANDARDS 99970 0 99975 0 Full compliance to ASTM D1480 Manufactured under ISO 17025 quality standards UKAS Certified Supplied in 100 ml bottles Tamper evident packaging for security and proof of integrity Valid for 2 years CALIBRATION CERTIFICATE UKAS FIRE RESISTANT STORAGE CABINET T90 FIRE RESISTANT STORAGE CABINET T90 CE EN 14470 1 Type 90 RINA Non combustibility Certified Fire Resistant for 90 minutes Automatic hydraulic door closing Rock wool insulation 800 C Certified fire resistant cabinets for sample storage Heavy steel construction with automatically closing doors and rock wool insulation FIRE CERTIFICATE WORKS SPECIFICATIONS Seta Part No 99975 0 Fire Resistance lt 180 C for 90min lt 180 C for 90min internal temp
104. four presets Timer range 0 1s to 9999hr Automatic shut off on seizure Safety splash guard Similar to 19900 2 but with the load applied to the balls via a balance beam and set of calibrated weights As on the 19900 2 the digital speed controller has four programmable presets three are pre programmd to the most commonly used speeds Duration of the test can be controlled by the digital timer which has four ranges and spans 0 1 second to 9999 hours If the balls weld during a test the power to the drive motor is automatically turned off via a torque sensing mechanism SUPPLIED WITH a set of 17 cast iron weights on trolley 6 x 5kg 3 x 2kg 3 x 1kg 1 500g 4 x 100g 1200 test balls DIN 5401 and instruction manual CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE a TECHNICAL DATASHEETS AVAILABLE DOGO 19820 0 Shear Stability Head TEST PARAMETERS ASTM D2596 1770 60 ASTM D2266 1200 50 75 1 7 C ASTM D2783 1760 40 18 to 35 C 60 1 min 10 0 2 secs 10 0 2 secs 6 to 800 6 to 800 40 0 2 Load Wear Index 4 Weld Point Load Wear Index 4 Weld Point Scar diameter Lubricating Grease Lubricating Fluids SPECIFICATIONS Power w O O DIT NL TNNT UT NN Wim KO 19800 6 Lubricating Grease 04172 1 239 L 45 T 93 1475 25 60 1 C 1200 60 75 2 1450 to 1500 10 0 2 secs or
105. glass 14028 203 CYLINDER 250ml glass An apparatus to quickly verify the maximum 16720 002 SILICONE RUBBER TUBE 5m pore diameter and permeability of Mott diffusers and Norton stones used in foam baths Comprising an air pump a test selector valve porosity air control regulator permeability air control regulator glassware digital manometer and a flowmeter all mounted on a chassis with the necessary manifolds and interconnecting tubes SUPPLIED WITH air pump glassware manometer flowmeter all necessary tubing mains lead and instruction manual SPECIFICATIONS _ 110 120V 60Hz 220 230V 50 60Hz SETA CALIBRATED AIR FLOW METER Suitable for Seta Existent Gum Solid Block Baths 12200 0 12200 2 and 12200 3 lt 1 back pressure A precision flow meter for calibrating and verifying the air flow in accordance with the methods of test Graduated and calibrated at 510 600 and 690 ml s SUPPLIED WITH instruction manual SETA STEAM CALIBRATION KIT Suitable for Seta Existent Gum Solid Block Baths 12200 0 12200 2 and 12200 3 Connects to the bath jet assemblies to calibrate verify the flow and volume of steam in accordance with the methods of test SUPPLIED WITH graduated 2 litre measuring cylinder Power 300W Size HxWxD 60 x 45 x 28cm 14028 4 Mott Diffuser not supplied CALIBRATION CERTIFICATE UKAS MANOMETER amp FLOWMETER EXISTENT GUM CALIBRATION EQUIPME
106. have an 18 month validity from date of supply Note The approximate ranges given in the following tables are for guidance only in choosing an appropriate STVM When ordering please quote the Test Name SETA STVM KEROSINE 50ML TECHNICAL DATASHEETS AVAILABLE CERTIFICATE OF MEASUREMENT WORKS FOR THE SPECIFIED TEST METHOD ia No Test Name ASTM Method Range 99857 0 Napthalenes D1840 1 33 to 2 4 vol 99858 0 Sulfur ED X ray D4294 P 336 EN ISO 8754 0 003 to 0 07 m m 99898 0 Aromatics Di HPLC D6379 IP 436 1 44 to 2 82 99898 0 Aromatics Mono HPLC D6379 IP 436 15 2 to 21 2 Yom m 99898 0 Aromatics Total HPLC D6379 IP 436 16 9 to 22 8 SETA STVM GAS OIL 50ML Test Name ASTM Method Range Part No 99859 0 Sulfur ED X ray D4294 P 336 EN ISO 8754 0 003 to 0 016 m m 99867 0 Sulfur WD X ray D2622 0 0009 to 0 013 mm 99869 0 Aromatics HPLC D6591 IP 391 EN 12916 0 6 to 3 6 SETA STVM FUEL OIL 50ML S Test Name ASTM Method Range Part No 99860 0 Vanadium IP 288 obs 16 to 140ug g 99860 0 Nickel IP 288 obs 7 to 45ug g 99862 0 Sulfur ED X ray D4294 IP 336 EN ISO 8754 0 981 to 2 572 m
107. hours in 0 1 second resolution Functions Displays time day month with Audible alarm Hand held digital stopwatch with LCD display in water resistant case SUPPLIED WITH battery and neckcord Size HxWxD 7x6x2cm 22750 2 99965 0 PORTABLE FLOWMETER Oto 200 1 5 accuracy Oxygen or air Tilting display 1 4 inch compression An in line flow meter with an advanced straight Size HxWxD 15x 12 5 x 25cm sensor tube and restrictor flow element to give a high degree of accuracy Pre calibrated for air at an inlet pressure of 5 to 60 psi with a gas temperature between 15 and 20 C SUPPLIED WITH 240V power supply 99965 0 CALIBRATION CERTIFICATE WORKS Instrument Specific Calibration amp Verification FOAM BATH CALIBRATION EQUIPMENT 14028 4 12250 0 12255 0 19930 0 17150 0 VERIFICATION FOAM KIT ASTM 0892 D6082 IP 146 Appendix XI ISO 6247 NF T60 129 JIS K2518 Maximum pore diameter verification Permeability verification Suitable for Mott Diffusers and Norton Stones For use with Seta 14020 5 and 14025 0 Foam Baths ACCESSORIES Verification Foam REQUIRED 22750 2 DIGITAL STOPWATCH hand held 0 1s resolution for details see page 141 CONSUMABLES Verification Foam 2 lt 2000 0 Tests Qty 1 1 1 14028 202 FLASK 250ml
108. ignitor dipping mechanism with a coaxial gas jet electric hot wire ignitor The sample temperature probe is a class A PRT and flash detection is by a thermocouple Safety features include an initial dip to check that the sample is below its flash point a PRT check to ensure that the correct probe is connected and is immersed in the sample and new 10 C dipping protocol When in search mode the software limits the maximum temperature to 50 C above expected flash A bath temperature probe protects against over temperature and an independent fire detection probe is mounted over the teat area The optional 34008 0 Cooling Boost Module allows the test area to be rapidly cooled in between tests by a blast of compressed air SUPPLIED WITH DIPS pod Test Area Ignitor Flash Detector Sample PRT interconnection leads and instruction manual Note 34000 0 Universal Base Unit required for operation s Method Pensky Martens Closed Cup Tests P M Procedures A B amp C GB T 261 PEN Search mode for unknown samples mE Temperature Range Ambient to 400 C Barometric Correction Automatic Bath Solid Block Air Heating I Bottom and side heaters Fan assisted or Forced Air Requires 34008 0 Cooling Boost Module option Post Test Cooling Post Test Cool down Time 36 minutes Fan 6 minutes Forced Air Ignitor Quick fit coaxial gas jet electric hot wire
109. is digitally temperature controlled The hinged hood is fitted with a safety interlock that switches off the motor when opened to protect the operator from the rotating test vessels The bath is equipped with low fluid level and over temperature protection devices Extraction fans remove silicone oil vapours and fumes from the bath The pressure within a test vessel can be automatically measured and displayed in real time using a Seta AutoROBOT Pressure Monitoring System 15205 2 or automatically recorded for downloading post test with a Seta Digi Corder 15230 2 digital recording manometer SUPPLIED WITH mains leads and instruction manual SETAPLUS EXTENDED WARRANTY AVAILABLE Temperature range Ambient to 160 C Temperature stability 01 Bath capacity 12 litres Bath fluid Silicone Oil Number of vessels 2 Rotational speed 100 rev min Voltage 220 240V 50Hz 220 240V 60Hz Power 3 2kW Size HxWxD 113 78 x 88cm Weight 87kg SETA RoBOT OXIDATION VESSEL ASTM 02112 02272 D4742 IP 229 Pressure tested to 5170kPa 750psi Stainless steel construction Low rotational vibration The 15210 5 has been designed to complement the Seta ROBOT Bath An accurately straight stem and a balance arm opposite the valve ensure smooth rotation when the vessel is installed in a Seta ROBOT Bath The oxidation vessel is equipped with a needle valve and a Schrader coupling for charging discharging and i
110. level protection a TREES Temperature Stability 0 1 C Max Circulation Capacity 50 litres A general purpose thermostir which converts most vessels into a thermostatic bath and ks _ features an integral stirrer to maintain Voltage 110 120V 50 60Hz uniform temperature in the bath 220 240V 50 60Hz Temperature is digitally controlled to an Size HxWxD 30 x 10x 17cm accuracy of 0 1 C across a temperature Weight 25kg range of ambient to 99 C The stirrer s paddle is mounted in the centre of the helical heating elementto promote even temperature distribution The mounting clamp accommodates a maximum wall thickness of 20mm The unit is equipped with a low liquid level protection device SUPPLIED WITH mains lead and instruction 15155 2 manual BATH FLUIDS e High flash point Low viscosity e High transparency Seta bath fluids are formulated to maximise the heat stability and efficiency of Seta baths The low viscosity reduces formation and aids dissipation of bubbles 194630 0 40 to 80 BATH OIL 5 litres 94635 0 80 to 120 C BATH OIL 20 litres 194633 0 40 to 80 C BATH OIL 20 litres 94631 0 120 to 150 C SILICONE BATH OIL 2litres 94634 0 80 to 120 C BATH OIL nm 94632 0 120 to 150 C SILICONE BATH OIL 20litres Cooling General Laboratory Equipment 94000 2 99300 2 34006 0 LOW TEMPERATURE BATH CIRCULATOR Temperature range 47
111. litres 33 35 138 94635 0 BATH OIL 20 litres 36 37 46 68 72 76 78 138 94700 2 KV 4 LOW TEMPERATURE VISCOSITY BATH 38 94701 0 VISCOMETER TUBE HOLDER 39 94702 0 VISCOMETER TUBE HOLDER 39 94703 0 VISCOMETER TUBE HOLDER 39 94710 2 KV 2 LOW TEMPERATURE VISCOMETER BATH 38 94800 0 BROOKFIELD LV VISCOMETER 44 45 94830 3 SIMAIR LOW TEMPERATURE BATH 44 94835 0 SIMAIR TEST CELL ASSEMBLY 44 45 95000 0 VISGAGE FOR LIGHT OILS 43 95010 0 VISGAGE FOR HEAVY OILS 43 95020 0 VISGAGE FOR LIGHT OILS 43 95030 0 VISGAGE FOR HEAVY OILS 43 96511 0 GLASS CYLINDER 105 96600 3 HERSCHEL EMULSIFIER 105 96700 0 HERSCHEL EMULSIFIER 105 97005 0 SETA ORBIS DIGISTILL D86 THERMOMETER AND DATA PROCESSOR 29 30 97100 0 VISCOMETER TUBE CLEANER 36 37 39 97300 0 SCHILLING EFFUSIOMETER 116 135 97310 0 TRANSIT CASE 116 135 97320 0 METAL STAND 115 135 97400 2 MICRO CARBON RESIDUE TESTER 84 97401 0 GLASS SAMPLE TUBE 2ml pack of 100 84 97402 0 GLASS SAMPLE TUBE 16ml pack of 100 84 97403 0 GLASS SAMPLE TUBE 4ml pack of 100 84 97410 0 HOLDER 84 97500 0 FREEZE VALVE 117 99000 2 COLD FILTER PLUGGING POINT CFPP APPARATUS 52 99005 0 COLD FILTER PLUGGING POINT CFPP INSERT 52 99100 2 ANALYTICAL BALANCE 21 54 63 64 66 68 72 78 82 84 87 93 94 97 100 106 107 109 141 147 99110 0 CERTIFIED CALIBRATION WEIGHTS set of 11 141 147 99120 0 CERTIFIED CALIBRATION WEIGHTS set of 12 141 147 99200 2 LABORATORY OVEN 20 21 66 68 72 78 82 84
112. m 99866 0 Sulfur WD X ray D2622 0 9709 to 2 578 m m SETA STVM LUBE OIL 50ML Sera Test Name ASTM Method Range Part No 99863 0 Calcium ICP 0 18 to 0 35 m m 99863 0 Zinc ICP 0 09 to 0 15 m m 99863 0 Phosphorus ICP 0 08 to 0 16 m m SETA STVM GASOLINE 5 X 5ML Test Name ASTM Method Range Part No 99865 0 Benzene D3606 EN 12177 0 4 to 0 9 vol 99868 0 Sulfur UVF D5453 IP 490 EN 150 20846 2 2 to 129mg kg STVM Reference Materials amp Standards SINGLE TEST VERIFICATION MATERIALS SETA BIO STVM BIODIESEL 50ML 99905 0 99906 0 ULSD EN590 Biofuel 5 FAME EN 14214 in Diesel A BIO FUEL TESTING Part No Test Name ASTM Method Range 99902 0 Sulfur ED X Ray D4294 P 336 EN ISO 8754 Sample Result 0 003 99903 0 Sulfur WD X Ray D2622 Sample Result 0 0025 99904 0 Aromatics HPLC D6591 IP 391 EN 12916 Sample Result 3 4 Note The approximate ranges given in the table above are for guidance only in choosing an appropriate STVM When ordering please quote the Test Name SETA SIMDIS STVM KEROSINE JET TURBINE FUEL TOML Test Name SIMDIS IBP SIMDIS 10 SIMDIS 50 SIMDIS 90 SIMDIS 95 SIMDIS FBP ASTM Method D2887 IP 406 D2887 IP 406 D2887 IP 406 D2887 IP 406 D2887 IP 406 D2887 IP 406 Range 100 to 180 C 142 to 188 C 183 to 218 C 220 to 249 C 230 to 259 C 244 to 297 C SETA SIMDIS STVM GAS OIL 10ML
113. micro controller Functions include min IAG E memory functions The LCD display Power Supply 4 x AA size batteries not supplied shows speed as RPM m min or ft min Size HxWxD SUPPLIED WITH carry case reflecting tape Weight 2509 and instruction manual 99960 0 CONFORMANCE CERTIFICATE OPTIONAL CALIBRATION CERTIFICATE UKAS Calibration amp Verification amp Flow Wd YYY 83750 3 SIX CHANNEL QUARTZ TIMER Precision timing and verification of SPECIFICATIONS timing devices Six independent channels 0 to 999 99 seconds 0 03 sec between 10 and 60 C Timing A quartz timer with six independent timing channels each with a range of zero to 999 99 seconds Each channel has start stop hold and memory retrieval functions A 9 way D type socket on the rear of the unit allows remote operation of all channels SUPPLIED WITH mains lead and instruction manual Functions Start Stop Display Hold and Memory 100 130V or 200 260V 50 60Hz switchable or 12 15V dc 10 x 20 x 30cm 2 6kg Power Supply Size HxWxD Weight 83750 3 Vi OPTIONAL CALIBRATION CERTIFICATE UKAS 22790 2 DIGITAL STOPWATCH Precision timing large LCD display Alarm SPECIFICATIONS Timing 24
114. not for sale in the EU PRESSURE CERTIFICATE WORKS ACCESSORIES Sampling Cylinders OPTIO Al 21770 0 21790 0 15630 0 21800 0 15630 0 SETA CHARGING LEAD HIGH PRESSURE length 1 metre for pressures up to 46bar 670psi With braided stainless steel outer cover Fitted with Hansen high pressure quick connect couplings male one end female the other 21770 0 SETA RELIEF VALVE HIGH PRESSURE for maximum safety mounted between sample source and the charging lead or the charging lead and sampling cylinder One end fitted with 1 8in BSP female the other 1 8in BSP male Set to relieve at 46bar 670psi 21790 0 SETA QUICK CONNECTION COUPLING HIGH PRESSURE male Hansen to 1 8in BSP male For pressures up to 46bar 670psi 21800 0 SETA QUICK CONNECTION COUPLING HIGH PRESSURE female Hansen to 1 8in BSP male si For pressures up to 46bar 670psi A double valve cylinder with high 21830 0 SETA ADAPTOR 1 8in BSP male to 1 8in BSP male Suitable to convert pressure charging components sampling cylinder valve from female to male Pack of 2 21832 0 SETA ADAPTOR 1 4in BSP male to 1 8in BSP female Suitable for use with 22100 0 Pressure Hydrometer Apparatus Pack of 2 21835 0 SETA ADAPTOR 1 4in BSP female to 1 8in BSP female Suitable for use with 22150 3 LPG Corrosion Test Vessel Pack of 2 21840 0 SETA CONNECTOR PIPE copper 1 4in diameter x 208
115. of 100 Luer to Luer Adaptor pack of 10 Inlet Assembly amp Temperature Sensor Encapsulated Filters 5um pack of 100 Cloud amp Pour Point Cryostat 50 Graduated Jar amp Cork pack of 10 Insulating Gasket pack of 20 Insulating Disk pack of 20 Compartment Thermometer Air Well pack of 4 Cork Jar amp Thermometer Well pack of 10 Temperature Sensor Controller Fuse Heater Fuse Cold Filter Plugging Point CFPP Bath Heater Power Board Display PCB Fuse Probe Stirrer Motor Overtemperature Cutout Compact Cloud amp Pour Point Cryostat 50 Graduated Jar amp Cork pack of 10 Insulating Gasket pack of 20 Insulating Disk pack of 20 Compartment Thermometer Brass Air Well pack of 4 Cork Jar amp Thermometer Well pack of 10 52 139 Part Number 94700 2 94700 201 94710 2 94710 201 94710 202 94710 203 96600 3 96600 301 96600 302 96600 305 96600 308 97005 0 97005 001 97005 002 97005 003 97005 004 97005 005 97300 0 97300 001 97300 002 97300 003 9 300 004 9 300 005 97300 006 97300 007 97400 2 97400 201 97400 202 97400 203 97400 204 97400 205 97500 0 97500 002 97500 003 97500 004 97500 005 97500 006 99000 2 99000 201 99000 202 99000 203 99000 204 99000 205 99000 206 99000 207 99000 208 99000 209 99000 210 99000 211 99000 212 99000 213 99220 2 99200 001 99200 002 99300 2 15155 006 15155 201 15155 204 16155 303 16155 402 1
116. range of Flash Point Testers and is ideal for use where undesirable fumes need to be removed or where protection from air currents is required The unit incorporates fan and controller and can be dismantled for easy storage when not in use SUPPLIED WITH instruction manual and mains lead 2 CALIBRATION amp VERIFICATION MATERIALS X SETAPLUS EXTENDED WARRANTY AVAILABLE Q ACCESSORIES Cleveland SETARAMP CONTROLLER for optional automated temperature control 13815 0 PROBE ASSEMBLY for use with 13663 0 Cleveland 13666 0 BUTANE REFILL CONTAINER pack of 10 13667 0 PORTABLE GAS TANK with on off switch regulator and ignitor Suitable for use with Butane refill 13666 0 containers 71001 0 SETA VENT portable fume extractor and draught excluder excluding flexible ducting 99910 0 PORTABLE DIGITAL BAROMETER 750 to 1150 mbar absolute for details see page 145 45000 0 SETAPLUS EXTENDED 12 MONTH WARRANTY THERMOMETERS ASTM11C IP28C or ASTM 11F IP28F 99880 0 FLASHCHECK pack of 3 for details see page 156 and set points An audible prompt is given at each test temperature interval Note Ramp temperature may be difficult to control during Cleveland tests when testing liquids with a viscosity 800cSt at 25 Ramp rate Variable user definable within the time and temperature limits of the flash point tester automatically controlled Voltage 110 120V 50 60Hz 220 240V
117. relative centrifugal force mode and 99 run profiles can be stored in memory The run duration can be set between 10 seconds and 100 hours in 10 second and one minute increments or set for continuous operation Acceleration and braking time are user adjustable A controlled isothermal band heater holds the temperature between 30 and 80 C and is programmed to compensate for friction heating effects during operation thus ensuring correct sample temperatures throughout the test A brushless asynchronous motor ensures high reliability with low maintenance and the centrifuge has in built error messaging diagnostics SAFETY features include a motor driven lid latch with a safety interlock to prevent centrifuge operation while the lid is unlocked imbalance detection and over temperature protection for both the motor and the chamber The centrifuge is almost silent in operation with measured noise levels below 55 dB A Two types of trolleys are available as optional accessories to allow easy movement of the instrument The centrifuge meets the safety requirements of BS 4402 DIN 58970 IEC 1010 1 IEC 1010 2 D pr EN 61 010 1 amp 61 010 2 BGR 500 Chapter 2 11 Part 3 UVV VBG 4 and VDE 0871 SUPPLIED WITH rotor buckets and cushions Note Bucket adaptors and tubes should be selected from the method table according to test method requirements f BIO FUEL TESTING 90000 3 Auc Oil Test Tubes and Bucket Adaptor
118. required include Nitrogen 97410 0 HOLDER for mixed sample tubes 2 or 4ml x 6 and 16ml x 3 99100 2 ANALYTICAL BALANCE for details see page 141 99220 2 SETA ASH FURNACE ASTM D482 D874 IP 4 IP 163 EN 7 ISO 6245 NF M07 045 NF T60 143 Pre heated airflow system and extended chimney Maximum temperature 1100 C with over temperature cut out and door safety power cut off switch f SUPPLIED WITH laboratory tongs gloves 5 x 100ml and 5 x 120ml tall een form Porcelain Crucibles ACCESSORIES Ash Furnace Capacity 7 litres Chamber size HxWxD 9x 17 x 46cm 99100 2 ANALYTICAL BALANCE for details see page 141 99200 2 LABORATORY OVEN for sample pre conditioning for details see page 137 Power 3 9kW 99205 0 DESSICATOR 200ml and disc Voltage 220 240V 50 60Hz 99223 0 PLATINUM DISH 90ml 99224 0 ULTRA STIRRER AND STAND with dispersing element for sample 65 x 43 x 74cm pre conditioning Weight 63kg Residues Particulates Residues amp Composition CARBON amp ASH RESIDUE SETA CONRADSON TEST UNITS 10610 0 10600 0 10900 3 ASTM D189 IP 13 02416 BS 2000 Part 13 DIN 51 551 ISO 6615 FTM 791 5001 NF T60 116 JIS K2270 SETA CONRADSON TEST UNIT Comprises a cast iron tripod stand Skidmore iron crucible with cover spun sheet iron crucible with cover spun steel circular hood with chimney spun steel circular insulation block and Nichrome wire support
119. temperature range of 80 to 120 C 3 required OR 94632 0 SILICONE BATH OIL 20 litres for filling viscometer baths in the temperature range of 100 to 150 C 3 required 84000 0 Viscometer tubes holders top plate and thermometer supplied separately BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE TECHNICAL DATASHEETS AVAILABLE BLES KV 8 Bath 0 Te CONSUMA OOL 100 SEALING CAPS 8 ACCESSORIES Continued A r7 l a A A If D Ui ITI NIAL 23152 0 VISCOMETER HOLDER 11mm tube size for Ubbelholde amp suspended level viscometers 23154 0 VISCOMETER HOLDER 13mm tube size for Cannon Fenske viscometers 23156 0 VISCOMETER HOLDER 15mm tube size for U tube reverse flow viscometers 83750 3 SETATIME SIX CHANNEL QUARTZ TIMER for time measurement to 999 99 seconds accuracy 99 999 1 digit at 20 for details see page 141 84001 0 DIFFUSED LIGHTING UNIT fits to rear of bath to backlight the tubes 84003 0 COVERS for unused holders lid to minimise heat loss pack of 2 4 packs required 84004 0 CAPS for sealing space around viscometer limbs Can be modified to suit all viscometer tubes 8 required 84005 0 SPIRIT LEVEL 84008 0 BENCH VISCOMETER STAND framework holds viscometer tubes near vertical while being prepared or while draining after use
120. to to to to to to to to to to to to to to to 50 C 120 F 20 C 70 F 105 C 220 F 360 C 300 C 400 C 45 C 85 C 20 C 110 C 230 F 370 C 700 F 82 C 180 F 100 6 C 42 C 105 C 205 C 42 C 108 F 103 C 218 F 400 C 760 F 21 4 C 71 5 F 26 4 C 79 5 F 39 4 C 102 5 F 101 4 C 213 5 F 1 4 C 34 5 F 55 4 C 133 F 61 4 C 142 5 F 94 4 C 202 5 F 156 C 27 C 38 C 100 F 120 C 230 C 30 C 110 C A 1 C 2 F 1 C 2 F 0 5 C 1 F 2 C 1 C 1 C 0 2 C 0 2 C 0 5 C 0 5 C 1 F 2 C 5 F 0 1 C 0 2 F 0 2 C 0 2 C 0 2 C 0 1 C 0 1 C 0 2 F 0 1 C 0 2 F 2 C 0 05 C 0 1 F 0 05 C 0 1 F 0 05 C 0 1 F 0 05 C 0 1 F 0 05 C 0 1 F 0 05 C 0 1 F 0 05 C 0 1 F 0 05 C 0 1 F 0 2 C 0 1 C 0 1 C 0 2 F 1 C 1 C 0 5 C 0 5 C IP 44C 44F 45C 46C 46F 47C 48C 49C 50C 52C 53C 59C 60C 62C 62F 63C 64C 64F 65C 65F 66C 66F 67C 67F 68F 69F B Immersion Depth in C Approximate Total Length in mm ASTM APPLICATION TYPE 35C 15C 16C 2C 2F 61C 12C 12F 43F 46C 46F 72C 72F 73C 73F 74C 74F 126C 126F 71C 71F 3C 37 38 39 40 41C 42C 102C 103C 104C FP Cut Back Int FP Cut Back Ext FP Cut Back Ext Refractometer Gravity Balanc
121. to 2000 rev min SPECIFICATIONS Overload protection Keyless chuck A variable speed stirrer with a range of 100 to 2000rpm The stirrer is designed for use with fluids having viscosities up to 10 000mPas and develops a maximum torque to 15Ncm An overload protection device limits the power to the motor in the event of excessive load on the stirrer The stirrer is equipped with a keyless chuck which can accommodate up to 13mm diameter 220 240V 50 60Hz 23x 8x 24cm ACCESSORIES Universal Stirrer shafts and can be mounted on a standard OPTIONAL 12 7mm retort stand 24500 0 STEEL STAND with mast SUPPLIED WITH retort clamp and instructions 24630 0 FLEXIBLE DRIVE AND PULLEY pack of 2 24640 0 STIRRER ROTOR stainless steel 10200 004 STIRRER ROTOR auger shaped glass rod pack of 5 24600 0 CLEANING BATH 99320 2 SETA ULTRASONIC CLEANING BATH Reduces water consumption SPECIFICATIONS Compact benchtop design Quiet and safe operation Robust and reliable Bath capacity 2 litres Cleaning medium Operating range 20 C to 80 C 0 1 to 99 9 mins Mild alkaline detergent Ultrasonic cleaning is especially suitable for Timing intricate fragile objects such as glassware metal instruments sensors and similar items The bath incorporates high power piezoelectric transducers to
122. to 51 4 83624 0 83624 0Z 100 98 6 to 101 4 83626 0 83626 0Z 150 148 6 to 151 4 83747 2 DIGITAL PIPETTE 50 to 250 for transparent or opaque liquids 83748 2 PIPETTE TIPS disposable pack of 200 94630 0 BATH OIL 5 litres for filling viscometer baths in the temperature range of ambient to 80 C 1 per bath AND OR 94634 0 BATH OIL 5 litres for filling viscometer baths in the temperature range of 80 to 120 C 1 per bath AND OR 94631 0 SILICONE BATH OIL 2 litres for filling viscometer baths in the temperature range of 100 to150 C 3 required per bath 83570 0 SETA BACK FLUSH KIT for cleaning blocked tubes in situ Comprises wash bottle and tubing 83575 2 6 WAY AUTOCLEAN FITTING KIT extends the automatic cleaning function to cover up to 12 tubes 83582 2 SETAVIS SOLVENT CONTAINER 1 required for each solvent type 83578 2 WASTE EXTRACTION SYSTEM two stage diaphragm vacuum pump and 2 waste containers Suitable for cleaning up to 12 tubes mounted in two baths 83700 5 SETA UNIVERSAL PRE HEATING AND FILTERING KIT for use with transparent and opaque samples Comprises hot plate support high temperature 75 micron reusable filter unit and 100 low temperature disposable sample containers with 100 associated 75 micron filters and covers 99300 2 MINI LOW TEMPERATURE BATH CIRCULATOR to provide chilled water if local supply exceeds 18 C for details see page 139 45002 0 SETAPLUS EXTENDED 12 MONTH WARRAN
123. user selectable Electric hot wire pilot light for gas jet Temperature Probes Class A Platinum Resistance Thermometer C or F Thermocouple Flash Detection 105 amp 250 rpm Stirrer Speed Laboratory gas 3kPa 0 44psi maximum pressure Air Supply forced air cooling Dry compressed air 670kPa 100psi maximum pressure Voltage 110 120V or 220 240V 50 60Hz switchable Power 1kW Size HxWxD 40x 45 x 34cm Weight 20kg Multi Method Flash Point 34100 2 mounted on a 34000 0 Base Unit with a 34010 0 Draught Screen fitted BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS SETALERT COMPATIBLE TECHNICAL DATASHEETS AVAILABLE ACCESSORIES Pensky Martens Closed Cup Module SETALERT REMOTE PAGING SYSTEM SPIRIT LEVEL RS232 CABLE for connecting instrument to PC COOLING BOOST MODULE DRAUGHT SCREEN recommended for gas tests PRINTER e 60005 002 DRY WELL PROBE CALIBRATOR for details see page 144 99851 0 99853 0 99908 0 99880 0 99910 0 99960 0 MULTI TEST VERIFICATION MATERIAL 093 IP 34 Gas Oil for details see page 150 MULTI TEST VERIFICATION MATERIAL D93 IP 34 Lubricating Oil for details see page 151 BIO MULTI TEST VERIFICATION MATERIAL Gas Oil for details see page 151 FLASHCHECK secondary verification material for details see page 156
124. vessel 2 CALIBRATION CERTIFICATE WORKS 15620 2 SETA OXYGEN CHARGING LEAD oxygen supply to oxidation vessel 1m long Schrader quick connect couplings one end male one end female 15802 0 SETA OXIDATION VESSEL with mandatory burst disc as required by ASTM D525 D873 IP 40 amp IP 138 for details see page 66 PRESSURE CERTIFICATE UKAS 15803 0 SETA VESSEL CLAMP to hold vessels during opening and closing Can be fixed to a bench 15805 0 SPANNER for oxidation vessel 15810 0 SETA LINER borosilicate glass with cover pack of 3 22750 2 DIGITAL STOPWATCH hand held 0 1s resolution for details see page 141 94633 0 BATH OIL 20 litres for filling bath for temperatures up to 80 C Note 2 required OR 94635 0 BATH OIL 20 litres for filling bath for temperatures between 80 and 120 C Note 2 required OR 94632 0 SILICONE BATH OIL 20 litres for filling bath for temperatures between 100 and 150 C Note 2 required 99100 2 ANALYTICAL BALANCE for tests to D873 for details see page 141 99200 2 LABORATORY OVEN for tests to D873 and IP 138 for details see page 137 AUTOMATIC PRESSURE MONITORING 15450 5 SETA AUTO OXIDATION CONTROL UNIT for details see page 67 OR ENHANCED ANALOGUE PRESSURE MONITORING 15611 2 PORTABLE CAMBRIDGE PRESSURE RECORDER for details see page 67 OR ANALOGUE PRESSURE MONITORING 15600 0 SETA PRESSURE GAUGE for details see page 67 2 CALIBRATION CERTIFICATE WOR
125. with integral over temperature and low fluid level protection devices A Silver Corrosion Conversion Kit Seta 11510 0 is available to convert test stations to hold Seta 11430 0 glassware and a Silver Corrosion Test Kit Gasoline Seta 11515 0 allows silver corrosion tests to ASTM D4814 to be carried out at two test positions For oxidation tests one or more of the lids may be replaced by up to a maximum of three Seta 15802 0 Oxidation Vessels and pressure measuring monitoring devices Further details of using the Oxi Cor as an Oxidation Bath are shown in the Oxidation Section on page 68 15550 2 Corrosion Oxidation glassware and vessels supplied separately SUPPLIED WITH 4 lids mains lead and instruction manual f BIO FUEL TESTING 11400 6 SETA COPPER SILVER CORROSION BATH Ambient 5 to 150 C temperature range Copper and silver corrosion tests 9 stations The 11400 6 is an oil filled bath with a maximum temperature of 150 C and nine test stations The bath is protected against over temperature and low fluid level A Silver Corrosion Conversion Kit 11510 0 is available to provide coolant flow to six sets of silver corrosion glassware 11430 0 SUPPLIED WITH 9 lids mains lead and instruction manual CAE TESTING a TE NE m ta 11400 6 with Accessories supplied separately m pes ae LI y m Corrosion Baths Corrosion amp Rust COPPER amp
126. without Brookfield viscometer or SimAir test cells SimAir is a trademark of Tannas Co This bath when used with SimAir test cells simulates the Air Bath used for tests to ASTM D2983 and IP 267 Method A It is not to be A complete setup for measuring Brookfield Viscosity a 94800 0 Viscometer confused with the Liquid Bath used in IP 267 Method B mounted on a 94830 3 Bath with a 94835 0 SimAir Test Cell SPECIFICATIONS Temperature range Temperature stability Test cell capacity REQUIRED 94800 0 BROOKFIELD LV VISCOMETER 94835 0 TEST CELL ASSEMBLY 1 required for each carousel position in use 94800 0 94835 0 BROOKFIELD LV VISCOMETER ASTM 02983 IP 267 Methods amp B 15 to 6 000 000 centipoise viscosity range 0 01 to 200rpm speed range Built in temperature probe Digital and analogue outputs The 94800 0 is a digital rotary Brookfield LV viscometer suitable for measuring viscosity of ATFs lubricants gear oils and hydraulic fluids in the range of 15 to 6 000 000 centipoise The viscometer features a speed range of 0 01 to 200 rpm in 54 steps and can continuously display viscosity cP or mPa s temperature C or F shear rate shear stress and torque The data can be displayed on the instrument or output via the parallel printer port RS232 serial port or as an analogue voltage for a chart recorder An integral RID probe measures the sample temperature Operati
127. zm 7 lithium battery giving approximately 200 days continous use SUPPLIED WITH RS232 cable instruction manual and software kPa psi bar Note An IBM compatible personal computer not supplied is required SOFTWARE INCLUDED Oxidation Oxidation Stability OXIDATION STABILITY CONSOLE BATH 15400 4 15802 0 SETA OXIDATION STABILITY CONSOLE BATH ASTM D525 D873 IP 40 IP 138 BS 2000 Parts 40 and 138 EN 7536 ISO 7536 NF M07 012 NF M07 013 FTM 791 3352 FTM 791 3354 JIS K2287 Operating temperature 100 C test stations Cold Plunge bath Optional automatic pressure monitoring Integral vessel oxygen charge system Constant water level device Measures the induction period for oxygen in gasoline and allows the weight of gum and residue in aviation fuel to be determined by direct weighing The Seta Oxidation Stability Console Bath comprises a heated water bath with reflux condenser a cold water plunge tank for cooling test vessels after each test and an integral system including oxygen charging lead for charging the oxidation vessels prior to test The bath can accommodate up to four Oxidation Vessels Three methods of pressure measurement are available as accessories ranging from a fully automatic pressure monitoring system to oxygen safe pressure gauges SUPPLIED WITH oxygen charging system mains leads and instruction manual SETAPLUS EXTENDED WARRANTY AVAILABLE
128. 0 VISCOMETER TUBE CLEANER Cleans up to 6 tubes simultaneously Heated solvent vapour process 5to 15 minute cleaning time Low solvent loss A fast and efficient instrument that will clean all current types of viscometer tube internally and externally Up to six viscometer tubes can be suspended in the cleaning chamber Solvent vapours heated to 80 C permeate the viscometer tubes condensing on the internal and external surfaces dissolving any residues from samples passed through the tube during a test A water fed cooling coil at the top of the chamber causes the vapour to continually condense and return to the receiver minimizing solvent loss The use of a low temperature recirculator to chill the cooling water will improve the solvent recovery rate SPECIFICATIONS Voltage 100 130V 60hz 200 240V 50hz 80x 40 x 44cm 23kg ACCESSORIES Viscometer Tube Cleaner OPTIONAL 99300 2 MINI LOW TEMPERATURE BATH CIRCULATOR for details see page 139 Note Other items which may be required include Solvents for tube cleaning 97100 0 Viscometers not included Viscosity Kinematic Capillary GLASS CAPILLARY KINEMATIC VISCOMETER TUBES CAPILLARY KINEMATIC VISCOMETER TUBES 11619 CALIBRATED U TUBE VISCOMETERS U TUBE VISCOMETERS Viscosity Range mm s Nominal Constant Size Code Seta Part BS 188 Type BS U 3to 1 0 001 0 11619 00 0 003 11619 01 With constant and certificate of calibrat
129. 0 C CDFPIFICATIQNG e Integral stirrer Temperature Range Ambient to 120 C Pump for external circulation Display Resolution 01 C Over tem perature protection Temperature Stability 01 Low liquid level protection Powie 12litre bath Voltage _110 120 50 60Hz 220 240V 50 60Hz Stainless steel thermostatic bath with built in Size HxWxD 35 x 35 x 33cm irrer an m nabl irculator stirrer and pump to enable use as a circulato Weight 12 5kg for external apparatus SS The bath temperature is digitally controlled to an accuracy of 0 1 C across a temperature range of ambient to 120 C The circulating pump has a maximum head of 310mbar at zero flow and a maximum flow of 17 litres min 15875 0 C amp P TEST JAR HOLDER holds 10 35mm ACCESSORIES Water Bath 15870 4 at zero head The stirrer paddle is mounted bd in the centre of the helical heating element close to the pump inlet and temperature probe ensuring an even heat distribution The unit is equipped with over temperature and low liquid level protection devices SUPPLIED WITH mains lead and instruction manual 15155 2 THERMOSTIR Temperature range ambient 5 C PECIFIC ATIONS to 100 C w i ti PSPPAT EAS YS i I ES ZEE Temperature Range Ambient 5 C to 100 C Integral stirrer 1 Display Resolution 0 1 C Low liquid
130. 0 Part 69 amp 402 obs EN 12 obs 791 1201 ISO 3007 NF M07 007 JIS K2258 Reid vapour pressure of non viscous petroleum products and volatile crude oil Accurate chamber volume ratio Quick leak free bayonet connection between chambers Chromium plated brass construction SETA REID PRESSURE CYLINDER ASSEMBLY Pressures up to 180kPa 26psi ASTM D323 amp IP 69 Procedures A amp D Hydrostatically pressure tested to 690kPa 100psi SETA REID PRESSURE CYLINDER ASSEMBLY Pressure range 180 to 700kPa 26 to100psi ASTM D323 amp IP 69 Procedure C inch gate valve between gasoline and air chambers A inch needle valve to gasoline chamber Hydrostatically pressure tested to 1380kPa 200psi 22410 0 SPECIFICATIONS ambient 5 C to 90 C 9 F below ambient to 194 F Poen _ ww ACCESSORIES RVP Bath REQUIRED Gasoline amp Volatile Crude Oil PRESSURE CYLINDER Select from RVP CYLINDERS below THERMOMETERS ASTM18C IP23C REQUIRED LPG PRESSURE CYLINDER amp ULLAGE CHAMBER Select from VAPOUR PRESSURE CYLINDERS on page 26 THERMOMETERS ASTM65C OPTIONAL 22210 301 VESSEL SUPPORT BRACKET for extra cylinders stainless steel pack of 2 22510 0 22460 0 22400 0 Typical RVP Cylinder Assemblies Gauge and Manometer Adaptor supplied separately ACCESSORIES Reid Pressure Cylinder Assembly REQUIRED PRESSURE GAUGES Select from SETA RVP GAUGES
131. 000 0 SETAPLUS EXTENDED 12 MONTH WARRANTY 28 litre borosilicate glass No of Baths CALIBRATION VERIFICATION amp TRAINING 14010 4 SETA VOLUME METER for measuring the volume of air at 24 C which has No of Cylinders 4 2 per bath passed through one diffuser stone Tank capacity of 2 5 litres Note One 1000ml borosilicate glass graduated required for each simultaneous test 14028 4 VERIFICATION KIT FOAM for details see page 103 Norton Stone Mott Diffuser verification service available 2 per bath 94 5ml min 14023 0 Mott Diffuser Supply Voltage 110 120V 60Hz CONSUMABLES Dual Twin Foam Baths Fen 2 Years 2000 Tests Size HxWxD 70 x 48 x 40cm 14000 002 GRADUATED CYLINDER pack of 2 Weigh Og 14020 403 DICHROIC LAMP pack of 4 Foaming amp Demulsification Foaming Air Release amp Emulsification FOAM TEST BATHS TEST BATHS 14028 4 VERIFICATION KIT FOAM ASTM D892 Appendix D6082 IP 146 Appendix ISO 6247 NF T60 129 JIS K2518 Verify maximum pore diameter Verify permeability Suitable for Mott Diffusers and Norton Stones An apparatus to quickly verify the maximum pore diameter and permeability of Mott diffusers and Norton stones used in foam baths Comprising an air pump a test selector valve two air control regulators glassware digital manometer and a flowmeter all mounted on a chassis with the necessary manifolds and interconnecting tubes For pore
132. 000 001 80000 024 34000 0 34000 001 34000 002 34000 003 34000 004 34000 005 34000 006 34100 2 34100 001 34100 002 34100 003 34100 004 34100 005 34100 009 34100 010 34100 012 34100 013 34100 014 81002 201 34200 0 34100 002 34100 012 34200 003 34200 004 34200 005 34200 006 34200 007 34700 001 81002 201 34300 0 34100 004 34300 001 34300 002 34300 003 34300 004 34300 005 34300 006 34300 008 34300 009 34300 010 34300 011 34300 012 34301 001 81002 201 34400 0 34100 001 34100 012 34400 002 34400 003 34400 005 34400 006 34400 009 81002 201 34700 0 13740 004 13770 004 34100 012 34200 005 34700 001 34700 002 81002 201 71001 0 71001 001 80000 0 13740 017 17400 007 Page Syringe 2ml Heat Sink Compound Flash Detector Assembly Sample Well Seal Ring Silicone pack of 5 Syringe 4ml Gas Tank Front Panel Assembly Rubber Feet set Service Screw Set Locking Post for Lid Over Temperature Cut Out Wiring Set Controller PCB Closed Cup Sample Block Lid amp Shutter Assembly Fuse 2A pack of 10 Multiflash Base Unit 2 DIPS Control Cable Ignitor Power Cable Electronics Assembly Base Heater Cooling Fan Main Switch Multiflash Pensky Martens Module 4 Flash Detector Sample PRT Test Cup Ignitor Lid amp Shutter Assembly Air Blast Pipe Stirrer Flexible Drive Shaft Hexagonal Key Set Air Bath Heater Dipping Arm Assembly Printer Paper pack of 20 Mult
133. 000 2 this measurement The robust sensor design is ideally suited for on site work as an early warning of possible contamination The test procedure requires no special skills or lab conditions and is therefore suitable for a broad range of applications from batch checking fuels at terminals through to monitoring fuel supplies for standby power generation systems Independent trials show good agreement with laboratory based FTIR methods Compatible Diesel types EN 590 ASTM D975 EsterCheck is easy to operate simply dip the probe into the sample to be measured then press measure and 96 bio diesel will be displayed Detectable Bio Diesel FAME RME SME PME and composite FAMES EN 14214 reading is stored with time and date EsterCheck is housed in a robust ASTM 06751 case with mini USB port that can download readings to a host computer Detectable vegetable oils Sunflower Rapeseed Corn Oil Ground Nut Oil as well as charge the unit Measurement range 1 100 Bio Diesel An additional advantage of the sensor technology is the capability to Omm Ato 70 provide an indication of contamination by non refined vegetable oil petrol or water providing a means to ensure integrity of fuel supplies Working temperature range 5 to 40 C whilst safeguarding plant and storage systems Minimum sample container 30ml The instrument is supplied in a hard case with charger with international IP 6A adaptors sample pots soft
134. 002 Wick 19mm wide pack of 50 11700 002 Test Tube amp Rod pack of 10 S e T 10510 003 Burner Assembly 11730 2 Grease Drop Point 0 56 1555 vamroller prem vven 13663 001 Circuit Board Assembly 10510 004 Oil Container 11700 001 Brass pack of 5 13663 003 Temperature Probe Holder 10600 0 Four Way Conradson Test Unit 85 11730 001 Heater Cartridge 750W 13663 004 Heat Sink Assembly 10600 001 Skidmore Iron Crucible pack of 2 11730 002 Lamp 130V pack of 5 13663 005 Eprom Cd ceo CL lt P S101 sent ichrome Wire Support pack o ermocouple pack o i 10600 004 Spun Steel Hood pack of 2 11740 001 Test Tube amp Rod pack of 10 13811 3 Semi Auto Cleveland Open Cup Tester 19 10600 005 Spun Steel Insulation Block 11870 001 Heat Controller 10600 006 Stand for Four Test Unit 1 hl 23 13230 201 Motor Assembly 11800 005 Top Board 13730 005 Silicone Rubber Tube 4 metres 10610 0 Conradson Test Unit 85 11800 006 Viewing Window 13800 001 Test Cup 10600 001 Skidmore Iron Crucible pack of 2 11850 001 Heater 1000W 13800 003 Thermometer Clip 10600 002 Spun Iron Crucible pack of 2 11869 001 Condenser Cleaning Tool pack of 5 13811 001 Hot Plate 10600 003 Nichrome Wire Support pack of 2 11869 002 Boiling Stones pack of 3 13811 002 Test Flame Applicator EN ui Sr hee ee ul I e 14020 5 Setafoam Dual Twin Foam Test Baths 102 pun Steel Insulation Block 11860 3 Setastill 28 14000 002 Grad d Cvlind kof 1
135. 003 EE pack of 5 16155303 Temperature Probe Emu UMS 18 14090 004 Tip Joint Clip pack of 5 11400 6 Copper Silver Corrosion Bath 74 13000005 Lid amp Shutter Assembly with Stirrer cu a d 11400 601 Heater 13032 301 Thermometer IP74C with collar pack of 2 00 005 Tun pack o D 11400 602 Power PCB 13032 302 Thermometer IP75C with collar pack of 2 11870 001 Heat Dontoller TIU ony 11400 603 Display PCB 13220 2 in Gin Ta T 14300 001 Heat Controller 220 250V only 11400 604 Fuse pack of 5 i sau p ESUS 50000 005 Temperature Indicator Assembly Part Number 14310 0 14310 001 14310 002 14310 003 14310 004 14700 0 14710 0 14720 0 14730 0 14750 0 14700 001 14760 2 14760 001 15155 2 15155 006 15155 201 15155 202 15155 204 15155 205 16155 303 15200 5 14025 005 15200 302 15200 303 15200 305 15200 308 22600 003 22800 001 50000 005 15205 2 15205 001 15205 003 15205 004 15205 201 15205 202 15205 203 15205 050 15450 001 83545 007 15210 5 15210 401 21560 401 15220 0 15220 001 15220 002 15221 0 15221 001 15250 4 15250 202 15250 3501 15250 401 15260 4 15260 3501 15260 303 15260 304 15311 2 15311 202 15311 204 15311 206 15320 2 15260 3501 15260 303 15320 001 15320 003 15320 004 15400 4 15400 001 22600 003 15450 3 15205 001 15450 001 15455 0 15455 002 15455 003 15550 2 11400 601 11400 602 11400 603 Page Extractio
136. 01 1to 11 Long 60 F API Gravity 51HL 12382 01 1to 11 0 to 150 F Gr Thermo 12355 02 9 to 21 Long 60 F Gravity 51HM 12383 01 1to 11 30 to 180 F Gr Thermo 12355 03 19 to 31 Long 60 F Gravity 51HH 12381 01 1 to 11 60 to 220 F Gr Thermo 12355 04 29 to 41 Long 60 F API Gravity 52HL 12382 02 9 to 21 0 to 150 F Gr Thermo 12355 05 39 to 51 Long Q60 F API Gravity 52HM 12383 02 9 to 21 30 to 180 F Gr Thermo 12355 06 49 to 61 Long 60 F Gravity 52HH 12381 02 9 to 21 60 to 220 F Gr Thermo 12355 07 59 to 71 Long 60 F Gravity 53HL 12382 03 19 to 31 0 to 150 F Gr Thermo 12355 08 69 to 81 Long Q60 F Gravity 53HM 12383 03 19 to 31 30 to 180 F Gr Thermo 12355 09 79 to 91 Long 60 F API Gravity 53HH 12381 03 19 to 31 60 to 220 F Gr Thermo 12355 10 89 to 101 Long 60 F Gravity 54HL 12382 04 29 to 41 0 to 150 F Gr Thermo 54HM 12383 04 29 to 41 30 to 180 F Gr Thermo 12356 01 0to6 Short 60 F API Gravity 54HH 12381 04 29 to 41 60 to 220 F Gr Thermo 12356 02 5to 11 Short 60 F API Gravity 55HL 12382 05 39 to 51 0 to 150 F Gr Thermo 12356 03 10 to 16 Short 60 F API Gravity 55HM 12383 05 39 to 51 30 to 180 F Gr Thermo 12356 04 15 to 21 Short 60 F Gravity 55HH 12381 05 39 to 51 60 to 220 F Gr Thermo 12356 05 20 to 26 Short 60 F API Gravity 56HL 12382 06 49 to 61 0 to 150 F Gr Thermo 12356 06 25 to 31 Short 60 F API Gravity 56HM 12383 06 49 to 61 30 to 180 F Gr Thermo 12356 07 30 to 36 Short
137. 02 0 CONSUMABLES Seta Colorimeters 2 Years 2000 Tests Multicolour Automatic 15260 303 OPTICAL GLASS CELL 33mm ASTM D1500 15260 304 OPTICAL GLASS CELL 50mm ASTM D156 15260 301 LAMP 5V 10W lens ended 2 Years 2000 Tests High Precision 15320 001 OPTICAL GLASS CELL 100mm Pt Co Hazen APHA Saybolt 15260 303 OPTICAL GLASS CELL 33mm ASTM D1500 15320 003 OPTICAL GLASS CELL 6 inch IP Units 15320 004 OPTICAL GLASS CELL 10mm Gardner 15260 301 LAMP 5V 10W lens ended 15311 2 SAYBOLT UNIVERSAL CHROMOMETER ASTM D156 DIN 51 411 FTM 791 101 NF M07 003 Two section field of view Three position filter turret A colorimeter with an integral light source for visual determination of the colour of highly refined un dyed liquid petroleum products including gasolines jet fuels napthas and kerosines Comprises of a graduated glass sample column with a clear glass base and a plain glass tube with a three position turret containing colour filter discs An eyepiece provides a split field view of both the column and tube Illumination is from a light source in the base of the unit The height of a column of sample is adjusted until it matches the colour disc in the reference tube The height is then read off the graduations and expressed in Saybolt units SUPPLIED WITH 3 whole colour filter discs and 1 half colour filter disc daylight filter mains lead and instruction manual SPE
138. 028 201 DIGITAL MANOMETER Calibration and cross check of measuring instruments Accurate in situ checks for vacuum and pressure performance Portable handheld instrument for calibration of gauges and apparatus The large LCD screen 0 to100kPa shows readings in kPa or equivalent units of Range measurement can be selected Accuracy 0 25 Full Scale SUPPLIED WITH instrument wallet battery Power Soppi and user instructions pm Size HxWxD 14x7x2 5cm Weight 0 225kg 14028 201 Vi CALIBRATION CERTIFICATE UKAS Calibration amp Verification Pressure amp Vacuum PRESSURE 80005 2 PRESSURE CALIBRATOR 1 SPECIFICATIONS Integral hand pump Weights included An hydraulic dead weight tester with integral hand pump and pressure gauge Includes a set of calibrated weights and adaptors to allow connection to different thread fittings SUPPLIED WITH set of weights CALIBRATION CERTIFICATE UKAS MM ee c cc C L 80007 3 MCLEOD GAUGE A McLeod gauge designed for measuring pressures of true gases in general laboratory SPECIFICATIONS use Range 0 01 to 10 mm A free standing tilting gauge with a constant Size HxWxD 28 x 38 x 33cm zero overflow and a graduated scale Weight 23kg Note Requires mercury charge not included CALIBRATION
139. 0410 0 WICK TRIMMER 10425 0 WICK EXTRACTION APPARATUS 10430 0 INSTRUMENT CASE 10450 0 MIRROR 10500 0 FLAME GAUGE 10510 0 ADLAKE BURNING TEST LAMP 10600 0 FOUR WAY SETA CONRADSON TEST UNIT 10610 0 FOUR WAY SETA CONRADSON TEST UNIT 10710 0 PORCELAIN CRUCIBLE pack of 10 10720 0 BURNER 10730 0 GLASS BEADS 1kg pack 10740 0 BURNER 10750 0 BURNER 10890 0 COKE BULB 10900 3 RAMSBOTTOM CARBON RESIDUE BATH 10910 0 COKE BULB FILLING RACK 10920 0 TONGS 11010 2 CLOUD AND POUR POINT BATH 11200 5 RUST PREVENTION TEST BATH 11210 2 STIRRER WITH AUXILIARY BLADE pack of 2 11220 0 VERTICAL TEST SPECIMEN pack of 5 11220 001 TEST SPECIMEN pack of 5 11225 0 SYNTHETIC SEA WATER SOLUTION 30ml pack of 10 11227 0 SYNTHETIC SEA WATER SOLUTION 300ml 11240 0 ALUMINIUM OXIDE CLOTH 150 grit pack of 50 11241 0 SILICONE CARBIDE PAPER 150 grit pack of 50 11250 0 ALUMINIUM OXIDE CLOTH 240 grit pack of 50 11260 0 BAFFLED BEAKER pack of 4 11275 0 GRINDING AND POLISHING RIG 11280 0 CHUCK BODY AND LOCK NUT 11290 2 PTFE TEST SPECIMEN HOLDER 11300 0 COPPER CORROSION BATH 11305 0 HIGH TEMP COPPER CORROSION BATH 11308 0 COPPER CORROSION BLOCK BATH 11325 0 BEAKER 25ml 11330 0 PAIR OF TEST SPECIMENS 11335 0 BEAKER COVER AND TEST SPECIMEN HOLDER 11400 6 COPPER SILVER CORROSION BATH 11420 0 SUPPORT pack of 2 11430 0 SILVER CORROSION GLASSWARE 11440 0 SILVER TEST STRIPS pack of 5 11450 0 ASTM COLOUR STANDARD 11460 0 SILICON
140. 06 IP 307 IP 331 obs IP 335 EN 61125A B and C IEC 61125 Methods A B and C BS 2000 Parts 48 280 and 306 ISO 2160 ISO 7624 DIN 51 811 NF T60 150 JIS K2513 Suitable for heating samples for Copper Strip Tests to ASTM D4048 IP 112 BS 2000 Part 112 Solid Block Bath alternative to ASTM D130 and IP 154 SETA HIGHTEMP BATH UNIVERSAL OXIDATION Solid block bath 50t0375 C temperature range 15 wells in three sizes Up to 6 simultaneous tests A solid block bath for oxidation and thermal stability tests that allows up to six tests to be carried out simultaneously Comprises a solid block bath flow control unit flowmeters supplied separately and a digital temperatue controller The aluminium solid block bath maintains a set temperature to within 0 5 C across a range of 50 to 375 C The top of the bath is insulated by a ceramic pad and the vacant test wells have removeable ceramic covers The bath can accept six 27mm oxidation cells or six 39mm oxidation cells or three 51mm oxidation cells The flow control unit comprises a gas inlet pressure regulator pressure gauge and mounts for six flowmeters The digital temperature controller is simple to operate and features an easy to read high visibility blue display SUPPLIED WITH flow control unit digital temperature controller mains leads and instruction manual Note Flowmeters glassware and catalysts must be ordered separately BIO FUEL TES
141. 0610 001 Tripod Stand pack of 2 raduated Cylinder pack of 2 11860 006 Viewing Window 14000 003 Test Bath Borosilicate Glass 11010 2 Cloud amp Pour Point Bath 51 11860 204 Heater 1000W 14020 403 Dichroic Lamp pack of 4 11000 001 Metal Jacket pack of 2 11860 207 Energy Regulator 14020 505 Clamp Ring 11000 002 Graduated Jar with cork pack of 10 11869 001 Condenser Cleaning Tool pack of 5 14020 406 Flowmeter 11000 003 Insulating Gasket pack of 20 11869 002 Boiling Stones pack of 3 15155 006 Fuse pack of 5 11000 004 Insulating Disc pack of 20 11870 001 Heat Controller 15155 201 Heater 11200 5 Rust Prevention Test Bath 78 17400 007 Mains Lead 15155 202 Stirrer Motor 11200 005 Beaker 400ml pack of 10 11900 0 Asphalt Distillation Unit 31 15155 205 Display PCB 11200 501 Drive Belts pack of 6 11900 001 Shield 15166 206 Fuse pack of 5 11200 502 Motor 11900 002 Chimney 16155 303 Temperature Probe 11200 503 Stirrer pack of 2 11900 003 Cover 14028 4 Verification Kit Foam 103 149 11225 0 Synthethic Sea Water Solution 11900 004 Chimney Support 14028 201 Digital Manometer 11227 0 Synthethic Sea Water Solution 11900 005 Nichrome Wire Support pack of 2 14028 202 Flask 250ml Glass 15155 006 Fuse pack of 5 11910 0 Glassware 31 14028 203 Cylinder 250ml Glass E one 11910 001 Distillation Flask pack of 2 16720 002 Silicone Rubber Tube 5 metres i renter Probe anaes oe pack ot 14030 2 Air Pump 136 aptor Spout pack of 2 140
142. 1 93531 7 11000 002 11000 003 11000 004 93531 001 93531 201 95531 202 93531 315 93531 601 93531 602 94000 2 11400 601 11400 602 11400 603 11400 604 16155 303 16155 402 16155 406 94100 3 11100 002 11000 003 11000 004 93531 001 93531 201 93531 202 Page Lid Lock Temperature Sensor Rotary Knob Terminal Circuit Breaker 120V main switch Speed Imbalance Sensor Motor for Lid Lock 120 230V Micro Switch for Lid Lock Heater Element Power Cable 230V Handle Motor Rubber Mounts Hinge stainless silver Sight Glass Inner Part Chamber Gasket grey Motor Cover Lid Lock left hand without motor Rubber Foot Motor Cover Flange Imbalance Switch Holder Sight Glass outer parts Water Bath 109 Fuse pack of 5 Heater Stirrer Motor Power PCB Display PCB Temperature Probe Multi Filtration Tester 83 Printer Paper pack of 20 Precision Pump Reservoir Beaker Pressure Sensor Control PCB Display Assembly Fuse 1 Amp pack of 10 Restrictor with 0 Ring Damper Extraction Key Tubing 1 metre Forceps IP 387 D2068 0 Ring Seal Kit Adaptor Luer Pump Relay Pump Power Supply Pump PCB Assembly M5 Spigot Connector for inlet outlet pipes Port Block only Pressure Switch Damper with 0 Ring Cover Mk3 Outlet Swivel Assembly Inlet Assembly with PT100 Port Block Filters 1 6um pack of 100 Gasket flat teflon pack of 10 13mm Filter Holder Encapsulated Filters 1 6um pack
143. 10 5 ROBOT OXIDATION VESSEL 15211 3 SPANNER AND BENCH PLATE 15215 0 VESSEL STEM GAUGE 15220 0 GLASS LINER AND PTFE COVER 15221 0 ACCESSORY KIT 15230 2 DIGI CORDER 15240 0 KEY 15250 4 SETA LOVIBOND COLOUR COMPARATOR 15260 4 MULTICOLOUR AUTOMATIC COLORIMETER 15262 0 GARDNER COLOUR SCALE 15301 0 ASTM COLOUR CONFORMANCE FILTERS set of 3 15302 0 SAYBOLT COLOUR CONFORMANCE FILTERS set of 5 15311 2 SAYBOLT UNIVERSAL CHROMOMETER 15320 2 SETA LOVIBOND HIGH PRECISION COLORIMETER 15370 0 ASTM COLOUR REFERENCE STANDARD 15371 0 ASTM COLOUR REFERENCE STANDARD 15372 0 ASTM COLOUR REFERENCE STANDARD 15373 0 ASTM COLOUR REFERENCE STANDARD 15374 0 GARDNER COLOUR REFERENCE STANDARD 15375 0 GARDNER COLOUR REFERENCE STANDARD Page 14 14 97 102 102 102 102 102 102 102 102 102 145 102 103 149 102 52 86 107 136 136 92 92 92 92 92 92 92 92 102 102 94 94 122 122 122 122 122 121 121 121 121 121 121 122 122 121 121 121 121 122 120 120 120 120 120 120 120 120 120 120 120 120 121 120 120 120 122 113 113 114 113 114 113 112 114 155 114 155 114 155 114 155 114 155 114 155 Index Product Number Part Number Page 15376 0 GARDNER COLOUR REFERENCE STANDARD 114 155 15380 0 PLATINUM COBALT COLOUR REFERENCE STANDARD 114 155 15381 0 PLATINUM COBALT COLOUR REFERENCE STANDARD 114 155 15382 0 PLATINUM COBALT COLOUR REFERENCE STANDARD 114 155 15383 0 PLATINUM COBALT COLOUR REFERENCE
144. 1300 0 or 11305 0 2 required for 15550 0 or 11400 6 COPPER amp SILVER TEST STRIPS 22190 0 COPPER TEST STRIP ASTM D1838 IP 411 BS 2000 Part 411 BS 6924 EN 6251 ISO 6251 NF M41 007 99 9 purity Finished to 75 x 12 5 x 2 4mm with 3 0mm hole for suspension Ready for final polish according to the test method Supplied in pack of 30 strips SILVER TEST STRIP ASTM D4814 IP 227 obs IP PM DJ 2005 99 9 purity 11440 0 Finished to 19 x 12 7 x 3mm Ready for final polish according to the test method Supplied in pack of 5 strips COPPER TEST STRIP ASTM D4048 IP 112 BS 2000 Part 112 99 9 purity 11550 0 Finished to 75 x 12 5 x 2 4mm Ready for final polish according to the test method Supplied in pack of 30 strips CONFORMANCE CERTIFICATE WORKS ACCESSORIES Cont d REQUIRED 94635 0 BATH OIL 20 litres for filling bath for temperatures between 80 and 120 C Note 1 required for 11300 0 or 11305 0 2 required for 15550 0 or 11400 6 THERMOMETERS ASTM12C IP64C or ASTM12F IP64F OPTIONAL 15650 0 WATER PURIFIER to minimise scale production Note Other items which may be required include Solvents Stainless steel forceps ITEMS REQUIRED FOR EACH TEST Copper Corrosion Silver Corrosion D130 D4048 D4814 IP 154 IP 112 IP PM DJ 2005 IP 227 e Items marked IB are available as a kit Seta Part No 11515 0 for tests to ASTM D4814 Item marked A is only suitable for u
145. 15 RE T 122 FTM 791 Method 3000 ss 108 III 3005 Ll oemicievicia 108 FTM 791 Method 3004 sss 108 oo 81 2 4 81 GJB 420 1996 ss 81 GJB 420B 2006 s 81 81 les A M V Health amp Safety Commission carriage of dangerous goods by road and rail Appendix B s i Appendix Dat IATA Dangerous Goods Regulations xr m Section 342 el IEC 61125 Methods A B amp G U 70 73 I nnn 93 BE 84 BOO UU 21 li ee E 85 la 85 50 51 150 151 PI UU 52 150 VVU 31 l MEME 55 ME SO NOUS PCR 18 BA UU 2 4 18 150 151 Dr ENEAS 2 6 19 x MTM 66 68 69 74 pda teste 10 p NUS 38 60 151 MEE 58 60 62 lio 119 121 123 gc PIPER 86 IP 55 56 Method page IPSI 20 150 54 151 IP 59 Method C obs 116 135 22 25 IP ssa oes estat 2 5 46 32 34 36 38 150 151 IP75 obs 5 aa 108 104 obs 5 0 119 123 IPT C 68 74 76 j s E 106 28 30 150 151 IP138 a ua 66 68 69 74 1 Cos 143 IP AG o 102 103 149 VP 156 JJ 92 150 151 IP158 107 IP160 ua 132 134 150 151 58 60 181 obs 0 119 123 IP189 conn 143 IP190 UJU aa 143 IP196 55 112 114 IP215 mnt 100 1 9 50 51 150 151 IP226 5 5 32 34 36 37 151 IP285 IU 116 135 239 98 99 IPB 55 94 IP265 5 94 IP267 5
146. 150 649 M50SP SERIES 60 60 F RELATIVE DENSITY BS 718 150 649 L50SP SERIES 60 60 F ASTM 01298 IP 160 API 2547 BS 4714 obs DIN 51 757 EN 3675 ISO 650 NF T60 101 JIS K2249 RELATIVE DENSITY HYDROMETER SELECTION CHART E100 Long E 100 Short 50 150 ASTM Ref Seta Part ASTM Ref Seta Part Seta Part Seta Part 81H 12351 01 12320 01 12321 01 82H 12351 02 102H 12320 02 12321 02 83H 12351 03 103H 12320 03 12321 03 84H 12351 04 104H 12320 04 12321 04 85H 12351 05 105H 12320 05 12321 05 86H 12351 06 106H 12320 06 12321 06 87H 12351 07 107H 12320 07 12321 07 88H 12351 08 108H 12320 08 12321 08 89H 12351 09 12320 09 12321 09 1 050 to 1 100 90H 12351 10 12320 10 12321 10 12352 01 12352 02 12352 03 12352 04 12352 05 12352 06 12352 07 DENSITY HYDROMETERS BS 718150 649 12430 12431 12460 12461 E 12384 0 DENSITY BS 718150 649 505 SERIES 15 C DENSITY BS 718 150 649 L50SP SERIES 15 C SPECIFICATIONS Seta Series BS ISO Series Reference 12320 12321 12351 12352 M50SP L50SP E100 Long E100 Short 60 60 F 60 60 60 60 F 60 60 F CNN e 7 NN 000156 0 000588 0000556 0 00156 0 0006 56 0 000356 0 0005SG 000156 Yr CONFORMANCE OR CALIBRATION CERTIFICATES WORKS OR UKAS AVAILABLE SEE PAGE 131 FOR DETAILS Temperature Scale Sub Division ASTM D1298 IP 160 API 2547 BS 4714 obs DIN 51 757 EN 3675 ISO 650 NF T60 101 DENSITY BS 718150 649
147. 170 0 ASTM 036 IP 58 EN 1427 BS 76 im BS 2000 Part 58 BS 6043 Part 1 ISO 5940 NF 66 008 obs STPTC Pt 3 a Four ring holder j Circular base plate 14 i 25000 3 21003 2 RING AND BALL TEST UNIT ASTM E28 IP 58 EN 1427 ring holder Spectacle shaped base plate HI ACCESSORIES 21000 Series Ring amp Ball Test Units Typical Softening Point setup REQUIRED Refer to the table of ITEMS REQUIRED FOR EACH TEST and select from the following options ITEMS REQUIRED FOR EACH TEST S S S s S E E EEEKk E 21170 0 BEAKER 800ml borosilicate glass for two and four test units Seta No E28 D36 58 EN1427 5 76 STPTC 24500 0 SETA STEEL STAND and rod to support 24600 0 24600 0 UNIVERSAL STIRRER for details see page 142 gt 24640 0 STIRRER ROTOR for 24600 0 stainless steel 21141 2 25000 5 SETA HOT 1000W electric heater variable heat control 21142 0 e for details see page 137 91113 e e 25300 0 MOULDING PLATE accepts two rings 21144 0 99100 2 ANALYTICAL BALANCE for details see page 141 21160 3 RINGS and BALLS 21170 0 e Refer to the table of ITEMS REQUIRED FOR EACH TEST and select from the 24500 0 e following options 24600 0 21140 0 SHOULDERED RING 15 inch wire stem pack of 3 24640 0 e e e e 21141 2 SHOULDERED RING pac
148. 2 OXIDATION CORROSION DUAL PURPOSE BATH m Oxidation Stability SETA OXI COR BATH ASTM D525 D873 D5304 IP 40 IP 138 BS 2000 Parts 40 and 138 ISO 2160 791 3352 791 3354 NF M07 012 NF M07 013 JIS K2276 Acccelerated Shelf Life Test for Dried Pet Food Also suitable for CORROSION TESTS to ASTM D130 D4048 D4814 Annex IP 112 IP 154 IP 227 obs IP PM DJ 2005 BS 2000 Parts 112 and 154 DIN 51 811 EN 2160 791 5325 NF M07 015 JIS K2513 Ambient to 150 C temperature range 3 oxidation test stations Oxidation tests including IP 40 Copper amp Silver corrosion tests A stainless steel water or oil bath with a temperature range of ambient to 150 C temperature controlled to 0 1 C by a top mounted thermostir circulator with integral over temperature and low fluid level protection The 15550 2 when used with the relevant accessories is an economic and versatile bath capable of carrying out oxidation and copper silver corrosion tests including IP 40 and ASTM D4814 The bath can accept up to three oxidation vessels Seta 15802 0 and accessories are available for three methods of pressure measurement ranging from a fully automatic pressure monitoring system to oxygen safe pressure gauges Further details on using the Oxi Cor as a corrosion bath are shown in the Corrosion amp Rust section on page 74 SUPPLIED WITH 4 lids mains lead and instruction manual A BIO FUEL TESTI
149. 2 obs ISO 3734 ISO 9030 FTM 791 Methods 3000 3003 3004 3101 3121 5661 DIN 51 793 NF M07 020 API 2542 API 2548 API MPMS Chapter 10 3 Specifically designed for testing oils Heated chamber ambient to 80 C 4 place swing out rotor Microprocessor control with 99 programme memory Membrane touch control panel Pre heat facility to ensure bowl is at test temperature prior to test Universal buckets for 12 5ml 6 and 8 inch glassware Static near vertical bucket positioning Conforms to safety requirements IEC 1010 1 1010 2 D Optional Setafuge Hazard Reduction System Optional trolley Seta Oil Test Centrifuge is a microprocessor controlled heated centrifuge manufactured exclusively for Seta by Hermle Labortechnik The instrument is fully programmable allowing automatic configuration to the specified oil test parameters A four place swing out rotor and universal bucket assembly accommodates low cost adaptors and cushions suitable for borosilicate glass centrifuge tubes of the types specified for oil testing 6 or 8 inch conical 8 inch trace sediment 8 inch pear shaped or 12 5ml To reduce errors in measurement of tube content the rotor design allows tubes to stand in a near upright vertical position at rest Speed temperature and timing are microprocessor controlled and run parameters are entered via the panel controls and digital displays Speed can be specified and measured in either RPM rotational speed or RCF
150. 2000Part40 66 68 69 74 BS2000Part48 70 BS2000Part49 5 5500 58 60 BS2000Part50 58 60 BS2000Part58 54 BS 2000 Part69 5 s 24 25 BS2000Part71 sss S2 34 36 38 BS2000Part7A 5 550 31 BS 2000 Part 104 obs B 5 119 123 BS 2000 Part 107 5 97 BS 2000 Part 121 106 BS 2000 Part 123 5 555 28 30 BS 2000 Part 3 87 BS 2000 Part 135 5 78 5 2000 138 66 68 69 74 BS 2000 142 5 5 69 BS 2000 Part 143 5 5 33 BS2000PartM46 5 102 BS 2000 Part lJ 5 5550s 68 74 BS 2000 Part 156 Ua 92 BS 2000 Part170 5 5 2 5 18 BS 2000 Part 179 5 58 60 BS2000Part 82 5 55 94 BS 2000 Part 191 5 s 28 30 BS 2000 Pari 195 5 28 30 BS 2000 Part 219 5 5 5 50 51 BS2000Part280 10 BS 2000 Part 300 70 BS 2000 Part 309 52 BS2000Part319 5 5 36 37 BS2000Part358 5 31 BS2000Part375 5 5 86 BS2000Part388 amp 5 13 BS2000Part398 84 BS2000Part402 obs h ss 24 BS2000Part403 obs 5 ss 2 6 19 2000 Part 404 obs m s 2 4 18 BS 2000 Part410 5 24 26 2000 Pat Ml 5 5 aa 76 77 118 3900 AB amp AQ 5 5 sss 2 5 17 BS 3900 PartAM 5o 16 BS 3900 Part A13 2 8 12 13 15 156 Method page BS 4382 obs 56 BS 4451 obs u a 85 POMI uuusssaasqaiyaqastsqaa panasqa a 32 34 cr BS 4714 obs
151. 2001 Pack of 5 11220 001 TEST SPECIMEN eM ASTM D665 Procedures A B amp C NACE TM0172 2001 CONFORMANCE CERTIFICATE WORKS A vertical test specimen with a ground finish Suitable for use with 11220 0 and 11290 0 Pack of 5 11220 001 11335 0 BEAKER COVER AND TEST SPECIMEN HOLDER ASTM 03603 05534 CONFORMANCE CERTIFICATE Comprises an acrylic beaker cover and holder suitable for use with we WORKS 11330 0 test specimens 11335 0 11330 0 PAIR OF TEST SPECIMENS ASTM D3603 D5534 CONFORMANCE CERTIFICATE uU lt WORKS Comprises one each vertical and horizontal test specimens with a ground finish an acrylic holder and a PTFE washer 11330 0 11225 0 SYNTHETIC SEA WATER SOLUTION 10 x 30ML 11227 0 SYNTHETIC SEA WATER SOLUTION 300ML ae ASTM D665 Procedure B A CONFORMANCE CERTIFICATE I WORKS 11227 0 Particulates Residues amp Composition FUEL PARTICULATES L SA1000 0 S VCOUNT PARTICLE COUNTER SA1200 0 S VCOUNTS PARTICLE COUNTER BATTERY POWERED ASTM D7619 Standard Test Method for Counting and Sizing Particles in Light and Middle Distillate Fuels and Liquid Bio Fuels by Automatic Particle Counter IP 565 DEF STAN 91 91 ISO 4406 1999 prEN 60970 2006 Fully automatic operation Particle size 4um to gt 70um ISO 11171 Cumulative amp distributive particle numbers ISO 4406 1999 codes Uses Straight from the Bottle samples Internal Double Pump System Built in p
152. 203 25000 3 11860 207 25000 302 26500 0 26500 001 30000 0 13730 005 13740 004 13740 009 13740 017 13740 425 13770 004 13770 311 30000 001 30000 002 30000 003 30000 004 30000 005 30000 006 30000 007 30000 008 30000 009 70000 001 80000 024 31000 0 13730 005 13740 009 13740 017 13770 311 30000 002 30000 004 30000 005 30000 006 30000 007 30000 008 31000 001 31000 002 80000 024 33000 0 13730 005 13740 004 13740 009 13740 017 13740 425 13770 004 13770 311 30000 002 30000 003 30000 004 30000 005 30000 006 30000 007 30000 008 30000 009 33000 001 70000 001 80000 024 33200 2 13730 005 13740 004 13740 009 13740 017 13740 425 13770 004 13770 311 30000 002 30000 004 30000 007 30000 008 30000 009 33200 201 33200 202 33200 203 33200 204 70000 001 80000 024 33250 2 13730 005 13740 004 Page Quick fit Connector Hose for Manometer Seta Hot 137 Energy Regulator Heater Assembly 1000W Burning Rate Test Rig 21 Duratec Block Series 3 Closed Cup Tester 13 Silicone Rubber Tube 4 metres Sample Well Seal Ring Viton pack of 5 Syringe 2ml Heat Sink Compound Flash Detector Assembly Sample Well Seal Ring Silicone pack of 5 Syringe 4ml Controller PCB Gas Tank Closed Cup Sample Block Front Panel Assembly Over Temperature Cut Out Wiring Set Rubber Feet set Service Screw Set Locking Post for Lid Lid amp Shutter Assembly Fuse 2A pack of 10 Seri
153. 2384 97 02386 52 150 Method Number Method page ASTM D2416 89 ASTM D2420 143 ASTM D2440 Rm 10 73 ASTM D2500 a DO 51 190 151 ASTM 02533 e 22 ASTM D2547 obs za ASTM 02569 143 MM 98 99 ASTM D2622 s 152 153 ASTM D2624 115 ASTM D2699 151 MTS 151 ASTM D2708 108 ASIM OZI NND 108 ASTM D219 o ossessi 117 N 98 99 ASTM 0278497 ASTM D2884 e 298 ASTM 02887 153 scr ee 44 45 ASTM 03227 t 150 ASTM D3230 2d 107 T MEME 143 150 ASTM 03278 aaa 2 8 10 13 15 156 115 ASTM D3413 17 MEME 104 ASTM 03603 78 73 ASTM D MM 152 AST MDI cctools 143 HU ore 2 8 10 13 15 156 ASTM D3830 0 82 ASTM Dr ASTM D3941 sc Dou MEME 31 ASTM DOOF issu Didi 108 ASTM D4048 687476 ASTM DAM 121 D ine asians 98 99 ASTM D4206 rt 16 uc c MM 47 294 c 152 153 MTM 121 ASTM DATO aaa 69 73 143 ASTM D4530 o 151 l c NNNM 10 ccc sm 64 65 ASTM D4814 cc 68 74 76 77 ASTM D4870 e 86 ASTM DABIT 10 Was 22 24 ASTM D5125 rz 47 DIL 22 ASIM ISTA 22 23 151 68 74 ASTM D5386 2 ASTM D5452 A 82 ASTM 05453 e 152 22 23 ASTM 05584 18 73 ASTM D5548 A08 SL MEME 10 don ASTM D5772 190 ASTM D5773 140 ASTM 05846 10 73
154. 3 0 REDWOOD No 1 VISCOSITY KIT 46 83255 0 REDWOOD No 2 VISCOSITY KIT 46 83257 0 BITUMEN VISCOSITY KIT 46 83541 3 SETAVIS KINEMATIC VISCOMETER 34 83542 0 SETAVIS DOUBLE 6 KINEMATIC VISCOMETER 34 83545 3 SETAVIS DOUBLE 6 KINEMATIC AUTO VISCOMETER 32 83570 0 BACK FLUSH KIT 33 35 83575 2 6 WAY AUTOCLEAN FITTING KIT 33 83578 2 TWO STAGE WASTE EXTRACTION SYSTEM 33 83582 2 SETAVIS SOLVENT CONTAINER 33 83600 0 KINEMATIC VISCOMETER TUBES set of nine 35 83600 001 KINEMATIC VISCOMETER TUBE 35 83600 002 KINEMATIC VISCOMETER TUBE 35 83600 003 KINEMATIC VISCOMETER TUBE 35 83600 004 KINEMATIC VISCOMETER TUBE 35 83600 005 KINEMATIC VISCOMETER TUBE 35 83600 006 KINEMATIC VISCOMETER TUBE 35 83600 007 KINEMATIC VISCOMETER TUBE 35 83600 008 KINEMATIC VISCOMETER TUBE 35 83600 009 KINEMATIC VISCOMETER TUBE 35 83602 0 BITUMEN KINEMATIC VISCOMETER TUBES set of six 35 83602 001 BITUMEN KINEMATIC VISCOMETER TUBE 35 83602 002 BITUMEN KINEMATIC VISCOMETER TUBE 35 83602 003 BITUMEN KINEMATIC VISCOMETER TUBE 35 Index Product Number Part Number 83602 004 BITUMEN KINEMATIC VISCOMETER TUBE 83602 005 BITUMEN KINEMATIC VISCOMETER TUBE 83602 006 BITUMEN KINEMATIC VISCOMETER TUBE 83605 003 X SETAVIS KAV AUTO DUPLEX TUBES 83605 004 SETAVIS KAV AUTO DUPLEX TUBES 83605 005 SETAVIS KAV AUTO DUPLEX TUBES 83605 006 SETAVIS KAV AUTO DUPLEX TUBES 83605 007 SETAVIS KAV AUTO DUPLEX TUBES 83605 008 SETAVIS KAV AUTO DUPLEX TUBES 83605 009
155. 30 C temperature range Accepts up to 12 SimAir test cells Internal refrigeration unit Mounting for Brookfield Viscometer The 94830 3 is a liquid filled refrigerated viscometer bath that when used in conjunction with patented SimAir test cells and a Brookfield LV type rotational viscometer meets the requirements of tests to ASTM D2983 A digital temperature controller 600W heater and refrigeration unit allows a bath temperature range of 40 to 30 C with a stability of 0 1 C The refrigeration system uses R507 a non CFC and non ozone depleting refrigerant and is capable of a cool down rate of approximately 20 C hr An internal air flow system provides a blanket of warm air to protect the sample from moisture and prevent condensation build up on the oversize back lit viewing window BLE In the event of a brief power interruption a power saver facility allows the test to resume after power is restored Safety devices include over temperature high pressure and low bath fluid cut outs The casing is manufactured from stainless steel and thermoplastic Mounting points for a Brookfield LV viscometer are situated on the top of the bath and a 12 position carousel allows for rapid changeover between samples SUPPLIED WITH viscometer mounting bracket 12 position carousel insulated flask lid carousel port plugs moisture cover stirrer bar spindle storage block mains lead and instruction manual Notes Supplied
156. 31 0 AirP 136 b 11910 004 Receiver Crow type pack of 2 inp m 16155 406 re Cut out 12200 3 GO AONA BIDEE Balh 8 14060 0 Twin Column Adsorption Apparatus 92 12200 002 Conical Air Outlet Adaptor 11220 0 Vertical Test Specimen 79 12200 003 Beaker 100ml pack of 20 14060 001 Ultra Voilet Fluorescent Tube i 14060 901 Scale amp Cursors pair 11220 001 Test Specimen pack of 5 12200 004 Flow Gauge Uncalibrated id si 11220 002 Holder Acrylic pack of 5 12200 301 Digital Temperature Controller E co i A 11220 003 Cover pack of 2 12200 302 Heater 14090 903 Measuring Scale i ssembly 11300 0 Copper Corrosion Bath 75 12200 305 Temperature Probe 14080 0 Standard Adsorption Column 92 15155 006 Fuse pack of 5 12200 306 Overtemperature Cutout DIE jr iod m sie 15155 201 Heater 5 4 nalyser Section pack o 15155 202 Stirrer Motor 0310 50 ana Gasket 7 ee d ack of 2 15155 204 Power PCB 12310 302 Safety Valve 080 003 E ee of 2 15155 205 Display PCB 12310 303 Pressure Switch eats aie CDs Pat Oho 11305 0 Copper Corrosion Bath 75 12310 304 Feedwater Pump 14090 0 True Bore Adsorption Column 92 15155 006 Fuse pack of 5 12600 0 Portable Density Measurement Kit 135 beides m adh pack of 2 12600 001 Density Standard 100ml pac 15155 202 Stirrer Motor 12600 002 Density Standard 100ml 14090 002 a eparator Analyser Section i Bus PER ss ONN 14090
157. 3C Precision 8 to 32 C 0 1 C 379 28C 31 Kinematic Viscosity 36 6 to 39 4 C 0 05 C total 305 63F Precision 18 to 89 F 0 2 F total 379 28F 31F Kinematic Viscosity 97 5 to 102 5 F 0 1 F total 305 64C Precision 25 to 55 C 0 1 C total 379 29C 34C Kinematic Viscosity 52 6 to 554 C 0 05 C total 305 64F Precision 77 to 131 F 0 2 F total 379 29F 34F Kinematic Viscosity 127 5 to 132 5 F 0 1 F total 305 65C Precision 50 to 80 0 1 C total 379 65F Precision 122 to 176 F 0 2 F total 379 30F 32 Kinematic Viscosity 207 5 to 212 5 F 0 1 F total 305 66 Precision 75 to 105 C 0 1 C total 379 33C 20C Low Aniline Point 38 to 42 C 0 2 C 50 420 66F Precision 167 to 221 F 0 2 F total 379 ASTM amp IP Thermometers Temperature amp Fluid Density CONFORMANCE CERTIFICATE To order a thermometer with a works conformance certificate quote the IP or ASTM part number i e IP39C CALIBRATION CERTIFICATE UKAS order a thermometer with a UKAS calibration certificate 200 the suffix Z to the IP or ASTM part number i e IP39CZ ASTM IP APPLICATION TYPE RANGE A B C IP APPLICATION TYPE RANGE A B C 67C Precision 95 to 155 C 0 22C total 379 102C 83C Solvents Distillation 123 to 177 C 0 2 100 395 67F Precision 203 to 311 F 0 5 F X total 379 103C 84C Solvents Distillation 148 to 202 C 0 2 C 100 395 68C Precision 145 to 205 C 0
158. 4 5psi Power 2 2KW maximum heat Voltage 110 20V 50 60Hz 220 240V 50 60Hz Size HxWxD A1 x41 x 23cm Weight 25kg CRYOSTATS 94000 2 99300 2 General Laboratory Equipment Cooling CD DRY ICE MAKERS Dry ice liquid mixtures can produce temperatures down to 78 C The latent heat of vaporization of dry ice is 572 kJ kg 246 BTU per Ib Seta dry ice makers are a safe efficient and convenient method of producing pellets and blocks in a range of sizes 70200 0 SNOWPACK DRY ICE MAKER e Makes 30g 102 pellet in one minute Fits directly to CO syphon cylinder f nmmnimin A w LE Size HxWxD 27 x 15 9 Weight 0 6kg 70210 0 70210 0 SNOWPACK MAJOR DRY ICE MAKER e Makes 500g 110 pellet in 2 1 2 minutes Fits directly to CO cylinder Size HxWxD 28 15x 15cm Weight Nr 70220 3 PORTABLE DRY ICE MAKER MODEL B e Makes 1kg 2 216 block in one minute Fits directly to CO cylinder SUPPLIED WITH pressure hose and gauge 70220 3 Main Unit and Hose Gauge Assembly d S ui 1 im ll Ir LUII JA UIN O Size HxWxDJ 23 X 16 X 12cm Weight 3 3kg REFRIGERATED STORAGE 93700 2 LABORATORY REFRIGERATOR Temperature range 0 to 10 C ISPECIFICATIONS Cool storage of volatile materials Compart
159. 42 142 29 85 103 85 29 85 103 29 85 103 78 79 78 19 78 16 77 118 78 78 78 78 79 75 75 75 78 79 79 74 76 76 76 76 16 77 118 64 72 16 77 118 16 77 118 16 51 76 16 16 16 77 16 16 77 118 16 16 77 118 16 77 118 Part Number 11800 0 DISTILLATION UNIT 11804 0 FLEXIBLE STOPPER CAP pack of 10 11805 0 GAS CONTROL VALVE 11806 0 THERMOMETER CENTRING DEVICE 11807 0 THERMOMETER CENTRING DEVICE 11808 0 CERAMIC GLASS FLASK SUPPORT BOARD 11809 0 CERAMIC GLASS FLASK SUPPORT BOARD 11810 0 CONDENSER UNIT 11811 0 CERAMIC GLASS FLASK SUPPORT BOARD 11812 0 CERAMIC GLASS FLASK SUPPORT BOARD 11813 0 CERAMIC GLASS FLASK SUPPORT BOARD 11814 0 CORK pack of 100 11815 0 CORK pack of 100 11850 0 SETAMATIC CONTROLLED HEATER 11860 3 SETASTILL 11865 3 CONDENSER LID 11866 0 ANTI SPLASH PLATE pack of 3 11867 0 TEMPEN DIGITAL THERMOMETER 11868 0 HEAT SHIELD SETASTILL 11869 0 D86 DISTILLATION KIT 11869 002 BOILING STONES pack of 3 11890 0 DISTILLATION FLASK 125ml pack of 5 11900 0 ASPHALT DISTILLATION APPARATUS 11910 0 GLASSWARE 11910 004 RECEIVER 100ml pack of 2 11920 0 RESIDUE CONTAINER pack of 5 11940 0 DISTILLATION FLASK 125ml NS type pack of 5 11950 0 DISTILLATION FLASK 100ml pack of 5 11960 0 DISTILLATION FLASK 200ml pack of 5 11962 0 DISTILLATION FLASK 200ml pack of 5 11970 0 DISTILLATION FLASK 250ml pack of 5 12200 3 EXISTENT GUM
160. 5 to 15 C 0 1 C total 300 83F Fuel Rating Air 60 to 160 F 1 F 40 171 125C 97C Brookfield Viscosity 15 to 5 C 0 1 C 300 84C Fuel Rating Orifice Tank 25 to 80 C 1 C 249 383 em 126C 71C Kinematic Viscosity 27 4 to 24 6 C 0 05 C total 305 84F Fuel Rating Orifice Tank 75 to 175 F 1 F 249 383 mm 126F 71F Kinematic Viscosity 17 5 to 12 5 F 0 1 F total 305 85C Fuel Rating Surge 40 to 150 C 1 C 181 310 127C 99C Kinematic Viscosity 21 4 to 18 6 C 0 05 C total 305 85F Fuel Rating Surge 100 to 300 F 2 F 181 310 128C 33 Kinematic Viscosity 14 to 1 4 C 0 05 C total 305 86C Fuel Rating Mix 952 fton 2526 1 C 35 167 128F 33F Kinematic Viscosity 29 5 to 34 5 F 0 1 F total 305 86F Fuel Rating Mix 200 to 350 F 2 F 35 167 e 129 36C Kinematic Viscosity 91 6 to 944 C 0 05 C total 305 87C Fuel Rating Coolant 150 to 205 C 1 40 172 r 129F 36 Kinematic Viscosity 197 5 to 202 5 F 0 1 F total 305 87F Fuel Rating Coolant 300 to 400 F 1 F 40 172 88C Vegetable Oil Flash 10 to 200 C 1 C 57 287 130 Tank 7 to 105 C 0 5 C total 303 88F Vegetable Oil Flash 50 to 392 F 2 F 57 287 MEE 130F Tank 20 to 220 total 303 89C Solidification Point 20 to 10 C 0 1 C 76 370 132C 102 Kinematic Viscosity 148 6 to 1544 C 0 05 C total 305 TM 133C Precision 38 to 2 C 0
161. 5 83540 001 83540 008 83540 009 83540 012 83540 019 83540 021 83541 301 83541 302 83541 304 83541 305 83545 001 83545 002 83545 003 83545 004 83545 005 83545 006 83545 007 83545 050 83575 002 83575 004 83575 201 83575 203 83575 2 83575 201 83575 203 spare Parts Page Flash Detector Ignitor Keypad Keypad Gasket Servo Display PCB Display Display Ribbon Cable Peltier PCB Ignitor PCB Main PCB Fuse 5A pack of 5 Lid amp Shutter Programming Plug Battery Cell pack of 2 0 Ring Saybolt Redwood Viscometer Bath 46 Thermal Cut out Supply Switch Temperature Probe Ball Valve for Redwood Cups pack of 2 Thermometer Collar pack of 2 Gasket for Redwood No 1 Cup pack of 20 Gasket for Redwood No 2 Cup pack of 5 Digital Temperature Control Main PCB Heatsink PCB Triac Assembly Connecting Lead 2 metres Temperature Indicator Gasket pack of 10 Wire 100 Mesh Setavis Kinematic Viscometer 34 Setavis Double 6 Kinematic Viscometer 34 Knob for Fine or Clean control Mains Lead 0 Ring Pipe Seal pack of 10 Temperature Indicator Assembly Dual Heater Assembly Drain Trap Borosilicate Glass Tubing 3mm i d 3 metres Tubing 5mm i d 3 metres Tube Gland pack of 6 Bath Assembly Neon Indicator Light Clear Solenoid Valve for Vacuum Vent PRT Probe Assembly Tube Dust Cover pack of 24 Vacuum Pump Internal Heater Driver Circuit Board Assembly Temperature Control Circuit Boar
162. 5 0ml 0 1ml 6 to 25ml Round B19 Cone B24 Cone IP 291 ASPHALT DISTILLATION SETA ASPHALT DISTILLATION APPARATUS ASTM D402 IP 27 BS 2000 Part 27 NF T66 003 obs AASHTO T78 obs Gas heated Stand mounting Apparatus for measuring the volume of volatile constituents in cutback asphaltic products Comprises a heat insulated shield two part insulated cover and two sheets of 16 mesh gauze supported on a height adjustable platform A steel chimney below the shield reduces heat loss from the gas burner not supplied Stand mounting ACCESSORIES Asphalt Distillation REQUIRED 11910 0 GLASSWARE comprises 500ml side arm distillation flask glass jacketed standard condenser adaptor spout and 100ml Crow receiver RESIDUE CONTAINER 80z with slip on cover pack of 5 SETA STEEL STAND for mounting apparatus two required 24520 0 CLAMP to secure condenser to bosshead 24650 2 BOSSHEAD to secure clamp to stand AND ONE OF THE FOLLOWIING 13401 0 SETA BURNER for natural gas methane 13402 0 SETA BURNER for LPG 13403 0 SETA BURNER for coal gas THERMOMETERS ASTMB8C IP6C or ASTM8F 11920 0 24500 0 11900 0 and Accessories 11900 0 Burner glassware and stands supplied separately SPECIFICATIONS CONSUMABLES Asphalt Distillation 2 2000 Tests Qt 11910 001 DISTILLATION FLASK pack of 2 11910 004 RECEIVER CROW TYPE pack of 2 Viscosity Kinematic Capillary 83545 3 SE
163. 5 SETA SINGLE VALVE SAMPLING CYLINDER 100ml Maximum working 20560 0 pressure 46 bar 670 Ibf in 20565 0 e 20490 0 COMPLETE SET OF GLASSWARE comprising five standard burners with 20570 0 e e flasks chimneys absorbers and splash bulbs three pressure regulators 20580 0 e and two scrubbers and levelling bulbs with interconnecting tubing For all 21520 3 e methods 21790 0 20540 3 REGULATING VALVE with tubing 21800 0 o e 20550 0 FLASK for aromatic samples pack of 2 22150 2 20560 0 BURNER for aromatic samples pack of 2 IP76C e e 20565 0 MANIFOLD with five valves for aromatic samples 20570 0 BLAST BURNER for LPG samples pack of 2 20580 0 BLAST BURNER for fuel gases pack of 2 21520 4 SETA DOUBLE VALVE SAMPLING CYLINDER 50ml capacity Maximum working pressure 46 bar 670 Ibf in 21770 0 SETA RELIEF VALVE high pressure Fit to Sampling Cylinder for maximum safety Set to relieve at 46 bar 670 Ibf in 21790 0 SETA QUICK CONNECTION COUPLING high pressure male Hansen Fits directly to Sampling Cylinder or Seta Relief Valve 21800 0 SETA QUICK CONNECTION COUPLING high pressure female Hansen Fits directly to 20540 3 22750 2 DIGITAL STOPWATCH hand held 0 1s resolution for details see page 141 99100 2 ANALYTICAL BALANCE for details see page 141 THERMOMETERS IP76C Note Other items which may be required include Titration or photometric equipment Chemicals Oxygen Cardo
164. 50 22422 6 VACUUM PUMP 22430 3 PRE PRESSURISED MANOMETER 22460 0 MANOMETER ADAPTOR pack of 2 22470 3 MANOMETER 22490 0 GAUGE ADAPTOR pack of 2 22500 0 PRESSURE GAUGE 22510 0 PRESSURE GAUGE 22520 0 PRESSURE GAUGE 22530 0 PRESSURE GAUGE 22540 0 PRESSURE GAUGE 22550 0 PRESSURE GAUGE 22560 0 PRESSURE GAUGE 22561 0 PRESSURE GAUGE 22570 2 PRESSURE GAUGE 22580 2 PRESSURE GAUGE 22590 2 PRESSURE GAUGE 22620 2 REDWOOD No 1 VISCOMETER 22650 0 ENERGY REGULATOR 22680 0 HYDROMETER 22690 0 HYDROMETER 22705 0 THERMO HYDROMETER 22710 0 THERMO HYDROMETER 22120 0 THERMOMETER 22130 0 THERMOMETER 22150 2 DIGITAL STOPWATCH 22950 2 TRI GAUGE VISCOSITY COMPARATOR 23150 2 UNIVERSAL VISCOMETER HOLDER 23152 0 VISCOMETER HOLDER 23154 0 VISCOMETER HOLDER 23156 0 VISCOMETER HOLDER 23210 2 TAR VISCOMETER 23215 0 AFNOR FLOW CUP 23216 0 AFNOR FLOW CUP 23217 0 AFNOR FLOW CUP 23340 2 FORD NO 2 JET 23350 2 FORD NO 3 JET 23360 2 FORD NO 4 JET 23510 0 B FLOW CUP No 6 JET 23520 0 PROTECTIVE COLLAR FOR TYPE B AND FORD CUPS 23540 0 BS ISO FLOW CUP NO 5 23550 0 BS ISO FLOW CUP NO 4 23560 0 BS ISO FLOW CUP NO 3 23570 0 B FLOW CUP No 2 JET 23580 0 B FLOW CUP No 3 JET 23590 0 B FLOW CUP No 5 JET 23600 0 B FLOW CUP No 4 JET 23610 0 BS ISO FLOW CUP NO 6 23611 0 BS ISO FLOW CUP NO 8 23660 0 STAND 23661 0 SIGHT SCREEN FLOW CUP 23680 0 SPIRIT LEVEL 23750 0 ZAHN CUP NO 1 23760 0 ZAHN CUP NO 2 23770 0 ZAHN C
165. 50ml syrup bottle SA1014 0 500ml BOTTLE CARRIER for SA1010 0 SA1016 0 ADJUSTABLE BOTTLE CARRIER up to 1000ml syrup bottle fits SA1010 0 SA1020 0 5 litre TUMBLER SA1022 0 SAMPLING KIT 32 5mm bung 300mm tube length SA1001 0 CALIBRATION FLUID 250m bottle with certificate SA1006 0 VERIFICATION FLUID 250ml bottle with certificate 99320 2 SETA ULTRASONIC CLEANING BATH for details see page 142 SA1030 0 AvCOUNT SERVICE KIT SA1035 0 AvCOUNT TOOL KIT SA1100 0 SERVICE AND CALIBRATION CONSUMABLES AvCOUNT PARTICLE COUNTERS SA1000 003 PRINTER PAPER SA1000 0 amp SA1200 0 pack of 10 rolls 2 5 030 0 Av COUNTS ER VAC oce ecc nan 2 80 44 0 1932 564391 LF 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk Particulates Particulates Residues amp Composition I X SeraAnalulics SA1000 2 PARTICLE COUNTER ASTM D7619 Standard Test Method for Counting and Sizing Particles in Light and Middle Distillate Fuels and Liquid Bio Fuels by Automatic Particle Counter IP 565 DEF STAN 91 91 ISO 4406 1999 ISO 4406 1991 GOST 17216 NAS 1638 SAE AS4059E SAE A6D SAE 749D GB 5930 GJB 420 1987 GJB 420 A 1996 GJB 420B 2006 All the features of the original AvCount plus Easy to use large colour touch screen display 15 fixed measuring channels Additional particle counting methods Save up to 2000 measurements a
166. 50ml Beaker 600ml Beaker 1 litre Beaker Watch Glass and Tubing SOAFLAB FILTRATION KIT ASTM 05452 IP 423 Filtration test for Aviation Fuels Comprises 0 45 micron Filter matched weight pair of 0 8 micron Filters stainless steel Filter Holder with stainless steel screen Filter Forceps 25mm Solvent Filtering Dispenser Vacuum Filtering Flask and Petrislide 16160 2 Mounting Tray and Monitor Cases supplied separately jm DEN ACR TRY aS IL eat AL A 16165 2 16170 0 16180 0 16190 0 16210 0 16220 0 16230 0 99200 2 45000 0 COLOUR RATING BOOKLET ASTM each colour reference is certified by MOUNTING TRAY supplied with compression fittings suitable for connection to 1 4 inch o d fuel line MONITOR CASE reuseable pack of 48 FILTER 37mm dia 0 8um AND SUPPORT PAD disposable pack of 100 OR MONITOR REFILL matched weight with thick absorbent pads Alternative to 16180 0 avoids need to initially weigh the filter pack of 50 B ANT A JI 16200 0 Munsell Colour to standards for chroma value and hue and laminated for fuel resistance In accordance with ASTM D2276 IP 216 D3830 obs COLOUR AND PARTICLE RATING CHART 33 colour and 9 particulate photographs on one chart Colours in accordance with ASTM D2276 IP 216 and particulate references by permission of Shell Oil TWEEZERS with blunt points and slip lock to grip filters pac
167. 5C ASTM40C IP80C ASTM41C IP81C IP22C D2440 D4636 D5763 D5846 D6514 EN 61125C e e 11 Oxidation Oxidation Stability SOLID BLOCK OXIDATION BATHS 16640 0 SETA TOST BATH 12 WAY ASTM D943 ASTM D7472 Oxidation Stability of Biodiesel Blends B100 and Blends of Biodiesel with Middle Distillate Petroleum Fuel Accelerated Method IP 157 ISO 4263 DIN 51 587 NF T60 150 TOST Test Alternative to ASTM D2274 IP 388 and ISO 12205 12 positions Dry block bath Ambient to 100 C temperature range Integral Setatemp controller Seta Oxflo Controller and flowmeters included A compact solid block bath which can accept up to 12 sets of oxidation glassware and is suitable for TOST tests and as an alternative to liquid filled baths The layout of the heating elements give an even temperature distribution and the integral Setatemp 50K Temperature Controller ensures stability over 16640 0 Glassware supplied separately extended test times Safety features include an over temperature cut out The Seta Oxflo Controller supplied comprises an inlet pressure regulator pressure gauge and six precision flowmeters with tubes and Sy floats calibrated for oxygen at 3 litres hour 21 C and 0 4bar pressure D BIO FUEL TESTING SUPPLIED WITH 6 place Seta Oxflo Controller with gas inlet pressure regulation pressure gauge and six precision flowmeters calibrated at 3 litres hr CALIBRATION CERTIFICATE
168. 6 18105 0 PENETRATOR KIT NO 5 60 21310 0 BASKET THIMBLE SUPPORT 86 18106 0 PENETRATOR KIT NO 6 60 21320 0 WATER CUP pack of 5 86 18107 0 PENETRATOR KIT NO 7 60 21400 0 MELTING POINT APPARATUS 56 18108 0 PENETRATOR KIT NO 8 60 21501 3 PROTECTION COLLAR 119 123 18109 0 PENETRATOR KIT NO 9 60 21502 2 PROTECTION COLLAR 119 123 18110 0 PENETRATOR KIT NO 10 60 21520 4 DOUBLE VALVE SAMPLING CYLINDER 50ml 97 119 127 18120 0 SAMPLE CONTAINER PETROLATUM 61 21530 4 DOUBLE VALVE SAMPLING CYLINDER 100ml 119 123 18140 0 STANDARD CONE 60 21540 4 DOUBLE VALVE SAMPLING CYLINDER 200ml 119 123 18150 0 CUTTER FOR BLOCK GREASES 62 21550 4 DOUBLE VALVE SAMPLING CYLINDER 250ml 119 123 18160 0 CENTRALISING COVER 62 21560 5 DOUBLE VALVE SAMPLING CYLINDER 500ml 119 123 18200 5 WATER BATH 59 61 21600 4 DOUBLE VALVE SAMPLING CYLINDER 1000ml 119 123 18203 0 COOLING UNIT WITH COIL 61 21620 4 DOUBLE VALVE SAMPLING CYLINDER 2000ml 119 123 18204 0 COOLING COIL 61 21690 4 DOUBLE VALVE SAMPLING CYLINDER 4000ml 119 123 18470 0 SAMPLE CONTAINER BITUMEN 61 21711 0 BACON SAMPLING VESSEL 950ml 121 18480 0 TEST SPECIMEN CONTAINER WAX 61 217120 BACON SAMPLING VESSEL 475ml 121 18481 0 BRASS BASE PLATE 61 21715 0 EXTENDER ROD 7 5cm long 121 18490 0 WAX PENETRATION NEEDLE 60 21716 0 EXTENDER ROD 15cm long 121 18492 0 WAX PENETRATION NEEDLE 60 21717 0 X EXTENDER ROD 30cm long 121 18500 0 NEELE 60 21718 0 EXTENDER R
169. 60 0 5 secs or 1 hour 60 1 min 4 8 and 20 hours 15 or 40 0 2 6 to 800 510 20 Weld Load WL Mean Hertz Load MHL Scar Diameter MSWD Seizure Load ISL Lubricating Oils Scar diameter Lubricating Fluids Lubricating Oils Polymer CONSUMABLES 4 Ball Lubricant Testers 2 Years 2000 Tests 19800 002 TEST BALLS DIN 5401 Pack of 1200 19800 024 THRUST RACE PLUNGER HEAD 19800 025 THRUST RACE BEARING HEAD 19800 036 BALL CHUCK 19910 001 CHART ROLLS 19900 2 with 19910 0 fitted only Tribology amp Bearing Lubrication BEARING GREASE TESTERS fm 19400 3 19610 4 SETA ROLL STABILITY TESTER ASTM D1831 MIL G 10924 10rev min and 165 rev min Air bath temperature range ambient to 150 C Integral timer Four test cylinder capacity The Seta Roll Stability Tester simulates the effect of squeezing grease between the rollers and the outer race of a roller bearing Up to four test cylinders each containing a heavy roller is loaded with the sample grease and placed horizontally upon a set of drive wheels that rotate the cylinders at either 10 or 165 rev min A digitally controlled fan assisted air bath provides evenly distributed heating up to 150 C and an integral timer is used to set the test duration CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE SPECIFICATIONS Bearing rotational speed 10 or 165 rev min Ambient to 150 C Tempe
170. 6155 405 99600 2 99610 2 99620 2 99600 004 99600 005 99600 006 99700 4 99700 301 99700 302 Page Low Temperature Viscosity Bath 38 Spares Kit Low Temperature Viscosity Bath 38 Temperature Probe Heating Element pack of 2 Stirrer Herschel Emulsifier 105 Stirrer Motor Thermostir Stainless Steel Stirrer Power Supply PCB Digistill Thermometer amp Data Processor 30 Fuse Digistill Temperature Probe Command Button and Cable 3V Battery Connection Cable without probe Schilling Effusiometer Glass Cylinder Outer Glass Cylinder Inner Orifice Plate Rubber Ring pack of 5 Glassware Seal Ring pack of 5 Cover with 3 Valves Valve set of 3 Micro Carbon Residue Tester 84 Condensate Trap pack of 2 Packing for Trap Circuit Protector Cooling Fan Oven Seal Insulation Freeze Valve 117 Filter Element amp Gasket Body Gasket pack of 5 Connecting Screen pack of 10 Retaining Ring pack of 10 Compression Spring Cold Filter Plugging Point CFPP App 52 Test Jar Graduated at 45ml Insulating Ring pack of 2 Spacer Ring pack of 10 Pipette Sealing Gasket Pipette pack of 10 Sealing Gasket Filter pack of 10 Filter Gauze Thermometer Clip Filter in Mount Three way Cock Cooling Bath U tube Manometer Equilibrium Bottle amp Fittings Ash Furnace 84 Porcelain Crucible tall form 100ml pack of 5 Porcelain Crucible tall form 120ml pack of 5 Mini Low Temperature Bath C
171. 7 8 C Correlates with ASTM D323 D2533 D4953 D5482 D6378 IP 69 IP 402 obs ISO 3007 EN 12 obs JIS K2258 NF M07 079 Five vapour pressure modes including Reid Vapour Liquid ratio mode Automatic operation Selectable units Integral printer RS232 interface CALIBRATION amp VERIFICATION MATERIALS TECHNICAL DATASHEETS AVAILABLE OS An automatic multi mode vapour pressure tester with a pressure range of 0 to700kPa 0 to 100psi and a temperature range of 25 C 45 F below ambient to 100 C 212 F Five vapour pressure test modes including a Reid vapour pressure mode allow single or multiple vapour pressure tests to be carried out on a sample at static ramping or stepped temperatures A vapour liquid mode enables the user to determine the temperature required to produce a pre set pressure All functions are accessed via a membrane keypad digital display while audible and visual prompts advise the status of the instrument and progress of the tests Units of pressure can be presented in kPa psi Ibf in2 kg cm2 mbar mmHg or inHg and units of temperature can be setto C or F The Setavap Analyser is fully automatic apart from the injection of sample To ensure gas tight operation the septum is in strip form and automatically advances for each test A septum strip is sufficient for up to 50 tests At the end of the test the sample is automatically drained and the test results with time date and s
172. 81000 004 81000 005 81000 006 81000 007 81000 008 81000 013 81002 201 81003 0 81003 001 81003 002 82000 0 82000 001 82000 002 82000 003 82000 004 82000 005 82000 006 82000 007 82000 008 82000 009 82000 010 82000 011 82000 012 82000 013 82000 014 82000 015 82000 016 82000 018 82100 0 82000 001 82000 002 82000 003 82000 004 82000 005 82000 006 82000 007 82000 008 82000 009 82000 010 82000 011 82000 012 82000 014 82000 015 82000 016 82000 018 82150 0 spare Parts Page O Ring Vacuum Pipe Seal pack of 10 0 Ring Transducer Seal Temperature Probe Printer PCB Mother PCB Paper Ink Package Interface PCB CPU PCB Regulator PCB Chamber Assembly PCB 0 Ring for Chamber Lid 0 Ring for Bottom Tube in Chamber Ball Valve Motor Gearbox for Ball Valve Opto Sensor for Ball Valve Heater Cooling Drive Transistor Kit Thermal Cutout Chamber Printer Unit Membrane Keyboard Assembly Fan 115V for Heatsink Fan 12V for Cabinet Septum Strip pack of 5 Flask Used Sample pack of 5 Temperature Probe Flexible Hose Vacuum Inlet to Ball Valve Chamber Assembly Thermal Cutout Heatsink Viton O Ring for Transducer Seal Eprom Fuse 2A 20mm pack of 10 Transducer Syringe 1ml c w LeurLock and needle Syringe 5ml c w LeurLock Needle for 81003 001 pack of 2 Setavap 2 23 Septum pack of 250 Display Unit Chamber Solenoid Valve Waste Container Drain Solenoid Valve Septum Holder Base Mo
173. 81002 2 DATA PRINTER Measurement range 0 250 mg kg H S in the liquid phase 0 250 ppm HS SA4004 0 PIPETTE gt 20ppm samples Jo SA4007 0 CARRY CASE ting limits i 0 Operating limis _ Co n d SA4008 0 TEST VESSEL WARMER Up to 3000 mm s at 40 C SA4010 0 PC CONNECTIVITY KIT Viscosity range Principal of measurement Advanced Electrochemical Sensor PALIRRATIN Test duration rnis SA4011 0 AIRFLOW CALIBRATION VERIFICATION TOOL Sample size 1ml 2ml 5ml depending on H S concentration A Aaa Diluent volume 20ml Computer Interface RS232 CONS L H alyse r Power 60W maximum w SA4005 0 CONSUMABLE KIT for 180 tests comprising test vessels 8 x 500m diluent voltage o 12V DC supplied with universal A C transformer 200 disposable syringes and 2 m silicone tubing Size HxWxD 21 x 30x 41cm SA4006 0 ANNUAL SERVICE KIT comprising carbon filter particulate filters and tubing kit Weight 8kg Composition Particulates Residues amp Composition An instrument for measuring the presence of all FAME types in AVTUR E SersAnalulics SA5000 0 FIJI FAME IN JET INSTRUMENT IP PM DT Determination of the fatty acid methyl esters content of aviation turbine fuel with Fourier Transform Infrared spectroscopy Rapid screening method Measures the presence of all FAM
174. 86 IP 123 EN ISO 3405 220 to 247 C 100ml Distillation FBP D86 IP 123 EN ISO 3405 244 to 268 C 100ml Distillation Residue D86 IP 123 EN ISO 3405 1 1 to 1 3 vol 100ml Distillation Loss D86 IP 123 EN ISO 3405 0 4 to 0 8 vol 100ml Flash Point IP 170 EN ISO 13736 35 to 60 85ml Freezing Point D2386 IP 16 62 to 44 C 25ml Aromatics FIA D1319 IP 156 16 to 22 vol 0 75ml Smoke Point D1322 IP 57 ISO 1322 20 to 25mm 20ml Kin Vis 20 C D445 IP 71 EN ISO 3104 2 to 8mm s 20ml Acid Number D3242 IP 354 lt 0 100mg KOH g 100ml Mercaptans D3227 IP 342 150 3012 0 0001 to 0 0100 m m __ 40ml SETA MIVM GAS OIL 500ML Test Name ASTM Method l Range Amount test Distillation at 15 D1298 IP 160 EN ISO 3675 0 83 to 0 854kg l Up to 200ml Distillation IBP D86 IP 123 EN ISO 3405 160 to 190 C 100ml Distillation 1096 D86 IP 123 EN ISO 3405 200 to 242 C 100ml Distillation 5096 D86 IP 123 EN ISO 3405 260 to 290 C 100ml Distillation 9096 D86 IP 123 EN ISO 3405 320 to 350 C 100ml Distillation 9596 D86 IP 123 EN ISO 3405 335 to 368 C 100ml Distillation FBP D86 IP 123 EN ISO 3405 350 to 385 C 100ml Distillation Residue D86 IP 123 EN ISO 3405 1 25 to 1 42 vol 100ml Distillation Loss D86 IP 123 EN ISO 3405 0 26 to 0 7 vol 100ml Flash Point D93 IP 34 EN ISO 2719 56 to 80 C 75ml Cloud Point D2500 D5771 IP 444 17 to 4 C Up to 38ml 05772 1 445 D5773 IP 446 IP 219 ISO 3015 EN 23015 CFPP D6371 IP 309 EN 1166 30 to 0 C 45ml
175. 9 12 18 27 38 61 90 155 253 434 700 17 78 C_ 13 C 0 F 1145 32353 8 6 F 179 400 12 5 C 9 5 F 100 00 C 212 00 F 1 2 1 5 1 9 2 3 2 6 3 8 5 6 77 12 17 20 26 32 37 59 87 90 122 149 241 413 667 17108 164 300 12 22 12 C 10 F 156 500 SAYBOLT VISCOSITY SUS SFS SFS 100 00 F 210 00F 12200 F 97 155 280 522 950 90 1693 131 180 137 11 5 C 11 C 11 3 F 6 67 C 10 4 F 12 2 F 20 F 9 533 151 200 137600 126 100 44 0 1932 564391 LF 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk Viscosity Standards amp Reference Materials Viscosity VISCOSITY STANDARDS SETAVIS VISCOSITY STANDARDS Setavis KAV Duplex Tubes should be individually verified or calibrated at the intended test temperature and nearest flow time using certified viscosity standards For calibration two standards are required for each tube to provide at least 50 difference in flow time as required by ASTM D446 VISCOMETER TUBES M0 C RANGE STANDARDS 100 RANGE STANDARDS First Standard Second Standard First Standard Second Standard Nominal Tube Seta Part No Nominal Viscosity Nominal Viscosity Seta Nominal Viscosity Constant mm2 s mm s Part No mm s Nominal Viscosity Seta Part No mm2 s Seta Part No 0 05 99784 0 2 9 99785 0 5 7 99786 0 3 9 99787 0 1 5 0 1 99831 0 75 99786 0 18 99787 0 75
176. 910 0 PORTABLE DIGITAL BAROMETER 4 8 17 19 22 23 28 29 145 99915 0 HANDHELD DIGITAL PRESSURE INDICATOR 145 99920 0 SETADIGIT CALIBRATED DIGITAL PRECISION THERMOMETER 129 99922 0 PRECISION DIGITAL THERMOMETER 22 23 83 130 99925 0 SETADIGIT CALIBRATED DIGITAL PRECISION THERMOMETER 129 99927 0 DIGITAL THERMOMETER WITH INTERCHANGEABLE PROBES 63 100 130 99928 0 SETATHERM 8 10 14 16 33 35 37 129 99940 0 DIGI PETRO THERMOMETER 128 99945 0 NON MERCURY LIQUID IN GLASS THERMOMETER 127 99960 0 DIGITAL PHOTO TACHOMETER 4 5 18 63 100 147 99965 0 PORTABLE FLOWMETER 148 99970 0 T90 FIRE RESISTANT STORAGE CABINET LARGE 157 99975 0 T90 FIRE RESISTANT STORAGE CABINET SMALL 157 Index Part Number SA1000 0 SA1000 2 SA1001 0 SA1002 0 SA1003 0 SA1004 0 SA1005 0 SA1006 0 SA1008 0 SA1010 0 SA1014 0 SA1016 0 SA1020 0 SA1022 0 SA1024 0 SA1026 0 SA1030 0 SA1035 0 SA1100 0 SA1200 0 SA2000 0 SA2200 0 SA2400 0 SA3000 2 SA4000 0 SA4000 001 SA4001 0 SA4002 0 SA4003 0 SA4004 0 SA4007 0 SA4008 0 SA4010 0 SA4011 0 SA5000 0 SA5001 0 SA5003 0 SA5006 0 SA5020 0 SA5021 0 SA5025 0 SefaAnaluftics AVCOUNT PARTICLE COUNTER AVCOUNT PARTICLE COUNTER BATTERY POWERED CALIBRATION FLUID FLIGHT CASE PC SOFTWARE BOTTLES 250ml AND CAPS pack of 30 CONTAINER SAMPLING KIT VERIFICATION FLUID HIGH PRESSURE ADAPTOR BOTTLE TUMBLER BOTTLE CARRIER 500ml ADJUSTABLE BOTTLE CARRIER IATA TUMBLER 5 litre SAMPLING KIT
177. 99789 0 99837 0 99833 0 99788 0 99790 0 99840 0 99788 0 99835 0 99791 0 99841 0 99835 0 99789 0 99841 0 99792 0 Nominal Viscosity mm s Seta Part No Seta Part No COLOUR REFERENCE STANDARDS REFERENCE STANDARDS High stability Certified to UKAS ISO 500ml bottle Suitable for routine calibration of instruments and verification of test results The highly colour stable standards are also suitable for instrument and laboratory correlation Each colour reference standard is packaged in a 500ml bottle and has a shelf life of 12 months 6 months for Pt Co standards YR CONFORMANCE CERTIFICATE 150 9001 OR wee CALIBRATION CERTIFICATE UKAS SEE TABLE ASTM COLOUR REFERENCE STANDARDS ASTM D1500 D6045 Certified Value nom Certification lt 0 5 UKAS to ISO 17025 UKAS to ISO 17025 UKAS to ISO 17025 UKAS to ISO 17025 Certification ISO 9001 ISO 9001 ISO 9001 ISO 9001 ISO 9001 ISO 9001 Certified Value nom Certification 10 UKAS to ISO 17025 0 UKAS to ISO 17025 12 UKAS to ISO 17025 25 UKAS to ISO 17025 Certification UKAS to ISO 17025 UKAS to ISO 17025 UKAS to ISO 17025 w www st Reference Materials amp Standards Flash Point 99878 3 CERTIFIED FLASH POINT MATERIALS SMALL SCALE CERTIFIED FLASH POINT MATERIAL ASTM 03278 03828 D7236 IP 523 IP 524 IP 534 ISO 3679 ISO 3680 BS 3900 Part A13 UN Class 3 Non viscous Flammable Liquids 74 C flash point nominal
178. 99833 0 13 03 99786 0 18 99832 0 29 99834 0 21 99789 0 36 0 5 99832 0 29 99787 0 54 99789 0 36 99837 0 57 99833 0 114 99788 0 99790 0 83 99840 0 99788 0 181 99835 0 324 99791 0 242 99841 0 406 99835 0 324 99789 0 99841 0 406 99792 0 628 MULTI TEST VERIFICATION MATERIALS VERIFICATION MATERIALS highly cost effective solution to laboratory verification requirements Verification to ASTM CEN ISO IP and equivalent test procedures Incorrect determination of a result can have far reaching financial and safety implications The growing use of automated instrumentation increases the possibility that incorrect results may go undetected and in addition the early indication of bias is a useful warning to minimise production giveaway Multi Test Verification Materials MTVM allow routine monitoring of instrument performance and are also particularly helpful in training personnel on new equipment and test methods We recommend the purchase of MTVM s with new instrumentation to assist with installation and commissioning Seta MTVMs are unique because unlike most other certified reference materials that are only suitable for validating a specific parameter value MTVM s enable a user to validate different tests and instrumentation using the same sample material MTVMs are blended by a major multi national refining company in conformance with ISO 9001 and ISO IEC EN 17025 ISO Guide 25 and EN 45001 and tested internationally by a
179. A FUEL OIL 500ML Test Name ASTM Method Range Amount test Density at 15 C D1298 IP 160 EN ISO 3675 0 94 to 0 994 kg l 200ml Pour Point D97 IP 15 D5985 D5950 14 to 7 C Up to 38ml D5949 D6749 D6892 EN ISO 3016 Kin Vis 50 C D445 IP 71 EN ISO 3104 150 to 1800mm s Up to 40ml Kin Vis 100 C D445 IP 71 EN ISO 3104 20 to 95mm2 s Up to 40ml Micro Carbon D4530 IP 398 150 10370 0 10 to 30 0 m m 2ml Flash Point D93 b IP 34 b 92 3 to 121 6 C 75ml EN ISO 2719 b SETA LUBRICATING OIL 500ML Test Name ASTM Method Range Amount test Kin Vis 40 D445 IP 71 EN ISO 3104 70 to 160 mm s Up to 40ml Kin Vis 100 D445 IP 71 EN ISO 3104 10 to 19 mm s Up to 40ml Viscosity Index D2270 IP 226 ISO 2909 139 to 180 Up to 80ml Pour Point D97 IP 15 D5985 D5950 49 1 to 33 C Up to 38ml D5949 06749 06892 EN ISO 3016 Hash Point D93 IP 34 EN ISO 2719 196 to 213 C 75ml SETA MTVM BITUMEN 250ML Test Name ASTM Method Range Amount test Softening Point IP 58 EN ISO 1427 37 to 54 C 7 5ml Needle Penetration IP 49 EN ISO 1426 41 to 200 Pen 130ml SETA BIO MTVM GAS OIL 500ML ULSD EN 590 Biofuel 5 FAME EN 14214 in Diesel A BIO FUEL TESTING Test Name ASTM Method Sample Result Amount test Distillation at 15 C D1298 IP 160 0 8404kg l Up to 200ml Distillation IBP D86 IP 123 173 6 C 100ml Distillation 10 D86 IP 123 204 7 C 100ml Distillation 50 D86 IP 123 260 7 C 100ml Distillatio
180. A GEL 1kg 14066 0 FLUORESCENT GEL 40g 14070 3 VIBRATOR UNIT ADSORPTION for one or two columns to assist packing of silica gel 14080 0 STANDARD ADSORPTION COLUMNS set of 2 for details see below OR 14090 0 PRECISION TRUE BORE COLUMNS set of 2 for details see below 14120 0 HYPODERMIC NEEDLE 102mm long x 18 gauge With Luer lock pack of 5 83710 0 HYPODERMIC SYRINGE 1ml capacity graduated to 0 01ml and fitted with Luer lock for needle pack of 10 Note Other items which may be required include Isopropyl alcohol Nitrogen gas bottle and regulator 45000 0 SETAPLUS EXTENDED 12 MONTH WARRANTY Power Voltage 99850 0 VERIFICATION MATERIAL ASTM D1319 IP 156 Kerosine for details see page 150 99854 0 VERIFICATION MATERIAL ASTM D1319 IP 156 Motor Gasoline Size HxWxD for details see page 151 Weight 14080 0 STANDARD ADSORPTION COLUMNS Two standard adsorption columns each column comprising 12 2 ball Seta Part No joint joint clip charger capillary with drawn tip and silicone tubing to 13730 005 join the charger and capillary 14080 001 All components available separately see table 14080 003 14090 003 14090 0 PRECISION TRUE BORE ADSORPTION COLUMNS Two precision True Bore adsorption columns each column comprising Seta Part No 12 2 ball joint joint clip combined charger separator analyser section 14080 003 tip and tip joint clip 14090
181. ALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE FSA TECHNICAL DATASHEETS AVAILABLE DC9 9 9 FOR SPECIFICATIONS ACCESSORIES amp CONSUMABLES SEE PAGE 14 BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE TECHNICAL DATASHEETS AVAILABLE 9 0 S v CALIBRATION CERTIFICATE WORKS OPTIONAL Flash Point Smoke Point amp Sustained Burning Small Scale Flash Point SETAFLASH SMALL SCALE FLASH POINT SPECIFICATIONS Temperature Range 10 to 130 C 50 to 266 F 10 to 130 C 50 to 266 F Ambient to 300 C Ambient to 300 C 0 to 300 C with 13870 0 0 to 300 C with 13870 0 Rapid Equilibrium and Ramp Rapid Equilibrium and Ramp Rapid Equilibrium and Ramp Rapid Equilibrium Sample Size 2ml for flash points up to 100 C 2ml for flash points up to 100 C 2ml for flash points up to 100 C 2ml for flash points up to 100 C 4ml for flash points above 100 C 4ml for flash points above 100 C 4ml for flash points above 100 C 4ml for flash points above 100 C Test Duration 1 minute below 100 C 2 minutes 1 minute below 100 C 2 minutes 1 minute below 100 C 2 minutes 1 minute below 100 C 2 minutes Rapid Equilibrium Mode above 100 C or user determined above 100 C or user determined above 100 C or user determined above 100 C 1 to 99 minutes 1 to 99 minutes 1 to 99 minutes Heating and Cooling System Peltier Cell Peltier Cell Cartridge heater
182. ALITY TESTER IQT M EN 15195 2005 E ASTM D6890 IP 498 Specifications EN 590 ASTM D975 D6751 D7467 BS 2869 Correlates with ASTM D613 Automated test procedure Precise results Repeatability of 0 92 Reproducibility 2 69 52 CN Optimise refinery blending Tighter control of cetane additives Minimize give away Small 100ml sample size Fast analysis lt 20 mins Durable tough instrument some instruments have 20 000 tests Fully approved and specification compliant Suitable for use with B100 The Ignition Quality Tester IQT V is a reliable affordable more precise and quiet alternative to a cetane engine It is a fully automated test instrument for deriving the cetane number for a wide range of middle distillate fuels including conventional and oil sands based diesels biodiesels refinery streams plus fuels using oxygenate and nitrate based cetane enhancers Significantly smaller and quieter than a traditional cetane engine the IQT M requires less infrastructure uses compressed gases that are readily available in cylinders throughout the world and is designed for an industrial laboratory type environment The IQT M automatically carries out all pre test and test procedures analyses the data and presents the results in under 20 minutes The combustion chamber injection system and fuel gas metering systems are mounted on a sturdy chassis attached to the top of a wheeled cabinet The cabinet also
183. ASHCHECK pack of 3 for details see page 156 VR EM 13220 2 Thermometers supplied separately 13230 3 Thermometers supplied separately Cup Type Temperature Range 220 240V 50 60Hz 220 240V 50 60Hz _ _ CONSUMABLES TAG Flash Point Testers Ramp Rate Bath fluid Voltage 2 Years 2000 Tests nM 13220 2 13230 3 o odo remo STURT un SILICONE RUBBER TUBE Ames 1 1 Flash Point Smoke Point amp Sustained Burning Pensky amp Abel Flash Point PENSKY MARTENS FLASH POINT 13661 3 SETA PENSKY MARTENS CLOSED CUP TESTER ASTM D93 E502 IP 34 IP 35 IP 404 obs EN 22719 ISO 2719 ISO 15267 BS 2000 Parts 35 amp 404 obs AASHTO T73 811 NF M07 019 JIS K2265 FTM 791 1102 Ambient to 370 C temperature range SUPPLIED WITH sample cup lid and shutter Variable ramp rate stand and instruction manual Two speed stirrer Forced air cooling facilit C g y ND BIO FUEL TESTING A Pensky Martens closed cup flash point tester with an electrically heated cup adjustable CALIBRATION amp VERIFICATION MATERIALS temperature ramp rate and two speed stirrer Suitable for use with mains gas or Seta 13667 0 1866156 Thermometer suppl pplied separately gas canister A compressed air supply can be SETAPLUS EXTENDED WARRANTY AVAILABLE attached to the rear of the instrument to allow rapid cooling in between tests ACCES
184. ATION MATERIAL Kerosine 152 99859 0 SINGLE TEST VERIFICATION MATERIAL Gas Oil 152 99860 0 SINGLE TEST VERIFICATION MATERIAL Fuel Oil 152 99862 0 SINGLE TEST VERIFICATION MATERIAL Fuel Oil 152 99863 0 SINGLE TEST VERIFICATION MATERIAL Lube Oil 152 99865 0 SINGLE TEST VERIFICATION MATERIAL Gasoline 152 99866 0 SINGLE TEST VERIFICATION MATERIAL Fuel Oil 152 99867 0 SINGLE TEST VERIFICATION MATERIAL Gas Oil 152 99868 0 SINGLE TEST VERIFICATION MATERIAL Gasoline 152 99869 0 SINGLE TEST VERIFICATION MATERIAL Gas Oil 152 99878 3 SMALL SCALE CERTIFIED FLASH POINT MATERIAL 8 10 14 15 156 99880 0 FLASHCHECK pack of 3 4 6 7 17 19 156 99882 0 CLEVELAND STANDARD 156 99883 0 CLEVELAND STANDARD 156 99884 0 CLEVELAND STANDARD 156 99890 0 FLOW CUP VERIFICATION OIL 47 99891 0 FLOW CUP VERIFICATION OIL 47 99892 0 FLOW CUP VERIFICATION OIL 47 99893 0 FLOW CUP VERIFICATION OIL 47 99894 0 FLOW CUP VERIFICATION OIL 47 99895 0 FLOW CUP VERIFICATION OIL 47 99896 0 FLOW CUP VERIFICATION OIL 47 99897 0 FLOW CUP VERIFICATION OIL 47 99898 0 SINGLE TEST VERIFICATION MATERIAL Kerosine 152 99900 0 SAFETY SPECS pack of 4 21 99902 0 SINGLE TEST VERIFICATION MATERIAL Gas Oil 153 99903 0 SINGLE TEST VERIFICATION MATERIAL Gas Oil 153 99904 0 SINGLE TEST VERIFICATION MATERIAL Gas Oil 153 99905 0 SIMDIS STVM Kerosine Jet Turbine Fuel 153 99906 0 SIMDIS STVM Gas Oil 153 99908 0 BIO MULTI TEST VERIFICATION MATERIAL Gas Oil 18 28 29 49 51 52 151 99
185. Aviation Turbine Fuel ASTM D3712 Analysis of Oil Soluble Petroleum Sulfonates by Liquid Chromatology IP 369 IP 143 Determination of Asphaltenes DIN 51 595 DIN 51 367 51 368 51 417 pt 1 Oil Content of Water Mixed Cooling Lubricants DIN 51 589 Testing of Water Separation Ability DIN 51814 Mineral Oil Content and Soap of Lubricating Greases Dialysis Method 44 0 1932 564391 F 44 0 1932 568363 sales stanhope seta co uk w www stanhope seta co uk 143 Calibration amp Verification Density amp Temperature CALIBRATION AND VERIFICATION The following precision instruments independently measure amd validate many of the critical parameters relevant to the test methods listed in this catalogue These products are suitable for Calibration to National Standards and are supplied with Certificates of Calibration HYDROMETERS Seta offer a large range of hydrometers suitable for use in test methods and for calibration purposes Please refer to Section 20 Temperature amp Fluid Density on pages 124 135 It is recommended that hydrometers used at ambient temperatures should be recalibrated within 2 years of purchase and thereafter at intervals of 7 to 10 years If a hydrometer is regularly used above ambient temperatures so that it is consistently heated and then cooled as frequently occurs in the testing of fuel oils it is wise precaution to recalibrate the hydrometer annually This will determine whether the thermal condit
186. Base Plate for 18480 0 Supports two 18480 0 wax containers ASTM D1321 IP 376 DIN 51 579 WATER BATHS 18200 5 SETA WATER BATH Wide range of applications 18 litre capacity Compact footprint A small footprint water bath with digital control and a temperature range from ambient 5 C to 100 C The control unit heater unit incorporates a stirrer and overtemperature and low level cutouts Control at near ambient temperatures Is obtained by using either the 18203 0 Cooling Unit with Coil or the 18204 0 Cooling Coil shown in Accessories The bath is manufactured from stainless steel and is equipped with a stainless steel pent roof lid SUPPLIED WITH perforated draining shelf to support sample containers mains lead and instruction manual SPECIFICATIONS Temperature Range Ambient 5 C to 100 C 0 C to 100 C with cooling 15650 0 WATER PURIFIER to minimise scale production Suitable for domestic water supply 60l hr max flow Comprises disposable cartridge with capacity for 960L soft water or 180L hard water Temperature Stability Capacity 18 litres 110 120V 50 60Hz 220 240V 50 60Hz 18203 0 COOLING UNIT WITH COIL chilled recirculating unit which extends the range of the bath to operate at sub ambient temperatures Voltage 110 120V 50 60Hz 220 240V 50 60Hz 18204 0 COOLING COIL uses a supply of cooling water to facilit
187. Bath REQUIRED Select from the table ITEMS REQUIRED FOR EACH TEST TEST SPECIMENS amp HOLDERS Select from the table ITEMS REQUIRED FOR EACH TEST and refer to page 79 11210 2 SETA STIRRER WITH AUXILIARY BLADE used for heavier than water fluids pack of 2 ALUMINIUM OXIDE CLOTH 150 grit FEPA 28 x 23cm pack of 50 ALUMINIUM OXIDE CLOTH 240 grit FEPA 28 x 23cm pack of 50 BAFFLED BEAKER with 2 baffles for NACE TM0172 2001 tests pack of 4 GRINDING AND POLISHING RIG polishes the specimen at the speed specified in the method SETA CHUCK BODY AND LOCK NUT grips test specimen during polishing BEAKER 25ml 30mm dia 50mm high flat bottom SYNTHETIC SEA WATER SOLUTION ASTM D665 procedure B 30ml pack of 10 for details see page 79 SYNTHETIC SEA WATER SOLUTION ASTM D665 procedure B 300ml for details see page 79 ANALYTICAL BALANCE for details see page 141 LABORATORY OVEN for details see page 137 BATH OIL technical white oil 20 litres for temperatures up to 80 C Note 2 required 11240 0 11250 0 11260 0 11275 0 11280 0 11325 0 11225 0 11227 0 99100 2 99200 2 94633 0 94635 0 BATH OIL technical white oil 20 litres for temperatures between 80 and 120 C Note 2 required 45001 0 SETAPLUS EXTENDED 12 MONTH WARRANTY THERMOMETERS ASTMS9C IP15C or ASTM9F IP15F or ASTM34C IP21C 11200 5 SPECIFICATIONS pp 110 120V 60Hz 220 240V 50 60Hz 1 5kW maxi
188. Block Condenser Melting Point Apparatus 97 120 123 107 106 106 106 106 93 86 56 Part Number 21400 001 21520 4 21530 4 21540 4 21550 4 21560 5 21600 4 21620 4 21690 4 21560 302 21560 303 21560 501 22100 0 22100 002 22100 003 22100 004 22101 4 15155 006 15155 201 15155 202 15155 204 15155 205 16155 303 22110 0 22121 0 22120 3 22120 007 22150 5 20470 501 21560 302 21560 303 22150 001 22150 003 22210 3 11400 601 11400 602 11400 603 11400 604 16155 303 16155 402 16155 406 22220 4 15155 006 15155 201 15155 202 15155 204 15155 205 16155 303 22300 2 22300 201 22300 202 22310 201 22310 2 22320 2 22300 202 22310 201 22400 0 22400 001 22400 002 22400 003 22400 005 22410 0 22400 002 22400 003 22400 005 22410 001 22422 6 22422 001 22422 601 22422 602 22422 603 22422 604 22422 605 22422 606 22422 607 22430 3 20470 501 21560 303 22422 001 22430 301 Graduated Test Tube pack of 10 Sampling Cylinder 50ml Sampling Cylinder 100ml Sampling Cylinder 200ml Sampling Cylinder 250ml Sampling Cylinder 500ml Sampling Cylinder 1 000m Sampling Cylinder 2 000m Sampling Cylinder 4 000m Nitrile Seal for 1 8 inch BSP pack of 5 Nitrile Seal for 1 4 inch BSP pack of 5 Right angled Valve Pressure Hydrometer Apparatus Gasket pack of 10 Pressure Cylinder p m m a Buffer pair Hydrometer Bath amp Cooler Fuse pack of
189. C obs IP 235 ISO 3993 NF M41 008 obs JIS K2249 e 1400kPa 200 psi max working pressure Operating temperature range 20 to 45 C Transparent cylinder pressure tested to 2800kPa 400psi Steel safety mesh For determining the density or specific gravity of light hydrocarbons including LP gases Comprises a polymethylmethacrylate pressure cylinder surrounded by a stainless steel mesh for maximum safety A vapour vent valve with tee piece for a pressure gauge is mounted on the top A buffer pad Is incorporated for the hydrometer and a mounting clip for a thermometer Inlet and outlet valves are mounted in the base and the instrument is connected to the LPG line via 1 4 BSP connections A range of hydrometers and thermometers are available as accessories SUPPLIED WITH instruction sheet PRESSURE CERTIFICATE WORKS SETAPLUS EXTENDED WARRANTY AVAILABLE 22101 4 with 22100 0 supplied separately 97300 0 97320 0 ACCESSORIES Schilling Effusiometer OPTIONAL 97310 0 SETA TRANSIT CASE lightweight with foam inserts to receive Effusiometer thermometer and spares SETA METAL STAND with carrying handle to support Effusiometer when in use THERMOMETERS IP39F or IP39C 97320 0 ACCESSORIES Pressure Hydrometer App REQUIRED Refer to the table of ITEMS REQUIRED FOR EACH TEST and select from the following options 22580 2 SETA PRESSURE GAUGE 0 to 2000 kPa 0 to
190. CIFICATIONS vane m ACCESSORIES Saybolt Universal Chromometer CALIBRATION VERIFICATION amp TRAINING SETA CERTIFIED COLOUR STANDARDS for details see page 114 15311 2 CONSUMABLES Saybolt Universal Chromometer 2 Years 2000 Tests 15311 202 O RING Viton pack of 5 15311 204 BULB 60W pack of 2 15311 206 GASKET for tube pack of 12 Colour Comparators Colour Standards amp Conformance Filters COMPARATORS 15250 4 SETA LOVIBOND COLOUR COMPARATOR ASTM D1500 IP 196 BS 2049 BS 5859 ISO 2049 791 102 NF T60 104 JIS K2580 High discrimination 2 disc system Three section field of view Consistent illumination For visual determination of the colour of oils and petroleum waxes Readings calibrated in accordance with ASTM D1500 The three section field of view optical system allows a sample and two reference standard colour filters to be viewed simultaneously allowing easy comparison of colour The colour filters are mounted in two discs one with full value standards and the other with intermediate value standards giving improved discrimination over single disc comparators The discs and sample are illuminated by a tungsten quartz halogen light source colour corrected to CIE standard illuminant C Replacement white inserts are available to ensure correct lighting levels are preserved SUPPLIED WITH two filter discs three sample containers power supply unit
191. COVER 64 GLASSWARE AIR RELEASE VALUE 104 ANILINE POINT METHODS 93 ASPHALTENES 93 CAPILLARY ADSORPTION COLUMNS 92 CENTRIFUGE TUBES 109 COKING BULBS 85 CFPP TUBES 52 CLOUD amp POUR POINT TEST JARS 51 DEAN amp STARK 31 DISTILLATION FLASKS 29 31 DISTILLATION RECEIVERS 29 31 EXISTENT GUM TEST BEAKER 87 FLAT GLASS TEST TUBE 76 77 118 FOAM TEST CYLINDERS 102 FREEZE POINT 53 HERSCHEL CYLINDERS 105 HYDROMETERS 132 133 INDUCTION PERIOD LINER 66 68 69 MCRT SAMPLE TUBES 84 OXIDATION KITS 71 72 ROBOT 64 SCHILLING 116 135 SILVER CORROSION KIT 7 SPECIAL PURPOSE 143 SULFUR LAMP 97 Subject Page MULTI TEST VERIFICATION MATERIAL MTVM 150 151 NON MERCURY THERMOMETER 127 NORTON STONE amp TUBE 102 OVEN LABORATORY 137 OXFLO CONTROLLER 72 OXIDATION BATH WITH OXFLO CONTROLLER 73 PRESSURE CYLINDER NORMA HOFFMAN 69 STABILITY CONSOLE BATH 66 VESSEL 64 OXIDATION amp OXIDATION STABILITY AUTOMATIC RECORDING amp CONTROL 65 67 AVIATION FUELS 66 BATHS 64 73 CATALYSTS 73 DISTILLATE FUEL OIL 73 FLOW CONTROL 72 GASOLINE 66 HYDROCARBON BASED INSULATING LIQUIDS 70 71 INDUCTION PERIOD METHOD 66 INHIBITED MINERAL INSULATING OIL 64 70 71 73 INHIBITED MINERAL OILS 64 70 71 73 INSULATING amp STEAM TURBINE OILS 64 Index General Subject Page QUARTER SCALE CONE 60 QUARTZ TIMER SIX CHANNEL 141 148 QUICK CONNECTS HANSEN 97 119 123 SCHRADER 123 RACK FOAM CYLINDER 102 ROBOT 64 RECEIVERS DISTILLATION 29 31 REDWOOD
192. D287 D1298 IP 160 API 2547 BS 4714 obs DIN 51 757 EN 3675 ISO 650 NF T60 101 JIS K2249 D 12356 GRAVITY ASTM E100 SERIES SHORT FORM 60 F ASTM D287 API GRAVITY HYDROMETER SELECTION CHART ASTM Ref E100 Long 1H 2H 3H 4H 5H Seta Part 12355 01 12355 02 12355 03 12355 04 12355 05 12355 06 12355 07 12355 08 12355 09 12355 10 Range 0106 51011 10 to 16 15 to 21 20 to 26 25 to 31 30 to 36 35 to 41 40 to 46 45 to 51 50 to 56 55 to 61 60 to 66 65 to 71 70 to 76 75 to 81 80 to 86 85 to 91 90 to 96 96 to 101 ASTM Ref E100 Short 21H 22H 23H Seta Part 12356 01 12356 02 12356 03 12356 04 12356 05 12356 06 12356 07 12356 08 12356 09 12356 10 12356 11 12356 12 12356 13 12356 14 12356 15 12356 16 12356 17 12356 18 12356 19 12356 20 SPECIFICATIONS ASTM Series E100 Long Form E100 Short Form Scale Sub Division 0 1 API 0 1 API CONFORMANCE OR CALIBRATION CERTIFICATES WORKS OR UKAS AVAILABLE SEE PAGE 131 FOR DETAILS API GRAVITY THERMO HYDROMETERS ASTM E100 12382 GRAVITY ASTM E100 SERIES THERMO HYDROMETERS 0 TO 150 F 12383 GRAVITY ASTM E100 SERIES THERMO HYDROMETERS 30 TO 180 F 12381 GRAVITY ASTM E100 SERIES THERMO HYDROMETERS 60 TO 220 F ASTM D287 API GRAVITY THERMO HYDROMETER SELECTION CHART Range API 51HL 52HL 53HL 54HL 55H
193. D892 and stoppers interconnection tubing and junctions mains leads and 14019 0 Tie SHRI Cate instruction manual 220 240V 50Hz Note Air supply Seta Air Pump 14019 0 and diffusers required 22750 2 DIGITAL STOPWATCH hand held 0 1s resolution for details see page 141 THERMOMETERS ASTM12C IP64C or ASTM12F IP64F 7 CALIBRATION amp VERIFICATION MATERIALS Mote LU 5 eet Other items which may be required include Dessicant Silica Gel Solvents OPTIONAL SETAPLUS EXTENDED WARRANTY AVAILABLE 14020 002 GRADUATED CYLINDER 1000ml borosilicate glass pack of 2 14020 006 CYLINDER FOOT to allow the graduated cylinder to stand upright on a bench top pack of 2 14026 0 TEMPERATURE PROBE AND INDICATOR for monitoring sample temperature 14029 0 RACK FOAM CYLINDER allows vessels to be held for purposes such as draining or cooling includes drip tray 14181 2 QUAD LOW TEMPERATURE BATH CONVERSION KIT to convert from 2 cylinders to 4 cylinders 14191 2 QUAD HIGH TEMPERATURE BATH CONVERSION KIT to convert from 2 cylinders to 4 cylinders 14021 0 Norton Stone V 15650 0 WATER PURIFIER to minimise scale production Suitable for domestic water supply 60l hr max flow Comprises disposable cartridge with capacity for 960 litres soft water or 180 litres hard water SPECIFICATIONS 99300 2 MINI LOW TEMPERATURE BATH CIRCULATOR to provide chilled water if Polycarbonate local supply exceeds 18 C for details see page 139 45
194. E CARBIDE PAPER 240 grit pack of 50 11470 0 SILICONE CARBIDE PAPER 100 grit pack of 50 11480 0 SILICONE CARBIDE GRAINS 150 mesh 5 packs of 500g 11490 0 GLASS SUPPORT CRADLE pack of 3 11500 0 COPPER CORROSION TEST VESSEL 11510 0 SILVER CORROSION CONVERSION KIT 11514 0 TONGS 11515 0 SILVER CORROSION TEST KIT GASOLINE 11520 0 TEST TUBE EJECTOR SPRING 11530 0 MULTI STRIP VICE 11550 0 COPPER TEST STRIP pack of 30 11570 0 FLAT GLASS TEST TUBE pack of 10 11580 0 ASTM IP COPPER STRIP CORROSION STANDARD 11590 0 TEST TUBE pack of 10 11600 0 PETROLATUM DROP POINT APPARATUS 11602 0 BS894 THERMOMETER SLEEVE amp CASE 11604 0 BS894 THERMOMETER SLEEVE amp CASE 11610 0 PHARMACOPOEIA DROP POINT APPARATUS 11619 00 08 U TUBE VISCOMETERS 11625 01 09 SUSPENDED LEVEL VISCOMETERS 11628 01 09 SUSPENDED LEVEL VISCOMETERS SHORTENED FORM 11634 01 12 CANNON FENSKE ROUTINE VISCOMETERS 11637 01 11 U TUBE REVERSE FLOW VISCOMETERS 11641 01 12 CANNON FENSKE OPAQUE VISCOMETERS 11643 01 16 UBBELOHDE VISCOMETERS 11663 01 10 ZEITFUCHS CROSS ARM VISCOMETERS 11675 01 11 CANNON MANNING VACUUM CAPILLARY VISCOMETERS 11676 01 07 ASPHALT INSTITUTE VACUUM CAPILLARY VISCOMETERS 11677 01 05 MODIFIED KOPPERS VACUUM VISCOMETERS 11700 0 LUBRICATING GREASE DROP POINT APPARATUS 11730 2 GREASE DROP POINT OVEN 11740 0 GREASE CUP AND SUPPORT ASSEMBLY 11750 0 THERMOMETER DEPTH GAUGE 11760 0 CUP PLUG GAUGE 11770 0 GO NOT GO CUP GAUGE Page 4 8 83 1
195. E types in AVTUR Analysis time 20 minutes 50ml sample volume Measuring range down to 10 mg kg No hydrocarbon cleaning solvents required Laboratory and field instrument Suitable for untrained operators 110 240V operation amp 12V option USB connection to PC Laptop Footprint size 36 x 37 x 45 cm Windows based XP Vista Windows 7 compliant software SA5000 0 The analyser measures the FAME levels in AVTUR 10 to 400 mg kg or higher with dilution to check they are within acceptable industry limits Using a unique sample preparation module patent pending the sample is pumped at a regulated flow rate through a proprietary disposable cartridge that is interfaced with the instrument The sample components are spectrally analysed by the FTIR and a result is displayed within typically 20 minutes The results are displayed as a simple go no go for field use user definable limits and mg kg volume The system is self cleaning so no solvents are required After each test the cartridge is simply and easily replaced and the instrument is immediately ready for the next sample ACCESSORIES Fame in Jet Instrument SA5001 0 FIJI STARTER KIT comprising 10 cartridges 10 nylon filters 280 low lint wipes 11 50ml beakers verification fluid 30 mg kg and verification fluid TECHNICAL DATASHEETS AVAILABLE 100 mg kg SA5003 0 LOW LINT WIPES pack of 280 SA5006 0 FIJI LAPTOP Measurement range 10 400 mg kg FAME i
196. EN 590 Diesel Fuel Specifications for Aromatics SA2400 0 EVOCHrOM JET FUEL SYSTEM ASTM D6379 IP 436 Measures Aromatics in Aviation and Jet fuels Chromatography assured with optimised column technology meeting the latest ASTM D6379 and IP 436 Method requirements Fully compatible to meet and measure Aromatics as referenced in DEF STAN 91 91 Jet Fuel Specifications for Aromatics 92 Particulates Residues amp Composition ADSORPTION 14060 0 SETA TWIN COLUMN ADSORPTION APPARATUS ASTM D1319 IP 156 BS 2000 Part 156 ISO 3837 FTM 791 3703 NF M07 024 JIS K2536 of saturates olefins and aromatics in petroleum fractions Analyses 2 samples simultaneously Accepts standard adsorption or precision True Bore columns Integral UV illumination A wall mounted system that comprises a control box measuring scales with slide markers mounting clips for two columns and a 365mm UV light mounted vertically to optimise fluorescence when viewing boundaries and saturates zones Separate pressure gauges and valves provide individual pressure control to each column SUPPLIED WITH mounting bracket and instruction manual Note Columns Seta 14080 0 or 14090 0 required CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE ACCESSORIES Twin Column Adsorption Apparatus 14050 0 CLEANING NEEDLE stainless steel 155cm Ig 19 SWG 45 tip with connector for 6 5mm 1 4 inch hose 14065 0 SILIC
197. ER 35 37 KV 2 VISCOMETER BATH 38 KV 4 VISCOMETER BATH 38 KV 6 VISCOMETER BATH 37 KV 8 VISCOMETER BATH 36 LABORATORY OVEN 137 LABORATORY REFRIGERATOR 140 LEAD IN GASOLINE 94 LIGHT WEIGHT PLUNGER 61 LIQUID RECOVERY SYSTEM 15 LIQUID SAMPLERS 120 LOAD VERIFICATION KIT 98 149 LOW TEMPERATURE BATH CIRCULATOR 139 VISCOSITY BATH 38 LPG CORROSION PRESSURE VESSEL 77 118 MANOMETER U TUBE 25 DIGITAL 145 MCLEOD GAUGE 146 MELTING POINT 56 MICRO CARBON RESIDUE TESTER 84 MICROSCOPE 98 MINI LOW TEMPERATURE BATH CIRCULATOR 139 MIRROR amp CLAMP 59 MOTT DIFFUSER amp TUBE 102 MULTI FILTRATION TESTER 83 MULTIFLASH ABEL CLOSED CUP MODULE 2 5 BASE UNIT 2 CLEVELAND OPEN CUP MODULE 2 6 PENSKY MARTENS CLOSED CUP MODULE 2 4 SMALL SCALE CLOSED CUP MODULE 2 8 TAG CLOSED CUP MODULE 27 MULTI LEVEL SAMPLERS 120 MULTI STRIP VICE 16 77 118 INSULATING OILS 10 71 LUBRICATING OILS 10 71 MINERAL INSULATING amp TURBINE OILS 10 71 NON AQUEOUS FIRE RESISTANT FLUIDS 64 POTENTIAL RESIDUE METHOD 66 ROTATING BOMB ROBOT 64 TOST BATH 72 TURBINE OILS 10 71 OX COR BATH 68 74 OXYGEN CHARGING amp PURGING KIT 64 67 PRESSURE GAUGE 69 PARTICLE COUNTER AVCOUNT 80 81 PASTE ULLAGE amp WATER FINDING 122 PENETRATION BITUMEN 59 61 CALIBRATION KIT 59 149 CONES 60 CONTACT SENSING OF SAMPLE 58 59 GREASE 60 KITS 60 NEEDLES 60 PENETROMETERS 58 59 PETROLATUM 58 61 SAMPLE CONTAINERS 61 UNIVERSAL 58 59 WATER BATH 61 WAX 58 61 PENSKY
198. F Long 60 F Long 60 F Long 60 F Long 60 F Long 60 F Long 60 F Long 60 F Sp Gravity Sp Gravity Sp Gravity Sp Gravity Sp Gravity Sp Gravity Sp Gravity Sp Gravity Sp Gravity Sp Gravity 12352 01 12352 02 12352 03 12352 04 12352 05 12352 06 12352 07 Short 60 F Short 60 F Short 60 F Short 60 F Short 60 F Short 60 F Short 60 F 0 650 to 0 700 0 700 to 0 750 0 750 to 0 800 0 800 to 0 850 0 850 to 0 900 0 900 to 0 950 0 950 to 1 000 Sp Gravity Sp Gravity Sp Gravity Sp Gravity Sp Gravity Sp Gravity Sp Gravity THERMOMETER SELECTION TABLE Thermometers required when carrying out Relative Density Specific Gravity or API Gravity measurements with ASTM hydrometers IP Ref IP64F IP64C IP39C Temp Range 5 to 215 F 20 to 102 C 1 to 38 C ASTM D287 ASTM D1298 CONFORMANCE CERTIFICATE WORKS Quote the ASTM or IP part number i e ASTM12C CALIBRATION CERTIFICATE UKAS Add the suffix Z to the IP or ASTM part number i e ASTM12CZ Temperature amp Fluid Density Hydrometers RELATIVE DENSITY SPECIFIC GRAVITY HYDROMETERS ASTM E100 BS 718 150 649 12351 12352 12320 12321 RELATIVE DENSITY ASTM E100 SERIES LONG FORM 60 60 F RELATIVE DENSITY ASTM E100 SERIES SHORT FORM 60 60 F ASTM 01298 IP 160 API 2547 BS 4714 obs DIN 51 757 EN 3675 ISO 650 NF T60 101 RELATIVE DENSITY BS 718
199. F GLASSWARE 72 16914 0 SAMPLE FILTERING KIT 72 16915 0 FILTRATION amp ACCESSORY KIT 72 Index Product Number Part Number Page Part Number Page 16916 0 FILTRATION KIT 72 19890 0 TORQUE WRENCH 98 16919 0 PREFORMED COPPER STEEL CATALYST COIL pack of 6 71 73 19895 0 ASTM TEST BALLS pack of 500 98 16920 0 STEEL CATALYST WIRE 3m pack of 6 71 72 73 19900 2 SETA SHELL 4 BALL EP LUBRICANT TESTER WITH AUTOLOAD SYSTEM 98 16921 0 PREFORMED COPPER STEEL CATALYST COIL pack of 6 72 73 19910 0 CHART RECORDER 98 16930 0 COPPER CATALYST WIRE pack of 6 64 71 72 73 19920 0 TRANSFORMER 98 16931 0 PREFORMED COPPER CATALYST COIL pack of 6 64 73 19930 0 LOAD VERIFICATION KIT 98 149 16932 0 CATALYST P 64 73 19940 0 WEAR LOADING KIT 98 16950 0 ACCESSORY PACK 72 20290 4 AIR PUMP 97 104 136 16960 0 BATH WITH OXFLO CONTROLLER 73 20410 0 SULFUR LAMP METHOD UNIT 97 16980 0 THERMOMETER SPECIAL for ASTM D943 72 20460 2 SYNTHETIC AIR UNIT 97 16990 005 ICE BATH 117 20470 5 SINGLE VALVE SAMPLING CYLINDER 100ml 97 119 123 16990 2 FREEZING POINT APPARATUS 53 20490 0 COMPLETE SET OF GLASSWARE 97 16992 0 MOISTURE PROOF COLLAR A 53 20510 4 SINGLE VALVE SAMPLING CYLINDER 50ml 119 123 16993 0 MOISTURE PROOF COLLAR B 53 20520 0 COTTON WICK 500g ball pack of 2 97 17000 2 UNIVERSAL PENETROMETER 59 20540 3 REGULATING VALVE 97 17120 0 MIRROR AND CLAMP 59 20550 0 FLASK pack of 2 97 17150 0 PENETROMETER CALIBRATION KIT 59 149 20560 0 BURNER p
200. ION STABILITY 64 ULTRASONIC CLEANING 142 VAPOUR PRESSURE 24 VISCOSITY 32 39 44 46 WATER 61 138 BEAKER COVER AND TEST SPECIMEN HOLDER 79 BEAKER EXTRACTION TOOL 87 BENCH VISCOMETER STAND 36 37 39 BITUMEN ACCESSORY KIT 35 BLOCK HEATER 109 BLOTTER TEST 96 BUBBLE FLOWMETER 71 BULK STORAGE SAMPLING 120 121 BURNERS COAL GAS 29 85 103 LPG 29 85 103 NATURAL GAS 29 85 103 BURNING QUALITY KEROSINE 21 BURNING RATE TEST RIG 21 CALIBRATION PENETRATION 59 149 PRESSURE 25 146 REFERENCE MATERIALS 150 157 TEMPERATURE 124 127 VACUUM 146 VISCOSITY 40 42 VOLTAGE 115 WEIGHTS CERTIFIED 141 147 CANNON FENSKE VISCOMETERS 41 CANNON MANNING VISCOMETERS 42 CANS SAMPLING 121 CARBON RESIDUE TEST 84 85 CATALYSTS COPPER COIL 73 COPPER STEEL COIL 73 COPPER WIRE 73 IRON WIRE 73 OXIDATION 73 STEEL WIRE 73 CENTRIFUGE HEATED OIL TEST 108 109 CERTIFIED REFERENCE MATERIALS 150 153 CETANE IGNITION QUALITY TEST 110 111 CHARGING LEAD HIGH PRESSURE 97 119 123 LOW PRESSURE 67 68 123 CHAR VALUES 21 CHART RECORDER 98 CHILLED SAMPLING 26 118 CHROMOMETER 113 CIRCULATORS REFRIGERATED 139 CLEANING BATH ULTRASONIC 142 CLEVELAND FLASH POINT TESTERS 6 19 CLOUD AND POUR POINT 50 51 Subject Page CLOUD AND POUR POINT REFRIGERATOR 50 COBALT BROMIDE DRYNESS TEST 117 COKING BULB 85 COLD FILTER PLUGGING POINT CFPP CFPP APPARATUS 52 CFPP BATH 52 CFPP INSERT 52 COLORIMETERS 112 COLOUR amp PARTICLE RATING 82 COLOUR COMPARATOR 114 COL
201. IP Standard Cone Acetyl Solid Conical 102 5g 0 05g CONFORMANCE CERTIFICATE UKAS IP 50 only 1 000 0 SETA ASTM IP Optional Cone Hollow Conical 102 5g 0 05g 18050 0 SETA ASTM IP Optional Cone Brass Hollow Conical 102 5g 0 05g YW CONFORMANCE CERTIFICATE UKAS IP 50 only 17910 0 SETA Quarter Scale Cone Plastic Conical 3g 0 025g Use with Ultra Light Weight Plunger 17950 0 18060 0 SETA Half Scale Cone Brass Conical 22 50 0 025g Use with Light Weight Plunger 17380 0 TTE 18080 0 SETA Special Full Scale Cone Aluminium Conical 29 8g 0 05g PENETRATION NEEDLES ASTM D5 IP 49 BS 2000 Part 49 DIN 52 010 EN 1426 NF T66 004 unless otherwise stated 3 17mm 1 8 inch stem diameter SETA PART MASS NTO ESS 18520 0 SETA Standard Penetration Needle 2 50 Pack of 3 18510 0 SETA Standard Penetration Needle 2 5g CONFORMANCE CERTIFICATE UKAS IP 49 EN 1426 only 18512 0 SETA Standard Penetration Needle 2 5g Z CONFORMANCE CERTIFICATE UKAS ASTM 05 18510 0 18500 0 SETA Penetration Needle 2 5g For penetrations between 350 amp 500 pack of 3 18490 0 SETA Wax Penetration Needle 2 50 ASTM D1321 IP 376 DIN 51 579 LE SETA Wax Penetration Needle 2 5g CONFORMANCE CERTIFICATE UKAS Penetrometer Plungers Containers amp Water Bath Penetration MES ASTM D1403 IP 310 DIN 51 804 ISO 2137 SETA PART MASS NOTES 17380 0 SETA Light Weigh
202. Ice Bath Universal Penetrometer 59 Universal Penetrometer with Int Cont 58 Weight 50g Weight 100g Plunger 47 5g Socket Wrench 1 8 inch a f Setamatic Penetrometer 58 Weight 50g Weight 100g Plunger 47 5g Socket Wrench 1 8 inch a f Display PCB amp Keypad Sensor Board Assembly Sensor Drive Motor Drive Belt Counterbalance Spring Lamp pack of 3 Index opare Parts Part Number 17510 0 17510 001 17510 002 17800 001 17800 002 17790 0 17510 001 17510 002 17790 001 17790 002 17800 001 17800 002 18200 5 15155 006 15155 201 15155 202 15155 204 15155 205 16155 303 19400 3 14025 006 15153 004 19400 005 19400 006 19400 307 19400 308 19400 309 19420 0 19420 001 19610 4 19610 201 19610 202 19610 203 19610 204 19610 205 19610 206 19720 0 19720 001 19720 002 19722 0 19722 001 19722 002 19722 003 19722 004 19722 005 19722 006 19724 0 19724 001 19800 6 19800 002 19800 006 19800 007 19800 008 19800 010 19800 011 19800 014 19800 016 19800 017 19800 018 19800 019 19800 020 19800 021 19800 022 19800 023 19800 024 19800 025 19800 026 19800 034 19800 035 19800 036 19800 213 19800 227 19810 001 19820 0 19820 001 19900 2 19800 002 19800 006 19800 007 19800 008 Manual Grease Worker Brass Worker Pot Seal for Plunger pack of 5 Worker Plate Churn Plate Stanomatic Dual Grease Worker Brass Worker Pot Seal for Plunger pack of 5 Counte
203. KS THERMOMETERS 22 1 24 or ASTM61C IP63C WATER PURIFIER to minimise scale production SETA OXI FEED PRESSURE VESSEL a 15802 0 pressure vessel without a burst disc or discharge tube PRESSURE CERTIFICATE UKAS Note Other items which may be required include Oxygen Forced air drying oven Filter Funnel Hotplate 15650 0 15800 4 Oxidation Stability Oxidation SOLID BLOCK OXIDATION BATHS 16670 0 SETA OXI SOLID BLOCK BATH 4 WAY ASTM D525 D873 D2274 D4310 ASTM D7462 Oxidation Stability of Biodiesel Blends B100 and Blends of Biodiesel with Middle Distillate Petroleum Fuel Accelerated Method IP 40 IP 138 IP 157 IP 388 BS 2000 Parts 40 and 138 EN 7536 ISO 7536 1 e Dry block Over temperature cut out Small footprint The Seta Oxi Solid Block Bath is an aluminium block bath with digital temperature control that has been designed to accept up to four oxidation vessels for carrying out tests equivalent to the IP 40 test method Seta Oxidation Vessels 15802 0 are recommended for use with the Seta Oxi Block Baths Automatic pressure monitoring can be carried A out using a Seta Auto Oxidation Unit 15450 3 four channel or 15452 0 six BIO FUEL TESTING 16670 0 channel Alternatives are the Portable Cambridge Pressure Recorders 15611 2 or Seta Pressure Gauges 15600 0 SPECIFICATIONS ACCESSORIES Oxi Solid Block Bath
204. Kit Pack H 25 tests TBN Water Cell Gauge Biodiesel Test Kit 96 Water in Oil Reagent TAN Reagent Lead in Gasoline Test Kit 96 Reagent PackA B amp C Fuel Integrity Test Kit 95 Water in Oil Reagent Shell Water Capsules pack of 160 SSAFPAK Aviation Fuel Condition Test Kit 95 Shell Capsules pack of 160 Microbial Test Kit Consumables gloves tissues amp pad Beaker poly 25mm pack of 3 Oil Test Centrifuge 108 Bottom Inserts pack of 2 Controller Board LCD Module Rotary Knob with PCB for Control Panel Frequency Converter 230V Power Board Upper Front Panel complete Membrane Keyboard Motor 230V Housing Lid Upper Front Panel plastic part Lower Front Panel Fan 230V Micro Switch Imbalance Brake Resistor 230V rectangular Signalling Transmitter 141 148 Part Number 90000 318 90000 319 90000 320 90000 322 90000 323 90000 324 90000 325 90000 326 90000 327 90000 328 90000 329 90000 330 90000 331 90000 332 90000 333 90000 334 90000 335 90000 336 90000 337 90000 338 90200 4 15155 006 15155 201 15155 202 15155 204 15155 205 16155 303 91600 3 81002 201 91600 001 91600 002 91600 004 91600 006 91600 007 91600 008 91600 010 91600 012 91600 013 91600 014 91600 015 91600 017 91600 018 91600 019 91600 020 91600 021 91600 024 91600 026 91600 027 91600 301 91600 302 91600 303 91600 304 91615 001 91615 002 91615 003 91616 001 91616 002 91616 303 91635 00
205. L 56HL 57HL 58HL 59HL 60HL 0 to 150 F ASTM Ref Seta Part 12382 01 12382 02 12382 03 12382 04 12382 05 12382 06 12382 07 12382 08 12382 09 12382 10 12500 0 JAR Glass hydrometer reading jar with foot Supplied in packs of 5 30 to 180 F ASTM Ref Seta Part 51HM 52HM 53HM 54HM 55HM 56HM 57HM 58HM 59HM 60HM 12383 01 12383 02 12383 03 12383 04 12383 05 12383 06 12383 07 12383 08 12383 09 12383 10 60 to 220 F ASTM Ref Seta Part 51HH 52HH 53HH 54HH 55HH 56HH 57HH 58HH 59HH 60HH 12381 01 12381 02 12381 03 12381 04 12381 05 12381 06 12381 07 12381 08 12381 09 12381 10 SPECIFICATIONS ASTM Series ew ew w lw mnn Mmm SOAP 7 CONFORMANCE OR CALIBRATION CERTIFICATES WORKS OR UKAS AVAILABLE SEE PAGE 131 FOR DETAILS HYDROMETER JAR SPECIFICATIONS Temperature amp Fluid Density HYDROMETER CYLINDER STAND 12700 0 HYDROMETER CYLINDER STAND 3 PLACE ASTM 01298 IP 160 API 2547 A bench top stand supplied with three jacketed glass hydrometer reading jars and interconnecting manifolds Each jar has an integral PTFE drain valve Suitable for use with a low temperature circulator for density determinations at 15 C ACCESSORIES Hydrometer Cylinder Stand OPTIONAL 99300 2 MINI LOW TEMPERATURE BATH CIRCULATOR for details see page 139 Hydrometers and Density SPECIFICATIONS
206. L QUARTZ TIMER SPECIFICATIONS Timing 0 to 999 99 seconds Accuracy 0 0 03 sec between 10 and 60 C i 1 Start Stop Display Hold and Memory Power Supply 100 130V or 200 260V 50 60Hz switchable or 12 15V dc 83750 3 SPECIFICATIONS Displays time day month with Audible alarm Sui _ 22150 2 BALANCES 99100 2 ANALYTICAL BALANCE Automatic zero Selectable units Anti vibration filter Glass windshield with 3 access doors RS232 port Rugged electronic balance with wide angle LCD display The balance is equipped with filters to reduce vibration and a glass enclosure with sliding doors on three sides for ease of access Features include automatic zeroing selectable units and parts counting Programmable filters RS232 Interface SUPPLIED WITH mains lead and instruction manual CALIBRATION amp VERIFICATION MATERIALS SPECIFICATIONS Units of measurement g mg dwt ct oz Ib GN tl t m NN NN Wet ACCESSORIES Analytical Balance CALIBRATION VERIFICATION amp TRAINING 99110 0 CERTIFIED CALIBRATION WEIGHTS 11 metric weights for details see page 147 CERTIFIED CALIBRATION WEIGHTS 12 fractional weights for details see page 147 99120 0 99100 2 a General Laboratory Equipment Stirrers Cleaning amp Remote Paging Alarm STIRRERS Bn 24600 0 SETA UNIVERSAL STIRRER Variable speed 100
207. LE POWER ADAPTOR 14 33250 2 SETAFLASH SERIES 3 ACTIVE COOL CORROSION RESISTING 12 34000 0 MULTIFLASH BASE UNIT 2 34003 0 RS232 CABLE 4 8 34006 0 CRYOSTAT 20 C 5 7 8 139 34007 0 SHUTTER LUBE 5 7 34008 0 COOLING BOOST MODULE 4 8 34010 0 DRAUGHT SCREEN 4 8 34011 0 DRAUGHT SCREEN 7 34012 0 DRAUGHT SCREEN 5 6 34100 2 MULTIFLASH PENSKY MARTENS CLOSED CUP MODULE 4 34200 0 MULTIFLASH ABEL CLOSED CUP MODULE 5 34300 0 MULTIFLASH CLEVELAND OPEN CUP MODULE 6 34301 0 KIT 6 34400 0 TAG CLOSED CUP MODULE 7 34700 0 SMALL SCALE SETAFLASH CLOSED CUP MODULE 8 60005 002 DRY WELL PROBE CALIBRATOR 4 7 144 70200 0 SNOWPACK DRY ICE MAKER 53 140 70210 0 SNOWPACK MAJOR DRY ICE MAKER 53 140 70220 3 PORTABLE DRY ICE MAKER MODEL B 52 53 140 71001 0 SETA VENT 10 17 18 19 21 80000 0 ANALYSER 22 80003 0 TRANSFORMER 22 80004 0 VACUUM PUMP 22 23 136 80005 2 PRESSURE CALIBRATOR 22 25 67 146 80007 3 MCLEOD GAUGE 22 23 146 80008 0 DIGITAL VACUUM GAUGE 23 39 146 80009 0 SYRINGE 1ml c w LEURLOCK AND NEEDLE 22 81000 2 2 23 81002 2 PRINTER 4 8 23 83 88 81003 0 23 82000 0 SETAFLASH SERIES 8 HIGHTEMP CLOSED CUP TESTER 11 82100 0 SETAFLASH SERIES 8 ACTIVECOOL CLOSED CUP TESTER 10 82102 0 LID amp SHUTTER GAS 10 82150 0 SETAFLASH SERIES 8 ACTIVECOOL CORROSION RESISTING 10 83201 2 SAYBOLT REDWOOD VISCOMETER BATH 46 83250 0 VISCOSITY KIT 46 8325
208. LIBRATION CERTIFICATE WORKS All glass capillary viscometer tubes are supplied with a works calibration certificate CALIBRATION CERTIFICATE UKAS To order a glass capillary viscometer tube with a UKAS calibration certificate add the suffix Z to the part number i e 11677 02Z 11634 11641 11663 11643 44 0 1932 564391 Le 44 0 CALIBRATED CANNON FENSKE ROUTINE VISCOMETERS ASTM D445 D446 IP 71 ISO 3104 3105 With constant and certificate of calibration calibration data at 40 C with the constant quoted at 40 C and 100 C For transparent liquids requiring approximately 7ml of sample CALIBRATED CANNON FENSKE OPAQUE VISCOMETERS ASTM D445 D446 IP 71 ISO 3104 3105 With constant and certificate of calibration calibration data at 40 C with the constant quoted at 40 C and 100 C For transparent and opaque liquids requiring approximately 12ml of sample CALIBRATED ZEITFUCHS CROSS ARM VISCOMETERS ASTM D445 D446 IP 71 ISO 3104 3105 With constant and certificate of calibration For transparent and opaque liquids requiring 3ml of sample CALIBRATED UBBELOHDE VISCOMETERS ASTM D445 D446 IP 71 ISO 3104 3105 With constant and certificate of calibration For transparent liquids requiring 18ml of sample CALIBRATION CERTIFICATE WORKS All glass capillary viscometer tubes are supplied with a works calibration certificate CALIBRATION CERTIFICATE UKAS
209. Lift Start of Combustion ACCESSORIES IQT V 92002 0 SERVICE SPARES KIT comprising exhaust valve injector nozzle gaskets and 0 rings combustion chamber heater bleed valve for injection pump thermocouple set combustion pressure transducer 92007 3 START UP KIT comprising waste product and coolant overflow containers sample containers and filtering kit wash bottles and containers fume extraction system adaptor and trunking gas supply adaptors laser printer computer trolley and additional tools 92008 6 CALIBRATION KIT comprising nozzle opening pressure NOP calibrator mass calibration kit 92000 010 digital thermometer calibration materials 92010 2 POWER SUPPLY KIT with auto shut down system comprises uninterruptible power supply 3 hours isolating transformer combustion chamber over temperature cut out switch cables and connectors 92020 3 GAS REGULATOR KIT comprising a set of delivery panels cylinder supply end and point of use panels IQT end for the nitrogen and two air supplies Each panel includes all required regulators valves filters gauges and adaptors assembled and ready to mount TRIOTI INSTALLATION COMMISSIONING amp TRAINING IQT installation and commissioning local training of staff 92009 2 EXTRACTION FAN SYSTEM for positive fume extraction TRIQTM ADVANCED WORKSHOP amp MAINTENANCE TRAINING in depth training including advanced maintenance and repair work at Stanhope Seta in the UK TRIQTS SERVICE
210. M50 SERIES 20 C DENSITY BS 718 150 649 L50 SERIES 20 C DENSITY HYDROMETER SELECTION CHART M50SP 15 C L50SP 15 C M50 20 C Seta Part Seta Part Seta Part 12430 01 12431 01 12460 01 12430 02 12431 02 12460 02 12430 03 12431 03 12460 03 12430 04 12431 04 12460 04 12430 05 12431 05 12460 05 12430 06 12431 06 12460 06 12430 07 12431 07 12460 07 12430 08 12431 08 12460 08 12430 09 12431 09 12460 09 12430 10 12431 10 12460 10 L50 20 C Seta Part 12461 01 12461 02 12461 03 1246 1 04 12461 05 1246 1 06 12461 07 12461 08 12461 09 12461 10 Range g ml 0 600 to 0 650 0 650 to 0 700 0 700 to 0 750 0 750 to 0 800 0 800 to 0 850 0 850 to 0 900 0 900 to 0 950 0 950 to 1 000 1 000 to 1 050 1 050 to 1 100 JET TURBINE FUEL HYDROMETER ASTM D1298 D1655 DEF STAN 91 91 IP 160 A BS718 M50SP hydrometer specifically calibrated for a range of 0 775g ml to 0 825g ml Q 15 C for measuring the density of jet turbine fuels such as Jet A Jet A1 JP4 JP7 and J98 Vi CONFORMANCE CERTIFICATE WORKS SPECIFICATIONS 12430 12431 12460 12461 mem mmo Asume aM lt 7 CONFORMANCE OR CALIBRATION CERTIFICATES WORKS OR UKAS AVAILABLE SEE PAGE 131 FOR DETAILS SPECIFICATIONS A emer eM Hydrometers Temperature amp Fluid Density API GRAVITY HYDROMETERS ASTM E100 12355 GRAVITY ASTM E100 SERIES LONG FORM 60 F ASTM
211. MARTENS FLASH POINT TESTERS 4 18 PETROLEUM WAX MELTING POINT 56 PIPETTE DIGITAL 33 35 PLATINUM COBALT COLOUR REFERENCE STDS 114 155 PORCELAIN CRUCIBLE 85 POTENTIAL RESIDUE METHOD 66 POUR POINT 50 51 PRECISION ADSORPTION TRUE BORE COLUMNS 92 DIGITAL THERMOMETER 130 PRE COOLING 117 PRE HEATING amp FILTERING KIT 33 35 PRESSURE BLEEDING TEST CELL TYPE 106 CALIBRATOR DEAD WEIGHT 25 146 GAUGES REID VAPOUR PRESSURE 25 HYDROMETER APPARATUS 116 135 INDICATOR DIGITAL HAND HELD 145 RECORDER CAMBRIDGE PORTABLE 67 TRANSMITTING CAPILLARY 67 PRESSURE VESSELS COPPER CORROSION TEST 51 76 LPG COPPER CORROSION TEST 71 118 NORMA HOFFMAN 69 OXIDATION STABILITY 66 SAMPLING CYLINDERS 119 123 PRINTER 4 8 23 83 PROPANE DRYNESS TEST 117 PROTECTION COLLAR SAMPLING CYLINDERS 119 123 PROTECTIVE ARMOUR THERMOMETER CASE 128 PUMPS AIR PRESSURE amp VACUUM 136 SALT CONTENT OF CRUDE OIL ANALYSER 94 WATER CONTAMINATION 95 9b SAMPLE CHILLING amp COOLING 139 CONTAINERS 61 DISPENSER 15 REMOVAL 15 SPILLAGE 15 SAMPLE VESSELS COPPER CORROSION TEST VESSELS 51 76 DOUBLE VALVE CYLINDERS 119 123 NORMA HOFFMAN OXIDATION CYLINDERS 69 OXIDATION STABILITY VESSELS 66 68 69 REID PRESSURE CYLINDERS 24 SINGLE VALVE CYLINDERS 119 123 SAMPLERS BACON SAMPLING VESSELS 121 BOTTLE 122 CAGE PROTECTIVE 122 CANS 121 CYLINDERS 119 123 JET FUELS SSAFCON 82 LIQUID 120 MULTI LEVEL 120 SELF SEALING 120 UNIVERSAL 120 SAYBOLT COLOUR CO
212. N BATH ALSO AVAILABLE 16675 0 PLEASE CONTACT STANHOPE SETA FOR DETAILS NORMA HOFFMAN OXIDATION PRESSURE CYLINDER 16400 3 SETA OXIDATION PRESSURE CYLINDER NORMA HOFFMAN ASTM D942 D1402 obs IP 142 m B MEME u ACCESSORIES Oxidation Pressure Cylinder BS 2000 Part 142 Pressure tested to 1860kPa 270psi 16410 0 SETA DISH HOLDER stainless steel supports five glass dishes 16420 0 SETA GLASS DISH borosilicate pack of 10 Used to determine the resistance to oxidation of lubricating oil when stored statically in a sealed system with an oxygen atmosphere Comprises polished stainless steel cylinder with top closure and lead seal stem needle valve and quick connection coupling PRESSURE CERTIFICATE WORKS 16400 3 16450 0 OXYGEN PRESSURE GAUGE NH Oto 1380kPa 0 to 200psi Oxygen safe CALIBRATION CERTIFICATE WORKS An oxygen safe pressure gauge with a range of 0 to 1380kPa 0 to 200psi 150mm diameter suitable for use with 16400 3 Norma Hoffman oxidation cylinders CONSUMABLES Oxidation Pressure Cylinder 15640 001 NEOPRENE WASHER pack 0 50 En 16400 001 LEAD GASKET pack 0120 1 568363 E sales stanhope seta co uk w www stanhope seta co uk 69 Oxidation Oxidation Stability SOLID BLOCK OXIDATION BATHS 16600 2 ASTM 02440 D4636 04871 D5763 D5846 D6514 IP 48 IP 154 IP 280 IP 3
213. N MATERIALS SPECIFICATIONS Voltage 110 120V 50 60Hz 220 240V 50 60Hz Weight amp 10160 0 GLASSWARE FOR ANILINE POINT METHODS ASTM D611 Method A IP 2 Method A BS 2000 Part 2 BS 7391 obs ISO 2977 791 3601 NF M07 021 DEF STAN 05 50 01 Method 1 Comprises borosilicate glass test tube jacket iron wire stirrer and cork CALIBRATION amp VERIFICATION MATERIALS ACCESSORIES Thin Film Apparatus REQUIRED 10120 2 TRANSFORMER UNIT for 6 5V lamp Incorporates a brightness control for viewing sample Voltage 110 120V 50 60Hz 220 240V 50 60Hz Power 10kW Size HxWxD 11 x 16 x 23cm Weight 1 7kg SETA HOT 1000W electic heater with variable heat control for details see page 147 THERMOMETERS ASTM33C IP20C or ASTM 34C IP21C or ASTM35C IP59C Note Two thermometers of the same range are required OPTIONAL 99100 2 ANALYTICAL BALANCE for details see page 141 CALIBRATION VERIFICATION amp TRAINING 99850 0 VERIFICATION MATERIAL ASTM D611 Kerosine for details see page 150 25000 3 ACCESSORIES Glassware for Aniline Point Methods REQUIRED 24500 0 STEEL STAND Base 23 x 14cm column 76cm x 1 3cm dia stainless steel 24250 0 CLAMP 2 to 90mm capacity 24650 2 BOSSHEAD for fitting Seta 24520 0 to steel column THERMOMETERS ASTM33C IP20C or ASTM 34C IP21C or ASTM35C IP59C OPTIONAL 99100 2 ANALYTICAL BALANCE for details see pa
214. N MATERIALS rv SETA COMPACT CLOUD AND POUR POINT CRYOSTAT Three compartments Temperature range ambient to 34 C Three 2 litre compartments independantly temperature controlled between ambient and 34 C with a stability of 1 5 C SUPPLIED WITH 12 test jars each comprising graduated glassware thermometer cork insulating gasket and disc a compartment thermometer and instruction manual 2 BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS 91 Ej TECHNICAL DATASHEETS AVAILABLE 60 x 60 x 85cm 115kg 115kg 93531 7 Sample thermometers supplied separately 94100 3 Sample thermometers supplied separately Cloud amp Pour Point Cold Flow amp Freezing Point REFRIGERATED CLOUD amp POUR POINT BATHS ACCESSORIES C amp PP Cryostats CONSUMABLES C amp PP Cryostats REQUIRED 2 Years 2000 Tests THERMOMETERS 11000 002 GRADUATED JAR amp CORK pack of 10 High Cloud and Pour ASTM5C IP1C or ASTM5F IP1F 11000 003 INSULATING GASKET pack of 20 Low Cloud and Pour ASTM6C IP2C or ASTM6F IP2F 11000 004 INSULATING DISC pack of 20 Pre conditioning to ASTM D97 for fuel oils heavy lubricant base stock and products 93531 001 COMPARTMENT THERMOMETER containing residual fuel components ASTM 61C IP63C or ASTM 61F 93531 202 CORK JAR amp THERMOMETER WELL pack of 10 Note One thermometer is required for each test jar in simultaneous use in addition to the c
215. NFORMANCE FILTERS 113 114 COLOUR REFERENCE STANDARD 114 155 UNIVERSAL CHROMOMETER 113 VISCOMETER UNIVERSAL amp FUROL 46 SCHILLING EFFUSIOMETER 116 135 SEDIMENT BY EXTRACTION 86 SEPTUM SETAVAP 23 SETACLEAN TOTAL SEDIMENT TESTER 86 SETAFLASH CERTIFIED FLASH POINT MATERIAL 15 156 SERIES 3 ACTIVE COOL 12 SERIES 3 CLOSED CUP TESTER 13 SERIES 3 OPEN CUP TESTER 16 SERIES 3 PLUS CLOSED CUP RAMP 13 SERIES 8 ACTIVECOOL CLOSED CUP TESTER 10 SERIES 8 CLOSED CUP TESTER 10 11 SETAFOAM DUAL TWIN FOAM TEST BATHS 102 SETAFUGE HAZARD REDUCTION SYSTEM 109 SETA HOT 137 SETALERT RADIO PAGING SYSTEM 142 TRANSMITTER 142 SETA LOVIBOND AUTOMATIC COLORIMETER 112 COLOUR COMPARATOR 114 HIGH PRECISION COLORIMETER 112 SETAMATIC CONTROLLED HEATER 1KW 29 PENETROMETER 58 SETA ORBIS DIGISTILL THERMOMETER amp DATA PROCESSOR 30 PAM DISTILLATION UNIT 30 SETARAMP CONTROLLER 19 SETA SHELL 4 BALL LUBRICANT TESTER 98 99 SETASTILL DISTILLATION UNIT 29 Index General Subject Page SETATIME SIX CHANNEL QUARTZ TIMER 141 148 SETAVAP 2 23 SETAVAP ANALYSER 22 SETA VENT 19 SETAVIS DOUBLE 6 KINEMATIC AUTO VISCOMETER 32 DOUBLE 6 KINEMATIC VISCOMETER 34 KAV AUTO DUPLEX TUBE 33 49 154 SHEAR STABILITY HEAD 98 SILICA GEL 82 92 SILICONE CARBIDE ABRASIVES 64 68 72 76 77 118 SILICONE BATH OIL 138 SILVER CORROSION BY AVIATION FUELS 68 74 BATH CONVERSION KIT 76 77 GLASSWARE 76 77 TEST KIT GASOLINE 76 77
216. NG EO Zx E E E LZ L K I 3 J Lu Uri U 1 wu E WES A A E Z21810 AZ Temperature Range Ambient 5 to 150 C Temperature Stability 0 1 C No of Oxidation Test Stations B Bath Fluid Water to 99 C or Oil Bath Capacity 35 litres Heater Power 1500W Supply Voltage 41x45 x 33cm 10kg Size HxWxD Weight LOI Seta Part No D525 D873 IP 40 IP 138 15450 3 15600 0 15611 2 15802 0 15803 0 15805 0 15810 0 22750 2 199100 2 99200 2 ASTM22C e ASTMET C e Items marked A are options for pressure monitoring eoe00 lA Gib cdatell Glatvateaadlat P DECCIIDE MAN 7 Nie PRESOURE MUN 3 OPTIONS ITEMS REQUIRED Seta Part No AUTOMATIC PRESSURE MONITORING 15450 3 Seta Auto Oxidation Control Unit 1 1 1 ENHANCED ANALOGUE PRESSURE MONITORING 15611 2 Portable Cambridge Pressure Recorder 1 1 2 ANALOGUE PRESSURE MONITORING 15600 0 Seta Pressure Gauge 1 2 3 1 Vessel 2 Vessels 3 Vessels mi 15550 2 Glassware and pressure vessels supplied separately SSORIES Oxi Cor Bath 15455 0 TRANSDUCER complete with lead Note 1 required per oxidation
217. NS 79 STRIP COPPER 76 77 118 STRIPS SILVER 76 77 TFOUT 64 THERMO HYDROMETERS 116 131 133 135 THERMOMETER ASTM 124 125 CALIBRATION 128 130 DEPTH GAUGE 55 56 Subject DIAL TYPE DIGITAL DIGITAL amp PROBE DIGITAL amp THERMOCOUPLES DIGITAL amp INTERCHANGEABLE PROBES HOLDER IP NON MERCURY PROTECTIVE CASES SETAVIS BATH TANK SAMPLING CASE VISCOSITY THERMOSTIR UNIT THIN FILM ANILINE POINT THIMBLE EXTRACTION APPARATUS TIMER SIX CHANNEL TONGS TORQUE WRENCH TOST TOTAL ACIDITY TOTAL BASE NUMBER TBN TOTAL SEDIMENT TESTER TRANSFORMER OILS DIELECTRIC STRENGTH TRI GAUGE VISCOSITY COMPARATOR TROLLEY CENTRIFUGE TURBINE OIL OXIDATION TEST TWIN COLUMN ASORPTION UBBELOHDE VISCOMETERS ULLAGE CHAMBERS PASTE amp RULE ULTRA LIGHT WEIGHT PLUNGER ULTRASONIC CLEANING BATH VACUUM GAUGE DIGITAL VACUUM PUMPS VALVE FREEZE PROPANE DRYNESS VAPOUR PRESSURE TESTERS VAPOUR LIQUID RATIO VERIFICATION KIT FOAM VERIFICATION MATERIAL MULTI TEST SINGLE TEST VERTICAL TEST SPECIMEN VIBRATOR UNIT ADSORPTION VISCOMETER BATH BROOKFIELD TUBE CLEANER TUBE KINEMATIC BITUMEN TUBE SETAVIS KAV AUTO DUPLEX KINEMATIC TAR VISCOMETERS CANNON FENSKE CANNON MANNING COMPARATOR TRI GAUGE COMPARATOR VISGAUGE HOLDER MODIFIED KOPPERS PAINTS amp VARNISHES REDWOOD NO 1 SAYBOLT SETAVIS SUSPENDED LEVEL UBBELOHDE U TUBE U TUBE REVERSE FLOW VACUUM CAPILLARY ZEITFUCHS VISCOSITY ADHESIVES ASPHALTS amp BITUMEN
218. NT SPECIFICATIONS ain CALIBRATION CERTIFICATE WORKS FOUR BALL LOAD CALIBRATION EQUIPMENT SETA LOAD VERIFICATION KIT Suitable for use with Four Ball Lubricant Tester 19900 2 Direct measurement of load in test cell A load cell fits in place of the plunger assembly test cell in Seta Four Ball Lubricant Testers and displays the actual load applied on an LCD display SUPPLIED WITH load cell meter interconnection leads mains lead and instruction manual SETA PENETROMETER CALIBRATION KIT Verifies the calibration depth of movement of Penetrometers Comprises set of precision ground dimension gauges Supplied in protective box CALIBRATION CERTIFICATE UKAS CALIBRATION CERTIFICATE WORKS PENETRATION Reference Materials amp Standards MTvM MULTI TEST VERIFICATION MATERIALS 99850 0 99851 0 Ahighly cost effective solution to laboratory verification requirements Verification to ASTM CEN ISO IP and equivalent test procedures Cross checks instrument performance using real product Assistance for operator training Incorrect determination of a result can have far reaching financial and safety implications The growing use of automated instrumentation increases the possibility that incorrect results may go undetected and in addition the early indication of bias is a useful warning to minimise production giveaway Multi Test Verification Materials MTVM
219. OD 45cm long 121 18510 0 STANDARD PENETRATION NEEDLE 60 21770 0 RELIEF VALVE HIGH PRESSURE 97 119 123 18512 0 STANDARD PENETRATION NEEDLE 60 21780 0 RELIEF VALVE LOW PRESSURE 123 18520 0 STANDARD PENETRATION NEEDLE 60 21790 0 QUICK CONNECTION COUPLING HIGH PRESSURE 97 119 123 18530 0 SAMPLE CONTAINER BITUMEN 61 21800 0 QUICK CONNECTION COUPLING HIGH PRESSURE 97 119 123 18535 0 SAMPLE CONTAINER BITUMEN 61 21810 0 QUICK CONNECTION COUPLING LOW PRESSURE 123 18540 0 SAMPLE CONTAINER 49 61 21820 0 QUICK CONNECTION COUPLING LOW PRESSURE 123 18550 0 TRANSFER DISH pack of 2 61 97 21830 0 ADAPTOR pack of 2 119 123 18560 0 4 WAY MICRO PENETRATION CUP 61 21832 0 ADAPTOR pack of 2 119 123 18570 0 COVER 61 21835 0 ADAPTOR pack of 2 119 123 18580 0 ASTM 05 IP 49 STARTER KIT 59 21840 0 CONNECTOR PIPE 119 123 19400 3 ROLL STABILITY TESTER 63 100 21850 0 CONNECTOR PIPE 119 123 19401 0 THERMOMETER AND COLLAR ASSEMBLY 63 100 22090 0 COOLING UNIT 26 118 19420 0 CYLINDER 63 100 22100 0 PRESSURE HYDROMETER APPARATUS 116 135 19430 0 ROLLER 63 100 22101 4 HYDROMETER BATH AND COOLER 116 135 19610 4 WATER WASHOUT TESTER 100 22110 0 DRYNESS TESTER 117 19620 0 TEST BALL BEARINGS pack of 5 100 22120 35 DEW POINT APPARATUS 117 19720 0 FILTRATION KIT 82 22121 0 PRESSURE GAUGE 117 19722 0 SSAFLAB FILTRATION KIT 82 22122 0 PRESSURE GAUGE 117 19724 0 FILTRATION KIT 82 22123 0 PRESSURE GAUGE 117 19725 0 VACUUM P
220. ORIES Self Sealing Samplers Snatch cord opening OPTIONAL Reseals when container is full MULTI LEVEL SELF SEALING SAMPLERS Valve Throat Seta Part Capacity Diameter Diameter Length Weight Sample Vessel Cage Material 14840 0 500ml 2 3cm 10 2cm 39cm 1 7kg Bottle amp Lid Brass 14841 0 500m 2 3cm 10 2cm 39cm 1 7kg Bottle amp Lid Stainless steel 14842 0 1 litre 2 1cm 14cm 42cm 2 2kg Winchester Brass 14843 0 1 litre 2 1cm 14cm 42cm 2 2kg Winchester Stainless steel 14844 0 1 litre 2 1cm 7 38 2 2kg Can Stainless steel 14842 0 Winder Sampling Cans amp Bottles Tank Sampling amp Gauging aa CCOVCLO U f f f f 14866 2 WINDER 30 metre wire cable SPECIFICATIONS Ferrule at 1 5 and 10m intervals Tested at 20kg load Anti spark design Size LxWxDia 28 x 14 x 20cm dia reel Weight g A winder suitable for use with Seta Liquid Samplers for safe and clean sampling The geared drum carries 30 metres of 2mm dia dip wire and is fitted with a braking locking device The dip wire terminates in a latching hook for secure attachment to a sampler A small ferrule is attached to the dip wire at 1 metre intervals with a large ferrule every 5 metres and two large ferrules every 10 metres A grounding cable and clip provide electrical continuity between the sampler and electrical earth The winder is equipped with a
221. OUR CONFORMANCE FILTERS ASTM 114 COLOUR RATING BOOKLET ASTM 82 COLOUR REFERENCE STANDARDS ASTM 114 155 GARDNER 114 155 PLATINUM COBALT 114 155 SAYBOLT 114 155 CONDENSER UNIT 29 CONDITION MONITORING 95 96 CONDUCTIVITY 94 115 CONES PENETRATION 60 CONRADSON CARBON RESIDUE TEST 85 COOLANT MODULE 14 COOLING APPARATUS 56 BLOCK 14 UNIT 26 118 UNIT WITH COIL 61 COPPER CORROSION BATH 15 CATALYST WIRE 73 COPPER SILVER BATH 74 STANDARDS 76 77 118 TEST STRIP 76 TEST VESSEL 51 76 COPPER SILVER CORROSION BATH 74 CORK STOPPERS 109 CORROSION TEST BATH 77 118 COTTON WICK 97 CRANKCASE OILS FOAMING 102 CRYOSTAT 139 CUTTER FOR BLOCK GREASES 62 D86 DISTILLATION KIT 28 30 DEAN amp STARK WATER CONTENT 31 DEMULSIFICATION 103 DENSITY 116 132 133 135 DENSITY BALANCE 104 DENSITY MEASUREMENT KIT PORTABLE 134 DERIVED CETANE NUMBER 110 11 DESSICATOR 20 82 84 137 DEW POINT 117 DIAL THERMOMETER 47 62 DIELECTIC OIL TESTER 115 DIGI CORDER 64 65 DIP TAPE amp FRAME 122 DIP WEIGHTS 122 DISH HOLDER 69 DISTILLATE FUEL OIL OXIDATION STABILITY 73 DISTILLATION AUTOMATIC 30 BITUMEN 31 CUT BACK BITUMEN 31 DEAN amp STARK 31 FLASK HEATER 31 FLASK SUPPORT BOARD 29 FLASKS 29 31 MANUAL SETASTILL 28 29 ORBIS 30 PETROLEUM PRODUCTS 28 29 RECEIVERS 29 31 DRAUGHT SCREEN 4 5 6 7 8 14 16 DROP POINT OF GREASE 55 DRY ICE MAKERS 53 140 DRY WELL PROBE CALIBRATOR 4 7 144 DRYING TOWER 102 DRYING TOWER amp STOPPER 31 DRYNESS TE
222. P 195 EN 3405 BS 2000 Parts 123 191 amp 195 BS 658 BS 7392 ISO 198 FTM 791 1001 NF M07 002 obs JIS K2254 Suitable for gas or electrical heating Toughened glass window Front opening door Ready drilled for optional electric heater A distillation unit designed for gas or electric heating The levelling platform for glass ceramic flask support boards is ready drilled to receive the optional electric heater Fitted with a toughened glass observation window CALIBRATION amp VERIFICATION MATERIALS SETA CONDENSER UNIT Straight condenser Complements 11800 0 Distillation Unit A condenser tank fitted with a straight condenser for use with 11800 0 Seta Distillation Unit D86 DISTILLATION EQUIPMENT 11800 0 with 11850 0 installed 11810 0 and Accessories Size HxWxD 47 x 20 x 20cm Distillation Unit 83 x 45 x 19cm Condenser Unit Weight 6 1kg Distillation Unit 5kg Condenser Unit EM ORIES Seta Distillation amp Condenser Units PEN 11850 0 _ SETAMATIC CONTROLLED HEATER 1kW internally mounting with on off switch and temperature controller Voltage 110 120V 50 60Hz 220 240V 50 60Hz OR 11805 0 GAS CONTROL VALVE to regulate gas supply to burner AND ONE OF THE FOLLOWIING 10720 0 SETA BURNER for coal gas 10740 0 SETA BURNER fo
223. PPLIED WITH mains lead and instructions PRESSURE CERTIFICATE WORKS SPECIFICATIONS Temperature Range Ambient 5 to 220 C Internal Capacity 53 litres Power 1 4KW Voltage 110 120V 50 60Hz 220 240V 50 60Hz Size HxWxD 37 x 37 x 32cm internal 57 x 42 x 44cm external T Weight 35kg CALIBRATION CERTIFICATE WORKS SOFTWARE SUPPLIED SPECIFICATIONS Power 1000W Voltage 110 120V 50 60Hz 220 240V 50 60Hz Fi Size HxWxD 23x 15 x 15cm Weight 2 7kg SPECIFICATIONS Tank Capacity Pressure Relief Valve 7 12 litres 5 25 useable 0 14 to 40kpa 2 to 5 8psi Power 825W Voltage 110 120V 50 60Hz 220 240V 50 60Hz Size HxWxD 28 x 22 x 40cm Weight 5 2kg ACCESSORIES Steam Generator 15650 0 OPTIONAL z WATER PURIFIER to reduce lime scale 60l x hr maximum flow disposable cartridge 99200 2 25000 3 16130 3 General Laboratory Equipment Heating STIRRED LIQUID BATHS 15870 4 CIRCULATING WATER BATH Temperature range ambient to 12
224. PPLIED WITH two flow control units digital temperature controller mains leads and instruction manual Note Flowmeters glassware and catalysts must be ordered separately BIO FUEL TESTING SETAPLUS EXTENDED WARRANTY AVAILABLE 9 9 16630 0 SETA HIGHTEMP BATH 61125 METHOD C Supplied with flowmeters Similar to 16600 2 but supplied with flowmeters for tests to IEC 61125C 16635 0 SETA HIGHTEMP BATH 12 WAY 61125 METHOD Supplied with flowmeters Similar to 16620 2 but supplied with flowmeters for tests to IEC 61125C IP 280 IP 307 ISO DIS 7624 06 61125 uin 122750 0 e e e GLASSWARE 16720 0 16771 0 e 16840 0 16850 0 16860 0 FLOWMETERS 16601 2 e e e 16602 2 16603 2 16608 0 e 16660 0 e 16730 0 e THERMOMETERS 16610 0 IP22C e ASTM9C 15 40 IP80C 41 1 81 41 81 CATALYSTS 16780 0 e 16790 0 e e e 16791 0 16919 0 16920 0 16930 0 16890 0 Seta Part No 44 0 1932 564391 F 44 0 1932 568363 E sales stanhope seta co uk w www stanhope seta co uk IP 335 EN 61125B Oxidation Stability Oxidation SOLID BLOCK OXIDATION BATHS ACCESSORIES Hightemp Baths Select from the table ITEMS REQUIRED FOR EACH TEST 16720 0 GLASSWARE 27 x 210mm test cell assembly pack of 6 Note 2
225. PPLIED WITH two pressure transducers connection cable for a pc adaptor and software Note An IBM compatible personal computer not supplied is required SPECIFICATIONS CONSUMABLES AutoRoBOT Pressure Monitor E J SOFTWARE INCLUDED 2 Years 2000 Tests 15205 201 LINK LEAD ASSEMBLY SETA DIGI CORDER ASTM D2112 D2272 D4742 IP 229 Pressure range 0 to 1380kPa 200psi Selectable recording interval Switchable units kPa psi bar Memory Digital display RS232 port 15230 2 The Digi Corder is a digital recording manometer that can be screwed directly into the top of a 15210 5 R bot Oxidation Pressure Vessel The manometer can be programmed with the required pressure drop limit as specified in the method of test and the time interval between measurements 10 minutes after the pressure drop has been reached ie end of test the manometer will switch off automatically When turned on again the manometer will display the results of the last test The display shows the current pressure pressure drop units of pressure measurement and elapsed time The pressure readings at each time interval are automatically stored to the internal memory The data and resultant pressure time diagram can be downloaded via the RS232 port to a personal computer using the supplied software i SPECIFICATIONS The instrument is housed in a moisture proof case and is powered by a Em ms
226. PRESSURE CERTIFICATE WORKS b Corrosion amp Rust Rust RUST PREVENTION TEST PREVENTION TEST 11200 5 SETA RUST PREVENTION TEST BATH ASTM D665 D3603 D5534 IP 135 BS 2000 Part 135 FTM 791 4011 ISO 7120 NF T60 151 JIS 2510 NACE TM0172 2001 Ambient 5 C to 120 C temperature range 7 test stations Constant speed sample stirrers Quick release stirrers Digital temperature controller Bath viewing window and door Indicates the ability of steam turbine oils to prevent rusting of ferrous components should water become mixed with the oil Also used to test the corrosive properties of cargoes in petroleum product pipelines The 31 litre capacity oil bath has a temperature range of ambient 5 C to 120 C and is controlled by a digital thermostir unit to within 0 1 65 C The top panel of the bath accepts up to seven test beakers Each beaker is stirred at 1000 50 rev min by a quick release paddle stirrer The test specimen mounted in a holder acrylic for normal oils PTFE for synthetic fluids is immersed in the test fluid in the beaker and supported by the beaker cover A hinged front panel allows visual check to be made of sample mixing while the beakers are immersed in the bath SUPPLIED WITH seven standard stirrers and beakers mains lead and instruction manual SETAPLUS EXTENDED WARRANTY AVAILABLE OW TECHNICAL DATASHEETS AVAILABLE ACCESSORIES Rust Prevention Test
227. Point setup C02 DRY ICE MAKERS SNOWPACK DRY ICE MAKER SNOWPACK MAJOR DRY ICE MAKER PORTABLE DRY ICE MAKER MODEL B Rapid production of consistently sized blocks pellets Connects directly to liquid CO syphon type dip tube cylinders Dry ice liquid mixtures can produce temperatures down to 78 C The latent heat of vaporization of dry ice is 572 kJ kg 246 BTU per Ib Seta dry ice makers are a Safe efficient and convenient method of producing pellets and blocks in a range of sizes 70220 3 SUPPLIED WITH pressure hose and gauge Hardening amp Softening Softening Point 21000 SERIES RING AND BALL TEST UNITS SERIES RING AND BALL TEST UNITS The 21000 Series provides simple equipment to determine the softening point of a sample using the ring and ball method A steel ball is placed upon a disc of sample contained within a metal ring The assembly is 24500 0 heated in a bath and the temperature taken when the sample softens enough to allow the ball to fall through the ring CALIBRATION amp VERIFICATION MATERIALS 21001 2 RING AND BALL TEST UNIT 24600 0 amp 24640 0 z ASTM D36 IP 58 EN 1427 BS 76 o BS 2000 Part 58 BS 6043 Part 1 IS0 5940 NF T66 008 obs STPTC Pt 3 holder li Rectangular base plate 21002 2 RING AND BALL TEST UNIT 21
228. Pour Point D97 IP 15 D5950 D5949 D6749 D6892 D5985 33 to 6 C Up to 38ml EN ISO 3016 Kin Vis 40 C D445 IP 71 EN ISO 3104 2 3 to 3 5mm s Up tp 40ml Lubricity HFRR D6079 IP 450 ISO 12156 1 271 to 512 2ml Water Karl Fischer D1744 IP 438 EN IS0 12937 23 4 to 63 9mg kg 5ml LF 44 0 1932 568363 LE sales stanhope seta co uk www stanhope seta co uk MIVM Reference Materials amp Standards 99854 0 99852 0 99853 0 99856 0 99908 0 SETA MIVM MOTOR GASOLINE 500ML MULTI TEST VERIFICATION MATERIALS Test Name ASTM Method Range Amount test Motor Octane No D2700 150 5163 83 to 90 MON Research Octane No D2699 ISO 5164 95 to 101 RON Density at 15 C D1298 IP 160 EN 150 3675 0 721 to 0 763kg l Up to 200ml Distillation IBP D86 IP 123 EN ISO 3405 28 to 39 C 100ml Distillation 70 C D86 IP 123 EN ISO 3405 15 to 36 vol 100ml Distillation 100 C D86 IP 123 EN ISO 3405 36 to 58 ovol 100ml Distillation 150 C D86 IP 123 EN ISO 3405 75 to 93 ovol 100ml Distillation FBP D86 IP 123 EN ISO 3405 175 to 205 C 100m Aromatics FIA D1319 IP 156 19 to 42 vol 0 75ml Olefins FIA D1319 IP 156 1 5 to 15 vol 0 75ml Saturates FIA D1319 IP 156 42 to 72 vol 0 75ml Vapour Pressure D5191 IP 394 EN 13016 1 50 to 87kPa 3ml SET
229. Quick fit coaxial gas jet electric hot wire user selectable Electric hot wire pilot light for gas jet Temperature Probe Class A Platinum Resistance Thermometer C or F lonisation Ring Gas Supply gas jet ignitor Laboratory gas 3kPa 0 44psi maximum pressure Air Supply forced air cooling Dry compressed air 670kPa 100psi maximum pressure Voltage 110 120V or 220 240V 50 60Hz switchable Size HxWxD 34 x 45 x 42cm Weight Multi Method Flash Point 34300 0 mounted on a 34000 0 Base Unit with a 34012 0 Draught Screen fitted i CALIBRATION amp VERIFICATION MATERIALS SETALERT COMPATIBLE i TECHNICAL DATASHEETS AVAILABLE ACCESSORIES Cleveland Open Cup Module 00100 0 SETALERT REMOTE PAGING SYSTEM 23680 0 SPIRIT LEVEL 34003 0 5232 CABLE for connecting instrument to PC 34008 0 COOLING BOOST MODULE 34012 0 DRAUGHT SCREEN recommended for gas tests 34301 0 HUSSAMI KIT 81002 2 PRINTER 60005 002 DRY WELL PROBE CALIBRATOR for details see page 144 99880 0 FLASHCHECK secondary verification material for details see page 156 99910 0 PORTABLE DIGITAL BAROMETER 750 to 1500 mbar absolute for details see page 145 CONSUMABLES Cleveland Open Cup Module l le 34100 004 0 16 2 241300 001
230. R CONDENSER pack of 10 86 16160 2 SSAFCON SAMPLER 82 16165 2 MOUNTING TRAY 82 16170 0 MONITOR CASE pack of 48 82 16180 0 FILTER pack of 100 82 16190 0 MONITOR REFILL pack of 50 82 16200 0 COLOUR RATING BOOKLET ASTM 82 16210 0 COLOUR AND PARTICLE RATING CHART 82 16220 0 TWEEZERS pack of 2 82 16230 0 FILTER FILE 82 16400 3 OXIDATION PRESSURE CYLINDER NORMA HOFFMAN 69 16410 0 DISH HOLDER 69 16420 0 GLASS DISH pack of 10 69 16440 0 PRESSURE GAUGE 117 16450 0 OXYGEN PRESSURE GAUGE NH 69 16500 0 DEMULSIFICATION APPARATUS 103 16600 2 HIGHTEMP BATH UNIVERSAL OXIDATION 70 16601 2 FLOWMETER set of 6 70 71 16602 2 FLOWMETER set of 6 10 71 16603 2 FLOWMETER set of 6 10 71 16608 0 FLOWMETER set of 6 10 71 16610 0 DIGITAL THERMOMETER 71 16620 2 HIGHTEMP BATH 12 WAY 71 16630 0 HIGHTEMP BATH 71 16635 0 HIGHTEMP BATH 12 WAY 71 16640 0 TOST BATH 72 16645 0 TOST BATH 6 WAY 72 16660 0 BUBBLE FLOWMETER 71 16670 0 OXI SOLID BLOCK BATH 4 WAY 69 16675 0 OXI SOLID BLOCK BATH 6 WAY 69 16720 0 GLASSWARE pack of 6 71 16730 0 BUBBLE FLOWMETER 71 16771 0 GLASSWARE pack of 6 71 16780 0 IRON CATALYST WIRE 15m 71 73 16790 0 COPPER CATALYST WIRE 15m 71 73 16791 0 PREFORMED COPPER CATALYST COIL pack of 6 71 73 16840 0 GLASSWARE pack of 6 71 16850 0 GLASSWARE pack of 6 71 16860 0 GLASSWARE pack of 6 71 16890 0 5 METAL SPECIMEN SET 71 16900 5 OXIDATION BATH WITH OXFLO CONTROLLER 73 16905 2 OXFLO CONTROLLER 72 16910 0 SET O
231. R POINT P50 WATER CONTENT P108 FLASHPOINT P12 Rapid determination of Flexible compact Heated centrifuge with Rapid and portable cetane number refrigeration for cold tests optional hazard flashpoint testing reduction system T Seta MTVM Seta Shell 4 Ball KV 6 Bath GUM CONTENT P87 VISCOSITY P37 REFERENCE MATERIAL P150 TRIBOLOGY P98 Compact 5 place solid Compact high quality Traceable validation to Determines the friction and block bath with integral bath for all Kinematic ASTM CEN ISO IP and wear properties of oil and superheater measurements equivalent test procedures greases 44 0 1932 564391 LF 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk III Index Method page D 4 ua 58 60 ASTMD36 c DJS sss 2 7 17 ASTM DJ s 143 086 28 30 143 150 151 ASTM 087 96 088 48 ASTMD91 s 108 DJ 26 19 ASTM DY s 2 4 18 150 151 0935 3 ASTM D96 obs ss 108 ASTM DI uu 20 51 190 151 ASTMDI30 s 68 70 74 ASTM DIJE s 112 113 ASTMDI87 2 0189 85 ASTM 0216 obs sss 28 29 ASTMD217 s 58 60 62 DZA 31 D27 ua 133 ASTM D828 2225 DIJ ss 87 D402 sss 31 ASTM DMS 32 34 36 38 150 151 ASTM DME ss 32 38 36 38 ASTM D447 ob ss 28 29 ASTM 473 ss 86 DAZ ss 84 0524 85 ASTM 0525 sss 66 68
232. RATION amp VERIFICATION MATERIALS ACCESSORIES Grease Drop Point Oven REQUIRED 11740 0 SETA GREASE CUP AND SUPPORT ASSEMBLY comprises borosilicate glass test tube sample cup and support 1 5mm metal rod thermometer clamp with bushings and support rings Note Up to six assemblies can be used at a time in the Seta 11730 2 oven 11750 0 SETA THERMOMETER DEPTH GAUGE THERMOMETERS ASTM3F Note 1 required for each grease and 1 required for the 11730 2 oven CALIBRATION VERIFICATION amp TRAINING 11760 0 SETA CUP PLUG GAUGE to check dimensions of Grease Cup are to specification SETA GO NOT GO CUP GAUGE to check dimensions of cup orifice are to specification 11770 0 11730 2 CONSUMABLES Grease Drop Point Oven 2 Years 2000 Tests 11730 002 LAMP 130V pack of 5 11730 204 THERMOCOUPLE pack of 10 11740 001 TEST TUBE amp ROD pack of 10 PECIFICATIONS Power Supply 110 120V 50 60Hz 220 240V 50 60Hz Powe OW DEM C CcC C C 21400 0 MELTING POINT APPARATUS ASTM 087 IP 55 BS 4695 ISO 3841 FTM 791 1402 NF T60 114 JIS K2253 Cooling curve of petroleum waxes As a sample of molten petroleum wax cools the falling temperature will stabilise while the wax solidifies This is the melting point determined by the cooling curve Comprises a test tube marked with a filling line mounted in an air bath contained within a water bath assembly ACCE
233. RTL EH ASU ea 22620 2 SETA REDWOOD NO 1 VISCOMETER For ASTM E102 ASTM77F or ASTM78F or ASTM79F or ASTM80F or ASTM81F or ASTM108F or ASTM109F IP 70 obs For IP 170 IP8F or IP8C or IP9F or IP9C or IP10F or IP10C For BS 434 BS110C 110 23210 2 SETA TAR VISCOMETER Note ASTM 088 covers Saybolt Universal and Saybolt Furol viscosities of petroleum IP 72 BS 2000 Part 72 STPTC RT2 and RT3 products in the temperature range 21 to 99 C d d ASTM E102 covers Saybolt Furol viscosity in the temperature range 121 to 232 C NF T66 005 hope seta co uk w www stanhope seta co uk SETA BS ISO FLOW CUPS ASTM D5125 EN 535 ISO 2431 DIN 53 224 NF 30 070 obs Viscosity range from 8 to 2000mm s cSt Aluminium body with stainless steel jet Use for break thread flow measurement Note Cup 23611 0 is not in the current BS ISO series but is offered for use with high viscosity samples SETA B FLOW CUPS SETA FORD CUPS ASTM D1200 Kinematic viscosity range from 20 to 360 mm s cSt Brass construction SETA AFNOR FLOW CUPS T NFT 30 014 Kinematic viscosity range from 5 to 5100 centipoise Brass construction SETA ZAHN FLOW CUPS ASTM 0816 obs D1084 obs D4212 Dynamic viscosity range from 20 to 1200 centipoise Use for break thread flow measurement Kinematic viscosity range from 0 to 5 000 mm2 s cSt Brass construction Note This type of cup has been in popular use for many years but does
234. SCOMETER TUBES CAPILLARY KINEMATIC VISCOMETER TUBES VACUUM CAPILLARY VISCOMETERS FOR ASPHALTS 11675 CALIBRATED CANNON MANNING VACUUM CANNON MANNING VACUUM VISCOMETERS CAPILLARY VISCOMETERS _ 12102 11675 02 ASTM D2171 IP 222 0 11675 03 11675 04 11675 05 11675 06 11675 07 11675 08 11675 09 11675 10 11675 11 11677 CALIBRATED MODIFIED KOPPERS VACUUM V 9 C 0 M ETE RS w Range mm s No 180 to 3 200 11677 02 ASTM 021 11 IP 222 600 to 12 800 11677 03 2 400 to 52 000 11677 04 8 600 to 200 000 11677 05 For the viscometers above exact calibration factors must be determined with viscosity standards 11676 CALIBRATED ASPHALT INSTITUTE VACUUM ASPHALT INSTITUTE VACUUM VISCOMETERS CAPILLARY VISCOMETERS 07 as 50 11676 02 ASTM D2171 IP 222 100 11676 03 200 11676 04 400R 11676 06 800R 11676 07 Special design for roofing asphalts having additional marks at 5 and 10mm above timing mark Using these marks the maximum viscosity range Is increased from that using the bulb B calibration factor CALIBRATION CERTIFICATE WORKS All glass capillary viscometer tubes are supplied with a works calibration certificate CALIBRATION CERTIFICATE UKAS To order a glass capillary viscometer tube with a UKAS calibration certificate add the suffix 2 to the part number i e 11677 02Z VISGAGE POCKET COMPARATORS 22950 2 Determine In Service condition of lubrication oils Quic
235. SILVER CORROSION BATHS amp SILVER CORROSION BATHS 11300 0 SETA COPPER CORROSION BATH Ambient 5 to 100 C temperature range Copper and Silver corrosion tests 2 stations Small footprint The 11300 0 is an ultra compact water filled bath with a maximum temperature of 100 C and two test stations The bath is protected against low water level SUPPLIED WITH 2 lids mains lead and instruction manual A BIO FUEL TESTING 11305 0 SETA HIGH TEMP COPPER CORROSION BATH Ambient 5 to 150 C temperature range 2 stations m ie ccu a W The 11305 0 is a high temperature version of the 11300 0 Seta Copper I Corrosion Bath The oil filled bath has a maximum temperature of 150 C and is protected against over temperature and low fluid level SUPPLIED WITH 2 lids mains lead and instruction manual f BIO FUEL TESTING 11300 0 with Accessories Supplied separately 11308 0 SETA COPPER CORROSION SOLID BLOCK BATH Dry heating for up to 4 test samples A precision processor controlled block heater bath with 4 test wells designed to take Copper Corrosion test tubes as specified in ASTM D130 IP 154 The external temperature probe allows control of either Rapid heat up time the sample or the bath block and a separate test well is provided for e Ambient to 150 C calibration checks The bath has an integral timer and audible alarm
236. SINGLE TEST VERIFICATION MATERIAL STVM 152 153 SIMAIR LOW TEMPERATURE BATH 44 SIMAIR TEST CELL ASSEMBLY 45 SMALL SCALE SETAFLASH CLOSED CUP TESTERS 9 16 SMOKE POINT 20 SOFTENING POINT 54 SOIL PENETRATION LIQUID LIMIT 58 SOLID SAMPLE DISPENSER 15 SPECIAL FULL SCALE PENETRATION CONE 60 SPECIFIC GRAVITY 132 SPECIMEN SET METAL 7 SPILLAGE RECOVERY 15 SPIRIT LEVEL 36 37 39 SSAFCON SAMPLER 82 SSAFPAK AVIATION FUEL CONDITION TEST KIT 95 STANOMATIC DUAL GREASE WORKER 62 STEAM CALIBRATION KIT 87 149 GENERATOR 86 87 137 TURBINE OIL OXIDATION STABILITY 64 TURBINE OIL RUST PREVENTING PROPERTIES 78 STIRRERS ELECTRICAL 138 RECIPROCATING 53 THERMOSTATIC 138 UNIVERSAL 54 55 142 STOPWATCH DIGITAL 141 148 STORAGE CABINETS FIRE RESISTANT 157 STORAGE STABILITY 68 74 SULFUR LAMP METHOD 97 SUSTAINED BURNING OF LIQUIDS SETAFLASH 16 SYNTHETIC AIR UNIT 97 TACHOMETER PHOTO DIGITAL 147 TAG FLASH POINT TESTER 7 17 TANK SAMPLING CAN TYPE 121 DIP TAPE 122 MULTI LEVEL SAMPLERS 120 THERMOMETER CASE 122 UNIVERSAL SAMPLERS 120 WINDERS 121 TAPES DIP 122 TAR VISCOMETER 46 TARS DISTILLATION 31 TEMPERATURE CALIBRATOR DRY WELL 144 CONTROLLERS 128 130 INDICATOR DIGITAL 128 130 PROBE amp INDICATOR 102 TEST BALLS ASTM 98 BEARINGS 100 KIT FOR AVIATION FUEL CONDITION 95 KIT FOR BIODIESEL 96 KIT FOR FUEL INTEGRITY 95 KIT FOR LEAD IN GASOLINE 96 KIT FOR LUBRICATING OILS 96 SPECIMEN CONTAINER WAX 61 SPECIMEN HOLDER PTFE 79 SPECIME
237. SK HEATER suitable for up to three 500ml flasks requires multiples of 21200 0 and other accessories for details see page 31 OR FLASK HEATER suitable for up to six 500ml flasks requires multiples of 21200 0 and other accessories for details see page 31 24530 4 24540 4 ACCESSORIES Continued REQUIRED 99310 0 EVAPORATION BATH Temp range Tank capacity Voltage ambient to 100 C 6 litres 110 120V 50 60Hz 220 240V 50 60Hz 1 5kW 28 x 33 x 21cm 10kg SETA STEEL STAND for use with 24410 4 heater only Power Size HxWxD Weight 24500 0 24520 0 CLAMP 24650 2 BOSSHEAD for fitting clamp to stand Note Other items which may be required include Filter paper Forceps Toluene and Heptane OPTIONAL 22750 2 DIGITAL STOPWATCH 0 1s resolution for details see page 141 24403 0 FLASK 150ml capacity 24404 0 FLASK 250ml capacity 99100 2 ANALYTICAL BALANCE for details see page 141 99200 2 LABORATORY OVEN for details see page 137 ANILINE POINT 10000 0 10000 0 25000 3 supplied separately THIN FILM APPARATUS ASTM D611 Method B IP 2 Method B BS 2000 Part 2 BS 7391 obs ISO 2977 FTM 791 3601 NF M07 021 JIS K2256 The Thin Film Apparatus is designed to determine the Aniline Point in samples that are too dark to be determined using ASTM D611 Method A or IP 2 Method A SUPPLIED WITH stand clamp mains lead and instruction manual CALIBRATION amp VERIFICATIO
238. SOLID BATH 12250 0 CALIBRATED AIR FLOW METER 12255 0 STEAM CALIBRATION KIT 12310 3 STEAM GENERATOR 12311 2 INSTALLATION KIT 12312 0 BEAKER EXTRACTION TOOL 12314 0 ROTARY COMPRESSOR 12320 01 10 12321 01 10 12351 01 10 12352 01 07 12355 01 10 12356 01 20 12381 01 10 12382 01 10 12383 01 10 12384 0 12430 01 10 12431 01 10 12460 01 10 12461 01 10 12500 0 12600 0 12600 001 12600 002 12600 003 12700 0 13032 3 13035 0 13140 0 13150 0 13160 0 13180 3 13220 2 13230 3 13401 0 13402 0 13403 0 13470 0 13661 3 13663 0 13664 0 13665 0 13666 0 13667 0 13740 0 13746 0 13747 0 13751 0 13770 311 13775 0 13802 0 13811 3 13815 0 HYDROMETERS BS 718 SERIES M50SP HYDROMETERS BS 718 SERIES L50SP HYDROMETERS ASTM E100 SERIES HYDROMETERS ASTM E100 SERIES HYDROMETERS ASTM E100 SERIES HYDROMETERS ASTM E100 SERIES THERMO HYDROMETERS ASTM E100 SERIES THERMO HYDROMETERS ASTM E100 SERIES THERMO HYDROMETERS ASTM E100 SERIES JET TURBINE FUEL HYDROMETER HYDROMETERS BS 718 SERIES M50SP HYDROMETERS BS 718 SERIES L50SP HYDROMETERS BS 718 SERIES M50 HYDROMETERS BS 718 SERIES L50 HYDROMETER JAR PORTABLE DENSITY MEASUREMENT KIT DENSITY STANDARD DENSITY STANDARD DENSITY STANDARD HYDROMETER CYLINDER STAND ABEL FLASH POINT TESTER HEATER ASSEMBLY IP74F with collar pack of 2 IP2F with collar pack of 2 IP75F with collar pack of 2 ELECTRIC STIRRER TAG CLOSED CUP TESTER SEMI AUTOMATIC TAG OPEN C
239. SORIES Pensky Martens SPECIFICATIONS OPTI ONAL Stirrer Two speed for ASTM D93 13470 0 THERMOMETER FERRULE AND ADAPTOR to mount thermometers pack of 2 IP 34 Methods A and B 13663 0 SETARAMP CONTROLLER for optional automated temperature control Temperature range Ambient to 370 C 13664 0 PROBE ASSEMBLY for use with 13663 0 Pensky Martens Ramp Rate Variable manually controlled 13665 0 OPEN FLASH CLIP AND THERMOMETER COLLAR converts to open cup for IP 35 BS 2000 Part 35 m 13666 0 BUTANE REFILL CONTAINER pack of 10 Bow 13667 0 PORTABLE GAS TANK with on off switch regulator and ignitor use with Butane refill container 13666 0 Voltage 110 120V 60Hz 71001 0 SETA VENT portable fume extractor and draught excluder excluding flexible ducting 220 240V 50 60Hz 99910 0 PORTABLE DIGITAL BAROMETER 750 to 1150 mbar absolute for details see page 145 Size HxWxD 32 x 31 x 29cm 45000 0 SETPLUS EXTENDED 12 MONTH WARRANTY THERMOMETERS ASTMS9C IP15C or ASTM9F IP15F or ASTM10C IP16C or ASTM10F IP16F or ASTM88C or ASTM88F CALIBRATION VERIFICATION amp TRAINING 99851 0 MULTI TEST VERIFICATION MATERIAL ASTM 093 IP 34 Gas Oil for details see page 150 99853 0 MULTI TEST VERIFICATION MATERIAL ASTM 093 IP 34 Gas Oil for details see page 151 99908 0 BIO MULTI TEST VERIFICATION MATERIAL Gas Oil for details see page 151 99880 0
240. SSORIES Melting Point Apparatus REQUIRED THERMOMETERS Melting Point ASTM14C IP17C or ASTM14F IP17F Bath ASTM34C IP21C SPECIFICATIONS Sewer mmm 21400 0 Thermometers supplied separately SetaAnalutics Particulates residues amp composition testing for petroleum products e Hydrogen Sulphide H S e Particle Counting FAME in Jet H S Analyser WWW Sera analuflcs co UK AvCount Particle Counting FAME in Jet refinery E info seta analytics com T 44 0 1932 575000 w www seta analytics co uk Penetration Penetrometers 17000 SERIES PENETROMETERS ASTM D5 D217 D937 D1403 D1321 D1831 D2884 IP 49 IP 50 IP 179 IP 310 IP 376 BS 1377 BS 2000 Parts 49 50 amp 179 BS 2499 Part 3 EN 1426 ISO 2137 DIN 51 579 DIN 51 580 NF T60 119 NF T60 132 NF T60 140 NF T66 004 JIS K2220 17500 0 PENETROMETER Microprocessor controlled Penetration range 0 to 700 Pen 70mm Timer range 1 to 9999 seconds Automatic plunger release and retention Flexi light RS232C interface The 17500 0 Setamatic Penetrometer is a microprocessor controlled instrument with a range of 0 to 70mm 700 Pen Plunger release and retention is automatic and results are shown on the digital display in either millimetres or pen units Soak and penetration times may be set from 0 to 9999 seconds An RS232C interface is provided for connecti
241. STANDARD 114 155 15384 0 PLATINUM COBALT COLOUR REFERENCE STANDARD 114 155 15385 0 PLATINUM COBALT COLOUR REFERENCE STANDARD 114 155 15386 0 SAYBOLT COLOUR REFERENCE STANDARD 114 155 15387 0 SAYBOLT COLOUR REFERENCE STANDARD 114 155 15388 0 SAYBOLT COLOUR REFERENCE STANDARD 114 155 15389 0 SAYBOLT COLOUR REFERENCE STANDARD 114 155 15400 4 OXIDATION STABILITY CONSOLE BATH 66 15450 3 AUTO OXIDATION CONTROL UNIT 66 67 68 69 15455 0 TRANSDUCER 67 68 15456 0 CALIBRATION PLUG 67 15460 0 OXYGEN CHARGING AND PURGING KIT 64 67 15550 2 OXI COR BATH 68 74 15600 0 PRESSURE GAUGE 66 67 68 69 117 15611 2 PORTABLE CAMBRIDGE PRESSURE RECORDER 66 67 68 69 15620 2 OXYGEN CHARGING LEAD 67 68 123 15630 0 CHARGING LEAD HIGH PRESSURE 97 119 123 15640 0 PRESSURE TRANSMITTING CAPILLARY 67 15650 0 WATER PURIFIER 61 66 68 76 87 102 137 15800 4 OXI FEED PRESSURE VESSEL 66 68 15802 0 OXIDATION VESSEL 66 68 69 15803 0 VESSEL CLAMP 66 68 69 15805 0 SPANNER 66 68 69 15810 0 LINER pack of 3 66 68 69 15850 4 AIR RELEASE VALUE APPARATUS 104 15860 0 TEST VESSEL 104 15865 0 DIGITAL THERMOMETER AND THERMOCOUPLES 104 15870 4 CIRCULATING WATER BATH 104 138 15875 0 TEST JAR HOLDER 104 15880 6 DENSITY BALANCE 104 16120 2 SETACLEAN TOTAL SEDIMENT TESTER 86 16125 0 DIGITAL THERMOMETER AND PROBE 86 104 16130 3 STEAM GENERATOR 86 87 137 16150 2 THERMOMETER 86 16155 4 FUEL OIL AGEING BATH 86 16156 0 CONICAL FLASK pack of 10 86 16157 0 AI
242. STER 117 DUAL EXTRACTION APPARATUS 94 DYNAMIC VISCOSITY 32 39 EFFUSIOMETER SCHILLING 116 135 EMULSION CHARACTERISTICS PETROLEUM OIL 105 ENERGY REGULATOR 18 ESTERCHECK 90 EVAPORATION BATH 93 Subject Page EVOCHROM DIESEL SYSTEM 91 EVOCHROM JET FUEL SYSTEM 91 EVOCHROM SDA SYSTEM 91 EXISTENT GUM BY JET amp AIR EVAPORATION 87 EXTRACTION SEDIMENT IN CRUDE amp FUEL OILS 86 WICK APPARATUS 20 FAME IN JET INSTRUMENT FIJI 89 FIA FLUORESCENT INDICATOR ADSORPTION 92 FIJI FAME IN JET INSTRUMENT 89 FILTER BLOCKING TENDENCY 83 FILTRATION KIT 82 FILTRATION TESTER 83 FLAME GAUGE BURNING TEST 21 FLASH POINT TESTERS ABEL 5 18 ACTIVE COOL 12 AUTOMATIC 2 8 10 11 CLEVELAND 6 19 MULTIFLASH 2 8 PENSKY MARTENS 4 18 SMALL SCALE SETAFLASH 9 16 TAG 7 17 FLOW CUPS AFNOR 47 B SERIES 47 BS ISO 47 FORD 47 ZAHN 4 FLOWMETERS TUBES 70 71 BUBBLE 71 PORTABLE 148 FLUORESCENT GEL 92 FOAMING CHARACTERISTICS DIFFUSER VERIFICATION KIT 102 103 149 DUAL TWIN FOAM TEST BATHS 102 MOTT DIFFUSER 102 NORTON STONE 102 QUAD BATH CONVERSION KITS 102 FORD FLOW CUPS 47 FOUR BALL LUBRICANT TESTER 98 99 FOUR WAY MICRO PENETRATION CUP 61 FREEZE VALVE LPG 117 FREEZING POINT 53 GARDNER COLOUR REFERENCE STANDARDS 114 155 COLOUR SCALE 113 GAS CONTROL VALVE 29 TANK PORTABLE 15 17 19 GASOLINE ULLAGE PASTE 122 GAUGES DEW POINT 117 VAPOUR PRESSURE 25 26 PRESSURE 25 26 66 69 117 GAUGING amp SAMPLING 120 123 GLASS BEADS 85 GLASS LINER amp PTFE
243. STM D1401 3 position semi automatic instrument Integral backlighting for improved precision 54 82 C 1 C 3 stirrers independently controlled Programmable test and measurement time The Herschel Emulsifier is a three station Herschel Emulsifier for testing the water separability of petroleum oils and synthetic fluids using the ASTM D1401 test method The bath can be operated at either 54 C or 82 C The three test stations operate independently of each other ina common bath The stirrer for each test station rotates at a fixed speed of 1500rpm and is lowered or raised automatically Audible prompts advise the user when to take measurements and also signify the end of the test The interval between audible prompts and the total duration of the test are programmable SUPPLIED WITH 3 glass cylinders mains lead and instruction manual SPECIFICATIONS Bath Temperature Range 54 C and 82 C switchable Bath Capacity 4 litres approx Temperature au 1 C 54 C 1 C 82 C OOM 96600 3 HERSCHEL EMULSIFIER ASTM D1401 IP 412 ISO 6614 NF T60 125 5 test and 2 pre heat positions Consistent emulsification conditions 25 to150 C temperature range 50 to1800 rev min variable speed stirrer RS232 interface A heated bath with stirrer to allow water and a test sample to be emulsified consistently prior to measuring the time taken for separation to occur The unit accommodates up to seven test ve
244. Setalert remote alarm option Filter housing and filter packs are available according to test method requirements The Seta Multi Filtration Tester is a unique and flexible instrument designed to test distillate fuels including gas oil gas turbine fuel kerosine diesel biodiesel and biodiesel blends It performs both existing IP 387 D2068 and D6426 methods and offers the possibility of testing other types of fuel and adopting future filtration and filterability test procedures MFT is microprocessor controlled and provides a simple user interface using 2 buttons and the Seta Multifunctional And Rotational Test SMART control feature in conjunction with a backlit alphanumeric 4 line display The SMART control is exceptionally easy to use for selecting different tests setting parameters and for calibration of the temperature and pressure sensors The display provides the operator with test procedure information as well as indicating the selected test method sample temperature pressure volume and the test result A printer can be connected to provide a permanent record of the test parameters results and a filterability graph The software permits the operator to set the test volume of liquid up to 1 litre and a maximum pressure of 200kPa This allows both specification testing and gravimetric tests to be carried out in conjunction with the appropriate filters and holders The fuel sample is drawn from the integral fuel reservoir by the
245. TAVIS DOUBLE 6 KINEMATIC AUTO VISCOMETER ASTM D7279 Houillon Method Correlates with ASTM D445 D446 D2270 IP 71 IP 226 BS 188 BS 2000 Part 71 BS 4459 EN 3104 ISO 2909 ISO 3104 FTM 791 305 NF T60 100 NF T60 136 JIS K2283 Two independently controlled baths Up to 6 viscometer tubes per bath Micro samples Two tests per tube from a single sample Automatic tube cleaning and drying Control and data analysis software The Setavis Double 6 KAV is a compact bench top automatic kinematic viscometer equipped with two baths that each accept up to six kinematic viscometer tubes Applications include research process and batch control Suitable for testing both transparent and opaque samples over a wide range of products including lubricants transformer oils and used oils Rapid test times and high sample throughput are achieved by using Setavis Auto Duplex tubes which have two measurement zones doubling the number of results per test The baths will also accept manual Houillon type viscometer tubes Precision optical detectors eliminate timing errors due to operator reaction time and parrallax errors The fully automatic cleaning drying reduces the downtime between sample injections SUPPLIED WITH Setavis KAV software one 6 way Autoclean module tubing connecting and mains leads and instruction manual Note Supplied without viscometer tubes or thermometers refer to the accessories section This equipment requires to
246. TING B BIO d SETAPLUS EXTENDED WARRANTY AVAILABLE 16600 2 Test Well Positions 16600 2 Glassware amp Flowmeters supplied separately SPECIFICATIONS Seta Part No 16600 2 16620 2 50 to 375 C 50 to 375 C Temperature Stability 0 5 C 0 5 C Test Wells 12 x 27mm Temperature Range 6 x 27mm 6 x 39mm 3xb5b1mm 220 240V 50 60Hz 220 240V 50 60Hz ANM saw Size HxWxD Bath 48 x 45 x 49cm Flow Control Unit 44 x 35 x 26cm Temperature Controller 26 x 12x 6cm Weight Bath 90kg Flow Control Unit 11kg each Temperature Controller 2kg 48 x 45 x 49cm 44 x 35 x 26cm each 26x12x6cm FLOWMETER SPECIFICATIONS Seta Part No Flow Rate l hr Conditions 16601 2 0 15 to 2 05 Oxygen Q 0 4 bar g and 21 C 16602 2 0 3 to 3 9 Air Q 0 4 bar g and 21 16603 2 0 8 to 10 8 Air Q 0 4 bar g and 21 C 16608 0 1 0 to 17 Air Q 0 4 bar g and 21 C Accuracy 2 full scale 2 full scale 2 full scale 1 full scale www stanhope seta co uk 16620 2 SETA HIGHTEMP BATH 12 WAY 12 test wells for 27mm glassware Up to 12 simultaneous tests Similar to the 16600 2 Seta Hightemp bath the 16620 2 can accept up to twelve 27mm oxidation cells The flow control unit is supplemented by a second unit that provides places for a further six flowmeters supplied separately thus allowing 12 simultaneous tests SU
247. TM12C IP64C ASTM12F IP64F PRESSURE CERTIFICATE WORKS 22220 4 with 22150 5 installed 22090 0 sampling LPG SAMPLING CYLINDERS ASTM D1265 IP 51 obs IP 104 obs IP 181 obs ISO 4257 BS 2000 Part 104 obs BS 5309 Parts 2 amp 3 NF M41 001 46bar 670psi maximum working pressure single and double valve models 1 8in BSP connections Outage tube on double valve versions 1316 Stainless steel body and valve A range of heavy duty stainless steel single and double valve sampling cylinders suitable for drawing LPG samples from pressurised storage and transferring them to laboratory equipment The outage tube end is marked on double valve cylinders SINGLE VALVE SAMPLING CYLINDERS 100ml 20510 4 20470 5 PRESSURE CERTIFICATE WORKS DOUBLE VALVE SAMPLING CYLINDERS 46bar 670psi 46bar 670psi capaci y lupe 11 21520 4 50ml 206 325 46bar 670psi 21530 4 100ml 20 40 5 46bar 670psi 21540 4 200ml 20 38 6cm 46bar 670psi 21550 4 250ml 20 41 7cm 46bar 670psi 20470 5 and 21560 5 21560 5 500ml 20 41 5cm 46bar 670psi Sampling Cylinders 21600 4 1000ml 20 57 4cm 46bar 670psi 21620 4 2000ml 20 66 3cm 46bar 670psi 21690 4 4000ml 20 105 5cm 9 85 46bar 670psi Note 21620 4 and 21690 4
248. TY VISCOSITY STANDARDS for details see page 48 99928 0 SETATHERM precision logging digital thermometer optimised for verification of viscosity baths for details see page 129 Note Other items which may be required include Solvents for tube cleaning CONSUMABLES Setavis Double 6 Kinematic Auto Vis 22420 0051 JO RING PIPESSEAE 44 0 1932 564391 1F1 44 0 1932 568363 sales stanhope seta co uk w www stanhope seta co uk 33 Viscosity Kinematic Capillary SETAVIS MANUAL KINEMATIC VISCOMETERS 83542 0 83541 3 SETAVIS DOUBLE 6 KINEMATIC VISCOMETER ASTM D7279 Houillon Method Correlates with ASTM D445 D446 D2270 IP 71 IP 226 BS 188 BS 2000 Part 71 BS 4459 EN 3104 ISO 2909 ISO 3104 791 305 NF T60 100 NF T60 136 JIS K2283 Two independently controlled baths Temperature range 0 to 150 C Up to 6 viscometer tubes per bath Integral 6 channel digital timer In situ tube cleaning with integral vacuum pump The 83542 0 is a manual version of the 83545 3 automatic kinematic viscometer The instrument is a bench top stand alone instrument comprising two temperature controlled baths each providing capacity for up to six Setavis viscometer tubes and an integral 6 channel timer An internal vacuum pump and collector assist in cleaning and drying the viscometer tubes while still installed in the equipment SUPPLIED WITH mains lead and instruction man
249. Test Name SIMDIS IBP SIMDIS 10 SIMDIS 50 SIMDIS 90 SIMDIS 95 SIMDIS FBP ASTM Method D2887 IP 406 D2887 IP 406 D2887 IP 406 D2887 IP 406 D2887 IP 406 D2887 IP 406 Range 120 to 190 C 177 to 242 C 260 to 290 C 320 to 354 C 335 to 369 C 350 to 414 C Amount Test 1ml 1ml 1ml 1ml 1ml 1ml Amount Test 1ml 1ml 1ml 1ml 1ml 1ml Reference Materials amp Standards Viscosity VISCOSITY STANDARDS Full compliance to ASTM IP amp other method protocols Manufactured under ISO 17025 quality standards UKAS Certified Supplied in 500 ml containers Tamper evident packaging for security and proof of integrity Valid for 2 years Viscosity standards supplied by Seta are exactly equivalent to and interchangeable with other recognised viscosity standards that adopt the reference numbers shown in the product table listed below as specified in many international test methods and often referred to for calibration requirements Seta supplied viscosity standards are manufactured in full compliance with ASTM D2162 Note The viscosity values in the following table are approximate and are for guidance in choosing the appropriate standard only The actual values will be indicated on the container CALIBRATION CERTIFICATE UKAS GENERAL PURPOSE VISCOSITY STANDARDS 154 KINEMATIC VISCOSITY mm S cSt SAYBOLT VISCOSITY Standard Seta 20 00 C 25 00 3778 4000
250. UMP amp REGULATOR 82 22124 0 PRESSURE GAUGE 117 19750 2 MITUTOYO MICROSCOPE 98 22125 0 THERMOMETER 117 19800 6 4 BALL LUBRICANT TESTER 99 22126 0 THERMOMETER 117 19820 0 SHEAR STABILITY HEAD 98 22127 0 THERMOMETER 117 19830 3 TEMPERATURE CONTROL SYSTEM 98 22128 0 TRIPOD 117 19840 0 HEATING PAD AND CONNECTING LEAD 98 22130 2 PRE COOLING APPARATUS 117 19850 3 TEMPERATURE CONTROLLER INDICATOR 98 22150 5 LPG CORROSION PRESSURE VESSEL 71 118 19860 0 THERMOCOUPLE 98 22159 0 RECEIVER 25ml pack of 3 29 19870 0 RACK 98 22160 0 RECEIVER 100ml pack of 3 29 93 117 29 100 117 117 16 77 118 24 24 71 118 77 118 26 26 26 26 24 24 23 22 136 25 24 25 26 25 25 25 25 25 25 26 26 26 26 26 116 135 26 46 18 116 135 116 135 116 135 116 135 116 135 116 135 21 46 47 59 68 71 76 83 93 97 100 102 103 117 141 148 149 Part Number 22161 0 RECEIVER 200ml pack of 3 22170 0 WEATHERING TUBE 100ml pack of 3 22180 0 WATER BATH 22190 0 COPPER TEST STRIP pack of 30 22210 3 REID VAPOUR PRESSURE BATH 22210 301 VESSEL SUPPORT BRACKET pack of 2 22220 4 CORROSION TEST BATH 22230 0 BRACKET pack of 3 22300 2 MAIN CHAMBER 22310 2 20 ULLAGE CHAMBER 22320 2 33 13 ULLAGE CHAMBER 22330 0 CORROSION RESISTANT SAMPLING CONNECTOR 22400 0 REID PRESSURE CYLINDER ASSEMBLY 22410 0 REID PRESSURE CYLINDER ASSEMBLY 22420 033 SEPTUM pack of 2
251. UP NO 3 23780 0 ZAHN CUP NO 4 23790 0 ZAHN CUP NO 5 24250 0 CLAMP 24401 0 DISTILLATION FLASK 500ml 24402 0 DISTILLATION FLASK 1000ml 24403 0 FLASK 150ml 24404 0 FLASK 250ml 24410 4 DISTILLATION FLASK HEATER 24415 2 DISTILLATION FLASK HEATER 24440 0 CONDENSER 24445 0 DRYING TOWER amp STOPPER 24450 0 RECEIVER 2 0ml 24460 0 RECEIVER 3 0ml 24465 0 RECEIVER 5 0 24470 0 RECEIVER 7 5ml 43 36 37 36 37 36 37 36 37 46 47 47 47 47 47 47 47 4 47 47 Index Product Number Part Number Page 24480 0 RECEIVER 10 0ml 31 24490 0 RECEIVER 12 5ml 31 24495 0 RECEIVER 25 0ml 31 24497 0 RECEIVER 25 0ml 31 24500 0 STEEL STAND 31 53 55 93 103 142 24510 0 RECEIVER 25 0ml 31 24520 0 CLAMP 31 93 103 24530 4 DISTILLATION FLASK HEATER 31 93 24540 4 DISTILLATION FLASK HEATER 31 93 24600 0 UNIVERSAL STIRRER 54 55 142 24630 0 FLEXIBLE DRIVE AND PULLEY pack of 2 142 24640 0 STIRRER ROTOR 54 55 142 24650 2 BOSSHEAD 31 93 103 24680 2 RECIPROCATING STIRRER 53 25000 3 54 55 72 86 93 103 137 25300 0 MOULDING PLATE 54 26000 0 LIQUID RECOVERY SYSTEM 10 14 15 16 26500 0 BURNING RATE TEST RIG 21 30000 0 SETAFLASH SERIES 3 CLOSED CUP TESTER 13 30005 0 ADAPTOR FOR 12V POWER SUPPLY 14 16 30006 0 CARRY CASE 14 16 31000 0 SETAFLASH SERIES 3 OPEN CUP TESTER 16 33000 0 SETAFLASH SERIES PLUS CLOSED CUP TESTER 13 33200 2 SETAFLASH SERIES 3 ACTIVE COOL 12 33205 0 PORTAB
252. UP TESTER BURNER BURNER BURNER THERMOMETER FERRULE AND ADAPTOR pack of 2 PENSKY MARTENS CLOSED CUP TESTER SETARAMP CONTROLLER PROBE ASSEMBLY OPEN FLASH CLIP AND THERMOMETER COLLAR BUTANE REFILL CYLINDER pack of 24 PORTABLE GAS TANK THERMOMETER FERRULE AND ADAPTOR pack of 2 DRAUGHT SCREEN SETALASH SOLID SAMPLE DISPENSER THERMOMETER 0 to 110 C SYRINGE 4ml THERMOMETER 100 to 300 C GAS BURNER SEMI AUTOMATIC CLEVELAND OPEN CUP TESTER PROBE ASSEMBLY 14 16 8 10 14 95 14 16 21 19 19 Part Number 13870 0 COOLANT MODULE 13880 0 METAL COOLING BLOCK 14010 4 VOLUME METER 14015 0 DRYING TOWER 14019 0 AIR PUMP AND REGULATOR 14020 002 GRADUATED CYLINDER 1000ml pack of 2 14020 006 CYLINDER FOOT pack of 2 14020 5 SETAFOAM DUAL TWIN FOAM TEST BATHS 14021 0 VERIFIED NORTON STONE AND TUBE 14023 0 VERIFIED MOTT DIFFUSER AND TUBE 14026 0 TEMPERATURE PROBE AND INDICATOR 14028 201 DIGITAL MANOMETER 14028 4 VERIFICATION KIT FOAM 14029 0 RACK FOAM CYLINDER 14030 2 AIR PUMP 14031 0 AIR PUMP 14050 0 CLEANING NEEDLE 14060 0 TWIN COLUMN ADSORPTION APPARATUS 14065 0 SILICA GEL 1kg 14066 0 FLUORESCENT GEL 40g 14070 3 VIBRATOR UNIT ADSORPTION 14080 0 STANDARD ADSORPTION COLUMNS set of 2 14090 0 PRECISION TRUE BORE ADSORPTION COLUMNS set of 2 14120 0 HYPODERMIC NEEDLE pack of 5 14181 2 QUAD LOW TEMPERATURE BATH CONVERSION KIT 14191 2 QUAD HIGH TEMPERATURE BATH CONVERSION KIT 14300 3
253. VE SAMPLING CYLINDERS SETA Part s Height e T Outage Tube Diameter Maximum SWP 20510 4 50ml No 21 2cm 3 8cm 46bar 670psi 20470 5 100ml No 25 2cm 2 8cm 46bar 670psi PRESSURE CERTIFICATE WORKS DOUBLE VALVE SAMPLING CYLINDERS S Diameter Maximum SWP 32 5cm 46bar 670psi 40 5cm 46bar 670psi 38 6cm 46bar 670psi 41 7cm 46bar 670psi 41 5cm 46bar 670psi 1000ml 57 4cm 46bar 670psi 2000ml 66 3cm 46bar 670psi 4000ml 105 5cm 46bar 670psi Outage Tube Note 21620 4 and 21690 4 not for sale in the EU A double valve cylinder fitted with 21502 2 collars D PRESSURE CERTIFICATE WORKS 21770 0 21790 0 15630 0 21800 0 ACCESSORIES Sampling Cylinders OPTIONAL 15620 2 SETA CHARGING LEAD LOW PRESSURE Length one metre for pressures up to 14 bar 200psi 1 Fitted with Schrader quick connect couplings male one end female the other E 15630 0 SETA CHARGING LEAD HIGH PRESSURE Length one metre for pressures up to 46 bar 670psi Braided stainless steel outer cover Fitted with Hansen high pressure quick connect couplings male one end female the other 21770 0 SETA RELIEF VALVE HIGH PRESSURE for maximum safety mounted between sample source and charging lead or charging lead and sampling cylinder One end fitted with 1 8in BSP female the other 1 8in BSP male Set to relieve at 46 bar 670psi 21780 0 SETA RELIEF VALVE LOW PRESSURE for maximum safety mounted bet
254. VISCOMETER NO 1 46 REFRIGERATION CIRCULATION UNIT 139 REFRIGERATOR LABORATORY 140 REID PRESSURE CYLINDER ASSEMBLY 24 REID VAPOUR PRESSURE RVP BATH 24 RELATIVE DENSITY LIGHT HYDROCARBONS 116 135 REMOTE COMMUNICATIONS SETALERT 142 RING amp BALL TEST UNIT 54 ROBOT OXIDATION BATH 64 ROLL STABILITY TEST OF LUBRICATING GREASE 63 100 ROTATING BOMB OXIDATION TEST 64 RULE WATER FINDING 122 RUST PREVENTING CHARACTERISTICS TEST BATH 78 Subject Page TRUE BORE ADSORPTION COLUMNS 92 WEATHERING TUBE 117 VISCOMETER TUBES 40 42 VISCOMETER TUBES SETAVIS 33 35 GREASE DROP POINT APPARATUS 55 DROP POINT OVEN 56 ROLL STABILITY 63 100 SEPARATION APPARATUS 106 GRINDING amp POLISHING RIG 78 WORKER 62 GUM EXISTENT IN FUELS 87 HALF SCALE CONE 60 HERSCHEL EMULSIFIER 105 HIGHTEMP BATH UNIVERSAL OXIDATION 70 71 HOT PLATE 137 HYDROGEN SULPHIDE ANALYSER 88 HYDROMETERS CYLINDER STAND 134 GLASS TYPES 132 JET FUEL 132 LPG BATH amp COOLER 116 135 PRESSURE 116 135 READING JAR 133 HYPODERMIC NEEDLE 92 SYRINGE 35 92 ICE BATH 117 ICOT 73 IGNITION QUALITY TESTER IQT 110 111 INDUCTION PERIOD METHOD 66 INHIBITED MINERAL OILS OXIDATION 64 70 71 73 INSOLUBLES TEST 96 INSULATION OILS DIELECTRIC STRENGTH 115 OXIDATION 70 71 73 ISOTHERMAL OXIDATION CORROSION TESTER 73 JET EVAPORATION 87 JET FUEL JF1 VISCOSITY STANDARD 48 154 HYDROMETER 132 KINEMATIC VISCOMETERS BATH 32 39 TUBES 33 35 40 42 KV THERMOMET
255. VISCOSITY STANDARD LOW TEMPERATURE VISCOSITY STANDARDS 27 C 16 6 F 26 5 C 15 7 F 184000 164400 KINEMATIC VISCOSITY mm S cSt Standard 26 11 C 26 C 14 8 F 15 F 3 504 95 380 152 500 148 400 25 5 C 13 9 F 133 600 25 C 13 F 120 400 23 33 C 10 F 2 360 65 157 477896 13 C 0 F 1145 32353 8 6 F 179 400 12 5 C 9 5 F 164 300 17 108 10 F 156 500 12 22 12 C 10 4 F 151 200 11 5 C 11 3 F 11 C 6 67 12 2 F 20 F 9 533 137 600 126 100 1 4 44 0 1932 564391 r 44 0 1932 568363 Le sales stanhope seta co uk www stanhope seta co uk Viscosity amp Colour Reference Materials amp Standards VISCOSITY STANDARDS SETAVIS VISCOSITY STANDARDS Setavis KAV Duplex Tubes should be individually verified or calibrated at the intended test temperature and nearest flow time using certified viscosity standards For calibration two standards are required for each tube to provide at least 50 difference in flow time as required by ASTM D446 VISCOMETER TUBES 40 C RANGE STANDARDS 100 C RANGE STANDARDS First Standard Second Standard First Standard Second Standard Nominal Tube Seta Part No Nominal Viscosity Nominal Viscosity Seta Nominal Viscosity Constant mm s mm s Part No mm s 99784 0 2 9 99785 0 5 7 99786 0 99787 0 99831 0 99786 0 99787 0 99833 0 99786 0 99832 0 99834 0 99789 0 99832 0 99787 0
256. Viscosity 150 C 151 4 C 0 05 TEMPERATURE CONVERSION FORMULAE 5 F 32 op C x 9 4 32 9 MERCURY LIQUID IN GLASS THERMOMETERS MERCURY LIQUID IN GLASS THERMOMETERS A 550mm long thermometer with a 76mm immersion depth Filled with a Yr non toxic green expansion medium CALIBRATION CERTIFICATE WORKS SUPPLIED WITH a works test certificate Add suffix Z to the part number ent to order a thermometer with a UKAS calibration certificate CALIBRATION CERTIFICATE UKAS NON MERCURY THERMOMETERS Seta Part No Works Calibrated UKAS Calibrated Range Graduations 99945 0 99945 0Z 5 to 105 C 0 1 C 99945 0 Temperature amp Fluid Density Thermometer Holders amp Digital Thermometers PROTECTIVE CASES amp HOLDERS PROTECTIVE ARMOUR THERMOMETER CASES A brass tube with a suspension ring at the top a perforated bulb cage and a slotted side for easy reading of the thermometer Suitable for most thermometers approx 8mm internal diameter 87500 0 305 thermometer length 87500 0 87520 0 87510 0 405 max thermometer length A non sparking design for use with ASTM IP tank dipping thermometers see table below to take sample temperature from a storage tank Fitted with a retaining handle at the top of the case for attaching a cord and a 100ml cup at the bottom for collecting the sa
257. WG One metre long plain one end to 1 8in BSP male 21850 0 SETA CONNECTOR PIPE copper 1 4in diameter x 208WG One metre long plain one end to 1 8in NPTF male 21501 3 SETA PROTECTION COLLAR prevents damage to valves stops rolling use as carry handle A double valve cylinder fitted with 21502 2 collars To fit 21560 3 and 21600 3 Sampling Cylinders 21502 2 SETA PROTECTION COLLAR prevents damage to valves stops rolling use as carry handle To fit 21540 3 and 21550 3 Sampling Cylinders Tank Sampling amp Gauging Sampling Cans amp Bottles LIQUID SAMPLERS SAMPLERS A range of vessels and accessories for collecting liquid samples from bulk storage and transport tanks Universal samplers can collect samples at a chosen distance from the base of the tank when the valve actuator contacts the bottom of the tank and operates the bottom valve Alternatively sample can be taken from any intermediate level via a snatch cord operated top valve Multi level samplers are only equipped with a snatch cord operated top valve and are used to collect samples from intermediate levels Note Multi level Samplers are not suitable for bottom sampling UNIVERSAL SAMPLERS SAMPLERS Bottom or Multi Level sampling ACCESSORIES Universal Samplers Automatic opening and closing bottom OPTIONAL valve 1 to 35 cm adjustable tank bottom sensor Snatch cord opening top valve Top valve latches open Top Hat prevents sample contamination
258. WORKS Note For 12 way operation an additional SetaOxflo Controller 16905 2 SETAPLUS EXTENDED WARRANTY AVAILABLE Is required 16645 0 SETA TOST BATH 6 WAY ALSO AVAILABLE PLEASE CONTACT STANHOPE SETA FOR DETAILS F No Em WEE BR WE VE S WP RM P ACCESSORIES TOST amp Oxidation Baths HEQVUIRED Temperature Range Ambient to 100 C Select from the table ITEMS REQUIRED FOR EACH TEST Temperature Control at 95 C Uniformity 0 1 C 11470 0 SILICONE CARBIDE PAPER 100 grit FEPA 28 x 23cm pack of 50 EM Stability 0 03 C 1 16905 2 SETA OXFLO CONTROLLER 6 way FOR 16640 0 ONLY Note required for 12 Lu Solid Block way operation only Power 2kW 16910 0 SET OF GLASSWARE comprises six each condensers test tubes delivery Voltage 220 240V 50 60Hz tubes and interconnecting tubing 16914 0 SAMPLE FILTERING KIT for ASTM D2274 only comprises filters filter Size HxWxD holder vacuum flask and vacuum pump Bath 50 x 25 x 64cm 16915 0 FILTRATION amp ACCESSORY KIT for ASTM D4310 only comprises filters Wtle Control Unit E filter holder weighing bottle separating funnel sampling tube syringe Weight dessicator vacuum filtering flask forceps and vacuum pump Bath 110kg 16916 0 FILTRATION KIT for ASTM Draft Method for BioDiesel and BioDiesel Oxflo Control Unit 11kg Blends comprises filters filter h
259. ack of 2 97 17190 2 UNIVERSAL PENETROMETER WITH INTEGRAL CONTROLLER 58 20565 0 MANIFOLD 97 17380 0 LIGHT WEIGHT PLUNGER 61 20570 0 BLAST BURNER pack of 2 97 17500 0 PENETROMETER 58 20580 0 BLAST BURNER pack of 2 97 17510 0 MANUAL GREASE WORKER 62 20800 0 OIL CONTENT OF WAX APPARATUS 107 17520 0 OVERFLOW RING 62 20850 0 GLASSWARE 107 17525 0 STAINLESS STEEL POT 62 20900 0 GREASE SEPARATION APPARATUS 106 17730 0 DIAL THERMOMETER 47 62 20950 0 GREASE SEPARATION APPARATUS 106 17740 0 BLANK LID 62 20980 0 GREASE SEPARATION APPARATUS 106 17790 0 STANOMATIC DUAL GREASE WORKER 62 20990 0 PRESSURE BLEEDING TEST CELL TYPE B 106 17800 002 CHURN PLATE 62 21001 2 RING AND BALL TEST UNIT 54 17910 0 QUARTER SCALE CONE 60 21003 2 RING AND BALL TEST UNIT 54 17950 0 ULTRA LIGHT WEIGHT PLUNGER 61 21140 0 SHOULDERED RING pack of 3 54 18000 0 OPTIONAL CONE 60 21141 2 SHOULDERED RING pack of 10 54 18050 0 ASTM IP OPTIONAL CONE 60 21142 0 STRAIGHT RING pack of 10 54 18051 0 STANDARD CONE 60 21143 0 TAPERED RING pack of 10 54 18060 0 HALF SCALE CONE 60 21144 0 BALL pack of 30 54 18080 0 SPECIAL FULL SCALE CONE 60 21160 3 BALLCENTRING GUIDE pack of 3 54 18101 0 PENETRATOR NO 1 60 21170 0 BEAKER 800ml 54 18102 0 PENETRATOR KIT NO 2 60 21200 0 1 APPARATUS 93 18103 0 PENETRATOR KIT NO 3 60 21300 0 EXTRACTION APPARATUS 86 18104 0 PENETRATOR KIT NO 4 60 21300 001 THIMBLE 8
260. age 137 ASTM40C THERMOMETER P80C o ASTM40C IP80C gt Note Other items which may be required include Silicone grease Solvents and acids Note ASTM D2274 specifies the use of a liquid bath 12 44 0 1932 564391 F 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk Oxidation Stability Oxidation OIL FILLED OXIDATION BATHS 16900 5 16960 0 SETA OXIDATION BATH WITH OXFLO CONTROLLER ASTM D943 D2274 D4310 ASTM D7462 Oxidation Stability of Biodiesel Blends B100 and Blends of Biodiesel with Middle Distillate Petroleum Fuel Accelerated Method IP 157 IP 388 DIN 51 587 BS 2000 Part 388 ISO 12205 ISO 4263 NF T60 150 TOST Test NF M07 047 6 position oil bath e Reliable digital thermostir unit Seta Oxflo Controller and flowmeters included Low liquid protection Overtemperature cut out An oil bath and oxygen flow control unit used for quantative analysis of the tendency of oils and fuels to form sludge acids and deposits when exposed to oxygen in the presence of metallic catalysts over extended periods The 35 litre oil bath can accept up to six sets of glassware The stirred oil is maintained to within 0 1 C at 95 by an integral thermostir unit that has been designed for continuous use over extended periods incorporating a stirrer motor well recognized for longevity The temperature measurement system uses a PT1000 probe to ensure long t
261. al 14740 0 1 litre Copper Inner 8 8cm 43cm 2 5 2 7kg Brass Outer 14700 0 14720 0 14801 0 14740 0 ACCESSORIES Sampling Cans OPTIONAL THERMOMETERS 14740 0 only IP 48C IP 49C IP50C 1P51C BACON SAMPLING VESSELS SAMPLING VESSELS Bottom opening valve Snatch cord or self actuated Valve stem locking device A sampler with a bottom opening valve used for non pressurised sampling The valve can be actuated at any depth by a snatch cord or self actuated when either the valve or its extender rod strikes the bottom of the storage tank BACON SAMPLING VESSELS Seta Part Capacity Diameter Length Weight Material 21711 0 950ml 8 0cm 38cm 3 2kg Nickel plated brass 21712 0 475ml 6 5cm 30cm 2 0kg Nickel plated brass 21711 0 ACCESSORIES BACON Sampling Vessels OPTIONAL 21715 0 EXTENDER ROD 7 5cm long 21716 0 EXTENDER ROD 15cm long 21717 0 EXTENDER ROD 30cm long 21718 0 EXTENDER ROD 45cm long Tank Sampling amp Gauging Sampling Cage Dip Tubes Tapes Weights amp Rulers SAMPLING CAGE l 14760 2 14810 0 SETA SAMPLING CAGE Fitted with cork brass discs and hook Threaded neck for 14770 0 sample bottle ACCESSORIES Sampling Cage REQUIRED 14770 0 SAMPLING BOTTLE 500ml capacity 14760 2 with amber glass screw lid 15cm high 8cm dia 14770 0 fitted screws into 14760 2 Sampling Cage pack of 28 SPECIFICATIONS TUBES TUBES
262. al 305 11F 28F Cleveland Open Flash 20 to 760 F 5 F 25 310 46F 66F Kinematic Viscosity 119 5 to 124 5 F 0 1 F total 305 12C 64 Density Wide Range 20 to 102 C 0 2 C total 420 47C 35C Kinematic Viscosity 58 6 to 61 4 C 0 05 C total 305 12F 64 Density Wide Range 5 to 215 F 0 5 F total 420 47F 35 Kinematic Viscosity 137 5 to 142 5 F 0 1 F total 305 13C 47C Loss on Heat 115 to 170 C 0 5 C total 155 48C 90 Kinematic Viscosity 80 609 to 83 4 C 0 05 C total 305 14 17C Wax Melting Point 38 to 82 C 0 1 C 79 375 48F 90F Kinematic Viscosity 177 5 to 182 5 F 0 1 F total 305 14F 17F Wax Melting Point 100 to 180 F 0 2 F 79 375 49C Stormer Viscosity 20 to 70 C 0 2 C 65 305 15C 60C Low Softening Point 2 to 80 C 0 2 C 395 15F Low Softening Point 30 to 180 F 0 5 F total 395 5OF Gas Calorimeter Inlet 54 to 101 F 0 1 F total 468 16C 61C High Softening Point 30 to 200 C 0 5 C X total 395 51F Gas Calorimeter Outlet 69 to 116 F 0 1 F X total 468 16F High Softening Point 65 fe S925 aa 395 52C Butadiene Boiling Point 10 to 45 C 01 total 162 UC Saybolt Viscosity 19 to 27 C 01 total 275 54C 18 Congealing Point 20 to 100 6 C 0 2 C total 310 17F Saybolt Viscosity 66 to 80 F 0 2 F total 275 54F 18 Congealing Point 68 to 213 F 0 5 F total 310 18C 23C Reid Vapour Pressure 34 to 42
263. allow routine monitoring of instrument performance and are also particularly helpful in training personnel on new equipment and test methods We recommend the purchase of MTVM s with new instrumentation to assist with installation and commissioning Seta MTVMs are unique because unlike most other certified reference materials that are only suitable for validating a specific parameter value our MTVMs enable a user to validate different tests and instrumentation using the same sample material MTVMs are blended by a major multi national refining company in conformance with ISO 9001 and ISO IEC EN 17025 ISO Guide 25 and EN 45001 and tested internationally by a statistically significant number of laboratories to determine certified values Seta MTVMs are supplied in 500ml containers except 99856 0 which is 250ml and have an 18 month validity from date of supply Note Each MTVM sample provides a single value for all of the latest parameters shown in the tables The actual value of each test will fall within the range shown CERTIFICATE OF MEASUREMENT WORKS FOR ALL TEST METHODS COVERED BY THE MATERIAL 06 TECHNICAL DATASHEETS AVAILABLE SETA MTVM KEROSINE JET TURBINE FUEL 500ML Test Name i ASTM Method Range Amount test Distillation IBP D86 IP 123 EN ISO 3405 140 to 180 C 100ml Distillation 10 D86 IP 123 EN ISO 3405 159 to 188 C 100ml Distillation 50 D86 IP 123 EN ISO 3405 183 to 218 C 100ml Distillation 90 D
264. ample identity are output via the integral printer and RS232 port Calibration is automated and can be carried out at either full vacuum atmospheric pressure or high pressure A calibration certificate can be printed out SUPPLIED WITH 5ml syringe needles septum strips paper ink package flask mains lead and instruction manual CONSUMABLES Setavap Analyser 2 Years 2000 Tests 40000 007 PAPER INK PACKAGE 80000 016 SEPTUM STRIP pack 5 8 80000 017 FEASK USED SAMPLE pack Or nma 4 81003 001 SYRINGE 5ml c w LeurLock 1 81003 2002 NEEDEE for 1003 001 pack oi 2 sas 1 80009 0 SYRINGE 1ml c w LeurLock and needle 2 SPECIFICATIONS Test Temperature Range E 25 C below ambient to 100 C 45 F below ambient to 212 F 0 1 C 0 2 F EE Temperature Resolution 0 to 700kPa 0 1kPa 0 1psi Test Pressure Range Pressure Resolution Units of Pressure kPa psi Ibf in kg cm mbar mmHg inHg mM User selectable Reid Mode Display shows RVP equivalent Chamber Volume 15ml 1 better than 0 01kPa abs RS222C 110 120V or 220 240V 50 60Hz Switchable 200W Size HxWxD 35 x 45 x 37cm Weight 22 8kg Vacuum Requirement Computer Interface Voltage ACCESSORIES Setavap Analyse
265. an inner glass bath contained in a polycarbonate safety vessel a top mounted thermostir unit and a side mounted module containing two calibrated 14020 5 with Accessories flowmeters with control valves and protection shields Integral back lighting with an opaque reflector aids sample visibility and foam measurements The low temperature bath also has a cooling coil for use when the ambient temperature exceeds the required bath temperature ACCESSORIES Dual Twin Foam Baths and two air normalising coils to cool the air emerging from the high REQUIRED temperature bath test cylinders prior to passing to external volume meters m P One diffuser stone is required per Graduated Cylinder Select either The thermostir units provide precision temperature control to within 14021 0 VERIFIED NORTON STONE AND TUBE porosity and permeability verified 0 5 C across a temperature range of ambient to 100 C and feature a VY VERIFICATION CERTIFICATE Works low fluid level alarm Easy to remove stoppers ensure air tight seals and OR central location of the diffusers All air connections are via quick release 14023 0 VERIFIED MOTT DIFFUSER AND TUBE stainless steel porosity and connectors and the diffuser tubes can be used with either Mott diffusers permeability verified or Norton stones VERIFICATION CERTIFICATE Works SUPPLIED WITH four flowmeters four graduated 1000ml cylinders 14015 0 DRYING TOWER 300mm high for ASTM
266. and other false flash effects reducing the chance of mis interpretation of the test result and enhancing repeatability Barometric pressure is measured by an internal barometer and the correction is automatically applied to the test result The instrument is lightweight and suitable for mobile use when operated from the optional DC power adaptor SUPPLIED WITH 2ml syringe mains lead and instruction manual FOR SPECIFICATIONS ACCESSORIES amp CONSUMABLES SEE PAGE 14 BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE ENAA TECHNICAL DATASHEETS AVAILABLE SETAFLASH SERIES 3 ACTIVE COOL CORROSION RESISTING Corrosion resisting version of Setaflash 33200 2 The 33250 2 is similar to the 33200 2 with the addition of a corrosion resisting insert in the sample cup SUPPLIED WITH 2ml syringe mains lead and instruction manual FOR SPECIFICATIONS ACCESSORIES amp CONSUMABLES SEE PAGE 14 CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE TECHNICAL DATASHEETS AVAILABLE 33000 0 30000 0 Small Scale Flash Point Flash Point Smoke Point amp Sustained Burning SETAFLASH SERIES 3 PLUS CLOSED CUP TESTER ASTM D3278 D3828 D7236 E502 IP 303 obs IP 523 IP 524 IP 534 ISO DIN 3679 ISO 3680 BS EN 456 BS 3900 Part A13 BS 6664 Parts 3 amp 4 UN Class 3 Non viscous Flammable Liquids CHIPS Regulation
267. ata processed on an IBM compatible personal computer using the software provided SUPPLIED WITH software 33mm optical glass cell 50mm optical glass cell ASTM Colour 3 5 certified glass conformance filter spare lamp universal power supply and instruction manual SOFTWARE INCLUDED 15320 2 SETA LOVIBOND HIGH PRECISION COLORIMETER ASTM D156 D1209 D1544 D1500 D6045 IP 17 Method A amp B IP 196 BS 5339 BS 5859 ISO 2049 DIN 51 411 NF M07 003 JIS K2580 The 15320 2 is a high precision version of the 15260 4 Seta Multicolour Automatic Colorimeter The instrument provides determinations in Saybolt colour ASTM Colour Pt Co Hazen APHA Colour Gardner Colour Lovibond RYBN IP Units CIE values or spectral data An integral heater unit allows samples such as waxes to be maintained in a liquid state SUPPLIED WITH software 10mm 100mm 1 inch and 6 inch optical glass cells one of each Saybolt 10 calibrated glass conformance filter spare lamp universal power supply and instruction manual SOFTWARE INCLUDED CALIBRATION amp VERIFICATION MATERIALS Y Metho d lour Scale 15260 4 x 15320 2 IN pies m ASTM D1500 D6045 ASTM Colour 0 5 to 8 Units 0 5 to 8 Units Lubricating heating and diesel fuel oils ASTM D156 JIS K2580 Saybolt Colour 16 Darkest to 30 Lightest 16 Darkest to 30 Lightest Light Coloured Aviation Fuels kerosenes white mineral oils ASTM D6045 Saybolt Colou
268. ate proper control at ambient or near ambient temperatures THERMOMETERS ASTM63C ASTM63F ASTM64C ASTM64F ASTM17C ASTM17F IP38C Penetration Grease Workers FULL SIZE GREASE WORKERS ASTM D217 IP 50 ISO 2137 NF T60 132 791 311 JIS K2220 Note All Seta Full Size Grease Workers are supplied with brass grease pots and 51 x 1 4inch hole Worker Plates as standard Stainless steel grease pots SETA 17525 0 and or 240 x 1 16inch hole Churn Plates SETA 17800 002 can be specified at time of ordering 17790 0 DUAL GREASE WORKER Works two grease pots simultaneously Auto stop at up to 999 999 strokes 60 10 strokes per minute Heavy duty brass grease pot Stainless Steel option 51 x 1 4 inch hole Worker Plate 270 x 1 16 inch hole Churn Plate option Large bore cock for thermometer insertion Two grease working assemblies mounted on a cast aluminium base by dowel pins and quick release cams Each grease working assembly comprises a heavy duty grease pot 17790 0 Shown with optional Stainless Steel Pots with screw lid A plunger passes through the lid and is attached to a perforated metal Worker Plate A large bore grease cock allows excess U CDFfIFIP ATIQNG air grease to es
269. ated minimum Nitrogen Supply Regulated minimum Cooling System Computer supplied Input voltage Typical Footprint Typical Weight NE ay IO Constant Volume Combustion Chamber Pintle type single hole nozzle air driven injection pump Compressed air 20 9 0 1 0 21 7 bar 310 psi for Combustion process Compressed air Industrial Grade 12 1 bar 175 psi for Injection process Compressed Nitrogen Industrial Grade 3 5 bar 50 psi for Fuel Feed process Closed loop liquid to air 32 bit Windows Based Industrial Computer 120 220V 60 Hz 220 240V 50Hz Protected by an uninterruptable power supply UPS and isolating transformer 3x3x3m 300kg B Marre Te 81 a3 Tepe m Franz E 82 Bn 10 Shin E a 5775 Chi js Presa 394 irg Prene 1772 _ amp i4 20 Cetane Number Stanhope Seta are distributors for the Ignition Quality Tester in Europe and India In addion to the supply of the IQT equipment Stanhope Seta also offer a comprehensive set of support packages including site preparation IQT M installation and commissioning Stanhope Seta can also provide basic and advanced staff training and maintenance workshops on site and at our UK headquarters Combustion Chamber detail Cetane Ignition Delay Needle
270. ature range of ambient to 250 C 482 F with a stability of 0 03 C 0 1 above 150 C It is heated by a thermostir unit with a stand alone digital temperature controller A fine temperature adjustment control is fitted to the thermostir allowing very accurate temperature to be set An integral cooling coil when connected to a cold water supply provides precise control when the set temperature is near the ambient temperature of the laboratory The bath is fitted with a fail to safe thermal cut out and a drain tap Viscosity kits are available for Redwood No 1 Redwood No 2 Saybolt and Bitument tests Each kit contains two sets of flow cups and any additional components except thermometers and a stopwatch to carry out the relevant test 83201 2 and Accessories SUPPLIED WITH remote temperature controller mains leads interconnection lead and instruction manual Note Requires one of the viscosity kits listed in accessories ACCESSORIES Viscometer Bath SPECIFICATIONS JUIREI Temperature Range Ambient to 250 C 482 F 22750 2 DIGITAL STO PWATCH hand held 0 1s resolution Temperature Stability 003 up to 150 C 302 F for details see page 141 0 1 above 150 C 302 F 83250 0 SAYBOLT VISCOSITY D88 comprises Cup Adaptor qty 2 Saybolt Capacity 14 E Viscometer Cup qty 2 Universal Orifice Tip qty 2 Withdrawl Tube L pm _ Thermometer Support qty 2 Filter Funnel 60ml
271. ature time profiles and volume setpoints can be downloaded from a personal computer or entered via the control panel Up to 10 programs can be stored in the on board memory and can be modified whilst using the Learn facility The unit continually measures the temperature of vapour in the distillation flask the volume of distillate in the receiver and the time interval Whenever a setpoint is reached these parameters are recorded The readings are corrected automatically from data supplied by the integral precision electronic barometer The results memory can hold up to 28 datasets of 100 volume setpoints To ensure conformity to ASTM D86 the temperature in the flask is measured by a digital system that incorporates dynamic simulation models of ASTM 7C F and 8C F mercury in glass thermometers The probe carries an embedded calibration curve Re calibration can be carried out by the user via the distillation unit 97005 0 Typical Dean amp Stark Assembly ASTM D95 D244 D4006 E123 IP 74 IP 291 IP 358 BS Reference Methods Distillation DISTILLATION FLASK HEATERS 2000 Parts 74 amp 358 BS 756 ISO 3733 ISO 9029 API 2560 API MPMS Chapter 10 2 MPMS Chapter 10 5 791 3001 obs NF T60 113 JIS K2275 SPECIFICATIONS 24410 4 Suitable Flask Size 24415 2 24540 4 500ml JL Number of Heater Stations Voltage 110 120V 50 60Hz 220 240V 50 60Hz
272. be connected to a computer vacuum source and solvent containers DUAL BATHS The baths are independently temperature controlled within a range of ambient to 150 C allowing one bath to be set at 40 and the other at 100 C Each bath comprises a heater coil stirrer unit and a cooling coil for temperatures near ambient ensuring even temperature distribution Up to six viscometer tubes can be installed in each bath FAST FLOW TIMES Flow times are typically between 50 to 100 seconds The sample flows into the measuring section of the viscometer tube via a temperature equilibrium zone e HIGH SAMPLE THROUGHPUT An average test including cleaning can be completed in less than 15 minutes allowing a maximum of 24 samples per bath 48 separate test results per hour With 12 positions fully utilised typically 96 test results can be achieved per hour ENCLOSED AUTOMATIC CLEANING The Autoclean module can clean up to six viscometer tubes automatically After the sample is detected leaving the measuring section the tube is flushed with solvent and dried by air in preparation for the next sample Solvent usage is typically 10 to 20ml per test The Autoclean module can be connected to 2 alternative solvent supplies allowing samples with different compositions to be tested in the same tube The cleaning capacity can be expanded to 12 way with an optional kit 83575 2 MICRO SAMPLES The viscometer tubes only require a very small
273. cape during assembly and insertion of a thermometer SPECII IU AI IONS m The plungers are driven by a geared electric motor at 60 10 strokes Speed 60 strokes perminute 10 I per minute An automatic counter will stop the motor after a user Worker Plate 51 x 1 4 inch holes Optional Churn Plate 270 x 1 16 inch holes set number of strokes up to a maximum of 999 999 The safety guard puer incorporates a motor cut off switch i i oltage Z SUPPLIED WITH grease worker assemblies mains lead and x 220 240V 50 60Hz instruction manual 450W Size HxWxD 46 x 370 x 50cm SETAPLUS EXTENDED WARRANTY AVAILABLE L 38kg 17510 0 SETA MANUAL GREASE WORKER Light and medium greases Easy grip handle A grease working assembly identical to those used on the 17790 0 Stanomatic Dual Grease Worker with a sturdy handle attached to the top of the plunger for manual operation rT Ul ACCESSORIES Full Size Grease Workers x PTIONAL 17520 0 SETA OVERFLOW RING for capturing overflowed grease 17525 0 STAINLESS STEEL POT alternative to standard brass pot 17510 0 17730 0 SETA DIAL THERMOMETER bimetal type range 30 to 60 C 17740 0 SETA BLANK LID with lead seal and tommy bar used when heating eee ec 17800 002 CHURN PLATE with 270 x 1 16 inch diameter holes alternative to SPECIFICATIONS Worke
274. carrying handle to fit 21560 3 and 21600 3 Sampling Cylinders 21502 2 SETA PROTECTION COLLAR prevents damage to valves stops rolling use as a carrying handle to fit 21540 3 and 21550 3 Sampling Cylinders A double valve cylinder with low pressure charging components Temperature amp Fluid Density ASTM amp IP Thermometers ASTM THERMOMETERS All Seta ASTM IP thermometers are manufactured in accordance with ASTM E 1 and E 77 requirements B KEY A Graduations minimum B Immersion Depth in mm C Approximate Total Length in mm E Where numbers appear in both ASTM and IP columns they are jointly agreed equivalents gt ASTM THERMOMETERS ASTM E1 ASTM IP APPLICATION TYPE RANGE A B C ASTM IP APPLICATION TYPE RANGE A B C 1 Partial immersion 20 to 150 C 1 C 76 322 33F Low Aniline Point 36 5 to 107 5 F 0 5 F 50 420 1F Partial immersion 0 to 302 F 2 76 322 34C 21C Medium Aniline Point 25 to 105 C 0 2 C 50 420 2 62C Partial immersion 5 to 300 C 1 C 76 390 34F Medium Aniline Point 77 to 221 F 0 5 F 50 420 2 62F Partial immersion 20 to 580 F 2 F 76 390 35C 59 High Aniline Point 90 to 170 C 0 2 50 420 3C 73C Partial immersion 5 to 400 C 1 C 76 415 oor High Aniline Point 194 to 338 F 0 5 F 50 420 73F Partial immersion 20 to 760 F 2 F 76 415 36C Titer Test 2 to 68 C 0 2 C 45 405 5 1C Cloud and Pour 38 to 50 C 1 C 108 230 37C 77C Solvents D
275. ce 5a Goods delivered to United Kingdom destinations are covered by our transit insurance but subject to an excess policy Claims will only be considered in cases where the value of the claim exceeds 1000 00 pounds sterling Both the carriers and ourselves must be advised within 24 hours of receipt of goods in respect of shortages or breakages or in the event of non delivery within 28 days from invoice date 5b Insurance for goods for Export will be arranged by us and charged to the customer unless specifically agreed otherwise but subject to an excess policy Claims will only be considered in cases where the value of the claim exceeds 1000 00 pounds sterling Both carriers and ourselves must be advised within 24 hours of receipt of goods in respect of shortages or breakages or in the event of non delivery within seven days from despatch by air or within 10 days of expected date of arrival by sea 5c No liability is accepted in respect of any loss or damage caused by or consequent upon delay in delivery or non delivery from any cause whatsoever In particular deliveries offered ex stock are subject to the goods being unsold at the time of receipt of order 6 Payment Payments may be made by Advance Payment Visa or Mastercard credit cards or on terms of an Approved Credit Account To accommodate standard export terms Cash Against Documents or Letters of Credit may also be used Our sales order processing team will gladl
276. ce to corrosion of a polished copper strip when immersed in an LPG sample Comprises a seamless polished stainless steel vessel with two stainless steel needle valves with viton seals dip tube and O ring sealed cap 35bar 507psi safe working pressure 22150 5 CORROSION TEST BATH ASTM D1838 IP 411 ISO 6251 EN 26251 obs BS 2000 Part 411 BS 6924 NF M41 007 Temperature range ambient 5 to 100 C 3test stations Integral stirrer A stainless steel water bath that can accommodate up to three pressure vessels The bath is fitted with a combined heater and circulator with thermostatic temperature control and digital display A gabled stainless steel lid is supplied with the bath SUPPLIED WITH mains lead and instruction manual SPECIFICATIONS Temperature Range Ambient 5 to 100 C Stability 0 2 Capacity 38 litres Voltage 110 120V 50 60Hz 220 240V 50 60Hz Power 1 4kW Size HxWxD 60 x 35 x 33cm Weight 9kg SETA COOLING UNIT Permits LPG samples to be taken from pipelines or tanks Maintains the gas in liquid phase The unit comprises a nickel plated brass container fitted with an inlet cooling coil sampling outlet tube and pressure control
277. clude a check to ensure that the sample probe and flash detector are connected When in search mode the software limits the maximum temperature to 50 C above expected flash SUPPLIED WITH DIPS pod Test Area Ignitor Flash Detector Sample PRT interconnection leads and instruction manual Note 34000 0 Universal Base Unit required for operation For sub ambient tests a Cooling Boost Module 34008 0 and Cryostat 34006 0 are also required Method I mmm Small Scale Closed Cup Tests Rapid Equilibrium Non Equilibrium Flash No Flash Search mode for unknown samples Temperature Range Ambient to 300 C 10 C to 300 C with optional cryostat Barometric Correction Automatic Bath Solid Block Heating Side heaters Fan assisted Forced air or circulating liquid option Requires 34008 0 Cooling Boost Module and 34006 0 Cryostat Post Test Cooling Post Test Cool down Time 36 minutes Fan 90 C to 50 C 2 minutes Cryostat Ignitor Temperature Probe Quick fit coaxial gas jet electric hot wire user selectable Electric hot wire pilot light for gas jet Class A Platinum Resistance Thermometer C or F Flash Detection Thermocouple Gas Supply gas jet ignitor Cooling Supply Air Liquid Voltage Power Size HxWxD Laboratory gas 3
278. complete with drainage tray 84102 0 DENSITY MEASURING KIT adapter to allow use of glass hydrometers For tests at 15 C the 99300 2 bath is required for details see below 99300 2 MINI LOW TEMPERATURE BATH CIRCULATOR to provide chilled water if local supply exceeds 18 C for details see page 139 97100 0 VISCOMETER TUBE CLEANER for details see page 39 45001 0 SETAPLUS EXTENDED 12 MONTH WARRANTY VERIFILA ON A TRAINING PATIUIN PUAALTIUIN CX TL T VIENI VISCOSITY STANDARDS for details see page 48 SETATHERM precision logging digital thermometer optimised for verification of viscosity baths for details see page 129 Note Other items which may be required include Solvents for tube cleaning 99928 0 Kinematic Capillary Viscosity KINEMATIC VISCOMETER BATHS 84200 0 SETA KV 6 VISCOMETER BATH ASTM D445 D446 D2170 D2270 IP 71 IP 226 IP 319 BS 188 BS 2000 Parts 71 amp 319 EN 3104 EN 12595 ISO 3105 DIN 51 366 DIN 51 562 FTM 791 305 NF T60 100 NF T60 136 JIS K2283 Up to 6 viscometer tubes 50 litre oil water bath Temperature range ambient to 150 C Digital display with 0 01 C resolution Toughened glass front panel Integral back lighting The Seta KV 6 has a 50 litre temperature controlled bath that can accommodate up to six standard viscometer tubes Digital temperature control and an inbuilt cold water cooling coil provide accurate and s
279. contains the associated coolant system and an integral computer with the IQT M System Software ISS installed An easy to view flat screen colour monitor is mounted on an adjustable arm attached to the cabinet An electronics cabinet containing data aquisition and instrumentation circuitry and the control system is mounted on the side of the wheeled cabinet Manufactured by Advanced Engine Technology AET in Canada the IQT determines the delay between the injector needle lifting and the combustion pressure recovery point in a heated fixed volume combustion chamber This delay is highly correlated to the ASTM 0613 cetane number CN The IQT is connected to a Nitrogen supply for delivering the sample an Air supply to operate the injector and a 20 9 0 content Air supply for the combustion charge The combustion chamber is electrically heated The IQT M package comprises the Ignition Quality Tester cooling system wheeled cabinet electronics cabinet rugged industrial computer software monitor connecting cables flexible hoses for connection to the gas supplies and a toolkit Please refer to the accessories table for additional kits required for installation and operation gt N 92000 3 BIO FUEL TESTING SOFTWARE INCLUDED CALIBRATION amp VERIFICATION MATERIALS TECHNICAL DATASHEETS AVAILABLE Measuring Principle Injection System Combustion Air Supply Regulated minimum Air Supply Regul
280. cross 60 memories Download to a USB memory stick 16 Point calibration Smaller case size English Chinese or German language selection BIO FUEL TESTING OPTIONAL SOFTWARE AVAILABLE i TECHNICAL DATASHEETS AVAILABLE FUEL PARTICULATES SA1000 2 avcount combines an improved user interface and re packaged electronics with the accuracy and reliability of the pump and sensor from the original svcount in a more compact case The avcounte is controlled via icons or a virtual keyboard using the colour touch sensitive screen Results are displayed in real time and are simultaneously printed out on the compact integral printer The test methods embedded in avcounte cover a range of fuels lubricating oils and hydraulic fluids Test methods can be edited to create custom test profles Improved connectivity and better memory management allows results to be accessed printed out or downloaded to a memory stick via the USB port or to a personal computer via the RS232 Port The avcounte can also be controlled via the RS232 port avcounte utilises 16 point calibration and can be re calibrated on site by a Seta trained engineer Seta Analytics part no SA1000 0 amp SA1200 0 SA1000 2 Particle Size Range ISO 11171 4um to gt 70 150 11171 4um to gt 70um 150 4402 2um to gt 100 GOST17216 71 2um to gt 200um
281. ctable Microbial Activity Simple to use test paddles provide a go no go test for Hormoconis resinae HR in the sample Each paddle has two test pads low test has a cut off at 1509 1 ang high test has a cut off 2729001 n fuel Size UE SUPPLIED WITH beakers wipes safety glasses gloves instruction Weight net g manuals and carry case 86400 2 PORTABLE FUEL INTEGRITY TEST KIT Suitable for Jet fuel and other light distillate fuels Rapid check for presence of contamination Multiple tests in single kit Compact easy to carry rucksack Ideal for shipboard use A self contained kit of test equipment for rapid detection of contamination in fuels The kit has been designed to fit into a small purpose made rucksack enabling it to be easily transported to test sites which have only limited or difficult access It is ideally suited to shipboard use providing both rapid and easy verification of product integrity prior to off loading Size HxWxD 30 x 30 x 30cm The kit comprises of 5 key tests that allow go no go testing of fuels Weight 6 5kg Flashpoint ASTM D3828 using the Series 3 Closed cup tester ACCESSORIES Fuel Integrity Test Kit complete with syringes and portable gas supply Note An external 13770 311 SYRINGE 4ml mains power supply is required for this instrument Density An ATEX approved digital density meter Conductivity ASTM D2624 Using a digital conductivity meter Water Conten
282. cteristics of the sample are observed visually while the test flame is passed over the sample 31000 0 All functions are accessed via a two button keypad and the Seta Multifunctional And Rotational Test SMART control feature The digital display shows test parameters and instrument status An audible prompt is sounded when an action is required from the operator The instrument is lightweight and suitable for mobile use when operated from the optional 12 volt power supply adaptor SUPPLIED WITH 2ml syringe test flame height gauge mains lead and instruction manual BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE ACCESSORIES Setaflash Series 3 Open Cup Tester TECHNICAL DATASHEETS AVAILABLE one IUN AL uu 13666 0 BUTANE REFILL CYLINDER pack of 10 13746 0 DRAUGHT SCREEN SETAFLASH size HxWxD 36 x 48 x 24cm stainless steel 26000 0 LIQUID RECOVERY SYSTEM with pump and trap to extract and collect hot sample from cup for details see page 15 ODrPiriPiTInue 30005 0 ADAPTOR FOR 12V POWER SUPPLY OOOD JFEUIFIUATIUNS _ _ 30006 0 CARRY CASE size HxWxD 21 x 40 x 30cm Temperature Range Ambient to 300 C 45000 0 SETAPLUS EXTENDED 12 MONTH WARRANTY Sample Size 2ml CALIBRATION VERIFICATION amp TRAINING Ji THERMOMETER 0 110 Test Time 1 to 99 minutes 13751 0
283. d Viton Tubing 1 metre Quartz Timer Six Channel Timer Display Board Timer Power Supply Board Timer Counter Board Setavis Double 6 Kinematic Auto Vis 32 Knob for Fine or Clean Control Heatsink Compound Mains Lead 0 Ring Pipe Seal pack of 10 Temperature Indicator Assembly Dual Heater Assembly Tubing 3mm i d 3 metres Tubing 5mm i d 3 metres Tube Gland pack of 6 Bath Assembly Neon Indicator Light Clear PRT Probe Assembly Tube Dust Cover pack of 24 Heater Driver Circuit Board Assembly Temperature Control Circuit Board Analogue Circuit Board Assembly Timer Circuit Board Assembly Sensing Assembly Blanking Plugs pack of 5 Sensing Power Supply Power Supply Computer Lead Computer Disc Waste Module leads pair Push Button Switch Waste Module Solvent Valve Assembly 6 Way Autoclean Fitting Kit 33 Waste Module Solvent Valve Assembly Part Number 83700 5 83700 302 83700 303 83700 304 83750 3 83750 301 83750 303 83750 304 83750 305 83750 306 83750 307 83750 308 83750 309 84000 0 13663 004 50000 005 84000 001 84000 004 84000 005 84000 006 84000 007 84000 008 84000 009 84000 011 84000 017 84004 0 84200 0 15155 001 15155 003 15155 006 15157 001 84004 0 84200 001 84200 002 84200 003 84200 004 84200 005 84200 006 84200 009 84200 011 84200 013 84200 014 84200 015 84200 016 86000 3 86000 006 86000 020 86000 301 86000 302 86000 303 86000 305 86200
284. d LPG Jet A 1 Aviation Diesel Motor Motor Def Stan Turbine Fuel ASTM D975 Gasoline Gasoline 91 91 ASTM D1655 EN 228 ASTM D4814 Densit ASTM D1298 ASTM D1298 ISO 3675 ISO 3675 y IP160 IP 160 IP 160 IP 170 ASTM D56 ISO 2719 ASTM D93 i IP 523 524 D3828 IP 34 Flash Point ASTM D3828 ASTM D56 Distillation IP 123 ASTM D86 ISO 3405 ASTM D86 ISO 3405 ASTM D86 ASTM D86 IP 123 ASTM D3828 IP 123 IP 107 ASTM D1266 ASTM D1266 Sulfur IP 243 ASTM D1266 ASTM D156 ASTM D6045 Ereezina Point IP 16 ASTM D2386 g ASTM 2386 EN 23015 ASTM D2500 Cloud Point IP 219 EN 116 ASTM D6371 CFPP IP 309 Pour Point Viscosit IP 71 ASTM D445 ISO 3104 ASTM D445 ASTM D445 IP 71 IP 57 ASTM 01322 Smoke Point ASTM 01322 Conner Stri IP 154 ASTM D130 ISO 2160 ASTM D130 ISO 2160 ASTM D130 p ASTM D130 IP 154 IP 154 Existent Gum IP 131 ASTM D381 ISO 6246 ISO 6246 ASTM D381 ASTM D381 IP 131 IP 131 Aromatics IP 156 ASTM D1319 ASTM D1319 IP 156 ASTM D1319 ASTM D1319 4 ISO 10370 Carbon Residue IP 398 i EN 15195 ASTM D6890 Cetane Number IP 498 EN 13016 1 ASTM D5191 Vapour Pressure IP 394 Oxidation Stability 150 7536 IP 40 Ramsbottom Carbon ASTM D524 Residue Water and Sediment ASTM D2709 Water Total Sediment Ash ASTM D482 Hydrogen sulfide H S Particulates IP 565 II Lt 44 0 1932 564391 r 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk Aviation Gasoline ASTM D910 ASTM D1298 ASTM D86 ASTM D1266
285. d bath temperature probes are class A PRTs and flash detection is by a thermocouple Safety features include an initial dip to check that the sample is below its flash point at the start of the test and PRT checks to ensure that the correct probes are connected and are immersed in bath liquid or sample When in search mode the software limits the maximum temperature to 50 above expected flash An over temperature cut out is mounted on the base flange of the bath SUPPLIED WITH DIPS pod Test Area Ignitor Flash Detector Bath PRT Sample PRT interconnection leads and instruction manual Note Requires 34000 0 Universal Base Unit and 34008 0 Cooling Boost Module For sub ambient tests down to 5 C a Cryostat 34006 0 is also required Method TAG Closed Cup Tests Non Equilibrium Equilibrium u Flash No Flash Temperature Range Ambient to 93 C 5 C to 93 C with optional cryostat Barometric Correction Automatic Bath Liquid Heating Hot Plate Post Test Cooling Fan assisted or Circulating liquid external cryostat Requires 34008 0 Cooling Boost Module option Post Test Cool down Time 90 C to 50 C Ignitor 40 minutes Fan 3 minutes external cryostat Quick fit coaxial gas jet electric hot wire user selectable Electric hot wire pilot light for gas jet Temperature Probes Class A Platinum Resistance Thermometers Flash Detection Thermocouple
286. d filter plugging point CFPP inserts SUPPLIED WITH mains lead and instruction manual Note Due to the low operating temperature of this bath it is recommended that it is filled with Butyl Glycol BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS S 9 gt 2n m4 zi LU TIL ACCESSORIES CFPP Bath 99005 0 COLD FILTER PLUGGING POINT INSERT comprises test insert two 5 litre pressure equalising vessels three way cock manometer a I and tubing SPECIFICATIONS Wa i Temperature Range 47 C to 100 C ASTMBC IP1C or ASTM5F IP1F or ASTM6C IP2C or ASTM6F IP2F Display Resolution T Note Two thermometers are required for IP 309 oe ET EET Tm HU 1 Temperature Stability 0 02 C UP TONAL Eme an 14030 2 PUMP for details see page 136 Bath apani _ _ mu PT TIAN VERIEICATION amp TRAINING Voltage 110 120V 50 60Hz GALIE d UN VERIFIUATIUIN G ANTIN O 220 240V 50 60Hz 99851 0 VERIFICATION MATERIAL ASTM 06371 IP 309 Gas Oil 5 EN 116 for details see page 150 Powar 99908 0 BIO MULTI TEST VERIFICATION MATERIAL Gas Oil Size HxWxD 55 74 61 for details see page 151 Weight F akg
287. d for the P Gasoline and diesel fuel engine correlation scheme The scheme enables laboratories determining the Derived Cetane Number of diesel fuels by either IP 498 or IP 567 tO e Compare their results against those determined by other users e Compare the Derived Cetane Number DCN to the mean of that Cetane Number CN as determined by IP 41 ASTM D613 in the P Gasoline and diesel fuel engine correlation scheme e Haveasetof secondary working standards with known DCN and CN values that can be used for quality control measurements For further details of membership contact e dcncs energyinst org IFIA EI Petroleum inspector certification programme As part of the inspection industry s continuous improvement efforts the International Federation of Inspection Agencies IFIA has an Inspector certification programme that is operated worldwide Candidates must demonstrate that they have met the IFIA training requirements and pass an examination which is valid for a five year period The programme is monitored by a technical advisory board and overseen by the Energy Institute For further information on examinations excl the Americas please contact IFIA e petcomadminGifia federation org For further information on examinations held in North and South America please contact IFIA AC e ifianac aol com IP international petroleum L gt test methods e Subscription benefits STM Subscribers are alerted by email when
288. d other properties The Seta Oil Content of Wax Apparatus comprises a cooling bath for three filter stick assemblies and a temperature controlled hot air evaporation assembly to hold four 15ml weighing bottles Note Air pump Seta 14030 2 recommended required SETAPLUS EXTENDED WARRANTY SPECIFICATIONS Voltage 110 120V 50 60Hz uu LEBEN 50 60Hz B 21 x 21 x 27cm Evaporation Unit Weight G l S LL CONSUMABLES Oil Content of Wax Apparatus 2 Years 2000 Tests 20480 009 SPRING pack of 20 20850 001 AIR PRESSURE REGULATOR pack of 2 20850 004 WEIGHING BOTTLE 15ml pack of 4 20850 005 FILTER STICK COOLING TUBE pack of 2 pairs 20800 0 ACCESSORIES Oil Content of Wax Apparatus REQUIRED 20850 0 GLASSWARE comprises air pressure regulator filter stick and cooling tube with two assembly springs and four 15ml weighing bottles THERMOMETERS ASTM71F IP72F ASTM71C IP72C OPTIONAL DRY ICE MAKERS for details see page 140 AIR PUMP vacuum and pressure oil free for details see page 136 99100 2 ANALYTICAL BALANCE for details see page 141 45000 0 SETAPLUS EXTENDED 12 MONTH WARRANTY Note Other items which may be required include Pipettes Wire stirrer 14030 2 Centrifuge Equipment OIL TEST CENTRIFUGE 90000 3 SETA OIL TEST CENTRIFUGE ASTM D91 D96 obs D893 D1290 D1796 01966 02273 D2709 02711 04007 D5546 IP 75 obs IP 359 BS 288
289. downloaded to a personal Functions Ambient temperature Leak test computer d i Max Min Tare and audible alarm SUPPLIED WITH dry cell batteries soft carry Display LCD 5 digit 13mm case and instruction manual TERR Power Supply 3 x 1 5V AA Dry cell Size HxWxD 19 x 9x 3 6cm VY Weight 0 CALIBRATION CERTIFICATE UKAS elg 0 99915 0 99910 0 PORTABLE DIGITAL BAROMETER Calibration and cross check of pressure or altimetric measuring instruments Accurate in situ checks for barometric pressure and altitude A portable battery operated precision CDEPIE pressure indicator in waterproof case to IP 54 per 750 to 1150mbar 22 to 34 inHg Pressure is displayed on a high resolution LCD barometric and different units of measurement can be selected to allow reading in pressure or height Accuracy 0 02 Full Scale barometric or altimetric with memory and Units of 24 user selectable peak hold facilities Measurement Aude m An RS232 output allows information to be Husos MaxMin Save Tare Filter downloaded to a personal computer Altitude SUPPLIED WITH dry cell batteries mains Display LCD 6 digit 13mm si se ay west case RS232 Power Supply 3x 1 5V AA Dry cell or cable and instruction manual rechargeable battery Output RS232 via 6 way Lemo connector CALIBRATION CERTIFICATE UKAS Suet Weight _ 0 5kg excluding transit case 99910 0 14
290. drical Weighing Bottle Left Hand Valve Right Hand Valve Silicone Rubber Tube 5 metres Digital Thermometer amp Probe Thermocouple Type K Steam Generator 137 Silicone Rubber Tube Heater Fuel Oil Ageing Bath 86 Fuses pack of 5 Heater Power PCB Air Well Temperature Probe Stirrer Motor Display PCB Overtemperature Cutout Propeller pack of 3 SSAFCON Sampler 82 Pressure Control Valve Quick connect Female Flowmeter Pressure Gauge By Pass Valve High Pressure Hose Seal Replacement Kit Gasket pack of 10 86 104 Index Part Number 16165 2 16165 206 16400 3 15640 001 16400 001 21560 401 16500 0 16500 001 16500 002 16500 003 16500 004 16500 005 16600 2 16620 2 16600 001 16600 002 16600 003 16600 004 16600 005 16600 006 16600 007 16600 008 16600 009 16600 010 16600 011 17400 007 50000 003 50000 004 50000 005 16720 0 16771 0 16720 001 22400 003 16840 0 16720 002 16840 001 22400 003 16860 0 16860 001 16860 002 16860 003 16860 004 16860 005 16860 006 16860 007 16900 5 15155 006 15155 201 15155 204 16155 303 16155 402 16155 405 16155 406 16910 0 16910 001 16910 002 16910 003 16990 2 16990 001 16990 002 16990 003 16990 004 16990 005 17000 2 17190 2 17000 001 17000 002 17000 003 17000 004 17500 0 17000 001 17000 002 17000 003 17000 004 17500 002 17500 003 17500 004 17500 005 17500 006 17500 007 spare Parts
291. e Gravity Balance Loss on Heating Tank Low Tank Medium Tank High Tank Heated Fuel Tank Bitumen Tank Cargo High Aniline Point Low Softening Point High Softening Point Partial Immersion Partial Immersion Petrolatum Melting Point Density Wide Range Relative Density Wide Range Kinematic Viscosity Low Kinematic Viscosity Low Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Oil in Wax Oil in Wax Partial Immersion Partial Immersion Abel Oil Cup Wide Range Abel Oil Cup Wide Range Abel Water Bath Wide Range Abel Water Bath Wide Range Engler Viscosity Solvents Distillation Solvents Distillation Solvents Distillation Solvents Distillation Solvents Distillation Solvents Distillation Solvents Distillation Solvents Distillation Solvents Distillation RANGE 50 15 60 15 58 38 to to to to to to to to to to to to 230 F 121 C 250 F 30 C 21 C 70 F 170 C 30 C 40 C 65 C 120 C 260 C 80 C 170 C 80 C 200 C 300 C 580 F 127 C 102 C 215 F 34 C 29 F 51 4 C 124 5 F 16 6 C 2 5 F 38 6 C 37 5 F 52 6 C 62 5 F 24 6 C 12 5 F 21 C 70 F 400 C 760 F 70 C 160 F 80 C 180 F 55 C 52 C 78 C 102 C 126 C 152 C 255 C 177 C 202 C
292. e Cylinders REQUIRED FOR 22300 2 22490 0 SETA GAUGE ADAPTOR 1 2 inch BSP male to 1 4 inch BSP female For fitting gauge to 22300 2 Main Chamber pack of 2 22330 0 SETA CORROSION RESISTANT SAMPLING CONNECTOR 3ft long one end suits ullage chamber inlet valve connects apparatus to sample PRESSURE GAUGES Select from SETA VAPOUR PRESSURE GAUGES below OPTIONAL 22090 0 SETA COOLING UNIT for LPG with inlet and outlet valves requires solid CO for details see page 118 Typical Cylinder Assembly Gauge and Ullage Chamber supplied separately VAPOUR PRESSURE GAUGES PRESSURE GAUGES SETA VAPOUR PRESSURE GAUGES 22560 0 ASTM 01267 IP 410 BS 2000 Part 410 Pressures up to 3500kPa 500psi Accuracy 1 fsd 150mm dial Mirror scale in kPa and psi A inch BSP fitting Sturdy handle CALIBRATION CERTIFICATE WORKS Arange of Bourdon Tube type pressure gauges with 150mm diameter mirror band dials to eliminate paralax errors while reading The graduations are marked in kPa and psi Ibf in The gauges have a bottom entry inch BSP fitting and a heavy duty stainless steel case with a large carrying handle suitable for lifting a complete pressure vessel assembly from a bath The gauges conform to EN 837 S2 up to 2 500kPa or S3 2 500kPa and above Accuracy Class 1 1 fsd SETA VAPOUR PRESSURE GAUGES Scale Range Division Sub Division kPa psi kPa i kPa psi 0to700 Oto100 50 2 0 5 1750 Oto
293. e even temperature distribution The unit is equipped with over temperature and low liquid level protection devices SUPPLIED WITH mains lead and instruction manual SPECIFICATIONS Max Air Temperature Sample Temp Range Ambient to 75 C Voltage 110 120V 50 60Hz 220 240V 50 60Hz Power ACCESSORIES Air Release Value App REQUIRED 15870 4 CIRCULATING WATER BATH see below 20290 4 AIR PUMP for details see page 136 15860 0 SETA TEST VESSEL glass comprises a jacketed sample tube matched air inlet capillary baffle plate and air outlet tube DIGITAL THERMOMETER AND THERMOCOUPLES for monitoring sample temperature DIGITAL THERMOMETER AND PROBE for measuring air inlet temperature before the test DENSITY BALANCE see below LABORATORY OVEN for warming test sample for details see page 137 OPTIONAL 45000 0 SETAPLUS EXTENDED 12 MONTH WARRANTY 15865 0 16125 0 15880 6 99200 2 SPECIFICATIONS 220 240V 50 60Hz gem Wet m O O CONSUMABLES Density Balance 2 Years 2000 Tests 15880 201 SINKER 10ml glass 15880 202 WIRE 160mm platinum J SOFTWARE INCLUDED 1 Vi CALIBRATION CERTIFICATE WORKS SPECIFICATIONS ve OOO 200 240V 50 60Hz Bee KW ACCESSORIES Water Bath OPTIONAL 15875 0 C amp P TEST JAR HOLDER holds 10 35mm tubes Emulsification Foaming Air Release amp Emulsification ET 96700 0 HERSCHEL EMULSIFIER X3 A
294. e screen Measuring Mode Single or cyclic measurement cycle period 1 99 min Single or cyclic measurement cycle period 1 99 min Particle Count Alarm Low Limit High Limit User defined Printer Lid mounted integral thermal printer Low Limit High Limit User defined Integral compact thermal printer Computer interface RS232C control and data download RS232C control and data download USB data download USB Memory Stick data download Voltage 100 230VAC 50 60Hz max 30W 12VDC for SA1200 0 100 230VAC 50 60Hz max 30W or 24VDC Size HxWxD 37 x 33 x 21cm 24 x 33 x 24cm Weight 129 Particulates Residues amp Composition Particulates FILTRATION TESTS 16160 2 19720 0 19722 0 SSAFCON SAMPLER ASTM D2276 D3830 obs IP 216 791 3008 Filter tests for particle contamination and colour rating of Aviation Fuels Eliminates the exposure of fuel during testing In line test fuel disposal waste requirement Improves operator safety SSAFCON is a unique monitoring system for portable line sampling of aviation turbine fuel to deter
295. e to the low operating temperature of these baths it is cogitou Tina recommended that the compartments are filled with Butyl Glycol Refrigerant Voltage 110 120V 60Hz 220 240V 50Hz Size HxWxD single compartment 15 C to 32 C approx 2hrs from 32 C to 51 C 15 C to 32 C approx 1hr from 32 to 34 C CFC Free First Stage R134a Second Stage R507 CFC Free Single Stage R507 1 8kW 220 240V 50Hz mw 95 x 63 x 63cm SETA CLOUD AND POUR POINT CRYOSTAT Three compartments ambient to 35 C One compartment 35 C to 51 C Independant temperature control Heated anti condensation lid Four 2 litre compartments each independantly temperature controlled Three compartments have a temperature range of ambient to 35 C 0 to 35 1 5 C One low temperature compartment has a range of 35 to 51 C 1 5 C Refrigeration is accomplished by a two stage CFC free system An internal spare canister of R507 refrigerant allows easy recharging of the second stage The lid is electrically heated to prevent the formation of ice and condensation SUPPLIED WITH 16 test jars each comprising graduated glassware thermometer cork insulating gasket and disk a compartment thermometer and instruction manual f BIO FUEL TESTING ID CALIBRATION amp VERIFICATIO
296. eat transfer characteristics and has good correlation with ASTM D1740 Luminometer number Comprises a tripod stand lamp body and chimney The measuring scale is viewed through a curved glass window on the front of the instrument A mirror 10450 0 can be attached to the chimney to aid smoke detection SUPPLIED WITH candle assembly and certified wick ACCESSORIES Smoke Point Apparatus REQUIRED CONSUMABLES Smoke Point App 2 Years 2000 Tests Qty 10400 004 WICK TUBE 1 CALIBRATION amp VERIFICATION MATERIALS 10400 0 with 10450 0 Mirror Supplied separately 10450 0 SETA MIRROR for fixing to chimney to detect first indication of smoke OPTIONAL 10410 0 SETA WICK TRIMMER inserts wick and automatically sets to correct length 10410 0 10425 0 WICK EXTRACTION APPARATUS for details see below 10430 0 SETA INSTRUMENT CASE for lamp assembly stand and five candles CALIBRATION VERIFICATION amp TRAINING MULTI TEST VERIFICATION MATERIAL ASTM D1322 Kerosine for details see page 150 99850 0 WICK EXTRACTION APPARATUS ASTM D1322 IP 57 Simple and safe to use In accordance with test method The test methods require that wicks used in the smoke point apparatus are extracted ina 50 50 mix of toluene and anhydrous methanol The 14025 0 comprises a 60ml soxhlet extractor condenser 500ml glass flask flask heater stand and clamp ACCESSORIES Wick Extraction Apparatu
297. eceiver pack of 3 11867 0 DIGITAL THERMOMETER for condenser 11868 0 HEAT SHIELD SETASTILL ASTM D447 only 97005 0 DIGISTILL for details see page 30 99300 2 MINI LOW TEMPERATURE BATH CIRCULATOR to provide chilled water for condenser for details see page 139 99910 0 PORTABLE DIGITAL BAROMETER 750 to 1150 mbar absolute for details see page 145 CALIBRATION VERIFICATION amp TRAINING 99850 0 MULTI TEST VERIFICATION MATERIAL Kerosine for details see page 150 99851 0 VERIFICATION MATERIAL Gas Oil for details see page 151 99854 0 VERIFICATION MATERIAL Motor Gasoline for details see page 151 99908 0 BIO MULTI TEST VERIFICATION MATERIAL Gas Oil for details see page 151 11860 3 and Accessories SPECIFICATIONS Distillation Range Ambient to 400 C Voltage Range 110 120V or 220 240V 50 60Hz switchable Power 1000W maximum Condenser Volume 7 2 litre Size HxWxD 47 x 37 x 25cm Condenser Unit 47 x 21 x 21cm Distillation Unit Weight 12kg total Heference Methods Distillation 11800 0 11810 0 T 4 44 0 1932 564391 Fr 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk SETA DISTILLATION UNIT ASTM 086 0216 obs D447 obs D850 D1078 E133 IP 123 IP 191 I
298. endeavour to advise the customer and reserve the right to supply goods to the specification and or design current at the date of despatch Goods and services are supplied under our ISO 9001 Quality accreditation 3 Quotations acceptance and delivery Prices and delivery details are correct at the time of quotation and may be subject to amendment or to confirmation at the time of receipt of order Vo liability is accepted for any amendment Whilst every effort is made to meet delivery dates these are estimates only No liability is accepted for delays and time is not of the essence After acceptance of a firm order we are under no obligation to accept amendments or cancellations but will at all times endeavour to meet customers revised wishes Details of our minimum order value are stated in our current price list 4 Prices packing and freight Unless otherwise specified by us all prices are ex works and packed suitable for airfreight Value Added Tax will be charged where applicable The date of invoicing is the date when goods leave our factory or when the customer is notified that they are ready for collection If goods are ready for delivery and collection as agreed but goods are not called forward after 14 days notification they may be subject to demurrage charges We are pleased to quote costs for freight insurance certification and documentation Transport of hazardous materials may involve additional cost 5 Insuran
299. enetration tip Penetration is shown on a 150mm dial graduated 400 x 0 1mm increments equipped with a slipping clutch pointer The machined aluminium base is fitted with a flexible light with dimmer switch and a spirit level SUPPLIED WITH 47 5g plunger 50g and 100g plunger weights mains lead and instruction manual 17190 2 Cone and container supplied separately SPECIFICATIONS Penetration Range 0 to 400 Pen 40mm Penetration Time 5 8 10 12 30 60 seconds selectable Retention Release Automatic Display 150mm dial 400 x 0 1mm increments Voltage 110 120V or 220 240V 50 60Hz switchable Power 45W Size HxWxD 67 x 30 x 33cm Weight 9kg 7 CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE Penetrometers Penetration 17000 SERIES PENETROMETERS SERIES PENETROMETERS 17000 2 SETA UNIVERSAL PENETROMETER Penetration range 0 to 400 Pen 40mm A manual penetrometer with a range of 0 to 40mm 400 Pen The head is fitted with a two speed elevating mechanism for quick and precise positioning of the penetration tip Penetration is shown on a 150mm dial graduated 400 x 0 1mm increments equipped with a slipping clutch pointer The machined aluminium base has an integral spirit level SUPPLIED WITH 47 5g plunger 50g and 100
300. epair Kit Sulphur Lamp Method Unit Frame Control Valve Kilner Jar Trap 500ml Synthetic Air Unit Thermometer Dial Type Heater Element Flowmeter 150 1500 I hr carbon dioxide Flowmeter 60 600 I hr oxygen Page 98 136 97 97 Sampling Cylinder 100ml Single Valve 119 123 Straight Through Valve Nitrile Seal for 1 8 inch BSP pack of 5 Nitrile Seal for 1 4 inch BSP pack of 5 Glassware Splash Bulb spray trap pack of 2 Flask pack of 3 Standard Burner pack of 3 Chimney Absorber Pressure Regulator Scrubber Levelling Bulb reservoir pack of 3 Spring pack of 20 Sampling Cylinder 50m Single Valve Straight Through Valve Nitrile Seal for 1 8 inch BSP pack of 5 Nitrile Seal for 1 4 inch BSP pack of 5 Oil Content of Wax Apparatus Temperature Controller Thermocouple Spring pack of 20 Air Pressure Regulator pack of 2 Weighing Bottle 15ml pack of 4 Filter Stick Cooling Tube pack of 2 pairs Grease Separation Apparatus Separation Cup Weight Grease Separation Apparatus Cone Grease Separation Apparatus Control Valve for Framework Sieve Beaker 25ml pack of 5 Pressure Bleeding Test Cell Type B Sieve Beaker 25ml pack of 5 Asphaltenes Apparatus Allihn Condenser pack of 2 Extractor pack of 2 Glass Stoppers pack of 5 Stirring Rod pack of 10 Filter Funnel pack of 2 Evaporation Dish pack of 5 Extraction Apparatus Thimble pack of 5 Erlenmeyer Flask 1 litre
301. eric pressure escape of vapour into the PI laboratory environment is prevented Size HxWxD TERES Weight 2kg 90300 2 SETA BLOCK HEATER A processor controlled heater designed to be used in conjunction with a 90301 0 Block for heating centrifuge tubes The heater has a temperature range of 15 to 130 C 90301 0 BLOCK aluminium holds four 90040 0 or The heater is equipped with a 1 to 9999 minute aA countdown timer with buzzer a temperature deviation alarm that can be set from 0 5 to 10 C allowable deviation an external temperature ACCESSORIES Block Heater Dry heating for samples e 15 C to 130 C tube capacity 9999 minute timer Temp range 15 C to 130 C probe socket and a delay start stop feature allowing the heater to be turned on or off after Stability 0 1 C a predetermined time interval Timer Range 1 to 9999 mins The heater can be calibrated by the user over can Buen 200W 110 a wide temperature range 300W Q240V SUPPLIED WITH block extractor tool mains Voltage 110 120V 50 60Hz lead and instruction manual BEEN 220 240V 50 60Hz 90300 2 with 90301 0 Block and 90060 0 Tube Note Block 90301 0 required see accessories Size HxWxD 10 x 20 x 28cm Weight 3kg 44 0 1932 564391 F 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk 109 Cetane 92000 3 Cetane Number dvanced ngine echnology Ltd IGNITION QU
302. erm temperature stability without routine maintenance or re calibration The separate Oxflo control unit includes a gas inlet pressure regulator pressure gauge and six precision flowmeters calibrated for oxygen at 3 litres hour 21 C and 0 4bar pressure Safety features include low level liquid protection and over temperature cut outs SUPPLIED WITH Oxflo control unit six flow meters mains leads and instruction manual Note Glassware and catalysts must be ordered separately SETA OXIDATION BATH WITH OXFLO CONTROLLER position oil bath Unique light tight when closed viewing window All details are similar to 16900 5 above except that the bath has a unique light tight when closed viewing window SUPPLIED WITH Oxflo control unit six flow meters mains leads and instruction manual Note Glassware and catalysts must be ordered separately ASTM D943 D2112 D2272 D2440 D4310 D5846 IP 229 IP 306 IP 307 IP 331 obs IP 335 BS 148 ISO 4263 DIN 51 587 NF T60 150 IEC 61125 A B amp C VY CONFORMANCE CERTIFICATE PRE FORMED 0115 16921 0 COPPER STEEL pack of 6 16931 0 COPPER pack of 6 16791 0 COPPER pack of 6 16919 0 COPPER STEEL pack of 6 STANDARD WIRE LENGTHS 16780 0 IRON 15m 16790 0 COPPER 15m 16920 0 STEEL 3m pack of 6 16930 0 COPPER 3m pack of 6 LIQUID 16932 0 ASTM CATALYST B METAL NAPHENATE MIXTURE for ASTM D4742 sufficient for 35 tests 16900 5 Glassware
303. es 3 Open Cup Tester 16 Silicone Rubber Tube 4 metres Syringe 2ml Heat Sink Compound Syringe 4ml Gas Tank Front Panel Assembly Over Temperature Cut Out Wiring Set Rubber Feet set Service Screw Set Controller PCB Closed Cup Sample Block Fuse 2A pack of 10 Series 3 Plus Closed Cup Tester 13 Silicone Rubber Tube 4 metres Sample Well Seal Ring Viton pack of 5 Syringe 2ml Heat Sink Compound Flash Detector Assembly Sample Well Seal Ring Silicone pack of 5 Syringe 4ml Gas Tank Closed Cup Sample Block Front Panel Assembly Over Temperature Cut Out Wiring Set Rubber Feet set Service Screw Set Locking Post for Lid Controller PCB Lid amp Shutter Assembly Fuse 2A pack of 10 Series 3 Active Cool 12 Silicone Rubber Tube 4 metres Sample Well Seal Ring Viton pack of 5 Syringe 2ml Heat Sink Compound Flash Detector Assembly Sample Well Seal Ring Silicone pack of 5 Syringe 4ml Gas Tank Front Panel Assembly Rubber Feet set Service Screw Set Locking Post for Lid Controller PCB Closed Cup Sample Block Over Temperature Cut Out Wiring Set Lid amp Shutter Assembly Fuse 2A pack of 10 Series 3 Active Cool Corrosion Resisting 12 Silicone Rubber Tube 4 metres Sample Well Seal Ring Viton pack of 5 Part Number 13740 009 13740 017 13740 425 13770 004 13770 311 30000 002 30000 004 30000 007 30000 008 30000 009 33200 203 33200 204 33250 201 33250 202 70
304. ethods unlike the expansion technologies that rely on moving pistons All functions are accessed via a two button keypad and a rotary control The digital display leads the operator through the test sequence displays the instrument status and the test results An audible prompt is sounded when an action is required from the operator A sample is injected through a septum into a fixed volume chamber that is maintained at 37 8 C 0 1 C The vapour to liquid ratio is 4 1 The pressure is automatically measured at one minute intervals until three readings are within 0 1 kPa which determines the end of the test Results can be displayed as total pressure Ptot dry vapour pressure equivalent DVPE EPA requirements or Reid crude using pre programmed correlation equations and may be printed via the integral RS232 port and optional 81002 0 printer A facility is included to allow two part tests Pabs to be conducted at 37 8 C All valve operations are automated including sample draining and chamber venting and purging The valves utilise solvent resistant Kalrez seals Calibration of temperature and pressure is automated and simple to carry out SUPPLIED WITH Septum holder waste container mains lead and instruction manual SPECIFICATIONS Test Temperature 38 7 C 100 F 0 1 C Test Pressure Range 0 to 200kPa 0 5 0 to 29psi 0 1 51 Pressure Resolution 0 1kPa 0 1psi Display Units of P
305. ezing protection SUPPLIED WITH mains lead and instruction manual Note Supplied excluding fittings CRYOSTAT Temperature range 20 to 100 C Booster Pump for 9l min flow A small footprint low temperature bath with booster pump for increased flow of chilled water for external cooling applications Comprises a 99300 2 bath with a vertical turbine pump SUPPLIED WITH mains lead and instruction manual Note Supplied excluding fittings Temperature range 47 to 100 C Temperature stability 0 1 C Bath capacity 12 litres Flow rate 17 litres min maximum Pressure 1 4 5psi Power 24KW Voltage 110 120V 50 60Hz 220 240V 50 60Hz Size HxWxD 55x74x61cm Weight Si RI SPECIFICATIONS Temperature range m 20 to 1 00 Temperature stability 0 1 C Balticapaciti I 5 litres Flow rate 17 litres min maximum Pressure 31kPa 4 5psi 1 8KW maximum heat Voltage 110 120V 50 60Hz 220 240V 50 60Hz Size HxWxD 41 x 41 x 23cm Weight 25kg SPECIFICATIONS Temperature range I 20 to 100 C Temperature stability 0 1 C Bath capacity eines Flow rate 9 litres min 100kPa Pressure 100kPa 1
306. f 4 90005 2 ADAPTOR pack of 4 90010 0 SETAFUGE HAZARD REDUCTION SYSTEM 90011 0 TUBE pack of 6 90012 0 TUBE pack of 6 90014 0 LOW TROLLEY 90015 0 HIGH TROLLEY 90016 0 TRANSFORMER 90040 0 TUBE pack of 6 90041 2 STOPPERS pack of 50 90050 0 TUBE pack of 6 90060 0 TUBE pack of 6 90200 4 WATER BATH 90202 2 RACK 90203 2 RACK 90204 2 RACK 90300 2 BLOCK HEATER 90301 0 BLOCK 91600 3 MFT MULTI FILTRATION TESTER 91615 0 START UP KIT 91616 0 START UP KIT 91635 0 START UP KIT 91640 0 HOLDER 91645 0 MAINTENANCE KIT 91650 0 CARRY CASE 91660 0 MEASURING CYLINDER 91662 0 PRESSURE CALIBRATOR 92000 3 IGNITION QUALITY TESTER 92002 0 SERVICE SPARES KIT 92007 3 START UP KIT 92008 6 CALIBRATION KIT 92009 2 EXTRACTION FAN SYSTEM 92010 2 POWER SUPPLY KIT 92020 3 GAS REGULATOR KIT 93531 7 CLOUD AND POUR POINT CRYOSTAT 93700 2 LABORATORY REFRIGERATOR 94000 2 COLD FILTER PLUGGING POINT CFPP BATH Page 33 49 155 33 49 155 33 49 155 33 49 155 33 49 155 33 35 33 35 36 37 39 111 111 111 50 22 23 140 52 Part Number Page 94000 2 LOW TEMPERATURE BATH CIRCULATOR 139 94100 3 COMPACT CLOUD AND POUR POINT CRYOSTAT 50 94110 0 TROLLEY 51 94630 0 BATH OIL 5 litres 33 35 138 94631 0 SILICONE BATH OIL 2 litres 33 35 138 94632 0 SILICONE BATH OIL 20 litres 36 37 46 64 68 76 105 138 94633 0 BATH OIL 20 litres 36 37 46 68 76 78 105 138 94634 0 BATH OIL 5
307. fication UKAS to ISO 17025 UKAS to ISO 17025 UKAS to ISO 17025 UKAS to ISO 17025 Seta Part Number Certified Value nom 15370 0 0 5 15371 0 15372 0 15373 0 Certification Certified Value nom 10 UKAS to ISO 17025 0 UKAS to ISO 17025 12 UKAS to ISO 17025 25 UKAS to ISO 17025 For quick and simple conformance checks on Seta Lovibond High Precision Colorimeters Each filter set comprises coloured glasses representing a spread of colours from the scale and a storage case CONFORMANCE CERTIFICATE ISO 9001 OR wg CALIBRATION CERTIFICATE UKAS SEE TABLE Certification 0 5 3 5 5 0 Colour No Of Filters ASTM Colour 3 Seta Part Number 15302 0 only suitable for 15320 2 Seta Lovibond Colour Colorimeter Saybolt Colour 8 0 0 10 18 25 T 44 0 1932 564391 LF 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk Conductivity Meter amp Oil Testers Conductivity amp Insulation CONDUCTIVITY METER METER 99708 0 HAND HELD CONDUCTIVITY METER ASTM D2624 IP 274 Higher Accuracy AC Measurement Conductivity and temperature output capability High Accuracy 2 of reading Stores up to 10 Data Locations User can input Location Names USB interface for ease of data transfer to user Fully Temperature Compensated Measurement Built in Long Life Lithium lon Rechargeable Battery Windows Data Handling Software Internal Real Time Da
308. filters amp exit tubing OR START UP KIT PROCEDURE C comprises bum encapsulated filters amp exit tubing SETALERT REMOTE PAGING SYSTEM PRINTER HOLDER for 25mm filters MAINTENANCE KIT all necessary O rings and seals two cleaning wires a damper key and replacement fuse CARRY CASE DIGITAL STOPWATCH hand held 0 1s resolution for details see page 141 MEASURING CYLINDER PRESSURE CALIBRATOR 76mm pressure gauge CALIBRATION CERTIFICATE WORKS PRECISION DIGITAL THERMOMETER for details see page 130 PRINTER 20 ee ann 1 EIETERSAA 100 1 ENCAPSULATED FILTERS B 1 6um pack 0 100 1 ENCAPSULATED FILTERS 5um pack of100 1 anhope seta co uk w www stanhope Particulates Residues amp Composition Residues CARBON amp ASH RESIDUE 97400 2 MICRO CARBON RESIDUE TESTER ASTM D4530 IP 398 BS 2000 Part 398 ISO 10370 Carbon residue range 0 1 to 30 0 m m 12 sample capacity Automatic temperature ramp and gas control Equivalent to ASTM D189 IP 13 Temperature range ambient to 500 C An automatic airtight furnace that is pre programmed to run tests to determine the Micro Conradson Carbon residue of petroleum products The digitally controlled furnace has a temperature range of ambient to 500 C Temperature flow and pressure values are automatically controlled and values are displayed on the
309. g plunger weights and instruction manual CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE S SPECIFICATIONS Display 150mm dial 400 x 0 1mm increments wm NN 17000 2 Cone and container supplied separately ACCESSORIES 17000 Series Penetrometers REQUIRED PENETRATION CONES NEEDLES PLUNGERS and KITS Either refer to the table to select the individual items required for a test method or select an appropriate Penetration Kit OPTIONAL 18580 0 ASTM 05 IP 49 STARTER KIT comprises pack of 3 needles 10 bitumen containers and a transfer dish e e 17120 0 SETA MIRROR AND CLAMP assists in positioning penetration devices over the sample surface e 18200 5 WATER BATH for details see page 61 ee e 17500 0 17190 3 17000 2 22750 2 DIGITAL STOPWATCH for details see page 141 CALIBRATION VERIFICATION amp TRAINING 17150 0 PENETROMETER CALIBRATION KIT with UKAS Certification for details see page 149 99856 0 MULTI TEST VERIFICATION MATERIAL IP49 Bitumen for details see page 151 ITEMS REQUIRED FOR EACH TEST ASTM D5 ASTM 0217 ASTM D937 ASTM 01321 ASTM D1403 19140 0 or 18000 0 18000 0 18490 0 Sample Container 18470 0 or 18530 0 see Grease Workers 18120 0 18480 0 amp 18481 0 see Grease Workers Transfer Dish 18550 0 Grease Worker ASTM D1831 17910 0 17950 0 or 18060 0 17380 0 see Grease Workers Needles Cones amp
310. ge 141 CALIBRATION VERIFICATION amp TRAINING 99850 0 MULTI TEST VERIFICATION MATERIAL ASTM 0611 Kerosine for details see page 150 Particulates Residues amp Composition Composition SALT IN CRUDE ccc 99700 4 14300 3 SALT IN CRUDE ANALYSER ASTM D3230 IP 265 Switch allowing ASTM or IP mode to be selected Automatic salt concentration calculation Pre calibrated for immediate use Verification mode RS232 interface Software supplied Battery or mains voltage operation Weatherproof A portable instrument that measures conductivity and temperature of crude oils The instrument is pre calibrated and automatically calculates the salt concentration in g m or pounds per thousand barrels ptb Ib 1000bbl Measurements can be displayed or downloaded to a PC Calibration mode allowing 3 point calibration of sensor In this way the sensor can be replaced and or recalibrated by the user if it becomes damaged SUPPLIED WITH beaker holder stand carry case mains adaptor software RS232 cable and instruction manual SOFTWARE SUPPLIED NT SY EJA J TECHNICAL DATASHEETS AVAILABLE SETA DUAL EXTRACTION APPARATUS ASTM D2547 obs IP 77 IP 182 IP 248 BS 2000 Part 182 BS 5290 EN 13 obs ISO 2083 obs DIN 51 576 NF M07 014 NF M07 023 NF T60 133 Supports two sets of glassware Seta 14310 0 Two independent heater controllers Cooling water control valve Dual Extraction
311. gital temperature controller is housed in a separate unit The instrument is protected by an overtemperature cut out An automated density balance Seta 15880 6 is available as an accessory SUPPLIED WITH connection tubing digital temperature control unit mains lead and instruction manual Note Requires connection to a suitable air supply and a Density Balance SETAPLUS EXTENDED WARRANTY AVAILABLE ASTM 03427 IP 313 BS 2000 Part 313 DIN 51 381 ISO 9120 NF T60 149 15880 6 CIRCULATING WATER BATH 15870 4 Optimised for use with Seta Air Release Value Apparatus Automatic density calculation e 0 001g ml resolution The Seta Density Balance comprises an electronic balance with a 10ml glass sinker platinum wire and Seta ARV software The software monitors the output of the balance calculates the density of the sample prior to and during the test and determines the time taken for the sample to reach the target density SUPPLIED WITH Seta ARV software platinum wire glass sinker stand connecting cable mains lead and instruction manual Note Requires connection to a compatible personal computer not supplied Temp range ambient 5 C to 120 C Integral stirrer Q Over temperature and low liquid level protection e 12litre bath A compact thermostatic bath digitally controlled to an accuracy of 0 1 C across a temperature range of ambient 5 C to 120 C with a stirrer to ensur
312. hydrometers and thermometers are PTIONAI available as accessories 4500 0 SETAPLUS EXTENDED 12 MONTH WARRANTY SUPPLIED WITH instruction sheet cam Tm FAD FARI r 1 g nui I UN LAUT TL L0 Seta No 01657 obs IP 59 obs IP 235 150 3993 PRESSURE CERTIFICATE WORKS 22580 2 e e e 22680 0 e e e 22690 0 e o e SETAPLUS EXTENDED WARRANTY AVAILABLE 2730 0 e 22720 0 22705 0 22710 0 e SPECIFICATIONS Max Working Pressure 1400kPa 200psi 22100 0 Temperature Range 20 to 60 C Pressure Gauge Size HxWxD 62 x 20 x 20cm supplied separately Weight 4 2kg 22101 4 with 22100 0 supplied separately 22100 002 GASKET m TNNT TU TUTTI 1 RELATIVE DENSITY lll 97300 0 SCHILLING EFFUSIOMETER SPECIFICATIONS Size HxWxD 62x 30x 30cm IP 59 Method C obs Weight akg An instrument providing a rapid and convenient method for determining the density of a gas relative to air Ce Schilling Effusiometer Based on the assumption that the times taken by equal volumes of gases under the same temperature 97310 0 TRANSIT CASE lightweight with foam inserts to receive e 97300 0 1 and pressure to flow through a small orifice are Effusiometer thermometer and spares a proportional to the square roots of the densities of 97320 0 SETA METAL STAND with ca
313. ids detection of break thread 22750 2 DIGITAL STOPWATCH for details see page 141 THERMOMETERS ASTM90C or 91C 17730 0 DIAL THERMOMETER bimetal type 30 to 60 C for Seta Zahn flow cups 48 Viscosity Viscosity Standards amp Reference Materials VISCOSITY STANDARDS Full compliance to ASTM IP amp other method protocols Manufactured under ISO 17025 quality standards UKAS Certified Supplied in 500 ml containers Tamper evident packaging for security and proof of integrity Valid for 2 years Viscosity standards supplied by Seta are exactly equivalent to and interchangeable with other recognised viscosity standards that adopt the reference numbers shown in the product table listed below as specified in many international test methods and often referred to for calibration requirements Seta supplied viscosity standards are manufactured in full compliance with ASTM D2162 Note The viscosity values in the following table are approximate and are for guidance in choosing the appropriate standard only The actual values will be indicated on the container CALIBRATION CERTIFICATE UKAS GENERAL PURPOSE VISCOSITY STANDARDS KINEMATIC VISCOSITY mm S cSt Standard Seta 20 00 C 25 00 C 37 78 C 40 00 C 50 00 C 60 00 C Ref No PartNo 00 77 00 F 100 00 F 10400 12200 140 00 3 99784 0 46 4 1 3 1 2 9 24 2 1 D5 99830 0 7 1 6 1 4 1 3 3 S6 99785 0 10 8 8 6 5 7 4 5 3 6 D10 99831 0 15
314. iflash Abel Module 5 Sample PRT Hexagonal Key Set Abel PRT IP 70 Equilibrium PRT ISO 1516 amp 1523 Ignitor Lid amp Shutter Assembly Sample Cup Flash Detector Printer Paper pack of 20 Multiflash Cleveland Open Cup Module 6 Ignitor lonisation Ring Sample PRT Hotplate PRT Fire Sensor Probe Test Cup Insulator Ring Probe Block Hexagonal Key Set Sweep Arm Height Gauge Electric Cleveland Height Gauge Sweep Arm Height Gauge Gas Hussami Filter Papers pack of 50 Printer Paper pack of 20 Multiflash Tag Module 7 Flash Detector Hexagonal Key Set Sample PRT Bath PRT Ignitor Lid amp Shutter Assembly Overflow Vessel Printer Paper pack of 20 Multiflash Small Scale Setaflash Module 8 Sample Well Seal Ring Viton pack of 5 Sample Well Seal Ring Silicone pack of 5 Hexagonal Key Set Ignitor Flash Detector Lid amp Shutter Assembly Printer Paper pack of 20 Seta Vent 19 Filter Assembly Setavap Analyser 20 Heatsink Compound Mains Lead Index Part Number 22420 005 22420 006 22420 014 40000 002 40000 004 40000 007 80000 001 80000 002 80000 003 80000 004 80000 005 80000 006 80000 007 80000 008 80000 009 80000 010 80000 011 80000 012 80000 013 80000 014 80000 015 80000 016 80000 017 80000 018 80000 019 80000 020 80000 021 80000 022 80000 023 80000 024 80000 025 80009 0 81003 001 81003 002 81000 2 22420 033 81000 001 81000 002 81000 003
315. ining the total sulfur in liquid petroleum products when in concentrations greater than 0 002 20ppm by weight The 20410 0 allows simultaneous analysis of up to five samples The framework that supports the glassware incorporates the air manifold and the suction manifold all needle valves and the pressure differential control valve A complete set of glassware for five simultaneous tests is available as an accessory Seta 20490 0 SUPPLIED WITH instruction manual 20410 0 Glassware supplied separately ACCESSORIES Sulfur Lamp Method Unit Size HxWxD 48x 90 x 46cm Weight 15kg Select from the table ITEMS REQUIRED FOR EACH TEST mn 14010 4 VOLUME METER for measuirng air volume M UI TEqUE ence a tier 15630 0 SETA CHARGING LEAD high pressure for connecting sampling cylinder to is s eL LE source One metre length Fitted with Hansen high pressure quick connect Seta No D1266 D1072 D2784 D2384 IP107 couplings male one end female the other 18550 0 SETA TRANSFER DISH copper for use with 20540 3 regulating valve pack 15630 0 of 2 18550 0 20290 4 AIR PUMP for details see page 136 20290 4 e e e e 20460 2 SYNTHETIC AIR UNIT supplies a mixture of 70 CO and 30 O odd Voltage 110 120V 50 60Hz 20470 3 e 220 240V 50 60Hz 20490 0 e Power 460W Size HxWxD 47 x 44 x 26cm a 9 s Weight 17 5kg rn 20470
316. ion For transparent liquids 0 01 11619 02 requiring 13 to 40ml of sample 0 03 11619 03 0 1 0 3 1 0 3 0 10 0 11619 04 11619 05 11619 06 11619 07 11619 08 IQ gt 11637 CALIBRATED U TUBE REVERSE FLOW VISCOMETERS 0 003 11637 01 BS 188 Type BS IP RF 0 01 11637 02 With constant and certificate of calibration For transparent and opaque 0 03 11637 03 liquids requiring a sample of 12 to 25ml 11637 04 11637 05 11637 06 11637 07 11637 08 11637 09 11637 10 11637 11 0 3 1 0 3 0 10 0 30 0 20 000 to 100 000 100 0 60 000 to 300 000 300 0 cO O UO 11625 CALIBRATED SUSPENDED LEVEL VISCOMETERS SUSPENDED LEVEL VISCOMETERS Viscosity Range mm s Nominal Constant Size Code Seta Part BS 188 Type BS IP SL I 0 01 1 11625 01 0 03 1A 11625 02 With constant and certificate of calibration For transparent liquids 0 1 2 11625 03 requiring 22 to 40ml of sample 0 3 2A 11625 04 1 0 3 11625 05 3 0 3A 11625 06 10 0 4 11625 07 30 0 4A 11625 08 100 0 5 11625 09 11628 CALIBRATED SUSPENDED LEVEL VISCOMETERS SHORTENED FORM Size Code SEL 1103 0 003 11628 02 BS 188 Type BS IP SL S 0 01 11628 03 0 03 11628 04 With constant and certificate of calibration For transparent liquids 0 1 11628 05 11628 06 11628 07 11628 08 11628 09 requiring approximately 10ml of sample 0 3 1 0 3 0 10 0 co C CA
317. ion pump with an insulated sample trap connecting tubes pick up tube and stopper k 26000 0 Flash Point Smoke Point amp Sustained Burning Small Scale Flash Point SETAFLASH SMALL SCALE OPEN CUP FLASH POINT Test methods specified under UN and IATA Dangerous Goods Regulations and others determine whether a liquid sustains combustion when heated and exposed to a flame under specified test conditions Certain substances classified as Flammable by Closed Cup Flash Point Testing may be reclassified as non flammable by combustibility testing This has significant potential cost implications for the packaging storage and shipping of many substances 31000 0 SETAFLASH SERIES OPEN CUP TESTER ASTM D4206 BS 3900 Part A11 ISO 9038 UN Class 3 Test L 2 CFR 49 173 120 IATA Dangerous Goods Regs Section 3 3 5 Health and Safety Comm Carriage of Dangerous Goods by Road amp Rail App B Flash point test in less than 2 minutes Small sample size 2ml Ambient to 300 C temperature range Audible and on screen prompts Portable operation Simple calibration The Setaflash 31000 0 is a simple to use and reliable open cup tester for flash no flash finite determinations or sustained combustion tests within a range of ambient to 300 C The manually operated flame sweeping arm is supplied from an integral gas tank that is filled using a standard butane lighter refill cartridge The flash or sustained combustion chara
318. ions of use are affecting the accuracy of the hydrometer Note To avoid false accuracy a hydrometer should always be checked to ensure that the paper scale has not moved The datum line a horizontal line shown above the graduations on the paper scale must exactly align with a corresponding etch line marked into the glass stem CONFORMANCE CERTIFICATE OPTIONAL CALIBRATION CERTIFICATE UKAS TEMPERATURE THERMOMETERS Seta offer a large range of liquid in glass and digital thermometers suitable for use in test methods and for calibration purposes Please refer to Section 20 Temperature amp Fluid Density on pages 124 135 E The temperature corrections for mercury in glass thermometers may change over a period of time and as a general guide it is considered desirable to re test thermometers at intervals not exceeding 5 years Kinematic Viscosity thermometers and other types of a similar accuracy should be re tested more frequently Ll Note To avoid false accuracy a thermometer should always be inspected before use to ensure that no gas has been trapped in the bulb or contraction chamber and that there are no globules of wass separated mercury in the bore or expansion chamber above the column E CONFORMANCE CERTIFICATE OPTIONAL CALIBRATION CERTIFICATE UKAS Operating range 33 to 300 C SPECIFICATIONS Multiple diameter probe wells Range I 33 to 300 C in 0 1 C increments
319. irculator 139 Fuse Heater Power Board Probe Motor Dsiplay Board Automatic Oil Tester 60kV 115 Automatic Oil Tester 80kV 115 Automatic Oil Tester 100kV 115 13mm Spherical Electrodes pair 36mm Mushroom Electrodes pair 1 inch Cylindrical Electrodes pair 116 135 Salt in Crude Analyser 94 Glass Beaker pack of 10 Replacement probe amp calibration Part Number SA1000 0 SA1000 001 SA1000 002 SA1000 003 SA1000 004 SA1000 010 SA1000 011 SA1000 014 SA1000 015 SA1000 016 SA1000 018 SA1000 019 SA1000 020 SA1000 021 SA1030 0 SA1200 0 SA1000 001 SA1000 002 SA1000 004 SA1000 010 SA1000 011 SA1000 012 SA1000 013 SA1000 014 SA1000 015 SA1000 016 SA1000 017 SA1000 018 SA1000 019 SA1000 020 SA1000 021 SA1030 0 SA4000 0 SA4000 001 SA4000 002 SA4000 003 SA4000 004 SA4000 005 SA4000 006 SA4000 007 SA4000 008 SA4000 009 SA4000 010 SA4001 001 SA4001 002 SA4004 001 SA4005 0 SA4006 0 SA4010 0 SA5000 0 SA5000 001 SA5000 002 SA5000 003 SA5000 004 SA5000 005 SA5000 006 SA5004 010 SA5004 050 SA5004 100 SA5005 010 SA5005 050 SA5005 100 SA5007 010 Index Page SefaAnaluftics AvCount Particle Counter 80 Sample Probe Sample Tube and Stopper Printer Paper pack of 10 rolls AvCount Exit Tube Assembly Particle Sensor 45 50 Double Pump Exchange Cell 45 50 Exchange Double Pump Printer Micron Filter Tube Assembly Hose Coupling 4 6mm Hose Coupling 2 5 4mm Hose Coup
320. istillation 2 to 52 C 0 2 C 100 395 5F 1F Cloud and Pour 36 to 120 F 2 F 108 230 38C 78C Solvents Distillation 24 to 78 C 0 2 C 100 395 6C 2C Low Cloud and Pour 80 to 20 C 1 C 76 230 39C 79C Solvents Distillation 48 to 102 C 0 2 C 100 395 6F 2F Low Cloud and Pour 112 to 70 F 2 F 76 230 7C 5C Low Distillation 2 to 300 C 1 total 385 40C 80C Solvents Distillation 72 to 126 C 0 2 C 100 395 7F Low Distillation 30 to 580 F 2 F total 385 4C 81C Solvents Distillation 98 to 152 C 0 2 C 100 395 8C 6C High Distillation 2 to 400 C 1 total 385 42C 82C Solvents Distillation 95 to 255 C 0 5 C 100 395 8F High Distillation 30 to 760 F 2 F total 385 43C 65 Kinematic Viscosity 51 6 to 34 C 0 1 C total 420 9C 156 Low Pensky Martens 5 to 110 0 5 57 290 65F Kinematic Viscosity 61 to 29 F 0 2 F total 420 JE 15F Low Pensky Martens 20 to 230 F 1 F 57 290 44C 29 Kinematic Viscosity 18 606 to 21 4 C 0 05 C total 305 10C 16C High Pensky Martens 90 to 370 C 2 C 57 290 44F 29 Kinematic Viscosity 66 5 to 71 5 F 0 1 F total 305 10F 16F High Pensky Martens 200 to 700 F 5 F 57 290 45C 30 Kinematic Viscosity 23 6 to 264 C 0 05 C total 305 45F 30 Kinematic Viscosity 74 5 to 79 5 F 0 1 F total 305 11C 28C Cleveland Open Flash 6 to 4400 2 25 310 46C 66C Kinematic Viscosity 48 6 to 51 4 C 0 05 C tot
321. ith outlet is mounted beneath the heaters The condenser unit is attached to the distillation unit and may be used with either a static fill of coolant or a laboratory cooling supply Housed within the condenser unit is a thermally insulated stainless steel coolant tank fitted with a permanently installed condenser tube A drain tap and an overflow outlet are mounted on the rear of the unit SUPPLIED WITH mains lead and instruction manual CALIBRATION amp VERIFICATION MATERIALS TECHNICAL DATASHEETS AVAILABLE DO ACCESSORIES Setastill REQUIRED DISTILLATION FLASKS FLASK STOPPERS FLASK SUPPORT BOARDS amp RECEIVERS Refer to tables on page 29 THERMOMETERS ASTM2C 3C 7C 8C 37C 38C 39C 40C 41C 42C 102C 103C 104C 105C 106C 107C or BS 593 100mm immersion IP75C for condenser alternative to 11867 0 Digital thermometer ASTM38C IP78C and ASTM40C IP80C for BS 658 only Note Other items that may be required include Petroleum spirit 60 80 Receiver cooling apparatus b OPTIONAL 11869 0 D86 DISTILLATION KIT Groups 1 to 4 comprising 125ml NS 19 26 Distillation Flask NS 19 26 Thermometer centering device Flexible Stopper Caps for side arm x 5 100ml Receiver 33mm Flask Support Board 50mm Flask Support Board 50 ASTM7C Thermometer ASTM8C Thermometer Condenser Cleaning Tool Boiling Stones 11865 3 SETA CONDENSER LID with thermometer support and receiver stand 11866 0 SETA ANTI SPLASH PLATE for 100ml r
322. k and easy viscosity check Viscosity range 40 to 1400 Saybolt seconds and 0 to 400mm s 5 accuracy Plunger action sampling Calibrated scale A pocket sized quick on site viscosity test for in service lubricating oils and similar applications The Visgage contains two tube and ball sets graduated and calibrated in Saybolt seconds 100 F or Centistokes mm s 40 C depending on model One tube is factory filled with a reference oil while the other can be loaded with the sample by a simple plunger action By tilting the Visgage until the ball in the reference oil reaches a calibration mark the position of the ball in the sample tube can be read directly on the graduated scales giving the viscosity in Saybolt seconds With practice an accuracy within 596 of true viscosity can be achieved SUPPLIED WITH pocket carrying case with operating instructions and reference table of the approximate dilution of lubricating oils by diesel fuel contamination Viscosity Seta part No Description 40 to 800 Saybolt Seconds 100 F 95000 0 VISGAGE FOR LIGHT OILS 400 to 1 400 Saybolt Seconds 100 F 95010 0 VISGAGE FOR HEAVY OILS 0 to 400 Centistokes mm s 40 95020 0 VISGAGE FOR LIGHT OILS 20 to 400 Centistokes mm s 40 C 95030 0 VISGAGE FOR HEAVY OILS Size HxWxD 5x5x 25cm Weight 0 5kg SETA TRI GAUGE VISCOSITY COMPARATOR Ideal for In Service lubricant oil testing Rapid and easy Go No Go viscosity test Quick
323. k of 10 25000 3 e e e 21142 0 STRAIGHT RING pack of 10 25300 0 e 21143 0 TAPERED RING pack of 10 99100 2 9 e 21144 0 BALL 9 525mm diameter 3 5 0 05g pack of 30 99856 0 Calibration 21160 3 BALL CENTRING GUIDE pack of 3 Thermometers THERMOMETERS ASTM15C IP60C Refer to the table of ITEMS REQUIRED FOR EACH TEST ASTM16C IP61C e CALIBRATION vERIFICATION amp TRAINING kasa 99856 0 SETA MULTI TEST VERIFICATION MATERIAL IP 58 Bitumen STPTC T3d e for details see page 151 STPTC T9d e Drop point Hardening amp Softening DROP POINT APPARATUS POINT APPARATUS 11600 0 11610 0 11700 0 PETROLATUM DROP POINT APPARATUS IP 31 obs IP 371 BS 894 A 600ml glass liquid bath with cover retort stand clamp and thermometer cork a glass air bath with thermometer cork and air bath thermometer assemblies for IP tests BS894 assemblies are available as accessories Air bath thermometer assemblies comprise a thermometer cemented to a sleeve a case that screws onto the sleeve and a chromium plated brass cup that clips onto the sleeve SUPPLIED WITH air bath thermometer assembly PHARMACOPOEIA DROP POINT APPARATUS Euro Pharm 2003 Method Ill Test A Comprises a 1litre borosilicate glass bath complete with cover retort stand mounting clamp and thermometer cork a borosilicate glass test tube air bath with a grooved thermometer cork and an air bath thermometer assemb
324. k of 2 FILTER FILE notebook with 10 filing pages and 500 mini envelopes to hold filters LABORATORY OVEN for details see page 137 SETAPLUS EXTENDED 12 MONTH WARRANTY Note Other items which may be required include Hoses Solvents Balance 19724 0 FILTRATION KIT ASTM D6217 IP 415 Filtration test for Middle Distillates Comprises 0 8 micron Filter stainless steel Filter Holder with stainless steel screen Filter Forceps 25mm Solvent Filtering Dispenser 2 x Vacuum Filtering Flasks 1 litre cylinder Watch Glass and Tubing 19725 0 99100 2 99200 2 99205 0 99206 0 Filtration ale af Ui Tit VACUUM PUMP amp REGULATOR ANALYTICAL BALANCE for details see page 141 LABORATORY OVEN for sample pre conditioning for details see page 137 DESSICATOR 200ml and disc 19720 0 only SILICA GEL 19720 0 only 91600 3 Particulates SETA MFT MULTI FILTRATION TESTER ASTM D2068 IP 387 Procedures A B amp C Correlates with ASTM D6426 COLD SOAK IP PM EA 08 Portable test for filterability blocking tendency of Fuel Oils Testing of Bio components including FAME material and cold soak testing Easy to use fully automated operation Large LCD display Results in less than 15 minutes Automatic calculation of FBT and F QF Simple calibration verification of flow pressure and temperature Interface for PC or Printer Downloadable Filterability Graph
325. kPa 0 44psi maximum pressure Dry compressed air 670kPa 100psi maximum pressure Water 5 C and above Water Ethylene Glycol 50 50 below 5 C 125kPa 18psi maximum pressure 110 120V or 220 240V 50 60Hz switchable 34x 47 x 42cm Multi Method Flash Point 34700 0 mounted on a 34000 0 Base Unit with a 34010 0 Draught Screen fitted BIO FUEL TESTING SETALERT COMPATIBLE EID CALIBRATION amp VERIFICATION MATERIALS WE WW TECHNICAL DATASHEETS AVAILABLE 00100 0 13770 311 99878 3 99910 0 99928 0 PRINTER CCESSORIES Small Scale Closed Cup Module SETALERT REMOTE PAGING SYSTEM SYRINGE 4ml for tests above 100 C SPIRIT LEVEL RS232 CABLE for connecting instrument to PC CRYOSTAT 20 C For tests to 10 C COOLING BOOST MODULE DRAUGHT SCREEN recommended for gas tests SMALL SCALE CERTIFIED FLASH POINT MATERIAL for details see page 156 PORTABLE DIGITAL BAROMETER 750 to 1500 mbar absolute for details see page 145 SETATHERM for details see page 129 13740 004 13770 004 34200 005 34700 001 81002 001 CONSUMABLES Small Scale Closed Cup Module SAMPLE WELL 0 RING viton pack of 5 1 SAMPLE WELL 0 RING silicone 5 1 EOSAXPIALIGNIUE E E EE E EE a 2 EBASHIDETEGTOR Fauan na nan n s E T ns 2 PRINTER PAPER pack of 20 rolls ce ne ee 1
326. l fuel oils Consists of two filtration cells heating steam and cooling water circuits and a vacuum circuit with Buchner flask and gauge Each filtration cell comprises a steam heated water cooled brass cup with a sintered brass disc to support the microfibre filters Temperature test points are fitted into the steam input lines and a digital indicator and probe are available as an accessory SUPPLIED WITH Buchner flask with safety cover 2 filtration cells 100 filters and instruction manual SETAPLUS EXTENDED WARRANTY AVAILABLE E Test samples 10g Waste flask capacity 500ml Filters 2 per cell 47mm dia Whatman type GF A Steam 100 C Vacuum 40kPa absolute pressure Cooling Water ambient temperature Services Connections 10mm dia riffled nozzles Size HxWxD 40 x 47 x 18cm Weight 8kg SETA EXTRACTION APPARATUS ASTM D473 IP 53 API 2561 ISO 3735 BS 4382 obs FTM 791 3002 NF M07 010 Sediment content of crude and fuel oils Determines sediment content of crude oil and fuel oils by extraction with toluene The sample is placed in a refractory thimble and washed with condensed toluene vapours leaving only insoluble matter the residue is calculated as a percentage of the total mass Comprises a tinned copper condenser coil alumina refractory thimble of porous grade and an Erlenmeyer flask of one litre capacity ACCESSORIES Extraction Apparatus 21310 0 BASKET THIMBLE SUPPORT ribbo
327. l the duration of the test If the torque exceeds a preset level or the balls weld during a test power to the drive motor is automatically turned off The optional Seta 19940 0 Wear Loading Kit allows the user to quickly convert the equipment into a Four Ball Wear Tester for ASTM D2266 and D4172 tests SUPPLIED WITH 1200 test balls to DIN 5401 and instruction manual CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE ENAA TECHNICAL DATASHEETS AVAILABLE DOGO ACCESSORIES 4 Ball Lubricant Testers REQUIRED Elevated Temperatures ASTM D2266 D4172 19840 0 SETA HEATING PAD AND CONNECTING LEAD 19850 3 SETA TEMPERATURE CONTROLLER INDICATOR for 19840 0 Voltage 110 120V or 220 240V 50 60Hz switchable SETA THERMOCOUPLE for torque arm on standard Seta 19800 5 and also for Rolling and Sliding Contact Torque Arm 19810 0 One required for each torque arm used REQUIRED Viscosity Shear Stability CEC L 45 T 93 19820 0 SHEAR STABILITY HEAD comprises tapered roller bearing and jacket 19830 3 SETA TEMPERATURE CONTROL SYSTEM for use with 19820 0 comprises a circulating water bath with fittings for heating and cooling and a digital indicator Voltage 19860 0 110 120V 50 60Hz 220 240V 50 60Hz Note CEC Reference Fluids available see Calibration Verification amp Training Note Other items which may be required include Pitting detector Accelerometer and Time Lapse Recorder For
328. line screw clips connecting tubes and instruction manual 16500 0 Stand amp clamp supplied separately SPECIFICATIONS ACCESSORIES Demulsification Apparatus REQUIRED 10720 0 SETA BURNER for coal gas OR SETA BURNER for LPG OR SETA BURNER for natural gas Methane OR SETA HOT 1000W electric heater with variable heat control for details see page 137 SETA STEEL STAND 24520 0 CLAMP 2 to 90mm diameter capacity 24650 2 BOSSHEAD to fit 24520 0 THERMOMETERS IP3F or IP3C OPTIONAL 22750 2 DIGITAL STOPWATCH hand held 0 1s resolution for details see page 141 10740 0 10750 0 25000 3 24500 0 Foaming Air Release amp Emulsification Air Release AIR RELEASE RELEASE SETA AIR RELEASE VALUE APPARATUS ASTM D3427 IP 313 BS 2000 Part 313 DIN 51 381 ISO 9120 NF T60 149 15850 4 Ambient to 75 C temperature range e 200kPa maximum air pressure 23l min maximum flow rate Optional automated density monitoring 15880 6 15870 4 15850 4 and 15880 6 Balance supplied separately SETA DENSITY BALANCE Determines the time taken for hydraulic fluids and lubricating oils to release entrained air and gases The main unit comprises an air heater fine control pressure regulator pressure gauge and mounting clip for the test vessel An interlocked 3 pin socket provides power to an external air pump not supplied when the heater is on The di
329. ling 2 5 bmm AvCount Service Kit AvCount Particle Counter Battery 81 Sample Probe Sample Tube and Stopper AvCount Exit Tube Assembly Particle Sensor 45 50 Double Pump Electronics Module and Display Display and Membrane Panel Exchange Cell 45 50 Exchange Double Pump Printer Membrane Micron Filter Tube Assembly Hose Coupling 4 6mm Hose Coupling 2 5 4mm Hose Coupling 2 5 bmm AvCount Service Kit H2S Analyser 88 Calibrated Sensor Test Vessel pack of 5 Filters pack of 5 Diluent 500ml Tubing Kit Carbon Inlet Filter Syringe pack of 200 Exit gas Tubing 2 metres Liquid Trap pack of 5 Engineers Tubing Kit H2S Replacement Gas H2S Replacement Regulator Pipette Tips Consumable Kit Annual Service Kit PC Connectivity Kit FIJI FAME in Jet Instrument 89 Sample Inlet Assembly Sample Waste Assembly Cartridge Feed Assembly USB Cable single Fuses pack of 2 Power Supply Beakers 50ml pack of 10 Beakers 50 ml pack of 50 Beakers 50ml pack of 100 Fiji Cartridge pack of 10 Fiji Cartridge pack of 50 Fiji Cartridge pack of 100 Beakers 250ml pack of 10 spare Parts Index Product Number Part Numbers in bold are main description Part Number 00100 0 SETALERT REMOTE PAGING SYSTEM 00100 001 SETALERT TRANSMITTER 10000 0 THIN FILM APPARATUS 10120 2 TRANSFORMER UNIT 10160 0 GLASSWARE FOR ANILINE POINT METHODS 10200 004 STIRRER ROTOR pack of 5 10400 0 SMOKE POINT APPARATUS 1
330. livery For air and non corrosive gases Oil Free Sintered air intake filter Pressure relief valve SUPPLIED WITH instruction manual AIR PUMP Pressure or vacuum delivery Non pulsating rotary vane For air and non corrosive gases Oil Free Vacuum and pressure relief valve SUPPLIED WITH instruction manual VACUUM PUMP High vacuum Two stage Non pulsating rotary vane Gas ballast valve Oil mist filter SUPPLIED WITH tubing lubricating oil oil mist filter and instruction manual VACUUM PUMP High vacuum Two stage Direct Drive sliding vane Gas ballast valve Oil sealed SUPPLIED WITH instruction manual Mim ows vn NN LN NN 220 240V 50 60Hz LIN I NN w SPECIFICATIONS n m 220 240V 50 60Hz ra w g SPECIFICATIONS Minow Pow wee amesa Poe 220 240V 50 60Hz LIN T NN ww je _ Moun NC Po w Se SE ww KEEN 14030 2 14031 0 22422 6 80004 0 Heating General Laboratory Equipment 99200 2 99205 0 25000 3 16130 3 LABORATORY OVEN Temperature range ambient 5 to 220 C 53 litre capacity Fan for even temperature distribution 999 hour timer RS232 port Corrosion resistant stainless steel Calibrated A digitally controlled oven suitable for heat storage heat treatment and drying processes at temperatures up to 220 C for
331. ly The air bath thermometer assembly comprises a thermometer cemented to a sleeve a case that screws onto the sleeve and a chromium plated brass cup that clips onto the sleeve SUPPLIED WITH air bath thermometer assembly LUBRICATING GREASE DROP POINT APPARATUS ASTM D566 IP 132 DIN 51 801 ISO 2176 NF 160 102 FTM 791 1421 JIS K2220 Comprises a 600ml borosilicate glass bath complete with cover retort stand mounting clamp and thermometer cork a borosilicate glass test tube air bath with thermometer cork a thermometer guide cork 1 5mm dia support rod and a chromium plated brass sample cup CALIBRATION amp VERIFICATION MATERIALS CONSUMABLES Drop Point Apparatus 2 Years 2000 Tests 11600 0 only 10200 005 11600 001 11600 003 11600 004 11600 005 BEAKER spoutless 600ml pack of 5 CUP brass pack of 5 IP140C THERMOMETER SLEEVE amp CASE IP141C THERMOMETER SLEEVE amp CASE BOILING TUBE pack of 10 2 Years 2000 Tests 11610 0 only 11610 001 11610 002 11610 003 11610 004 2 Years 2000 Tests 11700 0 only 10200 005 11700 001 THERMOMETER SLEEVE amp CASE CUP brass pack of 5 BEAKER spoutless litre pack of 5 BOILING TUBE pack of 10 BEAKER spoutless 600ml pack of 5 CUP brass pack of 5 11700 002 TEST TUBE amp ROD pack of 10 24500 0 24600 0 amp 24640 0 11600 0 25000 2 Typical Drop Point setup 2 11600 003 ACCESSORIES Drop
332. m flow time of 200 seconds at 37 8 C CALIBRATION CERTIFICATE WORKS Note If a full set is not required individual tubes are available as follows Seta PartNo Nominal Constant Sample Volume ml Viscosity Range mm s 83602 001 0 1 0 3 6 to 60 83602 002 0 3 0 3 18 to 180 83602 003 1 0 4 60 to 600 83602 004 3 0 5 180 to 1800 83602 005 10 0 5 600 to 6000 83602 006 30 0 5 1800 to 18000 83630 0 BITUMEN ACCESSORY adaptor plate to accept bitumen viscometer tubes and thermometers 83710 0 HYPODERMIC SYRINGE for bitumen sample pack of 10 SETA KINEMATIC VISCOSITY BATH THERMOMETERS FOR BITUMEN TESTS With ice point scale and 0 02 C subdivisions allow easy reading to within 0 01 C accuracy better than 1 subdivision CALIBRATION CERTIFICATE WORKS D CALIBRATION CERTIFICATE UKAS OPTIONAL 83570 0 83700 5 99300 2 45002 0 Kinematic Capillary Viscosity SETAVIS MANUAL KINEMATIC VISCOMETERS ACCESSORIES Continued SETA BACK FLUSH KIT for cleaning blocked tubes in situ Comprises wash bottle and tubing SETA UNIVERSAL PRE HEATING AND FILTERING KIT for use with transparent and opaque samples Comprises hot plate support high temperature 75 micron reusable filter unit and 100 low temperature disposable sample containers with 100 associated 75 micron filters and covers MINI LOW TEMPERATURE BATH CIRCULATOR to provide chilled water if local s
333. maximise washing efficiency and is capable of cleaning heavy deposits such as D86 flask residual SUPPLIED WITH cleaning basket and tank lid 220 240V 50 60Hz 100 130V 60Hz I 25 x 17 x 16cm external 10 x 15 x 13 5cm bath Voltage Size HxWxD 99320 2 REMOTE PAGING ALARM l 00100 0 SETALERT REMOTE PAGING SYSTEM Visual and audible indication 6 channel rechargeable receiver Transmitter powered by the instrument or PC computer Each transmitter uniquely coded Nolicence required in UK Fits in pocket or can be belt worn SPECIFICATIONS TRANSMITTER Operating frequency 433MHz Range 300 metres maximum wi ms Power Supply Size HxWxD 3x5x7 5cm antenna 17cm RECEIVER 6 individual coloured LEDs and audio prompt Power Rechargeable Duration 5 days per charge Recharger Supply 100 to 240V 50 60Hz universal Powered from instrument PC A 6 channel laboratory pocket radio paging system where the operator is notified by the instrument when a test has been completed or assistance is required Setalert is compatible with the following Stanhope Seta instruments 34000 0 Multiflash 81000 2 Setavap 2 Size HxWxD 2x6 5 x 12cm antenna 3 4cm 91600 3 Seta Multi Filtra
334. ment Tomp Ronge GRRE HCFC free Refrigerant R600a Spark resistant interior Net Capacity 115 litres For safe cooling and chilled storage of volatile e ae products spark resistant refrigerators are Voltage 220 240V 50hz essential m HxWxD 85 x 50 x 56cm external The storage compartment can maintain Weight 20kg temperatures in the range of 0 to 10 C adjustable by a thermostat The refrigerator is equipped with two storage shelves and a lower drawer The door seal is replaceable To safeguard the integrity of samples the refrigerator is fitted with a lockable door that can be converted to left or right opening 93700 2 Timers and Balances General Laboratory Equipment ES 83750 3 Precision timing and verification of timing devices Six independent channels A quartz timer with six independent timing channels each with a range of zero to 999 99 seconds Each channel has start stop hold and memory retrieval functions A 9 way D type socket on the rear of the unit allows remote operation of all channels SUPPLIED WITH mains lead and instruction manual OPTIONAL CALIBRATION CERTIFICATE UKAS 22750 2 DIGITAL STOPWATCH Precision timing large LCD display Alarm Hand held digital stopwatch with LCD display in water resistant case SUPPLIED WITH battery and neckcord Weight 26 SETATIME SIX CHANNE
335. mersion contact and flexible probes Suitable for liquids gases and solids A compact PT100 electronic thermometer with clear display and fast response time The interchangeable temperature probes are connected to the handheld display via 1m cables The probes included are for the following applications liquid immersion solids surface and air amp gases A flexible probe for general use is also included SUPPLIED WITH four probes with leads carry case battery and user instructions CALIBRATION CERTIFICATE WORKS SPECIFICATIONS Accuracy 05 C 1 A Power Supply 9V 6F22 PP3 Alkaline Battery N inr 99927 0 Hydrometers Temperature amp Fluid Density ASTM HYDROMETERS HYDROMETERS All Seta Glass Hydrometers are manufactured from sodalime silicate glass with a linear coefficient of expansion of 9 2 x 10 6 They are shot poised and calibrated for use in liquids of LOW surface tension 15 to 34 dynes cm 7 CONFORMANCE CERTIFICATE To order a thermometer with a works conformance certificate quote the IP or ASTM part number i e IP39C 7 CALIBRATION CERTIFICATE UKAS order a thermometer with a UKAS calibration certificate add the suffix 2 to the IP or ASTM part number i e IP39CZ ASTM HYDROMETER AND THERMOHYDROMETER QUICK SELECTION GUIDE ASTM Ref to SETA PART No ASTM Ref to SETA PART No STA 2 GN ET RANGE TEMPERATURE TYPE 12355
336. mine particulate contamination and colour ratings SSAFCON assists the routine filtration performance tests such as ASTM D2276 IP 216 which are carried out at fuel terminals and throughout airport distribution systems The system provides a self contained and safer alternative to traditional hose end sampling eliminating trailing hoses and exposure to fuel in the airport service area SSAFCON mounting trays 16165 2 are permanently installed at the sampling points downstream of the filtration system typically ata designated static test site hydrant dispenser or onboard the fuelling vehicle SSAFCON Sampler 16160 2 connects to the mounting tray by self sealing quick release couplings and an earthing clip Docking undocking of the Sampler is rapid and safe An integral volume meter and pressure valve are used to control flow rate and monitor the volume of fuel passed through the filter After sampling the Sampler is quickly and safely disconnected from the Tray and the filter removed for gravimetric or colorimetric analysis SUPPLIED WITH fitting kit and full instructions SETAPLUS EXTENDED WARRANTY AVAILABLE TECHNICAL DATASHEETS AVAILABLE DID Size HxWxD Weight IL FILTRATION KIT IP 440 EN 12662 Filtration test for Middle Distillates Comprises 0 8 micron Filter Filter Membrane stainless steel Filter Holder with stainless steel screen Filter Forceps Vacuum Filtering Flask 2
337. mins 20mins 10 mins 10 mins 10mins 10 15 10 mins 10 90300 2 SETA BLOCK HEATER to dry heat tubes requires 90301 0 BLOCK for details see below 90301 0 BLOCK aluminium holds four 90040 0 90060 0 tubes for use with 90300 2 Block Heater 90202 2 RACK 5 place for 90011 0 tubes c a E zl 90203 2 RACK 6 place for 90040 0 90060 0 tubes CONSUMABLES Oil Test Centrifuge 90204 2 RACK 4 place for 90050 0 tubes Vaara 4 90041 2 STOPPERS pack of 50 99100 2 ANALYTICAL BALANCE for ASTM D893 for details see page 141 t Sample must be 52 C or above after test 90000 301 BOTTOM INSERTS pack 22 e I ub ME E UC DRE 8 90010 0 SETAFUGE HAZARD REDUCTION SYSTEM Vapour extraction and dilution SETAFUGE significantly reduces the hazards A vacuum switch continuously monitors the associated with vapours and gases released from vacuum inside the chamber and the unit Reduced chamber pressure to volatile samples and samples with added solvents interfaces with the centrifuge interlock to ensure prevent vapour seepage in centrifuges at elevated temperatures that safe procedures are always followed Safety interlock y Vapours are extracted from near the top of Note Requires an external compressed air the chamber diluted with air and discharged supply safely via a tube to a non hazardous area By maintaining the chamber at slightly below atmosph
338. mple ASTM IP TANK DIPPING THERMOMETERS ASTM Description Range IP Description Range 58C Tank 34 to 49 C 48C Tank Low 38 to 30C 58F Tank 30 to 120F 49C Tank Medium 15 to 40 C 59C Tank 18 to 82 C 50C Tank High 10 to 65C 59F Tank 0 to 180F 51C Tank Heated Fuel 35 to 120 C 60C Tank 77 to 260 C 52C Tank Bitumen 90 to 260 C 60F Tank 170 to 500 F 53C Tank Cargo 0 to 80 C 97C Tank 0 to 120 F 98C Tank 16 to 82C 98F Tank 60to 180 F 87530 0 LAB HOLDER 87530 0 A thermally insulated support that clips onto the side of a beaker or container allowing thermometers and probes to be suspended at the correct immersion depth without contacting the sides of the container The flexible probe mounting disk has 15mm 10mm 6mm 5mm and 3mm holes to accept most probes and thermometers The jaws of the spring loaded clip has thick pads to firmly grip onto glass walled containers 99940 0 SETA DIGI PETRO THERMOMETER SPECIFICATIONS Temperature Range 80 to 450 C 80 to 450 C temperature range Resolution 001 C 0 02 C accuracy between 20 to 120 C Ch 1 Precision Better than 0 02 between Unique glass temperature sensor n Ja Dual temperature display Ch 2 Precision 0 15 C and 0 2 of range Suitable for hand held or bench top use Temperature Stability 5ppm c Audible Alarm Start Increments of 1 0 C The high performance Digi Petro thermometer is an alternative to a mercury therm
339. mple cup Non sparking design Non sparking design complying with ASTM and IP recommendations Fitted with a retaining handle at the top of the case for attaching cord a 100ml cup at the bottom for collecting the sample and two clips to retain the thermometer Suitable for ASTM58C 58F 59C 59F 60C 60F and IP48C 49C 5OC 51C 52C and 53C thermometers Brass and acrylic construction graduated from 0 to 350mm and grooved on one side to accept a thin layer of water or gasoline finding paste Conforms with IP M14 Metric CALIBRATION CERTIFICATE WORKS SPECIFICATIONS WATER ULLAGE FINDING MATERIALS Supplied in 100g jar pack of 10 WATER ULLAGE FINDING MATERIALS 87520 0 with Seta Part Description Thermometer 14630 0 Water Finding Paste lusteuguliedi 14640 0 Gasoline Ullage Paste EP Pressure Samplers Tank Sampling amp Gauging SAMPLING CYLINDERS CYLINDERS ASTM D1265 IP 51 obs IP 104 obs IP 181 obs ISO 4257 BS 2000 Part 104 obs BS 5309 Parts 2 amp 3 NF M41 001 46bar 670psi maximum working pressure Single and double valve models 1 8in BSP connections Outage tube on double valve versions 1316 Stainless steel body and valve A range of heavy duty stainless steel single and double valve sampling cylinders suitable for drawing LPG samples from pressurised storage and transferring them to laboratory equipment The outage tube end is marked on double valve cylinders SINGLE VAL
340. mple cup is cooled by forced air to reduce the cycle time between tests Up to 64 results can be stored in memory tagged with operator and sample references and can be downloaded to a PC or printer via the RS232C port USB or LAN ports available as options The firmware is ENA D 9 TECHNICAL DATASHEETS AVAILABLE DEN LIMAY F upgradeable for future developments Mam sem SUPPLIED WITH Ignitor 2ml syringe mains lead and instruction manual iw Lal Seta Part No 82100 0 82150 0 82000 0 Air 10 to 130 C 50 to 266 F Water Assisted 20 to 130 C 4 to 266 F Air 10 to 130 C 50 to 266 F Water Assisted 20 to 130 C 4 to 266 F Temperature Range Ambient 5 to 300 C Ambient 9 to 572 F Sample Size 2 or 4ml according to method 2 or 4ml according to method 2 or 4ml according to method Ignitor Electrical Hot Wire optional Gas Flame Electrical Hot Wire optional Gas Flame Electrical Hot Wire optional Gas Flame Test Modes Rapid Equilibrium and Ramp Rapid Equilibrium and Ramp Rapid Equilibrium and Ramp Test Duration 1 minute below 100 C 2 minutes above 100 C 1 minute below 100 C 2 minutes above 100 C 1 minute below 100 C 2 minutes above 100 C Rapid Equilibrium Mode Test Duration Ramp Mode Cool Down Time Sample Cup Material Heating Cooling Method Computer Interface Power Voltage Size HxWxD
341. mum 63 x 85 x 38cm 52kg ITEMS REQUIRED FOR EACH TEST Seta PartNo D3603 D5534 D665 NACE PartA PartB Procedure A ProcedureB ProcedureC TM0172 2001 Distilled Synthetic Sea Heavier than Water Water Water Fluids 11210 2 e 11220 0 11240 0 e e e 11250 0 11260 0 e 11275 0 e e e 11280 0 e e e e 11290 0 m 11325 0 e 11330 0 e e 11335 0 e e Items marked lil are used when testing synthetic oils CONSUMABLES Rust Prevention Test Bath 2 Years 2000 Tests 11200 005 BEAKER 400ml pack of 10 11200 503 STIRRER pack of 2 11225 0 SYNTHETIC SEA WATER SOLUTION ASTM D665 procedure B 30ml pack of 10 SYNTHETIC SEA WATER SOLUTION ASTM D665 procedure B 300ml 11227 0 Note Other items which may be required include Naptha Distilled Water Corrosion amp Rust Corrosion amp Rust RUST PREVENTION TEST SPECIMENS amp HOLDERS 11220 0 VERTICAL TEST SPECIMEN amp ACRYLIC HOLDER r ASTM 0665 Procedures B amp A CONFORMANCE CERTIFICATE lt WORKS Comprises a vertical test specimen 11220 001 with an acrylic holder j and beaker cover for testing non synthetic oil samples Pack of 5 11220 0 11290 2 VERTICAL TEST SPECIMEN amp PTFE HOLDER ASTM D665 Procedures A B amp C NACE TM0172 2001 CONFORMANCE CERTIFICATE em WORKS A PTFE version of the 11220 0 for testing synthetic oil samples and gasoline tests to NACE TM0172
342. mushroom 13mm diameter spherical and 1 inch diameter cylindrical electrodes spacing gauge spare magnetic stirrer bars 400ml oil test vessel and instruction manual VOLTAGE CALIBRATION METER 100kV maximum voltage Automatic operation 99625 0 SPECIFICATIONS Voltage 110 120V 50 60Hz 220 240V 50 60Hz Power 750W Size HxWxD 47 x 50 x 32cm Weight 41kg ACCESSORIES Automatic Oil Testers OPTIONAL 99605 0 OILTEST VESSEL with motorized stirrer 800ml capacity for ASTM D1816 only 99620 201 OIL TEST VESSEL 13mm dia spherical electrodes 99620 202 OIL TEST VESSEL 36mm dia mushroom electrodes 99620 203 OIL TEST VESSEL 1 inch dia cylindrical electrodes 99606 0 TRANSPORTATION TROLLEY CALIBRATION VERIFICATION amp TRAINING VOLTAGE CALIBRATION METER CALIBRATION amp VERIFICATION MATERIALS 99625 0 An automatic meter to test and calibrate up to 100 on Automatic and Portable Oil Test Sets to an accuracy of 396 f s d over a temperature range 0 to 40 SPECIFICATIONS Sewo LPG Density SPECIFIC GRAVITY 22100 0 PRESSURE HYDROMETER APPARATUS ACCESSORIES Pressure Hydrometer ASTM D1657 obs IP 59 Method C obs IP Refer to the table of ITEMS REQUIRED FOR EACH TEST and select from the following x 235 IS0 3993 NF M41 008 obs JIS K2249 options 22580 2 SETA PRESSURE GAUGE 0 to 2000 kPa 0 to 290 psi 1400
343. n a cotton wool plug impregnated with Cobalt Bromide is exposed to the vapour under pressure A colour change indicates Wet or Dry in accordance with GPA 2140 SUPPLIED WITH instruction manual ASTM D1142 Bureau Of Mines type Accuracy 0 1 C To determine the water vapour content by measuring the dew point The sample enters a stainless steel chamber and passes across a mirror cooled by a refrigerant The temperature at which water vapour starts to condense on the mirror is indicated by a thermometer viewed through a pressure resisting window SUPPLIED WITH instruction manual SPECIFICATIONS Vii PI Size HxWxD Weight 20x 20 x 10cm 5kg SETA PRE COOLING APPARATUS ASTM D1837 D2158 IP 317 NF M41 012 Comprises a soft copper cooling coil in a wide mouth dewar flask supported in an insulated metal case An outlet valve controls the flow of liquid Size HxWxD 50 20 20 y Weight 3kg 0 WATER VAPOUR 20x 4x dom Weight 1 kg 22150 2 DIGITAL STOPWATCH for details see page 141 Freeze Valve 2 00 ests 97500 002 FILTER EPEMEINT aaa 1 97500 003 BODY GASKET pack 5 1 97500 005 RETAINING RING packofl0 1 SP ECIFICA IIU N Size HxWxD
344. n 50ml bottles 99878 3 13667 0 PORTABLE GAS TANK e Re fillable On Off switch e Controllable flow Flow Rate 0 20g hr adjustable Gas Butane standard gas lighter refill cartridge A portable Butane gas supply suitable for Size HxDia 23x 25cm Setaflash instruments The tank incorporates an On Off switch and an adjustable flow Weight filled 150g sufficient for approx 90 mins control valve The tank is easy to refill from an Butane cartridge The 13667 0 is integral to Setaflash Series 3 ACCESSORIES Portable Gas Tank and will connect directly to the gas inlet on Series 8 SUPPLIED WITH 30cm length of gas tubing 13666 0 BUTANE REFILL CONTAINER pack of 10 stand ignitor and instruction manual Note Also suitable for use with all older models of Setaflash and replaces the 13745 0 gas valve 13887 0 connected to a Setaflash Series 7 13747 0 SOLID SAMPLE DISPENSER Consistent sample size Clean mess free operation Accurately loads solids pastes powders and other samples which cannot be discharged from a hypodermic syringe into closed cup testers 13747 0 filling a Sample Cup 26000 0 LIQUID RECOVERY SYSTEM Safe removal of hot residue Collection of spillage Although intended for the safe removal and collection of hot residue from flash and fire point testers this item will fulfil many similar uses in the laboratory Comprises a small suct
345. n 90 D86 IP 123 327 2 C 100ml Distillation 95 D86 IP 123 346 2 C 100ml Distillation FBP D86 IP 123 358 1 100ml Distillation Residue D86 IP 123 1 3 vol 100ml Distillation Loss D86 IP 123 0 6 vol 100ml Flash Point D93 IP 34 66 6 C 75ml Cloud Point D2500 IP 219 6 3 C Up to 38ml CFPP IP 309 19 7 C 45ml Pour Point D97 IP 15 28 3 C Up to 38ml Kin Vis 40 C D445 IP 71 2 567 2 5 Up tp 40ml Lubricity HFRR D6079 IP 450 207 1 2ml Water Karl Fischer D1744 IP 438 60 138mg kg 5ml Reference Materials amp Standards STVM E SINGLE TEST VERIFICATION MATERIALS Single test verification Fully traceable in conformance with ASTM CEN ISO IP guidelines Small pack size 50ml containers Single Test Verification Materials STVM enable individual tests and instruments to be validated The volume of verification material in each container has been chosen to ensure that there is little wastage after completion of verification tests and reducing the risk of using a verification material that has been accidentally contaminated by another user STVMs allow highly accurate monitoring of instrument performance and operator technique STVMs are blended by a major multi national refining company in conformance with ISO 9001 and ISO IEC EN 17025 ISO Guide 25 and EN 45001 and tested internationally by a statistically significant number of laboratories to determine certified values Seta STVMs
346. n Aviation Turbine Fuels SA5020 0 FIJI VERIFICATION FLUID 30 mg kg Test duration unn SA5021 0 FIJI VERIFICATION FLUID 100 mg kg SA5025 0 CALIBRATION MATERIAL SET Sample size 50ml Operating temperature range 5 to 40 C maximum 80 RH Computer interface 2 x USB Computer running FIJI software is required 9 i finc CONSUMABLES FIJI Fame in Jet Instrument Power 50W maximum Molten 00 250V 50 60H SA5004 050 BEAKERS 50ml pack of 50 ane eee Sue SA5005 010 FIJI CARTRIDGE pack of 10 Size HxWxD 36 x 37 x 45cm 5 5005 050 FIJI CARTRIDGE pack of 50 Weight 16kg SA5005 100 FIJI CARTRIDGE pack of 100 44 0 1932 564391 F 44 0 1932 568363 E sales stanhope seta co uk w www stanhope seta co uk 89 Particulates Residues amp Composition Composition ESTERCHECK A portable instrument for the measurement of Diesel Bio Diesel FAME mixture SA3000 2 EN 14078 Correlation Contamination warning Instant measurement Accurate to less than 1 Bio Diesel Hand held robust enclosure IP 64 rated Rechargeable battery operated Simple display Stainless steel easy clean sensor Automatic calibration Patent pending With increasing instances of material compatibility problems with FAME products such as fuel pumps the measurement of bio ester in diesel is now a key test parameter for many users Recent advances in RF sensor technology provide a portable and low cost solution for SA3
347. n Dioxide For ASTM D1072 Purified Air Flowmeter to measure gas flow rate to burner stanhope seta co uk w www stanhope seta co uk Tribology amp Bearing Lubrication Tribology h BALL LUBRICANT TESTERS BALL LUBRICANT TESTERS SETA SHELL 4 BALL EP LUBRICANT TESTER WITH AUTOLOAD SYSTEM 19900 2 ASTM D2596 D2783 IP 239 IP 300 Procedure A amp B obs EN ISO 20623 ISO CD 11008 CEC L 45 T 93 ASTM 02266 amp 04172 when used with Wear Loading Kit 19940 0 Applied loads range 40 to 800kgF Drive speed from 720 to 1900rpm Timer range 0 1s to 9999hr Torque measurement and limiting Full Digital Control Digital displays of Applied Load torque time Safety splash guard Determines the friction properties of extreme pressure oils and greases Used in tribology research laboratories and in the routine quality control of finished lubrication products A ball mounted in a chuck is rotated against three stationary balls ina pot containing the sample lubricant The digital speed controller has four programmable presets three are factory pre programmed with the most commonly used speeds A load adjustable in the range of 40 to 800kgF is applied to the balls via a balance beam and electric jack The applied load is displayed on a digital readout The torque transferred between the rotating and stationary balls is measured and displayed The digital timer with a range of 0 1 second to 9999 hours can be used to contro
348. n Glassware 94 Boiling Flask 500ml c w heat tube Reflux Condenser Thistle Tube Graduated at 50ml Gooch Crucible 25ml Copper Sampling Can 1 litre 121 Copper Sampling Can 500ml 121 Tinned Steel Sampling Can 1 litre 121 Tinned Steel Sampling Can 500m 121 Copper Sampling Can 1 5 litre 123 Cork with Brass Screw amp Washer Assembly pack of 5 Sampling Cage 122 Cork with Brass Screw amp Washer Assembly pack of 5 Thermostir 138 Fuse pack of 5 Heater Stirrer Motor Power PCB Display PCB Temperature Probe RoBOT Bath 64 Temperature Control Board Heatsink Assembly Temperature Probe Assembly Heater Gasket Nylon Bearing pack of 2 Thermometer Collar pack of 2 Heater Temperature Indicator AutoRoBOT Pressure Monitoring System 65 Pressure Control PCB Rotating Inductive Link Serial Chainer PCB Link Lead Assembly Lead Chasis to Head Link Lock Assembly Seta RoBot Software Pressure Indicator Assembly Computer Interface Lead RoBOT Oxidation Vessel 64 0 Ring Seal pack of 10 Right Angled Valve Glass Liner amp PTFE Cover 64 ASTM Cover pack of 10 Spring pack of 5 Accessory Kit for ASTM D4742 64 Glass Container amp PTFE Cover pack of 2 Colour Comparator 114 Sample Container pack of 5 Halogen Lamp 20W White Insert Replacements pack of 3 Multicolour Automatic Colorimeter 112 Lamp 5V 10W lens ended Optical Glass Cell 33mm ASTM D1500 Optical Glass Cell 50mm ASTM D156
349. n the sample cup SUPPLIED WITH Ignitor 2ml syringe mains lead and instruction manual ACCESSORIES Setaflash Series 8 13747 0 SETA SOLID SAMPLE DISPENSER for details see page 15 13770 311 SYRINGE 4ml for tests above 100 C o e 26000 0 LIQUID RECOVERY SYSTEM with pump and trap to remove hot sample from cup for details see page 15 e 71001 0 SETA VENT for details see page 19 e 99300 2 LOW TEMPERATURE CIRCULATOR for low temperature tests in high ambient temperatures see page 139 e o 45001 0 SETAPLUS EXTENDED 12 MONTH WARRANTY e e 99878 3 SMALL SCALE CERTIFIED FLASH POINT MATERIAL for details see page 15 99928 0 SETATHERM digital thermometer 20 to 150 C for details see page 129 e e e Note For gas options please contact Seta Small Scale Flash Point Flash Point Smoke Point amp Sustained Burning SETAFLASH SMALL SCALE FLASH POINT 62000 0 SETAFLASH SERIES 8 CLOSED CUP TESTER ASTM D3278 03828 07236 E502 IP 523 IP 524 IP 534 ISO 3679 ISO 3680 BS 3900 Part 13 BS 6664 Parts 3 amp 4 UN Class 3 Non viscous Flammable Liquids CHIPS Regulations EPA 1020A amp B Ambient 5 to 300 C ambient 9 to 572 F temperature range Small sample size 2 or 4ml Flash No Flash amp Ramp modes Electric ignitor with gas option Automatic dipping and flash detection 64 Test Memory amp RS232 Interface C or F Temperature
350. n type 21320 0 WATER CUP glass pack of 5 25000 3 1000W variable heat control for details see page 137 21300 001 THIMBLE with certificate of conformity 99100 2 ANALYTICAL BALANCE for details see page 141 Residues 16120 2 ACCESSORIES Setaclean Total Sediment Tester 14030 2 AIR PUMP for details see page 136 16130 3 SETA STEAM GENERATOR for details see page 137 16150 2 THERMOMETER stirring type as required by test method 94 to 106 C THERMOMETER ASTM22C IP42C Note Other items which may be required include Dessicator Beakers Syringe Weighing bottles Forceps Hotplate Solvents Mixer DIGITAL THERMOMETER AND PROBE to monitor steam input temperature ANALYTICAL BALANCE for details see page 141 LABORATORY OVEN for details see page 137 ULTRA STIRRER amp STAND Voltage 16125 0 99100 2 99200 2 99224 0 110 120V 50 60Hz 220 240V 50 60Hz 500W 24 x 65 x 80cm Power Size HxWxD Weight 1 6kg Speed 3 400 24 000 rpm 45000 0 SETAPLUS EXTENDED 12 MONTH WARRANTY SETA FUEL OIL AGEING BATH with 6 air wells for 3 duplicate tests microprocessor controlled heater stirrer is at 120 C 0 5 C Features low liquid and over temperature protection 110 120V 50 60Hz 220 240V 50 60Hz 1500W 16155 4 Voltage Power Size HxWxD 27 x 35 x 35cm Weight 10 5kg CONICAL FLASK pack of 10 AIR CONDENSER glass pack of 10 16156 0 16157
351. ncluding 100 FAME B100 Bio Blends and fuels containing other oxygenates Look for the Seta Bio logo in this catalogue Information at a glance For ease of use the following icons are used throughout this catalogue Bio Fuel testing Software included Test certificates available for this product Calibration and verification materials available Setalert remote monitoring compatible SetaPlus extended warranty available Technical datasheets available Contents Products 2 22 28 32 50 54 58 64 74 80 98 102 106 108 110 112 115 116 120 124 136 144 150 Flash point smoke point and sustained burning Vapour pressure Distillation Viscosity Cold flow and freezing point Hardening and softening Penetration Oxidation Corrosion and rust Particulates residues and composition Tribology and bearing lubrication Foaming air release and emulsification Separation and evaporation Centrifuge equipment Cetane Colour Conductivity and insulation LPG Tank sampling and gauging Temperature and fluid density General laboratory equipment Calibration and verification Reference materials and standards Indexes IV Method number index 158 164 170 173 Spare parts index Product number index General index Terms and conditions Fuel Specifications Table Stanhope Seta also manufacture instruments to measure products other than fuels including oils greases lubricants an
352. new methods are uploaded or old ones withdrawn There are three subscription types available 1 Global access Provides online access to all your company s employees worldwide for a 12 month period 2 Multi user subscription Provides access to you and a number of your colleagues for a 12 month period 3 Individual 12 month subscription For more information please contact the EI Publishing Team e pubs energyinst org uk or visit www energypublishing org Distillation Reterence Methods 11860 3 SETASTILL ASTM D86 D216 obs D447 obs D850 D1078 E133 IP 123 IP 191 IP 195 EN 3405 BS 2000 Parts 123 191 amp 195 BS 658 BS 7392 ISO 198 791 1001 NF M07 002 obs JIS K2254 Ambient to 400 C distillation range Adjustable height heater flask platform Toughened glass window Cooling fan The distillation unit mounted to the left comprises a flask support mechanism heater elements and the heater controller The flask is supported by a drop in ceramic glass support board mounted to a platform that is adjustable for height The quartz enclosed heating elements are attached to the platform and are powered by a solid state energy regulator and calibrated control A cooling fan is installed in the rear of the distillation unit to reduce cooling time between distillations A toughened glass observation window is fitted in the front of the distillation unit and a spillage collection tray w
353. nifold complete with control valve regulator and air pressure gauge SPECIFICATIONS O 20980 0 20990 0 SETA PRESSURE BLEEDING TEST CELL TYPE ASTM D1742 FTM 791 322 SPECIFICATIONS Comprises a tightly fitting cap and cover which contains a 75 No 200 sieve strainer a funnel for collecting separated oil and a 25ml beaker for retaining the oil 20990 0 20900 0 SETA GREASE SEPARATION APPARATUS IP 121 BS 2000 Part 121 DIN 51 817 SPECIFICATIONS DEF 222A CS 3107 SPECIFICATIONS Comprises a stainless steel separation cup with integral metal gauze cone 100g stainless steel weight and an oil cup 20900 0 20950 0 SETA GREASE SEPARATION APPARATUS DEF STAN 05 50 01 Method 9 SPECIFICATIONS Comprises a 24 mesh cm stainless steel gauze cone a neoprene lined beaker cover and a lipless beaker ACCESSORIES Grease Separation Apparatus All types OPTIONAL 99100 2 ANALYTICAL BALANCE for details see page 141 20950 0 Evaporation separation amp Evaporation OIL CONTENT OF WAXES CONTENT OF WAXES 20800 0 SETA OIL CONTENT OF WAX APPARATUS ASTM D721 D3235 IP 158 ISO 2908 NF T60 120 FTM 791 5431 Temperature controlled hot air Evaporation Unit Four 15ml bottle capacity Rack and pinion operated air tubes Three filter stick capacity Cooling Bath Kerosine Solid CO cooling medium The content of oil and solvents in waxes affect the melting point hardness an
354. nt Comparative Viscosity A Tri Gauge comparative viscometer allows the viscosity of the sample to be compared to two standards SUPPLIED WITH beaker syringes pipettes cuvette tongs and reagents Also supplied with instructions and a sturdy carry case Size HxWxD 17 x 47 x 36m Weight 8 1kg BIODIESEL TEST KIT Check for Density Water Viscosity and TAN Quick simple and on the spot quality assurance Gain confidence in biodiesel suitability for use Ensure correct storage occurs Maintain optimise and trouble shoot each stage of manufacture Check oil Ester base stocks for quality and acceptability The Seta Biodiesel Test Kit brings essential quality checks for Density Water Viscosity and TAN to where they are most needed Whether you are an end user or a manufacturer results are provided in minutes allowing the correct decisions to be taken at the right time As an end user the quality and batch to batch consistency of the biodiesel can be confirmed Stored fuel can quickly and easily be checked for degradation contamination and suitability for use As a manufacturer consistent production quality can be achieved Process optimisation and trouble shooting can be quickly and effectively monitored and carried out on site in minutes Ester base stocks can also be checked for suitability at point of delivery SUPPLIED WITH instruction manual and carry case LEAD IN GASOLINE TEST KIT Fully portable and less
355. nts due in respect of the sale have been paid If the customer sells the goods the proceeds of sale shall be held in trust for Stanhope Seta to the extent that it has not received payment for them in full 12 Shortages and error Any claim for shortage or error in consignment must be made promptly after receipt of the goods We reserve the right to reject any claim made after seven days 13 Health and safety regulations It is responsibility of the customer to ensure that all persons involved with equipment supplied by Stanhope Seta are fully briefed with the relevant instructions for use and with local regulations 14 Recycling Provisions for the end of life disposal of goods supplied or replaced as provided for in any regulations including those of the WEEE directive shall be under the Customer s control and cost unless mutually agreed otherwise in writing STANHOPE SETA London Street Chertsey Surrey KT16 8AP England T 44 0 1932 564391 44 0 1932 568363 sales stanhope seta co uk F E W www stanhope seta co uk
356. o 1 200 1 2 400 11641 09 N350 S600 500 to 2 500 2 5 450 11641 10 N1 000 2 000 1 600 to 8 000 8 0 500 11641 11 D5 000 N4 000 4 000 to 20 000 20 0 600 11641 12 N15 000 S30 000 ZEITFUCHS CROSS ARM VISCOMETERS Viscosity Range mm2 s Nominal Constant Size Code Seta Part No 0 6 to 3 0 0 003 1 11663 01 2 0 to 10 0 01 2 11663 02 6 0 to 30 0 03 3 11663 03 20 to 100 0 1 4 11663 04 60 to 300 0 3 5 11663 05 200 to 1 000 1 0 6 11663 06 2600 to 3 000 3 0 7 11663 07 12 000 to 10 000 10 0 8 11663 08 6 000 to 30 000 30 0 9 11663 09 20 000 to 10000 100 000 10 11663 10 UBBELOHDE VISCOMETERS Viscosity Range mm s Maul Size Code Seta Part No 7 0 3 to 1 0 001 0 11643 01 N 04 NO 8 0 6 to3 0 003 0 11643 02 N1 0 N2 1t05 0 005 0B 11643 03 N2 S3 21010 0 01 1 11643 04 3 6 6 to 30 0 03 1 11643 05 010 20 10 to 50 0 05 1B 11643 06 S20 N35 20 to 100 0 1 2 11643 07 N35 S60 60 to 300 0 3 2 11643 08 N100 S200 100 to 500 0 5 2B 11643 09 S200 N350 1200 to 1 000 1 0 3 11643 10 N350 S600 600 to 3 000 3 0 3C 11643 11 N1000 S2 000 1 000 to 5 000 5 0 3B 11643 12 S2000 D7 500 2 000 to 10 000 10 0 4 11643 13 D7500 S8 000 6 000 to 30 000 30 0 4C 11643 14 N15 000 S30 000 10 000 to 50 000 50 0 4B 11643 15 N15 000 S30 000 20 000 to 100 000 100 0 5 11643 16 N A N A 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk Viscosity Kinematic Capillary GLASS CAPILLARY KINEMATIC VI
357. o UU 133 LAT MTM 132 E BS 5309 Parts 2 amp 3 119 123 5339 112 BS 5859 MM 112 114 115 E E 85608 52 gt E 2 5 8 10 13 BS 7391 Obs ccc 93 BS 7 BS EN 2 8 12 13 CE EN 14470 1 Type 90 157 CEC L45493 98 99 GE 115 CFR 49 173120 ss 16 CHIPS Regulations 281013 Classification of dangerous goods for 2 8 12 13 carriage Viscous and non viscous liquids DEF 222A CS 3107 106 DEF STAN 05 50 01 Method 1 sus 33 DEF STAN 05 50 01 Method 9 i 106 Lg 1r M 80 81 133 DIN 995 60 DIN 51366 s 36 37 Lor M M3 LEO NNI M3 2 6 Lino RP 104 97 112 113 o 143 DIN es 85 Lolo E 38 DIN 31302 36 37 S AET 94 38 Ln rc E 58 60 DIN 51587 uuu 12 73 143 DLE 103 143 DIN 51595 4 aaa a 183 LE EMEN 50 51 121 Rr 30 DINSLI uuasusascssyasaspipwsuscussqaani 132 133 143 2 4 DUN W 87 I rr 108 90 DIN S1 B04 U NE 60 61 DINSA M 100 DINTO onn asi 68 70 74 143 m 106 DIN 52 004 r M3 LOAD 60 DIN 53224 47 84 EN 12 obs CE 22 24 ERNEA ERR 94 LED Mam 32 ENJIS v 41 Ill asi ete Simca 58 60 34 I Ul
358. ocedure A IP 69 Procedures A C amp D IP 402 obs IP 410 BS 2000 Parts 69 402 obs 410 ISO 3007 ISO 4256 EN 12 obs FTM 791 1201 NF 12 obs NF M07 007 NF M41 010 LPG JIS K2258 Accepts up to 6 pressure cylinder assemblies Temperature range ambient 5 C to 90 C 194 F Uniformity better than 0 1 C 37 8 C 0 2 F 100 F Digital temperature control Low fluid level and over temperature protection A floor standing water bath specifically designed for the determination of vapour pressure with Seta Reid or Seta Vapour pressure cylinders The stainless steel 80 litre water bath has a temperature range of ambient 5 C to 90 C and can achieve a test temperature of 37 8 C 100 F with a uniformity of 0 1 C 0 2 F A programmable digitally controlled thermostir unit combines the functions of heater temperature controller timer and stirrer The thermostir unit is equipped with an RS 232 port a switched output for an external relay a socket for an external PT100 temperature probe and alarms and cut outs for low fluid level and over temperature The 22210 3 will accept up to four 22410 0 and up to six 22400 0 Seta Vapour Pressure Cylinder Ullage Chamber assemblies SUPPLIED WITH 4 pressure cylinder mounting brackets mains lead and instruction manual Cylinders amp gauges supplied separately 22400 0 22410 0 RVP CYLINDERS ASTM 0323 D4953 Procedure IP 69 IP 402 obs BS 200
359. oint amp Sustained Burning MODULAR FLASH POINT TESTER 34700 0 SMALL SCALE SETAFLASH CLOSED CUP MODULE ASTM D3278 D3828 D7236 E502 IP 303 obs Parts 1 amp 2 IP 523 IP 524 IP 534 ISO 3679 ISO 3680 BS 6664 Parts 3 amp 4 BS 3900 Part A13 BS EN 456 EPA 1020 A amp B UN Class 3 Non viscous Flammable Liquids CHIPS Regulations Classification of Dangerous Goods for Carriage Viscous and Non viscous Liquids Rapid Equilibrium Tests Non Equilibrium tests Flash No Flash tests Flexible automated search ramp mode Ambient to 300 C 10 C to 300 C with optional cryostat Gas or electric ignition The Small Scale Setaflash Closed Cup Module comprises a Test Area DIPS pod Dipping Ignition Pilot Stirrer flash detector and all necessary cables to interconnect with the 34000 0 Universal Base Unit The Test Area consists of an electrically heated solid block bath sample cup with an integral temperature probe The bath has a network of internal passages and can be connected to a 34008 0 Cooling Boost Module allowing circulation of cooling fluid via a cryostat for sub ambient tests The hinged lid is equipped with a shutter and ports for the flash detector and injecting sample The DIPS pod contains the shutter actuator and ignitor dipping mechanism with a coaxial gas jet electric hot wire ignitor The temperature probe is a class A PRT and flash detection is by a precision thermocouple Safety features in
360. older vacuum filtering flask and vacuum I m pump Saree ee P E I 16920 0 STEEL CATALYST WIRE cut in metre lengths pack of 6 ITEMS REQUIRED FOR EACH TEST T for details see page 73 Fuels Fuels Oils Oils Oils AND Seta Part No ASTM D2274 ASTM Draft ASTM 0943 ASTM 04310 DIN 51 587 16930 0 COPPER CATALYST WIRE cut in 3 metre lengths pack of 6 for details see page 73 11470 0 16910 0 16921 0 PREFORMED COPPER STEEL CATALYST COIL pack of 6 for details see 16914 0 e page 73 Note alternative to 16920 0 16930 0 and 16940 2 16915 0 16950 0 ACCESSORY PACK for ASTM D943 comprises thermometer bracket two 116916 0 support rings and six each sampling tube holders sampling tube spacers 116920 0 m stainless steel sampling tubes with Luer connector stoppers oil level i indicator strips and 10ml syringes Excluding thermometer 16980 0 16921 0 169800 THERMOMETER SPECIAL for ASTM D943 80 C to 100 C graduated in 16930 0 6 0 1 C Immersion depth 76mm 116950 0 25000 3 SETA HOT 1000w electric heater with variable heat control 16980 0 for details see page 137 94635 0 BATH OIL 20 litres for filling bath for temperatures between 80 and 120C FOR 16900 5 16960 0 ONLY 99100 2 e e e e 99100 2 ANALYTICAL BALANCE for details see page 141 99200 2 e 99200 2 LABORATORY OVEN for details see p
361. ometer and is specifically designed to measure temperature in conformoity with ASTM IP and other standards used in the hydrocarbon industry and where such thermometers are the temperature reference Power Supply xo ra ro adaptor supplie Size HxWxD 20 x 6 8 x 3 5cm Audible Alarm Interval Increments of 0 1 C The instrument measures temperature over the range of 80 to 450 C with a precision of better than 0 02 C between 20 to 120 C It has a dual temperature display with facility to connect up to 2 sensor probes simultaneously Sensor Dimensions ae pu 22 overall lengt The instrument has a unique glass temperature sensor made of thermally stable glass and designed to simulate the response time and immersion characteristics of the equivalent ASTM or Sensor Cable 1m IP thermometer and has the same dimensions as a typical mercury thermometer Weight 210gm There are dual display channels allowing 2 simultaneous temperature measurements using an optional second sensor An integral programme allows the user to select start and interval temperature points and to set an audible alarm to activate as each temperature is reached For example at the required dip point during a flash point test Digital hermometers SETADIGIT CALIBRATED DIGITAL PRECISION THERMOMETERS 99928 0 30 to 50 C and 90 to 110
362. ompartment thermometer supplied with the unit OPTIONAL 94110 0 TROLLEY for 94100 2 only 11500 0 COPPER CORROSION TEST VESSEL for ASTM D5853 stainless steel O ring sealed screw top closure Max pressure 700kPa 100 psi CALIBRATION VERIFICATION amp TRAINING 99851 0 MULTI TEST VERIFICATION MATERIAL ASTM 02500 IP 219 ASTM D6371 IP 309 Gas Oil EN 116 for details see page 150 99852 0 MULTI TEST VERIFICATION MATERIAL ASTM D97 IP 15 Fuel Oil for details see page 151 99853 0 MULTI TEST VERIFICATION MATERIAL ASTM 097 IP 15 Lubricating Oil for details see page 151 99908 0 BIO FUEL MULTI TEST VERIFICATION MATERIAL for details see page 151 CLOUD amp POUR POINT BATH 11010 2 SETA CLOUD AND POUR POINT BATH ASTM 097 ASTM 02500 ASTM 05853 IP 15 IP 219 IP 441 BS 2000 Parts 15 amp 219 ISO 3015 ISO 3016 EN 23015 DIN 51 597 obs NF T60 105 791 201 JIS K2269 Four test positions Temperature range 9 C to 69 C A test bath with stainless steel cover and a drain tap Accommodates four test jackets and a bath thermometer SUPPLIED WITH four graduated jars corks insulating gaskets and discs BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS S Note Requires Freezing Mixture as specified in the test method ACCESSORIES amp Bath REQUIRED THERMOMETERS High Cloud and Pour ASTM5C IP1C or ASTM5F IP1F Low Cloud and Pour ASTM6C IP2C o
363. omprises a universal base unit that houses the display control and data acquisition functions and a series of interchangeable modules that allow the implementation of the required standard test methods Multiflash is ruggedly designed to provide simple and reliable operation and is specifically engineered to ensure a very low cost of maintenance PENSKY MARTENS A B amp C Closed Cup ASTM D93 E502 IP 34 IP 404 obs BS 2000 Parts 34 amp 404 obs ISO 15267 EN ISO 2719 JIS K2265 NF M07 019 DIN 51 758 791 1102 EPA 1010A GB T 261 ABEL Closed Cup and Equilibrium IP 170 IP 304 obs Part 2 IP 492 BS 2000 Part 170 BS 3900 Parts A8 and A9 BS 6664 Parts 1 and 2 EN ISO 13736 ISO 1523 BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS S 9 SETALERT COMPATIBLE CLEVELAND Open Cup sa ASTM D92 IP 36 EN IS0 2592 BS 2000 Parts 36 amp 403 obs DIN 51 376 ua TECHNICAL DATASHEETS AVAILABLE NF T60 119 JIS K2265 AASHTO T48 TAG Closed Cup ASTM D56 D3934 D3941 E502 IP 304 obs Parts 1 amp 2 IP 491 IP 492 ISO 1516 ISO 1523 FTM 791 1101 JIS K2265 SMALL SCALE Rapid Equilibrium Setaflash Closed Cup ASTM D3278 D3828 D7236 E502 IP 303 obs IP 523 IP 524 IP 534 ISO 3679 ISO 3680 BS EN 456 BS 6664 Parts 3 amp 4 BS 3900 Part A13 UN Class 3 Non viscous Flammable Liquids CHIPS Regulations Classification of Dangerous Goods for Carriage Visco
364. on is via a large button and display panel Alternatively using the supplied software it is possible to create test programmes with up to 25 steps on a personal computer and upload them to the viscometer when required SUPPLIED WITH four LV type spindles temperature probe spindle guard basic software mains lead and instruction manual SIMAIR TEST CELL ASSEMBLY ASTM D2983 IP 267 Method A Simulates the cooling rate of an air bath Liquid bath is held at the desired test temperature Each cell is independent and can be added at any time for a complete analysis no need for grouping samples unless desired Improved precision rapid turn around time and ease of analysis The SimAir test cell when used in conjuction with a suitable liquid bath accurately simulates the characteristics of an air bath conforming to the cooling rates in Annex 2 of ASTM D2983 and IP 267 Method A The SimAir test cell containing the sample is immersed in a liquid bath that has stabilised at the temperature required for final analysis Heat transfer through the SimAir test cell to the sample accurately replicates the cooling influence of an air bath with a cooling rate greater than 60 C hr see graph The stability of using a liquid bath at a fixed temperature and not having to rely on a controller to follow an accurate cooling curve leads to more consistant and accurate results SUPPLIED WITH stator rotor rotor support and quick
365. on page 25 OPTIONAL 22460 0 SETA MANOMETER ADAPTOR adapts customer s manometer to Seta 22400 0 Pressure Cylinder using plastic rubber tubing pack of 2 CHARGING SYSTEMS Select from TANK SAMPLING EQUIPMENT FOR RVP on page 123 WetMethod Vapour Pressure ooo gt WB SETA REID VAPOUR PRESSURE GAUGES 2 ASTM D323 IP 69 BS 2000 Part 69 A range of Bourdon Tube type pressure gauges with 150mm diameter mirror band dials to eliminate paralax errors while reading The Pressures up to 700kPa 100psi graduations are marked in kPa and psi Ibf in Accuracy 1 fsd The gauges have a bottom entry inch BSP fitting and a heavy duty 150mm dial stainless steel case with a large carrying handle suitable for lifting a e le in kP dus complete pressure vessel assembly from a bath The gauges conform to EN 837 S2 Accuracy Class 1 1 fsd inch BSP fitting Sturdy handle SETA REID VAPOUR PRESSURE GAUGES Scale Range Division Sub Division kPa psi kPa i kPa 0 to 35 0to 5 5 0 5 7 CALIBRATION CERTIFICATE WORKS to 100 Oto 15 10 0 5 0 to 200 0 to 30 25 1 0 to 300 0 to 45 25 1 0 to 400 0 to 60 50 1 5 0 to 700 0 to 100 22510 0 RVP VERIFICATION INSTRUMENTS 22430 3 SETA PRE PRESSURISED MANOMETER Verification of pressure gauge up to 135kPa 19 5psi e 0 2kPa graduations Mercury type unbreakable plastic construction wall mounting SUPPLIED WITH needle valve isolation
366. on to a personal computer The machined aluminium base is fitted with a flexible light with dimmer switch and a spirit level The counterbalanced head has a geared two 17500 0 Cone and container supplied separately speed raising and lowering mechanism and contains the control circuits SPECIFICATIONS keypad and fluorescent display The head may be rotated through 180 SUPPLIED WITH 47 59 plunger 50g and 100g plunger weights mains oe ewe e lead and instruction manual Penetration Time 1 to 9999 seconds fully variable Retention Release Display Digit Fluorescent as CALIBRATION amp VERIFICATION MATERIALS Voltage 110 120V or 220 240V 50 60Hz switchable Power 40W SETAPLUS EXTENDED WARRANTY AVAILABLE Size HxWxD Weight 12 5kg 17190 2 SETA UNIVERSAL PENETROMETER WITH INTEGRAL CONTROLLER Penetration range 0 to 400 Pen 40mm 5 8 10 12 30 and 60 second timer settings Solid state timer Automatic plunger release and retention Flexi light A semi automatic penetrometer with a range of 0 to 40mm 400 Pen Plunger release and retention is controlled by a solid state timer which can be set for penetration times of 5 8 10 12 30 and 60 seconds The head is fitted with a two speed elevating mechanism for quick and precise positioning of the p
367. p 195 BS 7392 ISO 918 ISO 3405 DIN 51 751 NF M07 002 JIS K2254 Equivalent to ASTM 7C F or 8C F thermometers 28 x 100 reading memory Selectable barometric correction mode Remote button Final boiling point detection and loss correction Absolute or simulated ASTM temperatures Automatic temperature probe calibration Pressure calibration facility RS232 RS485 and printer ports CALIBRATION CERTIFICATE WORKS OPTIONAL CALIBRATION CERTIFICATE UKAS Fully automated operation True volume measurement no correction factoring Programmable with learn feature Temperature probes with built in calibration data Dynamic ASTM 7C F and ASTM 8C F thermometer simulation Final boiling point detection and loss correction Dry point determination Automatic barometric pressure correction Independant temperature control of distillation flask condenser and receiver No refrigerants or liquid coolants Peltier cell cooled Solid State condenser module Peltier cell cooled receiver compartment Stand alone or PC operated RS232 5485 and printer ports LIMS compatible e LIMS compatible Software available for data logging and instrument control A programmable fully automated self contained distillation unit designed and manufactured by Orbis BV featuring the unique liquid refrigerant free Solid State condenser and cooled receiver compartment Distillation programs comprising temper
368. peration Ideal for monitoring residual fuel blends cargoes amp products in the distribution system Critical Measurement method for Product Safety and Release The H S Analyser was developed with Lloyd s Register s Fuel Oil Bunker Analysis and Advisory Service FOBAS along with support of other major international oil companies to provide users with a simple to use instrument patent applied for 5 is efficiently purged from the test sample by a combination of heat and agitation and is measured by a 5 specific detector No costly chemicals are required and eliminates the SA4000 0 need for analytical preparation by an expert chemist The instrument also has the capability with advice from SetaAnalytics to measure certain crude oil and other distillate products The 25 Analyser provides an industry approved test for supporting quality control and safety to ensure product is within specification It is also suitable for remediation treatment by assisting to quantify ACCESSORIES H S Analyser scavenger dosing levels for both feedstock components and finished products SA4001 0 H S STATIC CALIBRATION KIT SA4003 0 START UP KIT for approximately 20 tests comprising 5 test vessels 500ml diluent 20 disposable syringes and 2m silicone tubing E TECHNICAL DATASHEETS AVAILABLE ADTIONIA SA4000 001 CALIBRATED SENSOR JF EUITIUATIUNS A4002 0 PERSONAL PROTECTOR
369. poutless Beaker 600ml pack of 5 dpa ie 5 p 13730 005 Silicone Rubber Tube 4 metres th i 10200 005 Spoutless Beaker 600ml pack of 5 13800 003 Th ter Cli 10160 0 Glassware for Aniline Point Methods 93 11600 001 Brass pack of 5 s er Ullp 10160 001 Iron Wire Stirrer amp Cork 11600 002 Sleeve and Case pack of 2 1 B T 10400 0 Smoke Point Apparatus 20 11600 003 Thermometer IP40C with Sleeve amp Case 19811 002 Test Applicator 10400 001 Candle 11600 004 Thermometer IP41C with Sleeve amp Case 13661 3 Pensky Martens Closed Cup Tester 18 10400 002 Wick pack of 100 11600 005 Boiling Tube pack of 10 11870 001 Heat Controller 10400 003 Lamp Glass Locking Ring 11610 0 Pharmacopoeia Drop Point Apparatus 55 aa Test 7 10400 004 Wick Tube Assembly 11610 001 Thermometer Sleeve amp Case ee ae hi 10425 0 Wick Extraction Apparatus 20 11610 002 Cup Brass pack of 5 13661 002 ien riens oa LL 10425 001 Soxhlet Extractor 11610 003 Beaker Spoutless 1 litre pack of 5 13661 003 Lid Shutter St iden 21200 001 Condenser pack of 2 11610 004 Boiling Tube pack of 10 see l OND Glass Fask animl 11700 0 Lubricating Drop Point Apparat gvropreint5ppareun 13661 303 Lid amp Shutter 10510 0 Adlake Burning Test Lamp 21 10200 005 Beaker Spoutless 600ml pack of 5 13730 005 Silicone Rubber Tube 4 metres 10510 001 Glass Chimney pack of 6 11700 001 Brass pack of 5 22100 002 Gasket pack of 10 10510
370. provision for a temperature probe The lid of the sample cup is equipped with a stirrer sliding shutter and ports for the flash detector and sample temperature probe The DIPS pod contains a stirrer drive shutter actuator and ignitor dipping mechanism with a coaxial gas jet electric hot wire ignitor The outer bath inner bath and sample temperature probes are class A PRTs and flash detection is by a thermocouple Safety features include an initial dip to check that the sample is below its flash point at the start of the test and PRT checks to ensure that the correct probes are connected and are immersed in bath liquids or sample When in search mode the software limits the maximum temperature to 50 C above expected flash An over temperature cut out is mounted on the base flange of the outer bath SUPPLIED WITH DIPS pod Test Area Ignitor Flash Detector Inner and Outer Bath PRTs Sample interconnection leads instruction manual Note 34000 0 Universal Base Unit and 34008 0 Cooling Boost Module are required for operation Sub ambient tests down to 5 C require a 34006 0 Cryostat Method Abel Closed Cup Tests Equilibrium Non Equilibrium Flash No Flash Temperature Range Ambient to 93 5 C to 93 C with optional cryostat Barometric Correction Automatic Bath Liquid Liquid Heating Hot Plate Post Test Cooling Fan assisted or Circulating liquid external cryostat optional
371. pump and an efficient pulse damper provides smooth and continuous flow The pressure and temperature of the fuel are continuously monitored while it is pumped through the specified filter into the waste container The recorded pressure rise or the volume of pumped sample that causes a specified pressure to be exceeded are used by the microprocessor to calculate the test result Standard tests use 300ml of fuel pumped at 20ml min Verification and re calibration is simple and secure SUPPLIED WITH mains lead and instruction manual BIO FUEL TESTING SETALERT COMPATIBLE De 4 TECHNICAL DATASHEETS AVAILABLE Particulates Residues amp Composition FILTRATION TESTS 91600 3 Filter blocking tendency range Filterability quality factor FOF range Maximum pressure Voltage Size HxWxD Weight 91615 0 91616 0 91635 0 00100 0 81002 2 91640 0 91645 0 91650 0 22750 2 91660 0 91662 0 99922 0 81002 201 91615 001 91616 001 91635 001 CONSUMABLES Multi Filtration Tester manus Ew 1 0 to 30 low number is best 100 to 1 high number is best 200kPa 500W 110 120V 50 60Hz 220 240V 50 60Hz switchable 27 x 43 x 26cm 10kg ACCESSORIES Multi Filtration Tester E START UP KIT PROCEDURE A comprises filter holder tweezers 100 1 6um filters amp exit tubing OR START UP KIT PROCEDURE B comprises adaptor 1 6um encapsulated
372. r Drive Shaft amp Keys Worker Plate Churn Plate Water Bath Fuse pack of 5 Heater Stirrer Motor Power PCB Display PCB Temperature Probe Roll Stability Tester PRT Probe Motor amp Fan Drive Belt Roller Motor amp Gearbox Collar amp Bearing pack of 8 Thermometer Collar pack of 2 Rings pack of 12 Cylinder Cylinder Gasket pack of 30 Water Washout Tester Drive Belt Motor Pump Temperature Controller Probe Assembly Tubing Filtration Kit Filter 0 8 micron 47mm diameter pack of 100 Vacuum Filtering Flask SSAFLAB Filtration Kit Filters matched weight pairs 0 8 micron 47mm diameter Vacuum Filtering Flask Filter Holder 47mm Forceps Solvent Dispenser Petrislide Filtration Kit Filter 0 8 micron 47mm diameter pack of 100 4 Ball Lubricant Tester Test Balls pack of 1200 Safety Ring Cam Spindle Socket pack of 2 Nut Locking Ring Locking Ring Bearing Plate Disc Plunger Head Bearing Plug Bearing Pin Retaining Plate Vee Block Matched Pair Knife Edge Bearing Lever Arm Thrust Race Plunger Head Thrust Race Bearing Hub Ball Race Bearing Hub set of 2 Sliding Cursor Set of Weights Ball Chuck Torque Arm with Holding Ring Bearing Hub amp Ball Holder Housing Ball Race Shear Stability Head Test Bearing 4 Ball EP Lubricant Tester with Autoload Test Balls pack of 1200 Safety Ring Cam Spindle Socket pack of 2 Page 62 62
373. r REQUIRED 22422 6 VACUUM PUMP for details see page 136 OPTIONAL 80003 0 TRANSFORMER for use where electrical supply falls below 105V 80004 0 VACUUM PUMP for details see page 136 80009 0 SYRINGE 1ml c w LeurLock and needle 93700 2 LABORATORY REFRIGERATOR for details see page 140 CALIBRATION VERIFICATION amp TRAINING 80005 2 PRESSURE CALIBRATOR recommended for recalibrating when testing above 200kPa for details see page 25 MCLEOD GAUGE for details see page 146 PORTABLE DIGITAL BAROMETER 75 to 115kPa absolute for details see page 145 DIGITAL THERMOMETER for details see page 130 80007 3 99910 0 99922 0 Mini Method Vapour Pressure 81000 2 SETAVAP 2 ASTM 05191 IP 394 IP 409 37 8 C IP 481 EN 13016 1 EN 13016 2 37 8 C Correlates with D323 D4953 D5482 D6378 IP 69 IP 402 obs ISO 3007 EN 12 obs JIS K2258 NF M07 079 Rapid automatic vapour pressure testing Automatic drain and purge Mini method uses only 3ml sample size Selectable units kPa or psi Results available as Ptot DVPE EPA Crude Pabs Audible and on screen prompts RS232 interface The Setavap 2 is an automated instrument for the measurement of the vapour pressure of gasoline solvents light crude oils and other similar products using the Mini test method Fully evacuated chamber technology guarantees that the sample is tested under a full vacuum as required by the Mini test m
374. r 0 to 30 0 to 30 ASTM D1209 05386 Pt Co Hazen APHA 0 to 500mg Pt l 0 to 500mg Pt l Clear Liquids Solvents petroleum spirits water ASTM D1544 D6166 Gardner Colour 1 to 18 Units 1 to 18 Units Pale Yellow to Red Liquids Resins varnishes fatty acids R amp Y 0to70 B 0 to 40 Lovibond RYBN N 0to 3 9 ASTM E308 CIE Values Defined by spectrum locus Transmittance 0 to 10096 0 to 10096 Full spectrum and specified wavelengths iig gun Optical density 01025 0 to 2 5 Full spectrum and specified wavelengths Colorimeters amp Chromometers Colour mm SPECIFICATIONS Repeatability Chromaticity x y 30 0004 Transmittance 0 5 Saybolt Values i Observers 2 10 DN meraes un Dinar Keypad 23 key membrane keypad washable polyester with audible feedback 9languages English French German Italian Spanish Portuguese Russian Chinese and Japanese Size HxWxD 17 x20 x 44cm 17 x 52 x 20cm w m ACCESSORIES Seta Colorimeters OPTIONAL Multicolour Automatic 15262 0 GARDNER COLOUR SCALE CALIBRATION VERIFICATION amp TRAINING Multicolour Auto CALIBRATION VERIFICATION amp TRAINING High Precision SETA CERTIFIED COLOUR STANDARDS for details see page 114 15301 0 ASTM COLOUR CONFORMANCE FILTERS set of 3 for details see page 114 SAYBOLT COLOUR CONFORMANCE FILTERS set of 5 for details see page 114 153
375. r ASTM6F IP2F Pre conditioning to ASTM 097 for fuel oils heavy lubricant base stock and products containing residual fuel components ASTM 61C IP63C or ASTM 61F Note One thermometer is required for each test jar in simultaneous use in addition to the supplied compartment thermometer 11010 2 OPTIONAL Thermometers supplied separately 11500 0 COPPER CORROSION TEST VESSEL for ASTM D5853 stainless steel O ring sealed screw top closure Max pressure 700kPa 100 psi CALIBRATION VERIFICATION amp TRAINING 99851 0 MULTI TEST VERIFICATION MATERIAL ASTM 02500 IP 219 ASTM D6371 IP 309 Gas Oil EN 116 for details see page 150 99852 0 MULTI TEST VERIFICATION MATERIAL ASTM D97 IP 15 Fuel Oil SPECIFICATIONS for details see page 151 Temperature Range go ec 99853 0 MULTI TEST VERIFICATION MATERIAL ASTM D97 IP 15 Lubricating Oil g E to 69 C 99908 0 BIO MULTI TEST VERIFICATION MATERIAL Gas Oil 17 x 32x 18cm for details see page 151 44 0 1932 564391 LF 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk 51 Cold Flow amp Freezing Point Cold Filter Plugging Point 99000 2 COLD FILTER PLUGGING POINT APPARATUS ASTM D6371 IP 309 BS 2000 Part 309 BS 6188 EN 116 NF 116 Determines low temperature flow characteristics of diesel fuels gas oils and other distillate fuels Compatible
376. r LPG 10750 0 SETA BURNER for natural gas DISTILLATION FLASKS FLASK STOPPERS FLASK SUPPORT BOARDS amp RECEIVERS Refer to tables on this page THERMOMETERS ASTM2C 3C 7C 8C 37C 38C 39C 40C 41C 42C 102C 103C 104C 105C 106C 107C or BS 593 100mm immersion ASTM38C IP78C and ASTM40C IP80C for BS 658 only Note Other items which may be required include Petrolem spirit 60 80 Receiver cooling apparatus XU y D zl NA UFIIUNAL 11869 0 D86 DISTILLATION KIT Groups 1 to 4 comprising 125ml NS 19 26 Distillation Flask NS 19 26 Thermometer centering device Flexible Stopper Caps for side arm x 5 100ml Receiver 38mm Flask Support Board 50mm Flask Support Board 50 ASTM7C Thermometer ASTM8C Thermometer Condenser Cleaning Tool Boiling Stones 11866 0 SETA ANTI SPLASH PLATE for 100ml receiver pack of 3 99910 0 PORTABLE DIGITAL BAROMETER 750 to 1150 mbar absolute for details see page 145 CALIBRATION VERIFICATION amp TRAINING 99850 0 MULTI TEST VERIFICATION MATERIAL Kerosine for details see page 150 99851 0 MULTI TEST VERIFICATION MATERIAL Gas Oil for details see page 150 99854 0 MULTI TEST VERIFICATION MATERIAL Motor Gasoline for details see page 151 99908 0 BIO MULTI TEST VERIFICATION MATERIAL Gas Oil for details see page 151 SETA CERAMIC GLASS FLASK SUPPORT B ARDS
377. r Plate Worker Plate 51 x 1 4 inch holes Optional Churn Plate 270 x 1 16 inch holes 18150 0 SETA CUTTER FOR BLOCK GREASES comprises a guillotine blade fitted to c 4 a wood block mounted on a cast iron base Grease Pot 1 x Brass Optional Stainless Steel 18160 0 SETA CENTRALISING COVER Size HxWxD 32 x 16 x 16cm Weight 6kg Grease Workers amp Roll Stability Penetration ROLL STABILITY TESTER 19400 3 SETA ROLL STABILITY TESTER ASTM D1831 MIL G 10924 10rev min and 165 rev min Air bath temperature range ambient to 150 C Integral timer Four test cylinder capacity Simulates the effect of squeezing grease between the rollers and the outer race of a roller bearing The Seta Roll Stability Tester allows up to four test cylinders to be used simultaneously Each test cylinder contains a heavy roller and is loaded with a quantity of the sample grease The test cylinder rests horizontally upon a Set of driving and guide wheels which rotate the cylinder at either 10 or 165 rev min A digitally controlled fan assisted air bath is closed over the cylinders to provide evenly distributed heating up to 150 C and an integral timer is used to set the test duration SUPPLIED WITH mains lead and instruction manual Note Cylinders and Rollers supplied separately 19400 3 CALIBRATION amp VERIFICATION MATERIALS
378. r line pressure using the optional pressure reducing system An integral pump automatically draws the sample through an internal measuring chamber removing the need for an external sampling pump avcount is fully automatic once the test sequence is started The instrument flushes the cell with sample prior to commencing the measurements precise volume of sample is then analysed The flushing sample analysing sequences are automatically repeated in accordance with the selected test method Results are displayed on the LCD screen in real time and printed out on the integral printer as the test progresses The results are shown for 6 particle size bands in Particles ml and ISO Code Results can be saved to memory for trend analysis of samples printed out on the integral printer or downloaded to a PC or external printer The Log and Show software option allows data to be downloaded from the instrument to a PC in different formats and allows the instrument to be fuly controlled and configured from any Windows interface ACCESSORIES AvCOUNT PARTICLE COUNTERS SA1002 0 FLIGHT CASE SA1000 0 amp SA12000 0 SA1003 0 PC SOFTWARE SA1000 0 amp SA12000 0 SA1024 0 FLIGHT CASE SA1000 2 SA1026 0 PC SOFTWARE SA1000 2 SA1004 0 250ml BOTTLES AND CAPS pack of 30 SA1005 0 CONTAINER SAMPLING KIT 51mm bung SA1008 0 HIGH PRESSURE ADAPTOR for sampling at up to 315 bar Factory option SA1010 0 BOTTLE TUMBLER fitted with holder for 2
379. rature range Size Wa Weight SETA WATER WASHOUT TESTER ASTM D1264 IP 215 ISO 11009 DIN 51 807 FTM 791 3252 Bearing speed and water flow fine adjustment Jet bypass switch for pre heat re circulation Easy access drain valve The test bearing is mounted on a hub and rotated by an electric motor and toothed belt at 600 rev min A peristaltic pump draws heated water from the tank through a filter and sprays it a 1mm capillary onto the face of the bearing at a rate of 300ml min The temperature of the water is digitally controlled in the range of ambient to 80 C The water containing washed out grease is collected in the tank filtered and recycled A drain tap allows the tank to be emptied at the end of test The front panel has controls for water temperature fine adjustment of water flow rate and bearing rotational speed and a jet bypass switch to allow pre heated water to circulate without passing through the jet SUPPLIED WITH a test bearing for laboratory commissioning 5 32 inch and 2 5mm Allen key screwdrivers and instruction manual CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE SPECIFICATIONS Bearing rotational speed 600 30 rev min T50ml Ambient to 80 Tank capacity Temperature range Water flowrate Bml sec Voltage 110 120V or 220 240V 50 60Hz switchable Power 600W
380. rature range ad Flash point test in less than 2 minutes Small sample size 2 or 4ml Automatic flash detection Electronic peltier cooling Audible and on screen prompts Portable operation C or F display m Active Cool is the latest instrument in the Setaflash Series 3 range It has been designed to rapidly and efficiently carry out Flash No Flash tests and to determine the flash point of liquids and semi solids in the 10 to 130 C 50 to 266 F temperature range When used in Ramp mode the temperature of the sample increases at a rate of 2 C min An audible prompt to carry out a flash test occurs every 1 C rise up to 100 C every 2 C rise above 100 C until a flash is detected allowing rapid determination of a flash point in accordance with ASTM D7236 and IP 534 The sample cup is heated cooled by peltier cells This gives very accurate and stable sub ambient test temperatures and the benefit of rapid temperature normalisation between tests All functions are accessed via a two button keypad and the Seta Multifunctional And Rotational Test SMART control feature The digital display shows test parameters instrument status and the test result An audible prompt is sounded when an action is required from the operator Gas for the test jet shutter assembly is supplied from an integral gas tank which is filled using a standard butane lighter refill cartridge The automatic flash detection system is tuned to ignore halo
381. red for ASTM D2272 15240 0 SETA KEY for removing heater element from bath 99100 2 ANALYTICAL BALANCE for details see page 141 Note Required for ASTM D2272 CONSUMABLES ROBOT BATH 15200 308 NYLON BEARING 2 1 15210 4017 D RING SEAL pack Of lo 1 44 0 1932 564391 F 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk Oxidation Stability Oxidation 15205 2 15230 2 SETA AUTORGBOT PRESSURE MONITORING SYSTEM ASTM D2112 D2272 D4742 IP 229 Automatic pressure monitoring Real time graphical display Auto end point detection Simultaneous testing on two vessels Pressure range 0 to 1380kPa 0 to 200psi For use with the Seta ROBOT Bath 15200 5 to provide two independent channels of automated pressure monitoring and end point detection A self powered module and pressure transducer is mounted on each test vessel Data is transferred between the rotating and static elements by 15205 2 in situ an internal infra red link Signals from each module are fed into the dual channel pressure monitoring module mounted in the bath cabinet The output can be downloaded to an IBM compatible personal computer via the RS232 port for data logging and to give real time graphical data output The specially developed Seta ROBOT Software allows a choice of a NL five maximum test durations 12 24 48 96 and 192 hours SU
382. ressure kPa or psi User selectable better than 0 01kPa abs 110 120V or 220 240V 50 60Hz switchable Power 70W Vacuum Requirement Voltage 81000 2 Test Sequence 81000 2 with 81003 0 9 CALIBRATION amp VERIFICATION MATERIALS f gt gt E SETALERT COMPATIBLE SETAPLUS EXTENDED WARRANTY AVAILABLE TECHNICAL DATASHEETS AVAILABLE ACCESSORIES Setavap 2 REQUIRED 22422 6 VACUUM PUMP 22420 033 SEPTUM pack of 250 1 required per test 81003 0 SYRINGE 5ml and needles OPTIONAL 80004 0 VACUUM PUMP for details see page 136 81002 2 PRINTER 93700 2 LABORATORY REFRIGERATOR for details see page 140 45000 0 SETAPLUS EXTENDED 12 MONTH WARRANTY CALIBRATION VERIFICATION amp TRAINING 80007 3 MCLEOD GAUGE for details see page 146 80008 0 DIGITAL VACUUM GAUGE for details see page 148 99910 0 PORTABLE DIGITAL BAROMETER 75 to 115kPa absolute for details see page 145 99922 0 DIGITAL THERMOMETER for details see page 130 CONSUMABLES Setavap 2 2 Years 2000 Tests 22420 033 SEPTUM pack of 250 81003 0 SYRINGE 5ml and needles 81003 001 SYRINGE 5ml c w LeurLock 81003 002 NEEDLE for 81003 001 pack of 2 Vapour Pressure Wet Method REID VAPOUR PRESSURE RVP VAPOUR PRESSURE RVP 22210 3 TN T 22210 3 SETA REID VAPOUR PRESSURE BATH ASTM D323 Procedures A C amp D D1267 D4953 Pr
383. rinter Precise and reliable results In line side stream tests up to 10bar 310 bar option Rugged case for laboratory or portable field use On Site calibration BIO FUEL TESTING OPTIONAL SOFTWARE AVAILABLE i TECHNICAL DATASHEETS AVAILABLE SA1000 0 Particulates The potential for particulate dirt contamination in the fuel supply and distribution systems is a major concern particularly from Refinery Processing Materials Corrosion amp Rust in Pipes and Tanks Airborne Solids Degraded amp Damaged Hoses and Filters Microbiological Growth A rugged and portable laser based particle counter for checking and maintaining the quality of fuel throughout the distribution network Optimised for measuring particulate content in the range of 4um to gt 70ym diameter in Aviation Jet Turbine Fuels AvTur vcount is also suitable for testing biofuels and biofuel blends heating oil gas oil diesel automotive and marine gasoline and kerosines The svcount uses the light obscuration principle where the fluid under test is passed through a cell comprising a laser and a calibrated sensor Particles in the fluid cast a shadow onto the sensor which determines the area diameter and number of particles in the sample Sampling and measurement is simple fuel is drawn from a sample container or directly from the supply line vcount has a 10 bar standard pressure rating or can sample up to 315 ba
384. rogrammable filters and 1 an RS232 Interface k IE eS SUPPLIED WITH mains lead and instruction manual O CALIBRATION CERTIFICATE WORKS 99100 2 1g to 200g GRAM WEIGHT SET Set of 11 weights Weight mg Material Densi kg dm 1g 0 030 Stainless steel non magnetic 8 0 SUPPLIED WITH storage case and pair of 2g 2x 0 040 Stainless steel non magnetic 8 0 handling tweezers 5g 0 050 Stainless steel non magnetic 8 0 10g 0 060 Stainless steel non magnetic 8 0 209 2x 0 080 Stainless steel non magnetic 8 0 50g 0 10 Stainless steel non magnetic 8 0 lt CALIBRATION CERTIFICATE UKAS 100g 0 15 X Stainless steel non magnetic 8 0 12009 2x 0 30 Stainless steel non magnetic 8 0 99120 0 MILLIGRAM CALIBRATION WEIGHT SET 1mgto 500mg FRACTIONAL WEIGHT SET i Weight mg Material Densi Setof 12 weights ear 1mg 0 006 Aluminium 2 SUPPLIED WITH storage case and pair of m 2x omg uminium 10mg 0 008 Aluminium 2 7 20mg 2x 0 010 2 7 99120 0 50mg 0012 Aluminium 27 CALIBRATION CERTIFICATE UKAS 100mg 0 015 Nickel Silver 8 7 b 200mg 2x 0 020 Nickel Silver 8 7 500mg 0 025 Nickel Silver EN Verification of rotational speed SPECIFICATIONS Range 5 to 9999 RPM 0 0595 1 digit Hand held optical tachometer with quartz PET VET NEUES crystal
385. roviding additional insulation The bath is illuminated via integral diffuse back lighting SUPPLIED WITH mains lead and instruction manual BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS 94710 2 Viscometers supplied separately OD 94700 2 KV 4 LOW TEMPERATURE VISCOSITY BATH ASTM D445 D446 IP 71 BS 188 BS 2000 Part 71 ISO 3104 ISO 3105 DIN 51 561 NF T60 100 FTM 791 305 JIS K2283 Extended temperature range 60 C to 15 C Suitable for lubricants and JP 10 jet turbine fuels Accommodates up to 4 standard viscometer tubes Twin compressor cooling system Fluorescent backlighting Fan to reduce condensation on viewing window A low temperature bench top kinematic viscometer bath with integral refrigeration that can accommodate up to 4 viscometer tubes Cooling is by two air cooled compressors giving a temperature range of 15 to 60 C digitally controlled to within 0 05 C The bath jar is an unsilvered dewar type and is illuminated via back lighting A fan is fitted to reduce condensation on the viewing window SUPPLIED WITH mains lead and instruction manual BIO FUEL TESTING cu 94700 2 Viscometers supplied separately CALIBRATION amp VERIFICATION MATERIALS S 9 SPECIFICATIONS Seta Part No 94710 2 94700 2 40 to 20 C 60 to 15 C 0 015 20 C 0 05 C 0 01 40 C Temperature Range Temperature Stability wo am Methyl Alcohol or Methyl Alcohol or Dena
386. rrying handle to support Effusiometer when L the gases INES THERMOMETERS IP39F or IP39C SUPPLIED WITH instruction manual 97320 0 EE Effusiometer 97300 004 RUBBER RING Fac CC Dem M M aa c 1 97300 005 GLASSWARE SEAL RING pack 5 1 97310 0 97500 0 FREEZE VALVE 97500 0 22110 0 DRYNESS TESTER 22110 0 22120 3 DEW POINT APPARATUS 22120 3 Thermometer supplied separately 22130 2 22130 2 Water Vapour Content ASTM D2713 IP 395 ISO 13758 Moisture test for propane type LPG Standard gas bottle connection Particle filter A go no go tester for water vapour content in propane type LPG The time taken for an orifice to block with ice when LPG flows through it at normal vapour pressure gives an indication of the tendency for malfunction in pressure reduction systems The valve has two operating positions full flow for chilling purging and restricted flow for testing and Is fitted with a particle filter Suitable for standard gas bottle connection SUPPLIED WITH carry case and instruction manual GPA 2140 The 22110 0 Dryness Tester gives an indication of the dryness of Commercial Propane and Propane HD5 by colorimetric indication The tester comprises inlet valve cooling coil capillary orifice glass tube metal shield protective caps and pressure gauge 0 to 4 bar 0 to 60 psi In operatio
387. s CDERICICATINNIC V rE C L Al 10 N JJ Maximum Relative Centrifugal Force RCF 22149 Maximum Rotational Speed 3000 rev min Temperature Range 30 to 80 C switchable F 1 C at 60 C Timer Range 10 sec to 100 hours or continuous f operation E Control Microprocessor with 99 memory capacity Capacity 4 Samples Voltage range Optional transformer for 110 120V 220 240V 50 60Hz Power 950W Size HxWxD 40 1 x 56 4 x 63 9cm Weight 72 5kg Centrifuge Equipment CENTRIFUGE ACCESSORIES SETA No D91 D96 D893 01796 022738 D2709 D2711 D4007 05546 ACCESSORIES Oil Test Centrifuge 90040 0 e e Refer to the table of ITEMS REQUIRED FOR EACH TEST and select from the 30060 0 e following options 90011 0 90001 2 ADAPTOR for 90040 0 90060 glassware pack of 4 90012 0 e 90003 2 ADAPTOR for 90050 0 glassware pack of 4 90010 0 90005 2 ADAPTOR for 90011 0 glassware pack of 4 30001 2 e 2 d 90002
388. s OPTIONAL 99200 2 99205 0 LABORATORY OVEN for details see page 137 DESSICATOR 200ml and Disc for details see page 137 Note Other items which may be required include Toluene and Anhydrous methyl alcohol a SPECIFICATIONS Voltage 110 120V 50 60Hz 220 240V 50 60Hz i TECHNICAL DATASHEETS AVAILABLE 10425 0 Burning Rate Flash Point Smoke Point amp Sustained Burning ADLAKE BURNING TEST BURNING TEST 10510 0 10500 0 26500 0 SETA ADLAKE BURNING TEST LAMP ASTM D187 IP 10 BS 2000 Part 10 FTM 791 2106 Provides information on the burning properties SPECIFICATIONS of kerosine particularly for illumination SPECIFICATIONS Comprising a fabricated sheet metal oil Size HWD SixXxlm reservoir brass burner glass chimney and wick Weight SUPPLIED WITH two spare chimneys and a pack of 10 certified wicks ACCESSORIES Smoke Point Apparatus REQUIRED 10500 0 SETA FLAME GAUGE for details see below OPTIONAL 99100 2 ANALYTICAL BALANCE for details see page 141 99200 2 LABORATORY OVEN for details see page 137 Note Other items which may be required include 19mm paraffin flat wicks de natured ethanol dilute hydrochloric acid and precipitation naphtha SETA FLAME GAUGE ASTM D187 A gauge for measuring the height and width SPECIFICATIONS of a flame Mounted on a tripod base and SPECIFICATIONS adjus
389. s EPA 1020 A amp B Classification of Dangerous Goods for Carriage Viscous and Non Viscous Liquids Ramp mode for ASTM D7236 amp IP 534 Flash point test in less than 2 minutes Small sample size 2 or 4ml Ambient to 300 C temperature range Automatic flash detection Audible and on screen prompts Portable operation Simple calibration 33000 0 Setaflash 3 is an easy to use instrument that can complete a flash no flash test in less than two minutes or determine the flash point of a sample within a temperature range of 0 to 300 C in typically 8 minutes All functions are accessed via a two button keypad and the Seta Multifunctional And Rotational Test SMART control feature The digital display shows test parameters instrument status and the test result An audible prompt is sounded when an action is required from the operator An automatic flash detector reduces the chance of mis interpretation of the test result by the operator and enhances repeatability The temperature ramp mode allows rapid determination of the flash point of a sample in accordance with ASTM D7236 and IP 534 The cup is heated at a rate of 2 C per minute from the start temperature An audible prompt to carry out a flash test occurs every 1 C rise up to 100 C every 2 C rise over 100 C For safety purposes if no flash is detected when the temperature reaches 40 C above the start temperature the flash tester automatically terminates the test A new higher s
390. s threaded to accept various pressure monitoring devices CALIBRATION CERTIFICATE WORKS 15200 5 shown with 15210 5 Oxidation Vessels and 15230 2 Digi corders installed ACCESSORIES RoBOT BATH 11470 0 SILICONE CARBIDE PAPER 100 grit FEPA 280 x 230mm pack of 50 15210 5 SETA ROBOT OXIDATION VESSEL for details see below 2 PRESSURE CERTIFICATE UKAS 15460 0 OXYGEN CHARGING AND PURGING KIT comprises oxygen charging lead and pressure gauge 16930 0 COPPER CATALYST WIRE 16 SWG for details see page 73 OR 16931 0 PREFORMED CATALYST COIL pre formed 16930 0 for details see page 73 OR 16932 0 CATALYST for details see page 73 Note for ASTM D4742 only 94632 0 SILICONE BATH OIL 20 litres for use at temperatures up to 150 C Note 4 required REAL TIME DIGITAL PRESSURE MONITORING 15205 2 SETA AUTOROBOT PRESSURE MONITORING SYSTEM for details see page 65 OR DIGITAL PRESSURE MONITORING 15230 2 SETA DIGI CORDER for details see page 65 Note 1 required for each pressure vessel THERMOMETERS ASTMS96C or IP37C 15211 3 SETA SPANNER AND BENCH PLATE for oxidation vessel 15220 0 SETA GLASS LINER AND PTFE COVER borosilicate glass with stainless steel springs Note 1 required for each pressure vessel 15215 0 VESSEL STEM GAUGE to measure run out on pressure vessel stem 15221 0 ACCESSORY KIT comprises sample container aluminium disc and cover with stainless steel springs Note Requi
391. sample size micro samples typically 0 25ml The sample volume required is dependent the tube constant and is pre determined at the time of tube manufacture For maximum accuracy and ease of handling it is recommended that samples are injected into the capillary using a positive displacement pipette 83545 3 with additional 83575 2 and Viscometer Tubes supplied separately BIO FUEL TESTING SOFTWARE INCLUDED CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE TECHNICAL DATASHEETS AVAILABLE SPECIFICATIONS Viscosity Range 2 5 to 2000 mm s Temperature Range Ambient to 150 C Temperature Stability 0 01 below 100 C 0 03 100 to 150 C Sample Size 0 15 to 0 275 ml J Typical Flow Time 50 to 100 seconds No of Baths 2 Bath Capacity i 2 litres up to 12 6 per bath 110 120V 50 60Hz 220 240V 50 60Hz switchable 800W Size HxWxD 68 x 59 x 37cm t Weight 40kg Tube Capacity AUTO DUPLEX VISCOMETER TUBES Each tube has two measuring bulbs upper and lower in series providing two measurements from a single sample injection This increases the overall capacity of the instrument to 24 simultaneous tests and provides a quick check of determinability 7 tubes are available covering the range 2 5 to 2000 mm s
392. se with 15550 2 and 11400 6 22190 0 CONFORMANCE CERTIFICATE WORKS 11440 0 CONFORMANCE CERTIFICATE WORKS ACCESSORIES Copper amp Silver Test Strips OPTIONAL 11241 0 SILICONE CARBIDE PAPER 105 150 grit FEPA 28 x 23cm pack of 50 11460 0 SILICONE CARBIDE PAPER 65um 240 grit FEPA 28 x 23cm pack of 50 11470 0 SILICONE CARBIDE PAPER 100 grit FEPA 28 x 23cm pack of 50 11480 0 SILICONE CARBIDE GRAINS 105um 150 mesh 500g pack 5 packs 11530 0 SETA MULTI STRIP VICE holds up to five strips while polishing Note Other items which may be required include Petroleum Spirit 40 60 Diethyl Ether Corrosion Corrosion amp Rust SILVER CORROSION IN GASOLINE CORROSION IN GASOLINE 11515 0 ASTM D4814 Annex IP PM DJ 2005 Complete kit for two test stations Silver test tokens included Test token preparation materials included 11515 0 components for 1 test position only SILVER CORROSION TEST KIT GASOLINE Note An ASTM12C thermometer and a corrosion bath are required CONFORMANCE CERTIFICATE WORKS CORROSION IN LPG IN LPG 22220 4 22150 5 SETA CORROSION TEST BATH Stainless steel water bath which accommodates up to 3 pressure vessels Fitted with heater and thermostatic temperature controller with integral circulator and LED display SUPPLIED WITH mains lead instruction manual and gabled stainless steel lid SPECIFICATIONS SiO
393. see page 145 99960 0 DIGITAL PHOTO TACHOMETER for details see page 147 CONSUMABLES Abel Closed Cup Module 34100 002 SAMPLE PRTPROBE n cm mo rn ey T 1 34200 0033 OUMER BATHIERIPROBES eee c ere ae n 1 3420000 65 O AXTABIGNEDUR 6625555 MN RU aa 2 34700 001 e EEASH DETECTOR npa nin 2 81002 001 PRINTER PAPER pack of 20 rolls 1 Flash Point Smoke Point amp Sustained Burning MODULAR FLASH POINT TESTER 34300 0 MULTIFLASH CLEVELAND OPEN CUP MODULE ASTM 092 IP 36 EN ISO 2592 BS 2000 Parts 36 amp 403 obs DIN 51 376 NF T60 119 JIS K2265 AASHTO T48 Flash Point amp Fire Point Flexible automated search mode Ambient to 400 C temperature range Gas or electric ignition Automatic snuffer Independent fire detector The Cleveland Open Cup Module comprises a Test Area DIPS pod Dipping Ignition Pilot Stirrer flash fire detector sample temperature probe and all necessary cables to interconnect with the 34000 0 Universal Base Unit The Test Area consists of a removeable sample cup in a thermal insulation ring and a probe block for mounting the flash fire detector and sample temperature probe The sample cup is heated by the hotplate within the 34000 0 Universal Base Unit The DIPS pod contains the ignitor sweeping mechanism with a coaxial gas jet electric hot wire ignitor and a snuffer that extinguishes any flames in the sample cup
394. sets of glassware are required for 12 test configuration 16771 0 GLASSWARE 39 x 210mm test cell assembly pack of 6 Note 16600 0 only 16840 0 GLASSWARE 27 x 300mm test cell assembly pack of 6 Note 2 sets of glassware are required for 12 test configuration 16850 0 GLASSWARE 39 x 300mm test cell assembly pack of 6 Note 16600 0 only 16860 0 GLASSWARE 51mm Allihn condensor assembly pack of 6 Note 16600 0 only 16601 2 FLOWMETER 1 0 I hr oxygen 2 fs set of 6 2 CALIBRATION CERTIFICATE WORKS 16602 2 FLOWMETER 3 0 I hr air 2 fs set of 6 CALIBRATION CERTIFICATE WORKS 16603 2 FLOWMETER 5 0 I hr air 2 fs set of 6 CALIBRATION CERTIFICATE WORKS 16608 0 FLOWMETER 15 I hr air 1 fs set of 6 CALIBRATION CERTIFICATE WORKS 16610 0 DIGITAL THERMOMETER with 30 and 100cm thermocouples 16780 0 IRON CATALYST WIRE 15m for details see page 73 16790 0 COPPER CATALYST WIRE 15m for details see page 73 16919 0 PREFORMED COPPER STEEL CATALYST COIL pack of 6 for details see page 73 16920 0 STEEL CATALYST WIRE 3m pack of 6 for details see page 73 16930 0 COPPER CATALYST WIRE 3m pack of 6 for details see page 73 16791 0 PREFORMED COPPER CATALYST COIL pack of 6 for details see page 73 16890 0 5 METAL SPECIMEN SET 16660 0 BUBBLE FLOWMETER 16730 0 BUBBLE FLOWMETER 22750 2 DIGITAL STOPWATCH hand held 0 1s resolution for details see page 141 THERMOMETERS ASTMS9C IP1
395. sity standards manufactured to ASTM D1840 SUPPLIED WITH filling tube luer adaptor density standards case instruction sheet CONFORMANCE CERTIFICATE UKAS DENSITY STANDARDS Vi CONFORMANCE CERTIFICATE ATEX CONSUMABLES Portable Density Measurement Kit 2 Years 2000 Tests 12600 001 DENSITY STANDARD 0 8720 20 C 100ml bottle 12600 002 DENSITY STANDARD 0 8540 20 C 100ml bottle 12600 003 DENSITY STANDARD 0 8200 20 C 100ml bottle 12600 0 SPECIFICATIONS 0 to 40 C 32 to 104 F Size HxWxD Mxi3x2 amp m Density Range Temperature Range Viscosity Range Density Temperature amp Fluid Density RELATIVE DENSITY DENSITY 97300 0 22100 0 22100 0 Pressure Gauge supplied separately k SCHILLING EFFUSIOMETER IP 59 Method C obs An instrument providing a rapid and convenient method for determining the density of a gas relative to air Based on the assumption that the times taken by equal volumes of gases under the same temperature and pressure to flow through a small orifice are proportional to the square roots of the densities of the gases SUPPLIED WITH instruction manual SPECIFICATIONS Size HxWxD 62x 80x 300m Weight CONSUMABLES Schilling Effusiometer 2 Years 2000 Tests 97300 004 RUBBER RING pack of 5 97300 005 GLASSWARE SEAL RING pack of 5 SETA PRESSURE HYDROMETER APPARATUS ASTM D1657 obs IP 59 Method
396. ssel 15810 0 SETA LINER borosilicate glass with cover pack of 3 AUTOMATIC PRESSURE MONITORING 15450 5 SETA AUTO OXIDATION CONTROL UNIT for details see page 67 OR ENHANCED ANALOGUE PRESSURE MONITORING 15611 2 PORTABLE CAMBRIDGE PRESSURE RECORDER for details see page 67 OR ANALOGUE PRESSURE MONITORING 15600 0 SETA PRESSURE GAUGE for details see page 67 THERMOMETERS ASTM22C IP24C or ASTM22F IP24F Note Other items which may be required include Solvents Filtering crucible Oxygen 15650 0 WATER PURIFIER to minimise scale production Suitable for domestic water supply 60l hr max flow Comprises disposable cartridge with capacity for 960 litre soft water or 180 litre hard water 15800 4 SETA OXI FEED PRESSURE VESSEL a 15802 0 pressure vessel without a burst disc or discharge tube PRESSURE CERTIFICATE UKAS 99100 2 ANALYTICAL BALANCE for details see page 141 Note required for tests to D873 99200 2 LABORATORY OVEN for details see page 137 Seta Part No 1Vessel 2Vessels 3Vessels 4 Vessels AUTOMATIC PRESSURE MONITORING 15450 3 Seta Auto Oxidation Control Unit 1 1 1 1 ENHANCED ANALOGUE PRESSURE MONITORING 15611 2 Portable Cambridge Pressure Recorder 1 1 2 2 ANALOGUE PRESSURE MONITORING 15600 0 Seta Pressure Gauge 1 2 3 4 66 11 44 0 1932 564391 LF 44 0 1932 568363 sales stanhope seta co uk w www stanhope seta co uk 15450 3 15611 2 15600 0 SETA AUTO OXIDATION CONTROL UNIT
397. ssels five working and two sample pre heat positions in an oil bath The bath is heated to and maintained at any set temperature between 25 and 150 C The unit is a combined heater and re circulating pump with digital temperature control and display RS232 interface for connection to a personal computer and over temperature and low fluid level warning devices The stirrer head can be rotated over each test vessel in turn and is locked accurately in position by a detent pin The stirrer head houses a motor and variable speed controller with a range of 50 to 1800 rev min and a digital tachometer The stirrer control unit incorporates a digital timer and display and provides power to the stirrer head and the heater unit SUPPLIED WITH mains lead and instruction manual 96600 3 SPECIFICATIONS ACCESSORIES Herschel Emulsifier 220 240 50 2 94632 0 SILICONE OIL 20 litres for filling bath for use up to 150 C 1550W 110V version 94633 0 BATH OIL 20 litres for filling bath for use up to 100 C Size HxWxD 74 x 40 x 35cm 96511 0 GLASS CYLINDER borosilicate glass 100ml graduated 7 required Weight 1 THERMOMETERS ASTM 19C 19 21C 21F separation amp Evaporation Separation GREASE SEPARATION APPARATUS 20980 0 SETA GREASE SEPARATION APPARATUS ASTM D1742 FTM 791 322 Six cell capacity Comprises six pressure bleeding test cells Type B see Seta 20990 0 with combined rack and pressure ma
398. statistically significant number of laboratories to determine certified values Seta MTVMs are supplied in 500ml containers and have a 18 month validity from date of supply The following table lists the available MTVMs SETA MTVM KEROSINE 500ml SETA MTVM GAS OIL 500ml SETA MTVM FUEL OIL 500ml SETA MTVM LUBRICATING OIL 500ml SETA MTVM MOTOR GASOLINE 500ml SETA MTVM BITUMEN 250ml SETA BIO MTVM GAS OIL 500ml CONFORMANCE CERTIFICATE WORKS Cold Flow amp Freezing Point Cloud amp Pour Point REFRIGERATED CLOUD amp POUR POINT BATHS 93531 7 94100 3 ASTM D97 ASTM D2500 ASTM D5853 IP 15 IP 219 IP 441 BS 2000 Parts 15 amp 219 ISO 3015 ISO 3016 DIN 51 597 EN 23015 NF T60 105 FTM 791 201 JIS K2269 SPECIFICATIONS 3 1 low temperature a Individually temperature controlled compartments Two litre bath capacity in each compartment Four air wells in each compartment Compartment i i i Compartment Volume Two stage CFC free refrigeration system EMEN 2 litre Total Test Positions Three and four compartment refrigerated cloud and pour point baths Temperature Range Each 2 litre compartment is individually temperature controlled and can 16 Ambient to 35 C x3 35 C to 51 C x1 Ambient to 34 C accommodate four Air Wells Ambient Temp Range Note Du
399. supplied separately Note Glassware and catalysts must be ordered separately A BIO FUEL TESTING CALIBRATION CERTIFICATE WORKS Sp SETAPLUS EXTENDED WARRANTY AVAILABLE FOR ACCESSORIES SEE PAGE 72 A BIO FUEL TESTING S CALIBRATION CERTIFICATE WORKS SETAPLUS EXTENDED WARRANTY AVAILABLE FOR ACCESSORIES SEE PAGE 72 OXIDATION CATALYSTS Polished and cleaned prior to winding and encapsulation Sealed into a nitrogen filled container with dessicant bag SELECTION GUIDE STANDARD WIRE METHOD MATERIAL PRE FORMED COILS LENGTHS ASTM D943 Copper Steel 16921 0 16920 0 amp 16930 0 ASTM D2112 Copper 16931 0 16930 0 ASTM D2272 Copper 16931 0 16930 0 ASTM D2440 Copper 16791 0 ASTM D4310 Copper Steel 16921 0 16920 0 amp 16930 0 ASTM D5846 Copper Steel 16919 0 16920 0 amp 16930 0 IP 229 Copper 16931 0 16930 0 IP 306 Copper 16790 0 IP 307 Copper 16790 0 IP 331 Iron Steel 16780 0 amp 16790 0 IP 335 Copper 16790 0 BS 148 Copper 16790 0 150 4263 Copper Steel 16921 0 16920 0 amp 16930 0 DIN 51 587 Copper Steel 16921 0 16920 0 amp 16930 0 NF T60 150 Copper Steel 16921 0 16920 0 amp 16930 0 IEC 1125 A amp B Copper 16790 0 Corrosion amp Rust Corrosion Baths COPPER amp SILVER CORROSION BATHS amp SILVER CORROSION BATHS ASTM D130 D4048 D4814 Annex IP 112 IP 154 IP 227 obs IP PM DJ 2005 BS 2000 Parts 112 amp 154 DIN 51 811 EN 2160 791
400. support strut and carrying handle 14866 2 SAMPLING CANS ASTM D4057 D4306 IP 51 obs BS 3195 Part 1 DIN 51 750 ISO 3170 API 2546 NF M07 001 AP MPMS Chapter 8 Cork stopper fitted with metal washers and hook Weight enclosed in false bottom Heavy gauge wire handle with cable guide Perforated thermometer well on double wall model A series of simple and safe to use vessels to take samples from non pressurised bulk storage without contamination and transferring them to laboratory equipment The sample cans and fittings are manufactured from either copper tinned steel or for Jet Fuel use stainless steel A double wall sample can with a copper inner and a brass outer equipped with a perforated thermometer well is available for heated oil samples SINGLE WALL SAMPLING CANS Seta Part Capacity Material Diameter Length Neck Dia Weight inc handle internal 14710 0 500ml Copper 6 4cm 31cm 3 8cm 1 25kg 14730 0 500m Tinned Steel 6 4cm 32cm 3 8cm 1 4kg 14800 0 500ml Stainless Steel 6 4cm 31cm 3 8cm 1kg 14790 0 1 litre Copper 38 3cm 34cm 3 8cm 2kg 14700 0 1 litre Copper 8 3cm 35cm 3 8cm 2 5kg 14720 0 1 litre Tinned Steel 8 3cm 36cm 3 8cm 2 4kg 14801 0 1 litre Stainless Steel 8 3 36cm 3 8cm 2kg 14750 0 1 5 litre Copper 8 3cm 45cm 3 8cm 3kg 14802 0 2 litre Stainless Steel 8 3 63cm 3 8cm 2 5kg DOUBLE WALL SAMPLING CANS Seta Part Capacity Material Diameter Length Neck Dia Weight inc handle intern
401. t Shell Water Capsules offer detection to 30ppm 80 tests amp syringes Digicell Digital readout of Water content 100 3000ppm 200 10000pm and 0 10 50 tests SUPPLIED WITH syringes portable gas supply Shell water capsules CONSUMABLES Fuel Integrity Test Kit instruction manuals and carry case 86000 301 WATER IN OIL REAGENT 50 tests 86500 001 SHELL WATER CAPSULES pack of 160 86000 301 WATER IN OIL REAGENT pack A amp B 50 tests 86500 001 SHELL WATER CAPSULES pack of 160 VY VIV ATAR le ps Wwww stanho Particulates Residues amp Composition TEST KITS 86000 3 86200 0 86300 0 SETA PORTABLE OIL CONDITION TEST KIT Rapid go no go testing Ready to use Five simple to use tests Rugged fitted case A portable kit which allows rapid go no go checks on in service oils to evaluate degradation and contamination Suitable for lubricating oils crank case hydraulic gear turbine and compressor oils Water Content A digital test cell gives a numeric readout of water content when the sample is mixed with two reagents Total Base Number The same digital test cell will display the TBN when the sample is mixed with another reagent Salt Water Contamination A bottle of reagent and a pack of test pads that change colour in the presence of salt water are provided Insoluble Content A pack of blotter spot test sheets is included allowing visual determination of insoluble conte
402. t Plunger 15g 0 025g Use with 18060 0 Half Scale Cone 17950 0 SETA Ultra Light Weight Plunger 6 38g 0 025g Use with 17910 0 Quarter Scale Cone 17950 0 amp 17910 0 SETA PART DESCRIPTION METHOD ASTM D937 IP 179 BS 2000 Part 179 DIN 51 580 IS0 2137 FTMS 791 312 Brass 102mm dia 65mm deep water tight lid 18120 0 SETA Sample Container Petrolatum cylindrical with flat bottom For penetrations 200 and 350 69mm dia 18470 0 SETA Sample Container Bitumen amm RETE e etit ASTM D5 IP 49 BS 2000 Part 49 EN 1426 For penetrations below 200 55mm dia 18530 0 SETA Sample Container Bitumen 35mm deep pack of 50 ASTM D5 IP 49 BS 2000 Part 49 For penetrations below 40 33 50mm dia 8 16mm deep pack of 1000 For penetrations 200 and 350 55mm dia 55mm deep pack of 50 18535 0 SETA Sample Container Bitumen ASTM D5 18540 0 SETA Sample Container IP 49 ASTM D5 IP 49 BS 2000 Part 49 18570 0 SETA Slip Cover for 18530 0 For use with 18530 0 ASTM D5 IP 49 BS 2000 Part 49 18540 0 18530 0 Copper for transferring containers from 18550 0 SETA Transfer Dish water bath to penetrometer pack of 2 ASTM D5 IP 49 BS 2000 Part 49 For Bitumen For rapid quality control tests not 16300 USE Ne n Cup in compliance with the test methods listed 18480 0 SETA Test Specimen Container Wax Brass 25 4mm dia 31 8mm deep pack of 2 ASTM D1321 IP 376 DIN 51 579 18481 0 SETA Brass
403. t be a member of an inter laboratory correlation scheme Membership of the P Gasoline and diesel fuel engine correlation scheme enables laboratories to meet this requirement for both petrol and diesel fuel engines Samples of gasoline or reference blends are tested for both research and motor octane number and diesel fuel for cetane number Results are statistically analysed and published monthly enabling laboratories to compare their results with the statistical mean In addition a yearly results report is issued For further details of membership contact e cfrcs energyinst org IP Standard test methods IP Standard test methods STM is an essential part of any quality control regime for petroleum testing laboratories A necessary tool for the national and international testing of petroleum and petroleum products the 2010 version of IP Standard Test Methods also enables laboratories to provide evidence of compliance with the most up to date test methods during inspections STM can be purchased in book format as single PDFs or by subscription online To order the complete 3 volume set of IP Standard test methods for the analysis and testing of petroleum and related products and British Standards 2000 Parts including CD Rom or to order individual PDFs visit www energypublishing org IP Derived Cetane Number correlation scheme DCNCS This scheme is run parallel to and uses the same specially blended diesel fuels that are use
404. t required individual tubes are available as follows Seta Part No Nominal Constant Sample Volume ml Viscosity Range mm s 83600 001 0 01 0 1 3109 83600 002 0 03 0 15 6 to 18 83600 003 0 05 0 15 10 to 30 83600 004 0 1 0 175 20 to 60 83600 005 0 3 0 175 60 to 180 83600 006 0 5 0 225 100 to 300 83600 007 1 0 0 250 200 to 600 83600 008 3 0 0 250 600 to 1200 0 275 1000 to 2000 183600 009 a SETA KINEMATIC VISCOSITY BATH THERMOMETERS With ice point scale and 0 02 C subdivisions to allow easy reading to within 0 01 C CALIBRATION CERTIFICATE WORKS CALIBRATION CERTIFICATE UKAS OPTIONAL Seta Part No Seta Part No Temperature Temperature Works Cert UKAS Cert Set Point Range 183620 0 83620 07 40 38 6 to 41 4 183622 0 83622 0Z 50 48 6 to 51 4 83624 0 83624 07 100 98 6 101 4 183626 0 83626 0 150 148 6 151 4 83747 2 DIGITAL PIPETTE 50 250uL for transparent opaque liquids 83748 2 PIPETTE TIPS disposable pack of 200 94630 0 BATH OIL 5 litres for filling viscometer baths in the temperature range of ambient to 80 C AND OR 94634 0 BATH OIL 5 litres for filling viscometer baths in the temperature range of 80 to 120 C AND OR 94631 0 SILICONE BATH OIL 2 litres for filling viscometer baths in the temperature range of 100 to 150 C 83602 0 SETA BITUMEN KINEMATIC VISCOMETER TUBES Set of six covering 6 to 1800mm2 s Calibration based on a minimu
405. table test temperatures from ambient to 150 C 0 02 C up to100 C and 0 05 C between 100 and 150 C The bath is protected by low liquid level and overtemperature cut outs Equipped with a toughened glass front window easily accessible 84200 0 drain valve integral back lighting top plate provision for reference thermometer and attachments SUPPLIED WITH mains lead and instruction manual BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS Ambient to 150 C 0 02 up to 100 C 10 05 between 100 and 150 C 0 02 at 40 and 100 C Temperature Range Temperature Stability SETAPLUS EXTENDED WARRANTY AVAILABLE Temperature Uniformity OB 9 Tube pes TECHNICAL DATASHEETS AVAILABLE Bath Fluid Oil or Water Bath Capacity 50 Litres Voltage 220 240V 50 60Hz CONSUMABLES KV 6 Bath Size HxWxD 56 x 35 x 44cm meum zm 040040 2 6 ACCESSORIES KV 6 Bath ACCESSORIES Continued KINEMATIC VISCOMETER TUBES 23152 0 VISCOMETER HOLDER 11mm tube size for Ubbelholde amp suspended level Select from the tables on pages 40 to 42 viscometers SETA KINEMATIC VISCOSITY BATH THERMOMETERS 23154 0 VISCOMETER HOLDER 13mm tube size for Cannon Fenske viscometers With ice point scale and 0 02 C subdivisions to allow easy reading to within 0 01 C 23156 0 VISCOMETER HOLDER 15mm tube size for U tube reverse flow Q CALIBRATION CERTIFICATE WORKS Neco
406. table height support column Hinged and Size 35x25x25em adjustable with stops for true horizontal and vertical readings SUPPLIED WITH two spare chimneys and a pack of 10 certified wicks SETA BURNING RATE TEST RIG UN Class 4 Division 4 1 Burning Rate Test Method IATA Dangerous Goods Regulation Section 3 4 2 EPA 130 Health amp Safety Commission Carriage of Dangerous Goods by Road amp Rail 1994 Appendix D US Department of Transport CFR 40 173 Appendix E Classification of flammable solids SPECIFICATIONS se __ due K Laws governing the packaging and transport of dangerous goods require that substances are identified according to the nature of the potential hazard The Burning Rate Test Rig is used to determine the classification of flammable solids such as powders granules and pastes Comprising a mould supporting frame sample shovel tray with measuring rule conducting plate and duratec paper ACCESSORIES Burning Rate Test OPTIONAL 13802 0 SETA GAS BURNER universal for Natural methane Coal and Butane 22150 2 DIGITAL STOPWATCH for details see page 141 71001 0 SETA VENT for details see page 19 99900 0 SETA SAFETY SPECS pack of 4 for details see page 145 10510 0 10500 0 BURNING RATE TEST 26500 0 Vapour Pressure Mini Method rm ll SETAVAP ANALYSER ASTM D5188 D5191 IP 394 IP 409 EN 13016 1 EN 13016 2 3
407. tart temperature would have to be entered and the test started again Gas for the test jet shutter assembly is supplied from an integral gas tank which is filled using a standard butane lighter refill cartridge The instrument is lightweight and suitable for mobile use when operated from the optional 12 volt power supply adaptor SUPPLIED WITH 2ml syringe ignitor mains lead and instruction manual Note For close to ambient tests the sample cup requires cooling with 13870 0 Seta Coolant Module FOR SPECIFICATIONS ACCESSORIES amp CONSUMABLES SEE PAGE 14 SETAFLASH SERIES 3 CLOSED CUP TESTER ASTM D3278 D3828 E502 IP 303 obs IP 523 IP 524 ISO DIN 3679 ISO 3680 BS EN 456 BS 3900 Part A13 BS 6664 Parts 3 amp 4 CHIPS Regulations EPA 1020 A amp B UN Class 3 Non viscous Flammable Liquids Classification of Dangerous Goods for Carriage Viscous and Non Viscous Liquids Flash point test in less than 2 minutes Small sample size 2 or 4ml Ambient to 300 C temperature range Cost effective Portable operation Simple calibration The original Setaflash Series 3 tester Basically a 33000 0 without the temperature ramp mode the 30000 0 is a simple to use reliable and cost effective instrument that is to be found in laboratories refineries storage and transport facilities world wide SUPPLIED WITH 2ml syringe mains lead and instruction manual SETAFLASH SMALL SCALE FLASH POINT BIO FUEL TESTING C
408. te amp Clock for Data Record Keeping 99708 0 ACCESSORIES Conductivity Meter OPTIONAL 99708 002 BENCH STAND 99708 005 CARRY CASE The unit is provided in an industry standard polyamide housing with built in Lithium lon rechargeable battery system The conductivity sensor is constructed of two 316SS coaxial electrode sensors It has an easy to use menu system allowing up to 10 samples to be internally stored along with Sample Temperature Date and Time SPECIFICATIONS 2 pS m 2 of reading Power o 128x64 Dot Matrix Display Indicating Conductivity and Temperature EE Sample Trend Line Graph to Assist Data Collection Housing Polyamide BEEN ee AUTOMNTIC TESTERS 99600 2 99610 2 99620 2 99625 0 AUTOMATIC OIL TESTER 60KV AUTOMATIC OIL TESTER 80KV AUTOMATIC OIL TESTER 100KV ASTM D877 D1816 D3300 IP 295 AS 1767 BS 148 BS 5874 CEI 344 791 5702 IEC 156 NFC 27 NF 27 221 rOCT5861 SABS 555 VDE 0370 Automatic test sequence Pre set and user defined programs 60kV 80kV or 100kV models Integral printer RS232 interface Fully interlocked Multi language 99600 2 These oil test sets use either pre programmed or user defined parameters entered via the menu driven multi language display Results are printed out on an integral printer Features include a self check facility RS232C interface and safety interlock SUPPLIED WITH 36mm diameter
409. than 3 minutes per test The test kit is intended for use in the field by nontechnical people for the quantitative measurement of lead in unleaded gasoline in the range from 0 01 to 0 10g Pb U S gal 2 64 ro 26 4mg Pb L This method applies to all commercial gasolines and responds to all types of lead alkyls as well as to other organic and inorganic forms of lead SUPPLIED WITH UV Light and timer colorimeter filter and all necessary reagents glassware and consumbles Composition 86000 3 CONSUMABLES Portable Oil Condition Test Kit 86000 301 WATER IN OIL REAGENT pack A 8 B 50 tests 86000 302 TBN REAGENT pack C 50 tests 86000 303 SALT TEST KIT pack H 25 tests 86000 020 SPOT TEST PAPER pack of 50 86200 0 BIO FUEL TESTING Water 100 3000 ppm Density 850 950 kg m Viscosity 1 10 cSt 40 C Total Acid Number 0 6 TAN CONSUMABLES Biodiesel Test Kit 86200 001 WATER IN OIL REAGENT pack of 50 86200 002 TAN REAGENT CONSUMABLES Lead in Gasoline Test Kit 86300 001 REAGENT PACK A B amp C www stanhope seta co uk Composition Particulates Residues amp Composition SULPHUR LAMP METHOD 20410 0 SETA SULFUR LAMP METHOD UNIT ASTM D1266 D1072 D2384 D2784 IP 107 BS 2000 Part 107 DIN 51 400 NF M07 031 791 5201 For sulfur concentrations gt 0 002 20ppm Supports 5 sets of glassware Seta 20490 0 Integral manifolds with valves An apparatus for determ
410. timed periods up to 999 hours The oven can be controlled from the front panel and integral timer or by an IBM compatible personal computer not supplied connected to the RS232 port and using the supplied control data logging software An internal fan ensures even temperature distribution throughout the oven The internal working space is manufactured from corrosion resisting steel and has two moveable perforated stainless steel shelves SUPPLIED WITH 2 shelves software and instruction manual DESSICATOR e 200 ml and Disc SETA HOT e 1000W Hot Plate A general purpose laboratory electric hotplate Comprises a 1000W heater element mounted in a stainless steel case with a 70mm diameter plate set into a heat resistant top plate An integral energy regulator and rotary control allow fine temperature adjustment SUPPLIED WITH mains lead and instructions SETA STEAM GENERATOR 14kPa 2psi maximum steam pressure 525litres useable capacity Compact lightweight unit An electrically heated portable steam generator with a capacity of 7 12 litres 5 25 litres useable with the output regulated to a maximum of 14kPa 2psi The die cast aluminium water tank is fitted with a water level sight tube and is protected by a pressure relief valve The tank is tested to 140kPa 20psi Over temperature protection is via a resettable cutout that operates at a nominal 132 C and a thermal fuse that breaks at 184 C SU
411. tion Tester 00100 0 SUPPLIED WITH 1 transmitter module x ACCESSORIES Setalert receiver and recharging unit OPTIONAL N 00100 001 SETALERT TRANSMITTER additional transmitter module maximum 6 transmitters per receiver module Glassware General Laboratory Equipment STANDARD GLASSWARE If the method of test requires laboratory glassware items to be used in STANDARD GLASSWARE conjunction with an instrument in this catalogue the glassware is listed D86 Distillation in the relevant accessory box for the instrument Dean amp Stark for details see page 28 The table to the right lists some of the more common methods of test and A for details see page 64 instruments that use laboratory glassware and the section in which they O are listed DIN 51 587 for details see page 74 Quartz Tube Sulpur Apparatus Particulates Residues amp Composition Suplhur Lamp Apparatus for details see page 80 SPECIALISED GLASSWARE SETA can offer the following specialised glassware and apparatus If the glassware required is not listed please contact Stanhope Seta for a quotation SPECIALISED GLASSWARE Method Subject ASTM D70 D1481 D2111 Specific Gravity and Density of Liquid and Solid Petroleum Products IP 189 190 DIN 51 757 52 004 ASTM D1018 Hydrogen in Petroleum Fractions ASTM D2420 Hydrogen in Sulphide LP Gases by Lead Acetate Method ASTM D2569 Distillation of Pitch ASTM D3242 Acidity in
412. to 100 C Stability 0 1 C 1100W cooling power at 20 C Digital control Removeable top plate A low temperature bath with digital control providing a convenient refrigerated liquid source for cooling test apparatus or for direct immersion of samples Consists of a refrigerated 12 litre stainless steel bath with integral thermostatic temperature controller and a digitally controlled thermostir pump unit giving enhanced control and stability at temperatures between 47 and 100 C The unit can dissipate 1100W at 20 C Fitted with a removeable top plate and a socket for connection of a PT100 temperature probe SUPPLIED WITH mains lead and instruction manual Note Supplied excluding fittings I PP Om A h CDE F ICATIO NG Xi L U VAI v N J MINI LOW TEMPERATURE BATH CIRCULATOR Temperature range 20 to 100 C Stability 0 1 C 250W cooling power at 20 C Digital control Removeable top plate A small footprint low temperature bath suitable for providing a flow of chilled water for cooling applications or for direct immersion of samples Comprises a 5 litre refrigerated stainless steel bath with thermostatic control and a digitally controlled thermostir pump unit The unit can cool to 20 C and will dissipate 250W at 20 C Safety features include over temperature and anti fre
413. to extract and collect hot sample from cup MER SEE BE for details see page 15 30005 0 ADAPTOR FOR 12V POWER SUPPLY 12Vdeto230Vae e 30000 CARRYCASE gt 9 CALIBRATION VERIFICATION amp TRAINING 13751 0 THERMOMETER 0 to 110 C 13775 0 THERMOMETER 100 to 300 C 99878 3 SMALL SCALE CERTIFIED FLASH POINT MATERIAL for details see page 15 99928 0 SETATHERM digital thermometer 20 to 150 C for details see page 129 CONSUMABLES Setaflash Series 3 2 Years 2000 Tests Qty 33250 2 Oty 33200 2 33000 0 Qty 30000 0 SIUCONERUBBER TUBE Amet 1310404 SAMPLEWELL O RING SSS 1371000 SAMHEWELU RNGSime LIS DIT I m a 14 44 0 1932 564391 F 44 0 1932 568363 LE sales stanhope seta co uk w www stanhope seta co uk Small Scale Flash Point Flash Point Smoke Point amp Sustained Burning SETAFLASH SMALL SCALE FLASH POINT 99878 3 SMALL SCALE CERTIFIED FLASH POINT MATERIAL ASTM 03278 D3828 07236 IP 523 Yr IP 524 IP 534 BS 3900 Part A13 ISO 3679 CERTIFICATE OF MEASUREMENT WORKS ISO 3680 UN Class 3 Non viscous Flammable Liquids Small Scale Certified Flash Point Material is suitable for Closed Cup test methods and is produced in accordance with ISO Guides 34 and 35 for closed cup test methods Nominal certified flash point value 74 uncertainty 0 3 C Supplied i
414. truction manual CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE SPECIFICATIONS Operating temperature range 140 to 260 C 5 C 2x 1kW 280 C adjustable Heaters Over temperature cut out Air Steam inlet 15mm o d pipe Calibrated for min and max air and steam flow Power 2kW Flow indicator Voltage 110 120V 50 60Hz 220 240V 50 60Hz Size HxWxD 45 x 35 x 50cm Weight 45kg 12200 3 ACCESSORIES Existent Gum Solid Block Bath REQUIRED 12311 2 INSTALLATION KIT connects bath to steam generator and comprises all tubes valves filters and regulators needed for a typical installation 12312 0 BEAKER EXTRACTION TOOL for removal of beakers from solid block bath THERMOMETERS ASTMSC IP73C or ASTMSF IP73F Note Other items which may be required include Cooling Vessel Glass Filtering Funnel Special detergent or chromic acid Solvents OPTIONAL 12310 3 STEAM GENERATOR electrically heated with water feed pump safety valve preset at 1 bar water level control and cut out Produces 18kg hr 40lb hr of steam at 100 C Maximum working pressure 10 bar 150Ibf in2 Voltage 380 415V 50 60Hz 3 phase Power 12kW Size HxWxD 64 x 61x 91cm Weight 111kg ROTARY COMPRESSOR Voltage 240V 50Hz Power 2 2kW Size HxWxD 47 x 27 x 70cm Weight 41kg Output 0 24 m per min
415. tured Ethyl Alcohol Denatured Ethyl Alcohol d es R404A CFC HCFC free 220 240V 50 60Hz 110 120V 60Hz 220 240V 50Hz 780W 3 1kW 55 x 49 x 53cm 66 x 56 x 55cm 52kg 130kg Tube Capacity Bath Fluid Bath Capacity Refrigerant Voltage Kinematic Capillary Viscosity LOW TEMPERATURE KINEMATIC VISCOMETER BATHS ACCESSORIES Low Temperature Viscosity Baths REQUIRED KINEMATIC VISCOMETER TUBES Refer to pages 42 to 44 94701 0 VISCOMETER TUBE HOLDER for Cannon Fenske tubes 94702 0 VISCOMETER TUBE HOLDER for Ubbelohde tubes 94703 0 VISCOMETER TUBE HOLDER for U Tube Reverse Flow tubes Holders for other types of tube available THERMOMETERS ASTM72C IP67C or ASTM73C IP68C or ASTM74C IP69C or ASTM126C IP71C or ASTM127C IP99C or ASTM128C IP33C OPTIONAL 83750 3 SETATIME SIX CHANNEL QUARTZ TIMER for time measurement to 999 99 seconds accuracy 99 999 1 digit at 20 C for details see page 141 SPIRIT LEVEL BENCH VISCOMETER STAND framework holds viscometer tubes near vertical while being prepared or while draining after use complete with drainage tray 97100 0 VISCOMETER TUBE CLEANER for details see page 39 CALIBRATION VERIFICATION amp TRAINING LOW TEMPERATURE VISCOSITY STANDARDS for details see page 48 CONSUMABLES Low Temperature Viscosity Baths 2 Years 2000 Tests 94700 2 Only 94700 201 SPARES KIT 84005 0 84008 0 VISCOMETER TUBE CLEANER TUBE CLEANER 97100
416. ual Notes Supplied without viscometer tubes or thermometers refer to the accessories section BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS DOD SETAPLUS EXTENDED WARRANTY AVAILABLE L TECHNICAL DATASHEETS AVAILABLE SETAVIS KINEMATIC VISCOMETER ASTM D7279 Houillon Method Correlates with ASTM D445 D446 D2270 IP 71 IP 226 BS 188 BS 2000 Part 71 BS 4459 EN 3104 ISO 2909 ISO 3104 FTM 791 305 NF T60 100 NF T60 136 JIS K2283 Temperature range 0 to 150 C Up to 6 viscometer tubes Integral 6 channel digital timer In situ tube cleaning with integral vacuum pump The 83541 3 is a compact version of the 83542 0 kinematic viscometer with one temperature controlled bath providing capacity for six Setavis viscometer tubes and six simultaneous measurements Complete with integral 6 channel timer and vacuum pump for in situ cleaning SUPPLIED WITH mains lead and instruction manual BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS SETAPLUS EXTENDED WARRANTY AVAILABLE TECHNICAL DATASHEETS AVAILABLE DOOD 83542 0 Viscometer tubes supplied separately 83541 3 Viscometer tubes supplied separately ACCESSORIES Setavis Kinematic Viscometer 83600 0 SETA KINEMATIC VISCOMETER TUBES set of nine range 3 to 2000mm s Calibration based on a minimum flow time of 200 seconds at 40 C CALIBRATION CERTIFICATE WORKS Note If a full set is no
417. ulding Main PCB Top Moulding Tube Fitting Assembly Printer Paper pack of 20 Syringe 5m amp needles Syringe 5ml c w LeurLock Needle for 81003 001 pack of 2 Setaflash Series 8 Closed Cup Tester 11 Flash Detector Ignitor Keypad Keypad Gasket Servo Display PCB Display Display Ribbon Cable Peltier PCB Ignitor PCB Main PCB Fuse 5A pack of 5 Heater Thermofoil Lid amp Shutter Programming Plug Battery Cell pack of 2 0 Ring Setaflash Series 8 Activecool CC Tester 10 Flash Detector Ignitor Keypad Keypad Gasket Servo Display PCB Display Display Ribbon Cable Peltier PCB Ignitor PCB Main PCB Fuse 5A pack of 5 Lid amp Shutter Programming Plug Battery Cell pack of 2 0 Ring Setaflash Series 8 Activecool Corr Res 10 Index Part Number 82000 001 82000 002 82000 003 82000 004 82000 005 82000 006 82000 007 82000 008 82000 009 82000 010 82000 011 82000 012 82000 014 82000 015 82000 016 82000 018 83201 2 11200 021 15140 005 15152 201 22600 002 22600 003 22600 008 23000 002 50000 001 50000 002 50000 004 50000 005 83260 001 83340 001 83541 3 83542 0 13740 008 17400 007 22420 005 50000 005 83540 001 83540 003 83540 008 83540 009 83540 012 83540 019 83540 021 83540 202 83541 301 8354 1 302 83541 303 83541 304 83541 305 8354 1 306 83550 3 83750 301 83750 303 83750 308 83545 3 13740 008 13740 017 17400 007 22420 005 50000 00
418. upply exceeds 18 C for details see page 139 SETAPLUS EXTENDED 12 MONTH WARRANTY VISCOSITY STANDARDS for details see page 48 99928 0 SETATHERM precision logging digital thermometer optimised for verification of viscosity baths for details see page 129 Note Other items which may be required include Solvents for tube cleaning CONSUMABLES Setavis Kinematic Viscometer 22420 005 O RING PIPE SEAL 10 2 83541 302 TUBE DUST COVER pack 0 24 12 emas 1 SPECIFICATIONS Seat Part No 83542 0 83541 3 Viscosity Range 2 5 to 2000 mm s 2 5 to 2000 mm s Temperature Range Ambient to 150 C Ambient to 150 C Temperature Stability 30 01 below 100 C 0 01 below 100 C a 0 03 100 to 150 C 0 03 100 to 150 C Sample Size 0 15 to 0 275 ml Typical Flow Time 0 15 to 0 275 ml 50 to 100 seconds 50 to 100 seconds No of Timer Channels 6 6 No of Baths 2 1 Bath Capacity 2 litres 2 litres Tube Capacity to 12 6 per bath up to 6 Voltage 110 120V 50 60Hz 110 120V 50 60Hz 220 240V 50 60Hz 220 240V 50 60Hz switchable switchable Power 800W 450W Size HxWxD 68x 59 x 30cm 80x 40 x 30cm Weight 22kg 44 0 1932 364391 LF 44 0 1932 368363
419. us and Non viscous Liquids EPA 1020 A amp B 34000 0 UNIVERSAL BASE UNIT Multi Method Flash Point Flash Point Smoke Point amp Sustained Burning MODULAR FLASH POINT TESTER ALL MAJOR TEST METHODS Pensky Martens A B amp C Closed Cup and Chinese Method GB Abel Closed Cup amp Equilibrium TAG Closed Cup amp Equilibrium Cleveland Open Cup Small Scale Rapid Equilibrium Setaflash UNIVERSAL OPERATION Unique 5 in 1 modular solution for flash point testing All primary flash point tests from one instrument Universal base interchangeable test modules Gas or electric ignition FULLY AUTOMATIC Automatic set up of test parameters Automatic heating control ignition amp flash detection Automatic test results amp end of test warning Automatic barometric correction UNRIVALLED EASE OF USE Minimum operator input Integral self diagnosis e LOW COST Modular design optimises capital outlay Instrument can be configured to match the requirements of the user Simple to extend range of test methods by adding modules e STRICT CONFORMITY TO TEST METHODS Precise results Procedures in conformance with method of test Critical components designed in exact conformance with test methods Easy and quick calibration and verification procedures FAST amp RELIABLE PERFORMANCE Designed for long service life Reliable and proven technology Simple operation Error messaging Calibration amp diagnostics mode
420. valve quick release coupling neoprene tube and instruction manual Note Supplied without mercury CALIBRATION CERTIFICATE WORKS 22470 3 SETA MANOMETER Verification of pressure gauge up to 135kPa 19 5psi 0 5kPa graduations Mercury type unbreakable plastic construction wall mounting Note Supplied without mercury CALIBRATION CERTIFICATE WORKS 80005 2 SETA PRESSURE CALIBRATOR For verification above 180kPa 26psi Accuracy 0 01596 indicated pressure 22430 3 A deadweight tester with integral handpump and pressure gauge SUPPLIED WITH set of calibrated weights Note Refer to Section 22 CALIBRATION for more details CALIBRATION CERTIFICATE UKAS Vapour Pressure Wet Method VAPOUR PRESSURE CYLINDERS PRESSURE CYLINDERS ASTM D1267 IP 161 obs IP 410 BS 2000 Part 410 EN ISO 4256 NF M41 010 22300 2 22310 2 22320 2 Pressure Tested amp UKAS Certified to 6900kPa 1000psi Stainless steel construction SETA MAIN CHAMBER e Ullage to cylinder ball valve 22560 0 Fine control bleeder valve SETA 20 ULLAGE CHAMBER Fine control ullage inlet valve SETA 337 ULLAGE CHAMBER 220 2 Fine control inlet valve 22310 2 Used to determine the vapour pressure of LPG to avoid exceeding pressure safety limits during storage handling and use Vi PRESSURE CERTIFICATE UKAS ACCESSORIES Vapour Pressur
421. valves In operation the cooling unit is filled with solid carbon dioxide and the inlet is connected to the sampling point The sample is drawn into the cooling unit and is isolated by closing the valves Liquefied gas is then drawn from the bottom of the cooling unit via the outlet tube which may be connected to a pressure sampling or vapour pressure cylinder CDEPICIFATINNG SPECIFICATIONS Size HxWxD Weight 33 x 85 x 26cm 2 9kg ACCESSORIES LPG Corrosion Pressure Vessel REQUIRED 11241 0 SILICONE CARBIDE PAPER 105 150 grit 28 x 23cm pack of 50 11460 0 SILICONE CARBIDE CLOTH 65um 240 grit 28 x 23cm pack of 50 11470 0 SILICONE CARBIDE PAPER 100 grit 28 x 23cm pack of 50 11480 0 SILICONE CARBIDE GRAINS 105um 150 mesh pack of 5 x 300g 11530 0 SETA MULTI STRIP VICE to hold copper strips while being polished 11570 0 FLAT GLASS TEST TUBE to protect strip during inspection pack of 10 11580 0 COPPER STRIP CORROSION STANDARD a set of thirteen plaques printed on aluminium and encased in plastic for protection 22190 0 COPPER TEST STRIP 75 x 12 5 x 2 4mm with 3 0mm hole pack of 30 supplied with material certificate 22220 4 CORROSION BATH see separate entry for details 22230 0 SETA BRACKET holds Pressure Vessel correctly in bath pack of 3 THERMOMETERS AS
422. ware disc and user manual Other accessories Size HxWxD 17 25 with probe x 8 6 x 3 4cm including sample holder and multiple sample storage unit are available Composition Particulates Residues amp Composition Advanced Chromatogpraphy Package SeraAnalultics cevochram HPLC SYSTEMS Complete HPLC Pack system allows plug and go for the busy lab Precision engineered HPLC hardware with proven technology Quality separations provide accurate and precise results every time Each Diesel System includes Sample Injector HPLC Isocratic Pump Optional Solvent Reservoir Degasser Unit Column Oven with Safety Solvent Alarm System Amino Column as specified in Test Method Refractive Index Detector ChromGate Integration Software Package SA2000 0 c c chram SDA SYSTEM ASTM D7524 IP 568 Measures Static Dissipator Additive SDA in Jet and Diesel fuels Chromatography assured with optimised column technology meeting the latest IP 568 and ASTM 7524 requirements Ideal for QC checking in distribution systems SA2200 0 c chrarm DIESEL SYSTEM ASTM D6591 IP 391 EN 12916 BIO FUEL TESTING Measures Aromatics in Diesel and Bio Diesel Chromatography assured with optimised column technology meeting the latest ASTM D6591 IP 391 and EN 12916 Method OPTIONAL SOFTWARE AVAILABLE Ee requirements TECHNICAL DATASHEETS AVAILABLE Fully compatible to meet and measure to
423. ween sample source and charging lead or charging lead and sampling cylinder One end fitted with 1 8in BSP female the other 1 8in BSP male Set to relieve at 14 bar 200psi A double valve cylinder with high pressure charging 21790 0 SETA QUICK CONNECTION COUPLING HIGH PRESSURE male Hansen to 1 8in BSP male components for pressures up to 46 bar 670psi 21800 0 SETA QUICK CONNECTION COUPLING HIGH PRESSURE female Hansen to 1 8in BSP male for pressures up to 46 bar 670psi 21810 0 SETA QUICK CONNECTION COUPLING LOW PRESSURE male Schrader to 1 8in BSP male for pressures up to 14 bar 200psi 21790 0 21810 0 15620 2 21820 0 21820 0 SETA QUICK CONNECTION COUPLING LOW PRESSURE female Schrader to 1 8in BSP male for pressures up to 14 bar 200psi 21830 0 SETA ADAPTOR 1 8in BSP male suitable to convert sampling cylinder valve from female to male pack of 2 ah o 21832 0 SETA ADAPTOR 1 4in BSP male to 1 8in BSP female suitable for use wih 22100 0 Pressure Hydrometer Apparatus pack of 2 21835 0 SETA ADAPTOR 1 4in BSP female to 1 8in BSP female suitable for use with 22150 3 LPG Corrosion Test Vessel pack of 2 21840 0 SETA CONNECTOR PIPE copper 1 4in diameter x 20 SWG One metre long plain end of 1 8in BSP male 21850 0 SETA CONNECTOR PIPE copper 1 4in diameter x 20 SWG One metre long plain end to 1 8in NPTF male 21501 3 SETA PROTECTION COLLAR prevents damage to valves stops rolling use as a
424. with fuels containing flow improving additives Comprises a 4 litre dry ice bath Dewar Flask and a CFPP test insert connected via a three way cock to a U tube manometer and two 5 litre pressure equalising vessels SUPPLIED WITH interconnecting tubing ACCESSORIES Apparatus _ REQUIRED THERMOMETERS ASTMBC IP1C or ASTM5F IP1F or ASTMGC IP2C or ASTM6F IP2F Note Two thermometers are required for IP 309 14030 2 AIR PUMP for details see page 136 70220 3 PORTABLE DRY ICE MAKER MODEL B produces one 1kg 2 216 block in approximately 1 minute for details see page 53 99000 2 Stand not included BIO FUEL TESTING CALIBRATION amp VERIFICATION MATERIALS S CALIBRATIO N VERIFICATION amp TRAINING 99851 0 MULTI TEST VERIFICATION MATERIAL ASTM 06371 IP 309 Gas Oil EN 116 for details see page 150 99908 0 BIO FUEL MULTI TEST VERIFICATION MATERIAL for details see page 151 3 CDLPICICLATINNG r Im Li l vi LU IUvuniilyiYJ 6kg 94000 2 COLD FILTER PLUGGING POINT CFPP BATH ASTM D6371 IP 309 BS 2000 Part 309 BS 6188 EN 116 NF 116 Digital temperature control Accepts tubes Consists of a stainless steel bath with integral thermostatic temperature controller and circulator for enhanced control and stability at sub ambient temperatures An internal removable rack can accommodate 3 col
425. ww seta consumables co uk Specialist laboratory website for consumables for Petroleum testing Stanhope Seta offer delivery from stock on a wide range of consumables in conformity with ASTM IP DIN and other petroleum test methods Glassware Reference materials Catalysts amp others Volume discounts and standing order opportunities Contact us for more information about volume discounts and standing order opportunities to ease and improve your consumables purchasing requirements WWW SeETS CONSUMBaDIES CO UK ikse is in refinery E quotes stanhope seta co uk T 44 0 1932 5643291 w www seta consumables co uk Foaming Air Release amp Emulsification Foaming FOAM TEST BATHS TEST BATHS 14020 5 SETAFOAM DUAL TWIN FOAM TEST BATHS ASTM D892 IP 146 BS 2000 Part 146 ISO 6247 NF T60 129 FTM 791 3211 JIS K2518 High and low temperature baths Temperature range ambient to 100 C Up to two simultaneous tests per bath Two pre heating stations per bath Integral flowmeters and regulators Two integral normalising coils A pair of highly transparent water baths for detecting foaming characteristics in lubricating oils which could cause inadequate lubrication overflow and cavitation The instrument comprises a high temperature 93 5 C and a low temperature 24 C bath each with the capacity to hold four 1000ml graduated glass cylinders Each bath assembly comprises
426. x3 2cm 0 5kg Resolution Power Supply Seta Part No Range 99920 0 30 to 50 C 99925 0 90 to 110 C SPECIFICATIONS Resolution 9V 6F22 PP3 Alkaline Battery 12x 6 x2 5cm Power Supply CALIBRATION CERTIFICATE WORKS S 99928 0 Vi CALIBRATION CERTIFICATE WORKS SOFTWARE INCLUDED TECHNICAL DATASHEETS AVAILABLE OOG Temperature amp Fluid Density PRECISION DIGITAL THERMOMETER 99925 0 RECORDING DIGITAL THERMOMETER Temperature amp Fluid Density Digital Thermometers WIDE RANGE DIGITAL THERMOMETERS 99922 0 SETA DIGITAL THERMOMETER 40to 150 C temperature range 3second response time Calibrated for Vapour Pressure tests verification A digital thermometer with a temperature range of 40 to 150 C a rapid response time of only 3 seconds and optimised for temperature measurement in vapour pressure tests The thermometer is equipped with a 110 x 2 5mm stainless steel probe that has the element in the last 10mm of the tip and has been calibrated at 37 8 C 100 F making it ideal for the calibration and verification of Setavap instruments SUPPLIED WITH probe with 1 2m cable battery and user instructions CALIBRATION CERTIFICATE WORKS WE SPECIFICATIONS 0 1 37 8 C 100 F Power Supply 9V 6F22 PP3 Alkaline Battery 0 5kg 99927 0 DIGITAL THERMOMETER WITH INTERCHANGEABLE PROBES 50 to 300 C range Im
427. y provide additional details All documents are in Pounds Sterling unless stated to the contrary Invoices submitted on the basis of an Approved Credit Account are due for payment within 30 days of invoice date The right is reserved to charge interest on overdue accounts at a rate equivalent to 496 above the applicable statutory default interest rate 1 Warranty We warrant that SETA equipment will be free from defects of workmanship design or materials for a period of 18 months from the date of leaving our factory SetaPlus Extended Warrantiy is available for many SETA instruments please refer to our catalogue or website for details During the warranty period we have the options either to repair or to replace faulty equipment Please refer to us before returning goods in query under warranty giving full details Whilst every possible effort will be made to give complete satisfaction our decision is final Not withstanding the above warranty Stanhope Seta will have no liability to repair or replace goods or to compensate the customer i as a result of defects arising from fair wear and tear including bearings seals switches and any other components which due to their nature have moving parts that under certain operating conditions may have an effective working life of less than the standard warranty period ii if the equipment is not used in accordance with the design specifications and the installation and operating
Download Pdf Manuals
Related Search
Related Contents
HP X1200 ASUS ROG GL552JX-DM109D notebook HE500TSW232 Manual - Platforma Internetowa ASTOR. もくじ ポータブルトイレ FX-CP〈ちびくまくん〉 快適脱臭取扱説明書 取付・取扱説明書PDF Jøtul F 500 Cables Direct 2VV-01 User Manual - Cnchelicopter.com MANUAL Di700_SP PER/183/1205 Copyright © All rights reserved.
Failed to retrieve file