UL TEST REPORT AND PROCEDURE - TDK

image

Contents

1. 3 3 5 5 16A 5 5 5 5 8A 5 5 5 5 12 5A 12 12 15 5 10A 15 12 15 5 10A 12 12 15 5A 15 12 15 5A 12 12 15 8A 15 12 15 8A 24 18 24 5 2 5A 3 3 Fixed 2A 5 Fixed 2A 12 Fixed 1A 15 Fixed 1A 12 Fixed 2A 15 Fixed 2A 5 ATX Fixed 2A 12 ATX Fixed 1A 13 5 ATX Fixed 1A Channels 1 and 2 combined output currents must not exceed 40A Channel 1 with G output 25V max with 5V channel 2 fitted Max Power W 200 300 300 13 5 Issue Date 2012 10 04 Page 4 of 16 Report Reference E135494 A86 UL Additional variations and limitations of use for fan version with 5V channel 1 Output power de rated 3W per volt from 100Vac to 90Vac at 90Vac input 270W output Unit with global option high current channel 2 de rated to 21A Unit without global option high current channel 2 de rated to 19A Unit without global option low current channel 2 de rated to 13A Additional variations and limitations of use for all fan version Channel 4 3H 5H TH and FH max output current 1 5A The products listed in the following table are typical examples Model CH1 CH2 CH3 CH4 Global Option NVA3 453FFH 5V 40A 3 3V 15A 15V 5A 15V 2A_ NV3A 453HFHFH N3 5V 40A 3 3V 24A 15V 8A 15V 2A 5V 2A NV3A 4GFGT N5 24V 12 5A15V 10A 24V 2 5A 12V 1A 13 5V 1A Output Limitations All outputs are SELV All outputs have functional spacings to earth and due consideration must be given to this in the end product design Adjusting output volta
2. H FH OH fan only channel 4 output followed by P for positive output or 0 f Global Option N3 for 5V version with ATX compatibility N4 for 12V version with ATX N5 for 13 5V version ATX compatibility or nothing for no Global Option present g U for U chassis C for U chassis and cover F for U chassis and cover with fan for U chassis and cover with fan and IEC inlet or nothing for Open Frame ijk Three numbers from 0 to 9 which denotes various output voltages and currents within the specified ranges of each output for a particular unit or blank for standard output settings a b c d e Issue Date 2012 10 04 Output Voltage Cross Reference Designation 0 ONANAN Output Voltage Omit output 1 5 1 8 2 2 7 3 3 5 7 12 15 24 Page 3 of 16 Report Reference E135494 A86 UL All channels are adjustable except for Channel 4 and Global Options in accordance with the following table O P Channel CH1 CH2 CH1 5V CH2 CH1 12V CH2 CH1 24V CH3 CH4 CH4 fan output Global Option Designation 5 N 0H 2H ao o o N3 N4 N5 Variations and limitations of use Maximum 300W power output With 180Vac and greater input voltage output power 300W plus global option max 313 5W Vout V Range V out A 5 5 5 5 40A 12 12 13 2 25A 24 24 28 5 12 5A 1 8 0 9 2 5 15A 2 7 2 5 3 8 15A 2 7 2 5 3 8 24A 3 3 2 5 3 8 15A 3 3 2 5 3 8 24A 5 3 3 5 5 10A 5
3. Issue Date 2012 10 04 Page 1 of 16 Report Reference E135494 A86 UL UL TEST REPORT AND PROCEDURE Standard UL 60950 1 2nd Edition 2011 12 19 Information Technology Equipment Safety Part 1 General Requirements CSA C22 2 No 60950 1 07 2nd Edition 2011 12 Information Technology Equipment Safety Part 1 General Requirements Certification Type Component Recognition CCN QQGQ2 QQGQ8 Power Supplies for Information Technology Equipment Including Electrical Business Equipment Product Switch Mode Power Supply Model NV300 or NV 300 Series NVx abcde f g ijk See model differences for details of models and nomenclature Rating 100 240Vac nom 5Arms max 45 440Hz 133 318Vdc nom 3 8Adc See model differences for details of ratings Applicant Name and Address TDK LAMBDA UK LTD KINGSLEY AVE ILFRACOMBE DEVON EX34 8ES UNITED KINGDOM This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow Up Service under the indicated Test Procedure The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC UL in accordance with the Follow Up Service Agreement Only those products whic
4. d Edition A1 Some test results have been accepted based on the CB Test Report previously issued by BSI CB Test Report Ref No 249 4887224 and addendum 249 7112461 CB Test Certificate Ref No GB744W M1 attached as test reference Additional Standards The product fulfills the requirements of EN 60950 1 2006 A11 2009 A12 2011 CSA C22 2 No 60950 1 07 A1 2011 Markings and instructions Clause Title Marking or Instruction Details Power rating Model Model Number Issue Date 2012 10 04 Page 7 of 16 Report Reference E135494 A86 UL Power rating Ratings voltage frequency dc current Ratings Power rating Listee s or Recognized company s name Trade Name Trademark or File Company identification Number Fuses Rating Rated current and voltage and type located on or adjacent to fuse or fuseholder Terminal for main protective earthing Provided adjacent to the main protective earthing terminal 60417 5019 Special Instructions to UL Representative N A Production Line Testing Requirements Electric Strength Test Special Constructions Refer to Generic Inspection Instructions Part AC for further information Removable V Test Time Model Component Parts Test probe location rms V dc s N A Earthing Continuity Test Exemptions This test is not required for the following models N A Electric Strength Test Exemptions This tes
5. d in the body of each Test Report Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products Products are permitted to bear only the Certification Mark s corresponding to the countries for which it is certified as indicated in each Test Report Product Description NV300 or NV 300 series Switch mode power supplies for building into end equipment Model Differences Input Parameters NOMINAL INPUT VOLTAGE RANGE 100 240V AC 133 318Vdc MAXIMUM INPUT VOLTAGE RANGE 90 264V AC 120 350Vdc INPUT FREQUENCY 45 440Hz MAXIMUM dc MAXIMUM INPUT CURRENT 5Aac rms 3 8Adc INRUSH CURRENT lt 15A AT 25 C For IEC EN60601 1 45 63Hz only All ratings apply for ambient temperatures up to 50 C From 50 to 65 C the total output power and the module current ratings are both derated at 2 5 per deg C Output Parameters NV300 or NV 300 models as described below Unit Configuration Code NVx abcde f g ijk may be prefixed by NS or where may be up to any four letters and may be followed by where may be any number between 000 to 999 indicating non safety related model differences where A3 for NV300 Number of Outputs 1 2 3 or 4 Channel 1 Output Voltaget 5 T or G Channel 2 Output Voltaget 1 2 2H 3 3H 5 5H T F or 0 Channel 3 Output Voltaget T F TH FH G or 0 Channel 4 Output Voltaget 3H 5H T F T
6. ge beyond the stated range may cause overvoltage protection OVP to operate To reset for normal operation simply adjust the potentiometer to reduce the output voltage to within its range or cycle the input off then on if the unit has latched off after adjusting the potentiometer Seriesing of outputs are not allowed Products may additionally be marked with NV3xxxxx or Y3xxxxx where x can be any letter or number between 0 and 9 indicating non safety related model differences Technical Considerations Equipment mobility for building in Connection to the mains Connection to the mains via host equipment Operating condition continuous Access location for building in Over voltage category OVC OVC II Mains supply tolerance or absolute mains supply values 10 10 AC 120 350Vdc absolute values Tested for IT power systems Yes Norway only T testing phase phase voltage V 230V Issue Date 2012 10 04 Page 5 of 16 Report Reference E135494 A86 UL Class of equipment Class earthed Considered current rating of protective device as part of the building installation A 20A Pollution degree PD PD 2 P protection class IP XO Altitude of operation m 3000m Altitude of test laboratory m 64m Mass of equipment kg 1kg maximum The product was submitted and evaluated for use at the maximum ambient temperature Tma permitted by the manufactu
7. h properly bear the UL Mark are considered as being covered by UL s Follow Up Service under the indicated Test Procedure The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability Any information and documentation involving UL Mark services are provided on behalf of UL LLC UL or any authorized licensee of UL Prepared by Pascal DANIEL Reviewed by Dennis Butcher Copyright 2012 Issue Date 2012 10 04 Page 2 of 16 Report Reference E135494 A86 UL Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report A Authorization The Authorization page may include additional Factory Identification Code markings B Generic Inspection Instructions i Part AC details important information which may be applicable to products covered by this Procedure Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report ii Part AE details any requirements which may be applicable to all products covered by this Procedure Products described in this Test Report must comply with any applicable items listed unless otherwise state
8. rer s specification of 50 C full load 65 output power decreasing linearly by 2 5 C above 50 C The product is intended for use on the following power systems DC mains supply TN IT for Norway only The equipment disconnect device is considered to be provided by the end equipment The product was investigated to the following additional standards EN 60950 1 2006 A11 2009 A1 2010 A12 2011 which includes all European national differences including those specified in this test report The following were investigated as part of the protective earthing bonding Printed wiring board trace refer to Enclosure Schematics PWB for layouts The following are available from the Applicant upon request Installation Safety Instructions Manual Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC When installed in an end product consideration must be given to the following The following Production Line tests are conducted for this product Electric Strength Earthing Continuity The end product Electric Strength Test is to be based upon a maximum working voltage of Primary SELV 422Vrms 676Vpk Primary Earthed Dead Metal 391Vrms 426Vpk Issue Date 2012 10 04 Page 6 of 16 Report Reference E135494 A86 UL The following secondary output circuits are SELV All The following secondary o
9. t is not required for the following models N A Electric Strength Test Component Exemptions The following solid state components may be disconnected from the remainder of the circuitry during the performance of this test N A Sample and Test Specifics for Follow Up Tests at UL Test Model Component Material Test Sample s Specifics
10. utput circuits are at hazardous energy levels CH1 and CH3 The following secondary output circuits are at non hazardous energy levels CH2 CH4 and option The power supply terminals and or connectors are Not investigated for field wiring The maximum investigated branch circuit rating is 20 A The investigated Pollution Degree is 2 Proper bonding to the end product main protective earthing termination is Required An investigation of the protective bonding terminals has Been conducted The following magnetic devices e g transformers or inductor are provided with an OBJY2 insulation system with the indicated rating greater than Class A 105 C TX2 TX4 TX701 class F all OBJY3 The following end product enclosures are required Mechanical Fire Electrical The following components require special consideration during end product Thermal Heating tests due to the indicated maximum temperature measurements during component level testing Models without a fan require component temperatures monitored as detailed in the handbook user manual cooling for units with customer air open frame U and C options Fans The fan provided in this sub assembly is provided with a fan guard to reduce the risk of operator contact with the stator The fan provided in this sub assembly is not intended for operator access Additional Information The product was investigated by UL for compliance with UL IEC 60950 1 2n