1. Event type Description A Alarm in event M Motion detection event L Video loss event 5 5 3 Email Notice The item enables ON disables OFF the Email notification of an event When an alarm event is triggered and lt Email Notice gt is enabled an e mail concerning the alarm event will be dispatched 5 5 4 Event Duration This item determines the duration of the buzzer and Alarm Out relay function after an alarm is triggered The available event duration range is from 1 second to 100 seconds The default is 5 seconds 5 5 5 Per Channel Configuration This item is used to set how alarm conditions are handled Select a desired channel and configure its settings such as Video Loss Detect Motion Detect and Alarm In Out functions Per Channel Config CH 1 Video Loss Detect Motion Detect Detection Config Alarm In Alarm Qut CH 2 CH 3 x CH 4 EH 5 CHE CH 7 CH 8 Video Loss Detect This item allows user to enable disable Video Loss as an alarm event Select ON to enable Video Loss alarm events OFF to disable Motion Detect Use to enable or disable the motion detection function of the DynaGuard 200 series By default the value is OFF www dynacolor com tw 147 All rights reserved DYNACOLOR Ke User s Manual If motion detection function is enabled it is required to define the motion detection parameters such as detection area and sensitivity settings Dete
2. 5 9 8 Erase Disc This function is used to remove information found on a CD RW or DVD RW disk prior to exporting new information to the drive Select lt YES gt and press ENTER to start deleting data 5 9 9 Begin Export Select lt YES gt and press ENTER to start exporting 5 10 Shutdown The item is used to shut down or reboot the unit If you must shut down the DynaGuard 200 series for any reason please use the proper shut down and power up procedures to avoid damage to your unit Select lt Shutdown gt in Main menu and press ENTER to access the Shutdown menu which displays as follows Shutdown 1 Power Off 2 Reboot Power Off Select this item to shut down the unit Do not remove the power during shut down until the message You can safely turn off DVR now displays Reboot Select this item to reboot the unit The color bar and system checking information are displayed on the monitor until the unit is completely restarted www dynacolor com tw 95 All rights reserved User s Manual DYNACOLOR Ke Appendix A Technical Specifications All specifications are subject to change without notice 96 Specifications Compact size Half rack mountable size Video Operation Triplex operation Operating system Embedded Compression algorithm MPEG 4 Video Input 4 8 Channels Vp p 75 ohm Main Monitor Output 1 BNC S video Vp p 75 ohm Call Monitor Output 1 BNC VGA Output Yes
3. e n User Permission menu select the users that will be using this connection If needed add a new user with the same user password that is set up in Dial out Setup menu in local DVR When done click Next to continue www dynacolor com tw 105 All rights reserved DYNACOLOR User s Manual r New Connection Wizard User Permissions You can specify the users who can connectto this computer Selectthe check box nextto each user who should be allowed a connection to this computer Note that other factors such as a disabled user account may affect a user s ability to connect Users allowed to connect o vmware user vmware user Ivi 1234 1234 R I admin admin 1234 DL Ke Andy Wu D Ke ASPNET ASP NET Machine Account R D I Guest M Je Lal Add Remove Properied lt Back Next gt Cancel e In Networking Software menu select lt TCP IP gt and click on lt Properties gt S 4 New Connection Wizard Networking Software Networking software allows this computer to accept connections from other kinds of computers Selectthe check box nextto each type of networking software that should be enabled for incoming connections Networking software MF Internet Protocol TCP IP a M A File and Printer Sharing for Microsoft Networks C amp VMware Bridge Protocol v Ls Description Transmission Control Protocol Int
4. AN NOTE If selecting the Record mode lt 720x480 30PPS gt 720x 576 25PPS only the image from channel 1 4 will be recorded AN NOTE After changing the Record Mode setting the warning message This will FORMAT ALL HARDDISKS and LOAD THE FACTORY DEFAULT CONFIG will show Press ENTER to confirm the selection then the unit starts to format the hard disks and load the factory default settings or press ESC to abort Schedule Setup This submenu is used to set the day and night time or weekend recording schedule The Night and Day schedules are used to define daytime and nighttime the Weekend schedule is tailored for weekends and holidays Select lt Schedule Setup gt from the Record Setup menu and press ENTER www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual the following menu is displayed Schedule Setup 1 Day Time Start 06 00 2 Night Time Start 18 00 3 Weekend Schedule YES 4 Weekend Start Fri 18 00 5 Weekend End Mon 06 00 5 4 2 1 Day Night Time Start The Day Night Start Time determines the beginning of day night recording time Time is indicated in 1 minute increments The time display format in this menu is based on the setting of Time Display Mode 5 4 2 2 Weekend Schedule The Weekend Schedule determines whether a weekend schedule is in effect Choose YES to take effect the related weekend settings 5 4 2 3 Weekend Start End The Weekend Start Time
5. W indicates wintertime Search by Event Follow the steps to search video by event e Press SEARCH button to enter the Search menu e To search event video that was recorded on a specific camera use LEFT RIGHT to move the cursor and press ENTER to select or de select a channel www dynacolor com tw 39 All rights reserved DYNACOLOR Ke User s Manual e Move the cursor to Event List and press ENTER to list the event video of the selected channels The Event List displays as follows Event List No Date Time Ch Type 1 2005 03 17 11 26 50 2 Motion 2 2005 03 17 09 53 03 5 Alarm 3 2005 03 16 16 14 42 3 Alarm 4 2005 03 15 03 45 31 1 Motion 5 2005 03 12 22 27 56 1 Alarm 6 2005 03 12 10 09 29 7 Motion 7 2005 03 11 12 18 20 6 Motion 8 2005 03 10 05 16 00 4 Alarm 9 2005 03 08 17 11 37 2 Motion 10 2005 03 08 16 29 10 8 Motion 11 2005 03 08 03 22 17 2 Alarm The list displays each event by date time triggered camera and alarm type Please note that the event list displays only the first 1024 events as some events are deleted others are displayed The latest recorded event video will be listed on the top To exit the event list press ESC Follow the steps to playback video from event list e Use UP DOWN to scroll through the Event List e Press ENTER to play back the selected event record e Press PLAY STOP or ESC to return to live mode 4 4 Deleting Recorded Video User can delete the Normal a
6. lt Standard gt lt Extended Record gt lt Event Only gt lt 128Kbps DSL 256Kbps DSL 512Kbps DSL and OFF According to various Record modes the preset configuration options for normal and event status are described in terms of relative recording rate PPS and recording size for each channel in the table below The preset conditions Best Quality Standard Extended Record Event Only 128Kbps DSL 256Kbps DSL and 512Kbps DSL override any other quality and rate settings The default Preset Configuration setting is Standard Record Mode Full D1 mode NTSC 720x480 30PPS PAL 720x576 25PPS Preset Normal Normal Event Event Event Active Configuration PPS Size PPS Size SES e PAD TARD SPAL Ieka ene Maii Standard CER 9 KB eee AD 13 KB Both SEES wm SP Event Only ce bo ee SC 13 KB Both 128Kbps DSL i AE 2 KB ce Se 2 KB Both 256Kbps DSL GE AD 2 KB Up SE 2KB Both 512Kbps DSL ie hts 3 KB APAL 3 KB Both www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual User User User User Selected Selected Selected Selected User selected OFF NOTE If selecting this Record mode only the image from channel 1 4 will be recorded Record Mode Half D1 mode NTSC 720x240 60PPS PAL 720x288 50PPS Preset Normal Normal Event Event Event Active Configuration PP
7. Close SEQ FREEZE Focus Near Far MENU SEARCH Zoom In Out ENTER Auto Focus Iris lt A Y b Pan Tilt CH1 Set Go Preset CH2 Hint Screen On Off Dome Control e Press 1 to access the Set Go Preset function The Dome Preset menu is displayed Dome Preset Index Set Preset Go Preset 1 NO NO 2 NO NO 3 NO NO 4 NO NO 5 NO NO 6 NO NO 7 NO NO e Use UP DOWN buttons to select the desired preset number from the menu e Set the Set Preset gt of the selected preset number to lt YES gt and press ENTER to save the position Now the preset is set and ready to call 4 6 6 Calling Preset Points Follow the steps to call preset points e Press a Channel key to view the corresponding camera in full screen e Then press DOME to enter dome control mode e Press 2 to view the dome control Hint Screen press 2 again to toggle the Hint Screen e Press 1 to access the Set Go Preset function 48 www dynacolor com tw All rights reserved DYNACOLOR Ke Index NOOR WD A Dome Preset Set Preset Go Preset User s Manual e Use UP DOWN buttons to select the desired preset number from the menu e Set the Go Preset gt of the selected preset number to YES and press ENTER to call the preset point e Now the selected dome camera rotates to the preset position automatically www dynacolor com tw All rights reserved 49 User s Manual 9 5 1 50 DYNACOL
8. The item is for setting the IP address that identifies the DynaGuard 200 series unit over modem connection Move the cursor over lt Server IP gt and press ENTER and then press UP DOWN buttons to change the values in the selected field Client IP The item determines the remote PC s IP address for connecting with the DynaGuard 200 series unit Move the cursor over Client IP and press ENTER and then press UP DOWN buttons to change the values in the selected field Dial in Idle Time This item indicates the longest amount of time that the modem connection remains active if there is no acknowledgement from the remote pc The value can be set in the range of 1 min to 600 min If selecting OFF the modem connection keeps active continuously Dial in Max Time The item indicates the longest amount of time that the connection via modem remains active The value can be set in the range of 1 min to 600 min or OFF to keep the connection indefinitely www dynacolor com tw 61 All rights reserved User s Manual 5 1 6 4 62 DYNACOLOR Ke Dial out Setup The Dial out function enables user to establish dial up modem communication to and from DynaGuard 200 series unit for remote notification use User can connect one modem to DynaGuard 200 series unit For more information on dial up setting on PC see Appendix C Dial up Connections via Modem NOTE Do not enable the Dial out Service if no modem con
9. c 65 le etc ott bee dint Eo utn tr directi in aiei 65 SMIP SCUD Ee 66 z 0E Ec ARN ro n 66 ci fzEi0 gm RES 66 SMP POR EE 67 SMTP En saencana E 67 SMTP PASSIO E 67 9 User s Manual 5 2 5 3 5 4 DYNACOLOR Ke 5 1 6 8 DDNS Setup E 68 zu Ape S 68 Host E 68 DONS EE 69 OUP EE 69 SA7 ig gt in bo er ee 69 Eu MENT E 69 S2 RE 69 5 1 7 3 E 70 Sie Olene 70 S179 ON terc 70 See Audo OO T 70 SLO OKO BOOD ee eee ees ee eee t 70 Montor Se UI M a 70 521 Show Camera Title NUTS 71 ma Monitor Contrast EE 71 5 2 4 Monitor Chrommmance nennen nennen nnn nnns nnns 71 eg RETI 71 526 Show Color Baf E t tener cent 72 Dar Vo nes Wl EE 72 Camera EE 72 532 Camera EE 73 532 D me Proloco NN 13 99 3 Dome MD EE 73 5 3 4 Camera HERE 73 F COVE Rm 74 5 3 6 Terminato aiccein eai iai EAG 74 E EONS EE 75 Gir e E 75 D99 PEIN E 75 SAM leese santa EE EE 75 551 EENEG 75 Record SAIN M 75 GT Su WE e EE 76 5 4 2 Schedule Setup EE 76 54201 Day Night ime Stam oet pbi bs ubi e ERER 77 5 4 2 2 Weekend Gchedule eese 77 5 4 2 3 Weekend Start End EE Z 54 3 Preset Re E 77 5 4 4 Per Camera tee dE 79 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual 5 4 4 1 Camera E 80 5442 Blois EE 80 544 3 e 80 50145 Event MOX PP Oraison ia 8
10. 15 6 25 740 7 888 9 284 9 341 9 176 4 211 6 127 7 153 3 100 1 120 1 www dynacolor com tw 99 All rights reserved DYNACOLOR Ke User s Manual Appendix C Dial up Connections via Modem A dial up modem connection allows user to use the remote software and receive alarm notice without an internet connection Following are the steps for establishing the connection between a DynaGuard 200 series unit and a PC Establishing Dial in Connection The Dial in function enables user to establish dial up modem communication to and from DynaGuard 200 series unit for the remote software use Follow the description to set up your DVR and PC DVR Configuration e Connect an USB modem to the USB socket and connect a working phone line to the modem e Press MENU and input the Administrator password to access the OSD Main menu Select lt Network Setup gt and then lt Dial in Setup gt to set up the Dial In settings including Dial in Account and password etc e For more information on dial in settings see section 5 1 6 3 Dial in Setup PC Configuration e Click lt Start gt lt My Network Places gt lt View Network Connections gt and then select lt Create New Connection gt The New Connection Wizard is displayed Click lt Next gt to continue New Connection Wizard Welcome to the New Connection A Wizard This wizard helps you Connectto the Internet Connectto a private network such as your workpla
11. 21x13 detection grids in NTSC video format or 336 21 x16 grids in PAL format Use the Direction buttons to move the cursor and press ENTER to enable or disable a grid Press MODE to select all of the grids for detection press MODE again to de select all of the grids Sensitivity The item is used to set the sensitivity of detection grids for the camera A greater value indicates more sensitive motion detection A motion alarm will be triggered once the amount of motion detected exceeds the Threshold value Move the cursor to lt Sensitivity gt and press ENTER and then use UP DOWN buttons to adjust the value The value is indicated in 4 increment Area Threshold Area Threshold means the motion alarm triggered level if the percentage of triggered grids to total detection area is greater than the set value the motion alarm will be triggered www dynacolor com tw 87 All rights reserved User s Manual 5 6 5 5 5 6 5 6 5 7 88 DYNACOLOR Ke For example if 10 grids are selected and the lt Area Threshold gt value is 70 the motion alarm will be triggered when seven grids are motion detected Move the cursor to lt Area Threshold gt and press ENTER and then use UP DOWN buttons to adjust the value The value is indicated in 4 increment Detected Area Percentage The part shows the percentage and variation of the detected volume Alarm In This item allows user to enable disa
12. For all sites in this zone e Click lt OK gt to confirm the setting and close Trusted sites dialog e n the Security Level area click Custom Level The Security Settings screen is displayed 114 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Security Settings Settings wl ActiveX controls and plug ins Automatic prompting For Activex controls Disable Enable A Binary and script behaviors Administrator approved Disable Enable Iw Download signed ActiveX controls Disable Enable Prompt A Download unsigned Activex controls E Reset custom settings e Under lt All ActiveX controls and plug ins gt set all items to lt Enable gt or lt Prompt gt e Click lt OK gt to accept the settings and close the lt Security gt screen e Click lt OK gt to close Internet Options dialog Now you can continue with the rest of the DynaRemote installation 3 2 Installing Remote Software Start the browser to initiate the installation of DynaRemote on your personal computer You can save the IP address of the remote unit as a Favorites item in your web browser to have easy access next time e Start the IE you may start it either by clicking on the desktop icon or by using the Start menu to access it e Enter the IP address of your DynaGuard 200 series unit in the address field where is at the top of the browser e The ActiveX controls and plug in
13. to cancel Select Video After selecting video clips set the item Begin Export to YES and press ENTER to start exporting Following are the items for selecting video Select Channel Select the channel that the administrator wants to export Move the cursor to the wanted channel using LEFT RIGHT buttons select or de select a channel by pressing ENTER From To Time The items are used to set the time which data export begins and ends Move the cursor using Direction buttons and press ENTER to select the date time items adjust the selected date and time value by UP DOWN buttons www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual NOTE The exported data between the Start Time and End Time includes both normal and event video Select Events Select the item to display the event list for exporting event video Move the cursor scroll the event list and press ENTER to select the event you want to export Data Type The item is used to select exporting video type The options are lt Normal gt export normal video only lt Event gt export event video only and lt Both gt export both normal and event video Export Format The item is for selecting exporting video format The options are lt DRV gt and lt AVI gt The drv file can only be played back with DynaRemote and DynaPlayer and multiple camera video can be played from one file The avi file can be played back with
14. 6 Alarm Out None 5 6 5 1 Channel Select The item is used to select a desired channel for setting the parameters Move the cursor to Channel Select and press ENTER then select a channel using UP DOWN buttons Press ENTER again to confirm the setting 5 6 5 2 Video Loss Detect This item allows user to enable disable Video Loss as an alarm event Select lt ON gt to enable Video Loss alarm events lt OFF gt to disable The default setting is lt ON gt 5 6 5 3 Motion Detect Use to enable or disable the motion detection function of the DynaGuard 200 series By default the value is lt OFF gt If motion detection function is enabled it is required to define the motion detection parameters such as detection area and sensitivity settings 5 6 5 4 Detection Configuration If motion detection function is enabled it is required to define the motion detection parameters such as detection area and sensitivity settings Select a desired channel for setting the parameters move the cursor to lt Detection Config gt and press ENTER The Detection Configuration menu displays as follows 86 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Detection Config 1 Detected Area Setup 2 Sensitivity 75 3 Area Threshold 60 Detected Area Percentage 40 Detected Area Setup The Detect Area is displayed as follows after selecting this item The detection area consists of 273
15. Alarm Input 4 alarm inputs Alarm Output 2 relay outputs Video Loss Detection Automatic Covert camera Yes Display options 1 2x2 3x3 View live or playback while recording Yes Live update speed 4CH 120 pps NTSC 100 pps PAL 8CH 240 pps NTSC 200 pps PAL Live image resolution 720x480 NTSC 720x576 PAL Record resolution amp Record speed NTSC PAL selectable selectable 720x480 30pps 720x576 25pps 720x240 60pps 720x288 50pps 360x240 120pps 360x288 100pps Audio capability 2 channels record amp playback 8 KHz 16 bits ADPCM Compression Image size 1K 13K Byte picture Pre alarm recording 5 to 30 sec Motion detection Yes Record modes Linear circular Internal Storage x2 ATA 133 HDD UDMA133 IDE HDD External off line storage USB 2 0 port x3 or IEEE 1394 FireWire for ThumbDrive CD RW DVD dual Dome Control Protocols DynaColor Pelco P Pelco D AD422 Ethernet 10 100M RJ45 DHCP PPPoE DDNS full support www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual RS232C D Sub 9 pin female RS485 Terminal block Authentication Digital signature on export Remote Software DynaRemote software included Operating Temperature 0 40 C Unit Dimension WxHxD 210x88x330 mm 8 3x3 4x13 inches Unit Weight Approximate 4 kg 8 8
16. DYNACOLOR Ke previously recorded video and stores new video over the HDD spaces If you choose to record in linear mode in stead the unit stops recording when the HDD is full Select ON to record video in circular mode or OFF in linear mode Audio Recording This item allows user to enable disable Audio recording function of the unit When set to ON audio input is recorded and saved with the video When set to OFF audio is ignored The default setting is ON Event Setup The Event Setup menu allows user to determine DynaGuard 200 series units behavior in response to an alarm event Click MENU button on the main window toolbar and click the plus icon to expand the Event Setup menu System Setup Monitor Setup Camera Setup Record Setup Internal Buzzer Event Icon Email Notice Event Duration Per Channel Config Internal Buzzer This item allows user to enable disable the unit s internal buzzer If set to ON the buzzer is activated in response to an alarm If set to lt OFF gt the buzzer is not activated The default setting is ON Event Icon The item enables ON disables OFF the display of Event Icon on the monitor when an alarm event occurs The default setting is ON The event types are represented by a character respectively the descriptions are as below table www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual
17. Dial out Max Time The item indicates the longest amount of time that the connection via modem remains active The value can be set in the range of 1 min to 600 min or lt OFF gt to keep the connection indefinitely Connect When the Dial out related settings are configured set this item to lt YES gt to starting dial out or select lt NO gt to disconnect Trigger Port To avoid the default service port port 80 to be blocked the item enables user to change port 80 into another port To change the trigger port move the cursor over lt Trigger Port gt and press ENTER then adjust the setting by UP DOWN buttons Email Address This item is used to edit the e mail address where alarm event information will be sent Follow these steps to setup the e mail address e Select lt Email Address gt from Network Setup menu and press ENTER A virtual keyboard displays e Use Direction buttons to move the cursor for selecting character e Press ENTER to add the selected character to the password entry field e When done move the cursor to lt OK gt and press ENTER to save the settings and exit www dynacolor com tw 65 All rights reserved User s Manual 5 1 6 7 66 DYNACOLOR Ke SMTP Setup Simple Mail Transfer Protocol SMTP a protocol for sending e mail messages between servers SMTP is a relatively simple text based protocol where one or more recipients of a message are specified and the message text is tran
18. IEEE 1394 FireWire x2 The DynaGuard 200 series is equipped with two IEEE 1394 FireWire ports for extended connections PAL NTSC Switch The video standard switch is for qualified service personnel only www dynacolor com tw 21 All rights reserved User s Manual 3 3 1 3 1 1 22 DYNACOLOR Ke General System Setup The DynaGuard 200 series allows user to access some general operations through the front panel easily The following sections introduce the general operations of the unit The generally displayed OSD information and its position are shown in the following figure Camera Title Operating Mode Date Time Front Panel The unit s front panel controls enable user to control the unit and preset the programmable functions The 8 channel DynaGuard 200 series unit front panel has eight keys for eight channels respectively The LED and function keys will be introduced by name and function in following sections LED Definition The DynaGuard 200 series LEDs on the front panel are described as follows DYNAC LOR Te disc UH Recordable i 4 i i Power Network Alarm REC HDD www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Power LED Green The LED lit when the correct power is connected Network LED Green The LED should be lit when DynaGuard 200 series is connected to a network and blink when the data is being transferr
19. Ibs Shipping Dimension WxHxD 350x180x420 mm 13 8x7 1x16 5 inches Shipping Weight Approximate 5 kg 11 Ibs Power Consumption amp Input AC 100 240V 35W 50 60Hz www dynacolor com tw All rights reserved 97 User s Manual Appendix B Record Duration DYNACOLOR Ke The record duration relates to recording rate image quality and HDD capacity Refer to the following table NOTE Record duration times are based on actual tests and represent average file sizes Performance may vary depending on specific installations and use Audio recording requires 8 KB per second or 0 7 GB per day for data storage Please refer to our recording time calculator on the DynaColor website for other possible calculations http www dynacolor com tw gt Support gt Tools Number of Days of Recording 30PPS without Audio Recording Rate Total Images Per Second NTSC Total Images Per Second PAL 160 GB Internal Storage Recording Picture Quality Mode Extended Basic Normal High Superior NTSC PAL NTSC PAL NTSC PAL NTSC PAL NTSC PAL 5 KB 5 KB 7 KB 7 KB 9 KB 9 KB 11 KB 11 KB 13 KB 13 KB 60 50 5 9 7 1 4 3 5 1 3 3 4 0 2 7 3 3 2 3 2 8 30 25 11 8 14 1 8 5 10 2 6 7 8 0 5 5 6 6 4 7 5 6 15 12 5 23 5 28 2 17 0 20 4 13 3 16 0 11 0 13 2 9 3 11 2 LS 6 25 47 0 5
20. Monitor Setup Day Time Start AM 06 00 zzzi p eee Night Time Start men Record Setup Schedule Setup Weekend Schedule YES m Preset Config Per Camera Config Weekend Start PM 06 00 a Event Percentage Data Lifetime Fri I Pre Alarm Recording Weekend End amoo Circular Recording Audio Recording Sequence Setup Event Setup Mon X Jf OK X Cancel Apply e Day Night Time Start The Day Night Start Time determines the beginning of day night recording time Time is indicated in 1 minute increments The time display format is based on the setting of Time Display Mode e Weekend Schedule The Weekend Schedule determines whether a weekend schedule is in effect Choose lt YES gt to take effect the related weekend settings e Weekend Start End The Weekend Start Time indicates the specific day and time that a weekend begins for example FRI 18 00 The Weekend End Time www dynacolor com tw 141 All rights reserved User s Manual 5 4 2 142 DYNACOLOR Ke indicates the specific time and day that a weekend ends for example MON 06 00 Time is indicated in 1 minute increments Note that the value you have set indicates when the regular Day and Night scheduling ends and Weekend recording begins Preset Configuration The lt Preset Config gt is used to select the preset recording quality and frame rate Different default recording quality levels are offered for user to choose lt Best Quality gt
21. NO termination resistor disabled NOTE If the camera loop out connectors have not been used the termination resistor should be enabled for appropriate signal termination www dynacolor com tw All rights reserved DYNACOLOR Ke 5 3 7 5 3 8 5 3 9 5 3 10 5 3 11 5 4 User s Manual Brightness Move the cursor to the item and press ENTER for adjusting the brightness darkness of image displayed on the monitor Use UP DOWN buttons to adjust the numeric value The range of brightness values is lt 128 gt to 127 The default setting is 0 Contrast Move the cursor to the item and press ENTER for adjusting the contrast of image displayed on the monitor Use UP DOWN buttons to adjust the value Saturation Move the cursor to the item and press ENTER to adjust the color saturation displayed on color monitor using UP DOWN buttons This value is ignored on monochrome monitors The range of saturation values is lt 128 gt to lt 127 gt The default setting is 0 Hue Move the cursor to the item and press ENTER for adjusting the hue of image displayed on the monitor Use UP DOWN buttons to adjust the value Audio Association The item is used to establish the connection between the selected camera and the two audio in channels Move the cursor to Audio Association in Camera Setup menu and press ENTER then select Both Left Only gt Right Only or None by UP DOWN keys to se
22. Temporary Internet Files field the screen displays as below Delete Files A Delete all files in the Temporary Internet Files You can also delete all your offline content stored locally e Enable the lt Delete all offline content gt and click lt OK gt e Now enter the IP address of your DynaGuard 200 series unit to make the connection again 150 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Appendix A Setting up a DVR behind a Router This appendix describes how to set up a router if the DVR connects to the internet via a router To properly operate a web server e g a DVR the user has to set up both the IP and port of the DVR which are essential for data and command transmission The port setting is adjustable in OSD setup menu of DVR and only one port is needed to do remote operation Typically and by the default the DVR operates on port 80 which is well known as the http port Please make sure that port 80 is not blocked by your ISP or you will have to find another available port and change the setting of the DVR wat Internet tuy DVR 1 192 168 0 10 Remote User In case a router or sometimes a DSL modem is in place the real IP is now assigned to the router instead of the DVR The DVR is located behind the wall router and operates on virtual IP In most cases virtual IP starts with 192 168 x x The router has two IPs one is real IP WAN IP the other is virtu
23. and User passwords The factory password is 1234 for administrator and 4321 for user Network Setup Expand the Network setup menu by clicking the plus icon The expanded Network Setup menu displays as below CG System Setup Language Date Time Unit Name Password Network Setup SMTP Setup DDNS Setup R5485 Setup Audio Output Key Beep Monitor Setup Camera Setup Record Setup Event Setup www dynacolor com tw 133 All rights reserved User s Manual 134 DYNACOLOR Ke Email Address This item is used to edit the e mail address where alarm event information will be sent Enter the e mail address directly using keyboard SMTP Setup Click lt SMTP Setup gt to display the SMTP Setup menu It allows user to configure the SMTP related settings Configuration System Setup Language Email Via SMTP Date Time Unit Name Password SMTP Port Network Setup Email Address SMTP Account SMTP Setup SMTP Password DDNS Setup SMTP Server R5485 Setup Audio Output Key Beep Monitor Setup Camera Setup Record Setup Event Setup X Cancel PO Apply Email via SMTP The item enables user to determine if the unit sends e mail via SMTP Select lt YES gt to send e mail via SMTP if not select lt NO gt SMTP Server The item allows user to setup the SMTP server SMTP Port The item is used to change SMTP port into another port if necessary SMTP usually is implemented to op
24. indicates the specific day and time that a weekend begins for example FRI 18 00 The Weekend End Time indicates the specific time and day that a weekend ends for example MON 06 00 Time is indicated in 1 minute increments Note that the value you have set indicates when the regular Day and Night scheduling ends and Weekend recording begins 5 4 3 Preset Configuration The lt Preset Config gt is used to select the preset recording quality and frame rate Different default recording quality levels are offered for user to choose lt Best Quality gt lt Standard gt lt Extended Record gt lt Event Only gt lt 128Kbps DSL gt lt 256Kbps DSL gt lt 512Kbps DSL gt and lt OFF gt According to various Record modes the preset configuration options for normal and event status are described in terms of relative recording rate PPS and recording size for each channel in the table below www dynacolor com tw 77 All rights reserved User s Manual 78 DYNACOLOR Ke The preset conditions lt Best Quality gt lt Standard gt lt Extended Record gt lt Event Only gt lt 128Kbps DSL gt lt 256Kbps DSL gt and lt 512Kbps DSL gt override any other quality and rate settings The default Preset Configuration setting is lt Standard gt Record Mode Full D1 mode NTSC 720x480 30PPS PAL 720x576 25PPS Preset Normal Normal Event Event Event Active Configuration PPS Size PPS Size SES
25. media players Note that if multiple channels are exported each channel is exported to a separate file 4 5 3 Digital Signature User can export video clip with or without a digital signature Set the item to lt YES gt to export with the signature file or lt NO gt exports without the signature file Each recorded video with digital signature will be exported into four files including gpg avi sig and readme txt The gpg file name is as the last eight MAC Media Access Control address of the unit Make sure that you have an external storage device such as a USB Hard Drive or USB ThumbDrive available and connected to the appropriate port for export For more information on verifying digital signature see Appendix D Verifying Digital Signature www dynacolor com tw 43 All rights reserved User s Manual 4 5 4 4 6 4 6 1 44 DYNACOLOR Ke Erase Disc This function is used to remove information found on a CD RW or DVD RW disk prior to exporting new information to the drive Select lt YES gt and press ENTER to start deleting data Dome Control DynaGuard 200 series unit allows user to control a dome camera by the front panel In Live mode user can press CHANNEL button to display the desired dome camera in full view To enter Dome Control mode press the DOME button and press channel key 2 to display the hint screen to exit the Dome Control mode and back to live mode press ESC or DOME To
26. playback video FREEZE e The live video will be frozen if press FREEZE while viewing live image but the date time information shown on the monitor will continue updating Press FREEZE again to return to live mode e The playback video will be paused If press FREEZE when playing the recorded video Press LEFT RIGHT to resume playback video single step reverse forward respectively Press FREEZE again to continue playing video SEARCH In both Playback and Live mode user can press SEARCH to call the Search menu for searching and playing back recorded video by date and time or events www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual ESC Press to cancel or exit from certain mode or OSD menu without changing the settings Direction Buttons e n Zoom mode these keys function as Direction buttons e Inthe OSD menu the Direction keys are used to move the cursor to previous or next fields To change the value in the selected field press UP DOWN keys ZOOM ENTER e n OSD menu or selection interface press the button to make the selection or save settings e n both live and playback full screen view mode press to view a 2x zoom image press it again to return e n playback mode the recorded video can be zoomed and moved to view more area 3 2 Power Up Down the Unit If you must shut down the DynaGuard 200 series for any reason please use the proper shut down and power up
27. procedures to avoid damage to your unit To Power Up the Unit Check the used type of power source before plug in the unit first and turn on the unit using the power switch on the rear panel The color bar and system checking information are shown on the monitor until the unit is completely started To Restart Shutdown the Unit Press MENU and input the administrator password to access the OSD Main menu Select lt Shutdown gt in Main Menu and press ENTER to enter the Shutdown menu which displays as follows Shutdown 1 Power Off 2 Reboot www dynacolor com tw 25 All rights reserved DYNACOLOR Ke User s Manual 3 3 26 lt Power Off gt Select this item to shut down the unit Do not remove the power during shut down until the message You can safely turn off DVR now displays lt Reboot gt Select this item to reboot the unit The color bar and system checking information are displayed on the monitor until the unit is completely restarted Entering OSD Setup Menu The OSD Main menu contains a list of items that are used to configure the DynaGuard 200 series To enter the Main menu press MENU and then enter Administrator or User password The Password Verification screen displays as follows Password Verification Press Channel Keys To Enter Password 4 8 Digits Press lt Key To Delete The default passwords are shown in the following table The same passwords are used for entering th
28. the event you want to export Data Type The item is used to select exporting video type The options are lt Normal gt export normal video only lt Event gt export event video only and lt Both gt export both normal and event video NOTE You will not be allowed to access the lt Select Events gt if the Data Type is set to lt Normal gt Export Format The item is for selecting exporting video format The options are lt DRV gt and lt AVI gt The drv file can only be played back with DynaRemote and DynaPlayer and multiple camera video can be played from one file The avi file can be played back with media players Note that if multiple channels are exported each channel is exported to a separate file Digital Signature The Digital Signature function enables user to export video clip with the unit s unique signature key It aims to authenticate a video clip exported from the unit User can export video clip with or without a digital signature file sig Set the item to lt YES gt to export with the signature file or lt NO gt exports without the signature file Make sure that you have an external storage device such as a USB Hard Drive or USB ThumbDrive available and connected to the appropriate port for export For more information on verifying digital signature see Appendix D Verifying Digital Signature www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual
29. to access this function Set Speed Dome X Protocol v www dynacolor com tw 121 All rights reserved User s Manual 4 2 4 2 1 4 2 2 122 DYNACOLOR Ke Focus Use to adjust the camera lens to focus on objects for a clear view Click the adjusting buttons to modify the focus setting Iris This item is used to open and close the iris to let more or less light into the camera Click the adjusting buttons to modify the iris setting Zoom You are allowed to zoom in or zoom out using the adjusting buttons Zoom in to view less area and zoom out to view more area Direction Buttons These buttons are used to pan and or tilt the dome camera Click the arrow button in the direction you want to view Instant Recording The Instant Recording function allows you to record video quickly on your PC Recording Video Instantly pare seca Follow the steps to start recording instantly Col D e Click on the lt Instant Recording gt button e Select the destination you want to save the video e Click on the button again to stop recording NOTE The instant recording video will be saved as drv file To Playback Instant Recording Video Follow the steps to playback a video recording instantly e Click lt Play gt on main window toolbar and click lt Local Playback gt tab e Click lt Open gt to choose a file recorded e Click lt OK gt to start playing the recorded video www dynacolor com tw All rights
30. to enable or disable the Dynamic Domain Name Service Select lt YES gt to enable the service or lt NO gt to disable Host Name The item allows user to setup a domain name which is used when entering the DynaGuard 200 series unit through the net on your remote PC To setup the Host Name of the unit follow the steps e Select lt Host Name gt from DDNS Setup menu and press ENTER A virtual keyboard displays as below figure Host Name A BCD F GH iI J M O QRS TUVWX Y Z abcde fgh ij m n o q r s u v w x yz 012 3 4 5 6 7 8 ar gt Backspace Delete Cancel OK e Use Direction buttons to select character www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual e Press ENTER to add the selected character to the password entry field e When done move the cursor to lt OK gt and press ENTER to save the settings and exit NOTE No any two DynaGuard 200 series units should be set the same Host Name DDNS Port The item allows user to setup the port for DDNS Press UP DOWN Direction buttons to change the port Submit Update When done move the cursor to this item and press ENTER to submit the settings NOTE If there are two DynaGuard 200 series units set the same domain name the later setting will not be submit successfully 5 1 7 RS485 Setup This menu allows setting up the parameters of the units RS 485 communications port From the Main menu select R
31. 0 Le Ao EVEN 1 cR 80 DAAG Event ACV en 81 54 5 Event Percentage RET 81 546 Data OH 81 DAF Pre Alarm RECOMING E 81 aan AN NO NG D 82 54 9 Audio E 82 54 10 US 18 EE 82 54 101 Purge All Normal eat atthe eebe 82 9410 2 PurgS All Event E 83 5 4 10 3 Purge Event Before EE 83 5 4 10 4 Purge Event EE 83 54 10 5 Start to PUJO NERO TE UIT 83 959 Seduente lUo rer 83 5 5 1 Main Call Monitor Dwell c 84 onc Mains Call Monitor aaen ent eeneg 84 POE 0000 00 TT 84 so BD e RE 85 5602 Event OO RE 85 SOR EE So cd ONG E sno a DS RE METUO 85 5 6 4 Event DUNMOW EE 85 COM ett es RAI TNC EE 86 5 6 5 1 Channel BSC E 86 soc Video Loss WEE 86 5 69 39 E ee RE 86 56 54 Detection COMMUN ON EE 86 Detected Area EE 87 SE 87 Area Threshold E 87 Detected Area Percentage c eeceeeeeeeeeeneeeenenens 88 5655 Alatri nb 88 5096 Alam OUl cnie T 88 57 Database SEINE siressa sued dcabdacidadidankducheacitadidoebtadhdeebiadbieaidaaidadids 88 57 1 Totaly Free Size of HDD E 89 572 RestNormal Event REC RT 89 Bolo intemal Beda DISKS enee e EE 89 www dynacolor com tw 11 All rights reserved User s Manual 5 8 Configuration E 5 8 1 Load Factory Detail iau et bra bebe bred ne Ree Te E 593 Export KREIEN sacantcindcantisadeantssndinndicndeantacnds 55 91 C py RE E 5 8 3 2 Configuration Ne ose e bios 50 9 80 Begin ER E S99 Vdeo e E 5 9 1 Select Device si cccccciccnccsnanamenanizamensne
32. 5 6 25 142 5 170 9 88 2 105 8 63 9 76 6 50 1 60 1 41 2 49 4 60 50 35 6 42 7 22 0 26 5 16 0 19 2 12 5 15 0 10 3 12 3 30 25 71 2 85 5 44 1 52 9 31 9 38 3 25 0 30 0 20 6 24 7 15 12 5 142 5 170 9 88 2 105 8 63 9 76 6 50 1 60 1 41 2 49 4 7 5 6 25 284 9 341 9 176 4 211 6 127 7 153 3 100 1 120 1 82 3 98 8 Number of Days of Recording 120PPS without Audio Recording Rate Recording Picture Quality Mode Total Images Total Images Extended Basic Normal High Superior Per Second Per Second NTSC PAL NTSC PAL NTSC PAL NTSC PAL NTSC PAL NTSC PAL 1 KB 1 KB 3 KB 3 KB 5 KB 5 KB 7 KB 7 KB 9 KB 9 KB 60 50 24 7 29 6 9 5 11 4 5 9 7 1 4 3 5 1 3 3 4 0 30 25 49 4 59 3 19 0 22 8 11 8 14 1 8 5 10 2 6 7 8 0 15 12 5 98 8 118 5 38 0 45 6 23 5 28 2 17 0 20 4 13 3 16 0 7 5 6 25 197 5 237 00 76 0 91 2 47 0 564 34 1 40 9 26 7 32 0 300 GB Internal Storage 60 50 46 3 55 6 17 8 214 11 0 13 2 8 0 9 6 6 3 7 5 30 25 92 6 111 1 35 6 42 7 220 26 5 16 0 19 2 12 5 15 0 15 12 5 185 2 222 2 71 2 85 5 44 1 52 9 31 9 38 3 25 0 30 0 7 5 6 25 370 4 444 4 142 5 170 9 88 2 105 8 63 9 76 6 50 1 60 1 600 5 oraq 60 50 92 6 111 1 35 6 42 7 220 26 5 16 0 19 2 12 5 15 0 30 25 185 2 222 2 71 2 85 5 44 1 52 9 31 9 38 3 25 0 30 0 15 12 5 370 4 444 4 142 5 170 9 88 2 105 8 603 9 76 6 50 1 60 1
33. 6 4 34 1 40 9 26 7 32 0 21 9 26 3 18 6 22 4 60 50 11 0 13 2 8 0 9 6 6 3 7 5 5 1 6 2 4 4 5 2 30 25 22 0 26 5 16 0 19 2 12 5 15 0 10 3 12 3 8 7 10 5 15 12 5 44 1 52 9 31 9 38 3 25 0 30 0 20 6 24 7 17 5 21 0 7 5 6 25 88 2 105 8 63 9 76 6 50 1 60 1 41 2 49 4 34 9 41 9 DUU 5 O o 60 50 22 0 26 5 16 0 19 2 12 5 15 0 10 3 12 3 8 7 10 5 30 25 44 1 52 9 31 9 38 3 25 0 30 0 20 6 24 7 17 5 21 0 15 12 5 88 2 105 8 63 9 76 6 50 1 60 1 41 2 49 4 34 9 41 9 7 5 6 25 176 4 211 6 127 7 153 3 100 1 120 1 82 3 98 8 69 9 83 9 Number of Days of Recording 60PPS without Audio Recording Rate Recording Picture Quality Mode Total Images Total Images Extended Basic Normal High Superior Per Second Per Second NTSC PAL NTSC PAL NTSC PAL NTSC PAL NTSC PAL NTSC PAL 3 KB 3 KB 5 KB 5 KB 7 KB 7 KB 9 KB 9 KB 11 KB 11 KB 98 www dynacolor com tw All rights reserved DYNACOLOR Ke 160 GB Internal Storage User s Manual 60 50 9 5 11 4 5 9 7 1 4 3 5 1 3 3 4 0 2 7 33 30 25 19 0 22 8 11 8 14 1 8 5 10 2 6 7 8 0 5 5 6 6 15 12 5 38 0 45 6 23 5 28 2 17 0 20 4 13 3 16 0 11 0 13 2 7 5 6 25 76 0 91 2 47 0 56 4 34 1 40 9 26 7 32 0 21 9 26 3 60 50 17 8 21 4 11 0 13 2 8 0 9 6 6 3 7 5 5 1 6 2 30 25 35 6 42 7 22 0 26 5 16 0 19 2 12 5 15 0 10 3 12 3 15 12 5 71 2 85 5 44 1 52 9 31 9 38 3 25 0 30 0 20 6 24 7 7
34. ALAchO1 DD avi Filename sig N 20050602 135607 NORMAL ch01 00 sig Status Log e The result of verify shows in the lt Status Log gt field It returns a GOOD or BAD signature result A GOOD signature indicates the exported clip has not been altered Playback Remote Playback Local Playback Filename gpg N 20050602 1 35607389641062 gpg Filename avi NAZOOS0602 135607 NORMAL chO1 00 avi Filename sig N 20050602 135607 NORMAL ch01 00 sig Status Log Verified Good signature from 00D089641062 GOOD Signature 128 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual 5 Configuring the Remote Unit Click MENU button on the toolbar to configure a DynaGuard 200 series unit remotely The Configuration menu displays as below Configuration System Setup Monitor Setup Language English Y Camera Setup Record Setup Event Setup X Cancel Configuration Menu The Configuration menu contains a list of items that are used to configure DynaGuard 200 series units remotely The following subsections describe the configuration items and buttons used in the OSD menu AN NOTE The settings in Configuration menu only apply to the unit The Administrator can perform unit configuration freely If you log in DynaRemote using User account the most settings will be read only and cannot be configured NOTE If an Administrator ac
35. B Both 128Kbps DSL QE 2KB dp Ps 2 KB Both 256Kbps DSL Pi 2 KB er GE 2 KB Both 512Kbps DSL Mis 3KB e ep 3 KB Both SS S Sec Soe Seeacd Uer selected 3 5 4 Per Camera Configuration This function is used to set the Day Night Weekend PPS Picture per Second and Quality for each channel The Preset Configuration must be set to lt OFF gt for accessing these schedules The menu is displayed as below Record Mode 720x240 60PPS in NTSC 720x288 50PPS in PAL Cameral Select Normal PPS Normal Size Event Max PPS Event Size Event Active Per Camera Config Day Night 7 5 7 5 7KB 7KB 30 30 11KB 11KB Both Both CH1 Weekend 7 5 7KB 30 11KB Both www dynacolor com tw All rights reserved 33 User s Manual 34 DYNACOLOR Ke e Firstly select a Camera for setting its record configuration The image and recording settings from the selected camera will be displayed on the screen e Move the cursor using Direction buttons and press ENTER to select an item e Change the value using UP DOWN buttons e Press ENTER to confirm the settings or ESC to abort e Press ESC to return to Record Setup menu Please note that the total normal pps for all channels cannot exceed 60 NTSC 720x240 60PPS 50 PAL 720x288 50PPS To increase one channel s pps you may have to reduce other s first Event pps is not restricted to this rule since a smart event scheduler will handle to
36. C BNC Camera Looping Video Input LAN Switch Jack Main Monitor Audio Audio Alarm HO VGA Out RS232C USB IEEE PAL NTSC S Video In Out amp RS485 1394 Switch www dynacolor com tw 19 All rights reserved User s Manual 20 DYNACOLOR Ke Main Monitor S Video BNC Both S Video and BNC output connectors are offered for connecting to a main monitor The main monitor displays live image and playback recorded video in full screen or split window format Call Monitor BNC The call monitor is used to display full screen video of all installed cameras in sequence The BNC call monitor connector allows user to connect the DynaGuard 200 series unit with an optional call monitor Video Input 4 or 8 BNC connectors are offered for video input streams from installed cameras The number of connectors is equal to the number of channels Camera Looping Plenty of BNC connectors are positioned on the real panel for looping out the video input The number of these connectors is equal to the number of channels 4 channel 8 channel DynaGuard 200 series unit has 4 8 camera looping connectors respectively LAN Connector RJ 45 The DynaGuard 200 series is capable of networking The LAN port opens the door of DynaGuard 200 series to Ethernet where by the Internet Power Jack The DynaGuard 200 series has a free voltage AC power connection jack Please connect the power supply that ships with the unit WARNING
37. CH2 CH3 CH4 3 Start Time 2005 03 19 AM 07 50 05 4 End Time 2005 03 28 PM 03 09 18 5 Select Events 6 Data Type Normal 7 Digital Signature NO 8 Erase Disc NO 9 Begin Export NO Each recorded video will be exported into four files with different filenames including gpg avi sig and readme txt To verify the exported recorded video Following are the procedures for digital signature verification e Start your DynaRemote and click Play on the main window tool bar e Click Verify tab to display the Verify window Playback Remote Playback Local Playback Verify Filename gpg mmm E Filename avi M Filename sig Status Log 108 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual e Click lt Browse gt to select the gpg avi sig files respectively which belong to the exported video you want to authenticate My Recent Documents 2 Desktop My Documents My Computer My Network File name 89641052 gpg Y Netw z m Files of type GPG files Cancel e Click lt Verify gt to start verifying digital signature Playback Remote Playback Local Playback Filename gpg N 20050602 135607 8964 1062 gpg j N 20050602 135607 NORMAL ch01 00 sig Status Log e The result of verify shows in the lt Status Log gt field It returns a GOOD or BAD signature result A GOOD signature indicates the expo
38. Do not place this unit on an unstable stand bracket or mount This unit is designed for indoor use only Do not place the unit near water or in other extremely humid conditions This unit should not be placed in a built in installation unless proper ventilation is provided Please check the used type of power source before you plug and operate the unit Unplug the unit from the outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use only a damp cloth for cleaning Always power down the system prior to connecting and disconnecting accessories with the exception of USB devices Lithium battery Danger of explosion if battery is incorrectly replaced Replace with the same or equivalent type recommended by the battery manufacturer Dispose of used batteries according to the battery manufacturer s instructions Do not block the fan on the bottom of the unit for air ventilation CE FC AE CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL www dynacolor com tw 3 All rights reserved DYNACOLOR Ke User s Manual Important Information Before proceeding please read and observe all instructions and warnings in this manual Retain this manual with the original bill of sale for future reference and if necessary warranty service When unpacking your unit check for missing or damaged item
39. DynaG uard 200 Digital Video Recorder amp Dyn a Remote Software Models DG204 DG208 User s Manual Version 1 2 00 3DG200DSEA2 DYNACOLOR Ke User s Manual www dynacolor com tw 1 All rights reserved DYNACOLOR Ke User s Manual Notice The information given in this manual was current when published DynaColor Inc reserves the right to revise and improve its products All specifications are subject to change without notice Copyright Under copyright laws the contents of this user manual may not be copied photocopied translated reproduced or reduced to any electronic medium or machine readable format in whole or in part without prior written permission of DynaColor Inc Copyright 2005 DynaColor Inc Trademarks DynaGuard and DynaRemote are trademarks of DynaColor Inc ThumbDrive is a registered trademark of Trek 2000 International Ltd FireWire is a registered trademark of Apple Computer Inc Windows is a registered trademark of Microsoft Corporation Trademarked names are used throughout this manual Trademarked names are indicated with initial capitalization rather than place a symbol at each occurrence Inclusion or exclusion is not a judgment on the validity or legal status of the term 2 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Caution and Preventive Tips Take care not to drop the unit or subject the unit to major shocks or jolts
40. NR 52 5 1 3 1 Date Time Setting wssiscccccicccssessccstecetecchensssescssteeedetarseadensesccaee 53 Sg Date mme Display cascade chest eneee Eae abc R ER ERRE RRRS 53 5 12 2 Date Display eebe 53 91 34 gesuerg 53 51 35 Date Time Order et 53 5 1 3 6 Daylight Saving Time ee 53 5137 DST Start e senscie oe ee ee eee 54 Sloe e 54 S14 Unt NAME E EEE Eie ENEI 54 Sko PI ecien O AE RRR 55 51 5 1 Admin User PaSsSWOTd EE 55 S92 Enable PassWDE DE 55 5 1 5 3 Load Factory POSS ccc tccccctectcenttecteentiedtnenttadteentiadineatuedttd 56 SO POR Oe EE 56 8 www dynacolor com tw All rights reserved DYNACOLOR Ke 5 1 6 1 2 1 6 2 www dynacolor com tw All rights reserved User s Manual LAN PPPOE E 56 LAIUPPPOE OBL s etr net antec bp peti ii 56 DAOP idi gd ud UEM 57 eebe 57 NetmMaS E 57 E E 58 Ki LE 58 PPPOE ACCOUN E 58 PPPoE Password 59 Giuiho cities 59 Connect At Booting fete C 59 KEE 59 IDISPIEE TEE 59 Bi ET EE 60 KIELEN 60 Dus FP re EE 61 RN Eerad E En 61 Chemt IP ft T 61 Dial in Idle Time EE 61 WIER orc MED RONDE 61 Kr EE 62 8 189 4 ec cape 62 Beet NNI RT 62 Dial o t un 63 Bees 63 Diakout DNS O 63 Phone Rares secadeccicnsdensicecdsssscccdascnestens Mesdensceeateecsenanss 63 BT EE 64 Dial out PASSWONI iiie tine ctl incite nhl oan iediadeds 64 Dial out lee Eegeregie 65 iid E TIM EE 65 CONNECT NEN TE E E m 65 Hic do A
41. OR Ke User s Manual Table of Content DynaGuard 200 Unit De e TE 15 INE i cd Ea ci 1 E T 15 Tas ProductApplication DIGOE Dicis pea sao ON ro bend cds inb ce Esa Fb OUT DK OCDE 17 2 System RE OW T 18 Pee mh Me DIE cecteccteeesce tecoccecteqecce tecoteeeteqectetecoeee teceeeeteceteestecotecetetoueectectes 18 2 2 Selecting Video Pn c M 18 Ad Connecting Devices TO the DIPL neo iibri phe bb bra nr Phe bb bre bri hex ob ERRERA 18 24 Rear Panel Connections ienie eae aa aeaa Eaa Aa E dieses didedidedins 19 Se General System Setup 22 Du Front Pane eseese aei 22 3411 LED DEMON perenn 22 3 1 2 Function Ut hee a en ae ee ee ee ee ee 23 mc Power Ups Dowie acci erdt di oberen tci oid qp pa viv dou 25 s Entering OSD Setup TE TE 26 33 1 Button Usage in OSD Melle bcn ike bte iki x bin ERE ben eub en Reuben bk dde 27 3 3 2 Button Usage in Virtual Keyboard eiae iiconieciine dide iide niae iine bebe 27 24 System D te NO IN asda 28 34 1 S tDate TME emm 28 342 Daylight Saving Eege 29 3 5 Record Schedule Quality Geng 30 S9 Record Fle eee 30 3 5 2 Schedule Setup cccscscscsateteccdercsssatssaraceteastesstesdsecasedisansessasaratanitecadacsenenss 31 45 29 Preset RECO COMMU EE 31 254 Per Camera Cong ellos ded Seege Seeerei Seele 33 4 105 E 35 41 Viewing Live Playback VIOBOIL uaa aacra eara ttc tese abd radi neanetdeeta
42. OR Ke Advanced System Configuration The detailed functions and settings of DynaGuard 200 series can be set using the hierarchical OSD menu This chapter particularizes the items and options in the OSD menu To enter the Main menu press MENU and then enter Administrator or User password The default passwords are shown in the following table The same default passwords are used for entering the remote viewing software DynaRemote Administrator Password User Password 1234 4321 It is strongly suggested to change the passwords to prevent unauthorized access to the unit After entering the correct password the Main menu is displayed Main Menu System Setup Monitor Setup Camera Setup Record Setup Sequence Setup Event Setup Database Setup Configuration Video Export Shutdown Od oo oo0 amp oN 2A System Setup Select System Setup from the Main Menu and press ENTER to enter the System Setup menu System Setup Version Language English Date Time Unit Name DVR Password Network Setup RS485 Setup 8 Audio Output Live Playback 9 Key Beep YES zl OO P Gah A www dynacolor com tw All rights reserved DYNACOLOR Ke 5 1 1 5 1 1 1 S M eg 5 1 1 3 User s Manual The items in the System Setup menu are described in the following sections Version The Version menu allows user to view system information such as hardware
43. Playback gt Select the item to export sounds of live image in live mode and sounds of recorded video in playback mode respectively lt Always Live gt Select the item to export always sounds of live image in both live and playback mode lt OFF gt Select the item to disable the audio output function 5 1 8 Key Beep The item is used to enable or disable the unit s key tone Select lt YES gt to enable the key tone or lt NO gt to disable 5 2 Monitor Setup The Monitor Setup menu allows user to tune the quality of the displayed image Click MENU button on the main window toolbar and click on Monitor Setup to display the menu Configuration l Show Camera Title ps dii Monitor Brightness Event Setup Monitor Contrast Monitor Chrominance YGA Resolution 800 500 X Cancel vf Apply Items listed in Monitor Setup menu are described as below www dynacolor com tw 137 All rights reserved User s Manual 5 3 138 DYNACOLOR Ke Show Camera Title This item allows user to choose whether to display the camera title on the screen or not The default is lt YES gt which displays the camera titles with the video from each camera Monitor Brightness The function allows user to adjust the brightness darkness of image displayed on the monitor Click UP DOWN arrows in the box to adjust the numeric value The range of brightness values is lt 128 gt to lt 127 gt Monitor Contrast The function allows user to adjus
44. S Size PPS Size pestitualty oe Ge TKB pn TURE eae ee Standard ORE 7KB us RE 14 KB Both cs Eed m SIE sig Both Event Only can nas 14 KB Both 128Kbps DSL Kee 2 KB Ge ME 2 KB Both 256Kbps DSL pa 2KB p EE 2 KB Both 512Kbps DSL PA 3KB p NE 3KB Both ae S ce elected etc Use Seletes Record Mode CIF mode NTSC 360x240 120PPS PAL 360x288 100PPS Preset Normal Normal Event Event Event Active Configuration PPS Size PPS Size SSES Hon TEB GEPA ae mee on Standard Be 5 KB P bp 9 KB Both en Idi vm f Both Event Only co 5P SC 9 KB Both 128Kbps DSL i SE 2 KB ae Ps 2 KB Both www dynacolor com tw 143 All rights reserved User s Manual 5 4 3 144 DYNACOLOR Ke ANTSC 4 NTSC 256Kbps DSL 4 PAL 2KB 4 PAL 2KB Both 4 NTSC 4 NTSC 512Kbps DSL 4 PAL 3 KB 4 PAL 3 KB Both User User User User SED Selected Selected Selected Selected User Selected Per Camera Configuration This submenu is used to set the Day Night Weekend PPS Picture per Second and recording quality for each channel The Preset Configuration must be set to OFF for accessing these schedules Normal PPS Normal PPS Picture per Second is used to set the recording rate for normal status Please note that the total normal pps for all channels is limited under the maximum PPS for each Record mode To increase one channel s pps you may have to r
45. S485 Setup and press ENTER The following menu is displayed RS485 Setup 1 Unit ID 224 2 Baud Rate 9600 3 Bits 8 4 Stop 1 5 Parity None 5 1 7 1 Unit ID This item is used to change the RS 485 ID address of the unit The ID is in the range of 1 to 255 The default is lt 224 gt 5 1 7 2 Baud Rate The Baud rate options for associated with the protocol are 2400 4800 9600 19200 and 38400 The default is 9600 baud www dynacolor com tw 69 All rights reserved User s Manual 5 1 7 3 5 1 7 4 5 1 7 5 5 2 70 DYNACOLOR Ke Bits User can specify the bits in a word that are associated with this protocol The available options are lt 6 gt lt 7 gt and lt 8 gt bits The default is lt 8 gt bits Stop User can specify the stop bit associated with this protocol Options are lt 1 gt and lt 2 gt stop bits The default is lt 1 gt stop bit Parity This item is used to specify the parity associated with this protocol Options are lt ODD gt lt EVEN gt and lt NONE gt The default is lt NONE gt Audio Output The item is used to set the audio output mode The available options are as follows lt Live Playback gt Select the item to export sounds of live image in live mode and sounds of recorded video in playback mode respectively lt Always Live gt Select the item to export always sounds of live image in both live and playback mode lt OFF gt Select t
46. Schedule This item is used to set the Main Call Monitor camera sequence in full screen format Move the cursor to lt Main Monitor Schedule gt and press ENTER the menu is displayed as follows Main Monitor Schedule bb b b Press 1 8 Key To Select Channel Press 4 To Delete Follow these steps to set a sequence e Press LEFT direction button to delete the original setting e e Press the desired Channel buttons to assign a camera to that location in the sequence e Continue the steps until the sequence is completed A sequence can have up to eight entries User can select fewer than eight entries for camera sequence and leave the remaining entries blank The sequence can include a specific camera or cameras multiple times Event Setup This menu allows user to determine DynaGuard 200 series behavior in response to an alarm event In the Main menu move the cursor to Event Setup and press ENTER The following menu is displayed Event Setup 1 Internal Buzzer ON 2 Event Icon ON 3 Email Notice ON 4 Event Duration Sec 0 5 Per Channel Config www dynacolor com tw All rights reserved DYNACOLOR Ke 5 6 1 5 6 2 5 6 3 5 6 4 User s Manual Items in the Event Setup menu are described in the following subsections Internal Buzzer This item allows user to enable disable the DynaGuard 200 series internal buzzer If set to lt ON gt the buzzer is activated in respons
47. Use of other power supply may cause overloading Power Switch Used to power up and shut down the unit Audio In Out The DynaGuard 200 series unit provides two channels of audio recording and playback Audio In RCA connector is offered for connecting an audio source device e g external amplified microphone to the unit Audio Out RCA connector is offered for connecting an audio output device e g amplified speakers to the unit www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Alarm I O amp RS485 The unit provides an alarm I O and RS485 port that offers user the flexibility required to connect the unit to the other device Pin Definition Pin Definition 1 Normal Open 1 11 Normal Open 2 2 Common Node 1 12 Common Node 2 3 Normal Close 1 13 Normal Close 2 4 Ground 14 Ground 5 Alarm In 4 15 Alarm In 8 6 Alarm In 3 16 Alarm In 7 7 Alarm In 2 17 Alarm In 6 8 Alarm In 1 18 Alarm In 5 9 RS485 D 19 RS485 D 10 RS485 D 20 RS485 D VGA Out A VGA output connector is offered for connecting to a VGA main monitor The source of image of VGA and BNC main monitor are the same RS 232C The unit provides a RS 232C communication port for sending and receiving signals USB Connector x2 There are two USB2 0 ports on the rear panel for users to connect external USB devices to the unit such as ThumbDrive or CD RW
48. User Selected Per Camera Configuration This submenu is used to set the Day Night Weekend PPS Picture per Second and recording quality for each channel The lt Preset Configuration gt must be set to lt OFF gt for accessing these schedules The menu is displayed as below in Record mode 720x240 60PPS in NTSC 720x288 50PPS in PAL www dynacolor com tw All rights reserved 79 User s Manual 5 4 4 1 5 4 4 2 5 4 4 3 5 4 4 4 5 4 4 5 80 DYNACOLOR Ke Per Camera Config Cameral Select CH1 Day Night Weekend Normal PPS 7 5 7 5 7 5 Normal Size 7KB 7KB 7KB Event Max PPS 30 30 30 Event Size 11KB 11KB 11KB Event Active Both Both Both Camera Select The item is used to select a desired channel for setting the parameters Move the cursor to lt Camera Select gt and press ENTER then select a channel using UP DOWN buttons Press ENTER again to confirm the setting Normal PPS Normal PPS Picture per Second is used to set the recording rate for normal status Please note that the total normal pps for all channels is limited under the maximum PPS for each Record mode To increase one channel s pps you may have to reduce other s first Event pps is not restricted to this rule since a smart event scheduler will handle to the total pps with a correct weighting Normal Size The item is used to set the picture size for normal status recording The available optio
49. al IP LAN IP The virtual IP would be 192 168 x 1 When the remote user wants to operate the DVR he will have to send command to the real IP i e the router the router has to map forward the command to the DVR Thus it is required to set up the router for port mapping forwarding before you can see image remotely from your DVR 192 168 0 167 DVR2 EVI 2 192 168 0 200 Internet E y Router PC WAN IP 218 160 54 13 Remote User LAN IP 192 168 0 1 PC 2 192 168 0 101 See your router manufacturer s websites for more instructions on port mapping Following is an example of how the router should be set www dynacolor com tw 151 All rights reserved DYNACOLOR Ke User s Manual Router PC DVR 1 DVR 2 D Link DI 724P IP 192 168 0 100 IP 192 168 0 167 IP 192 168 0 200 WAN IP 218 160 54 13 Trigger port 80 Trigger port 81 LAN IP 192 168 0 1 e To change the setting of the router you need a PC with web browser e Connect to D Link DI 724P from PC via IE The setup screen will show after entering the correct user name and password 4 D Link DI 724P Web Configuration Microsoft Internet Explorer DEAR File Edit View Favorites Tools Help ay Q gt EN a Le JO search Jp Favorites a d Ki Address http 192 169 0 1 E ge n L4 D Link AirPlus G High Speed 2 4GHz Wireless Router Advanced Tools Status Help DI 724P The DI 724P is an Ethernet Wirele
50. and software version From the System Setup menu select Version and press ENTER The following menu is displayed Version Hardware V1 0 Software XXXX XXXX XXXX XXXX Software Upgrade via Local Device Software Upgrade via Internet The items in this menu are described in the following subsections Hardware Version The item identifies the hardware version for this unit Software Version The item identifies the software version installed on this unit Software Upgrade via Local Device This item is used for updating the DynaGuard 200 series software by local device The menu is displayed as follows Software Upgrade via Local Device Upgrade Version Select XXXX XXXX XXXX XXXX NO Connect an USB drive contains upgrade software to the unit the available upgrade files will be listed in the menu To update the system select a file and use UP DOWN buttons to choose YES Press ENTER to confirm the selection and start the upgrade process The DynaGuard 200 series unit uploads the software updates the system files and reboots automatically The upgrade may take several minutes to save the changes in the memory of the system After reboot the unit please check the software version again www dynacolor com tw 51 All rights reserved User s Manual DYNACOLOR Ke AN NOTE No power interruption is allowed during the software update Ensure that no power interruption can occur until the unit
51. anged 52 www dynacolor com tw All rights reserved DYNACOLOR Ke 5 1 3 1 Date Time Setting Select Date or Time and press ENTER for adjusting the settings LEFT RIGHT buttons are used to move the cursor to previous or next field ENTER is for selecting and UP DOWN are used to change the value in the selected field 5 1 3 2 Date Time Display Users are allowed to choose to set the date time OSD displays in 1 or 2 rows Use the UP DOWN buttons to change the setting The default is to display the date time OSD in one row 5 1 3 3 Date Display Mode This function allows user to set the OSD display type of the date time There are three options to select from Y M D M D Y or D M Y Y represents Year M represents Month and D represents Day Use UP DOWN keys to change the setting The default setting is lt Y M D gt in both NTSC PAL formats 5 1 3 4 Time Display Mode User can choose to set the time format to 12 hour or 24 hour Use the UP DOWN buttons to change the format The default setting is 24 hour 5 1 3 5 Date Time Order The item is used to set the order of Date Time display to Date First or Time First Select this item and press ENTER then use UP DOWN buttons to change the setting 5 1 3 6 Daylight Saving Time The item is for people who live in certain regions to observe Daylight Saving Time Select ON to enable or OFF to disable the function w
52. arc WERE Phone Number to Dial Whatis your ISP s phone number Type the phone number below Phone number 1 You might need to include a 1 orthe area code or both If you are not sure you need the extra numbers dial the phone number on your telephone If you hear a modem sound the number dialed is correct e Enter the Username and Password that is set in the Dial in Setup menu r New Connection Wizard J Internet Account Information You will need an account name and password to sign in to your Intenet account Type an ISP account name and password then write down this information and store itin a safe place Ifyou have forgotten an existing account name or password contact your ISP User name Password Confirm password C Use this account name and password when anyone connects to the Internet from this computer Make this the default Internet connection Back Next gt J Cancel 102 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual e Click lt Finish gt to complete the dial in connection r New Connection Wizard Completing the New Connection A Wizard You have successfully completed the steps needed to create the following connection DVR Dial In Share with all users ofthis computer The connection will be saved in the Network Connections folder To create the conn
53. ble alarm input detection According to your application select lt N O gt Normal Open or lt N C gt Normal Close to enable the alarm input detection or select lt OFF gt to disable the detection The default setting is lt OFF gt If you set this item to lt N C gt but did not install any device to the unit the alarm will be triggered and the Event Icon displayed continually until this item is changed to lt N O gt OFF or install a device to the unit Alarm Out This item allows user to assign an alarm on certain channel to activate the relays These signals can be used to drive a light or siren to caution an alarm event Select from the options lt A Only gt indicates Alarm Out A B Only indicates Alarm Out B Both indicates Both Alarm Out and None indicates No Alarm Out The default setting is None Database Setup The menu displays information of internal and external disks In the Main menu move the cursor to Database Setup and press ENTER The following menu is displayed www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Database Setup 1 Total Size xxx GB 2 Free Size xxx GB 3 Rest Normal REC 3Days 7Hrs 4 Rest Event REC 15Hrs 5 Internal Disks 6 External Disks NOTE If the hard disk is failed detected the message HDD fail will display 5 7 1 Total Free Size of HDD The Total Size of HDD shows the total ca
54. ccount you won t need a phone number Use the CD I got from an ISP Back ex Cancel User s Manual e Select Connect using a dial up modem to connect to the internet through phone line and a modem Click Next to continue New Connection Wizard Internet Connection How do you wantto connectto the Internet h 8 Connect using a dial up modem This type of connection uses a modem and a regular or ISDN phone line Connect using a broadband connection that requires a user name and password This is a high speed connection using either a DSL or cable modem Your ISP may refer to this type of connection as PPPoE Connect using a broadband connection that is always on This is a high speed connection using either a cable modem DSL or LAN connection Itis always active and doesn t require you to sign in Back Next gt Cancel www dynacolor com tw All rights reserved 101 DYNACOLOR User s Manual 7 e Type the name of the connection you are creating r New Connection Wizard 7 Connection Name Whatis the name of the service that provides your Internet connection Type the name of your ISP in the following box ISP Name DVR Dial In The name you type here will be the name of the connection you are creating Back I Next gt J Cancel e Enter the phone number of the modem that is connected to the unit m
55. ce network Setup a home or small office network To continue click Next R 3 Next gt Cancel e Set up the network connection type Select Connect to the Internet and click Next to continue 100 www dynacolor com tw All rights reserved DYNACOLOR Ke r New Connection Wizard Network Connection Type What do you wantto do 8 Connect to the Internet Connectto the Internet so you can browse the Web and read email Connect to the network at my workplace Connectto a business network using dial up or VPN so you can work from home a field office or another location Set up a home or small office network Connectto an existing home or small office network or setup a new one Set up an advanced connection Connect directly to another computer using your serial parallel or infrared port or setup this computer so that other computers can connectto it Back S Next gt J Cancel e Select Set up my connection manually and click Next to continue r New Connection Wizard Getting Ready The wizard is preparing to set up your Internet connection How do you wantto connectto the Internet Choose from a list of Internet service providers ISPs 8 Set up my connection manually For a dial up connection you will need your account name password and a phone number for your ISP For a broadband a
56. configure the dome controls settings see the following sections Dome Connection Follow the steps to install dome camera e See section 2 4 Rear Panel Connections for RS 485 port pin definition e Refer to the following figure Connect the R R terminals on the dome camera to the D D terminals on the RS 485 port by RS 485 cable respectively Power RS 485 Cable www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual 4 6 2 Dome Protocol Setup The Dome Protocol item lists the available dome protocols for communicating with dome cameras connected to the DynaGuard 200 series From the Main menu select lt Camera Setup gt and press ENTER The following menu is displayed Camera Setup 1 Camera Select CH1 2 Dome Protocol None 3 Dome ID 0 4 Camera Title 5 Covert NO 6 Termination NO 7 Brightness 0 8 Contrast 0 9 Saturation 0 10 Hue 0 11 Audio Association Both To configure dome protocol select a camera first and set the communications protocol associated with dome camera using the Direction buttons and ENTER The available protocol includes lt DynaColor gt lt Pelco D gt lt Pelco P gt lt AD422 gt and lt None gt default NOTE The settings become effective after saving the changes and exiting from the menu 4 6 3 RS485 Setup DynaGuard 200 series control the domes via RS 485 communication protocol The RS 485 parameters in DynaGuard 200 series must b
57. count is currently accessing the unit OSD setup menu you are not allowed to save the configuration as an Admin on DynaRemote The DynaGuard unit administrator account has priority The items in Configuration menu are described in the table below www dynacolor com tw 129 All rights reserved User s Manual 5 1 130 DYNACOLOR Ke Item Description System Configures the system related items on the remote unit such as Setup password date time and network settings Monitor Configures monitor related items such as brightness and saturation Setup etc Camera Configures camera titles and other camera related items on the Setup remote unit Record Configures record related items on the remote unit such as event Setup and audio recording parameters Event Configures the way in which the remote unit handles events Setup Buttons in Configuration Screens The configuration screen contains several buttons that enable you to save and close the settings These buttons are shown as below x Cancel w Apply The functions of these buttons are described below e OK You can save just the settings in the section of the Configuration screen in which you are working click lt OK gt to save the settings and close the Configuration screen e Cancel Click to close the screen without saving any changes e Apply Click Apply to save all of the settings in the Configura
58. ction Configuration e Sensitivity The item is used to set the sensitivity of detection grids for the camera A greater value indicates more sensitive motion detection A motion alarm will be triggered once the amount of motion detected exceeds the Threshold value Click UP DOWN arrow buttons to adjust the value The value is indicated in 4 increment e Area Threshold lt Area Threshold gt means the motion alarm triggered level if the percentage of triggered grids to total detection area is greater than the set value the motion alarm will be triggered For example if 10 grids are selected and the lt Area Threshold gt value is 70 the motion alarm will be triggered when seven grids are motion detected Click UP DOWN arrow buttons to adjust the value The value is indicated in 4 increment Alarm In This item allows user to enable disable alarm input detection According to your application select lt N O gt Normal Open or lt N C gt Normal Close to enable the alarm input detection or select lt OFF gt to disable the detection The default setting is lt OFF gt If you set this item to lt N C gt but did not install any device to the unit the alarm will be triggered and the Event Icon displayed continually until this item is changed to lt N O gt OFF or install a device to the unit Alarm Out This item allows user to assign an alarm on certain channel to activate the relays These signals can be used to dr
59. d is required to export video The exported video will be named by the exporting date and time and classified by event type Each recorded video will be exported into four files if exported with digital signature including gpg avi drv sig and readme txt Make sure an external storage device is available and connected to the appropriate port for video export From the Main menu select lt Video Export gt and press ENTER The menu is displayed Video Export 1 Select Device 2 Select Ch CH1 CH2 CH3 CHA 3 From 2005 03 19 AM 07 50 05 4 To 2005 03 28 PM 03 09 18 5 Select Events 6 Data Type Normal 7 Export Format DRV www dynacolor com tw 41 All rights reserved User s Manual 4 5 1 4 5 2 42 DYNACOLOR Ke 8 Digital Signature NO 9 Erase Disc NO 10 Begin Export NO Select Device The available external devices for exporting video will be listed by name and free size in Select Device menu The Select Device menu displays as follows Select Device Device Name Available Sel XXX XXX X X XX 256 MB NO XX XXX XX XXXX 1 5 GB NO The DynaGuard 200 series only supports EXT3 file system If you connect an external HDD to the unit ensure the format of HDD is EXT3 Device Name The item shows the name of the available device Available The item shows the free space of the available device Select Set the item to YES to start the export or NO
60. dard 6 25 PAL 9 KB 25 PAL 13 KB Both Extended 7 5 NTSC 30 NTSC on 6 25 PAL oe 25 PAL TKB Both 0 NTSC 30 NTSC Event Only 0 PAL 25 PAL 13 KB Both 1 NTSC 1 NTSC 128Kbps DSL 1 PAL 2 KB 1 PAL 2 KB Both 4 NTSC 4 NTSC 256Kbps DSL 4 PAL 2 KB 4 PAL 2 KB Both 4 NTSC 4 NTSC 512Kbps DSL 4 PAL 3 KB 4 PAL 3 KB Both User User User User SE Selected Selected Selected Selected User selected AN NOTE If selecting this Record mode only the image from channel 1 4 will be recorded Record Mode Half D1 mode NTSC 720x240 60PPS PAL 720x288 50PPS Preset Normal Normal Event Event Event Active Configuration PPS Size PPS Size pes anally E Ga WEB e TKS haa en Standard orate 7 KB nus RE 14 KB Both ME COSE 3KB mum SE 14 KB Both Event Only con SPA 14 KB Both 128Kbps DSL i SES 2 KB n Am 2 KB Both 256Kbps DSL nim 2 KB pub nts 2 KB Both 512Kbps DSL nh 3KB ei RE 3KB Both 32 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual OFF User Selected User Selected User Selected User Selected User Selected Record Mode CIF mode NTSC 360x240 120PPS PAL 360x288 100PPS Preset Normal Normal Event Event Event Active Configuration PPS Size PPS Size SES 2S PAL is SPAD SAB iene Me Standard GE 5 KB OBP nt 9KB Both c4 abra se een gs Both Event Only rae GP RE 9 K
61. delete event video before a specific date Use LEFT RIGHT buttons to move the cursor to next or previous field ENTER to select the item and UP DOWN to adjust the value Purge Event Items Select the event video you want to delete and confirm the deletion by pressing UP DOWN and ENTER keys choose lt YES gt to start the deleting or choose lt NO gt to abort the process Start to Purge After selecting the video you want to delete or setting the date for deletion set this item to lt YES gt for start the deleting or choose lt NO gt to cancel 5 5 Sequence Setup The Sequence Setup menu allows setting the camera sequence schedule and dwell time for main and call monitor Select lt Sequence Setup gt in Main menu and press ENTER the menu displays as follows Sequence Setup 1 Main Monitor Dwell 5 Sec 2 Main Monitor Schedule 3 Call Monitor Dwell 5 Sec 4 Call Monitor Schedule Items in the Sequence Setup menu are described in the following subsections www dynacolor com tw 83 All rights reserved User s Manual 9 9 1 5 5 2 5 6 84 DYNACOLOR Ke Main Call Monitor Dwell The Main Call Monitor can be set to display full screen video of all installed cameras in sequence This item is used to set the Main Call Monitor dwell time which is the amount of time elapsed between switching images The dwell time is in the range of 1 to 120 seconds The default value is 5 seconds Main Call Monitor
62. e keyboard directly or use the pull down menu to select the desired date and time e DST Bias The item is used to set the amount of time to move forward from the standard time for daylight saving time Available options are lt 30 gt lt 60 gt lt 90 gt and lt 120 gt minutes When you complete the settings remember to take one of the following actions e Click lt OK gt to save the modified settings www dynacolor com tw All rights reserved DYNACOLOR Ke 5 1 3 5 1 4 5 1 5 User s Manual e Click lt Apply gt to save all modified settings set in the configuration menu e Click lt Cancel gt to abort and leave all settings unchanged Unit Name The item is used to change the unit name using the keyboard directly Password The Password menu allows administrator to change the password settings for accessing the unit Click lt Password gt in System Setup menu to display the screen Enable Password The item is used to determine if the password is required for accessing the OSD menu Select lt YES gt to demand entering password when accessing the OSD menu if not select lt NO gt Load Factory Password This item allows the administrator to reload the factory password in case that the administrator cannot remember or locate the password There are three options to select from lt Admin gt reload the Admin password only lt User gt reload the User password only and lt All gt reload the Admin
63. e remote viewing software DynaRemote Administrator Password User Password 1234 4321 It is strongly suggested to change the passwords to prevent unauthorized access to the unit After entering the correct password the Main menu is displayed Main Menu System Setup Monitor Setup Camera Setup Record Setup Sequence Setup Event Setup Database Setup Configuration Video Export 10 Shutdown OONDOaABRWDND www dynacolor com tw All rights reserved DYNACOLOR Ke 3 3 1 3 3 2 User s Manual Move the cursor up down over the OSD items using the Direction buttons and press ENTER to enter the selected sub menu Button Usage in OSD Menu Direction Buttons In the OSD menu Direction keys are used to move the cursor to previous or next fields UP DOWN are used to change the value in the selected field ENTER In OSD menu or selection interface press the button to make selection or save settings ESC Press to cancel or exit from certain OSD menu without saving any changes Button Usage in Virtual Keyboard A virtual keyboard shows when edit the settings such as camera title e mail address etc The virtual keyboard displays as follows Z oc O DW o a o DW gt WY o H y a Z Z X x 3 N Z 3 o Ki a 4 o e x lt N 4 gt Backspace Delete Cancel OK To input characters Move the cursor by pre
64. e set to the same parameters as the protocol for RS 422 setup of the dome Users are allowed to change the RS 485 settings of the DynaGuard 200 series Select System Setup in Main menu then select lt RS485 Setup from the System Setup menu and press ENTER The following menu is displayed RS485 Setup 1 Unit ID 224 2 Baud Rate 9600 3 Bits 8 4 Stop 1 5 Parity None www dynacolor com tw 45 All rights reserved User s Manual 4 6 4 46 DYNACOLOR Ke The ID number must match the ID address set by the dome The Unit ID is in the range of 1 to 255 The default ID is 224 Note that no two devices on the same bus should be given the same ID address or a conflict may occur The default DynaGuard 200 series RS 485 settings are 9600 Baud 8 Data Bits 1 Stop Bit and No Parity NOTE The settings become effective after saving the changes and exiting from the menu Dome Controlling Button The function buttons used in Dome Control are described as follows Set Go Toggle Hint Iris Focus Zoom Preset screen Open Near in ESC Enter Auto t Iis Focus Zoom Pan Tilt Close Far Out Set Go Preset This button is used to enter the Dome Preset menu to set up certain position as a preset and go to the predetermined preset positions for viewing Toggle Hint Screen This function is used to avoid viewing the dome parameter information while controlling dome camera Press this button to hide the screen Press it again to r
65. e to an alarm If set to lt OFF gt the buzzer is not activated The default setting is lt ON gt Event Icon The item enables ON disables OFF the display of Event Icon on the main monitor when an alarm event occurs The default setting is lt ON gt enable The event types are represented by a character respectively the descriptions are as below table Event type Description A Alarm in event M Motion detection event L Video loss event Email Notice The item enables ON disables OFF the Email notification of an event When an alarm event is triggered and lt Email Notice gt is enabled an e mail concerning the alarm event will be dispatched The default setting is lt OFF gt NOTE In order to send an event notification e mail successfully ensure that the unit connects to the internet Event Duration This item determines the duration of the buzzer and Alarm Out relay function after an alarm is triggered The available event duration range is from 1 second to 100 seconds The default setting is 5 seconds www dynacolor com tw 85 All rights reserved DYNACOLOR Ke User s Manual 5 6 5 Per Channel Config This menu is used to set the Video Loss Detect Motion Detect and Alarm In Out function for each channel The menu is displayed as below Per Channel Config 1 Channel Select CH1 2 Video Loss Detect ON 3 Motion Detect ON 4 Detection Config 5 Alarm In OFF
66. ection and close this wizard click Finish lt Back Finish J Cancel e Now the dial in connection is established 73 V Network Connections mx Fie Edi View Favorites Toos Advanced Hep La Qax BD P search 7 Fodes fv Address Network Connections R SUE Broadband gu EST S Create a new connection SL ded nectar Peu Q Setup a home or sma WAN Mi office netv chan Dial up settings lt HA CF Connection i A A Yahoo Connection E A DVR Dia In Li iDsconnected Firewaled H AT Disconnected Firewaled Disconnected Firewaled See Also CR ant D480 M 92 Modem C E Conexant D480 MDC V 92 Modem CK Y D480 MDC V 92 Mod j Network Troubleshooter Incoming Other Places Incoming Connections o ente connscid D Control Panel Si my Network Places h wy Documents LAN or High Speed Internet H My Computer wrt Local Area Connection 3 g2 1394 Connection 7 er Local Area Connection 4 gt Disal Fi al gt Ds Fire led gt C t F Tele Broadcom 440x Integrated ein 1394 Net Adap Cah E660 PCMCIA LAN adapte Details Network Connections System Folder Establishing Dial out Connection The Dial out function enables user to establish dial up modem communication to and from DynaGuard 200 series unit for remote notification use Follow the description to set up your DVR and PC DVR Configuration e Connect an USB modem to the USB socket and connect a working phone line to the mod
67. ed Alarm LED Red The LED should be lit during an alarm is triggered REC LED Green The LED should blink while the DynaGuard 200 series is recording HDD LED Yellow The LED should be lit while the HDD is processing data 3 1 2 Function Buttons The DynaGuard 200 series functional buttons on the front panel for normal operation are described as follows Channels Dome Mode SEQ Menu Esc Enter Zoom 1 E f i disc Recordable Call Play Freeze Search Direction Stop Buttons CHANNEL e When in both Live and Playback mode press the CHANNEL button to view the corresponding video in full screen The number of the CHANNEL buttons corresponds to the number of cameras supported by the unit www dynacolor com tw 23 All rights reserved User s Manual 24 DYNACOLOR Ke e When in dome control mode the first button is used to access the Set Go preset menu the second button is used to hide or display the dome setting parameters DOME Press the key to enter dome control mode MODE Press repeatedly to select for wanted main monitor display format There are three available view modes full screen 4 window 2x2 and 9 window 3x3 SEQ Sequence Press to start automatic sequencing of the video coming from the installed cameras MENU Press the button to call the OSD setup menu CALL Press to enter call monitor control mode PLAY STOP Press this button to switch between live image and
68. edisplay the screen www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Iris Open Use to open the Iris on the dome camera Focus Far Use to focus the selected dome camera far Zoom Out Use to zoom the dome camera out This function is for user to choose the viewing area more or less of it ESC Use to leave dome control mode and return to live and full screen viewing mode Auto Enter e n OSD Menu mode the key is used to make selection e n dome control mode this key is used to activate automatic focus and iris function Iris Close Use to close the Iris on the dome camera Focus Near Use to focus the dome camera near Zoom In Use to zoom the dome camera in This function is for user to choose the viewing area more or less of it Pan Tilt Use to pan and tilt dome camera 4 6 5 Setting Preset Points The DynaGuard 200 series unit allows user to set preset positions the amount of preset points depends on the dome manufacturer Follow the steps to set preset points e Press a Channel key to view the corresponding camera in full screen e Then press DOME to enter dome control mode www dynacolor com tw 47 All rights reserved DYNACOLOR Ke User s Manual e Use Direction buttons to position the dome camera to desired position e Press 2 to view the dome control Hint Screen press 2 again to toggle the Hint Screen Hint Screen DOME ESC Exit MODE PLAY Iris Open
69. educe other s first Event pps is not restricted to this rule since a smart event scheduler will handle to the total pps with a correct weighting Normal Size The item is used to set the picture size for normal status recording The available options are 3 5 7 9 and 11 KB Event Max PPS Event Max PPS is used to set the event recording rate for Event status Normally the Event PPS is set to equal or greater than Normal PPS the setting is depending on your application If the Event PPS is set to 0 DynaGuard 200 series unit stops recording event video during alarms Event Size The item is used to set the picture size for event status recording The available options are 3 5 7 9 and 11 KB Event Active Users are allowed to choose which alarm type needs to be recorded The available options are Alarm alarm events Motion motion www dynacolor com tw All rights reserved DYNACOLOR Ke 5 4 4 5 4 5 5 4 6 5 4 7 User s Manual detection events Both alarm event motion detection and None no events active The default setting is Both which includes Alarm and Motion event recording Event Percentage The item is used to set the event recording percentage of total capacity The unit stops recording event video when the event space is full Set the event data percentage by clicking the UP and DOWN arrows in the box Data Lifetime Data L
70. elected camera displayed on the monitor Contrast The item is for adjusting the image s contrast displayed on the monitor of the selected camera Saturation The item is for adjusting the image s saturation displayed on the monitor of the selected camera Hue The item is for adjusting the image s hue displayed on the monitor of the selected camera Audio Association The item is used to establish the connection between the selected camera and the two audio in channels Select lt Both gt lt Left Only gt lt Right Only gt or None to set up the connection Record Setup The Record Setup menu allows user to set record related items such as recording schedule pre set configuration pre alarm recording time or circular linear recording etc Click lt MENU gt button on the main window toolbar and click the plus icon to expand Record Setup menu www dynacolor com tw All rights reserved DYNACOLOR 4 User s Manual System Setup Monitor Setup Camera Setup Schedule Setup Preset Contig Per Camera Config Event Percentage Data Lifetime Pre Alarm Recording Circular Recording Audio Recording Event Setup 5 4 1 Schedule Setup This submenu is used to set the day and night time or weekend recording schedule The Night and Day schedules are used to define daytime and nighttime the Weekend schedule is tailored for weekends and holidays Configuration System Setup
71. eletion of a record Only those video recorded during Data Lifetime will be displayed on the screen and can be played back those video recorded outside the duration time will be deleted Press ENTER to select this item in Record Setup menu and then use UP DOWN buttons to set the data lifetime The value ranges from lt 1 gt to lt 365 gt days or select 0 to disable the function Pre Alarm Recording This item is used to set the duration of pre alarm recording video The pre alarm recording function aims to make user viewing a more complete event video what user can view is not only the video recorded after the alarm is triggered but also the video recorded ahead the alarm When an event is triggered while normal recording is in effect the unit will start copying the pre alarm and the post alarm video to the event video The pre alarm duration can be set from 0 30 seconds The default setting is 15 seconds www dynacolor com tw 81 All rights reserved User s Manual 5 4 8 5 4 9 5 4 10 5 4 10 1 82 DYNACOLOR Ke The quality of the pre alarm video is the same as the quality setting for normal record video and the quality of the post alarm video is the same as the quality setting for event record video Circular Recording User can choose to record video in circular mode or in linear mode If you choose to record in circular mode then the unit begins to overwrite the oldest previously recorded video and sto
72. em e Press MENU and input the Administrator password to access the OSD Main menu Select Network Setup and then Dial out Setup to set up the Dial out settings www dynacolor com tw 103 All rights reserved DYNACOLOR Ke User s Manual e Select the lt Email Address gt in Network Setup menu to edit an e mail address for alarm notification e Select lt Event Setup gt in Main menu and set the Email Notice function to lt ON gt enabled e Exit the OSD menu and save the configuration e For more information on dial out settings see section 5 1 6 4 Dial out Setup PC Configuration e Click lt Start gt lt My Network Places gt lt View Network Connections gt and then select lt Create New Connection gt The New Connection Wizard is displayed Click lt Next gt to continue New Connection Wizard Welcome to the New Connection A Wizard This wizard helps you Connectto the Internet Connectto a private network such as your workplace network Setup a home or small office network To continue click Next R ack Next gt Cancel e Setup the network connection type Select Set up an advanced connection and then lt Accept incoming connections gt Click lt Next gt to continue r New Connection Wizard Advanced Connection Options Which type of connection do you wantto setup Select the connection type you want Accept incoming connections Al
73. em connection To configure the item DHCP must be set to OFF Move the cursor over Dial out Netmask gt and press ENTER and then press UP DOWN buttons to change the values in the selected field Dial out Gateway Users are allowed to specify the IP address of the gateway or router associated with this unit To configure this item DHCP must be set to OFF Move the cursor over Dial out Gateway and press ENTER and then press UP DOWN buttons to change the values in the selected field Dial out DNS The item allows user to specify the IP address of the Domain Name System DNS associated with the unit To configure this item DHCP must be set to OFF Move the cursor over Dial out DNS gt and press ENTER and then press UP DOWN buttons to change the values in the selected field Phone Number The item is used to set the dial out phone number Follow these steps to setup the phone number e Select Phone Number from Dial out Setup menu and press ENTER A virtual keyboard displays e Use Direction buttons to move the cursor for selecting number e Press ENTER to add the selected number to the password entry field e When done press ENTER to save the settings and exit www dynacolor com tw 63 All rights reserved User s Manual 64 DYNACOLOR Ke Dial out Account This item enables user to set the Dial out user name which is used for dialing out to ISP server See your network service
74. erate over Internet port 25 Click the UP and DOWN arrows in the box to adjust the value SMTP Account The item allows user to setup the SMTP username SMTP Password The item allows user to setup the SMTP password DDNS Setup Click lt DDNS Setup gt to display the DDNS Setup menu It allows user to www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual configure the DDNS related settings Configuration System Setup Language Enable DDNS Date Time Unit Name Password DDNS Port Network Setup lj Email Address Submit Update Host Name SMTP Setup R5485 Setup Audio Output Key Beep Monitor Setup Camera Setup Record Setup Event Setup X Cancel PO Apply e Enable DDNS The item is used to enable or disable the Dynamic Domain Name Service Select lt YES gt to enable the service or lt NO gt to disable e Host Name The item allows user to setup a domain name which is used when entering the DynaGuard 200 series unit through the internet on your remote PC e DDNS Port The item allows user to setup the port for DDNS Click the UP and DOWN arrows in the box to adjust the value e Submit Update When done select lt YES gt to update the settings NOTE If there are two DynaGuard 200 series units set the same domain name the later setting will not be submit successfully 5 1 6 RS485 Setup This menu allows setting up the parameters of the unit s RS 485 co
75. ering the specific date and time of the wanted video the unit will then search for the matched video and play it on the monitor Alternatively user can search event video by selecting channel as well www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual In live or playback mode press SEARCH to enter the Search menu which is shown as follows Search Search By Time From 2005 01 01 00 00 00 End 2005 05 01 00 00 00 Start Time 2005 01 01 00 00 00 Begin Playback Select Channel CH1 CH2 CH3 CH4 Event List Search by Time Follow the steps to search video by date and time e Press SEARCH button to enter the Search menu the From Time and End Time of the available video is listed on top of the screen The value is unchangeable e Use Direction buttons to move the cursor for setting the Start Time adjusting the date and time values by UP DOWN keys e Press ENTER to confirm the settings or ESC to abort e Move the cursor to lt Begin Playback gt and press ENTER to start playing back the selected video e Either press PLAY STOP again or ESC to return to live video AN NOTE If there is no available recorded video that matches your specified time and date the unit starts playback from the next available video AN NOTE The date time information will be shown on the screen with a DST icon if the Daylight Saving Time function is enabled S indicates summer time and
76. ernet Protocol The default wide area network protocol that provides communication across diverse interconnected networks lt Back Next gt Cancel e In TCP IP address assignment if the PC has DHCP server then choose Assign TCP IP addresses automatically using DHCP gt else choose Specify TCP IP addresses and enter the range of IP addresses that you wish to use Once done click lt OK gt to confirm and back to Networking Software menu Click on Next to continue 106 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Incoming TCP IP Properties Network access Allow callers to access my local area network TCP IP address assignment Q Assign TCP IP addresses automatically using DHCP 8 Specify TCP IP addresses Font 19 18 0 1 Ta 193 1458 OS Total 3 Allow calling computer to specify its own IP address e Click Finish to complete the process r New Connection Wizard Completing the New Connection Wizard You have successfully completed the steps needed to create the following connection Incoming Connections R The connection will be saved in the Network Connections folder To create the connection and close this wizard click Finish lt Back Finish Cancel e The Incoming connection is established W Network Connections ey E Fie Edt View Favorites T
77. etup gt lt Network Setup gt then lt LAN PPPoE Setup gt to check the IP e Start the IE you may start it either by clicking on the desktop icon or by using the Start menu to access it e Select Tools from the main menu of the browser then lt Internet Options gt and then click the lt Security gt tab e Select lt Trusted sites gt and click lt Sites gt to specify its security setting www dynacolor com tw All rights reserved 113 DYNACOLOR Ke User s Manual Internet Options General Security Privacy Content Connections Programs Advanced Select a Web content zone to specify its security settings o 9 Oo e Internet Local intranet BRECH Restricted sites Trusted sites This zone contains Web sites that you trust not to damage your computer or data Security level for this zone Custom Custom settings To change the settings click Custom Level To use the recommended settings click Default Level SEET e Disable Require server verification https for all sites in this zone Type the IP address of the unit in field and click lt Add gt to add this web site to the zone Trusted sites You can add and remove Web sites from this zone All Web sites in this zone will use the zone s security settings Add this Web site to the zone Web sites erg 168 8 167 http 11192 168 8 174 C Require server verification https
78. f the gateway or router associated with this unit To configure this item DHCP must be set to lt OFF gt DNS The item allows user to specify the IP address of the Domain Name System associated with the unit To configure this item DHCP must be set to lt OFF gt If the network server is unavailable when using DHCP the unit searches for the network server and boots up more slowly This network search continues until it times out PPPoE Account The item allows user to setup the PPPoE login username To setup the login username follow the steps e Select lt PPPoE Account gt from LAN PPPoE Setup menu and press ENTER A virtual keyboard displays PPPoE Account A BCD F GH iI J M O QRS TUVWX Y Z abcde fgh ij m n o q r s u v w X yz 012 34 56 7 8 Wo uu Backspace Delete Cancel OK e Use Direction buttons to move the cursor to the wanted character e Press ENTER to add the character to the username entry field e When done move the cursor to lt OK gt and press ENTER to save the settings and exit NOTE For accessing the PPPoE settings select lt PPPoE gt as the Network Type in Network Setup menu www dynacolor com tw All rights reserved DYNACOLOR Ke 5 1 6 3 User s Manual PPPoE Password The item allows user to setup the PPPoE password Follow these steps to setup the login password e Select lt PPPoE Password gt from LAN PPPoE Setup menu and press ENTER A virtual keyboard dis
79. f the start time of Day and Night Time using Direction buttons e Press ENTER to confirm the settings or ESC to cancel e f you want to have a weekend record choose YES to enable the Weekend Schedule in advance and then set the Weekend Start End time e Press ESC to back to previous page Preset Record Configuration The Preset Config is used to select the preset recording quality and frame rate Different default recording quality levels are offered for user to choose Best Quality Standard Extended Record Event Only 128Kbps DSL 256Kbps DSL 512Kbps DSL and OFF According to various Record modes the preset configuration options for normal and event status are described in terms of relative recording rate PPS and recording size for each channel in the table below The preset conditions Best Quality Standard Extended Record Event Only 128Kbps DSL 256Kbps DSL and 512Kbps DSL override any other quality and rate settings The default Preset Configuration setting is Standard www dynacolor com tw 31 All rights reserved DYNACOLOR Ke User s Manual Record Mode Full D1 mode NTSC 720x480 30PPS PAL 720x576 25PPS Preset Normal Normal Event Event Event Active Configuration PPS Size PPS Size 7 5 NTSC 30 NTSC Both Best Quality S ABRAL 19B 25 PAL 13KB Alarm Motion 7 5 NTSC 30 NTSC Stan
80. ght Saving Time OFF Event Setup DST Start nno a zl 1st v Sun D DST End 0200 4 Oct z Last v Sun z DST Bias fo a X Cancel www dynacolor com tw 131 All rights reserved User s Manual 132 DYNACOLOR Ke Date amp Time These items are used to set the date and time for the remote unit Enter the date and time information into the fields using the keyboard directly or use the pull down list next to the Date and Time fields to select the desired date and time with the displayed calendar Date Time Display User can set the date and time information to display in one or two rows The default is lt 1 Row gt Date Display Mode Users are allowed to set the display mode for the remote unit from the pull down menu The date is comprised of Year Y Month M and Day D The default display mode is lt Y M D gt in NTSC and PAL format Time Display Mode You can set the remote unit s time format in 12 hour or 24 hour The default setting is lt 24 HR gt Date Time Order The item is used to set the order of Date Time display to lt Date First gt or lt Time First gt Daylight Saving Time The item is for those people who live in certain regions to observe Daylight Saving Time Select lt ON gt to enable or lt OFF gt to disable the function e DST Start End Time The items are used to set the daylight saving duration Enter the date and time information into the fields using th
81. grades When a new version of DynaRemote software is available on your DynaGuard 200 series unit it will be automatically installed when you access the unit Follow the steps to upgrade the software www dynacolor com tw 117 All rights reserved DYNACOLOR Ke User s Manual Confirm 9 An Incompatible version of VideoViewer ocx was detected on your PC Ze Would you like to download the correct version for proper operations Notice You must have Windows Administrator privilege to update successfully Please start your browser again after it closed e The message Browser will be closed is now displayed Click lt Yes gt to accept to version upgrade e Start your IE again and enter the IP address of the remote DynaGuard 200 series unit in the Address field of the browser or if you have set a Favorite for the unit address click the Favorites entry for your unit e When the software is completely downloaded the Login Screen will be displayed 118 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual 4 Basic Operation When you successfully connect to a unit the DynaRemote main window displays as follows The connected cameras of the remote unit will be listed on the left and an array of camera output windows displayed on the right of the main window To view the main window in full screen view press lt F11 gt on your keyboard Viewing Viewing Entering Live Playback Configurat
82. h Dome Control DYNACOLOR Ke www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual 4 2 Instant TIN E 122 4 2 1 Recording Video US I E 122 4 2 2 To Playback Instant Recording Video reete oce rete tores 122 A3 TO Fy 0 10 co 123 43 1 Playing Back Remote Ua ttt ete a tire eee cecal 123 4 3 2 WO lee Local Uh ccc cco ord root ere ectuccteedeveceuedisese 124 4 3 3 To Playback Local avi Pil Gress cccccscesssecccecsisassesnseareesneeaseessjeesnssuecsetes 125 JaA Playpack ur 126 44 Verifying Digital SIQNAtUIe cccccecncccececncecncecncecesncmeecnseansecesnamenamseamcncesnamenenencns 126 5 Configuring the Remote Unit eciscdciciiseicisecsadciuacsadcineinndeiacsnicdinicadiiuacandeiencanieieisaciows 129 Configuration BOUE adesso eis cedududu ts cudude cu dodusu tto tude uta io deu edt 129 Buttons in Configuration SOPBOTIS ura ba Resa x ER egGgeEeg 130 SMS 000 E 130 E P WM Ee 131 914 2 Dater TIME E 131 Date S dE 132 Date Time DIS DAY C 132 Dee 132 Tim Display M d EHE 132 D te Min 132 Daylight Saving PIME E 132 Sko Unt un 133 ye e a Ss E 133 Enable OIG D 133 Load Factory Password EE 133 SLS E EE 133 GE ME 134 SMI P eee E 134 DDNS Setup een eee en Re Or ne ee ree ea eee nor eee 55 0 9 2 9 80 22 134 ET 135 SL Audo UN P E 137 Sko tee 137 5 2 Monitor Set p E 137 Show Camera WD Mee T 138 Monitor le Tu
83. he lt Start gt field You can change the date and time either by typing desired numbers directly or using the arrow buttons To type directly Click on day month and year of date field respectively and type the desired numbers directly Follow above steps to adjust the hour minute and second of time field To use the arrow buttons Click on the arrow button next to the date field to display the calendar then click the left and right arrow at the top of the calendar to change the date Use up and down arrow in the right side of the time field to change to the wanted time To click lt Near From gt Click lt Near From gt button to set the date and time as the lt From gt time To click lt Near To gt Click lt Near To gt to set the date and time to five minutes ahead the lt To gt time e Select the camera s you want to play back Click lt Clear gt to clear all of the camera entry selections and click lt All gt to select all of the camera entries e Click OK to start the operation or click Close to abort 4 3 2 To Playback Local drv Files The lt Local Playback gt tab allows you to play back drv video files that stored on your PC s hard drive Click the lt Local Playback gt tab in the lt Playback gt screen for displaying downloaded video The Local Playback screen is shown as below 124 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Playback Filename Fol
84. he item to disable the audio output function Key Beep The item is used to enable or disable the key tone Select lt YES gt to enable the key tone or lt NO gt to disable Monitor Setup The Monitor Setup menu allows user to tune the quality of the displayed image Select lt Monitor Setup gt from the Main menu and press ENTER The www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual following menu is displayed Monitor Setup 1 Show Camera Title YES 2 Monitor Brightness 0 3 Monitor Contrast 0 4 Monitor Chrominance 0 5 Screen Center Adjust 6 Show Color Bar 7 VGA Resolution 800x600 The following sections describe the items found in the Monitor Setup menu 5 2 1 Show Camera Title This item allows user to choose whether to display the camera title on the screen or not The default is lt YES gt which displays the camera titles with the video from each camera 5 2 2 Monitor Brightness The function allows user to adjust the brightness darkness of image displayed on the monitor Move the cursor to the item then press ENTER and use UP DOWN buttons to adjust the numeric value The range of brightness values is lt 128 gt to lt 127 gt The default setting is lt 0 gt 5 2 3 Monitor Contrast The item is used to adjust the color contrast of image The range of contrast values is lt 128 gt to lt 127 gt the default setting is 0 5 2 4 Monitor Chrominance Move the curs
85. ice into database lt Remove gt remove the selected device from database lt Repair gt repair the damaged database of the selected device lt Format gt format the selected device NOTE Before removing external devices from the unit remember to remove the device from database Configuration The Configuration menu can be used to restore the default factory settings import and export configuration Select lt Configuration gt from the Main menu and press ENTER The following menu is displayed Configuration 1 Load Factory Default NO 2 Import Config 3 Export Config Items in this menu are described in the following subsections Load Factory Default This item is used to load the factory setting select lt YES gt to recall the factory default setup configuration from the read only memory or lt NO gt to cancel Import Configuration This item allows user to load a unit configuration that was saved in an external drive To import a configuration that was previously exported make sure the device that saved the configuration is connected to the unit Select lt Import Config gt from the Configuration menu and press ENTER The following menu is displayed www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Import Config Config Name Select XXXX XXXX NO XXX XX NO Press UP DOWN to select one of the listed available configuration files and choose YES to s
86. ick repeatedly to select the rewind speed 1x 2x 4x 8x 16x or 32x Play Pause Click once to play the recorded video click again to pause the playback Fast Playback Click to play the recorded video forward Click repeatedly to select the playback speed 1x 2x 4x 8x 16x or 32x Stop Stop playing the recorded video Verifying Digital Signature The digital signature aims to authenticate a video file exported from the unit Follow the description to verify the digital signature e Click Play on the main window tool bar e Click Verify tab to display the Verify window www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Playback Remote Playback f Local Playback Verity OK Filename gpg m ET Filename sig Status Log e Click lt Browse gt to select the gpg avi sig files respectively which belong to the exported video you want to authenticate Look in B 135607 DN e ek FE m NORMAL f 89641062 gp9 My Recent Documents Desktop My Documents My Computer My Network File name e9641 062 gpg v Places Files of type GPG files e Cancel e Click lt Verify gt to start verifying digital signature www dynacolor com tw 127 All rights reserved User s Manual DYNACOLOR Ke Playback Remote Playback Local Playback Filename gpg N 20050602V135507 189641062 gpg N 2DD50502 135807 NORM
87. ifetime indicates the time that a recording is saved and remained in the HDD between the creation and deletion of a record Only those video recorded during Data Lifetime will be displayed on the screen and can be played back those video recorded outside the duration time will be deleted Set the data lifetime by clicking the UP and DOWN arrows in the box The value ranges from 1 to 365 days or select 0 to disable the function Pre Alarm Recording This item is used to set the duration of pre alarm recording video The pre alarm recording function aims to make user viewing a more complete event video what user can view is not only the video recorded after the alarm is triggered but also the video recorded ahead the alarm When an event is triggered while normal recording is in effect the unit will start copying the pre alarm and the post alarm video to the event video The pre alarm duration can be set from 0 30 seconds The default setting is 15 seconds The quality of the pre alarm video is the same as the quality setting for normal record video and the quality of the post alarm video is the same as the quality setting for event record video Circular Recording User can choose to record video in circular mode or in linear mode If you choose to record in circular mode then the unit begins to overwrite the oldest www dynacolor com tw 145 All rights reserved User s Manual 5 4 8 5 5 9 9 1 5 5 2 146
88. ights reserved User s Manual DYNACOLOR Ke Two internal hard drives support up to 1TB capacity 16 External storage device for external CD RW DVD dual portable HDD or disk array 2X Digital Zoom available in both live and playback mode Export video AVI with audio and digital Signature Exported AVI file can be played in any PC with DIVX decoder installed Automatic camera detection Plug amp Play Covert camera operation provides enhanced security and administrator control Each camera configuration programmable for camera settings frame rate picture bit rate alarms motion detection Programmable day night weekend scheduling Programmable main monitor call monitor switching sequence Powerful alarm processor allows flexible alarm trigger and responses including alarm motion and camera failure Dome control protocols DynaColor Pelco D Pelco P and AD422 Supports multiple language on screen menus Two levels of password security Universal power input no external power unit www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual 1 2 Product Application Diagram Connect the unit with other devices as shown in the system diagram to complete a video surveillance solution The figure shows also the expandability and flexibility of this digital recording system System Configuration Remote Monitor Control Local Monitor Control Internet VGA Monitor Main Monitor Call Moni
89. ime OFF Dial in Service If the DynaGuard 200 series unit does not connect to the Ethernet user can communicate to the unit from remote PC through a modem as well Select ON to enable the Dial in function or OFF to disable Dial in Account This item enables user to protect the unit by establishing or changing a dial in user name for modem connection To setup the Dial in Account follow the steps e Select Dial in Account from Dial in Setup menu and press ENTER A virtual keyboard displays Dial in Account A B CD F G LJ M O QRS TUVWX Y Z a C e f g h i j k I m n o q rs t u vw Xx y z 0 1 3 4 5 6 7 8 9 lt Backspace Delete Cancel OK e Use Direction buttons to move the cursor to the wanted character e Press ENTER to add the selected character to the username entry field e When done move the cursor to OK and press ENTER to save the settings and exit 60 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Dial in Password The item allows user to setup the Dial in password Follow these steps to setup the login password e Select lt Dial in password gt from Dial in Setup menu and press ENTER A virtual keyboard displays e Use Direction buttons to select character e Press ENTER to add the selected character to the password entry field e When done move the cursor to lt OK gt and press ENTER to save the settings and exit Server IP
90. ion Click to Enlarge Bandwidth Camera Video Menu the View Area Selection Instant Recording Audio On Off Selecting Camera Selecting Display Mode The features on DynaRemote main window will be described in the following sections 4 1 To View Live Video You can view live video from the cameras attached to the remote unit by clicking Live button on the main window toolbar You can select desired display mode and assign wanted camera view to the window s after the view on the DynaGuard series unit is displayed on the main window To select wanted display mode and assign camera refer to the following sections www dynacolor com tw 119 All rights reserved DYNACOLOR Ke User s Manual 4 1 1 Selecting Display Mode You can indicate the number of windows displayed on the m main window Click one of the display buttons on the E WM FH BS left bottom corner of the main window You can select from 4 and 9 camera displays To view certain window in full screen you may either double click on the wanted window or click on the corresponding CAMERA button 4 1 2 Assigning Camera to Windows To assign a camera to a specific window in a multi window display mode follow the steps e Select the desired display mode first by pressing the corresponding MODE button e Click on the corresponding CAMERA number and drag the cursor onto the wanted display cameo The assignment you make will not be saved when you exit DynaRem
91. is completely rebooted NOTE Do not remove the external USB Thumb drive CD ROM before A the unit has completely shut down hard drive and fan are off Removing the external USB Thumb drive CD ROM before shut down can cause the system to update improperly 5 1 1 4 Software Upgrade via Internet The item is used to upgrade the unit s software via the internet Select one of the listed software version and choose YES The DynaGuard 200 series uploads the software updates the system files and reboots automatically 5 1 2 Language The Language item allows user to select the language for the OSD menu and screen messages Language selection takes effect immediately when the selection is done Press UP DOWN to select from listed languages and press ENTER to confirm 5 1 3 Date Time User can set the current date time and other OSD parameters in this menu The Administrator s privileges are required for entering the submenu In System Setup menu select lt Date Time gt and press ENTER the Date Time menu displays as follows Date Time 1 Date 2005 02 21 2 Time 10 39 26 3 Date Time Display 1 Row 4 Date Display Mode Y M D 5 Time Display Mode 24 HR 6 Date Time Order Date First 7 Daylight Saving Time ON 8 DST Start Apr 1 st Sun 02 00 9 DST End Apr Last Sun 02 00 10 DST Bias 60 Min NOTE The reset date time setting applies to record new video the date and time of previously recorded video will not be ch
92. ive a light or siren to caution an alarm event 148 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Select from the options A Only indicates Alarm Out A B Only indicates Alarm Out B Both indicates Both Alarm Out and None indicates No Alarm Out The default setting is None www dynacolor com tw 149 All rights reserved DYNACOLOR Ke User s Manual 6 Trouble Shooting Guide What if the server ask for ocx renewal all the time when you trying to connect to the remote software If the following screen displays repeatedly please follow the steps to delete the temporary internet files Notice The VideoViewer ocx need to upgrade Browser will be closed e Select Tools from the main menu of the web browser then Internet Options and then click the General tab Internet Options Home page lA You can change which page to use for your home page Address about blank Use Default Use Blank Temporary Internet files Pages you view on the Internet are stored in a special folder for quick viewing later Delete Cookies Delete Files Settings History The History folder contains links to pages you ve visited for quick access to recently viewed pages Days to keep pages in history 20 s Clear History Colors Fonts Languages Accessibility e Click the lt Delete Files gt button in the
93. ld SMTP Username The item allows user to setup the SMTP username Follow these steps to setup the login password e Select lt SMTP Username gt from SMTP Setup menu and press ENTER A virtual keyboard displays e Use Direction buttons to move the cursor for selecting character e Press ENTER to add the selected character to the password entry field e When done move the cursor to lt OK gt and press ENTER to save the settings and exit SMTP Password The item allows user to setup the SMTP password Follow these steps to setup the password e Select lt SMTP password gt from SMTP Setup menu and press ENTER A virtual keyboard displays e Use Direction buttons to move the cursor for selecting character e Press ENTER to add the selected character to the password entry field e When done move the cursor to lt OK gt and press ENTER to save the settings and exit www dynacolor com tw 67 All rights reserved User s Manual 5 1 6 8 68 DYNACOLOR Ke DDNS Setup Dynamic Domain Name System DDNS allows a DNS name to be constantly synchronized with a dynamic IP address In other words it allows those using a dynamic IP address to be registered centrally so others can connect to it by name Select lt DDNS Setup gt from Network Setup and press ENTER The menu displays as below figure DDNS Setup 1 Enable DDNS NO 2 Host Name 3 DDNS Port 81 4 Submit Update NO Enable DDNS The item is used
94. lor com tw All rights reserved DYNACOLOR Ke User s Manual Button Usage in Playback The button usage is slightly changed in playback mode Following is the button usage found in playback mode LEFT Reverse Playback The button is used to reverse the recorded video while the unit is playing back Press the button repeatedly to increase the speed of reverse playback by 1x 2x 4x 8x 16x or 32x RIGHT Forward Playback The button is used to play the recorded video fast forward Press the button repeatedly to increase the speed of forward playback by 1x 2x 4x 8x 16x or 32x FREEZE Press FREEZE to pause the playback video When the recorded video is paused press LEFT RIGHT to resume playback video single step reverse forward respectively Press FREEZE again to continue playing video ESC Press to exit current mode or stop playing back video and back to live mode Pause Playback and Single Step Forward To pause and resume recorded video follow these steps e Press one of the CHANNEL keys to display the corresponding camera in full screen e Press FREEZE to pause the current playback image e Press RIGHT LEFT Direction buttons to move the video single step reverse forward Press and hold RIGHT LEFT buttons to reverse forward the video single step continuously e Press FREEZE again to resume the playback operation Viewing Live Image in Playback Mode Press the MODE button repeatedly in playback m
95. low below steps to play back a downloaded drv file with DynaRemote e Click lt Open gt and the file selection screen is displayed e Select the drv video file to play back and click lt OK gt e Click lt OK gt in the Local Playback Screen to start the operation or click Cancel to abort the playback e View the video playback using the Playback controls e After playback click Live to return to live video 4 3 3 To Playback Local avi Files To play back the avi video files that you downloaded and stored on the PC s hard drive use Windows Media player or other media players follow these steps e Start your Windows Media Player Real One player or other media player from Start menu or any other possible access e Select File and then Open e Select the wanted avi file and then click Open NOTE The avi video can be played back in single channel full screen mode only because the files stored for each channel are separated www dynacolor com tw 125 All rights reserved User s Manual 4 3 4 4 4 126 DYNACOLOR Ke Playback Controls When playing back local or remote video DynaRemote is in Playback Mode The playback controls toolbar is on the main window as shown in the following figure Play Pause Stop Fast Rewind Fast Forward The Playback controls and indicators are described below Fast Rewind Click to play the recorded video in reverse direction Cl
96. low other computers to connectto this computer through the Internet a phone line or a direct cable connection Connect directly to another computer lt Back Next gt Cancel 104 www dynacolor com tw All rights reserved DYNACOLOR Ve User s Manual e Choose the modem device that will be used by the PC and click lt Next gt r 7 New Connection Wizard Devices for Incoming Connections You can choose the devices your computer uses to accept incoming connections Select the check box next to each device you wantto use for incoming connections Connection devices v 533 Conexant D480 MDC V 92 Modem lt Back Next gt Cancel e In Incoming VPN Connection menu choose Do Not allow virtual private connections and click on Next r 4 New Connection Wizard Incoming Virtual Private Network VPN Connection Another computer can connectto yours through a VPN connection Virtual private connections to your computer through the Internet are possible only if your computer has a known name or IP address on the Internet If you allow VPN connections the system will modify the Windows Firewall settings to allow your computer to send and K VPN packets Do you wantto allow virtual private connections to this computer Allow virtual private connections 9 Do notallow virtual private connections Back Next gt Cancel
97. ls interfacing with non standard or custom equipment or improper maintenance No Other Warranties The above warranty substitutes for all other warranties including express or implied but not limited to the implied warranties of merchantability and fitness for a particular purpose No oral or written information or advice given by DynaColor Inc its distributors or dealers shall create any other warranty and you may not count on such information or advice No Liability for Consequential Damages In no event will DynaColor Inc be liable to you for damages including any loss of data loss of profits or other incidental or consequential damages cause of your use of the Software or its documentation This limitation will apply even if DynaColor Inc or an authorized distributor or dealer has been advised of the possibility of such damages Further DynaColor Inc does not warrant that the operation of the Software will be uninterrupted or error free General If any clause of the agreement is found to be unlawful void or impracticable for any reason then that clause shall be detached from this agreement and shall not affect the validity and enforceability of the remaining provisions You should keep proof of the license fee paid including model number serial number and date of payment and present such proof of payment when service or assistance covered by this warranty is requested 6 www dynacolor com tw All rights reserved DYNACOL
98. mask XXX XXX XXX XXX 4 Gateway XXX XXX XXX XXX 5 DNS XXX XXX XXX XXX 6 PPPoE Account 7 PPPoE Password 8 PPPoE Max Idle 35min 9 Connect At Booting YES 10 Network Restart NO DHCP This item allows user to obtain a dynamic IP address from DHCP Dynamic Host Configuration Protocol server during the unit boots up When using DHCP the settings are dynamic and will change from time to time depending on your network s setup If the item is enabled ON a dynamic IP will be assigned to DynaGuard 200 series unit In this case user does not need to configure a static IP and the Ethernet settings including IP address Netmask Gateway and DNS settings will be read only The default setting is ON If you are using permanent addressing set DHCP to OFF for setting the IP Address Netmask Gateway and DNS See your network system administrators or IT personnel for appropriate values for these settings IP The item is used to configure the IP Internet Protocol address of the unit The IP address is the identifier for your computer or device on a TCP IP LAN or WAN Please note that to set a static IP address DHCP must be set to lt OFF gt Netmask This item allows user to enter the 32 bit Netmask for the unit To configure the item DHCP must be set to lt OFF gt www dynacolor com tw 57 All rights reserved User s Manual 58 DYNACOLOR Ke Gateway Users are allowed to specify the IP address o
99. mber of copies you require you may use the Software and accompanying material no more than the licensed number of copies at one time The Software is only licensed for use with specified DynaColor Inc supplied equipment Copyright The Software is a proprietary product of DynaColor Inc and is protected by copyright laws Other Rights and Limitations A demonstration copy of the Software is considered purchased and is covered by this license agreement e You may not sub license rent or lease the Software but you may transfer the Software to another party by delivering the original disk and material as well as this license to the other party Initial use of the Software and accompanying material by the new user transfers the license to the new user and constitutes the new user s acceptance of its terms and conditions e You may not de compile disassemble reverse engineer copy transfer or otherwise use the Software except as stated in this agreement e The hardware software key where applicable is your proof of license to exercise the rights granted herein and must be retained by you e DynaColor Inc reserves the right to revoke this agreement if you fail to conform the terms and conditions of this agreement In that case you must destroy all copies of the Software and all of its component parts e g documentation hardware box software key e The Software may contain software from third parties that is licensed under a se
100. mmunications port Click lt RS485 Setup gt to display the RS485 Setup menu www dynacolor com tw 135 All rights reserved DYNACOLOR Ke Configuration System Setup Language Unit ID Date Time Unit Name Password Bits Network Setup Stop Audio Output Parity Key Beep Baud Rate Monitor Setup Camera Setup Record Setup Event Setup J OK X Cancel vf Apply Unit ID This item is used to change the RS 485 ID address of the unit The ID is in the range of 1 to 255 The default is lt 224 gt NOTE NO two units on the same bus should have the same RS485 ID Baud Rate The item allows user to specify the baud rate for RS485 port The options for associated with the protocol are 2400 4800 9600 19200 and 38400 The default is 9600 baud Bits User can specify the bits that are associated with the protocol The available options are 6 7 and 8 bits The default is 8 bits Stop User can specify the stop bit associated with this protocol Options are 1 and 2 stop bits The default is 1 stop bit Parity This item is used to specify the parity associated with this protocol Options are ODD lt EVEN gt and lt NONE gt The default is NONE www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual 5 1 7 Audio Output The item is used to set the audio output mode The available options are as follows lt Live
101. ncmenseteamecenencnes 99 2 Sle NINN P s 59 3 From To TIME acess eccterscteccceechcecdeectccednetienedeasteucds 594 SOIC EVCING uou ir E E E EE N E bl liri 595 DataType eU 590 Export FOMA citation 5 9 7 Digital Signature eee 599 EN 0o 35 co T 59 9 Begin 9 0 ae post s tuin ee ee ii bota que eec nis SM LEM LIT e ors DE Appendix A Technical Specifications Appendix B Record Duration eeeeeesses Appendix C Dial up Connections via Modem Establishing Dial in Connection ocio eoe ciet eo poete sete Establishing Dial out Connection sssss Appendix D Verifying Digital Signature DynaRemote Software T e E 2 System Requirements cciericciscsnscsiedscisssicniustecsuedciensstetiecussasunninns 3 Getting Start of Installation esee 3 4 Changing Internet Settings s 3 2 installing Remote Software eere teer re rere eaa tetuer a arare pa tus 321 AO LOO DIL ueterem S ertet tect 3 2 2 Software Upgrades eee 4 Basic OperallOn uus iasasci usu uen a epbrba p EbRr LE o SMEuEE DE p EFRE REM ME LEER pAPaE 41 TO NEE E 4 1 1 Selecting Display Mode 4 1 2 Assigning Camera to Windows 4 1 3 Operating Cameras wit
102. nd Event recorded video in Purge Data menu The administrator password is required to access the function Select Record Setup from Main menu and then in Record Setup menu move the cursor to Purge Data and press ENTER the Purge Data menu is displayed Purge Data 1 Purge All Normal Data NO 2 Purge All Event Data NO 3 Purge Event Before 2005 01 01 4 Purge Event Items 5 Start to Purge NO The first four items are used to select the data that should be purged The items are described as follows After select the data you want to purge set the fifth item Start to Purge to YES and press ENTER to start the deleting process 40 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Purge All Normal Data Select the item to delete all normal recorded video from database Purge All Event Data Select the item to delete all event video from database Purge Event Before The item is used to delete event video that recorded before a specific date Purge Event items The item is used to select the event video you want to delete Select event item and confirm the deletion by pressing UP DOWN and ENTER keys choose lt YES gt to start the deleting or choose lt NO gt to abort the process 4 5 Exporting Recorded Video The Video Export menu enables the administrator to export recorded video with digital signature to a USB ThumbDrive a CD RW or to DVD RW drive Administrator s passwor
103. nects to the unit In Network Setup menu select lt Dial out Setup gt and press ENTER to enter the Dial out menu The menu displays as follows Dial out Setup 1 Dial out DHCP OFF 2 Dial out IP 0 0 O 0 3 Dial out Netmask 0 0 O 0 4 Dial out Gateway 0 0 0 O 5 Dial out DNS 0 0 O 0 6 Phone Number T Dial out Account 8 Dial out Password 9 Dial out Idle Time OFF 10 Dial out Max Time OFF 11 Connect NO Dial out DHCP This item allows user to obtain a dynamic IP address from DHCP Dynamic Host Configuration Protocol server over modem connection If the item is enabled ON a dynamic IP will be assigned to DynaGuard 200 series unit In this case user does not need to configure a static IP and the following settings will be read only Select ON to enable the DHCP function or OFF to set the dial out IP address Netmask Gateway and DNS manually The default setting is ON Dial out IP The item is for setting a static IP address that identifies the DynaGuard 200 series unit over modem connection Set the Dial out DHCP gt to OFF for accessing this item www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Move the cursor over lt Dial out IP gt and press ENTER and then press UP DOWN buttons to change the values in the selected field Dial out Netmask The item is for setting the Netmask that identifies the DynaGuard 200 series unit over mod
104. nertensie 35 Alil WMI Me 35 4 1 2 Digital ZOOM me ee oe ee a eRe ae REE ee 35 dka aN Live Cameras E 36 Viewing in Sequence Mode c oiucinee neos eene conecocoieueaeueieie 36 Te Freeze Live ut iib ine be loculi lou ede 36 4 14 Viewing Recorded EIER 36 Button Usage in Playb CK e 37 Pause Playback and Single Step Forward ssesse04 37 Viewing Live Image in Playback Mod ccccccccccceceeeeeneeeeeeeeeeenenee 37 www dynacolor com tw 7 All rights reserved User s Manual DYNACOLOR Ke 4 2 Call Monitor Control EE 38 43 Searching Recorded OO EE 38 eee Dy TIME EP os 39 Search DY EVEN orso e E a E E e E RE 39 4A D leting R corded Vide E 40 45 Exporting Recorded M9 E 41 235 1 Select RE 42 Mee reel VIGO P 42 4 5 3 Digital Signature eee ee ee ee ee en ee 43 so MEI 310 E 44 46 Dome Control tete 44 SCH Dome Connectoren esse geegent 44 4 6 2 Dome Protocol Setup E 45 46 3 MM o gt a SGUD a ee amet EEEE RESEP eee ee 45 20 3 Dome Controlling Er 46 46 5 Setting Preset E 47 4 6 6 Calling Preset Ebenen 48 b Advanced EE e E e UI E 50 SNEE UE 0 50 SL Verlo E E E E E EEEE 51 SLI Hardware Versio WEE 51 EN Sotware Verslo eee ne RESE eer eer eer ee re 51 5 1 1 3 Software Upgrade via Local Device 51 5 1 1 4 Software Upgrade via Internet ssss 52 512 Langage EE 52 gL Dater TME T
105. ns are lt 3 gt lt 5 gt lt 7 gt lt 9 gt and lt 11 gt KB Event Max PPS Event Max PPS is used to set the event recording rate for Event status Normally the Event PPS is set to equal or greater than Normal PPS the setting is depending on your application If the Event PPS is set to lt 0 gt DynaGuard 200 series unit stops recording event video during alarms Event Size The item is used to set the picture size for event status recording The available options are lt 3 gt lt 5 gt lt 7 gt lt 9 gt and lt 11 gt KB www dynacolor com tw All rights reserved DYNACOLOR Ke 5 4 4 6 5 4 5 5 4 6 5 4 7 User s Manual Event Active Users are allowed to choose which alarm type needs to be recorded The available options are lt Alarm gt alarm events lt Motion gt motion detection events lt Both gt alarm event motion detection and lt None gt no events active The default setting is lt Both gt which includes Alarm and Motion event recording Event Percentage The item is used to set the event recording percentage of total capacity The unit stops recording event video when the event space is full To set the event percentage select lt Event Percentage gt in Record Setup menu and press ENTER and then use UP DOWN buttons to set the event percentage Data Lifetime Data Lifetime indicates the time that a recording is saved and remained in the HDD between the creation and d
106. o four Users can access a DynaGuard 200 series unit at the same time Furthermore if the Admin account is currently accessing the unit OSD menu via front panel of the unit then you cannot save information as an Admin on DynaRemote The DynaGuard 200 series unit Admin account has priority 116 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Enter Network Password qe This secure Web Site at 192 168 7 184 requires you to log on Please type the User Name and Password that you use for DG200 User Name Y Password E Iw Save this password in your password list Cancel The following steps demonstrate procedures to view video from remote unit e Start DynaRemote by entering the IP Address of the remote DynaGuard 200 series unit in the Address field of the browser Or you may click on the Favorite entry for the unit if the IP address of the unit has been set e Enter your Username and password You can save password in the list if needed The default usernames and passwords are listed as below Login Type Default User name admin user Default Password 1234 4321 e Click OK to log in to the remote DynaGuard 200 series unit The process may take a few seconds e If the connection is made successfully the main window displays live video of the attached cameras If you close the IE browser you log off the system at the same time 3 2 2 Software Up
107. ode a 9 window viewing mode contains both live and playback image appears This view mode is illustrated as the following figure www dynacolor com tw 37 All rights reserved User s Manual 4 2 4 3 38 DYNACOLOR Ke The four windows on the top left of the screen playback the recorded video from channel 1 to channel 4 respectively and the other windows allow user to view live image from channel 1 to channel 4 Call Monitor Control Users are allowed to use the DynaGuard 200 series unit front panel to control a call monitor display without having to access the Main menu Two viewing modes can be displayed on call monitor Sequence display and Single camera display To program the call monitor sequence see section 5 5 Sequence Setup Follow the steps to control the call monitor e Press the CALL button on the front panel to enter call monitor control mode the message Call Mode will be shown on the bottom left of the screen Press 1 8 Key To Select Channel Press SEQ To Enable Sequence Call Mode e Press CHANNEL button to display the associated camera on call monitor e Alternatively press SEQ repeatedly to display the sequence of cameras previously programmed in Call Monitor Schedule menu e Press ESC to return the front panel to Main monitor control mode Searching Recorded Video The DynaGuard 200 series is capable of searching and playing back recorded video by date and time or events Ent
108. oes PAL Tass E ee tee Nm Standard COSA 9 KB op AD 13 KB Both Seen Golpe ske SONTSC 43KB Both Event Only OP bo ae SE 13 KB Both 128Kbps DSL TE Se 2 KB p SE 2KB Both 256Kbps DSL i A 2 KB e NE 2KB Both 512Kbps DSL vp bi 3 KB Ge SC 3 KB Both OF seed Selected ae elected Ueereclectes AN NOTE If selecting this Record mode only the image from channel 1 4 will be recorded Record Mode Half D1 mode NTSC 720x240 60PPS PAL 720x288 50PPS Preset Normal Normal Event Event Event Active Configuration PPS Size PPS Size Best Quality on Gas WRB Geran TKB eae aon Standard E 7 KB eh SE 14 KB Both s 62S PAL 3 KB aspi AE 11 KB Both Event Only E E 14 KB Both www dynacolor com tw All rights reserved DYNACOLOR Ke 5 4 4 User s Manual 128Kbps DSL i EE 2 KB TE EE 2 KB Both 256Kbps DSL i Mit 2KB vs NE 2KB Both 512Kbps DSL io 3KB e Se 3 KB Both Or Saeed veer Jeep elected UserSelectes Record Mode CIF mode NTSC 360x240 120PPS PAL 360x288 100PPS Preset Normal Normal Event Event Event Active Configuration PPS Size PPS Size SES OZS PAL is SPAD SAB iiam Ween Standard bg 5 KB OBP nt 9 KB Both Sa Lee de Sea aie Both Event Only s oe RE 9 KB Both 128Kbps DSL EE 2KB n4 RE 2 KB Both 256Kbps DSL i nats 2 KB UP GE 2 KB Both 512Kbps DSL Mi 3KB e ep 3 KB Both ORF E E E
109. ons to observe Daylight Saving Time Select lt ON gt to enable or lt OFF gt to disable the function If the function is disabled the DST Start End time and DST Bias will be grayed out and cannot be accessed NOTE If this function is enabled the date time information will be shown on the screen with a DST icon when playing back recorded video or searching video in the event list S indicates summer time and W indicates wintertime www dynacolor com tw 29 All rights reserved User s Manual 3 5 3 5 1 30 DYNACOLOR Ke DST Start End The items are used to program the daylight saving duration Use Direction keys to move the cursor to the next or previous field UP DOWN to change the settings in the selected field DST Bias The item allows user to set the amount of time to move forward from the standard time for daylight saving time The available options are lt 30 gt lt 60 gt lt 90 gt and lt 120 gt minutes Record Schedule Quality Setting The Record Setup menu allows user to set recording quality recording schedules and other recording parameters Administrator s password is required to use Record Setup menu In the Main menu move the cursor to lt Record Setup gt and press ENTER the following menu is displayed Record Setup 1 Record Mode 720x240 60PPS 2 Schedule Setup 3 Preset Config Standard 4 Per Camera Config 5 Event Percentage 20 6 Data Lifetime 7 Days 7 P
110. oos Advanced Hep a Osa QP seo res Ae Address Network Connections GEZ Broadband network Tasks E E Create a new connection SL erch Wi Dos f setup a home or small CO wa d office network Change windows Firewall Dial up settings v SIT Yahoo Connection KZ Ci See Also 2 A Network Troubleshooter Other Places a D Control Panel My Network Places ny pocumenes LAN or High Speed Internet M My Computer Local Area Connection 3 E 1394 Connection 7 Local Area Connection 4 Di Firewaled Disabled Frewaled gt Connected Frewallec C alla Bro C dh 1394 Net Adapter 45 CA D Link DE660 P apte Details Network Connections System Folder www dynacolor com tw 107 All rights reserved DYNACOLOR Ke User s Manual Appendix D Verifying Digital Signature The digital signature aims to authenticate a video file exported from the unit Follow the description to export video with digital signature and verify the digital signature To export recorded video with digital signature To export recorded video with digital signature to a USB hard drive or CD RW drive DVD RW drive follow these steps e n Video Export menu select copy device data type expected channel and start end time or event video clips e Set the Digital Signature function to YES e Start exporting process by setting Begin Export to YES Video Export 1 Select Device 2 Select Ch CH1
111. or cannot remember or locate the password There are three options to select from lt Admin gt reload the Admin password only lt User gt reload the User password only and lt All gt reload the Admin and User passwords The factory password is 1234 for administrator and 4321 for user Network Setup The Network Setup menu allows the administrator to configure the network by specifying the network related settings such as IP address Netmask etc See your network administrator and or network service provider for more specific information From the System Setup menu select lt Network Setup gt and press ENTER The following menu is displayed Network Setup LAN PPPoE Select LAN LAN PPPoE Setup Dial in Setup Dial out Setup Trigger Ort 80 Email Address SMTP Setup DDNS Setup ONDAN Items in this menu are described in the following sections LAN PPPOE Select Select the service type between LAN lt PPPoE gt or None and access the LAN PPPoE Setup menu for further settings LAN PPPoE Setup The network related settings in the LAN PPPoE Setup menu should be associated with the network service type Select lt LAN PPPoE Setup gt in Network Setup menu and press ENTER for setting the parameters the menu displays as follows www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual LAN PPPoE Setup 1 DHCP ON 2 IP XXX XXX XXX XXX 3 Net
112. or each connected camera The menu is shown as below Camera Setup 1 Camera Select CH1 2 Dome Protocol None 3 Dome ID 0 4 Camera Title 5 Covert NO 6 Termination NO 7 Brightness 0 8 Contrast 0 9 Saturation 0 10 Hue 0 11 Audio Association Both www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Items in this menu are described in the following subsections 5 3 1 Camera Select The item is used to select a desired camera for setting the parameters The related settings will follow the selected camera such as dome protocol and camera title Move the cursor to lt Camera Select gt and press ENTER then select a channel using UP DOWN buttons 5 3 2 Dome Protocol Select the communications protocol associated with your dome camera using the ENTER and Direction buttons The available protocol includes lt DynaColor gt lt Pelco D gt lt Pelco P gt lt AD422 gt and lt None gt default 5 3 3 Dome ID This item is used to assign an ID number to the selected dome camera Note that ID number must match the ID address set by the dome 5 3 4 Camera Title This item allows the user to change the title of each camera connected to the unit By default the titles of cameras are numbered from 1 through 8 respectively The title is displayed on screen after changes from this menu are entered Follow these steps to enter a new title for a camera e Inthe Camera setup Menu move the curs
113. or over the item and press ENTER for adjusting the chrominance of image displayed on the monitor Use UP DOWN buttons to adjust the numeric value The range of chrominance values is lt 128 gt to 127 the default setting is 0 5 2 5 Screen Center Adjust The item is used to adjust the screen center of the main monitor display area Follow the steps to set the center point e Select lt Screen Center Adjust gt from the Monitor Setup menu and press www dynacolor com tw 71 All rights reserved User s Manual 5 2 6 5 2 7 5 3 72 DYNACOLOR Ke ENTER The adjusting screen is as follows Screen Center Adjust A lt gt v e Position the screen center position using the Direction buttons e Press ENTER to exit when finished Show Color Bar Choose this item to display a color bar pattern on the screen The color bar helps to adjust the monitor hue saturation text color and display options Press ESC to exit the color bar pattern and return to the OSD menu VGA Resolution The item allows user to select appropriate VGA resolution for the VGA monitor connected to the unit The options are 800x600 default 1024x768 and 1280x 1024 NOTE If the selected VGA resolution is too high for the monitor the message No Signal will be shown on screen Camera Setup The items in the Camera Setup menu enable user to set camera parameters including camera title dome protocol and ID f
114. or to Camera Title and press ENTER A virtual keyboard with alphanumeric characters is displayed www dynacolor com tw 73 All rights reserved User s Manual 5 3 5 5 3 6 74 DYNACOLOR Ke Camera Title O Oo Es o 4 c X x lt 3 N Z a c e f g h i j k I n o q rs t u vw xXx y z 0 1 3 4 506 7 8 Q9 go 4 Backspace Delete Cancel OK e Use Direction buttons to position the cursor in the title entry field above the virtual keyboard e Use Direction buttons to move the cursor through the lists of characters to the one you need Press ENTER to select a character Continue until the name is established You can enter up to 11 characters from those listed in the virtual keyboard e After title entry is finished move the cursor to OK and press ENTER otherwise either press ESC or move the cursor to Cancel and press ENTER to abort Covert This function allows user to choose certain camera to be covert while the unit is continuing recording video Choose a desired channel by Channel Select first and then move the cursor to lt Covert gt and press ENTER following that use UP DOWN buttons to select YES camera covert or NO camera non covert The default setting is lt NO gt Termination This item is used to enable disable the 75 termination resistor inside the unit to adjust the image quality of each camera lt YES gt termination resistor enabled default
115. ote Click and drag NOTE The CAMERA button displays with a dome icon when the corresponding camera is equipped with dome control 120 www dynacolor com tw All rights reserved DYNACOLOR Ke 4 1 3 User s Manual Operating Cameras with Dome Control DynaRemote allows you to control and configure a dome camera remotely Click on any CAMERA button to view the camera in full screen display Then click on a CAMERA button which is displayed with a dome icon The Dome Control Panel shown as right will be displayed in the left side of the main window The items on the dome control panel are described as follows Set Preset Points This item ll is used to set up preset positions DynaRemote allow setting up to 255 preset positions with DynaColor American Dynamics and Pelco Pelco P amp Pelco D domes Use Direction buttons to move dome camera to an appropriate position and then click the button and choose wanted number from the pull down list The preset position is named as the selected number Go Preset Point This item is used to call the camera preset point which was set up with the set preset function Click and choose a number to call the preset for viewing A F Auto Focus Click to focus the camera automatically for a clear view ID Dome ID Setup Click for changing the dome ID and protocol User privileges in not allowed to change the dome ID and protocol Admin privileges is needed
116. pacity of HDD that has been added into database The Free Size of HDD indicates the free space for recording of the HDD added in database The information is read only 5 7 2 Rest Normal Event REC The Rest Normal Event REC indicate the rest duration for normal and event recording respectively If recording video in circular mode the item will show Circular The information is read only 5 7 3 Internal External Disks Select lt Internal Disks gt or lt External Disks gt to see information on the storage devices connected to the unit The submenu is displayed as below Internal Disks Name Active Action XXX XXXXXXX XXXXXX YES None The information of built in HDD and external storage device will be listed by model name and status If no storage device connects to the unit the message No Available Items will show on screen NOTE If the file system of the internal HDD is not compatible for the DVR the system will format the internal HDD automatically without notice lt Active gt The item indicates if the storage device is added into database or not lt YES gt means the device has been added into database www dynacolor com tw 89 All rights reserved User s Manual 5 8 5 8 1 5 8 2 90 DYNACOLOR Ke lt Action gt The item allows user to add storage device into database or remove device from database The options are lt None gt no action lt Add gt add the selected dev
117. parate End User License Agreement Read and retain any license documentation that may be included with the Software Comply with the terms of any third party End User License Agreement is required as a condition of this agreement www dynacolor com tw 5 All rights reserved DYNACOLOR Ke User s Manual Failure to comply with these restrictions will result in automatic termination of this license and will make available to DynaColor Inc other legal remedies Upgrades If the Software is an upgrade from another software version you may use or transfer the Software only as specified in this agreement If the Software is an upgrade of a component of a package of Software programs that you licensed as a single product the Software may be used and transferred only as part of that single product package and may not be separated for use on more than one computer Limited Warranty Company s warranty for security product is limited to the repair or comparable replacement of any merchandise proved defective in material or workmanship except normal wear and tear for a period of two years except for HDD and CD RW component which carry a 6 month guarantee The warranty does not apply to the appearance of the product or accessory items and does not cover damage which occurs in shipment or failure which results from alternation accident misuse neglect voltage fluctuation lightning water damage faulty installation or adjustment of contro
118. plays e Use Direction buttons to select character e Press ENTER to add the selected character to the password entry field e When done move the cursor to lt OK gt and press ENTER to save the settings and exit PPPoE Max Idle The item Indicates the time that the modem connection remains active if there is no acknowledgement from the remote PC The default is 35 minutes Connect At Booting The unit is allowed to connect to the internet automatically when powered up Select YES to connect at booting otherwise select NO Network Restart Network restart is required after changing network settings Select YES to restart the network connection Dial in Setup The Dial in function enables user to establish dial up modem communication to and from DynaGuard 200 series unit for the remote software use User can connect one modem to a DynaGuard 200 series unit For more information on dial up setting on PC see Appendix C Dial up Connections via Modem NOTE Do not enable the Dial in Service if no modem connects to the unit In Network Setup menu select Dial in Setup and press ENTER to enter the Dial in menu The menu displays as follows www dynacolor com tw 59 All rights reserved DYNACOLOR Ke User s Manual Dial in Setup 1 Dial in Service OFF 2 Dial in Account 3 Dial in Password 4 Server IP 0 0 0 O 5 Client IP 0 0 O O 6 Dial in Idle Time OFF 7 Dial in Max T
119. provider for more specific information To setup the Dial out Account follow the steps e Select lt Dial out Account gt from Dial out Setup menu and press ENTER A virtual keyboard displays Dial out Account A B CD F GH iI J M N O Q RST VWXYZ a b c e f g h i j kim n o q rs t u vw xXx y z 0 1 3 4 5 6 7 8 9 Q9 gt Backspace Delete Cancel OK e Use Direction buttons to move the cursor to the wanted character e Press ENTER to add the selected character to the username entry field e When done move the cursor to lt OK gt and press ENTER to save the settings and exit Dial out Password The item allows user to setup the Dial out password Follow these steps to setup the login password e Select lt Dial out password gt from Dial out Setup menu and press ENTER A virtual keyboard displays e Use Direction buttons to move the cursor for selecting character e Press ENTER to add the selected character to the password entry field e When done move the cursor to lt OK gt and press ENTER to save the settings and exit www dynacolor com tw All rights reserved DYNACOLOR Ke 5 1 6 5 5 1 6 6 User s Manual Dial out Idle Time This item indicates the longest amount of time that the modem connection remains active if there is no acknowledgement from the remote pc The value can be set in the range of 1 min to 600 min If selecting lt OFF gt the modem connection keeps active continuously
120. ras e Alarm notification from the DynaGuard 200 series unit e Up to five connections to one DynaGuard 200 series using DynaRemote including one Administrator and four User operators www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual 2 System Requirements Items Minimum Requirements Personal Computer Pentium 3 600 MHz processor Pentium Celeron or Pentium 4 1 5GHz processor preferred RAM 256 MB minimum Hard Drive 20 MB available for software installation Operating System Windows XP 2003 Windows 2000 Web Browser Microsoft Internet Explorer version 6 0 or above The minimum monitor screen resolution Monit xd requirement is 1024 x 768 with 16 bit color Video Card XVGA with 16 MB video RAM 10Base T 10 Mbps or 100Base TX 100 Mbps Network Card l ps l ps operation must match the network configuration 3 Getting Start of Installation Refer to the following description to install the DynaRemote remote control software 3 1 Changing Internet Settings The PC you want to operate with DynaRemote should be set to accept ActiveX plug ins Please follow the steps to set the Internet security settings appropriately e Before you operate the remote software please check the IP address of your DynaGuard 200 series unit To check the IP address press MENU key on the unit and enter password to access OSD Main menu select lt System S
121. re Alarm Recording 15 Sec 8 Circular Recording ON 9 Audio Recording ON 10 Purge Data Record Mode The Record Mode is for selecting resolution and recording rate The relative record settings such as preset configuration will follow the record mode setting The options are lt 720x480 30PPS gt lt 720x240 60PPS gt and lt 360 x240 120PPS gt in NTSC lt 720x576 25PPS gt lt 720x288 50PPS gt 360x 288 100PPS gt in PAL Move the cursor to lt Record Mode gt and press ENTER then select a Record mode using UP DOWN buttons NOTE If selecting the Record mode lt 720x480 30PPS gt 720x 576 25PPS only the image from channel 1 4 will be recorded www dynacolor com tw All rights reserved DYNACOLOR Ke 3 5 2 3 5 3 User s Manual NOTE After changing the Record Mode setting the warning message This will FORMAT ALL HARDDISKS and LOAD THE FACTORY DEFAULT CONFIG will show Press ENTER to confirm the selection then the unit starts to format the hard disks and load the factory default settings or press ESC to abort Schedule Setup The Schedule Setup is used to set the day and night time or weekend recording schedule Select Schedule Setup from the Record Setup menu and press ENTER the following menu is displayed Schedule Setup 1 Day Time Start 06 00 2 Night Time Start 18 00 3 Weekend Schedule YES 4 Weekend Start Fri 18 00 5 Weekend End Mon 06 00 e Make appropriate changes o
122. recorded video from the event list DynaGuard 200 series includes DynaRemote the remote viewing and configuration software that is a Web browser plug in allows user to view live or recorded video images and enables remote configuration The remote software is stored in DynaGuard 200 series and deployed over a LAN WAN or Internet connection to remote Windows based computers This simplifies the installation and maintenance of the software components so all remote users are kept up to date 1 1 Product Key Features The DynaGuard 200 series offers advanced features not typically found in standard multiplexers it integrates the full features of a DVR multiplexer and video server by using the software DynaRemote The key features of DynaGuard 200 series are listed as follows e MPEG 4 high quality compression e Compact size 4 or 8 channels video input e Triplex operation enabling simultaneous viewing live or playback while continuing to record e DynaRemote web based software for remote monitoring and control via LAN or Internet e Embedded Linux operating system e Real time live display for each channel e Recording frame rate up to 120 pps NTSC 100pps PAL e 2 Channels of audio recording playback e Three USB2 0 ports for video clip export and or backup e Two IEEE 1394 FireWire ports for storage extension e Easy software upgrade via USB ThumbDrive CD RW or Internet Remote Application www dynacolor com tw 15 All r
123. res new video over the HDD spaces If you choose to record in linear mode in stead the unit stops recording when the HDD is full From the Record Setup menu move the cursor to lt Circular Recording gt and press ENTER then select ON OFF using UP DOWN buttons Audio Recording This item allows user to enable disable Audio recording function of the unit When set to lt ON gt audio input is recorded and saved with the video When set to OFF audio is ignored The default setting is ON Purge Data This item is used to delete the Normal or Event recording video In Record Setup menu move the cursor to Purge Data and press ENTER the Purge Data menu is displayed Purge Data 1 Purge All Normal Data NO 2 Purge All Event Data NO 3 Purge Event Before 2005 01 01 4 Purge Event Items 5 Start to Purge NO Purge All Normal Data The item is used to delete all normal recorded video from database s Set this item to lt YES gt using UP DOWN buttons and start the deleting by enable YES the lt Start to Purge gt function www dynacolor com tw All rights reserved DYNACOLOR Ke 5 4 10 2 5 4 10 3 5 4 10 4 5 4 10 5 User s Manual Purge All Event Data The item is used to delete all event video from database s Using UP DOWN buttons to select lt YES gt and start the deleting by setting the lt Start to Purge gt to lt YES gt Purge Event Before The item is used to
124. reserved DYNACOLOR Ke User s Manual 4 3 To Playback Video DynaRemote allows you to view recorded video either from the remote DynaGuard 200 series unit or remote playback from the hard disk drive of your PC To access the Playback screens click lt Play gt button on the main window toolbar There are three tabbed screens are contained in the Playback screens lt Remote Playback gt lt Local Playback gt and lt Verify gt tabs The lt Remote Playback gt allows you to play back from a remote unit The lt Local Playback enables you to play back a recorded video file with DynaRemote that was downloaded and stored on the hard disk drive of your PC The lt Verify gt allows verify the digital signature to authenticate a video file exported from the unit The remote unit continues recording while you are playing back recorded video on your PC either remote playback or local playback 4 3 1 Playing Back Remote Video To view remote video click lt Play gt on the top of the main window toolbar and then lt Remote Playback gt tab The lt Remote Playback gt screen will then be displayed The lt From gt and lt To gt on the top of the screen display the date and time from which recorded video is available for playback www dynacolor com tw 123 All rights reserved DYNACOLOR Ke User s Manual To play back remote video segments follow these steps e Select the date and time of the segment to play back from t
125. rotocol includes lt DynaColor gt lt Pelco D gt lt Pelco P gt lt AD422 gt and lt None gt default Dome ID This item is used to assign an ID number to the selected dome camera Note that ID number must match the ID address set by the dome Camera Title The item allows user to set a title of camera connected to the unit up to 11 characters The title will be displayed both on the remote unit s main monitor and the DynaRemote main window Enter a camera title to the entry field using keyboard directly By default the titles of cameras are numbered from 1 through 8 respectively Covert This function allows user to choose certain camera to be covert while the unit is continuing recording video Choose a desired channel first and set the item lt Covert gt to lt YES gt lt YES gt camera covert lt NO gt camera non covert The default setting is lt NO gt www dynacolor com tw 139 All rights reserved User s Manual 5 4 140 DYNACOLOR Ke Termination This item is used to enable disable the 75Q termination resistor inside the unit to adjust the image quality of each camera channel lt YES gt termination resistor enabled default lt NO gt termination resistor disabled NOTE If the camera loop out connectors have not been used the termination resistor should be enabled for appropriate signal termination Brightness The item is for adjusting the image s brightness darkness of the s
126. rted clip has not been altered www dynacolor com tw 109 All rights reserved DYNACOLOR User s Manual 7 Playback Remote Playback f Local Playback Filename gpd NAZO0S0602 135607 89641062 gpg Filename N 0050602135607 ORMALVcTI 0 a mere CRTs Status Log Verified Good signature from 00D089641062 GOOD Signature Playback Remote Playback Local Playback It 200506021 Seege gpg ame m 2005002435607 ORMADSchOLD a m er Emer 00 sig Bad TRTE Avi file and signature dont match lt BAD gt Signature 110 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual www dynacolor com tw 111 All rights reserved User s Manual 112 DYNACOLOR Ke Overview DynaRemote is a remote browser based software application designed to operate with DynaGuard 200 series products Using the software users are allowed to view live and recorded video and also to configure DynaGuard 200 series units remotely via a LAN WAN Internet on your personal computer The DynaGuard 200 series unit automatically downloads the DynaRemote plug ins to the connected PC when you connect to DynaGuard 200 series unit by entering the IP address of the unit in the address field on the browser The tasks can be performed with DynaRemote are listed below e Remote viewing of live recorded video e Remote setup of DynaGuard 200 series unit e Remote control of dome came
127. s If any item is missing or if damage is evident DO NOT INSTALL OR OPERATE THIS PRODUCT Contact your dealer for assistance Rack Mounting Consult with the supplier or manufacturer of your equipment rack for the proper hardware and procedure of mounting this product in a safe fashion Avoid uneven loading or mechanical instability when rack mounting units Make sure that units are installed to get enough airflow for safe operation The maximum temperature for rack mounted units is 40 C Check product label for power supply requirements to assure that no overloading of supply circuits or over current protection occurs Mains grounding must be reliable and uncompromised by any connections 4 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual End user License Agreement Read this License Agreement before opening the package or installing the software The License Agreement describes your rights and obligations By breaking the seal on the package or installing the software you agree to all the terms in this agreement Software License The Software includes the computer software the associated media any printed material and any electronic documentation and may be provided to you installed on a hard drive the media as part of a system The Software is licensed not sold Grant of License This agreement between you and DynaColor Inc allows you to use the Software you purchased Once you have purchased the nu
128. s dialog will show twice for confirmation click YES to accept ActiveX plug ins The DynaRemote plug ins will be downloaded and instaled on your PC automatically when the connection is successfully made NOTE Do not enter any leading O characters in the address for example 192 068 080 006 should be entered as 192 68 80 6 If www dynacolor com tw 115 All rights reserved DYNACOLOR Ke User s Manual the default trigger port 80 is changed into another one port 81 for example you should enter the IP address as 192 68 80 6 81 Internet Explorer r Do you want to allow software such as ActiveX controls e and plug ins to run e A version check starts to verify whether DynaRemote was installed already and also check if the version is the same as that stored on that particular DynaGuard 200 series unit This process may take up to 30 seconds e When the software is completely downloaded the Login Screen is now displayed Enter Network Password qe This secure Web Site at 192 168 7 184 requires you to log on Please type the User Name and Password that you use for DG200 User Name X Password Ke IV Save this password in your password list Cancel 3 2 1 Log in Log off You can log in using the Admin or User account Admin accounts can perform unit configuration freely while User account has more limitation on remote access to the unit One Admin and up t
129. s in the menu will be described in the following section 5 9 1 Select Device The available external devices for exporting video will be listed by name and free size in Select Device menu The Select Device menu displays as follows Select Device Device Name Available Sel XXX XXX X X XX 256 MB NO XX XXX XX XXXX 1 5 GB NO The DynaGuard 200 series only supports EXT3 file system If you connect an external HDD to the unit ensure the format of HDD is EXT3 Device Name The item shows the name of the available device Available The item shows the free space of the available device Select Set the item to YES to start the export or NO to cancel 5 9 2 Select Channel The item is used to select channels for export Move the cursor to the wanted channel using LEFT RIGHT buttons select or de select a channel by pressing ENTER 5 9 3 From To Time The items are used to set the time which data export begins and ends Move the cursor using Direction buttons and press ENTER to select the date time items adjust the selected date and time value by UP DOWN buttons NOTE When the Start End Time are set remember to select the exporting Data Type www dynacolor com tw 93 All rights reserved User s Manual 5 9 4 5 9 5 5 9 6 5 9 7 94 DYNACOLOR Ke Select Events Select the item to display the event list for exporting event video Move the cursor scroll the event list and press ENTER to select
130. s reserved DYNACOLOR Ke User s Manual e Press ENTER to add the character to the entry field up to 11 characters e When done move the cursor to lt OK gt and press ENTER to save the settings and exit 5 1 5 Password The Password menu allows administrator to change the password settings for accessing the unit Select Password in System Setup menu and press ENTER the menu displays as follows Password 1 Admin Password 2 User Password 3 Enable Password NO 4 Load Factory Password None 5 1 5 1 Admin User Password Only the administrator is allowed to change the user and administrator password to any 4 8 digit number Use the UP DOWN Direction buttons to select the desired account and press ENTER the following menu is displayed Admin Password Press Channel Keys To Enter Password 4 8 Digits Press 4 To Delete Use CHANNEL buttons to input the new password and confirm the new password After setting the new password press ENTER to save the settings and exit 5 1 5 2 Enable Password The item is used to determine if the password is required for accessing the OSD menu Select YES to demand entering password when accessing the OSD menu if not select NO www dynacolor com tw 55 All rights reserved User s Manual 5 1 5 3 5 1 6 1 5 1 6 2 56 DYNACOLOR Ke Load Factory Password This item allows the administrator to reload the factory password in case that the administrat
131. s restarting Iess e Follow the steps to set up web port forward to DVR 2 A Click lt Enabled gt to set up the service Enter the name of the setting in the Name field DVR 2 Enter Private IP 200 Choose lt TCP gt as the Protocol Type Enter Private Port 81 Enter Public Port 81 Click lt Always gt for the Schedule setting Click lt Apply gt Zomm Do D e Now you can see DVR 1 via http 218 160 54 13 80 and DVR 2 via http 218 160 54 13 81 e If there are more than one DVR behind the router repeat the steps for port mapping setting www dynacolor com tw 153 All rights reserved
132. sferred Select lt SMTP Setup gt from Network Setup menu and press ENTER the menu displays as follows SMTP Setup 1 Email via SMTP NO 2 SMTP Server 3 SMTP Port 25 4 SMTP Username 5 SMTP Password Email via SMTP The item enables user to determine if the unit sends e mail via SMTP Select lt YES gt to send e mail via SMTP using direction buttons if not select lt NO gt SMTP Server This item enables user to set the SMTP server See your network service provider for more specific information Follow the steps to setup the SMTP Server e Select lt SMTP Server gt from SMTP Setup menu and press ENTER A virtual keyboard displays SMTP Server A B D F GH iI J M N O QRS T VWXYZ a c d e f g h i j m n o q r s u v w Xx yz 0 1234567899 m m uu 4 Backspace Delete Cancel OK www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual e Use Direction buttons to move the cursor to the wanted character e Press ENTER to add the selected character to the username entry field e When done move the cursor to lt OK gt and press ENTER to save the settings and exit SMTP Port The item is used to change SMTP port into another port if necessary SMTP usually is implemented to operate over Internet port 25 To change the SMTP port move the cursor to lt SMTP Port gt in SMTP Setup menu and press ENTER Use UP DOWN buttons to change the values in the selected fie
133. son to perform the installation procedure Connecting Devices to the Unit This section lists some notices that should be given before making any connections to the DynaGuard 200 series unit www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual NOTE Connect short term devices such as USB ThumbDrive USB CD RW USB Hard Disk Drive etc only after the unit is successfully powered up Connecting Required Devices Before power up the unit you should connect cameras and a main monitor to the unit for basic operation If needed connect a call monitor for displaying full screen video of all installed cameras in sequence Connecting Short term Device If you plan to install any short term devices to the DynaGuard 200 series and use them as part of the unit system such as USB CD RW USB Hard Disk Drive etc Make sure connecting those devices only during the unit is powered up Because DynaGuard 200 series unit can recognize the external devices only after the power up process are completely 2 4 Rear Panel Connections There are various connectors on the rear panel used for DynaGuard 200 series installations The following figure shows the connectors by name and followed by the detailed description of each connector Note that 8 channel DynaGuard 200 series unit has 8 camera inputs and camera looping out connectors on the rear panel respectively Main Monitor Call Monitor Power Power BN
134. ss Router ideal for home networking and small business networking The setup wizard will guide you to configure the DI 724P to connect to your ISP Internet Service Provider The DI 724P s easy setup will allow you to have Internet access within minutes Please follow the setup wizard step by step to configure the DI 724P Wireless DELI f DHCP Help e Click the Advanced tab and follow the steps to set up web port forward to DVR 1 A Select the lt Enabled gt to set up the service Enter the name of the setting in the Name field DVR 1 Enter Private IP 167 Choose lt TCP gt as the Protocol Type Enter Private Port 80 Enter Public Port 80 Click lt Always gt for the Schedule setting Click lt Apply gt roammog D 152 www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual D Link BirPius G High Speed 2 4GHz Wireless Router Status Tools G T DI 724P Virtual Server amp Virtual Server is used to allow Internet users access to LAN services Enabled Disabled E Name virtual server HTTP Private IP 1924 68 0 167 Protocol Type TCP w Private Port E E Schedule Always Db O From Time 00 w 00 e rom v o0 Z day Sun_ to Sun_ e O O DDNS Apply Cancel Help 8 e Click lt Continue gt to go on when the following screen displays Des ir Plus G High Speed 2 4GHz Wireless Router The device i
135. ssing Direction keys and press ENTER to select characters To move the cursor in title entry Press MODE and LEFT RIGHT simultaneously to move the cursor to left right in the title entry www dynacolor com tw 27 All rights reserved User s Manual 3 4 3 4 1 28 DYNACOLOR Ke To delete previous character Select lt Backspace gt and press ENTER or press MODE and UP simultaneously To delete current character Select lt Delete gt and press ENTER or press MODE and DOWN simultaneously To exit the virtual keyboard Select lt OK gt and press ENTER to save the settings and exit or press ESC to exit without saving changes System Date Time Setting User can set the current date time and other OSD parameters in Date Time menu The administrator s privileges are required for entering the submenu In OSD Main menu select lt System Setup gt and press ENTER then select lt Date Time gt to access the Date Time menu the menu displays as follows Date Time 1 Date 2005 02 21 2 Time 10 39 26 3 Date Time Display 1 Row 4 Date Display Mode Y M D 5 Time Display Mode 24 HR 6 Date Time Order Date First 7 Daylight Saving Time ON 8 DST Start Apr 1 st Sun 02 00 9 DST End Apr Last Sun 02 00 10 DST Bias 60 Min Set Date Time Set Date Time Select lt Date gt lt Time gt and press ENTER for adjusting the settings LEFT RIGHT buttons are used to move the cursor to previous or nex
136. t field ENTER is for selecting and UP DOWN are used to change the value in the selected field NOTE The reset date time setting applies to record new video the date and time of previously recorded video will not be changed www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual NOTE To avoid record database corruption after changed date time setting clear the database is recommended Date Time Display Users are allowed to choose to set the date time OSD displays in 1 or 2 rows Use the UP DOWN buttons to change the setting The default is to display the date time OSD in one row Date Display Mode This function allows user to set the OSD display type of the date time There are three options to select from lt Y M D gt lt M D Y gt or lt D M Y gt amp Y represents Year M represents Month and D represents Day Use UP DOWN keys to change the setting The default setting is lt Y M D gt in both NTSC PAL formats Time Display Mode User can choose to set the time format to 12 hour or 24 hour Use the UP DOWN buttons to change the format The default setting is 24 hour gt Date Time Order The item is used to set the order of date time display to lt Date First gt or lt Time First gt Use UP DOWN buttons to change the setting 3 4 2 Daylight Saving Time Daylight Saving Time The item is for those people who live in certain regi
137. t the color contrast of image displayed on the monitor The range of brightness values is lt 128 gt to lt 127 gt Monitor Chrominance The function allows user to adjust the chrominance of image displayed on the monitor The range of brightness values is lt 128 gt to lt 127 gt VGA Resolution The item allows user to select appropriate VGA resolution for the VGA monitor connected to the unit The options are lt 800x600 gt default lt 1024x768 gt and lt 1280x1024 gt NOTE If the selected VGA resolution is too high for the monitor the message No Signal will be shown on screen Camera Setup The screen allows user to configure camera related items on the remote unit Click MENU button on the main window toolbar click Camera Setup to expand the menu and then select a channel to set its corresponding parameters www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Configuration System Setup Monitor Setup Dome Protocol Camera Setup CH 2 Camera Title CH3 CH4 Covert CH5 CHE CH7 Brightness 4 Dome ID zZz CH g o Termination K CH8 Record Setup Event Setup Saturation Contrast e e e e ler lab lab d Hue Audio Association Io X Cancel vf Apply Items listed in the menu are described as follows Dome Protocol The item is for selecting the communications protocol associated with your dome camera The available p
138. t up the connection Record Setup There are three factors that effect the total record time of DynaGuard 200 series unit HDD capacity recording rate Picture per Second and image quality settings The greater the recording rate and the higher the quality setting the shorter the recording time Most of the related factors can be set here in this submenu The Record Setup menu allows user to set recording quality recording schedules and other recording parameters Administrator s password is www dynacolor com tw 75 All rights reserved User s Manual 5 4 1 5 4 2 76 DYNACOLOR Ke required to use Record Setup menu In the Main menu move the cursor to lt Record Setup gt and press ENTER The following menu is displayed Record Setup 1 Record Mode 720x240 60PPS 2 Schedule Setup 3 Preset Config Standard 4 Per Camera Config 5 Event Percentage 20 6 Data Lifetime 7 Days 7 Pre Alarm Recording 15 Sec 8 Circular Recording ON 9 Audio Recording ON 10 Purge Data Record Mode The item is for selecting resolution and recording rate The relative record settings such as preset configuration will follow the record mode setting The options are 720 x 480 30PPS gt 720 x 240 60PPS gt and lt 360 x 240 120PPS gt in NTSC lt 720x576 25PPS gt lt 720x288 50PPS gt lt 360x 288 100PPS gt in PAL Move the cursor to this item and press ENTER then select a Record mode using UP DOWN buttons
139. tart import NOTE If the imported configuration has different record mode from the units the warning message This config has different record mode This will FORMAT ALL HARDDISKS will show NOTE Remove the ThumbDrive used for import configuration after the unit restarts or it will be formatted as well 5 8 3 Export Configuration The Administrator is allowed to save a unit configuration by exporting it to an external drive such as a USB Flash Drive Before exporting the configuration make sure the device in which the configuration will be saved is attached to the unit appropriately Select Export Config from the Configuration menu and press ENTER The following menu is displayed Export Config 1 Copy Destination 2 Config Name 3 Begin Export NO Items in this menu are described in the following sections 5 8 3 1 Copy Destination Select this item to list available destinations external memory devices to which the configuration can be exported Press UP DOWN to set a destination Please note that saving a different configuration to the same copy destination with the same file name will overwrite the previous configuration file without warning NOTE Users are not allowed to select any CD R W or DVD RW as a copy destination including built in CD R W and DVD RW www dynacolor com tw 91 All rights reserved User s Manual 5 8 3 2 5 8 3 3 5 9 92 DYNACOLOR Ke Configuration Name This item allows
140. te 138 inq Contas NIRE TIE 138 Monitor Geer 138 VGA ar ogee ce cage 138 539 Camera a e 138 D me Protocol Met eege 139 All rights reserved User s Manual 5 4 Record Setup 5 5 5 4 1 Schedule Setup 5 4 2 Preset Configuration 5 4 3 Per Camera Configuration 5 4 4 Event Percentage 5 45 Data LUNG eerie 5 4 6 Pre Alarm Recording 5 4 7 Circular Recording 5 4 8 Audio RECOMING DEE Event Setup Me 5 5 1 Internal Buzzer usce b babens Scene st eee eee ene ee tee eee fe 99 9 Email NOGE sisone 554 Event Duration 5 5 5 Per Channel Configuration Dome ID Camera EE eetedatecebde st et RT EE De ANON T EE Rn E Video Loss Detect eer EE Detection Configuration Alani l Alarm OUD E 6 Trouble Shooting Guide Appendix A Setting up a DVR behind a Router DYNACOLOR Ke www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual 1 Overview The DynaGuard 200 series unit is an integrated digital video recorder that combines the features of a time lapse audio video recorder a multiplexer and a video server to create a single security CCTV solution Its outstanding triplex operation enables user to view live playback recorded video and remote access through network simultaneously while recording other video and to view wanted recorded video instantly by entering the time and date or selecting
141. the total pps with a correct weighting www dynacolor com tw All rights reserved DYNACOLOR Ke 4 4 1 4 1 1 User s Manual Basic Operation The DynaGuard 200 series allows user to access some general operations through the front panel easily The following sections introduce the general operations of the unit Viewing Live Playback Video The general functions in live and playback mode are described in the following sections Viewing Modes The DynaGuard 200 series supplies user versatile ways of viewing both live and recorded video Following presents these view formats Viewing in Full Screen Press any CHANNEL button directly to view the corresponding camera image in full view format Viewing in Multi window Various multi window view formats are offered for selecting To switch between available viewing formats press MODE repeatedly The available view formats are illustrated as the following figure Full Screen Digital Zoom User can view a 2x full screen in live and playback mode To view the 2x full screen follow the steps e Press a CHANNEL button to view the corresponding camera in full screen e Press ZOOM to enter a 2x full screen zoom mode of the selected camera e f you need to view specific area of the 2x zoomed screen use Direction buttons to pan tilt the zoomed area around the original image e Either press ZOOM again or ESC to leave the zoom mode www dynacolor com
142. tion screen and apply them to the remote unit System Setup The System setup screen allows user to set language date time password and network and RS 485 settings on the remote unit Click MENU button on the main window toolbar and expand the System setup menu by clicking the plus icon The expanded System Setup menu displays as below www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual System Setup Date Time Unit Name Password Network Setup R5485 Setup Audio Output Key Beep Monitor Setup Camera Setup Record Setup Event Setup Items in the System Setup menu are described as follows 5 1 1 Language The Language item allows user to select the system language for OSD menu and screen messages Language selection takes effect immediately when the selection is done NOTE The selection only takes effect on the unit but does not affect DynaRemote language selection 5 1 2 Date Time Click Date Time to display the Date Time menu shown as follows It allows user to configure the date time related settings NOTE The Date Time Display Date Time Display Mode and Date Time Order settings only apply to the remote unit Configuration cor Date i Time 10 43 40 AM Password Date Time Display hRw sl Network Setup AS495 Setup Date Display Mode D M Y oe Time Display Mode bam sl Monitor Setup Date Time Order DateFist gt Camera Setup Record Setup Dayli
143. tor Speaker Router Ethernet Alarm Input n RI Export Audio A WEEK 2 USB Thumb Drive DH701 DH801 D7610 Other Brand IEEE 1394 CD RW High Speed Dome Fixed Camera Cameras Disk Array DVD RW www dynacolor com tw 17 All rights reserved User s Manual 2 2 1 2 2 2 3 DYNACOLOR Ke System Installation The notices and introduction on system installation will be described particularly in this chapter Please follow the description to operate the unit In order to prevent the unit from data loss and system damage that caused by a sudden power fluctuation use of an Uninterruptible Power Supply UPS is highly recommended Position the Unit Firstly note to position mount the DynaGuard 200 series unit in a proper place and be sure to power off the unit before making connections The placed location should avoid hindering or blocking the unit from airflow Enough airflow is needed to protect the unit from overheating The maximum allowable temperature of operating environment is 40 C The unit utilizes heat conducting techniques to transfer internal heat to the case especially to the bottom side of the unit NOTE Be sure not to remove the rubber feet and always leave a space for air ventilation on the unit s bottom side Selecting Video Format The DynaGuard 200 series unit is designed to operate under either NTSC or PAL video formats Please contact with a qualified service per
144. tw 35 All rights reserved User s Manual 4 1 3 4 1 4 36 DYNACOLOR Ke Viewing Live Cameras Users are allowed to view live camera in versatile view modes such as full screen 2x2 and 3x3 The general operation under live mode is described as follows Viewing in Sequence Mode Automatic sequence function can be used in any view mode Select certain view format and press SEQ to toggle the automatic sequential sequence press ESC to stop sequencing The figure below displays the 4 camera sequencing view modes To Freeze Live Image Press FREEZE while viewing live image the image pauses but the date time information does not and the system clock continues running Press FREEZE to pause the live image press FREEZE again to resume the live camera view Viewing Recorded Video To view recorded video user can press PLAY STOP button directly When press the PLAY STOP button the unit starts to continue playing back the recorded video from the suspended point of record If it is the first time to use the PLAY STOP key the unit will playback from the very beginning of the record Alternatively user can select records from the Search menu to play specific video Refer to section 4 3 Searching Recorded Video for more information The Forward or Reverse speed indicator will be shown on the bottom left of the screen when in the playback mode The general operation in playback mode is described as follows www dynaco
145. user to assign the exported configuration file a name Use the virtual keyboard to enter the configuration file name Note that the file name can contain up to 15 characters with no spaces Begin Export Select lt YES gt to begin exporting the configuration file or lt NO gt to abort the export Video Export The Video Export menu enables the administrator to export recorded video with digital signature to a USB Thumb drive a CD RW or to DVD RW drive Make sure an external storage device is available and connected to the appropriate port for video export Administrators password is required to export video If the Pre Alarm Recording function is enabled the event video will be exported into two files including pre alarm video and video recorded after the alarm is triggered Each recorded video will be exported into four files when exporting with digital signature including gpg avi drv sig and readme txt To export 1GB file with digital signature may take you about 30 minutes From the Main menu select Video Export and press ENTER The following menu is displayed Video Export 1 Select Device 2 Select Ch CH1 CH2 CH3 CH4 3 From 2005 03 19 AM 07 50 05 4 To 2005 03 28 PM 03 09 18 5 Select Events 6 Data Type Normal 7 Export Format DRV 8 Digital Signature NO 9 Erase Disc NO 10 Begin Export NO www dynacolor com tw All rights reserved DYNACOLOR Ke User s Manual Item
146. ww dynacolor com tw 53 User s Manual NOTE To avoid record database corruption after changed Date Time setting clear the database is recommended All rights reserved User s Manual 5 1 3 7 5 1 3 8 5 1 4 54 DYNACOLOR Ke If the function is disabled the DST Start End time and DST Bias will be grayed out and cannot be accessed If this function is enabled the date time information will be shown on the screen with a DST icon when playing back recorded video or searching video in the event list S indicates summer time and W indicates wintertime DST Start End The items are used to set the daylight saving duration Use LEFT RIGHT to move the cursor to the next or previous field UP DOWN to change the settings DST Bias The item allows user to set the amount of time to move forward from the standard time for daylight saving time Available options are lt 30 gt lt 60 gt lt 90 gt and lt 120 gt minutes Unit Name Users are allowed to assign a name to the DynaGuard 200 series unit Follow the steps to edit the unit name e Select Unit Name from System Setup menu and press ENTER A virtual keyboard displays Unit Name A BCD F GH iI J M N O QRS T VWXYZ a b c e f g h i j k I m n o q rs t u vw xXx y z 0 1 3 4 5 6 78 9 Wow lt gt Backspace Delete Cancel OK e Use Direction buttons to move the cursor to the wanted character www dynacolor com tw All right
Download Pdf Manuals
Related Search
Related Contents
Toshiba GD-1300 Fax Machine User Manual 1 Manual Sistema Endereçável Inteligente Fiamma Ruscool Dual Radio (Config Manual - Ver 1.0) Epson Photo 1200 Printer User Manual 取扱説明書 SupaBoy Instruction Manual v3 Miolo Abril 2014 MONTADO.p65 電気用品の取扱いについて(内規) 2013 Tacoma - Capitale Chrysler Volume 1 - Università degli studi di Pavia Copyright © All rights reserved.