Home
Instruction Manual for FrSky D8R-II plus
Contents
1. T Sk Y www frsky rc com 05 01 12 Instruction Manual for FrSky D8R II plus 1 Introduction 1 1 Compatibility Compatible with FrSky two way telemetry modules DFT DJT DHT DHT U 1 2 Specifications Dimension 55 25 14mm Weight 12 4g SAY A Operating Voltage Range 3 5V 10 0V s DSR Iri Operating Current 100mA Operating Range full range gt 1 5km Servo Frame Rate 18ms FS Normal Speed Mode 9ms HS High Speed Mode 1 Two external analog telemetry ports A1 amp A2 and one digital data stream port Rx 2 When side port pins of A1 and X are connected by the jumper A1 will change from external analog telemetry port to internal built in battery voltage sensor 3 Convenient to upgrade no need to open the receiver s case when upgrade D8R II plus 4 Two switchable PPM modes FS mode and HS mode 5 Alarm warning on low voltage poor reception etc ACLST Telemetry 1 3 Features 2 Setup 2 1 Bind procedure 1 Ascertain that the transmitter is in the PPM mode Turn off the transmitter 2 Turn on the transmitter while holding the F S button on the transmitter module Ensure that both switches on the transmitter module are OFF when using D8R II plus in two way mode Release the button The RED LED on the transmitter module will flash indicating the transmitter is ready to bind to the receiver 3 Connect battery to the receiver while holding the F S button on the receiver The RED LED on t
2. e F S button of the transmitter module for 1S 4S to exit range check mode RED LED will be back on indicating normal operation is back 2 3 Setting failsafe Failsafe is a useful feature in which all controls move to a preset position whenever the control signal is lost for a period of time D8R II plus supports failsafe function for all channels gt F r Sk Y www frsky rc com 05 01 12 Follow the steps below to set failsafe positions for each channel 1 Bind the receiver first and turn on both the transmitter and the receiver 2 Move the controls to the desired failsafe position for all channels 3 Press briefly the F S button on the receiver less than 1 second The transmitter module will make a long beep indicating the failsafe position has been set in the receiver To disable the failsafe function re bind the receiver Failsafe is recommended to set when system is firstly used or receiver has been re bound Follow steps below to set failsafe Option 1 How to set failsafe to a user determined state on lost signal 1 Bind the receiver to the transmitter module first and turn on both the transmitter and the receiver 2 Move the controls to desired failsafe position for all channels 3 Press briefly the F S button on the receiver and you are done Option 2 How to set failsafe for no pulses on lost signal 1 Just press briefly the F S button on the receiver while the transmitter is off and you are done Note If fai
3. he receiver will flash indicating the binding process is completed Turn off both the transmitter and the receiver 4 Turn on the transmitter and connect the battery to the receiver The RED LED on the receiver will indicate the receiver is receiving commands from the transmitter The receiver transmitter module binding will not have to be repeated unless one of the two is replaced 2 2 Range check A pre flight range check should be done before each flying session Reflections from nearby metal fences concrete buildings or trees can cause loss of signal both during range check and during the flight The following steps are to be followed to perform the range check of the model before the flight 1 Place the model at least 60cm two feet above non metal contaminated ground e g on a wooden bench 2 The receiver antennas should be separated in the model and do not touch the ground 3 Place the antenna of the transmitter in a vertical position 4 Turn on the transmitter and the receiver press the F S button of the transmitter module for 4 seconds to enter range check mode the RED LED of the transmitter module will be off GREEN LED will flash rapidly and the beeper will sound The effective distance will be decreased to 1 30 of full range 5 Walk away from the model while simultaneously operating the controls on the transmitter confirming that all controls operate normally to a distance of at least 30 meters 30 yds 6 Press th
4. lsafe is not set failsafe default will hold last position before signal is lost In this case there exists risk that your model will fly away or cause injury 2 4 LED status O imty On NomaOperation 2 5 Pins definition for side ports It should be noted that 3 3V only has a limited driving current 1 10mA it should not be used for driving a MPU 2 5 1 Two external analog telemetry ports A1 amp A2 and one digital data stream port Rx Rx input to receiver RS232 level connect with FrSky sensor hub A2 external max voltage 3 3V division ratio 1 1 A1 external max voltage 3 3V division ratio 1 1 2 5 2 When side port pins of A1 and X are connected by the jumper A1 will change from external analog telemetry port to internal built in battery voltage sensor Rx input to receiver RS232 level connect with FrSky sensor hub A2 external max voltage 3 3V division ratio 1 1 A1 internal max voltage 3 3V division ratio 4 1 3 How to switch between two PPM modes Turn the transmitter off connect the battery to the receiver press the F S button of the receiver for 6 seconds and then release The red LED will flash fast in HS mode and slowly in FS mode The mode alternates each time this procedure is done
Download Pdf Manuals
Related Search
Related Contents
ICC IC107F3CWH Dayton® Hazardous Location Direct warning - Jacobsen Origin Storage 320GB Website CyM Distributor (WebCyM) Vista Previa - Oficina Virtual Manual de Instalación de LibreOffice para Windows y Linux usps gats informal payments educational user guide 全文 - 裁判所 LBF 462 Bedienungsanleitung/Garantie Stereo-Funk Copyright © All rights reserved.
Failed to retrieve file