LA35 ACTUATOR
Contents
1. 24VDC 10 2 x AWG14 Current consumption 12V 2 10A depending on load 24V 1 5A depending on load See curves for typical values Speed regulations The motor can run with PWM regulation This could be used for soft start stop etc The version with C option cannot be operated with PWN Connection To extend actuator Connect Brown to positive Connect Blue to negative To retract actuator Connect Brown to negative Connect Blue to positive See figure 1 24344 Use cable 0367002 XXXX Actuator direction can be operated with double throw switch with middle position off LINAK Code TR 1939 3314 00 1 O Specifications Potential free signal switches Item Specification Comment Description The actuator can be equipped with two separate micro switches that that are activated when the actuator is fully retracted IN or fully extended 0oUT OUT The micro switches are Normally Open Input Voltage 10 28VDC Cable dimension 6 x 0 5mm 6 x ANG20 Output voltage Same as input voltage Switching capacity Minimum 10 mA Maximum 1 A Connection Supply Red Pin 2 Actuator retracted Yellow Pin 5 Actuator extended Green Pin 6 See figure 2 3 4 Use cable 0367003 XXXX Combinations The potential free switches can be combined with relative or absolute feedback But cannot be combined with C option 3530000 1 XXXXXX Pa
2. 886 2 27290068 Fax 886 2 27290096 Mobile 886 989292100 E mail michael chen linak com tw www linak com tw TURKEY LINAK ith ihr San ve Tic A S Phone 90 312 4726338 Fac 903124726635 E mail info linak com tr www linak com tr UNITED KINGDOM LINAK UK Limited Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk The user is responsible for determining the suitability of LINAK products for specific application LINAK takes great care in providing accurate and up to date information on its products However due to continuous development in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarantee the correct and actual status of said information on its products While LINAK uses its best efforts to fulfil orders LINAK cannot for the same reasons as mentioned above guarantee the availability of any particular product Therefore LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK All sales are subject to the Standard Terms of Sale and Delivery for LINAK For a copy hereof please contact LINAK LINAK MA M9 02 246 E LINAK A S reserves the right to make technical alterations Copyright LINAK 2014 09 WE IMPROVE YOUR LIFE
3. 27 11315 6999 E mail gartht isagroup co za www isaza co za UNITED ARAB EMIRATES Mechatronics Phone 971 4 267 4311 Fax 971 4 267 4312 E mail mechtron emirates net ae www mechatronics ae Page 20 of 20 USA LINAK U S Inc North and South American Headquarters Phone 1 502 253 5595 Fax 15022535596 E mail info linak us com www linak us com NORWAY LINAK Norge AS Phone 47 32 82 90 90 Fax 47 32 82 90 98 E mail info linak no www linak no POLAND LINAK Polska Phone 48 22 500 28 74 Fax 48 22 500 28 75 E mail dkreh linak dk www linak pl REPUBLIC OF KOREA LINAK Korea Ltd Phone 82 0 2 6231 1515 Fax 82 0 2 6231 1516 E mail scully linak kr www linak kr RUSSIAN FEDERATION 000 LINAK Phone 7 495 280 14 26 Fax 74956871426 E mail info linak ru www linak ru SPAIN LINAK Actuadores S L u Phone 434 93 588 27 77 Fax 34 93 588 27 85 E mail linakact linak es www linak es For contact details on other countries please visit www or contact LINAK INTERNATIONAL Phone 45 73 15 15 15 Fax 45 74 45 90 10 Fax 45 73 15 16 13 Sales E mail info linak com www linak com Terms of use SWEDEN LINAK Scandinavia AB Phone 46 8 732 20 00 Fac 468 7322050 E mail info linak se www linak se SWITZERLAND LINAK AG Phone 41 43 388 31 88 Fax 41433883187 E mail info linak ch www linak ch TAIWAN LINAK A S Taiwan Representative Office Phone
4. O Specifications Absolute positioning Item Specification Comment Description The actuator can be equipped with electronic circuit that gives an analog SIGNAL feedback signal when the actuator moves Input Voltage 11 28 V DC Feedback circuit to be powered 1 second before motor runs and until 1 second after the motor has stopped Cable dimension 6 x 0 5 mm 6 x AWG20 Output voltage 0 10V 0 5V Max current output 1mA Current consumption Current consumption is max 40 mA Also when actuator is not running Connection Supply White Pin 3 Ground Black Pin 1 Signal Violet Pin 4 See figure 4 Use cable 0367003 XXXX Combinations The Absolute positioning can be combined with potential free Switches But cannot be combined with relative positioning 3 5XXXXXXAXXXXX Page 13 of 20 I O Specifications IC option Item Specification Comment Description Easy to use interface with See figure 5 integrated power electronics Hbridge Em 6 for direct PLC connection Soft start of the actuator tenw Power supply Input Voltage 12 V DC 20 24 V DC 10 Cable dimension 2 x 2 5 mm 2 x AWG14 Current consumption 12 V 2 10 A depending on load 24 V 1 5 A depending on load Recommended fuse 12V version 20A fuse 24V version 10A fuse Inputs Signals to the A
5. the equipment is not in use Switch off the mains supply or pull out the plug in order to prevent unintentional operation Check regularly the actuator and joints for extraordinary wear Reinstall always the cabellock and a tight screw with 1 5 Nm 20 Classification The equipment is not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide Important information Information about the actuators is described under the following two headings Warning Failing to follow these instructions can cause accidents resulting in serious personal injury 2 Failing to follow these instructions can result in the actuator suffering damage or being ruined Page 5 of 20 DECLARATION OF CONFORMITY LINAK A S Smedeveenget 8 DK 6430 Nordborg hereby declares that LINAK Actuator 35xxxxxxxxxxx2x complies with the EMC Directive 2004 108 EC according to following harmonized standards EN 61000 4 2 1995 A1 A2 EN 61000 4 3 2006 EN 61000 4 4 2004 EN 61000 4 5 1995 A1 EN 61000 4 6 1996 A1 EN 50121 3 2 EN 60204 31 1999 Additional information The actuator does also comply with EMC parts of The Machinery Directive 2006 42 EC The Recreational Craft Directive 94 25 EC The Vehicle EMC Directive 2004 104 EC and complies with the following standards DS EN 13309 2001 Construction machinery Electromagnetic compatibility of machines with internal electrical power supply DS EN ISO 14
6. 982 1998 Agricultural and forestry machines Electromagnetic compatibility Test methods and acceptance criteria and EN ISO 13766 2006 Earth moving machinery Electromagnetic compatibility Date 2009 04 16 Signature 2 John Kling Page 6 of 20 Misc on the TECHLINE actuator system Warranty There is a 18 months warranty on the TECHLINE products against manufacturing faults calculated from the production date of the individual products see label LINAK s warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with Furthermore the actuator must not be exposed to violent treatment In the event of this the warranty will be ineffective invalid For further details please see LINAK A S ordinary conditions of sale Maintenance The actuator must be cleaned at regular intervals to remove dust and dirt and inspected for mechanical damages or wear Inspect attachment points wires piston rod cabinet and plug as well as check that the actuator functions correctly The actuator is a closed unit and requires no internal maintenance To ensure that the pregreased inner tube remains lubricated the actuator must only be washed down when the piston rod is fully retracted Maintenance of spherical eyes In order to maintain a prober performance of the spherical eyes and to increase the resistances against hard environmental wear we strongly recomme
7. D TECHLINE IMPROVING FLEXIBILITY LA35 ACTUATOR LI NAK To learn more about LINAK please visit WWW LINAK COM WE IMPROVE YOUR LIFE Page 1 of 20 Page 2 of 20 Contents c 4 M 5 Important IMTORMATION RR ERAN US KI A Re RAE AMI UC Nu OE ced 5 Declarations of Conformity erigat regne ge eR Rc Ra a RR NAR 6 Misc on the TECHLINE actuator system Warranty Maintenance Maintenance of spherical eyes Specifications Mounting guidelines 00 NNN Applications hints Electrical installation Motor connection 10 Connection diagrams 10 Specifications Motor 12 Specifications Potential free signal switches 12 I O Specifications Relative positioning 13 Specifications Absolute positioning 13 Connection of the LA35 with the CS16 15 Troubleshooting 15 Mounting of cables 5 eren Hace ilte ORARE RE rure a ERE HET ke nanus PII M M Drawings dimensions Main groups of disposal 18 Label for LA35 18 TS OS ias rtt eee esd cance e enr pU rt HH AM E a P NUM DM dan M uU e rH EM UEM E M EE 20 Page 3 of 20 Preface We are delighted that you have c
8. Supplies www ballind com au BL Shipways amp Co www blshipway com au Gas Strut Marine and Industrial www gasstrutmarine com au Prime Motion amp Control www primehyd com au West Vic Industrial Supplies www westvicindustria com au COLOMBIA MEM Ltda Phone 57 1 334 7666 Fax 57 1 282 1684 E mail servicioalcliente memltda com co www memltda com co INDONESIA Pt Himalaya Everest Jaya Phone 6 221 544 8956 6 221 544 8965 6 221 619 4658 6 221619 1925 E mail hejplastic div centrin net id www hej co id Fax DENMARK LINAK A S Group Headquarters Guderup Phone 45 73 15 15 15 Fac 45 74 45 80 48 Fac 45 73 15 16 13 Sales E mail infoGlinak com www linak com DENMARK LINAK Danmark A S Phone 445 86 80 36 11 Fax 45 86 82 90 51 E mail linak linak silkeborg dk www linak dk FINLAND LINAK OY Phone 358 10 841 8700 Fax 358108418729 E mail linakGlinak fi www linak fi FRANCE LINAK France E U R L Phone 433 0 2 41 36 34 34 Fax 33 0 2 41 36 35 00 E mail linak linak fr www linak fr GERMANY LINAK GmbH Phone 49 6043 9655 0 Fax 496043965560 E mail info linak de www linak de INDIA LINAK A S India Liaison Office Phone 491 120 4393335 Fax 91 120 4273708 E mail info linak in www linak in IRELAND LINAK UK Limited Ireland Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 44 0 796 855 1606 UK Mobile SLOVAKIA LINAK Slovakia s r
9. ctuator Outwards direction Extends the Actuator FW Red Pin 2 PNP Output Red Power supply Inwards direction Retracts the Actuator BW Black Pin 1 PNP Output Black Power supply On Off voltages On voltage High Examples on 24 V version 67 96 of the power supply On if the voltage is higher than 16 V Off voltage Low 33 96 of the power supply Off if the voltage is lower than 8 V Input Impedance 10 K ohm Input current 10mA Outputs Signals from A ctuator Actuator fully Signal when end stop switch in retracted Max 50 mA switching capacity retracted IN position is activated IN Yellow Pin 5 High Actuator fully Signal when end stop switch in extended Max 50 mA switching capacity extended OUT position is activated OUT Green Pin 6 High Actuator ready When the Actuator is ready the signal Max 10 mA switching capacity is High Ready White Pin 3 Current cut off Current cut off 12 V version 17 21 A Current cut off 24 V version 8 5 10 5 A Output voltage Typical Input voltage 1 V Example on 24 V version Output voltage on IN 23 V 4 0 5V Output voltage on OUT 23 V 4 0 5V Output voltage on READY 23 V 0 5V Relative For functional description see I O Max 12mA switching capacity positioning Specifications for Relative T positioning SIGNAL 35 2 Absolute For functional descript
10. failure See Figure 2 Make sure the mounting pins are supported in both ends Failure to do so could shorten the life of the actuator Cantilever mounts are unacceptable RIGHT WRONG Figure 1 Figure 2 Warning If the actuator is used for pull in an application where personal injury can occur the following is valid It is the application manufacturer s responsibility to incorporate a suitable safety arrangement which will prevent personal injury from occurring if the actuator should fail Warning LINAK s actuators are not constructed for use within the following fields Offshore installations Aeroplanes and other aircraft Explosive environments Nuclear power generation Application hints The actuator is weatherproof for use in outdoor applications The actuator can be washed down with a high pressure washer but it should not be used under water The duty cycle at max load is 1096 on time This means if the actuator runs continuously for 2 minutes it must remain off for 18 minutes before operating again Page 9 of 20 Electrical installation Be aware of BUS actuator please see the installation guide Motor connection Wiring The actuator direction forward reverse is controlled with a doublethrow switch with the centre postion off Actuation To extend the actuator connect brown to po
11. ge 12 of 20 Specifications Relative positioning Item Specification Comment Description The actuator can be equipped with a hall sensor and a spindle magnet In this way SIGNAL you can have pulses from the actuator when it moves The output signal is a PNP signal Input Voltage 10 28 V DC Feedback circuit to be powered 1second before motor runs and until 1 second after the motor has stopped Cable dimension 6 x 0 5 mm 6 x AWG20 Output voltage Same as input voltage Typical Output voltage HIGH Output Input 1V 0 5V LOW Output 0 0 5V Current consumption Current consumption is max 40 mA Also when actuator is not running Switching capacity 100 mA max Ground Black Pin 1 Signal Violet Pin 4 Resolution The feedback system gives 8 pulses per Pulse pause minimum 10 Milliseconds spindle turn On 100 mm stroke you will have the fol 3 mm pitch 0 38 mm per pulse lowing number of pulses 5 mm pitch 0 63 mm per pulse 3 mm pitch 266 pulses 9 mm pitch 1 13 mm per pulse 5 mm pitch 160 pulses 12 mm pitch 1 5 mm per pulse 9 mm pitch 88 pulses 12 mm pitch 66 pulses Connection Supply White Pin 3 See figure 3 Use cable 0367003 XXXX OV Fully retracted 10V Fully extended Combinations The Relative positioning can be combined 35xxxxxxHXxxxxx with potential free Switches But cannot be combined with absolute positioning I
12. gs e Plug in the power cable and or the signal cable Slide the cover onto the actuator The torque of the cover screw is app 4 Nm Note When changing the cables on a LINAK actuator it is important that this is done carefully in 0059 order to protect the plugs and pins Please be sure that the plug is in the right location and fully pressed in before the cable lid is mounted Accessories Cables Power cables Ordered separately Order no 1 5 m cable 0367002 1500 5m 0367002 5000 0 2 m cable AMP connectors 0367006 Signal cable Ordered separately Order no 1 5 m cable 0367003 1500 5m 0367003 5000 Be aware for BUS actuator please see the installation guide Page 16 of 20 DRAWING APPENDIX TECHLINE LA35 LA35 10 2 8 Installation dimension STROKE lt 300 200 STROKE STROKE gt 300 250 STROKE Minimum Installation dimension 300 mm EN ett ee ener e Page 17 of 20 Main groups of disposal Product Metal scrap Cable scrap Electronic scrap Plastic recycling or combustion LA35 X X X X LINAK s products may be disposed of possibly by dividing them into different waste groups for recycling or combustion We recommend that our product is disassembled as much as possible at the disposal a
13. hosen a product from LINAK LINAK systems are high tech products based on many years of experience in the manufacture and development of actuators electronic control boxes controls and chargers We are also constantly improving our products to meet customer requirements This user manual will tell you how to install use and maintain your LINAK LA35 actuator We are sure that the LA35 actuator will give you a problemfree operation Before our products leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK products you are always welcome to contact our service departments or service centres Most LINAK subsidiaries have authorised service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is subject to correct use in accordance with the specifications maintenance being done correctly and any repairs being carried out at a service centre which is authorised to repair LINAK products LINAK A S Page 4 of 20 Safety instructions A Please read the following safety information carefully Ensure that all staff who are to connect mount or use the actuator are in possession of the necessary information and that they have access to this user manual Persons who do not have the necessary experience or knowledge of the product products must not use the product products Besides persons with reduced physical or me
14. ion see I O positioning Specifications for Absolute SIGNAL 35300002 AXXXXX positioning Connection See figure 5 Use cables 0367002 XXXX and 0367003 XXXX Page 14 of 20 Connection of the LA35 with the CS16 R RED ORANGE GR GREEN Troubleshooting Symptom Possible cause Action No motor sound or movement of piston rod The actuator is not connected to the power supply Cable damaged Connect the actuator to the power supply Change cable Send actuator for repair Excessive electricity consumption Misalignment or overload in application Align or reduce load Send actuator for repair Motor runs but spindle does not move Gearwheel or spindle damaged Send actuator for repair Actuator cannot lift full load Clutch is worn Motor is damaged Send actuator for repair No signal from potentiometer or hall effect sensor Cable damaged Potentiometer damaged Change cable Send actuator for repair Motor runs too slowly or does not give full force Insufficient power supply Voltage drop in cable ncrease power supply Thicker cable Actuator cannot hold the chosen load Load is higher than specified Reduce load Be aware of BUS actuator please see the installation guide Page 15 of 20 Mounting of cables e Unscrew the cover and remove the two blind plu
15. nd that the spherical ball bearings eyes mounted on actuators from LINAK are greased with anticorrosive grease or similar Warning If irregularities are observed the actuator must be replaced Page 7 of 20 Specifications Motor Cable Housing Spindle part Temperature range End play Weather protection Permanent magnet motor 12 or 24 Motor 2 x 14 AWG PVC cable Control 6 x 20 AWG PVC cable The housing is made of casted aluminium coated for outdoor out and in harsh conditions Outer tube Powder coated steel Inner tube Stainless steel 51304 552333 Acme spindle Trapezoidal spindle with high efficiency 10 C to 50 C Full performance 5 to 40 2 mm maximum Rated IP66 for outdoor use Furthermore the actuator can be washed down with a high pressure washer BUS actuators only 24V please see the installation guide Special control cabels for BUS actuator please see the installation guide Page 8 of 20 Mounting guidelines LINAK linear actuators are quickly and easily mounted by slipping pins through the holes on each end of the units and into brackets on the machine frame and the load The mounting pins must be parallel to each other as shown in Figure 7 Pins which are not parallel to each other may cause the actuator to bend and be damaged The load should act along the stroke axis of the actuator since off centre loads may cause bending and lead to premature
16. nd that you try to recycle it As examples of main groups within sorting of waste we can mention the following Metal scrap Plastic scrap Cable scrap Combustible material and collection for recoverable resources Some of these main groups can be sub divided into groups e g metal can be divided into steel and aluminium or plastic can be divided into ABS and PP Label for LA35 LINAK G WE IMPROVE YOUR LIFE Mem No 354041 00200821 Prod Date 2008 02 08 5 0 6002412 sh 1000 N IP66 Mas Lond Push 4 Poner Rata 24 V Max 28 Amp Max 2 min in ow 1 MADE BY LINAK A S DENMARK Page 18 of 20 LINAK APPLICATION POLICY The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware software technical advice etc related to an existing or new customer ap plication LINAK products as defined above are applicable for a wide range of applications within the Medical Fur niture Desk and Industry areas Yet LINAK cannot know all the conditions under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions ap plication vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK pr
17. ntal abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product Before you start mounting dismounting ensure that the following points are observed The actuator is not in operation The mains current supply is switched off and the plug has been pulled out The actuator is free from loads that could be released during this work Before you put the actuator into operation check the following The actuator is correctly mounted as indicated in the relevant user instructions The equipment can be freely moved over the actuator s whole working area The actuator is connected to a mains electricity supply transformer with the correct voltage and which is dimensioned and adapted to the actuator in question Ensure that the voltage applied matches to the voltage specified on the actuator label Ensure that the connection bolts can withstand the wear Ensure that the connection bolts are secured safely During operation Listen for unusual sounds and watch out for uneven running Stop the actuator immediately if anything unusual is observed Do not sideload the actuator Use only the actuator within the specified working limits Do not step or kick on the actuator When
18. o Phone 421 51 75 63 414 Fax 421 51 75 63 410 E mail jp linak sk www linak com ITALY LINAK Italia S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail infoGlinak it www linak it JAPAN LINAK K K Phone 81 45 533 0802 Fax 81 45 533 0803 E mail linak linak jp www linak jp MALAYSIA LINAK Actuators Sdn Bhd Phone 60 4 210 6500 Fax 60 4 226 8901 E mail info linak asia com www linak my NETHERLANDS LINAK Actuator Systems B V Phone 3176 5 42 44 40 Fax 31 76 5 42 61 10 E mail info linak nl www linak nl NEW ZEALAND LINAK New Zealand Ltd Phone 64 9580 2071 Fax 64 9580 2072 E mail nzsales linak com au www linak co nz 35 387 634 6554 Republic Of Ireland Mobile E mail sales linak co uk www linak co uk IRAN Bod Inc Phone 98 2188998635 6 Fax 982188954481 E mail info bod ir www bod ir MEXICO ILSA S A de C V Phone 52 55 5388 3960 Fax 52 55 5388 3966 E mail linak ilsamexico com www ilsamexico com PERU Percy Martin Del Aguila Ubillus Phone 51 99 883 9879 RUSSIAN FEDERATION 000 FAM Phone 47 812 3319333 Fac 478123271454 E mail purchase fam drive ru www fam drive ru SINGAPORE Servo Dynamics Pte Ltd Phone 65 6844 0288 Fax 65 6844 0070 E mail servodynamics servo com sg www servo com sg SOUTH AFRICA Industrial Specialised Applications CC Phone 27 11 312 2292 or 27 11 2077600 Switch Board Fax
19. oduct LINAK shall be responsible solely that the LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question Page 19 of 20 FACTORIES CHINA LINAK Shenzhen Actuator Systems Ltd Phone 86 755 8610 6656 Fax 86 755 8610 6990 E mail sales linak cn www linak cn SUBSIDIARIES AUSTRALIA LINAK Australia Pty Ltd Phone 61 3 8796 9777 Fac 613 8796 9778 E mail sales linak com au www linak com au AUSTRIA LINAK Reprasentanz sterreich Wien Phone 43 1 890 7446 Fax 43 1 890 744615 E mail info linak de www linak at BELGIUM amp LUXEMBOURG LINAK Actuator Systems NV SA Phone 32 0 9 230 01 09 Fax 32 0 9 230 88 80 E mail info linak be www linak be BRAZIL LINAK Do Brasil Com rcio De Atuadores Ltda Phone 55 11 2832 7070 Fax 55 11 2832 7060 E mail infoGlinak com br www linak com br CANADA LINAK Canada Inc Phone 1 502 253 5595 Fac 1 416 255 7720 E mail info linak ca www linak us com CZECH REPUBLIC LINAK C amp S S R O Phone 420581741814 Fax 420581702452 E mail ponizil linak cz www linak cz DISTRIBUTORS ARGENTINA Novotec Argentina SRL Phone 54 11 4303 8900 54 11 4303 8989 Fax 54 11 4032 0184 E mail info novotecargentina com www novotecargentina com AUSTRALIA Ballarat Industrial
20. sitive and blue to negative To retract the actuator connect blue to positive and brown to negative Connection diagrams Basic actuator Fig 1 35 ooxx00 oooxx Actuator with potential free switches Fig 2 35 10 BLUE RED YELLOW Page 10 of 20 Actuator with potential free switches and relative positioning Fig 3 35 amp 35 1 BROWN BLUE RED YELLOW GREEN I IN bon O SIGNALS T VIOLET BLACK Actuator with potential free switches and absolute positioning Fig 4 35 amp 35 1 YELLOW GREEN WHITE EC T VIOLET BLACK Actuator with IC option Fig 5 35 20 amp 35 2 amp 35 2 BROWN M BLUE l2 24V DC OUTPUT INWARDS EL e oumas YELLOW ENDSTOP IN L___GREEN_ ENDSTOP OUT Lus gt READY VIOLET DIGITAL ANALOG INPUT Specifications Motor Item Specification Comment Description Permanent magnet DC motor available in 12V or 24V Input Voltage 12VDC 20 Cable dimension 2 x 2 5
Download Pdf Manuals
Related Search
Related Contents
Ansmann Basic 5 Plus Mode d`emploi FC116U - Virutex US3-2PEXS 取扱説明書 TBQG855B-1138-01-English Manual Benq PB2240 2000ANSI 2000:1 XGA Svideo Composite 1.9kgBrightness : 2000 Réforme des retraites 2010 Mode d`emploi pour les agents de Panas。ni膚 取扱説明 書 保管用 Renesas PCA7450SP User's Manual Copyright © All rights reserved.