1. Enable DHCP FQDN Option 47 7 Setup Mode Channel Configuration 48 Channel 1 Option 1 48 Baudrate 48 I F Interface Mode 50 RS 232 50 RS 485 2 Wire and RS 422 4 Wire 50 Flow 51 Port Number 51 Connect Mode 52 a Incoming Connection 53 b Response 53 c Active Startup 53 d Datagram Type 56 e Modem Mode 56 Send the Escape Sequence in Modem Mode 58 Show IP addr after RING 59 Auto Increment Source Port 59 Remote IP Address 59 Remote Port 59 DisConnMode 60 Flush Mode Buffer Flushing 61 Pack Control 61 Packing Interval 62 Trailing Characters 62 Send Characters 62 DisConnTime Inactivity Timeout 63 Send Characters 63 Telnet Terminal Type 63 Channel Port Password 63 8 Setup Mode Advanced Settings 64 Email Settings Option 3 64 Mail Server 65 Unit Name 65 Domain Name 65 XPort Device Server User Guide 6 Table of Contents Recipient 1 66 Recipient 2 66 Trigger 1 66 Trigger 2 67 Trigger 3 67 Expert Settings Option 5 67 TCP Keepalive time in seconds 68 ARP Cache Timeout in Seconds 68 CPU Performance 68 Disable Monitor Mode at bootup 69 HTTP Port Number 69 SMTP Port Number 69 RS 485 TX Enable Active Level 69 MTU Size 69 TCP Re transmission Timeout 70 Enable alternate MAC 70 Ethernet Connection Type 70 Security Setti
2. Modem Responses Only Full Verbose The unit does not echo modem commands and responds to a command with a message string shown in the table below Numeric Response The unit does not echo modem commands and responds to a command with a numeric response Table 7 8 Modem Mode Messages Full Verbose XPort Device Server User Guide 56 7 133BSetup Mode Channel Configuration OK Command was executed without error CONNECT A network connection has been established NO CARRIER A network connection has been closed RING n n n n Ee device having IP address n n n n is connecting to this C TT TUTUTT ee Received commands must begin with the two character sequence AT and be terminated with a carriage return character The unit ignores any character sequence received not starting with AT and only recognizes and processes single AT style commands The unit treats compound AT commands as unrecognized commands If the Full Verbose option is in effect the unit responds to an unrecognized command string that is otherwise formatted correctly begins with AT and ends with carriage return with the OK message and takes no further action If the Numeric Response option is in effect the unit responds to an unrecognized command string that is otherwise formatted correctly with the OK message and takes no further action When an active connection is in effect the unit transfers data and does not process commands receiv
3. This setting only applies if one of the configurable pins for the R8485 TXEN functionality is selected For the RS 485 interface mode to operate correctly configure one of the configurable pins to R8485 TXEN To change the configurable pins settings use Devicelnstaller or send setup records to port 77FE MTU Size The Maximum Transmission Unit MTU is the largest physical packet size a network can transmit for TCP and UDP Enter between 512 and 1400 bytes The default is 1400 bytes MTU Size 512 1400 1400 XPort Device Server User Guide 69 8 Setup Mode Advanced Settings TCP Re transmission Timeout This feature allows the configuration of the desired TCP re transmission timeout value If the ACK is not received for a packet sent from the XPort device then the unit will retransmit the data The valid range is 500 4000 msec TCP Re transmission Timeout 500 4000 ms 500 Enable alternate MAC If necessary enable the alternate MAC address if specified in the OEM setup record Enable alternate MAC N _ Ethernet Connection Type The XPort module allows for the Ethernet speed and duplex to be manually configured Enter 0 for auto negotiation default To select the speed and duplex enter one of the following 2 10 megabit half duplex 3 10 megabit full duplex 4 100 megabit half duplex or 5 100 megabit full duplex Ethernet connection ty
4. Server IP Address Enter the IP address of the mail server Server Port Enter the port number on the email server Domain Name Enter the email server s domain name Unit Name Enter the user name used by the XPort unit to send email XPort Device Server User Guide 35 4 Configuration Using Web Manager messages Spaces are not permitted Recipients Recipient 1 Email Address Enter the email address designated to receive email notifications Recipient 2 Email Address Enter an additional email address designated to receive email notifications 3 When you are finished click the OK button 4 On the main menu click Apply Settings Trigger Configuration A trigger event occurs when the unit receives the specified trigger input resulting from a specified combination of conditions on the configurable pins Set the configurable pins to Active Inactive or None The configurable pins are disabled if they are all set to None If both the serial sequence and the configurable pins are disabled the trigger is disabled To configure the XPort module s email trigger settings 1 On the main menu click Trigger 1 Trigger 2 or Trigger 3 to configure the desired trigger settings The Email Trigger Settings page opens Figure 4 10 Email Trigger Settings Email Trigger Settings Trigger 1 Conditions Configurable Pins Serial Trigger Trigger Input 1 None vj C Enable
5. CPU Performance Regular Disable Monitor Mode bootup No RS485 tx enable Active low HTTP Port Number 80 1 65535 SMTP Port Number 25 1 655535 MTU Size 512 1400 0 resulting in an operational value of 1400 TCP Re transmission Timeout 500 4000 500 ms Enable alternate MAC No OEM use only Ethernet connection type 0 resulting in auto negotiation TCP Keepalive time in seconds This option allows you to change how many seconds the unit waits during a silent connection before attempting to see if the currently connected network device is still on the network If the unit gets no response it drops that connection TCP Keepalive time in s 1s 65s Os disable 45 ARP Cache Timeout in Seconds Whenever the unit communicates with another device on the network it adds an entry into its ARP table The ARP Cache timeout option allows you to define how many seconds 1 600 the unit will wait before timing out this table ARP Cache timeout in s 1s 600s 600 CPU Performance This option allows you to increase the CPU performance required to use the higher baud rates on the serial interface 460800 bps and 921600 bps The standard CPU performance mode supports up to 230400 bps CPU performance 0 Regular 1 Low 2 High 0 Notes Ifa baud rate of 460 Kbps or 920 Kbps is set and the high performance mode is disabled the operation of the serial channel would be out of the specified
6. With Active Connect With Passive Connect At Time of Disconnect Idle Gap Time Match 2 Byte Sequence Baud Rate 9600 C Enable Packing 2msec v Yes No Send Frame Immediate Yes No ooo ono Send Trailing Bytes None One Two Hex Flush Output Buffer Owes S No With Active Connect O Yes 9 No Owes No With Passive Connect O Yes 9 No Owes No At Time of Disconnect O Yes 9 No Data Bits 8 v Parity None Stop Bits 1 v 2 Inthe available fields enter the following information Channel 1 Disable Serial Port Available on Channel 2 settings only When selected disables communication through the serial port Port Settings Protocol From the drop down menu select the protocol type for the selected channel Flow Control Flow control manages data flow between devices in a network to ensure it is processed efficiently Too much data arriving before a device is prepared to manage it causes lost or retransmitted data None is the default Baud Rate The unit and attached serial device such as a modem must agree on a speed or baud rate to use for the serial connection Valid baud rates are 300 600 1200 2400 4800 9600 default 19200 38400 57600 115200 230400 460800 or XPort Device Server User Guide 28 4 Configuration Using Web Manager 921600 Note Baud rates 460800 and 921600 are available for selection only when
7. gt GPIOO 1 bit 1 is 0 gt GPIO1 0 bit 2 is 1 gt GPIO2 1 The other bits are ignored because there are only three configurable pins on the XPort module XPort amp Device Server User Guide 81 10 Firmware Upgrades Obtaining Firmware You can obtain the most up to date firmware and release notes for the unit from the Lantronix web site www lantronix com support downloads or by using anonymous FTP ftp lantronix com pub Reloading Firmware Note For details on upgrading to version 6 1 0 0 or higher from pre 6 1 0 0 see the XPort module Upgrade Notice on the Lantronix ftp site ftp lantronix com There are several ways to update the unit s internal operational code ROM using Devicelnstaller the preferred way using TFTP or using the serial port You can also update the unit s internal Web interface COB using TFTP or Devicelnstaller Here are typical names for those files Check the Lantronix web site for the latest versions and release notes Table 10 1 Firmware Files xpt05_61000 rom xpt_webm_2005 cob Please refer to the Devicelnstaller online Help for information about reloading firmware using Devicelnstaller The other methods are discussed below Using TFTP Graphical User Interface To download new firmware from a computer 1 Use a TFTP client to put a binary file to the unit ROM to upgrade the unit s internal operational code and COB to upgrade its internal web interface
8. 9999 and do not press Enter quickly the device server reboots causing it to lose the IP address You did not press Enter quickly enough You only have 5 seconds to press Enter before the connection is closed You may have entered the Ethernet address incorrectly with the ARP command Have someone from your IT department log you in with sufficient rights Telnet back to Port 1 Wait for it to fail then Telnet to port 9999 again Make sure you press Enter quickly Telnet to port 9999 again but press Enter as soon as you see the Press Enter to go into Setup Mode message Confirm that the Ethernet address that you entered with the ARP command is correct The Ethernet address may only include numbers 0 9 and letters A F In Windows and usually in Unix the segments of the Ethernet address are separated by dashes In some forms of Unix the Ethernet address is segmented with colons XPort amp Device Server User Guide 88 When you try to assign an IP with Devicelnstaller you get the following No response from device Verify the IP Hardware Address and Network Class Please try again The device server is not communicating with the serial device to which it is attached When you try to enter the setup mode on the device server using the serial port you get no response You can ping the device server but not Telnet to the device server on port 9999 The IP address you are trying to as
9. CPU performance mode is set to High Data Bits Indicates the number of bits in a transmitted data package The default is 8 Parity Checks for the parity bit The default is None Stop Bits The stop bit follows the data and parity bits in serial communication It indicates the end of transmission The default is 1 Pack Control Enable Packing Select to enable packing on the XPort module Two firmware selectable packing algorithms define how and when packets are sent to the network The standard algorithm is optimized for applications in which the unit is used in a local environment allowing for very small delays for single characters while keeping the packet count low The alternate packing algorithm minimizes the packet count on the network and is especially useful in applications in a routed Wide Area Network WAN Adjusting parameters in this mode can economize the network data stream Disabled by default Idle Gap Time Select the maximum time for inactivity The default time is 12 milliseconds Match 2 Byte Sequence Use to indicate the end of a series of data to be sent as one group The sequence must occur sequentially to indicate end of the data collection to the XPort device services The default is No Match Bytes Use to indicate the end of a series of data to be sent as one group Set this value to 00 if specific functions are not needed Send Frame Immediate After the
10. Device Status Network Server Serial Tunnel Hostlist Channel 1 Firmware Version ww NM 23 Oct 2014 Wired 172 19 1 1 RS232 9600 8 None 1 None Configurable Pins Apply Settings Apply Defaults XPort Device Server User Guide 39 5 Configuration via Telnet or Serial Port Setup Mode You must configure the unit so that it can communicate on a network with your serial device As an alternative to using a web browser as described in the previous chapter you can use the following procedures remotely or locally Usea Telnet connection to configure the unit over the network Use a terminal or terminal emulation program to access the serial port locally The series of prompts at which you enter configuration settings is called Setup Mode Note Detailed information about other setup methods is available from your Lantronix Sales Associate The unit s configuration is stored in nonvolatile memory and is retained without power You can change the configuration at any time The unit performs a reset after the configuration has been changed and stored This chapter tells you how to access Setup Mode and the general procedure for using it To complete the configuration continue with 6 Setup Mode Server Configuration 7 Setup Mode Channel Configuration and 8 Setup Mode Advanced Settings Note The menus in the configuration chapters show a typical device Your device may have different con
11. Figure 2 1 Product Label XINO INV LANTSONIX _ MAC Address Xrort Serial Number Barcode MAC Address 00 20 4A 82 5B 84 Serial Number XP1001000 04R Rev A11 atents 6 881 096 amp 7 018 242 Revision Date Code of Manufacturing Country of Origin Note The Part Number and MAC Adaress Serial Number on the product label will vary according the unit model XPort 03 XPort 04 or XPort 05 XPort amp Device Server User Guide 3 Using Devicelnstaller This chapter covers the steps for getting the XPort device server online and viewing its current configuration Note Devicelnstaller is a free utility program provided by Lantronix that discovers configures upgrades and manages Lantronix Device Servers lt can be downloaded from the Lantronix website at www lantronix com support downloads For instructions on using Devicelnstaller to configure the IP address and related settings or for more advanced features see the Devicelnstaller Online Help Installing Devicelnstaller To install Devicelnstaller 1 Download the latest version of Devicelnstaller from http www lantronix com downloads 2 Run the executable to start the installation process 3 Respond to the installation wizard prompts If prompted to select an installation type select Typical Assigning an IP Address The unit s IP address must be configured before it can work correctly on a network You have several options for assigning
12. IP Address 000 000 000 000 Remote Port 0 DisConnMode 00 FlushMode 00 DisConnTime 00 00 SendChar 1 00 SendChar 2 00 Baudrate The unit and attached serial device such as a modem must agree on a speed or baud rate to use for the serial connection Valid baud rates are 300 600 1200 2400 4800 9600 default 19200 38400 57600 115200 and 230400 bits per second XPort module also supports high performance baud rates of 460800 and 921600 bits per second See CPU Performance on page 66 XPort amp Device Server User Guide 48 Baudrate 9600 _ XPort Device Server User Guide 49 7 133BSetup Mode Channel Configuration I F Interface Mode The Interface I F Mode is a bit coded byte entered in hexadecimal notation I F Mode 4C _ RS 232 The following table displays available I F Mode options Note All bit positions in the table that are blank represent don t care bits for that particular option which can be set to either a 0 or 1 value Table 7 1 Interface Mode Options pev EL pe E BER UNE pw E BERI EE pue EL LL Ezra ER B EU i E EH pour LISSE LIE a eee pu ID BEAR EB 1 2 stop bits are implemented by the software This might influence performance The following table demonstrates how to build some common Interface Mode settings Table 7 2 Common Interface Mode Settings RS 232C 8 bit No
13. If DHCP is not used to assign IP addresses enter it manually in decimal dot notation The IP address must be set toa unique value in the network Subnet Mask A subnet mask defines the number of bits taken from the IP address that are assigned for the host part Default Gateway The gateway address or router allows communication to other LAN segments The gateway address should be the IP address of the router connected to the same LAN segment as the unit The gateway address must be within the local network DNS Server The DNS server allows the name of a remote machine to be resolved automatically Enter the IP address of the DNS server If the device is DHCP enabled the DHCP server provides the DNS server IP address which will override this configured value Note This setting is applicable only in Manual Connection mode 4 When you are finished click the OK button 5 On the main menu click Apply Settings XPort Device Server User Guide 23 4 Configuration Using Web Manager Ethernet Configuration You must specify the speed and direction of data transmission To specify how data will be transmitted 1 On the main menu click Network 2 Enter the following as necessary Auto Negotiate With this option the Ethernet port auto negotiates the speed and duplex with the hardware endpoint to which it is connected This is the default If this option is not selected the complete
14. Modem Control In is not asserted PELLE Ignore Modem Control In rot lll Telnet Com Port Cntrl and terminal type setup 1 j J J gume got part 7 TITITIT we EH HH AN et pp a J IIT JL prece eene J41 J M Disconnect with EOT D Py JiJ J J J 1 The Telnet Com Port Control feature is used in conjunction with Com Port Redirector The unit sends the Terminal Type upon an outgoing connection 2 A password is required for a connection to the serial port from the network 3 The TCP connection closes even if the remote site does not acknowledge the disconnection 4 When there is a network connection to or from the serial port the state LED turns off instead of blinking 5 When Ctrl D or Hex 04 is detected the connection is dropped Both Telnet Com Port Cntrl and Disconnect with EOT must be enabled for Disconnect with EOT to function properly Ctrl D is only detected going from the serial port to the network 6 When Modem Control In transitions from a high state to a low state the network connection to or from the serial port drops XPort Device Server User Guide 60 7 133BSetup Mode Channel Configuration Flush Mode Buffer Flushing Using this parameter you can control line handling and network buffers with connection startup and disconnect FlushMode 0 You can also select between two different packing algorithms Note All bit positions in the table that are blank represe
15. Parity 1 stop bit 0100 1100 RS 232C 7 bit Even Parity 1 stop bit 0111 1000 RS 485 2 Wire and RS 422 4 Wire Additional settings for RS 422 4 wire and RS 485 2 wire are available on the XPort models Note All bit positions in the table that are blank represent don t care bits for that particular option which can be set to either a 0 or 1 value XPort Device Server User Guide 50 7 133BSetup Mode Channel Configuration Table 7 3 Interface Mode Options RS 422 4 wire RS 485 2 wire Flow Flow control sets the local handshaking method for stopping serial input output Flow 0 Use the following table to select flow control options Table 7 4 Flow Control Options No flow control XON XOFF flow control Hardware handshake with RTS CTS lines XON XOFF pass characters to host Port Number The setting represents the source port number in TCP connections It is the number that identifies the channel for remote initiating connections Port No 10001 _ The default setting for Port 1 is 10001 The range is 1 65535 except for the following reserved port numbers Table 7 5 Reserved Port Numbers 1 1024 Reserved well known ports 9999 Telnet setup 14000 14009 Reserved for Redirector 30704 Reserved 77F0h 30718 Reserved 77FEh WARNING We recommend that you not use the reserved port numbers for this setting as incorrect operation may result Use Port 0 for the outgo
16. auto negotiate Security Settings Defaults Disable SNMP No SNMP community name public Disable Telnet setup No Disable TFTP Firmware Update No Disable Port 77FEh No 77FEh Access Mode 0 Read amp Write Disable Web Server No Disable Web Setup No Disable ECHO ports Yes Enable Encryption No Enable Enhanced Password No Disable Port 77F0h No XPort Device Server User Guide 75 8 Setup Mode Advanced Settings Email Settings Priority L Min notification interval 1 second All other parameters 0 e g email notification and triggers are disabled XPort amp Device Server User Guide 76 9 GPIO Interface Configurable Pins The XPort module has three pins CP1 3 that you can configure for General Purpose I O GPIO Note You can also configure the pins for serial port control lines such as hardware control modem control CTS RTS DTR and DCD and diagnostic outputs to LED using Devicelnstaller You can use these GPIO pins to control devices such as relays servers lights monitor Switches sensors and even processes such as data transfer You can set the functions for the three pins independently and in any combination The initial directions input output and active levels active low or high at boot up can also be configured through 77FE for example by using Devicelnstaller This chapter describes how the directions active levels and
17. defined within the unit Makes a connection to an IP address x x x x and the remote port ATDx x x x gn number defined within the unit Hangs up the connection Entered as ATH Enables or disables connections from the network going to the serial port n 0 disables the ability to make a connection from the network to the serial port n 1 9 enables the ability to make a connection from the network to the serial port n 1 9 is invalid Enables or disables character echo and responses n 0 disables character echo and responses ATEn n 1 enables character echo and responses Enables numeric response or full verbose n 0 enables numeric response ATVn n 1 enables full verbose Note The unit recognizes these AT commands as single commands such as ATEO or ATV1 it does not recognize compound commands such as ATEOV Send the Escape Sequence in Modem Mode Send in Modem Mode Y XPort Device Server User Guide 58 7 133BSetup Mode Channel Configuration Disable or enable the XPort device s ability to send the escape sequence The default is Y Yes send the escape sequence Show IP addr after RING Show IP addr after RING Y Disable or enable the XPort module s ability to show the IP address after RING in Modem Mode The default is Y Yes to show the IP address Auto Increment Source Port Auto increment source port N Y Yes auto increm
18. detection of the byte sequence indicates whether to send the data frame or the entire buffer Select Yes to send only the data frame The default setting is No Send Trailing Bytes Select the number of bytes to send after the end of sequence characters The default is None Flush Input Buffer Serial to Network With Active Connect Select Yes to clear the input buffer with a connection that is initiated from the device to the network The default is No With Passive Connect Select Yes to clear the input buffer with a connection initiated from the network to the device The default is No At Time of Disconnect Select Yes to clear the input buffer when the network connection to or from the device is disconnected The default is No XPort Device Server User Guide 29 4 Configuration Using Web Manager Flush Output Buffer Network to Serial With Active Connect Select Yes to clear the output buffer with a connection that is initiated from the device to the network The default is No With Passive Connect Select Yes to clear the output buffer with a connection initiated from the network to the device The default is No At Time of Disconnect Select Yes to clear the output buffer when the network connection to or from the device is disconnected The default is No 3 When you are finished click the OK button 4 On the main menu click Apply Settings Connectio
19. done through a local connection to the serial port of the XPort device server or via a secured network connection Initial configuration information including the encryption key is sent in clear text over the network To configure AES encryption on the XPort module Enable Encryption N Y Key length in bits 0 128 Change Keys N Y Enter Keys LEE LAT LTT 1 When prompted to enable encryption select Y 2 When prompted enter the encryption key length The XPort device server supports 128 192 and 256 bit encryption key lengths 3 When prompted to change keys select Y 4 Atthe Enter Keys prompt enter your encryption key The encryption keys are entered in hexadecimal The hexadecimal values are echoed as asterisks to prevent onlookers from seeing the key Hexadecimal values are 0 9 and A F Fora 128 bit key length enter 32 hexadecimal characters For a 192 bit key length enter 48 hexadecimal characters For a 256 bit key length enter 64 hexadecimal characters 5 Continue pressing Enter until you return to the Change Setup menu 6 From the Change Setup menu select option 9 to save and exit Encryption only applies to the port selected for data tunneling default 10001 regardless of whether you are using TCP or UDP Generally one of these situations applies Encrypted XPort unit to XPort unit communication Be sure to configure both XPort devices with the same encryption key
20. j lt j a weseewowwees JT j j j j even tewere ow etese fe Je j jj e a Incoming Connection Never Accept Incoming Accept with active Modem Rejects all external connection attempts Accepts external connection requests only when the Modem Control In Control In input is asserted Cannot be used with Modem Mode Always Accept Accepts any incoming connection when a connection is not b Response already established Default setting Character Response A single character is transmitted to the serial port when there is a change in connection state C connected D disconnected N host unreachable The IP address of the host connecting to the CoBos device will be provided when you use verbose mode This option is overridden when the Active Start Modem Mode or Active Start Host List is in effect Default setting is Nothing quiet c Active Startup No Active Startup Does not attempt to initiate a connection under any circumstance Default setting With Any Character Attempts to connect when any character is received from the serial port With active Modem Control In Attempts to connect when the Modem Control In input changes from not asserted to asserted With a Specific Start Character Attempts to connect when it receives a specific start character from the serial port The default start character is carriage return XPort Device
21. local port number Auto increment for active connect Select to auto increment the local port number for new outgoing connections The range of auto incremented port numbers is 50 000 to 59 999 and loops back to the beginning when the maximum range is reached Remote Port Enter the remote port number Remote Host Enter the IP address of the remote device XPort Device Server User Guide 32 4 Configuration Using Web Manager Common Options Telnet Com Port Cntrl This field is available for configuration only when Active Connect is set to None Select Enable to permit Telnet communication to the unit The Telnet Com Port Cntrl feature is used in conjunction with the Com Port Redirector CPR utility See the CPR online Help for details Terminal Name This field is available for configuration only when Telnet Mode is set to Enable Use the terminal name for the Telnet terminal type Enter only one name When this option is enabled the unit also reacts to the end of record EOR and binary options which can be used for applications such as terminal emulation to IBM hosts Connect Response A single character is transmitted to the serial port when there is a change in connection state Default setting is None Use Hostlist If this option is set to True the device server scrolls through the host list until it connects to a device listed in the host list table Once it conne
22. nomenclature of the firmware Online Status Non configurable field Displays the XPort device s status as online offline unreachable the XPort module is on a different subnet or busy the XPort device server is currently performing a task IP Address Non configurable field Displays the XPort module s current IP address To change the IP address see Assigning an IP Address on page 16 IP Address was Obtained Displays Dynamically if the XPort module automatically received an IP address e g from DHCP Displays Statically if the IP address was configured manually If the IP address was assigned dynamically the following fields appear Obtain via DHCP with value of True or False Obtain via BOOTP with value of True or False Obtain via RARP with value of True or False Obtain via Auto IP with value of True or False XPort Device Server User Guide 18 3 Using Devicelnstaller Subnet Mask Non configurable field Displays the XPort module s current subnet mask To change the subnet mask see Assigning an IP Address on page 16 Gateway Non configurable field Displays the XPort device s current gateway To change the gateway see Assigning an IP Address on page 16 Number of COB partitions supported Non configurable field Displays the number of COB partitions supported Number of Ports Non configurable field Displays the number of ports o
23. states can be dynamically controlled and probed through special port 77F0 The configurable pins default configuration is Function General Purpose Input Active Level Active Low Features TCP and UDP can be used The protocol supports up to 32 GPIO for future products Function configuration can be retrieved Input or output selection can be retrieved and controlled Active low or high selection can be retrieved and controlled Active or inactive selection can be retrieved and controlled TTFO can be disabled 999999 Every change of state active inactive requires a command over TCP or UDP and thus is not very fast If you use this port for data transfer the throughput is low usually up to 1 Kbps Control Protocol The GPIO control protocol is a simple proprietary protocol XPort amp Device Server User Guide TT Guidelines The GPIO control protocol is described from the PC side Send means from PC to XPort module Response comes from XPort device server to PC The protocol allows for control of up to 32 GPIOs How many are actually available depends on the product XPort module has only three The parameters are four bytes long and represent GPIOs 0 31 with GPIOO in bit 0 of the first byte Little Endian Parameter bits for configurable pins not configured as GPIOs are undefined for Get commands and ignored on Set commands Every command consists of nine bytes one command type of one byte and two paramete
24. 0 2X where X is any digit The menu shows you a list of current entries already defined in the product 2 To delete modify or add an entry select Yes If you enter an IP address of 0 0 0 0 that entry and all others after it are deleted 3 After completing the hostlist repeat the previous step if necessary to edit the hostlist again 4 ForRetrycounter enter the number of times the Lantronix unit should try to make a good network connection to a hostlist entry that it has successfully ARPed The range is 1 15 with the default set to 3 XPort Device Server User Guide 55 7 133BSetup Mode Channel Configuration 5 For Retrytimeout enter the number of milliseconds the unit should wait before failing an attempted connection The time is stored as units of milliseconds in the range of 10 65535 The default is 250 d Datagram Type Directed UDP When selecting this option you are prompted for the Datagram type Enter 01 for directed or broadcast UDP Datagrams of type 01 can be sent as a broadcast by enabling the Send as Broadcast option The default is not to broadcast When the UDP option is in effect the unit never attempts to initiate a TCP connection because it uses UDP datagrams to send and receive data e Modem Mode In Modem Emulation Mode the unit presents a modem interface to the attached serial device It accepts AT style modem commands and handles the modem signals correctly Normally there
25. 5 XP1001000 05R XP1002000 05R XP100200S 05R It provides the information needed to configure use and update the XPort firmware and is intended for OEMs and system integrators who are embedding the XPort module in their end product designs Chapter Summary The remaining chapters in this guide include 2 Introduction Describes the main features of the XPort module and the protocols it supports 3 Using Devicelnstaller Provides information for getting your unit up and running using Devicelnstaller to assign an IP address 4 Configuration Using Web Details using the Web Manager to set parameters such as port Manager and server properties 5 Configuration via Telnet or Serial Provides instructions for accessing Setup Mode command Port Setup Mode line interface using a Telnet connection through the network or a terminal or terminal emulation program through the serial port 6 Setup Mode Server Details the network server settings Configuration 7 Setup Mode Channel Details the serial port settings Configuration 8 Setup Mode Advanced Settings Details email expert and security settings and explains how to reset the unit to factory default values XPort amp Device Server User Guide 10 1 Using This Guide 9 GPIO Interface Provides instructions for configuring the three General Purpose l O pins CP1 3 10 Firmware Upgrades Provides instructions for obtaining the latest firmware and updating the XPo
26. Guide 11 2 Introduction This chapter summarizes the XPort device server s features and the basic information needed to get started Capabilities The XPort device server has the following capabilities Connects devices through a TCP data channel or through a Telnet connection to computers or to another device server The XPort module also supports UDP datagrams Contains a web HTTP server allowing presentation of custom content and easy configuration through a browser Has three programmable I O pins used to monitor or control attached devices Applications The XPort device server connects serial devices such as those listed below to Ethernet networks using the IP protocol family ATM machines CNC controllers Data collection devices Environmental sensors Universal Power Supply UPS management units Telecommunications equipment Data display devices Security alarms and access control devices Handheld instruments Modems 9999999999 Time attendance clocks and terminals XPort amp Device Server User Guide 12 2 Introduction Protocol Support The XPort device server uses the Internet Protocol IP for network communications lt uses the Transmission Control Protocol TCP to assure that no data is lost or duplicated and that everything sent to the connection arrives correctly at the target Supported protocols include ARP UDP TCP ICMP Telnet TFTP AutolP DHCP HTTP and SNM
27. Incoming Select Yes to accept incoming connections The default is Yes Required Determines whether a password is required for an incoming passive connection This field is not available when a password is set for Telnet mode Password If Password Required was set to Yes enter the password for passive connections Connect Mode Active Connection Active Connect Select None to disable Active Connect Otherwise indicate the connection type from the drop down list With Any Character Attempts to connect when any character is received from the serial port With Active Mdm Ctrl In Accepts external connection requests only when the Modem Control In input is asserted With Start Character Attempts to connect when it receives a specific start character from the serial port The default start character is carriage return Manual Connection Attempts to connect when directed by a command string received from the serial port Auto Start Automatically connects to the remote IP address and port after booting up Start Character If Active Connect is set to With Start Character enter the start character in this field Modem Mode Indicates the on screen response type when in Modem Mode if Modem Mode is enabled Show IP Address After Ring Indicates whether to display the remote IP address upon connection The default setting is Yes Endpoint Configuration Local Port Enter the
28. Information Label 14 Using Devicelnstaller 16 Installing Devicelnstaller 16 Assigning an IP Address 16 Accessing the XPort Module Using Devicelnstaller 17 Viewing the Current Configuration 17 Configuration Using Web Manager 20 Accessing Web Manager Using Devicelnstaller 20 Network Configuration 22 XPort Device Server User Guide 4 Table of Contents Network Mode 22 Automatic IP Address Configuration 22 Static IP Address Configuration 23 Ethernet Configuration 24 Server Configuration 25 Server Configuration 25 Advanced 26 Host List Configuration 26 Retry Settings 27 Host Information 27 Channel 1 Configuration 27 Serial Settings 28 Connection Settings UDP 34 Email Configuration 35 Recipients 36 Trigger Configuration 36 Conditions 36 Message Properties 37 Configurable Pin Settings 37 Configurable Pin Functions 38 Apply Settings 38 Apply Defaults 38 5 Configuration via Telnet or Serial Port Setup Mode 40 Accessing Setup Mode 40 Telnet Connection 40 Serial Port Connection 42 Exiting Setup Mode 42 6 Setup Mode Server Configuration 43 Server Configuration Option 0 43 IP Address 43 Set Gateway IP Address 45 Netmask Number of Bits for Host Part 45 Set DNS Server IP Address 45 Change Telnet Web Manager Password 46 DHCP Name 46 XPort Device Server User Guide 5 Table of Contents
29. LANTRONIX K aso A Xrort Device Server User Guide Part Number 900 270 Revision P November 2014 Intellectual Property 2014 Lantronix All rights reserved No part of the contents of this book may be transmitted or reproduced in any form or by any means without the written permission of Lantronix Lantronix DeviceLinx and XPort are registered trademarks of Lantronix U S Patents 6 881 096 7 018 242 7 698 405 8 010 789 8 024 446 8 219 661 8 504 740 8 788 814 Additional patents pending Ethernet is a trademark of XEROX Corporation UNIX is a registered trademark of The Open Group Windows is a trademark of Microsoft Corp Warranty For details on the Lantronix warranty policy please go to our Web site at www lantronix com support warranty Contacts Lantronix Corporate Headquarters 167 Technology Drive Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online www lantronix com support Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact Disclaimer All information contained herein is provided AS IS Lantronix undertakes no obligation to update the information in this publication Lantronix does not make and specifically disclaims all warranties of any kind express implied or otherwise regarding title non infringement fitness quality
30. Note TFTP requires the rom binary version of the unit s internal operational code 2 In the TFTP server field enter the IP address of the unit being upgraded 3 Select Upload operation and Binary format 4 Enter the full path of the firmware file in the Local file name field 5 Inthe Remote file name field enter the current internal operational code or WEB1 to WEB 6 for the internal web interface XPort amp Device Server User Guide 82 Figure 10 2 TFTP Window TFTP Client TFTP server 172 20 206 64 Upload Now Operation 4 Upload Mi Format Binary M q Local file name Weird Solutions xpt03_6507 rom a Settings Remote file name x5 Help 0 Copyright 1996 2002 Weird Solutions Inc All rights reserved 6 Click the Upload Now button to transfer the file to the unit The unit performs a power reset after the firmware has been loaded and stored After the firmware has been loaded and stored which takes approximately 8 seconds to complete the unit performs a power reset Using TFTP Command Line Interface To download new firmware from a computer 1 Enter the following from a TFTP command line interface tftp i ip address put local filename destination file name The following examples below demonstrate the TFTP command sequence to download the rom file and the cob file for each XPort model For XPort 05 modules tftp i 192 168 1 111 put x
31. P for network communications and management TCP UDP and Telnet for connections to the serial port TFTP for firmware and web page updates IP for addressing routing and data block handling over the network User Datagram Protocol UDP for typical datagram applications in which devices interact with other devices without maintaining a point to point connection 9 SMTP for email transmission Configuration Methods For the unit to operate correctly on a network it must have a unique IP address on the network There are three basic methods for logging into the device server to assign an IP address and configure the unit Devicelnstaller Assign an IP address and view the current XPort module configuration using a Graphical User Interface GUI on a PC attached to a network See 3 Using Devicelnstaller Web Manager Through a web interface configure the XPort and its settings using the XPort module s Web Manager See 4 Configuration Using Web Manager Serial amp Telnet Ports There are two approaches to accessing Serial Mode Make a Telnet connection to the network port 9999 or connect a terminal or a PC running a terminal emulation program to the unit s serial port See 5 Configuration via Telnet or Serial Port Setup Mode Addresses and Port Numbers Hardware Address You need to know the unit s hardware address also known as a MAC address It is on the product label in one of the following forma
32. Port folder The list of available XPort modules displays 3 Expand the list of XPort device servers by clicking the symbol next to the XPort icon 4 Select the XPort unit by clicking its hardware address 5 Inthe right pane click the Web Configuration tab 6 To view the XPort module s Web Manager in the current Devicelnstaller window click the Go button To open the Web Manager in a web browser click the External Browser button Note Alternatively to open Web Manager open your web browser and enter the IP address of the XPort device server With firmware 1 8 or earlier your browser must be JAVA enabled to use Web Manager With firmware 6 1 0 0 and later your web browser does not need to be JAVA enabled A dialog box appears to prompt for a User name and Password XPort amp Device Server User Guide 20 4 Configuration Using Web Manager Figure 4 1 Web Manager Login Window Authentication Required Enter username and password For http 172 19 205 3 User Name Password Ce Ce 7 Perform one of the following If no Telnet password has been defined default leave both fields blank and click OK Ifa Telnet password has been defined leave the username blank type in the password and then click OK The Web Manager displays Figure 4 2 Lantronix Web Manager Xrort LANT3ONIX Device Status Network Server Serial Tunnel Hostlis
33. Product Label 15 Figure 4 1 Web Manager Login Window 21 Figure 4 2 Lantronix Web Manager 21 Figure 4 3 Network Settings 22 Figure 4 4 Server Settings 25 Figure 4 5 Hostlist Settings 27 Figure 4 6 Channel Serial Settings 28 Figure 4 7 TCP Connection Settings 31 Figure 4 8 UDP Connection Settings 34 Figure 4 9 Email Settings 35 Figure 4 10 Email Trigger Settings 36 Figure 4 11 Configurable Pins Settings 37 Figure 4 12 Apply Settings and Apply Defaults 39 Figure 5 1 MAC Address 41 Figure 5 2 Setup Menu Options 41 Figure 7 1 Serial Port Parameters 48 Figure 7 2 Apply Settings and Apply Defaults 55 Figure 8 1 Email Settings 64 Figure 8 2 Expert Settings 67 Figure 8 3 Security Settings 70 List of Tables Table 6 1 BootP DHCP AutolP options 43 Table 6 2 Standard IP Network Netmasks 45 Table 7 3 Interface Mode Options 51 Table 7 4 Flow Control Options 51 Table 7 5 Reserved Port Numbers 51 Table 7 6 Connect Mode Options 52 Table 7 7 Manual Connection Address Example 54 Table 7 8 Modem Mode Messages 56 Table 7 9 Modem Mode Commands 58 Table 7 10 Disconnect Mode Options 60 Table 7 11 Flush Mode Options 61 Table 7 12 Pack Control Options 62 XPort Device Server User Guide 9 1 Using This Guide Purpose and Audience This user guide covers these Lantronix DeviceLinx XPort device server modules XPort 03 XP1001000 03R XP1002000 03R XP100200S 03R XPort 04 XP1001000 04R XP1002000 04R XP100200S 04R XPort 0
34. Serial Trigger Input Trigger Input 2 None MI Channel v Trigger Input 3 None v Data Size v Match gt Data Ox Ox in Hex Message Properties Message Priority Low Min Notification Interval J secs Re notification Interval 0 secs 2 Configure or modify the following fields Conditions Configurable Pins Select the condition from the drop down menu for the XPort Device Server User Guide 36 4 Configuration Using Web Manager configurable pins Repeat for each Trigger Input field Enable Serial Trigger Input Enabling this option causes specified serial communications to count as a trigger input Channel Select the channel prompting the trigger For the XPort device server there is only one channel Data Size Select the data size prompting the trigger Match Data Enter the data which when it appears in the communication stream prompts a trigger Note All of the conditions must match for the XPort module to send an email notification Message Properties Message The subject line of the trigger event email to the specified recipient s Priority The priority level for the email Min Notification Interval The minimum time allowed between individual triggers If a trigger event occurs within the minimum interval since the last trigger it is ignored Re notification Interval The time interval in which a new email messag
35. Server User Guide 53 7 133BSetup Mode Channel Configuration Manual Connection Attempts to connect when directed by a command string received from the serial port The first character of the command string must be a C ASCII 0x43 and the last character must be either a carriage return ASCII OxOD or a line feed 0x0A No blanks or space characters may be in the command string Between the first and last command string characters must be a full or partial destination IP address and may be a destination port number The IP address must be in standard decimal dot notation and may be a partial address representing the least significant 1 2 or 3 bytes of the remote IP address The period is required between each pair of IP address numbers If present the port number must follow the IP address must be presented as a decimal number in the range 1 65535 and must be preceded by a forward slash ASCII Ox2F The slash separates the IP address and the port number If you omit the port number from a command string the internally stored remote port number starts a connection If a partial IP address is presented in a command string it is interpreted to be the least significant bytes of the IP address and uses the internally stored remote IP address to provide the most significant bytes of the IP address If the IP address entered is 0 0 0 0 0 the device server enters Monitor Mode For example if the remote IP address already conf
36. Third party application to XPort unit encrypted communication XPort module uses standard AES encryption protocols To communicate successfully products and applications on the peer side must use the same protocols and the same encryption key as the XPort device server Lantronix Secure Com Port Redirector provides an encrypted connection from Windows based applications to the XPort module Information about SCPR is at XPort Device Server User Guide 73 8 Setup Mode Advanced Settings www lantronix com device networking utilities tools scpr A 30 day trial version of SCPR is available Note Developers can license the Lantronix Encryption Library Suite See www lantronix com device networking utilities tools Enable Enhanced Password This setting defaults to the N No option which allows you to set a 4 character password that protects Setup Mode by means of Telnet and web pages The Y Yes option allows you to set an extended security password of 16 characters for protecting Telnet and Web Page access Enable Enhanced Password Y _ Disable Port 77F0 Hex Port 77F0 is a setting that allows a custom application to query or set the three XPort module configurable pins when they are functioning as general purpose I O GPIO You may want to disable this capability for security purposes The default setting is the N No option which enables GPIO control The Y Yes option disables the GPIO contr
37. Tools menu The Ping Device dialog box shows the IP address of the selected unit 8 From the Tools menu click the Ping button The results display in the Status window Click the Clear Status button to clear the window so you can ping the device again Note If you do not receive Reply messages make sure the unit is properly attached to the network and that the IP address assigned is valid for the particular network segment you are working with If you are not sure check with your systems administrator 9 Click the Close button to close the dialog box and return to the main window Accessing the XPort Module Using Devicelnstaller 1 Click Start gt All Programs Lantronix Devicelnstaller 4 3 Devicelnstaller 2 Click the XPort folder The list of available Lantronix XPort devices displays 3 Expand the list of XPort modules by clicking the symbol next to the XPort icon Select the XPort unit by clicking on its IP address to view its configuration Viewing the Current Configuration Devicelnstaller provides a view of the unit s configuration To view the unit s current settings 1 Follow the instructions above to locate the XPort module 2 Inthe right pane click the Device Details tab The current XPort device configuration displays Name Configurable field A name that identifies the XPort module Double click the field type in the value and press Enter to complete This name is not visible on other PCs or laptops u
38. Trigger 2 Refer to Trigger 1 for details on completing these fields Note Each trigger is independent of the others Each condition within an individual trigger must be met before the unit sends the email Trigger 3 Refer to Trigger 1 for details on completing these fields Note Each trigger is independent of the others Each condition within an individual trigger must be met before the unit sends the email Expert Settings Option 5 Note You can change the Enable alternate MAC setting using telnet or serial connections only It is not available through the Web Manager CAUTION Only an expert should change these parameters You must definitely know the consequences the changes might have Figure 8 2 Expert Settings TCP Keepalive time in s 1s 65s Os disable 45 ARP Cache timeout in s 1s 600s 600 CPU performance 0 Regular 1 Low 2 High 0 Disable Monitor Mode bootup N RS485 tx enable active level 0 10ow 1 high 0 HTTP Port Number 80 SMTP Port Number 25 MTU Size 512 1400 1400 TCP Re transmission Timeout 500 4000 ms 500 Enable alternate MAC N Ethernet connection type 0 XPort Device Server User Guide 67 8 Setup Mode Advanced Settings The default settings are listed below TCP Keepalive time in s 45 1s 65s 0s disable ARP Cache timeout in s 600 1s 600s
39. User Guide 42 6 Setup Mode Server Configuration This chapter explains how to configure the network settings Note Current values appear in parentheses Server Configuration Option 0 The unit s basic network parameters display when you select Server configuration option 0 The IP Address Set Gateway IP Address and Netmask fields display the current values IP Address 000 000 000 000 Set Gateway IP Address N Netmask Number of Bits for Host Part 0 default 0 Set DNS Server IP addr N Change Telnet Web Manager password N Change DHCP device name not set N Enable DHCP FQDN option N IP Address If DHCP is not used to assign IP addresses enter the IP address manually The IP address must be set to a unique value in the network Enter each octet and press Enter between each section The current value displays in parentheses IP Address 0 0 0 O If DHCP is used the third octet of the IP address sets the BootP DHCP AutoIP options The following table shows the bits you can manually configure to force the XPort module to disable AutoIP DHCP or BootP To disable an option set the appropriate bit Table 6 1 BootP DHCP AutolP options AutolP BootP DHCP XPort Device Server User Guide 43 6 Setup Mode Server Configuration For example if the third octet is 0 0 5 0 the AutolP and BootP options are disabled only DHCP is
40. able field Displays True Supports HTTP Setup Non configurable field Displays True Supports 230K Baud Rate Non configurable field Displays True Supports GPIO Non configurable field Displays True indicating the XPort module supports General Purpose Input Output GPIO XPort Device Server User Guide 19 4 Configuration Using Web Manager You must configure the unit so that it can communicate on a network with your serial device For example you must set the way the unit will respond to serial and network traffic how it will handle serial packets and when to start or close a connection The unit s configuration is stored in nonvolatile memory and is retained without power You can change the configuration at any time The unit performs a reset after you change and store the configuration In this chapter we describe how to configure the XPort device server using Web Manager Lantronix s browser based configuration tool For information on using Setup Mode our command line configuration interface see 5 Configuration via Telnet or Serial Port Setup Mode Note The examples in this section show a typical device Your device may have different configuration options Accessing Web Manager Using Devicelnstaller Note For more information on Devicelnstaller see 3 Using Devicelnstaller 1 Run Devicelnstaller and search for the list of available Lantronix device servers 2 Click on the X
41. accuracy completeness usefulness suitability or performance of the information provided herein Lantronix shall have no liability whatsoever to any user for any damages losses and causes of action whether in contract or in tort or otherwise in connection with the user s access or usage of any of the information or content contained herein The information and specifications contained in this document are subject to change without notice Operation of this equipment in a residential area is likely to cause interference in which case the user at his or her own expense will be required to take whatever measures may be required to correct the interference Note Changes or modifications to this device not explicitly approved by Lantronix will void the user s authority to operate this device XPort Device Server User Guide 2 Revision History January 2007 A Initial release May 2007 Added information about product support for RS485 August 2007 C Added XChip Direct information November 2003 Revised for version 1 6 of the firmware April 2004 Information to support XPort 03 August 2004 Added XPort 485 functionality Updated common settings for all models October 2004 Updates e Added reference documentation March 2005 January 2006 H Revised for version 6 1 of the firmware August 2007 Added XChip information September Updated for XPort 04 removed XPort 01 references 2009 June 2010 L 6 Minor technical correcti
42. an IP to your unit We recommend that you manually assign the IP address over the network using Devicelnstaller Note To use a serial connection instead of an Ethernet connection to configure the device see 5 Configuration via Telnet or Serial Port Setup Mode on page 42 The unit s IP address is normally set to 0 0 0 0 at the factory The hardware address is on the product label The unit is DHCP enabled as the default To assign an IP address manually 1 Click Start AII Programs Lantronix Devicelnstaller 4 3 Devicelnstaller If your PC has more than one network adapter a message displays Select an adapter and click OK Note If the unit already has an IP adaress e g DHCP has assigned an IP address click the Search icon and select the unit from the list of Lantronix device servers on the local network e 2 Click the Assign IP s icon XPort amp Device Server User Guide 16 3 Using Devicelnstaller 3 If prompted enter the hardware address on the product label and click Next 4 Select Assign a specific IP address and click Next 5 Enter the IP address The Subnet mask displays automatically based on the IP address if desired you may change it On a local network you can leave the Default gateway blank all zeros Click Next 6 Click the Assign button and wait several seconds until a confirmation message displays Click Finish 7 Select the device from the main window list and select Ping from the
43. assword creation allowing you to create basic passwords up to 4 bytes in length Telnet Web Enter the password required for Telnet configuration and Web Manager Password Manager access XPort Device Server User Guide 25 4 Configuration Using Web Manager Retype Password Re enter the password required for Telnet configuration and Web Manager access Advanced ARP Cache Timeout When the unit communicates with another device on the network it adds an entry into its ARP table ARP Cache timeout defines the number of seconds 1 600 before it refreshes this table TCP Keepalive TCP Keepalive time defines how many seconds the unit waits during an inactive connection before checking its status If the unit does not receive a response it drops that connection Enter a value between 0 and 60 seconds 0 disables keepalive The default setting is 45 Monitor Mode Bootup Select Disable to disable entry into the monitor mode using the yyy or xx1 key sequence at startup This field prevents the unit from entering monitor mode by interpreting the stream of characters that are received during the device server s initialization at startup CPU Performance Mode Select the XPort device server s performance mode Higher performance settings require more energy Low is 26 MHz Regular is 48 MHz High is 88 MHz The default is Regular HTTP Server Port This option allows the configuration
44. at particular option which can be set to either a 0 or 1 value XPort Device Server User Guide 61 7 133BSetup Mode Channel Configuration Table 7 12 Pack Control Options Packing Interval Interval 12ms Interval 52ms Interval 250ms Interval 5sec Trailing Characters ENGUON qe Send Characters 2 Byte Send Character Sequence LL J J J J Send Immediately After Send chars J J J J J I Packing Interval Two Packing Interval defines how long the unit should wait before sending accumulated characters This wait period is between successive network segments containing data For alternate packing the default interval is 12 ms Trailing Characters In some applications CRC Checksum or other trailing characters follow the end of sequence character this option helps to adapt frame transmission to the frame boundary Send Characters f 2 Byte Send Character Sequence is enabled the unit interprets the sendchars as a 2 byte sequence if this option is not enabled the unit interprets them independently If Send Immediately After Characters is not set any characters already in the serial buffer are included in the transmission after a transmit condition is found If this option is set the unit sends immediately after recognizing the transmit condition sendchar or timeout Note A transmission might occur if status information needs to be exchanged or an acknowledgment needs to be
45. at the DOS prompt of your computer ARP D X X X X X X X X is the IP of the device server PING X X X X X X X X is the IP of the device server If you get a response then there is a duplicate IP address on the network If you do not get a response use the serial port to verify that Telnet is not disabled XPort Device Server User Guide 89 The device server appears to be set up correctly but you are not communicating with your device attached to the device server across the network When connecting to the Web Manager within the device server the No Connection With The Device Server message displays If you are sure that the serial port setting is correct then you may not be connecting to the correct socket of the device server Another possibility is that the device server is not set up correctly to make a good socket connection to the network Your computer is not able to connect to port 30718 77FEh on the device server You can check to see whether there is a socket connection to or from the device server by checking the state of CP1 if it has been configured for LED1 functionality If the state of CP1 is blinking consistently or is completely off then there is a good socket connection If the state of CP1 is low use the Connect Mode option CO for making a connection to the device server from the network Use Connect Mode option C1 or C5 for a connection to the network fr
46. can Initiates a wireless scan if the wireless interface is enabled Reports any stations found including BSSID SSID and RSSI If SA is followed by a string the string is used to filter SSIDs before reporting If the BSS does not broadcast its SSID only the BSSID and RSSI are returned SC x x x x Send Configuration Sets configuration of unit with IP address x x x x from hex records Set Security record Sets the Security record without the encryption key and length parameters The entire record must still be written but the encryption specific bytes do not z Oo XPort amp Device Server User Guide 86 need to be provided they can be null since they are not overwritten TCP Connection Shows all incoming and outgoing TCP connections Table VN Query full firmware This command queries and displays full firmware version version in readable string format VS x x x x Version Queries software header record 16 bytes of unit with IP address x x x x WC Flash write count This command shows serial flash write counts valid only on serial flash products Note Entering any of the commands listed above generates one of the following command response codes Table 11 2 Command Response Codes No answer from remote device Cannot reach remote device or no answer Wrong parameter s Invalid command XPort amp Device Server User Guide 87 12 Troubleshooting This chapter discusses how you can diagnose and fix err
47. cation interval 0 s Trigger 2 XPort amp Device Server User Guide 64 8 Setup Mode Advanced Settings Enable serial trigger input N Trigger inputl A I X X Trigger input2 A I X X Trigger input3 A I X X Message Priority L Min notification interval 1 s Re notification interval 0 s Trigger 3 Enable serial trigger input N Trigger inputl A I X X r rigger input2 A I X X Trigger input3 A I X X Message Priority L Min notification interval 1 s Re notification interval 0 s Mail Server Enter the IP address of the mail server Enter each 3 digit section and press Enter between each section inputted The current value is displayed in parentheses Mail server 0 0 0 0 000 000 000 000 __ Unit Name Enter the username used by the XPort module to send email messages The current value is displayed in parentheses Unit name Domain Name Enter the email server s domain name The current value is displayed in parentheses XPort Device Server User Guide 65 8 Setup Mode Advanced Settings Domain name _ Recipient 1 Enter the full email address of the trigger email recipient The current value is displayed in parentheses Recipient 1 _ Recipient 2 Enter the full email address of the trigger email recipient The current value is disp
48. complete this procedure Note For more information see Recovering Firmware in the Devicelnstaller online Help XPort amp Device Server User Guide 84 11 Monitor Mode Monitor Mode is a command line interface used for diagnostic purposes There are two ways to enter Monitor Mode locally using the serial port or remotely using the network Entering Monitor Mode Using the Serial Port To enter Monitor Mode locally 1 Follow the same steps used for setting the serial configuration parameters see Serial Port on page 42 2 Instead of typing three x keys however 3 Type zzz or xx1 to enter Monitor Mode with network connections 4 Type yyy or yy1 to enter Monitor Mode without network connections A 0 prompt indicates that you have successfully entered Monitor Mode Entering Monitor Mode Using the Network Port To enter Monitor Mode using a Telnet connection 1 Establish a Telnet session to the configuration port 9999 The following message appears MAC address 0080A394616E Software version V6 10 0 0 130207 XPTEXE AES library version 1 8 2 1 2 Type M upper case A 0 prompt indicates that you have successfully entered Monitor Mode Monitor Mode Commands The following commands are available in Monitor Mode Many commands have an IP address as an optional parameter xxx xxx xxx xxx If you enter the IP address the command is applied to another unit with that IP add
49. cts the unit stops trying to connect to any others If this connection fails the unit continues to scroll through the table until it connects to another IP in the host list The host list is disabled for Manual Mode and for Modem Mode The unit will not accept a data connection from a remote device when the host list option is enabled LED Select Blink for the status LEDs to blink upon connection or None for no LED output Disconnect Mode On Mdm_Ctrl_In Drop Set to Yes for the network connection to or from the serial port to disconnect drop when Modem Control In transitions from an asserted state to not asserted state The default setting is No Hard Disconnect When set to Yes the TCP connection closes even if the remote site does not acknowledge the disconnect request Check EOT Ctrl D Select Yes to drop the connection when Ctrl D or Hex 04 is detected Both Telnet Com Port Cntrl and Check EOT Ctrl D must be enabled for Disconnect with EOT to function properly Ctrl D is only detected going from the serial port to the network The default setting is No Inactivity Timeout Use this parameter to set an inactivity timeout The unit drops the TCP connection to port 10001 if there is no activity on the serial line before the set time expires Enter time in the format mm ss where m is the number of minutes and s is the number of seconds To disable the inactivity timeout enter 00 00 Note The d
50. d of record and binary options useful for applications like terminal emulation to IBM hosts Channel Port Password This parameter appears only if the channel port password option is enabled in Disconnect Mode With this option enabled you can set a password on the serial port XPort Device Server User Guide 63 8 Setup Mode Advanced Settings Email Settings Option 3 Note You can change these settings using Telnet a serial connection or Web Manager with firmware versions 6 1 0 0 or later Earlier versions do not allow you to configure email triggers using Web Manager To configure email settings using Devicelnstaller see Email Notification in the Devicelnstaller Online Help The unit sends an email to multiple recipients when a specific trigger event occurs There are three separate triggers based on any combination of the configurable pins PIO when selected as user I O functions Optionally use a two byte serial string to initiate a trigger To configure email configuration settings select Email option 3 from the Change Setup menu Figure 8 1 Email Settings Mail server 0 0 0 0 000 000 000 000 Unit name Domain name Recipient 1 Recipient 2 Trigger 1 Enable serial trigger input N Trigger inputl A I X X Trigger input2 A I X X m rigger input3 A I X X Message Priority L Min notification interval 1 s Re notifi
51. e is sent to the recipient s when a single trigger event remains active 3 When you are finished click the OK button 4 Onthe main menu click Apply Settings Configurable Pin Settings There are three configurable hardware pins on the XPort unit For each pin configure the pin function communication direction and activity level For more information see 9 GP O Interface To configure the XPort module s Configurable Pins 1 On the main menu click Configurable Pins The Configurable Pins page opens Figure 4 11 Configurable Pins Settings CP Function Direction Active Level 1 General Purpose I O G Input O Output Low O High 2 General Purpose I O Input output Low O High 3 General Purpose I O input output Low O High XPort Device Server User Guide 37 4 Configuration Using Web Manager 2 Configure or modify the following fields for each pin Function From the drop down menu select the purpose of the specified pin See Configurable Pin Functions below for a description of each available function Direction Select whether the pin functions as an input or output Active Level Select the signal active level Low or High Configurable Pin Functions General Purpose I O Monitors input using the 77F0 port or controls output by the 77F0 port HW Flow Control Out Allows for flow control on the connection with hardware hands
52. ed from the serial interface When a connection is terminated or lost the unit reverts to command mode When an active connection is in effect the unit terminates the connection if it receives the following sequence from the attached serial device No serial data is received for one second The character sequence is received with no more than one second between each two characters No serial data is received for one second after the last character At this time the unit responds affirmatively per the selected echo response mode The character string ATH is received terminated with a carriage return The unit responds affirmatively according to the selected echo response mode and drops the network connection The serial interface reverts to accepting command strings If this sequence is not followed the unit remains in data transfer mode XPort Device Server User Guide 57 7 133BSetup Mode Channel Configuration Table 7 9 Modem Mode Commands ATDTx x x X pppp ATDTx x x X pppp or Makes a connection to an IP address x x x x and a remote port number pppp ATDTx x x x pppp ATDTX X XX Makes a connection to an IP address x x x x and the remote port number defined within the unit Forces the unit into Monitor Mode if a remote IP address and port ATDO 0 0 0 b number are defined within the unit ATD or ATDT Forces the unit into Monitor Mode ifa remote IP address and port number are not
53. efault port number for Port 1 is 10001 and 10002 for Port 2 However port numbers may be set to a different value 3 When you are finished click the OK button 4 Onthe main menu click Apply Settings XPort amp Device Server User Guide 33 4 Configuration Using Web Manager Connection Settings UDP To configure a channel s UDP settings 1 On the main menu click Connection The Connection Settings window for the selected channel displays In the available fields enter or modify the following information Figure 4 8 UDP Connection Settings Connection Settings Channel 1 Connect Protocol Protocol UDP v Datagram Mode Accept Incoming Remote Port f Use Broadcast Datagram Type 00 v Endpoint Configuration Local Port 10001 Remote Host 0 0 Device Address Table Connect Protocol No Dev Addr No 1 5 g Dev Addr No Dev Addr Dev Addr Protocol Select UDP from the drop down menu Datagram Mode Datagram Type Configures the remote IP or network broadcast address and the remote port Enter 01 for directed or broadcast UDP The default setting is 00 Accept Incoming Select Yes to accept incoming UDP datagrams Endpoint Configuration Local Port Enter the local port number Remote Port Enter the port number of the remote device Remote Host Enter
54. enabled The value 5 results from adding the binary equivalents of 0 and 2 This is the most common setting when using DHCP XPort Device Server User Guide 44 6 Setup Mode Server Configuration Set Gateway IP Address The gateway address or router allows communication to other LAN segments The gateway address should be the IP address of the router connected to the same LAN segment as the unit The gateway address must be within the local network The default is N No meaning the gateway address has not been set To set the gateway address type Y and enter the address Set Gateway IP Address N Y Gateway IP addr 0 0 0 0 Netmask Number of Bits for Host Part A netmask defines the number of bits taken from the IP address that are assigned for the host part Netmask Number of Bits for Host Part 0 default 0 _ Note Class A 24 bits Class B 16 bits Class C 8 bits The unit prompts for the number of host bits to be entered then calculates the netmask which appears in standard decimal dot notation for example 255 255 255 0 when the saved parameters display Table 6 2 Standard IP Network Netmasks 255 0 0 0 Set DNS Server IP Address The DNS server allows the name of a remote machine to be resolved automatically The default is N No indicating the DNS server address has not been set To set the DNS server address type Y At the prompt enter the DNS server address I
55. ent the source port The XPort unit increments the port number used with each new connection Remote IP Address This is the destination IP address used with an outgoing connection Remote IP Address 000 000 000 000 Note This option does not display when Hostlist is enabled from the ConnectMode prompt see Connect Mode on page 52 for more information Remote Port You must set the remote TCP port number for the unit to make outgoing connections This parameter defines the port number on the target host to which a connection is attempted Remote Port 000 To connect an ASCII terminal to a host using the unit for login purposes use the remote port number 23 Internet standard port number for Telnet services Note This option does not display when Hostlist is enabled from the ConnectMode prompt see Connect Mode on page 52 for more information XPort Device Server User Guide 59 7 133BSetup Mode Channel Configuration DisConnMode This setting determines the conditions under which the unit will cause a network connection to terminate DisConnMode 000 _ Notes In DisConnMode Disconnect Mode Modem Control In drop either drops the connection or is ignored All bit positions in the table that are blank represent don t care bits for that particular option which can be set to either a O or 1 value Table 7 10 Disconnect Mode Options Disconnect when
56. error tolerance thereby leading to inconsistent speed settings on the two ends of the serial channel XPort Device Server User Guide 68 8 Setup Mode Advanced Settings Increasing CPU clock speed consumes more power and generates more heat This reduces the maximum operating temperature specification See the appropriate product brief for details Disable Monitor Mode at bootup This option allows you to disable all entries into Monitor Mode during startup except for the xxx sequence This prevents entry using yyy zzz xx1 and yy1 key sequences only during the bootup sequence The default for Monitor Mode at bootup is N No See 11 Monitor Mode Disable Monitor Mode bootup N HTTP Port Number This option allows the configuration of the web server port number The valid range is 1 65535 The default HTTP port number is 80 HTTP Port Number 80 _ SMTP Port Number This option allows the configuration of the email port number The valid range is 1 65535 The default SMTP port number is 25 SMTP Port Number 25 _ Note When configuring the HTTP or SMTP port number take note of the reserved port numbers on page 51 RS 485 TX Enable Active Level Note The following applies to XPort model XP1004000 03 XPort 485 This option allows the selection of the active level either active high or active low for the RS485 TXEN signal The default is active low
57. f the device is DHCP enabled the DHCP server provides the DNS server IP address which will override this configured value Note This setting is applicable only in Manual Connection mode Set DNS Server IP addr N XPort Device Server User Guide 45 6 Setup Mode Server Configuration Change Telnet Web Manager Password Setting the Telnet Web Manager password prevents unauthorized access to the setup menu through a Telnet connection to port 9999 or through web pages The password must have 4 characters Change Telnet Web Manager password N _ An enhanced password setting for Telnet access only of 16 characters is available under Security Settings Option 6 on page 70 Note You do not need a password to access the Setup Mode window by a serial connection DHCP Name If a DHCP server has automatically assigned the IP address and network settings you can discover the unit by using the Devicelnstaller network search feature There are three methods for assigning DHCP names to the unit Default DHCP Name If you do not change the DHCP name and you are using an IP of 0 0 0 0 then the DHCP name defaults to CXXXXXX XXXXXX is the last 6 digits of the MAC address shown on the label on the bottom side of the unit For example if the MAC address is 00 20 4A 12 34 56 then the default DHCP name is C123456 In other words if you do nothing and leave the IP address set to 0 0 0 0 the UDS1100 wil
58. figuration options Accessing Setup Mode Telnet Connection To configure the unit over the network establish a Telnet connection to port 9999 Note You can also use Devicelnstaller to access Telnet Select the device from the main window list and click the Telnet Configuration tab Skip steps 1 and 2 XPort amp Device Server User Guide 40 5 Configuration via Telnet or Serial Port Setup Mode To establish a Telnet connection 1 From the Windows Start menu click Run and type the following command where x x x x is the IP address and 9999 is the unit s fixed network configuration port number Windows telnet x x x x 9999 UNIX telnet x x x x 9999 2 Click OK The following information displays Figure 5 1 MAC Address MAC address 0080A394616D Software version V6 10 0 0RC3 140317 XPTEXE AES library version 1 8 2 1 Press Enter for Setup Mode 3 To enter Setup Mode press Enter within 5 seconds The configuration settings display followed by the Change Setup menu Figure 5 2 Setup Menu Options Change Setup 0 Server 1 Channel 1 3 E mail 5 Expert 6 Security 7 Defaults 8 Exit without save 9 Save and exit Your choice _ 4 Select an option on the menu by entering the number of the option in the Your choice field and pressing Enter 5 To enter a value for a parameter type the value and press Enter or to confirm a current value jus
59. haking HW Flow Control In Allows for flow control on the connection with hardware handshaking Status LED 1 Indicates channel 1 status and extended diagnostics when status LED 3 is lit Status LED 3 Indicates errors and configurations Modem Control In Allows for control of the connection and disconnection of channel 1 Modem Control Out DCD Indicates a connection is established on channel 1 Link Status Indicates the Ethernet link state RS485 Tx Enable Allows for control of the RS485 Tx Output Enable signal This function must be mapped to one of the CPs for the RS485 interface mode to operate correctly 3 When you are finished click the OK button 4 Onthe main menu click Apply Settings Apply Settings 1 To save and apply the configuration changes to the device server click the Apply Settings button Note Clicking OK on each page does not change the configuration on the device Clicking the OK button tells the XPort module what changes to use the Apply Settings button makes the changes permanent and reboots the XPort device server Apply Defaults 1 Click the Apply Defaults button to set the device server back to the default settings For details see Default Settings on page 74 XPort Device Server User Guide 38 4 Configuration Using Web Manager 2 Click Yes to set factory settings or click No to cancel Figure 4 12 Apply Settings and Apply Defaults Xrort LANTRONIX
60. igured in the unit is 129 1 2 3 then an example command string would be C3 7 This would connect to 129 1 2 3 and port 7 You may also use a different ending for the connection string For example C50 1 23 would connect you to 129 1 50 1 and port 23 If an IP address does not follow the first command string character which is C the subsequent character string is interpreted as the host name and domain to be used in DNS lookup This character string can include a destination port number as well The port number can be preceded by either a forward slash or a colon Table 7 7 Manual Connection Address Example Complete override connection is started with host 121 2 4 5 C121 2 4 5 1 port 1 C5 Connects to 129 1 2 5 port 1234 C28 10 12 Connects to 129 1 28 10 port 12 C0 0 0 0 0 Enters Monitor Mode Cwww lantronix com 80 Tries to connect to the Lantronix web server if the lt hostname domain gt www lantronix com is configured in the DNS server database Autostart Automatic If you enable Autostart the unit automatically connects to the Connection remote IP address and remote port specified when the firmware starts Hostlist If you enable this option the device server scrolls through the hostlist until it connects to a device listed in the hostlist table XPort Device Server User Guide 54 7 133BSetup Mode Channel Configuration Once it connects the unit stops trying to c
61. ing local port to change with each connection The port range is 50 000 to 59 999 Each subsequent connection increments the number by 1 it wraps back around to 50 000 XPort Device Server User Guide 51 7 133BSetup Mode Channel Configuration Only use this automatic port increment feature to initiate a connection using TCP Set the port to a non zero value when the unit is in a passive mode or when using UDP instead of TCP Connect Mode Connect Mode defines how the unit makes a connection and how it reacts to incoming connections over the network ConnectMode CO _ Enter Connect Mode options in hexadecimal notation Note All bit positions in the table that are blank represent don t care bits for that particular option which can be set to either a 0 or 1 value Table 7 6 Connect Mode Options a Incoming Connection Never accept incoming Accept with active Modem Control In Always Accept b Response Nothing quiet Character response C connect D disconnect N unreachable BE c Active Startup No active startup With any character With active Modem Control In With a specific start character o 0 een 7J TT j j j lt TT TT Te Pee PTTL d Datagram Type le pt BE RE EEE SES E3 e Modem Mode HZ ee ay XPort Device Server User Guide 52 7 133BSetup Mode Channel Configuration SS nere To T TTS Ta ln ew tede ree
62. is a modem connected to a local PC and a modem connected to a remote machine A user must dial from the local PC to the remote machine accumulating phone charges for each connection Modem Mode allows you to replace modems with XPort modules and to use an Ethernet connection instead of a phone call By not having to change communications applications you avoid potentially expensive phone calls To select Modem Mode set the Connect Mode to C6 no echo D6 echo with full verbose D7 echo with numeric response CF modem responses only numeric response or CE modem responses only full verbose Note If the unit is in Modem Mode and the serial port is idle the unit can still accept network TCP connections to the serial port if Connect Mode is set to C6 no echo D6 echo with full verbose D7 echo with numeric response CF modem responses only numeric response or CE modem responses only full verbose Without Echo In Modem Mode echo refers to the echo of all of the characters entered in command mode it does not mean to echo data that is transferred Quiet Mode without echo refers to the modem not sending an answer to the commands received or displaying what was typed Data Echo amp Modem Full Verbose The unit echoes modem commands and responds Response to a command with a message string shown in the table below Numeric Response The unit echoes modem commands and responds to a command with a numeric response
63. l supply the DHCP name Cxxxxxx to the DHCP server where xxxxxx is the last 6 digits of the MAC address Custom DHCP Name You can create your own DHCP name If you are using an IP address of 0 0 0 0 then the last option in Server configuration is Change DHCP device name This option allows you to change the DHCP name to an alphanumeric name LTX in our example For instance if you type a Y when asked if you want to change the DHCP name you will be prompted for a new DHCP name The example uses LTX as the DHCP name sent to the DHCP server but you can type in anything you want e g Test Lab Accounting Radiology or any other string you want to use Change DHCP device name not set N Y Enter new DHCP device name LTX Numeric DHCP Name You can change the DHCP name by specifying the last octet of the IP address When you use this method the DHCP name is LTXYY where YY is what you chose for the last octet of the IP address If the IP address you specify is 0 0 0 12 then the DHCP name is LTX12 This method only works with 2 digit numbers 01 99 For instance if you specify a two digit number for the last octet of the IP address leaving the first three octets set to 0 then the DHCP name will be the name you provided with that number appended l e if you specify IP address 0 0 0 43 and change the DHCP name to Test Lab the name the UDS1100 sends to the DHCP server will be Test Lab43 Note that this has no effect on
64. layed in parentheses Recipient 2 _ Trigger 1 A trigger event occurs when the unit receives the specified trigger input because of a specified combination of conditions on the configurable pins Enable serial trigger input N Trigger inputl A I X X m rigger inputl A I X X Trigger inputl A I X X Message Priority L Minimum notification interval 1 s Re notification interval 0 s Set the configurable pins to A Active I Inactive or X Don t Care Active can mean active low or active high If the configurable pins are all set to b Don t Care then they are disabled If both the serial sequence and the configurable pins are disabled the trigger is disabled To change the configurable pins settings send setup records to Port 77FE Message The subject line of the trigger event email to the specified recipient s Priority The priority level for the trigger even email Enter L for normal priority or H for high priority Minimum notification interval The minimum time allowed between individual triggers If a trigger event occurs within the minimum interval since the last trigger it is ignored XPort Device Server User Guide 66 8 Setup Mode Advanced Settings Re notification interval Indicates the time interval at which a new email message is sent to the recipient s when a single trigger event remains active
65. n Settings TCP To configure a channel s TCP settings 1 On the main menu click Connection The Connection Settings window for the channel displays XPort amp Device Server User Guide 30 4 Configuration Using Web Manager Figure 4 7 TCP Connection Settings Connection Settings Channel 1 Connect Protocol Protocol TCP v Connect Mode Passive Connection Active Connection Accept Incoming Yes v Active Connect None v Password j Required Oves No Start Character ox in Hex Password Modem Mode None v Modem Escape Sequence Pass Show IP Address After Mrd Througn es Ono RING Ces O Ne Endpoint Configuration Local Port 10001 CI Auto increment for active connect Remote Port D Remote Host 0 0 0 0 Common Options Telnet Com Port Cntr Disable v Connect Response None v F Use jp Terminal Name Hostlist Oys No LED Blink Disconnect Mode On Mdm Ctrl In Drop Oves 9 No Hard Disconnect S Yes Ono Check EOT Ctrl D O Yes 9 No Inactivity Timeout mins secs XPort amp Device Server User Guide 31 4 Configuration Using Web Manager 2 Inthe available fields enter or modify the following information Connect Protocol Protocol From the drop down menu select TCP Connect Mode Passive Connection Accept
66. n the XPort module TCP Keepalive Non configurable field Displays 1 65s the XPort device server s TCP keepalive value The default setting is 45 Telnet Supported Non configurable field Indicates if Telnet sessions Telnet Port Non configurable field Displays the XPort module s port for Telnet sessions Web Port Non configurable field Displays the XPort device server s port for Web Manager configuration Maximum Baud Rate Supported Non configurable field Displays the XPort module s maximum baud rate Note the XPort unit may not currently be running at this rate Firmware Upgradeable Non configurable field Displays True indicating the XPort module s firmware is upgradeable as newer version become available Supports Configurable Pins Non configurable field Displays True indicating configurable pins are available on the XPort device server Supports Email Triggers Non configurable field Displays True indicating email triggers are available on the XPort module Supports AES Data Stream Non configurable field Displays True if the XPort unit certain part numbers supports AES encryption Supports 485 Non configurable field Displays True XPort module supports the RS 485 protocol Supports 921K Baud Rate Non configurable field Displays True XPort device server supports baud rates up to 921600 bits per second bps Supports HTTP Server Non configur
67. ng binary value to a hexadecimal representation Converting Binary to Hexadecimal Following are two simple ways to convert binary numbers to hexadecimals Conversion Table Hexadecimal digits have values ranging from 0 to F which are represented as 0 9 A for 10 B for 11 etc To convert a binary value for example 0100 1100 to a hexadecimal representation the upper and lower four bits are treated separately resulting in a two digit hexadecimal number in this case 4C Use the following table to convert values from binary to hexadecimal Scientific Calculator Another simple way to convert binary to hexadecimals is to use a scientific calculator such as the one available on Windows operating systems For example 1 On the Windows Start menu click Programs Accessories Calculator 2 Onthe View menu select Scientific The scientific calculator displays 3 Select Bin Binary and type the number to convert XPort Device Server User Guide 92 B Binary to Hexadecimal Conversions 4 Click Hex The hexadecimal value displays Server User Guide XPort Device C Compliance RoHS Notice All Lantronix products in the following families are China RoHS compliant and free of the following hazardous substances and elements Lead Pb Mercury Hg Polybrominated biphenyls PBB Cadmium Cd Li Hexavalent Chromium Cr VI Product Family Name Toxic or hazardous Substances and Eleme
68. ngs Option 6 70 Disable SNMP 71 SNMP Community Name 71 Disable Telnet Setup 71 Disable TFTP Firmware Upgrade 71 Disable Port 77FE Hex 71 77FEh Access Mode 72 Disable Web Server 72 Disable Web Setup 72 Disable ECHO Ports 72 Enable Encryption 72 Enable Enhanced Password 74 Disable Port 77F0 Hex 74 Default Settings Option 7 74 Channel 1 Configuration Defaults 74 Expert Settings Defaults 75 Security Settings Defaults 75 Email Settings 76 XPort Device Server User Guide 7 Table of Contents 9 GPIO Interface 77 Configurable Pins 77 Features TI Control Protocol 77 Guidelines 78 Commands 78 Examples 81 10 Firmware Upgrades 82 Obtaining Firmware 82 Reloading Firmware 82 Using TFTP Graphical User Interface 82 Using TFTP Command Line Interface 83 Recovering the Firmware Using the Serial Port and Devicelnstaller 84 11 Monitor Mode 85 Entering Monitor Mode Using the Serial Port 85 Entering Monitor Mode Using the Network Port 85 Monitor Mode Commands 85 12 Troubleshooting 88 Problems and Error Messages 88 A Lantronix Technical Support 91 B Binary to Hexadecimal Conversions 92 Converting Binary to Hexadecimal 92 Conversion Table 92 Scientific Calculator 92 G Compliance 94 RoHS Notice 94 XPort Device Server User Guide 8 List of Figures Figure 2 1
69. ns Send No parameters Response 1 parameter Bytes 1 4 Directions Bit X 1 means GPIO X is an output 0 means it is an input Command 12h Get Active Levels Send No parameters Response 1 parameter Bytes 1 4 Active levels Bit X 1 means GPIO X is active low 0V when active 3 3V when inactive 0 means it is active high 3 3V when active OV when inactive Command 13h Get Current States Send No parameters Response 1 parameter Bytes 1 4 States Bit X 1 means GPIO X is active 0 means it is inactive XPort amp Device Server User Guide 79 Command 19h Set Directions Send 2 parameters Bytes 1 4 Mask Bit X 1 means the direction for GPIO X will be updated with the value in the second parameter 0 means the direction for that GPIO will not change Bytes 5 8 New Directions Bit X 1 means GPIO X will become an output 0 means it will become an input Response 1 parameter Bytes 1 4 The updated directions Command 1Ah Set Active Levels Send 2 parameters Bytes 1 4 Mask Bit X 1 means the direction for GPIO X will be updated with the value in the second parameter 0 means the active type for that GPIO will not change Bytes 5 8 New Active Levels Bit X 1 means GPIO X will become active low 0 means it will become active high Response 1 parameter Bytes 1 4 Updated active levels Command 1Bh Set States Send 2 parameters Bytes 1 4 Mask Bit X 1 means the state for GPIO X will be updated wi
70. nt don t care bits for that particular option which can be set to either a 0 or 1 value Table 7 11 Flush Mode Options Input Buffer Serial to Network Ciar vith a connection initisted trom the device to e network PI Clear with a connection ini ated from the network to the deve t Clear when the network connection to or from the device is disconnected 1 Output Buffer Network to Serial Clear with a connection inifated from the devioe to ne newek T Clesrwih a connection initisted trom the network tothe devo 4 Clear when the network connection to or from the device is disconnected Alternate Packing Algorithm Pack Control Ai Pack Control The packing algorithms define how and when packets are sent to the network The standard algorithm is optimized for applications in which the unit is used in a local environment allowing for very small delays for single characters while keeping the packet count low The alternate packing algorithm minimizes the packet count on the network and is especially useful in applications in a routed Wide Area Network WAN Adjusting parameters in this mode can economize the network data stream Pack control settings are enabled in Flush Mode Set this value to 00 if you do not need specific functions Note All bit positions in the table that are blank represent don t care bits for th
71. nts Lead Mercury Cadmium Hexavalent Polybrominated Pb Hg Cd Chromium Cr biphenyls PBB DSC EDS IntelliBox MatchPort Micro MSS100 PremierWave SCS SecureBox SLB SLC SLP Spider and Spider Duo UBox UDS1100 and 2100 WiBox WiPort xDirect xPico XPort XPress DR amp XPress DR xPrintServer xSenso O toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 ojojojojojojojojoj ojojojojojojojojojojojojo ojojojojojojojojoj ojojojojojojojojojojojojo o o e Polybrominated diphenyl ethers PBDE Polybrominated diphenyl ethers PBDE X toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 XPort Device Server User Guide 94
72. of the web server port number The valid range is 1 65535 The default port is 80 Config Server Port Not applicable for this product MTU Size The Maximum Transmission Unit MTU is the largest physical packet size a network can transmit for TCP and UDP Enter between 512 and 1400 bytes The default is 1400 bytes TCP Re transmission timeout ms The desired TCP re transmission timeout value If the ACK is not received for a packet sent from the XPort device then the unit will retransmit the data The valid range is 500 4000 msec 3 When you are finished click the OK button 4 Onthe main menu click Apply Settings Host List Configuration The XPort module scrolls through the host list until it connects to a device listed in the host list table After a successful connection the unit stops trying to connect to any others If this connection fails the unit continues to scroll through the table until the next successful connection The host list supports a minimum of 1 and a maximum of 12 entries Each entry contains an IP address and a port number Note The host list is disabled for Manual and Modem Mode The unit does not accept a data connection from a remote device when the hostlist option is enabled XPort Device Server User Guide 26 4 Configuration Using Web Manager To configure the XPort module s host list 1 On the main menu click Hostlist Figure 4 5 Hostlist Setting
73. ol interface Disable Port 77F0h _ Default Settings Option 7 Select 7 to reset the unit s Channel 1 configuration email settings and expert settings to the default settings The server configuration settings for IP address gateway IP address and netmask remain unchanged The configurable pins settings also remain unchanged The specific settings that this option changes are listed below Channel 1 Configuration Defaults Baudrate 9600 I F Mode 4C 1 stop bit no parity 8 bit RS 232C Flow 00 Port number 10001 Connect Mode CO always accept incoming connection no active connection startup Send in Modem Mode Enabled Show IP addr after RING Enabled Auto increment source port Disable Hostlist retry counter 3 XPort Device Server User Guide 74 8 Setup Mode Advanced Settings Hostlist retry timeout 250 msec Start character for serial channel 1 OxOD CR All other parameters 0 Expert Settings Defaults TCP Keepalive time ins 45 ARP Cache timeout in s 600 CPU Performance 0 Regular Disable Monitor Mode bootup No RS485 tx enable active low HTTP Port Number 80 1 65535 SMTP Port Number 25 1 65535 MTU Size 512 1400 0 resulting in an operational value of 1400 TCP Re transmission Timeout 500 4000 500 ms Alternate MAC Disabled for OEM use only Ethernet Connection Type 0
74. om the device server See the full list of Connect Mode options in Connect Mode Make sure that port 30718 77FEh is not blocked with any router that you are using on the network Also make sure that port 77FEh is not disabled within the Security settings of the device server XPort amp Device Server User Guide 90 A Lantronix Technical Support Lantronix offers many resources to support our customers and products at http www lantronix com support For instance ask a question find firmware downloads access the FTP site and search through tutorials FAQs bulletins warranty information extended support services and product documentation To contact technical support or sales look up your local office at http www lantronix com about contact html When you report a problem please provide the following information Your name company name address and phone number Lantronix product and model number Lantronix MAC number or serial number Firmware version and current configuration Description of the problem Status of the unit when the problem occurred please try to include information on user and network activity at the time of the problem XPort Device Server User Guide 91 B Binary to Hexadecimal Conversions Many of the unit s configuration procedures require assembling a series of options represented as bits into a complete command represented as a byte Convert the resulti
75. onnect to any others If this connection fails the unit continues to scroll through the table until it is able to connect to another IP in the hostlist Hostlist supports a minimum of 1 and a maximum of 12 entries Each entry contains the IP address and the port number The hostlist is disabled for Manual and Modem Modes The unit does not accept a data connection from a remote device when the hostlist option is enabled Figure 7 2 Apply Settings and Apply Defaults Baudrate 9688 I F Mode 4C Flow 88 Port No 18881 ConnectMode 25 Send in Modem Mode lt Y Auto increment source port lt N Hostlist i IP 172 019 000 001 Port 80823 g2 IP 172 019 000 002 Port 83881 83 IP 172 019 000 003 Port 16061 Change Hostlist ND V gi IP address 41725 19 gt 888 5 CH881 5 Port lt 23 82 IP address 1725 H8195 0 882 Port 3881 g3 IP address 1725 H8195 888 5 C883 5 Port 188815 B4 IP address 8808 6 gt COBB5 CHBB Hostlist Bi IP 172 619 966 961 Port 88823 82 IP 172 619 966 962 Port 83881 gg IP 172 019 000 093 Port 1080881 Change Hostlist CN N Hostlist Retrycounter lt 3 Hostlist Retrytimeout lt 250 gt DisConnMode 88 FlushMode 808 DisConnTime 88 88 SendChar i lt 00 SendChar 2 lt 88 To enable the hostlist 1 Enter a Connect Mode of 0x2
76. ons Lantronix address updated DeviceLinx and XPort trademark information updated May 2012 Updated for 6 8 release Added information for advanced password support and removed XChip information February 2013 6 9 0 2 Updated part number and MAC address information Updated Web Manager and Devicelnstaller content August 2014 6 10 0 0 Updated for version 6 10 of the firmware New monitor mode command to show full firmware release version November 2014 6 10 0 1 New security settings command for 77FEh Access Mode New monitor mode command to show flash write counts For the latest revision of this product document please check our online documentation at www lantronix com support documentation i i August 2008 Revised for version 6 6 of the firmware i i If you use a previous version of the firmware go to the Lantronix FTP site at ftp ftp lantronix com pub to find the earlier documentation XPort Device Server User Guide 3 Table of Contents Intellectual Property 2 Warranty 2 Contacts 2 Disclaimer 2 Revision History 3 List of Figures 9 List of Tables 9 Using This Guide 10 Purpose and Audience 10 Chapter Summary 10 Additional Documentation 11 Introduction 12 Capabilities 12 Applications 12 Protocol Support 13 Configuration Methods 13 Addresses and Port Numbers 13 Hardware Address 13 IP Address 14 Port Numbers 14 Product
77. ors quickly without having to contact a dealer or Lantronix It helps to connect a terminal to the serial port while diagnosing an error to view summary messages that may display When troubleshooting always ensure that the physical connections power cable network cable and serial cable are secure Note Some unexplained errors might be caused by duplicate IP addresses on the network Make sure that your unit s IP address is unique When troubleshooting the following problems make sure that the XPort module is powered up Confirm that you are using a good network connection When you issue the ARP S command in Windows the ARP entry addition failed 5 message displays When you attempt to assign an IP address to the unit by the ARP method the Press Enter to go into Setup Mode error described below message displays Now when you Telnet to the device server the connection fails When you Telnet to port 9999 the Press Enter to go into Setup Mode message displays However nothing happens when you press Enter or your connection is closed When you Telnet to port 1 to assign an IP address to the device server the Telnet window does not respond for a long time Problems and Error Messages Your currently logged in user does not have the correct rights to use this command on this PC When you Telnet to port 1 on the device server you are only assigning a temporary IP address When you Telnet into port
78. ote If you choose to disable this option keep in mind that disabling both Telnet Setup and Port 77FE will prevent users from accessing the setup menu from the network This setting defaults to the N No option The Y Yes option disables access to Setup Mode by Telnet port 9999 It only allows access locally using the web pages and the serial port of the unit Disable Telnet Setup N Disable TFTP Firmware Upgrade This setting defaults to the N No option The Y Yes option disables the use of TFTP to perform network firmware upgrades With this option you can download firmware upgrades over the serial port using Devicelnstaller s Recover Firmware procedure See 10 Firmware Upgrades Disable TFTP Firmware Update N Disable Port 77FE Hex Note If you choose to disable this option keep in mind that disabling both Telnet Setup and Port 77FE will prevent users from accessing the setup menu from the network Port 77FE is a setting that allows Devicelnstaller Web Manager and custom programs to configure the unit remotely You may wish to disable this capability for security purposes XPort Device Server User Guide 71 8 Setup Mode Advanced Settings Disable Port 77FEh N _ The default setting is the N No option which enables remote configuration You can configure the unit by using Devicelnstaller web pages Telnet or serial configuration The Y Yes option disables rem
79. ote configuration and web sites Note The Y Yes option disables many of the GUI tools for configuring the unit including the embedded Web Manager tool 77FEh Access Mode Configuring this setting is available if port 77FE is enabled This option will not be listed if port 77FE is disabled Set 0 for Read amp Write mode and 1 for Read Only mode Default value of this setting is Read Write 0 If access mode is Read only then read operation can be done through port 77FE if Read Write access is selected then both read and write of data can be done through port 77FE 77FEh Access Mode 0 Read amp Write 1 Read Only 0 Disable Web Server This setting defaults to the N option The Y Yes option disables the web server Disable Web Server N Disable Web Setup The Y Yes option disables configuration using the Web Manager This setting defaults to the N option Disable Web Setup N Disable ECHO Ports This setting controls whether port 7 echoes characters it receives Disable ECHO ports Y Enable Encryption Rijndael is the block cipher algorithm chosen by the National Institute of Science and Technology NIST as the Advanced Encryption Standard AES to be used by the US government The XPort module supports 128 192 and 256 bit encryption key lengths XPort Device Server User Guide 72 8 Setup Mode Advanced Settings Note Configuring encryption should be
80. pe 0 Security Settings Option 6 Note You can change security settings by means of Telnet or serial connections only not on the Web Manager We recommend that you set security over the dedicated network or over the serial setup to prevent eavesdropping CAUTION Disabling both Telnet Setup and Port 77FE will prevent users from accessing the setup menu from the network Disabling Port 77FE also disables the Web from configuring the device Select 6 to configure security settings Figure 8 3 Security Settings Disable SNMP N _ SNMP Community Name _ Disable Telnet Setup N Disable TFTP Firmware Update N Disable Port 77FEh N _ 77FEh Access Mode 0 Read amp Write 1 Read Only 0 Disable Web Server N Disable Web Setup N XPort Device Server User Guide 70 8 Setup Mode Advanced Settings Disable ECHO ports Y Enable Encryption N Enable Enhanced Password N _ Disable Port 77F0h N _ Disable SNMP This setting allows you to disable the SNMP protocol on the unit for security reasons Disable SNMP N _ SNMP Community Name The SNMP Community Name is a required field for NMS to read or write to a device Enter a string of 1 to 13 characters SNMP Community Name public _ The default entry is public The current value is displayed in parentheses Disable Telnet Setup N
81. pt05 61000 rom X9 tftp i 192 168 1 111 put xpt webm 2005 cob WEBI For XPort 03 and XPort 04 modules tftp i 192 168 1 111 put xpt05 61000 rom X9 tftp i 192 168 1 111 put xpt webm 2005 cob WEBI XPort amp Device Server User Guide 83 Recovering the Firmware Using the Serial Port and Devicelnstaller If for some reason the firmware is damaged you can recover the firmware file by using Devicelnstaller to download the ROM file over the serial port To recover firmware 1 Start Devicelnstaller If your PC has more than one network adapter a message displays Select an adapter and click OK 2 From the Tools menu select Recover Firmware The Serial Port Firmware Recovery window displays 3 For Port on PC enter the COM port on the PC that is connected to the serial port of the Lantronix unit 4 For Device Model be sure the appropriate XPort device is shown XPort 03 04 or XPort 05 modules 5 ForFirmware File click the Browse button and go to the location where the firmware file resides Note Make sure the XPort module on which you are recovering firmware is connected to this selected port on your PC 6 Click OK to download the file 7 When prompted reset the device Status messages and a progress bar at the bottom of the screen show the progress of the file transfer When the file transfer completes the message Successful Click OK to Close appears 8 Click the OK button to
82. ress If you do not enter the IP address the command is executed locally Note All commands must be in capital letters Responses to some of the commands are in Intel Hex format XPort amp Device Server User Guide 85 Table 11 1 Monitor Mode Commands ARP Table Shows the unit s ARP table entries Set IP address Example hostbits gateway co 192 168 0 10 8 192 168 0 1 10001 192 168 1 10 and DNS server IP with 192 168 0 10 IP address of the XPort module 8 number of hostbits 192 168 0 1 gateway IP address 10001 port number of the XPort module 192 168 1 10 IP address of the DNS Server The XPort device server stores the setup and performs a reset It sends an X before the reset if the command was OK Get configuration Gets a memory page of configuration information from memory page from the device Get Configuration Gets configuration of unit with IP address x x x x as hex records 120 bytes Get MAC address Shows the unit s 6 byte MAC address Network Connection Shows the unit s IP address gateway subnet mask and DNS server Network Status Reports the network interfaces statuses Includes potentially negotiated parameters like speed duplex for Ethernet or BSSID encryption authentication for wireless interfaces Pings unit with IP address x x x x to check device status Exits diagnostics mode Set configuration to Sets a memory page of configuration information memory page on the device S
83. rs of four bytes each Command Parameter 1 Parameter 2 0 1 2 3 4 5 6 7 8 On some commands one or all parameters are ignored For UDP command type and parameters need to be in the same datagram Responses to valid commands are always five bytes long consisting of the returned command byte and as parameters in the current or updated values In case of an invalid command only one byte with value OFFh is returned Command Parameter 1 0 1 2 3 4 When sending a command TCP and UDP wait for the response before sending the next command Commands Byte 0 Command Types 10h Get functions 11h Get directions input or output 12h Get active levels high active or low active 13h Get current states active or not active 19h Set directions 1Ah Set active levels 1Bh Set current states There is no Set functions command Since the pin s function depends on the hardware in which the XPort unit is embedded that configuration is only allowed using 77FE Settings changed by any of the Set commands are not stored and are lost when the unit is powered down or rebooted XPort Device Server User Guide 78 Command 10h Get Functions Send No parameters Response 1 parameter Bytes 1 4 Functions Bit X 1 means general purpose I O available to the user 0 means dedicated function e g serial flow control diagnostics for configurable pin X Command 11h Get Directio
84. rt module 11 Monitor Mode Provides instructions for accessing and using the command line interface for monitoring the network and diagnosing problems 12 Troubleshooting Describes common problems and error messages and how to contact Lantronix Technical Support A Lantronix Technical Support Provides contact information for Lantronix and other technical support options B Binary to Hexadecimal Provides instructions for converting binary numbers to Conversions hexadecimals C Compliance Provides RoHS compliance information Additional Documentation Visit the Lantronix Web site at www lantronix com support documentation for the latest documentation and the following additional documentation XPort Device Server Integration Provides information about the XPort module hardware testing Guide the XPort device server using the demonstration board and integrating the XPort device into your product XPort Universal Demo Board Provides the steps for getting the XPort module demonstration Quick Start board up and running XPort Universal Demo Board Provides information for using XPort module on the demo User Guide board Devicelnstaller Online Help Provides information on using Devicelnstaller to configure IP addresses and locate Lantronix devices on the network Com Port Redirector User Provides information on using the Lantronix Windows based Guide utility to create secure virtual com port XPort Device Server User
85. s Hostlist Settings Retry Settings Retry Counter 3 Retry Timeout 250 Host Information Host Address Host Address 0 0 0 0 2 0 0 0 0 0 0 0 0 t 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 ji 0 0 0 0 0 0 0 0 Jji 0 0 0 0 0 0 0 0 i 0 0 0 0 2 Enter or modify the following fields Retry Settings Retry Counter Enter the value for the number of times the XPort device server should attempt to retry connecting to the host list Retry Timeout Enter the duration in milliseconds the XPort unit should abandon attempting a connection to the host list Host Information Host Address Enter or modify the host s IP address Port Enter the target port number 3 When you are finished click the OK button 4 On the main menu click Apply Settings Channel 1 Configuration The Channel 1 configuration defines how the serial port responds to network and serial communication XPort Device Server User Guide 27 4 Configuration Using Web Manager Serial Settings To configure the channel s serial settings 1 On the main menu click Serial Settings under Channel 1 to display the Serial Settings window Figure 4 6 Channel Serial Settings Serial Settings hannel 1 Disable Serial Port Port Settings Protocol RS232 Flow Control None Pack Control Match Bytes Flush Mode Flush Input Buffer
86. sent XPort Device Server User Guide 62 7 133BSetup Mode Channel Configuration DisConnTime Inactivity Timeout Use this parameter to set an inactivity timeout The unit drops the TCP connection to the local port if there is no activity on the serial line before the set time expires Enter time in the format mm ss where m is the number of minutes and s is the number of seconds DisConnTime 0 0 To disable the inactivity timeout enter 00 00 Range is 0 disabled to 5999 seconds 99 minutes 59 seconds Default is 0 Send Characters Enter up to two characters in hexadecimal representation in sendchar SendChar 1 0 SendChar 2 0 If the unit receives a character on the serial line that matches one of these characters it sends the character immediately along with any awaiting characters to the TCP connection This action minimizes the response time for specific protocol characters on the serial line for example ETX EOT Setting the first sendchar to 00 disables the recognition of the characters Alternatively the unit can interpret two characters as a sequence see Pack Control on page 67 Telnet Terminal Type This parameter displays only if you enabled the terminal type option in Disconnect Mode With this option enabled you can use the terminal name for the Telnet terminal type Enter only one name With terminal type option enabled the unit also reacts to the EOR en
87. sign is not on your logical subnet The device server may not be plugged into the network properly The cause is most likely one of the following The hardware address you specified is incorrect The IP address you are trying to assign is not a valid IP for your logical subnet You did not choose the correct subnet mask The most likely reason is the wrong serial settings were chosen The issue is most likely something covered in the previous problem or possibly you have Caps Lock on There may be an IP address conflict on your network You are not Telneting to port 9999 The Telnet configuration port 9999 is disabled within the device server security settings Confirm that your PC has an IP address and that it is in the same logical subnet that you are trying to assign to the device server Make sure that the Link LED is lit If the Link LED is not lit then the device server is not properly plugged into the network Double check the parameters that you specified Note You cannot assign an IP address to a device server through a router The serial settings for the serial device and the device server must match The default serial settings for the device server are RS 232 9600 baud 8 character bits no parity 1 stop bit no flow control Double check everything in the problem above Confirm that Caps Lock is not on Turn the device server off and then issue the following commands
88. sing Devicelnstaller XPort Device Server User Guide 17 3 Using Devicelnstaller DHCP Device Name Non configurable field Displays the name associated with XPort module s current IP address if the IP address was obtained dynamically To change the DHCP device name see Configuration Using Web Manager or Configuration via Telnet or Serial Port Setup Mode Group Configurable field A group name to categorize the XPort device server Double click the field type in the value and press Enter to complete This group name is not visible on other PCs or laptops using Devicelnstaller Comments Configurable field Information about the XPort module Double click the field type in the value and press Enter to complete This description or comment is not visible on other PCs or laptops using Devicelnstaller Device Family Non configurable field Displays the XPort module s device family as XPort device server Type Non configurable field Displays the device type as XPort 03 04 or XPort 05 device servers ID Non configurable field Displays the XPort module s ID embedded within the box Hardware Address Non configurable field Displays the XPort unit s hardware or MAC address Firmware Version Non configurable field Displays the firmware currently installed on the XPort module Extended Firmware Version Non configurable field Displays the full version
89. t Channel 1 a 3 Serial Settings Firmware Version V6 10 0 1 Connection Build Date 23 Oct 2014 Email Network Sett Tigger t MAC Address 00 80 A3 94 61 6E Trigger 2 Trigger 3 Network Mode Wired Configurable Pins DHCP HostName lt None gt Apply Settings IP Address 172 19 100 65 Default Gateway 172 19 0 1 DNS Server 172 19 1 1 Apply Defaults MTU 1400 RS232 9600 8 None 1 None The main menu is in the left pane of the Web Manager window XPort Device Server User Guide 21 4 Configuration Using Web Manager Network Configuration The unit s network values display when you select Network from the main menu The following sections describe the configurable parameters on the Network Settings page Figure 4 3 Network Settings Network Settings Network Mode Wired Only IP Configuration Obtain IP address automatically Auto Configuration Methods BOOTP Enable X Disable DHCP Enable Disable AutolP Enable Disable DHCP Host Name Use the following IP configuration IP Address 172 19 205 3 Subnet Mask 0 0 0 0 Default Gateway 172 119 0 1 DNS Server 0 0 0 0 Ethernet Configuration Auto Negotiate Speed 100Mbps X 10Mbps Duplex Full Half Network Mode 1 Click Network from the main menu 2 Note the following Network Mode Wired Only is the only choice It enables the Ethernet network connectivity Automa
90. t press Enter 6 When you are finished save the new configuration option 9 The unit reboots XPort Device Server User Guide 41 5 Configuration via Telnet or Serial Port Setup Mode Serial Port Connection To configure the unit through a serial connection 1 Connect a console terminal or PC running a terminal emulation program to your unit s serial port 2 Setthe terminal emulator serial port settings to 9600 baud 8 bits no parity 1 stop bit no flow control Note The XPort module always uses these serial port settings on boot up 3 Resetthe XPort unit by cycling the unit s power turning the power off and back on Immediately upon resetting the device enter three lowercase x characters xxx Note The easiest way to enter Setup Mode is to hold down the x key at the terminal or emulation while resetting the unit You must do this within three seconds of resetting the XPort module At this point the screen display is the same as when you use a Telnet connection To continue go to step 4 above in the section Telnet Connection Exiting Setup Mode To exit setup mode You have two options To save all changes and reboot the device select option 9 Save and exit from the Change Setup menu All values are stored in nonvolatile memory To exit the configuration mode without saving any changes or rebooting select option 8 Exit without save from the Change Setup menu XPort Device Server
91. th the value in the second parameter 0 means the state for that GPIO will not change Bytes 5 8 New States Bit X 1 means GPIO X will become active 0 means it will become inactive Response 1 parameter Bytes 1 4 Updated states XPort Device Server User Guide 80 Examples Example 1 PC sends command 10h to find out which configurable pins are available as GPIO PC gt XPort 10h 00h 00h 00h 00h 00h 00h 00h 00h XPort gt PC 10h 03h 00h 00h 00h Command details 10h command 10h 00h 00h 00h 00h ignored 00h 00h 00h 00h ignored Response details 10h response to command 10h 03h 00h 00h OOh bits 0 and 1 are 1 2 CP1 and CP2 are configured as GPIOs bit 2 is 0 CP3 is configured as either serial control or diagnostics The other bits are ignored because there are only three configurable pins on the XPort module Example 2 PC sends command 1Bh to change the current states of GPIO 0 and 1 PC gt XPort 1Bh 01h 00h 00h 00h 00h 00h 00h 00h XPort gt PC 1Bh 05h 00h 00h 00h Command details 1Bh command 1Bh 01h 00h 00h 00h the mask that determines which GPIOs will be changed bit 0 is 1 GPIOO will be changed bit 1 is 0 gt GPIO1 will remain the same 00h 00h 00h 00h the new states bit 0 is 0 GPIOO will become 0 bit 1 is ignored since it is masked out Response details 1Bh response to command 1Bh 05h 00h 00h 00h bit 0 is 1
92. the IP address assigned to the UDS1100 by the DHCP server itis only a method to add a two digit number to the DHCP name specified XPort Device Server User Guide 46 6 Setup Mode Server Configuration If the DHCP server is configured to work with a DDNS Dynamic Domain Name Server then the DHCP name supplied by the UDS1100 can also be used as a DNS host name on your network Enable DHCP FQDN Option A fully qualified domain name FQDN is the complete domain name for your device in network The FQDN consists of two parts the hostname and the domain name For example an FQDN for your device might be myxport lantronix com The hostname is myxport and the host is located within the domain lantronix com The option to enable DHCP FQDN becomes available if DHCP is enabled Enable DHCP FQDN option N XPort Device Server User Guide 47 7 Setup Mode Channel Configuration This chapter explains how to configure the serial port Channel 1 Option 1 Select Channel 1 option 1 from the Change Setup menu to define how the serial port responds to network and serial communications The following sections describe the configurable parameters within the Channel configuration menu Figure 7 1 Serial Port Parameters Baudrate 9600 I F Mode 4C Flow 00 Port No 10001 ConnectMode C0 Send in Modem Mode Y Show IP addr after RING Y Auto increment source port N Remote
93. the IP address of the remote device Use Broadcast Select to broadcast the UDP datagram The default is not to XPort Device Server User Guide 34 4 Configuration Using Web Manager broadcast Note Datagrams are sent as subnet directed broadcasts Device Address Table The table is enabled when Datagram Type is set to FD Enter values between 1 and 255 to identify units on the local network of device servers Note Lantronix Tech Support supports Datagram type 01 Datagram Type FD is for OEM use 3 When you are finished click the OK button 4 On the main menu click Apply Settings Email Configuration The unit sends an email to multiple recipients when a specific trigger event occurs There are three separate triggers based on any combination of the configurable pins selected as user I O functions Optionally use a two byte serial string to initiate a trigger Each trigger is independent of the others Each condition within an individual trigger must be met before the unit will send the email To configure the XPort module s email settings 1 On the main menu select Email The Email Settings window opens Figure 4 9 Email Settings Server IP Address 0 0 0 0 Domain Name Email Settings Server Port 25 Unit Name Recipients Recipient 1 Email Address Recipient 2 Email Address 2 Configure the following fields
94. the fields that become available Speed The speed of data transmission The default is 100 Mbps Duplex The direction of data transmission The default is Full 3 When you are finished click the OK button 4 Onthe main menu click Apply Settings XPort amp Device Server User Guide 24 4 Configuration Using Web Manager Server Configuration The unit s server values display when you select Server from the main menu The following sections describe the configurable parameters on the Server Settings page Figure 4 4 Server Settings Server Settings Server Configuration Enhanced Password Enable Disable Telnet Web Manager Password Retype Password Advanced ARP Cache Timeout secs TCP Keepalive secs 45 600 Monitor Mode Bootup 9 Enable Disable CPU Performance Mode Low Regular O High HTTP Server Port 8 Config Server Port MTU Size 1400 TCP Re transmission timeout ms 500 To configure the XPort module s device server settings 1 On the main menu click Server 2 Configure or modify the following fields Server Configuration Enhanced Password Select whether to enable enhanced password Enable selecting this option enables advanced password creation allowing you to create passwords up to 16 bytes in length Disable selecting this option disables advanced p
95. tic IP Address Configuration An IP address can be assigned automatically You then enter related network settings To assign an IP address automatically 1 Onthe main menu click Network 2 Select Obtain IP address automatically XPort Device Server User Guide 22 4 Configuration Using Web Manager 3 Enter the following as necessary BOOTP Select Enable to permit the Bootstrap Protocol BOOTP server to assign the IP address from a pool of addresses automatically Enable is the default DHCP Select Enable to permit the Dynamic Host Configuration Protocol DHCP to assign a leased IP address to the XPort unit automatically Enable is the default AutolP Select Enable to permit the XPort module to generate an IP in the 169 254 x x address range with a Class B subnet Enable is the default DHCP Host Name Enter the desired host name for the XPort unit Note Disabling BOOTP DHCP and AutolP all three checkboxes is not advised as the only available IP assignment method will then be ARP or serial port 4 When you are finished click the OK button 5 On the main menu click Apply Settings Static IP Address Configuration You manually assign an IP address to the unit and enter related network settings To assign an IP address manually 1 On the main menu click Network 2 Select Use the following IP configuration 3 Enter the following as necessary IP Address
96. ts depending on the model of your XPort unit Hardware Address for XPort 05 00 80 A3 Hardware Address for XPort 03 and XPort 04 00 20 4A Note Make note of the MAC address It is needed to locate the XPort module using Devicelnstaller XPort Device Server User Guide 13 2 Introduction IP Address Every device connected to an IP network must have a unique IP address This address is used to reference the specific unit The XPort is automatically assigned an IP address on DHCP enabled networks as it is DHCP enabled by default Port Numbers Every TCP connection and every UDP datagram is defined by a destination IP address and a port number For example a Telnet application commonly uses port number 23 A port number is similar to an extension on a phone system The unit s serial channel port can be associated with a specific TCP UDP port number Port number 9999 is reserved for access to the unit s Setup configuration Mode window Ports 0 1024 are reserved as well For more information on reserved port numbers see to Table 7 5 Reserved Port Numbers on page 57 Product Information Label The product information label on the unit contains the following information about the specific Part Number Revision Manufacturing Date Code Country of Origin Manufacturing Location ID MAC Address Serial Number Barcode MAC Address Serial Number XPort Device Server User Guide 14 2 Introduction

Download Pdf Manuals

image

Related Search

Related Contents

Descargar - GHSports  Installation Bedienung Wartung  MANUEL D`UTILISATION  Samsung NS240 Priručnik za korisnike  9T1159_Flyer Serenium 5  Manual - Control Company  MODE D`EMPLOI  Logicube OmniSAS™ User`s Manual  Manual d`usuari - Web de Educación de la ONCE  GSW Gas Fired Water Heater User's Manual  