1. after approx 5 seconds indicated by green LED Release LEARN button To set the number from 10 gt press LEARN button to select the number of tens required green LED indicates number of tens from 10 to 60 Each press of the button is indicated with a short blink The interval between each press of the button may not exceed 3 seconds If no button is pressed for approx 5 seconds the controller will switch to number setting mode indicated by red LED Press LEARN button to select the number of ones required red LED indicates number of ones selected from 1 to 9 Each press of the button is indicated with a short blink The interval between each press of the button may not exceed 3 seconds If no button is pressed for approx 5 seconds the controller will exit the setting mode The number is confirmed by LED blinking Example 1 To assign number 45 press and hold LEARN button until the current controller number is displayed and the green LED is turned on Release LEARN button and press again 4 times Wait for the red LED to turn on and press LEARN button 5 times Wait for the red LED to turn off The number is confirmed by LED blinking Example 2 To assign number 06 press and hold LEARN button until the current controller number is displayed and the green LED is turned on Release LEARN button wait for the red LED to turn on and press LEARN button 6 times Wait for the red LED to turn off The number is confirmed by LED blinking Setting
2. in the top line Otw S01 T M or Zam S01 T M or Stop T M or Roz T M S indicates a single controller If S is underlined press A or V to change the value S to G to select the group of controllers Press A or V to change the value G to S and vice versa Press gt to move the cursor from S or G to the number second digit e g 01 Press A or V to change the number of an individual controller 01 to 64 or a group of controllers 01 to 16 T M in the right end of the top line indicates that the operation can be cancelled press M C or confirmed OK A confirmed operation is initiated immediately Main menu functions Press M C in normal operation mode to display other menu items in the bottom line e Programy T M define timer controlled automatic open close programs e Grupy T M define controller groups e Zegar T M set current date and time e Piloty T M register remote controls e Rozszcz T M program partially open function slight roller shutter opening to let the light into the room Press M C to return to normal operation mode or press OK to select underlined menu item The individual main menu items are described below Defining timer controlled automatic open close programs The central control unit allows to define timer controlled automatic open close programs for individual controllers or group of controllers The time is set in hours from to for specific weekdays Maximum number of
3. via the central control unit The number of a group controlled by ST 02 controller is set on SW1 switch The switch position is shown in ST 02 module diagram ft switch position A up ON U switch position B down OFF Group setting Group setting Group setting Group setting 1 Tt tt tt 5 NNNUNN 9 NNNUNN 13 NNUUNN 2 LINNANI LUNURIN 10 LNINUNN 14 UNVITT 3 TU ATT 7 TVUATT 11 TUT TT 15 TUYUTT 4 Vunntt 8 VUUTTT 12 LUNURIN 16 LUUURN Central control unit operation The central control unit enables OO E e direct keypad opening and or closing individual or group of roller shutters e opening and or closing individual and groups of roller shutters at preset time and day mi e Be A W e remote remote control opening and or closing individual or group of roller shutters with lock function radio receiver lock Connecting central control unit The central control unit is supplied with 230VAC The power supply cables are connected to G4 Connect a two conductor cable from G1 to ST 01 controller Connect G1 2 to GND on ST 01 controller Connect G1 1 of CR 02 central control unit to WEJ on ST 01 controller Display and keypad The central control unit has a two line 16 character each LCD and an 8 button keypad Each button is marked with the following symbols and corresponds to the following functions in different operation modes M C menu enter menu change menu item exit menu OK yes confirm
4. SSN 04 CONTROL SYSTEM FOR ROLLER SHUTTER MOTORS User Manual General SSN 04 control system is safe to use and install if all the guidelines in this manual are met and relevant safety and accident prevention regulations are adhered to All installation and repairs must be carried out by a trained and qualified professional Do not modify the control system in any way All warranty repairs must be performed by the manufacturer Use genuine spare parts and accessories only The operation safety can be guaranteed if used as intended and if the limits are not exceeded Other safety rules Follow relevant safety and accident prevention rules during installation start up and maintenance The following regulations require special attention 1 Fire regulations 2 Accident prevention regulations GENERAL INFORMATION ON HAZARDS AND SAFETY MEASURES The following are the general rules on using INEL controls with other devices which must be adhered to when installing and using the devices A Caution Damage to control system or other equipment may occur if no precautions are taken A Check all screw connections before installing the control system Danger Life and health hazard may occur if no precautions are taken Adhere to the safety and accident prevention rules for specific use e g doors roller shutters Disconnect power cables before replacing the fuses Install all the required safety and protective devices when installing the co
5. ST 01 controller number on PIL 99 remote control and CR 02 central control unit Press LEARN button on ST 01A controller The current controller number is displayed and the controller switches to LEARN mode for approx 10 seconds If another number is selected on the remote control or central control unit the controller in learn mode will store the selected number The number is confirmed by LED blinking If there is no signal within 10 seconds the controller exits the learn mode indicating no change in number with LED blinking If no remote control is available CR 02 central control unit help of another user may be required Example 1 To assign number 19 press and hold LEARN button until the current controller number is displayed and the red LED is turned on Select 19 on the remote control central control unit and press up or down The code is accepted and the number is displayed green LED flashes once and red LED flashes nine times Example 2 To assign number 04 press and hold LEARN button until the current controller number is displayed and the red LED is turned on Select 04 on the remote control central control unit and press up or down The code is accepted and the number is displayed red LED flashes four times Setting group number on ST 02 controller A single ST 02 controller can control a group of ST 01 controllers The group is assigned a number from 1 to 16 The controller number within the group are selected
6. close the roller shutter The roller shutter moves until it reaches its fully open or closed position Press any key during roller shutter movement to stop any time Comfort function ST 02 group controller controls individual ST 01 controllers with a single manual switch A group of roller shutters elevations levels or rooms is defined via the central control unit and can be operated with a single switch NOTE In its previous version the central control unit was not required to configure the ST 02 group controller whereas in its current version CR 02 central control unit is required CR 02 central control unit allows local keypad or remote remote control operation of individual or predefined groups of roller shutters The central control unit allows automatic opening and closing of individual or groups of roller shutters at pre set day and time SYMBOLS roller shutter motor controller ST 01 group controller ST 02 remote central control unit with timer CR 02 ST 01 Controller Cables connected to ST 01 can be classified into three categories 1 Power supply cable supply voltage 230 VAC cable 1 connector G1 1 supply voltage 230 VAC cable 2 connector G1 2 2 Motor supply cables cable up connector G2 5 cable common connector G2 4 cable down connector G2 3 2 Signal cables connection between the controller and central control unit control cable connector GN02 WEJ INPUT
7. etailed ST 01 and ST 02 controller wiring diagram The diagram shows a method of connecting individual devices ST 01 and ST 02 controllers are flush mounted in the double depth back boxes and supplied with 230 VAC Each back box requires mains connection ST 01 controller back box requires motor supply cable connection Connect two conductor cables between all back boxes ST 01 and ST 02 controller and from any back box to the central control unit installation location The wiring will allow system installation Residual Overcurrent noy ST 01 controller PEN current device circuit breaker Dik 30 mA conductor connected to the motor SSN 04 SYSTEM CONFIGURATION A unique number must be assigned to each individual roller shutter to enable remote control Control system configuration requires to assign each individual ST 01 controller a unique number The numbers correspond to remote control commands A roller shutter connected to ST 01 controller no 3 will respond to any commands issued by pressing button 3 The second stage requires to define a motor group i e determine which motor is assigned to which group and to program ST 02 controller i e assign a group number to the controller SETTING ST 01 CONTROLLER NUMBER The number can be set manually via PIL 99GS remote control or CR 02 central control unit Setting ST 01 controller number manually Press and hold LEARN button The controller will switch to manual setting mode
8. hash remove controllers enable or disable programs a square add controllers enable or disable radio lt left change on screen cursor position gt right change on screen cursor position A up change number or value direct control open close partially open y down change number or value direct control open close partially open 4 Central control unit operation modes The following central control unit operation modes are available press M C to select normal operation mode set open close parameters of individual or group of roller shutters at preset time define group of roller shutters set which motors are assigned to each group set current time date and weekday clock and calendar register remote controls to control individual or group of roller shutters Partially open roller shutters at preset time Normal operation mode stand by The following information is displayed in normal operation mode Central control unit options 1 urrent time PR 12 02 33 Wto 26 11 2002 Current weekday i t Current date Current date and weekday are displayed in the bottom line Current time and letters indicating the central control unit operation mode are displayed in the top line The letter indicates if the corresponding option is enabled or disabled Option R enabled disabled with W indicates that the central control unit will respond to remote control commands If this option is disabled the cen
9. he humidity tends to accumulate inside which may result in damage to electronic components Protect system components from high temperatures High temperature reduces the service life of electronic components and may cause deformation and melting of plastic components e Do not drop or throw the device and avoid mechanical damage Careless handling may result in damage to electronic components Protect system components from third party interference workers unauthorised electronics engineers Do not misuse or excessively use the device Do not repair or modify The device can only be repaired by the company which installed the device and issued the warranty Do not use any corrosive substances solvents or strong detergents to clean the device Wipe with a soft cloth and mild detergent In case of any failures or defects notify the company responsible for control system installation immediately The company will provide help in troubleshooting and repairs Failure to observe the quidelines will void the warranty The control system is intended for operation of roller shutter in any configuration The system can be used in many different configurations depending on individual user requirements and conditions The following rule applies to any configuration each motor requires a single ST 01 controller A single ST 01 controller opens and closes a single roller shutter Press ff to open and to
10. nge or confirm left digit Press up down to change value Press right button gt to change or confirm right digit Press up down to change value P If no number is changed up down and stop buttons will issue open close or stop command to individual oO 1 controller or group of controllers e Press OK to switch between individual controller and group of controllers the display shows G to indicate group Press OK again to exit the group Selecting controller or group number in simple mode P e Press left or right button 4 to increase or reduce the number of selected controller group from 01 to to 17 maximum number set e Press up down or stop to issue open close or stop command to the individual controller e Select the maximum number in full mode and switch back to simple mode P G Adding names to individual motors or groups of motors p 5 Each channel can be assigned a name including up to 16 characters capital letters or digits in two lines 8 characters each Press OK and simultaneously to enter edit mode The cursor indicates position that can be 0 1 4 changed with up or down Press 4 gt to change cursor position Press STOP to delete character Press OK to save changes or press to cancel P 6 CAUTION 0 stor After the batteries are replaced all simple mode settings are lost and must be set again whereas the controller group names are stored EDYCJA 0i
11. ntrol system For INEL devices with continuous control voltage supply besides fuse protection use a switch providing safe voltage break e g fuse switch and easy disconnection Periodically check all cables and conductors for insulation damage and breaks Disconnect power supply before replacing damaged cables Check available and permissible voltage before connecting the device WARNING PERSONNEL SAFETY do not allow children to play with the devices keep the devices out of reach of children do not allow anyone near the device until the open close procedure is completed train and instruct users on operation and hazards specific to the device The person is deemed authorised if the employer administrator or owner gave them permission to operate the roller shutter and provided all instructions regarding its use Control system operation and maintenance Please adhere to the following rules to ensure that all the requirements for SNN 04 control system components are met and ensure long term failure free operation Protect system components from humidity Precipitation high humidity and liquids containing mineral compounds may cause corrosion in electronic components Do not use and store the devices in dirty and dusty places plaster gypsum plaster etc It may result in damage to movable system components Do not use the devices at low temperatures no heating The devices tend to heat up during operation and t
12. programs available 32 01 to 32 Select Programy to display program 01 definition e g Program number al f ee indicator Prog 01A17 10 lt Time Weekday gt Sr Pi G01 Otw lt Operation Controller or group Controller or group number Press A or V will change the displayed program definition of underlined program number 01 to 32 The cursor indicates active A or inactive N program If the program is inactive N other information time date and weekday are not displayed Press lt or gt to change the cursor position to select a field and press A or Y to change value Move cursor and press A or Y to change value A to N and vice versa If the program is active A other values can be changed Select hour and press A or V to change value 00 to 23 Select minute and press A or Y to change value 00 to 55 every 5 minutes Other values can be changed weekday individual controller or a group of controllers number and selected operation open close Defining controller groups A group of controllers operated with a remote control central control unit keypad or timer controlled automatic open close program can be defined in the central control unit The group may include any number of controllers 0 to 64 Maximum number of groups 16 01 to 16 Select Grupy to display program 01 definition e g rt Group number Grupa 01 01 03 06 12 13 gt Controller number es ie Next
13. s lt or gt to change the remote control code or press A or Y to move the cursor emote control code PARTIALLY OPEN FUNCTION The central control unit allow to define the partially open function for individual roller shutters Select Rozszez from the main menu The partially open function can be set for all controllers 1 to 64 The time can be set from 0 5 to 8 seconds every 0 5 second The display shows numbers 1 to 16 corresponding to 1 to 0 5 s 2 to 1s etc Press lt or gt to change controller number or move the cursor Press up A or down to select V PIL 99 GS REMOTE CONTROL CAUTION The remote control is in stand by mode to save the battery life Press f lt P to activate the remote control The last selected number is displayed Operation mode and changing operation mode The remote control can operate in two modes Full mode including all controllers 01 to 64 and groups 01 to 16 Simple mode with limited access Press 4 and gt simultaneously to change the mode The selected mode is indicated with a letter P full mode or S simple mode and four digits where the first two digits are a maximum controller number and the other two a maximum group number 5 10 10 Selecting controller or group number in full mode O1 Individual controller number 01 to 64 and group number 01 to 16 can be selected in full mode Procedure Press left button 4 to cha
14. symbol Press A or Vto change the displayed group definition 01 to 16 The bottom line shows the numbers of controllers in the group group items The first item is underlined Up to 5 items are shown due to the screen size If the group contains more than 5 items the first five items are displayed and the next symbol is shown on the right side gt Press gt to move the cursor underline right After reaching the last item and if other items are available next symbol shown press gt to show the next item and hide the first item on the list A previous symbol is shown on the left side lt The cursor can be moved left press lt The screen shows up to 5 items The screen moves right or left if there are any items available on the left or the right side of the screen indicated by lt and or gt on the left or the right side respectively until the end of the line is reached The bottom line shows Pusta if the group does not contain any items Press W asterisk to add group item Dodaj xx is displayed in the bottom line where xx is the item controller number which will be added to the group Press OK yes confirm to confirm The number depends on cursor position and items added so far Only numbers that are not already assigned to the group are available Press A or V to change the number Press M C to cancel Press hash to remove group item Usun xx is displayed in the bottom line where xx is the i
15. tem controller number which will be removed from the group Press OK yes confirm to confirm Press A or V to change the number The number depends on cursor position Only numbers that are already assigned to the group are available Press M C to cancel Setting date and time The internal clock stores its setting even after disconnecting the central control unit power supply Current time date and weekday must be set for automatic timer controlled open close programs to operate properly Select Zegar from the main menu A request to set time is displayed e g E Time hours minutes Ustaw 12 02 Wto 26 11 2002 Weekday E e day month year Press A up or Y down to change hour minute day of the week day of the month month or year The cursor underline initially under the hour setting indicates the value being changed Set date and time and press OK to confirm and return to normal operation mode Press M C to return to normal operation mode without storing any modifications Registering the remote controls Up to four remote controls 1 to 4 can be registered in the system Each remote control has a two digit code on the inner side of the battery cover The code includes numbers 0 to 9 and letters A to F Enter the code to register the remote control No remote control is assigned 00 code and if entered no remote control is registered Select Piloty to display the remote control codes Piloty 00 00 01 02 L_ Pres
16. tral control unit will not respond to remote control commands to protect the system against unauthorised remote access Option P enabled disabled with indicates that individual or group of motors open close programs at preset time and date are active Controlling motors Open close stop and partially open functions for individual or group of motors can be initiated with AorV on the central control unit or the remote control command at preset time The control command may apply to an individual motor controller or a group of motors The group may include any number of motors 0 to 64 with any number assigned to the group A delay of approx 0 5 second between the open close commands by the central control unit is set and thus the operation for a large group can take approx 60 seconds The following information on the action and the motor concerned is displayed instead of the option code when the command is send to the motor Information Otw xx or Zam xx or Stop xx or Roz xx where xx is a motor number 01 to 64 Controlling motors directly using the central control unit keypad Press A or V in the normal operation mode Otw T M or Zam T M and Stop T M or Roz T M is displayed respectively Press A or V to change the operation mode Press M C to cancel and return to normal operation mode Press OK yes confirm to select individual or group of controllers and determine controller or group number The following message is displayed
17. weight connector GN02 GND EARTH ST 02 GROUP CONTROLLER ST 02 connectors can be classified into three categories 1 Supply connector supply voltage 230 VAC cable 1 connector G1 L PHASE supply voltage 230 VAC cable 2 connector G1 N NEUTRAL 0 3154 2307 G1 INEL ST 02 2 2 Signal connector connection between the controller and central control unit control cable connector GN02 WYJ OUTPUT weight connector GN02 GND EARTH o m ONO 3 Manual switch connector X2 for connecting the central alarm control panel voltage free contact Recommended wiring guidelines 1 The electrical system can be designed and installed by an authorised person only 2 Adhere to the relevant legal requirements 3 230 V connector cross section 1 5 mm 4 Control bus connector cross section 0 5 mm Note All double depth 60 mm back boxes for ST 01 and ST 02 controller installation require stranded conductors with the following cross sections CENTRAL CONTROL UNIT WITH TIMER CR 02 The central control unit is connected to the mains and features 230V AC power supply connector G4 and control bus connector G1 signal cable to connector G1 1 earth to connector G1 2 WIRING DIAGRAM Motor 1 Motor 2 Motor 3 Motor 4 Three cables between each ST 01 and corresponding motor motor power supply 230 VAC to each device controller power supply D