Home
Ovation-Manual-122608 b-edit 02 pg 0 Cover
Contents
1. external audio Hexagonal shaped wrench X Spare fuse 2 pcs 9 p Level adjust tool Wrench bolt 8pcs User s Guide User s Guide Specifications amp Main Features MEM Model e 12590 OVATION Applicable Frequency e 0 1 100 000Hz Operating Frequency e 3 60Hz Max Allowable Load e Max 250 lbs Power Source e 110V 220V 50Hz 60Hz Power Consumption 300W 500W Sonic Wave Generator e 245mm X 1 Operating Conditions e Temp 0 40 C 32 104 F Humidity 0 8296 Size amp Weight e Body L 510 x W 395 x H 1318mm 30kg Plate L670 W 656 x H 243mm 80kg oet L670x W 905 x H 1395mm 110kg Finish Powder coat Black Acrylic Feel Great Great Control Panel he specifications may be changed if necessary at the sole discretion of the manufacturer and without prior notice Turbos nic User s Guide Assembly and Disassembly Instructions Assembly 1 Place the body close to the plate and connect the internal connection cables 2 lines INN Use caution not to bind or pinch cables wires in any way 2 Align the guide pin of the plate with the body then insert 4 each M8x20cm wrench bolts at side of body 3 Fasten the 4 bolts under the plate tight enough not to sway by using the enclosed hexagon shaped wrench With the level adjust tool level the product with the floor by adjusting the leveling screw under the plate For more precision adj
2. 00 0v 0 0000 o0 G0 0000000000000 1 After removing the power cord RSS press and turn the fuse covering AR _ holder to counterclockwise by using a straight slot screwdriver 1995 S Y tm 14 y e CM 9 V il 2 As shown in the photo extract the fuse holder remove the fuse in the left slot of the holder EMT OX HOY HOY Solr oe 09000000 OY 0 VOUS 0 NEW lt J OF BUT il Ne SS v D A gt g a e 3 Replace with spare fuses which are supplied in the package contents 4 Replace the right side fuse if the machine is still not working after changing the left side fuse When all of the supplied spare fuses are used please purchase specified fuses for further replacement Fuse 250V 12A User s Guide TurboS nic Warranty OVATION Your TurboSonic is warranted to be free from manufacture or workmanship defects for a period of 3 years in accordance with a conditional warranty provided separately by TurboSonic USA The TurboSonic Ovation is for home use only Any commercial or professional use of this product will void warranty See warranty conditions for specific terms Disclaimer Great Turbosonic USA Feel Disclaimer of warranties and Limitation of Liability This User s Manual is provided by Turbosonic USA on an as it ba
3. AE4 Indicates that customer stepped down from the plate before stopping the machine Please press STOP button and it will be returned to normal Check if the place where the product is located is tilted Check if the product is not level with the floor Relocate the product to a level and solid floor Level the product by adjusting the leveling screw under the plate Check if too many plugs are connected to the power outlet where the product is connected Use an exclusive power outlet for the product Check if the INTENSITY is set to 0 Intensity can be controlled only in MANUAL mode Adjust the intensity with the INTENSITY knob Look Great Feel Great User s Guide Manual Mode OVATION Stimulated region by Frequency Hz 3Hz Whole body walk 4Hz Arm Shoulder 5Hz Chest Shoulder 6Hz Shoulder Back 7Hz Back Abdomen Trunk 8Hz Abdomen Hip Thigh 9Hz Hip Thigh Abdomen Thigh Inner Look Thigh Inner Prostate Man Knee Face Feel Whole body Backbone Face Whole body Backbone Trapezius Thigh Front Calf Thigh Front Calf Abdomen Thigh Inner Front Pelvis Whole Body Stimulation Whole Body Stimulation Whole Body Stimulation Pelvis Side Sartorius Underbelly Women Y Pelvis Side Sartorius Underbelly Women Calf Thigh Back Calf Thigh Back moore deme rir Quick Replacement of Fuse 09 OD Ur od 00
4. TurboS nic Therapy System The Science of Sound D a 9 5 E THE HOME MODEL TurboS nic www turbosonicusa com Contra Indications for use AY Consult a physician before using this equipment for the first time Stop the machine immediately if experience chest pain faintness difficulty breathing or severe discomfort Warning Serious cardiovascular condition Pacemaker or other electrical implant Pregnancy Acute thrombosis Hip knee or other joint replacements Epilepsy Severe migraine Tumor Recently placed IUD metal pins or plate If any of the conditions listed above apply to you consult your physician or competent health care practitioner who is familiar with whole body vibration therapy before using the Turbosonic User s Guide Please read through this User s Guide prior to use After you have finished reading this manual please keep it in a safe place oave the shipping box and all packaging Warranty void if returns are not made with original packing materials 1 Contra Indications of use i 2 Welcome 2 3 Package Contents 3 4 Specifications amp Main features 4 5 Assembly amp Disassembly Instruction 5 6 Safety Guides 6 Safety guide for product handling amp Symbol Chart Safety guide for product handling amp installation Safety guide for operation Safety guide for maintenance amp s
5. can be selected from 0 99 Press INTENSITY knob when you need to pause START Start the operation manually in selected mode In manual mode the default exercise time is preset as 10 minutes and increased by 1 minute per press up to max 20 minutes Restart the operation when the operation is in pause STOP Stops the operation manually Press and hold the stop button more than 2 seconds to turn the machine off and change to the standby mode Select left side mode on the display Select right side mode on the display User s Guide Operating Guide OVATION 1 Plug the power cord at the rear of the body into the power source 2 Step on the plate and place feet shoulder width apart 3 Press and hold STOP button more than 2 seconds machine will begin operating mode Manual Mode 4 Select MAN Manual mode by using mode selection button Initial mode is set at MAN 5 Select required Hz by using the FREQUENCY knob for exercise level appropriate for user ECT 6 Press START button Great 7 Press TIMER button repeatedly to set the time Exercise time is preset for 10 minutes and exercise time can be increased per press by 1 minute up to max 20 minutes 8 By using the INTENSITY knob set the intensity 0 99 for exercise level appropriate for user Great 9 To stop while in operation simply press INTENSITY knob to Pause the machine Press START bu
6. ear product NV Not Allowed Please do not spray water directly do not use benzene NV thinner or bleach for cleaing the product Not Allowed Look Great Please remove the power plug from NV the power outlet before cleaning Not Allowed Feel Great To clean the control panel please wipe up with a dry cloth avoiding water penetration o under the control panel Observation To clean the outside of the product E please use appropriate cleanser which is suitable with the material of the product Observation Please clean and dry the product before long term storage 1 Y Observation User s Guide Control Panel OVATION um INTENSITY be Wellness nua in planin eiu EN 1 2 1 rf 6 M T 3 10 e 22 po FREQUENCY ec Display O Hz Displays frequency of vibration from 3 to 60 Hz 2 Displays intensity of vibration from 0 to 99 Displays the rest time from set time 3 TIME Max 20 minutes can be set per session 4 Intensity Volume ee 7777 Operating Mode is displayed L M H L M H L User s Guide Control Panel Button amp Dials FREQUENCY Hz The frequency Hz can be selected at an interval of 0 1 Hz by using the Frequency knob In MANUAL MAN mode speed of vibration can be selected by number of frequency from 3 to 60 INTENSITY PAUSE In MANUAL MAN mode Intensity of vibration
7. neously by connecting external sound sources such as MP3 player or PC into the audio input terminal of the product IN OUT TONE AGC o 1 IN External sound sources can be input into this terminal 2 OUT Sound sources such as can be output through this terminal by using headset or earphone 3 TONE Control a quality of a tone between high and low tone 4 AGC Automatic Gain Control regularize the level of sound User s Guide Troubleshooting List Before Service O N T ION Power does not come on Error Message while in operation Excessive shaking and noise in the body while operating The product stops suddenly during operation No vibration in the plate while the control panel works normally Check Point Solution Check Point Solution Check Point Solution Check Point Solution Check Point Solution Check Point Solution Check if the power cord is not connected to power source properly Check if the power switch is Off Check if the fuse has blown Connect the power cord firmly Turn the power switch Replace the fuse refer to page 16 E1 Short Circuit E3 Over Weight E2 Over Heat AE4 No Load E1 Contact after sales service immediately E2 Please allow the machine to cool down for about 2 minutes AE3 The weight of user is over the MAXIMUM allowable weight which is 250 Ibs
8. ng the maximum power a consumption of the product V7 Observation Proper carrier shall be used to move the product or inappropriate move may cause damage to the product Observation To move the product please lift and move the product holding the grips under the plate D amp Q inthe photo below Never lift unit by the plate as it will damage the product 1 User s Guide Safety Guide OVATION Safety guide for operation When preparing for exercise an improper stance may Cause injury Please press the Start button only after standing Observation firmly upright on the plate with feet shoudler width apart 9 Stepping down from the plate while in operation could result a in injury Please make sure the product comes to Observation complete stop before stepping off the plate G 9 Jumping on the plate of product while in operation e may cause bodily injury or damage to the product Sarl Observation Great b When the aged elderly or children use the product e they need to be supervised by a guardian Observation In any case please do not disassemble repair O or modify the product as this could result in damage N or malfunction of the product Disassembly Any objects piled up on the plate may cause damage to the product Not Allowed 1 User s Guide Safety Guide Safety guide for maintenance amp storage Please do not place any flammable material n
9. rea Food amp Drug Administration U S NRTL Certificate Certificate ce CE MDD TurboS nic www turbosonicusa com
10. sis Turbosonic USA makes no representations or warranties of any kind express or implied as to the information or content included in this Manual The User Manual and its content is provided for general information only and should not be relied upon or used as the basis for making significant decisions without consulting primary or more accurate more complete or more qualified sources of information and or health professionals Any reliance upon the Manual and its content shall be at your own risk Neither we nor any third party involved in creating or producing the manual is responsible for its contents or for any consequence relating directly or indirectly to any action or inaction taken based on the Manual and its content Subject to change All terms herein are subject to change without prior notice TurboSonic USA Toll Free 877 684 7245 P O Box 1277 Fax 541 387 4503 Hood River Or 97031 Email info turbosonicusa com User s Guide www turbosonicusa com Excellence in Vertical Vibration TurboS nic Domestic Patent VIBRATORY APPARATUS OF EXERCISE MAGNETIC CIRCUIT EQUIPPED WITH DUAL MAGNET AND ITS APPLIED SPEAKER amp VIBRATOE USED IT WITHIN Overseas Patent US patent No US 7 141 029 B2 VIBRATORY APPARATUS OF EXERCISE U S Food amp Drug Administration HH07793 6001A KETI Safety Certificate of Electric Appliance 60335 Certificate ISO 9001 2000 ISO 13485 2003 Ko
11. torage 7 Control Panel 10 8 Operating Guide 12 9 Troubleshooting List Before Service 14 10 Manual Mode 15 11 Quick Replacement of fuse 16 12 Warranty ____ 47 Welcome OVATION Thank you for purchasing your TurboSonic VibrationTherapy Trainer and welcome to a growing community of TurboSonic enthusiasts Welcome also to a new dimension in health and long term well being never before attainable Your Turbo Sonic is the most technologically advanced whole body vibration device available in the world today Its ability to generate precise low frequency vibrations at varying intensities can enhance the health and well being of you your family and your friends for many years to come Here at TurboSonic USA we dedicate ourselves to providing the latest innovative non toxic non invasive life restoring Great health solutions available _ Please take the time to read this User s Guide thoroughly in Great order to become familiar with the set up operation and maintenance of your new TurboSonic Contact us if you have any questions or concerns We d love to hear any stories you d like to share about how your TurboSonic may have enhanced your health and the quality of your life To your radiant Health Happiness and long term Well Being Jim Cole CEO TurboSonic USA User s Guide Package Contents Separate packing for the body and plate is available Main System Audio connection cable Input
12. tton to operate again 10 To stop simply press STOP button It slows down gradually for 5 seconds Please make sure the operation stops completely before stepping down from the plate 11 Turn the machine to standby mode by pressing and holding STOP button more than 2 seconds 12 When the machine is not used for 30 minutes it will switch to Standby mode automatically for saving power consumption User s Guide Operating Guide Program Mode 4 Select the desired program by using mode selection button Please refer to page 17 for program mode details Select the appropriate intensity L Low M Medium H High 5 Press START button 6 Exercise time is preset for 10 minutes 7 To stop a moment while in operation simply press INTENSITY knob to turn the machine to pause Press START button to Look Operate again 8 To stop using simply press STOP button It slows down gradually for 5 seconds Please make sure the operation stops completely Feel before stepping down from the plate v Great 9 Turn the machine to standby mode by pressing and holding STOP button more than 2 seconds 10 When the machine is not used for 30 minutes It s turned to Standby mode automatically for saving power consumption Audio System This is the world s first system exclusively developed by Turbosonic which enables the user to feel not only vibration but also the sound simulta
13. ust by hand 4 Connect the power cable to the power terminal at the rear of the body and turn the power switch ON by pressing the STOP button and holding more than 2 seconds 5 To operate the machine press START oo vu we and dial the INTENSITY knob to the desired level Wax 0 4 B 4 T B bw mt L E w X w P Xi W M L W M Disassembly 1 Power cable must be removed first prior to starting disassembly 2 Proceed with disassembly by following the assembly sequence in reverse 1 3 to 1 Safety Guide MEM Safety guide for product handling Users shall follow instructions below for warning and attention to insure safe and proper operation of the product Caution instructions are distinguished as follows Warning Attention Meaning of Symbols D Q dE Observation No Ground Disassembly NV Not Allowed Remove Power Plug User s Guide Safety Guide Safety guide for product handling amp installation Please do not install the product in wet or damp area Gy Not Allowed For installation please avoid areas close to outdoors where it may come in contact with water NO Not Allowed The product shall be installed away from the wall with a space of no less than 8 inches L Observation The product shall be installed on a solid and level floor e Observation Be sure the power outlet is a dedicated circuit and is capable of supporti