CM P1 11643-4 EN Microlog Accessories Catalog
Contents
1. 38 Power Trigger splitter straight cable CMAC 5032 38 Audio headphone straight cable CMAC 5078 39 USB Ato B straight cable CMAC 5082 39 Temperature gun interface straight cable CMAC 5087 40 Signal input straight cable CMAC 5088 40 USB communication power splitter straight cable CMAC 5095 41 AC DC signal coiled cable CMAC 5116 41 Trigger coiled cable CMAC 5117 42 Serial communication cable CMAC 5201 42 Strobe light input straight cable CMAC 5404 43 Strobe light output straight cable CMAC 5406 43 Signal input straight cable microphone cable CMAC 5093 44 Important SKF Microlog connectors use a locking mechanism for secure connections To disconnect Fischer cables from the SKF Microlog connectors pull on the lower portion of the connector as illustrated below N N i d Correct way to disconnect cables M 28 Wrong way to disconnect cables aKF Cable recommendations The following tables shows which cables are recommended for the accelerometers and hardware found in this catalog C
2. 93 Belt tension gauge CMAC 5139 CMAC 5140 94 76 aKF CMAC 5010 Shoulder strap This shoulder strap fastens directly to the rubber boot CMAC 5015 or to the instru mentitself The strap features a metal plate to hold the sensor magnet CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Ordering information e CMAC 5010 Shoulder strap aKF CMAC 5073 Shoulder strap The CMAC 5073 shoulder strap is adjustable and features a removable steel plate that has been designed to hold a few transducers if fitted with a magnetic mount This plate is attached via two heavy duty press studs and can be removed if not required The strap also has a safety breakaway The breakaway strength is adjustable and may be set to break easily or not so easily to user prefer ence Ordering information e CMAC 5073 Shoulder strap CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 77 CMAC 5113 CMAC 5020 CMXA 45 CMXA 45 Shoulder strap leather Hand strap hazardo us areas CMXA 45 75 Z2 Q CMXA 45 75 Z2 CMXA 48 CMXA 48 The CMAC 5113 shoulder strap is part of the TREST The hand strap is provided in all kits and is TERIO SKF Microlog ATEX certification it may be designed for easier and safer operations of affixed to the SKF Microlog wh
3. 29 Accelerometer cables Triaxial accelerometer coiled cable CMAC 5009 30 High frequency accelerometer straight cable CMAC 5061 30 High frequency accelerometer straight cable CMAC 5062 31 Splitter four channel straight cable CMAC 5079 31 ATEX certified accelerometer coiled cable CMAC5115 32 Accelerometer coiled cable 2 m 6 56 ft CMAC 5209 32 Accelerometer coiled cable with safety breakaway CMAC 5209 065 33 Accelerometer coiled cable 3 m 10 ft CMAC 5209 10 33 Tachometer cables BNC tachometer straight cable CMAC 5211 34 Laser tachometer kit straight cable 24 cm 9 5 in CMAC 5213 34 Laser tachometer kit straight cable 2 m 6 56 ft CMAC 5214 35 Extension cables CH1 signal input straight extension cable 5 m 16 4 ft CMAC 5036 35 CH1 signal input straight extension cable 10 m 32 8 ft CMAC 5037 36 Tachometer straight extension cable 5 m 16 4 ft CMAC 5043 36 Tachometer straight extension cable 10 m 32 8 ft CMAC 5044 37 aKF 21 Miscellaneous cables Cable converter two pin MIL to BNC CMAC 3715 37 Signal input straight cable CMAC 5023
4. 56 AC DC current clamp CMAC 5208 57 SKF Microlog Analyzer field balancing accessory kit CMCP 850 01 CMCP 850 02 CMCP 850 03 59 Optical phase reference kit CMSS 6155KK U CE 60 Optical phase reference magnetic holder CMSS 6156 63 Strobe light kit CMSS 6165K AK 64 Smart laser sensor tachometer CMSS 6195AK K 67 aKF 45 CMAC 4200 K SL Infrared thermometer The SKF CMAC 4200 K SL infrared thermometer with laser sighting is a rugged easy to use portable non contact thermometer Ideal for a broad range of maintenance tasks the CMAC 4200 K SL may be connected directly to the SKF Microlog series analyz ers for quick accurate recording of surface tempera tures It is one of a variety of accessories offered by SKF to work with the SKF Microlog in enhancing the overall effectiveness of a predictive maintenance program The CMAC 4200 K SL measures the amount of infrared energy emitted by an object and converts it to a display of the object s sur face temperature The handheld infrared thermometer takes non contact temperature measurement technology to a new level Features e Designed for physically challenging environments e Easyto use e Adjustable emissivity with on board table e Fastresponse time e Ac
5. 84 Docking station CMXA 48 CMXA 80 CMAC 5068 84 Screen protector CMXA 48 CMXA 80 CMAC 5074 85 Screen protector CMXA 45 CMXA 75 CMAC 6139 85 SD memory card 4 GB CMAC 5077 86 Stylus IS CMAC 5251 86 aKF 75 Audio headset hard hat compatible CMAC 5403 87 Labels for measurement locations CMAC 5222 87 Idler sound monitor accessories Audio headphones cable CMAC 5078 88 Microphone with preamplifier CMAC 5091 88 Signal input straight cable microphone cable CMAC 5093 89 Parabolic reflector CMAC 5141 89 Adapter plate CMAC 51442 90 Wind jammer CMAC 5143 90 SKF spindle assessment accessories Pull force gauge CMAC 5121 CMAC 5122 91 Pull force gauge taper rings CMAC 5123 through CMAC 5125 92 Pull force gauge adapters CMAC 5126 through CMAC 5136 92 Run out gauge CMAC 5137 93 Depth micrometer CMAC 5138
6. CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Microphone with preamplifier Ordering information e CMAC 5084 Microphone with integral preamplifier kit includes a microphone with preamplifier CMAC 5023 cable and a calibration certificate ok CMAC 5208 AC DC current clamp The CMAC 5208 AC DC current clamp is a battery powered clamp on current probe that is used on primary circuits with the SKF Microlog Analyzer to measure AC or DC currents up to 600 A peak AC 600A DC Features e Solid state hall effect transducer AC 1 Hz to 5 kHz and DC 0 to 1 Hz measurement e Ranges 60 and 600A e Degaussing adjustment for zero noise offset The AC DC current clamp allows a user to easily and safely incorpo rate current monitoring within SKF Microlog routes The jaws clamp around a conductor allowing current measurements without break ing the circuit A Hall Sensor mounted in a gap in the core senses the magnetic field produced by the current being measured An amplifier circuit generates an output signal of 1 mV A 600 A range or 10 mV A 60 A range Demagnetizing degaussing is accomplished by means of a push button Lightweight and easy to carry the AC DC current clamp may be used throughout the plant or in control room environments This current clamp is equipped with a connector that fits the CH1 or CH2 input connectors Specifications Electr
7. CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Light output Average 11 W at 3 000 flashes per minute 13 W above 3 450 flashes per minute nstantaneous per flash 230 mJoule typical to 3 450 flashes per minute e Flash duration 10 to 25 microseconds auto adjust with flash rate Flash tube lamp life 100 million flashes Run time Two hours typical at 1 800 flashes per minute and over one hour at 6 000 flashes per minute with fully charged batteries Charge time Four to five hours typical with PSC pbxU Weight 0 8505 kg 1 875 lbs including batteries This product is designed to be safe for indoor use under the following conditions per IEC61010 1 e Operating temperature O to 40 C 30 to 105 F e Humidity Maximum relative humidity 8075 for temperatures up to 30 C 90 F decreasing linearly to 50 relative humidity at 40 C 105 F Flash range 30 to 50 000 flashes per minute Tachometer measurements 5 to 250 000 r min Tracking filter Selectable wide and narrow bandwidths the filter may not lock below 100 flashes per minute External input 10 or 100 mVg accelerometer powered by an analyzer or by the strobe menu selectable Safety thermal feature will set unit into TACH Mode stops flashing in the event of internal overheating Note The CMSS 6165 strobe light is not approved for use in hazardous locations aKF Kit cont
8. 5 2 0 to 15 000 Hz 3 dB 0 5 to 25 000 Hz Amplitude non linearity 1 Resonance frequency 60 kHz Transverse sensitivity 5 of axial Temperature response 50 C 60 F 5 120 C 250 F 5 Electrical e Power requirements Voltage source 18 to 30V DC Constant current diode 2 to 10 mA e Electrical noise Broadband 2 5 Hz to 25 kHz 200 ug Spectral 10 Hz 20 ug Hz 100 Hz 3 ug Hz 1000 Hz 2 ug Hz 10 000 Hz 2 ug Hz e Output impedance lt 100 0 e Bias output voltage 10 V DC e Grounding Case isolated internally shielded 20 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Environmental e Temperature range 50 to 120 C 60 to 250 F e Vibration limit 500 g peak e Shock limit 5 000 g peak e Base strain sensitivity 0 005 g u strain e Electromagnetic sensitivity equivalent g 100 ug gauss Physical e Dimensions See drawing e Weight 13 g 0 5 oz e Mounting 10 x 32 tapped hole e Case material 316L stainless steel e Connections Shell Common Pin A Power Signal Output connector 10 x 32 coaxial Mating connector R1 e Recommended cable CMAC 5061 e Recommended magnetic base CMSS B13 aKF Optional accessories CMSS B13 magnetic mounting base CMSS B13 magnetic mounting base specifications e Description Rare earth two pole magnet
9. CMXA 75 CMXA 80 352A60 high frequency constant current accelerometer CMAC 5062 high frequency accelerometer cable Adhesive mounting base aKF Kit contents e 352A60 High frequency constant current accelerometer e CMAC 5062 High frequency accelerometer cable Fischer type 103 six pin to a 5 44 Microdot connector e Adhesive mounting base Note Loctite 454 insensitive adhesive gel is the recommended adhesive This item is not included in the kit aKF Dimensions 2 3 mm eu in A 5 44 coaxial connector 20 6 mm 0 81 in 10 32 mounting hole 2 2 Sn 0 13 in 1 Stud removed for sensor with adhesive mount option 2 M6 x 0 75 thread for Metric option 10 7 mm OER on Ordering information e CMSS 2114 K High frequency accelerometer kit which includes a high frequency constant current accelerometer cable and adhesive mounting base 15 CMSS 2200 CMSS 2200 M8 General purpose low profile side exit industrial accelerometer The CMSS 2200 and CMSS 2200 M8 industrial accelerometers with their side exit and two pin connector offer a low profile for machinery with limited clearance The sensor mounts in any orientation Features Rugged economical and all around general purpose sensor 100 mV g sensitivity to optimize use in multiple applications Exceptional bias voltage BV stability at elevated temperatures Designed for exceptional
10. aKF CMAC 5095 USB communication power dia splitter straight cable ET CMXA 48 The CMAC 5095 four core shielded USB CMXA 48 80 Z2 cable has a standard USB Type A plug The cable is used for USB communications and CMXA 51 IS power without the docking station The USB Type A plug is used to connect to oe e the PC while the in line DC jack socket con CMXA 75 nects to the CMAC 5090 universal power CMXA 80 supply and the Fischer plug connects to the SKF Microlog Specifications e Connectors USB Type A and a standard 2 1 mm 0 083 in in line DC jack socket to Fischer SE103A05 7 130 plug e Length 2 m 6 56 ft straight Ordering information e CMAC 5095 USB communication power splitter straight cable aKF CMAC 5116 AC DC signal coiled cable The CMAC 5116 cable is offered as an optional accessory It is not part of the CMXA 51 15 ATEX certification therefore it must be approved by the site s safety officer before use in a hazardous area Specifications e Connectors Fischer four pin to BNC e Length 2 m 6 56 ft coiled Ordering information e CMAC 5116 AC DC signal coiled cable CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 41 CMAC 5117 Trigger coiled cable The CMAC 5117 cable is offered as an optional accessory It is not part of the CMXA 51 IS ATEX certification therefore it must be approved by the site s safety
11. Discharging 10 to 60 C 15 to 140 F Storage 1 year 20 to 20 C 5 to 70 F Physical e Dimensions 110 3 x 19 5 x 72 0 mm 4 34 x 0 77 x 2 83 in e Weight 290 g 10 2 oz Protection Minimum Typical Maximum e Over current A 5 00 8 33 8 89 e Short circuit A 14 82 29 13 43 61 e Over voltage V 8 65 8 70 8 75 e Under voltage V 4 40 4 60 4 76 Approvals e Emissions EN61000 6 4 2001 Severity Level Class A e Immunity EN61000 6 2 2001 Severity Level Class A e CSA Class Division 2 Gas groups A B C and D Canadian and US standards e ATEX EN60079 0 2006 EN60079 11 2007 EXII 3 G Ex icIICT4 Gc T 10 to 50 C 15 to 120 F e ECEx IEC 60079 0 Ed 4 0 IEC 60079 11 Ed 5 Ex icIICT4 Gc T 10 to 50 C 15 to 120 F Transportation UN Directive ST SG AC 10 11 Rev 3 Equivalent Lithium content 3 96 g 0 1397 oz Ordering information e CMAC 5092 Battery 72 aKF CMAC 5090 Universal power supply non IS The CMAC 5090 universal power supply is used for connecting the docking station to the power cord This power adapter delivers power to the SKF Microlog while charging the battery when inside the instrument lt also features a connector to mate with the USB splitter cable CMAC 5095 or the dock ing station CMAC 5068 Since this universal power supply can support 100 to 240 V input it also comes with USA UK AUS and EURO adapter plugs Orderin
12. Foreword Unmatched versatility reliability and functionality have made the SKF Microlog Analyzer series of data collectors the premier choice for portable handheld condition monitoring units Designed to help users establish or upgrade an existing condition monitoring program SKF Microlog Analyzers handle the tasks required to perform predictive maintenance on rotating machinery in countless industries Data capture from a range of sources SKF Microlog Analyzers automatically collect both dynamic vibration and static process measurements from almost any source including handheld and magnetically mounted accelerometers permanently mounted vibration sensors or on line monitoring systems Temperature measurements can be collected with a non contact infrared sensor or with a contact probe State of the art operating technology With robust high speed data processors and optimum data storage capacity SKF Microlog Analyzers are equipped to operate within today s most advanced computerized maintenance management systems Units can be purchased with a range of individual modules and accessories for specific types of analysis required to meet their plants monitoring needs aKF Product compatibility Every product listed in this catalog contains a legend that shows which SKF Microlog models are compatible with that product An example of the legend is shown below For example a product that contains the legend below would be c
13. e CMSS 908 MD Medium duty magnetic bases for accelerometers two CMCP 811 Set of assorted balance weights CMCP 625 Two pin 5015 to BNC adapters two CMSS 6156 Magnetic holder CMCP 665 6PIN 7 6 m 25 ft BNC to Fisher 103 six pin accelerometer cables two CMCP 665 7PIN 7 6 m 25 ft BNC to Fisher 103 seven pin accelerometer cable one e CMSS 1 5 Roll of reflective tape 600 g 21 164 oz digital scale e Custom vise grips with M8 thread Banana to BNC adapters three Hex key set e Jape measure Stainless steel rule 15 2 cm 6 in Protractor 180 15 2 cm 6 in Compass Clipboard with storage Polar plot tablet Application notes Watertight hard carrying case Ordering information e CMCP 850 01 Microlog Analyzer field balancing accessory kit with Optical sensor e CMCP 850 02 Microlog Analyzer field balancing accessory kit with laser sensor e CMCP 850 03 Microlog Analyzer field balancing accessory kit with laser sensor 59 CMSS 6155XK U CE Optical phase reference kit The CMSS 6155XK U CE optical phase reference kit allows you to easily monitor speed and phase angles on any operating machine by triggering off of reflective tape or paint on the shaft surface The optical phase reference system can measure speed and provide a trigger for absolute and relative phase mea surements at distances up to 0 9 m 3 ft The purpose of phase measurement The angular distance between a refe
14. 2 to 20 mA Output impedance x 100 Q e Output bias voltage 8 to 12V DC Discharge time constant 0 5 to 2 0 s Settling time within 104 of bias 5s Spectral noise 1 Hz 3 200 ug Hz 10 Hz 700 ug Hz 100 Hz 180 ug Hz 1 kHz 64 ug Hz aKF Environmental e Overload limit shock 98 100 m s pk 10 000 g pk e Temperature range operating 55 to 120 C 65 to 250 F e Base strain sensitivity lt 0 0005 a u strain Physical e Size hex x height 12 7 x 29 0 mm 0 50 x 1 14 in e Weight 10 5 g 0 38 oz e Sensing element Quartz e Sensing geometry Shear e Housing material Titanium e Sealing Welded hermetic e Electrical connector 10 32 coaxial Jack e Electrical connection position Top e Mounting thread 10 32 female CMAC 5057 Accelerometer 353B16 Dynamic e Sensitivity 104 1 02 mV m s 10 mVg e Measurement range 4 905 m s peak 500 g peak e Frequency range 5 1 to 10 000 Hz 10 0 7 to 20 000 Hz 3 dB 0 35 to 30 000 Hz e Resonant frequency gt 70 kHz e Broadband resolution 1 to 10 000 Hz 0 05 m s RMS 0 005 g RMS e Non linearity x 1 e Transverse sensitivity lt 5 Electrical e Excitation voltage 18 to 30V DC e Constant current excitation 2 to 20 mA e Output impedance 1000 e Output bias voltage 8 to 12 V DC e Discharge time constant 0 5 to 2 0 s e Settling time within 10 of bias 5 s e Spectral noise 1 Hz 3 200 ug
15. 4 25 4 5 4 75 Approvals e Emissions EN61000 6 4 2001 Severity Level Class A e Immunity EN61000 6 2 2001 Severity Level Class A e CSA Class Division 2 Gas groups A B C and D Canadian and US standards when installed in a CMXA 70 or CMXA 75 ATEX EX II 3 G Ex ic IICT4 Gc T 10 to 50 C 15 to 120 F when installed in a CMXA 75 IECEx Ex ic IICT4 Gc T 10 to 50 C 15 to 120 F when installed in a CMXA 75 Transportation UN Directive ST SG AC 10 11 Rev 4 Part 111 sub section 38 3 Equivalent Lithium content 1 47 g 0 0519 oz Ordering information e CMAC 5031 Battery 70 aKF CMAC 5070 Battery CMKA 45 CMXA 45 75 Z2 Par No BP5 CMXA 48 The 7 2 V Lithium lon 6 600 mAh recharge Want CMXA 48 80 72 able battery pack provides customers with TUN pcr OE eight hours of continuous data collection or Dei iM cd CMXA 51 IS 10 hours idle Charging time is six hours The Ed TER TOE battery can be charged in the instrument through the docking station CMAC 5068 CMXA 75 CMXA 80 Specifications Electrical e Nominal voltage 7 4 V e Nominal capacity 6 6 Ah e Operating time Eight hours continuous data collection en hours idling in a process product e Charge time 6 hours in suspend mode Environmental e Temperature range Charging 10 to 45 C 50 to 115 F Discharging 10 to 60 C 15 to 140 F Storage 1 year 20 to 20 C 5 to
16. CMAC 5251 CMAC 5403 CMAC 5404 98 Description Signal input straight cable microphone cable USB communication power splitter straight cable Battery Power supply Carrying pouch leather hazardous areas Shoulder strap leather hazardous areas ATEX certified accelerometer coiled cable AC DC signal coiled cable Trigger coiled cable Carrying case hard shell Pull force gauge 2 5 to 20 0 kN Pull force gauge 10 0 to 75 0 kN Pull force gauge taper ring SK30 Pull force gauge taper ring SK40 Pull force gauge taper ring SK50 Pull force gauge adapter SK30 ISO Pull force gauge adapter SK40 ISO Pull force gauge adapter SK50 ISO Pull force gauge adapter SK30 MAS Pull force gauge adapter SK40 MAS Pull force gauge adapter 32A HSK Pull force gauge adapter 40A HSK Pull force gauge adapter 50A HSK Pull force gauge adapter 63A HSK Pull force gauge adapter 80A HSK Run out gauge Depth micrometer Belt tension gauge 15 to 70 kg 30 to 150 lbs Belt tension gauge 50 to 150 kg 100 to 300 lbs Parabolic reflector Adapter plate Wind jammer Serial communication cable AC DC current clamp Accelerometer coiled cable 2 m 6 56 ft Accelerometer coiled cable with safety breakaway Accelerometer coiled cable 3 m 10 ft BNC tachometer straight cable Laser tachometer kit straight cable 24 cm 9 5 in Laser tachometer kit straight cable 2 m 6 56 ft Labels for measuremen
17. Medium duty magnetic base CMSS 908 MD 26 aKF CMAC 4370 K Triax accelerometer kit SKF s triax accelerometer quickly and auto matically measures horizontal vertical and axial triaxial data with the press of a button Triaxial measurements offer the user addi tional information on the condition of machinery enabling a more complete diag nostic analysis For example measuring in a vertical direction often provides insight into how the shaft is restrained when considering bearing looseness A horizontal orientation is preferred for bearing fault diagnosis and an axial measurement can provide clues as to the severity of shaft misalignment The SKF Microlog can acquire data simultaneously from all three axes The triax accelerometer also enables measurement in any of the three axes where in specialized cases a single point accelerom eter would be unable to measure data due to physical mounting restrictions or a difficult to access mounting surface For those who typically collect triaxial data the sensor dramatically reduces data collection time For users who up until now have col lected only one data point per sensor location triax offers the advan tage of additional information for improved diagnostics The triax accelerometer facilitates the efficient collection of accurate and repeatable machine date for enhanced decision making Specifications for triax accelerometer Dynamic e Sens
18. Working closely with you Our objective is to help our customers improve productivity minimize mainten ance achieve higher energy and resource efficiency and optimize designs for long service life and reliability Innovative solutions Whether the application is linear or rotary or a combination of the two SKF engineers can work with you at each stage of the asset life cycle to improve machine performance by looking at the entire application This approach doesnt just focus on individual components like bearings or seals It looks at the whole application to see how each component interacts with the next Design optimization and verification SKF can work with you to optimize current or new designs with proprietary 3 D model ing software that can also be used as a vir tual test rig to confirm the integrity of the design aKF Design and develop SKF Life Cycle Management ro ad mission A 9 2 YG 0 Perate and monitor Bearings SKF is the world leader in the design development and manufacture of high performance rolling bearings plain bearings bearing units and housings Machinery maintenance Condition monitoring technologies and main tenance services from SKF can help minimize unplanned downtime improve operational efficiency and reduce maintenance costs Sealing solutions SKF offers standard seals and custom engineered sealing solutions to increase uptime improve machine reliabi
19. accessories However it reguires approval by the site s safety officer prior to entering a hazardous area Ordering information e CMAC 5118 Carrying case hard shell aKF CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5075 Fischer and audio connector cover set 3 bd o The CMAC 5075 kit consists of a set of three i j o Fisher connector covers including two type 103 covers and one type 102 cover o o Ordering information e CMAC 5075 Fischer and audio connector cover set 3 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 83 CMAC 5083 SDIO and dock connector cover The CMAC 5083 SDIO and dock connector cover attaches to the bottom of the SKF Microlog with two screws and a tether The cover protects the SD memory card slot and docking station connectors in harsh environ ments Ordering information e CMAC 5083 SDIO and dock connector cover 84 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5068 Docking station The CMAC 5068 docking station is used for docking the SKF Microlog while supplying it with power This docking station requires the CMAC 5090 universal power supply Ordering information e CMAC 5068 Docking station CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 C
20. corresponding Z2 ATEX Zone 2 certified models in areas known to be non hazardous Please consult your site safety officer for clarification Accessories for discontinued SKF Microlog models For a list of accessories available for discontinued SKF Microlog models refer to the section Accessories for obsolete products gt page 95 aKF Contents Accelerometers Cables Hardware Miscellaneous accessories aKF SKF the knowledge engineering company From one simple but inspired solution to a misalignment problem in a textile mill in Sweden and fifteen employees in 190 SKF has grown to become a global industrial Knowledge leader Over the years we have built on our exper tise in bearings extending it to seals me chatronics services and lubrication systems Our knowledge network includes 46 000 employees 15 OOO distributor partners offices in more than 130 countries and a growing number of SKF Solution Factories around the world Research and development We have hands on experience in over forty industries based on our employees know ledge of real life conditions In addition our world leading experts and university part ners who pioneer advanced theoretical research and development in areas includ ing tribology condition monitoring asset management and bearing life theory Our ongoing commitment to research and development helps us keep our customers at the forefront of thei
21. straight Ordering information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5036 CH1 signal input straight extension cable 5 m 16 4 ft 35 CMAC 5037 CHI signal input straight ex tension cable 10 m 32 8 ft The CMAC 5037 cable which is used for the CHI signal input is a straight extension cable that is 10 m 32 8 ft long This cable can be used with single channel and triax sensors Specifications e Connectors Fischer type 103 six pin female to Fischer type 103 six pin male e Length 10 m 32 8 ft straight Ordering information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5037 CH1 signal input straight extension cable 10 m 32 8 ft 36 CMAC 5043 Tachometer straight exten sion cable 5 m 16 4 ft The CMAC 5043 straight extension cable is for use with the CMAC 5030K and CMAC 5030K Z2 laser tachometer kits This cable is 5 m 16 4 ft long and can be used in conjunction with the CMAC 5211 cable Specifications e Connectors Fischer type 103 seven pin female to Fischer type 103 seven pin male e Length 5 m 16 4 ft straight Ordering information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5043 Tachometer straight extension cable 5 m 16 4 ft aKF CMAC 5044 Tachometer straight
22. 4 mm 1 00 in t 25 4 mm 1 00 in Ordering information e CMSS 793 CA CSA approved general purpose industrial accelerometer 1 4 28 mounting studs are provided Calibration sensitivity is provided on each accelerometer package with nominal sensitivity etched on each unit Optional accessories e CMSS 908 MD Medium duty magnetic base aKF 23 CMSS 793 EE ATEX approved intrinsically safe IS general purpose industrial accelerometer The CMSS 793 EE is an industrial standard acceleration sensor with atop exit C5015 two pin connector and agency approvals Features e ntrinsically safe certification e Ground isolated e Rugged construction e Corrosion resistant and hermetically sealed for installation in high humidity areas e ESD protection e Reverse wiring protection Specifications Dynamic e Sensitivity 5 25 C 75 F 100 mVg e Measurement range 80 g peak e Frequency range 5 1 5 to 5 000 Hz 10 1 0 to 7 000 Hz 3 dB 0 5 to 15 000 Hz e Amplitude non linearity 1 e Resonance frequency 25 kHz e Transverse sensitivity lt 5 of axial e Temperature response 50 C 60 F 10 120 C 250 F 5 Electrical e Power requirements Voltage source 18 to 30V DC Constant current diode 2 to 10 mA e Electrical noise Broadband 2 5 Hz to 25 kHz 600 ug Spectral 10 Hz 8 ug Hz 100 Hz 5 ug Hz 1000 Hz 5 ug Hz e Output imp
23. 70 F Physical e Dimensions 110 3 x 19 5 x 72 0 mm 4 34 x 0 77 x 2 83 in e Weight 290 g 10 2 oz Protection Minimum Typical Maximum e Over current A 5 00 8 33 8 89 e Short circuit A 14 82 33 33 43 61 e Over voltage V 8 65 8 70 8 75 e Under voltage V 4 40 4 60 4 76 Approvals e Emissions EN61000 6 4 2001 Severity Level Class A e Immunity EN61000 6 2 2001 Severity Level Class A e CSA Class Division 2 Gas groups A B C and D Canadian and US standards e Transportation UN Directive ST SG AC 10 11 Rev 3 e Equivalent Lithium content 3 96 g 0 1397 oz Ordering information e CMAC 5070 Battery aKF 71 CMAC 5092 Battery ATEK CMKA 45 CMXA 45 75 Z2 paa ha BP45 CC CMXA 48 Raw c Tiy lisa e AT 8 Yah The 7 2 V Lithium lon 6 600 mAh rechargeable battery pack provides customers with eight CMXA 48 80 Z2 hours of continuous data collection or 10 hours ee CMXA 51 IS MO EA Sai hd idle Charging time is six hours The battery can E YES be charged in the instrument through the docking station CMAC 5068 CMXA 75 CMXA 80 Specifications Electrical e Nominal voltage 7 2 V e Nominal capacity 47 5 Wh 6 6 Ah e Operating time Eight hours continuous data collection 10 hours idling in a process product e Charge time Six hours in suspend mode Environmental e Temperature range Charging 10 to 45 C 50 to 115 F
24. Reflective tape strips CMAC 5216 Mini mounting tripod CMAC 5214 Tachometer interface cable 2 m 6 56 ft aKF CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Compact laser CMAC 5215 mounting Reflective tape strips tachometer bracket CMAC 5216 mini CMAC 5214 tachometer interface cable mounting tripod Ordering information e CMAC 5030K Z2 Laser tachometer kit ATEX certified Each kit includes a compact laser tachometer mounting bracket cable and mini tripod Optional accessories e CMAC 5215 Mounting bracket e CMAC 5216 Mini mounting tripod 49 CMAC 5056 CMAC 5057 CMAC 5058 Modal analysis hammer kit Features e Freguency range up to 8 kHz e Peak force 2 200 N 500 lb ft e Output 2 25 mV N 10 mV lb ft e Mass extender to provide additional force These calibrated modal hammer kits may be used for impulse testing of the dynamic behavior of mechanical structures by striking the object with the hammer and measuring the resulting response with the accelerom eter The hammer imparts a constant force over a broad frequency range which depends on the type of tip used The hammer has an integral constant current quartz force sensor mounted on the striking end of the hammer head The sensor converts the impact force into electrical signal for display and analysis It is designed with rigid quartz crystals and a built in microelec
25. V Hz 10 Hz 700 ug Hz 100 Hz 180 ug Hz 1 kHz 64 ug Hz aKF Environmental Overload limit shock 98 100 m s pk 10 000 g pk Temperature range operating 55 to 120 C 65 to 250 F Base strain sensitivity lt 0 002 a u strain Physical Size hex x height 7 1 x 17 3 mm 0 28 x 0 68 in Weight 1 5 g 0 05 oz Sensing element Quartz Sensing geometry Shear Housing material Titanium Sealing Welded hermetic Electrical connector 5 44 coaxial Electrical connection position Top Mounting thread 5 40 male Mounting torque 0 90 to 1 35 Nm 9 to 12 in lbs CMAC 5056 CMAC 5057 CMAC 5058 Hammer Dynamic Sensitivity 1544 2 25 mV N 10 mV Ib ft Measurement range 2 200 N peak 500 Ib ft peak Impact Tips Frequency range Hard tip 10 dB 8 kHz Medium tip 10 dB 2 5 kHz Soft tip 10 dB 375 Hz Super soft tip 10 dB 200 Hz Resonance frequency gt 22 kHz 51 Kit contents The CMAC 5056 and CMAC 5057 hammer kits each contain an accelerometer while the CMAC 5058 hammer kit does not The CMAC 5056 hammer kit can be used on structures with a mass of 210 g 7 6 oz and above The CMAC 5057 hammer kit can be used on structures with a mass of 56 g 2 oz and above The accelerometers that are included with the CMAC 5056 and CMAC 505 kits are constant current low impedance voltage mode sensors Microelectronic built in amplifiers sta
26. complete kit that provides the necessary transducers magnetic bases A B switch cables trial weight kit precision elec tronic balance scale and more all packaged in a rugged watertight hard case that makes bal ancing easier and more accurate With the flip of a switch two chan nels of vibration data can be input into the SKF Microlog This elimi nates the need to keep moving the vibration sensor back and forth between balance planes A variety of adapters are included so that you can hookthe SKF Microlog to other sensor sources such as on line systems and velocity probes The CMCP 850 is a complete kit for the SKF Microlog In short all you need to add is an SKF Microlog and you are ready to balance pumps fans motors couplings small turbines and more Field balancing kits are available with either the optical or laser phase kits or a laser tachometer kit Kit contents CMCP 850 01 with Optical Sensor kit includes e CMSS 6155XK U CE Optical phase reference kit with universal power supply CMCP 850 02 with Laser Sensor kit includes e CMSS 6195AX K Laser phase reference kit with universal power supply CMCP 850 03 with Laser Sensor kit includes e CMAC 5030K Laser tachometer kit SKF Microlog powered aKF CMXA 45 CMXA 45 75 Z2 O CMXA 48 CMXA 48 80 Z2 CMXA 51 IS O CMXA 70 44 CMXA 75 CMXA 80 CMCP 850 01 CMCP 850 02 CMCP 850 03 kits include e CMSS 2100 Accelerometers two
27. e Pull strength 16 kg 35 Ib e Outside diameter 25 mm 1 0 in e Mount 1 4 28 tapped hole Metric studs available e Knurled gripping edge aKF Dimensions 12 2 mm 0 48 in A 23 6 mm 0 93 in 1 2 in hex 10 32 coaxial connector Y 10 32 12 4 mm 0 49 in mounting hole Ordering information e CMSS 732A Small diameter high frequency accelerometer A 10 x 32 mounting stud is provided Calibration sensitivity is provided on each accelerometer package with nominal sensitivity etched on each unit Optional accessories e CMSS B13 Magnetic base mounting e CMAC 5061 High frequency accelerometer cable 21 CMSS 93 CA CSA approved general purpose industrial accelerometer The CMSS 93 CA is an industrial standard acceleration sensor with a top exit two pin connector and agency approvals Features e Class Division 1 certification e Ground isolated e Rugged construction e Corrosion resistant and hermetically sealed for installation in high humidity areas e ESD protection e Reverse wiring protection Specifications Dynamic e Sensitivity 5 25 C 75 F 100 mVg e Measurement range 80 g peak e Frequency range 5 1 5 to 5 000 Hz 10 1 0 to 7 000 Hz 3 dB 0 5 to 15 000 Hz e Amplitude non linearity 1 e Resonance frequency 25 kHz e Transverse sensitivity x 5 of axial e Temperature response 50 C 60 F 10 120 C 250 F 5 El
28. locations qty 100 used with the SKF Marine Condition Monitoring kit aKF 13 CMSS 2114 K High freguency accelerometer kit The CMSS 2114 K is a high freguency accelerometer kit that includes a high freguency cable with an adhesive mounting base Specifications Dynamic e Sensitivity 15 10 mVg e Measurement range 500 g peak e Frequency range 3 dB 5 to 60 000 Hz e Non linearity x 1 e Resonance frequency 2 95 kHz e Transverse sensitivity lt 5 Electrical e Power supply Voltage source 18 to 30 V DC Constant current diode 2 to 20 mA e Electrical noise Broadband 1 Hzto 10 kHz 0 002 g RMS Spectral 10 Hz 160 ug Hz 100 Hz 40 ug Hz 1 kHz 15 ug Hz 10 kHz 10 ug Hz e Output impedance x 100 0 e Bias output voltage 8 to 12 V DC e Discharge time constant 0 02 to 0 06 s Environmental e Temperature range 55 to 120 C 65 to 250 F e Shock limit 5 000 g peak e Base strain sensitivity lt 0 05 g u Physical e Dimensions See drawing e Weight 6 g 0 2 oz e Mounting thread 10 32 male e Mounting torque 1 13 to 2 25 Nm 10 to 20 in lbs e Case material Stainless steel e Sealing Welded hermetic e Sensing element design Ceramic shear e Connections 5 44 coaxial top Note All specifications are at room temperature unless otherwise specified 14 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44
29. low noise level over a wide temperature range Meets stringent CE EMC requirements Low profile with captive mounting bolts 1 4 28 M6 x 1 00 or M8 x 1 25 provided Corrosion resistant and hermetically sealed Reverse polarity wiring protection Specifications Dynamic Sensitivity 100 mVg Sensitivity precision 10 at 25 C 75 F Measurement range 80 g peak Frequency range 10 1 0 to 5 000 Hz 3 dB 0 7 to 10 000 Hz Amplitude linearity 1 Resonance frequency mounted minimum 22 kHz Transverse sensitivity lt 5 of axial 16 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS O CMXA 70 44 CMXA 75 CMXA 80 Electrical Power requirements Voltage source 18 to 30 V DC Constant current diode 2 to 10 mA recommended 4 mA Electrical noise 2 0 Hz 20 ug Hz Output impedance 100 Q Bias output voltage 12 V DC Grounding Case isolated internally shielded Environmental Temperature range 50 to 120 C 60 to 250 F Vibration limit bOO g peak Shock limit 5 000 g peak Base strain sensitivity 200 ug ustrain Electromagnetic sensitivity equivalent g maximum 70 ug gauss CE According to the generic immunity standard for Industrial Environment EN50082 2 Acceptance criteria The generated false equivalent g level under the above test conditions should be less than 2 mg measured peak to peak aKF Physical Dimensions S
30. officer before use in a hazardous area Specifications e Connectors Fischer three pin to BNC e Length 2 m 6 56 ft coiled Ordering information e CMAC 5117 Trigger coiled cable 42 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 15 CMXA 70 44 CMXA 75 CMXA 80 CMAC 5201 Serial communication cable The CMAC 5201 cable has nine pins female at both ends that all connect straight through It is required for uploading down O loading data between the host computer and the SKF Microlog For uploading to laptop computers with a USB connection there is no USB to Serial cable available from SKF however an after market USB adapter may be purchased at most electronics stores or via the web Specifications e Connectors Nine pin female to nine pine female e Length 2 m 6 56 ft Ordering information e CMAC 5201 Serial communication cable CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 aKF CMAC 5404 Strobe light input straight cable The CMAC 5404 cable is used for inputto the CMSS 6165 strobe light from the SKF Microlog Specifications e Connectors Fischer type 103 seven pin to input adapter e Length 2 m 6 56 ft straight Ordering information e CMAC 5404 Strobe light input straight cable aKF CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5406 Strobe light
31. output straight cable The CMAC 5406 cable is used for output from the CMSS 6165 strobe light to the SKF Microlog Specifications e Connectors Fischer type 103 seven pin to output adapter e Length 2 m 6 56 ft straight Ordering information e CMAC 5406 Strobe light output straight cable CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 43 CMAC 5093 Signal input straight cable microphone cable The CMAC 5093 cable has a BNC connector on one end to connect to the CMAC 5091 microphone and a Fischer connector on the other end to connect to the SKF Microlog This cable is used in the SKF Microlog ldler Sound Monitor kits Specifications e Connectors Fischer type 103 six pin to BNC e Length 51 cm 20 in coiled CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Ordering information e CMAC 5093 Signal input straight cable microphone cable 44 aKF Hardware Infrared thermometer CMAC 4200 K SL 46 Laser tachometer kit CMAC 5030K 48 Laser tachometer kit ATEX certified CMAC 5030K Z2 49 Modal analysis hammer kit CMAC 5056 CMAC 5057 CMAC 5058 50 Modal analysis hammer kit CMAC 5059 54 Microphone with integral preamplifier kit CMAC 5084
32. phase reference kit consists of a remote optical sensor equipped with a steady state DC light source and photo detector an interface module on off switch BNC connectors internal recharge able batteries and a recharger input A universal plug in charger module is also supplied Standard camera tripods user supplied mounting brackets or the optional magnetic holder with movable arm CMSS 6156 may be used for mounting aKF Specifications Interface module Power source Four rechargeable Nickel Metal Hydride NIMH AA batteries provide up to 40 hours of continuous operation com plete recharge requires four hours Output signals TL positive inverting pulse O to 5 V TL negative non inverting pulse 5 to OV switch selectable Bandwidth O to 100 kHz Output connectors BNC connector female Pulse width Determined by size of reflective marker and rotational speed of equipment being monitored Operating temperature O to 50 C 30 to 120 F Weight 235 g 8 3 oz Dimensions 127 x 64 x 25 mm 5 0 x 2 5 x 1 0 in Remote optical sensor Speed range 1 to 250 000 r min Operating envelope Up to 0 9 m 3 ft and 45 from reflective target Illumination source Visible red LED 5 V DC at 30 mA Output signal 5 to O V DCTTL compatible pulse On target indicator Green LED on end cap Material 303 stainless steel Lens Acrylic plastic Cable length 2 4 m 8 ft from sensor to interface module Operating tempera
33. provided Calibration sensitivity is provided on each accelerometer package with nominal sensitivity etched on each unit Optional accessories e CMSS 908 MD Medium duty magnetic base 25 CMSS 908 MD Medium duty magnetic base The CMSS 908 MD is a multi purpose magnetic base designed for industrial vibration monitoring applications The low profile magnet has a 1 4 28 mounting hole to allow compatibility with SKF acceler ometers and provides a solid mechanical connection to the machine Specifications e Diameter 35 mm 1 38 in e Height 19 mm 0 75 in e Mounting hole 1 4 28 e Pull strength 23 kg 50 lbs Accelerometer compatibility The CMSS 908 MD medium duty magnetic base is compatible with the following accelerometers CMAC 4370 Triax accelerometer CMSS 2200 CMSS 2200 M8 General purpose low profile side exit industrial accelerometer e CMSS 2210 Intrinsically safe IS industrial accelerometer e CMSS 93 CA CSA approved general purpose industrial accelerometer e CMSS 793 EE ATEX approved intrinsically safe IS general purpose industrial accelerometer 26 Dimensions CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 1 4 28 mounting hole 19 0 mm 0 75 in Ordering information e CMSS 908 MD Medium duty magnetic base 35 0 mm 1 40 in aKF Cables 1 Cable recommendations
34. side exit industrial accelerometer with MIL C 5015 two pin connector M8 mounting studs provided Calibration sensitivity and nominal sensitivity are provided for each accelerometer package Optional accessories e CMSS 908 MD Medium duty magnetic base 17 CMSS 2210 Intrinsically safe IS industrial accelerometer The CMSS 2210 industrial accelerometer is intrinsically safe and is ATEX and IECEx Group and Il approved Specifications Dynamic e Sensitivity 10 100 mVg nominal at 80 Hz e Frequency range 2 Hz to 10 kHz 5 3 dB at 0 8 Hz e Resonance frequency mounted nominal 18 kHz e Transverse sensitivity 5 Electrical e Constant current diode 0 5 to 8 mA e Electrical noise 0 1 mg maximum e Bias output voltage 12 V DC nominal Environmental e Temperature range T4 55 to 115 C 65 to 240 F T6 55 to 65 C 65 to 150 F Physical e Dimensions See drawing e Weight 100 g 3 5 oz e Mounting torque 8 Nm 70 8 in lbs e Case material Stainless steel Sealing IP 67 Isolation Base isolated Connections MIL C 5015 style two pin e Recommended cables For CMXA 51 15 CMAC 5115 For ATEX Zone 2 CMXA 45 48 75 80 CMAC 5209 e Recommended magnetic base CMSS 908 MD 18 CMXA 45 CMXA 45 75 22 CMXA 48 CMXA 48 80 Z2 CMXA 51 15 CMXA 70 44 CMXA 75 CMXA 80 aKF Certifications Dimensions e Group Baseefa02ATEX0245X and IECEx BAS 08 0013X E
35. 0139 AUDIO CMSS 50156 CMS 50157 EMSs 50152 15 CMs 50127 CE CMSS 50221 CMSS 50236 CMSS 50238 CMSS 50247 2 OMss5027 220 CMSS50275 CE MES 50280 LE CMSS 50288 MES 50pa CMSS 60139 04 MES 6135E CMSS 6145K 1 EMSS50155K U CE NIES els SI UCE CMSS 6160 M5SO165 SPE CMSS 6165K VA CMSS6187 CE CMSS 6190 BNC CMSS 6195A K aKF Description Accelerometer adapter for SKF Microlog SKF MARLIN 1 4 28 stud Cable SKF Microlog PC direct access Lens savers for SKF Microlog 5 Adapter BNC to LEMO for CMSS 6190L Screen protector Fischer connector cover set Power supply non IS Adapter cable 3 5 mm female audio to BNC connector CMVA 55 CMVA 60 CMVA 65 Audio headphones with 3 5 mm male audio connector CMVA 55 CMVA 60 CMVA 65 Strobe light kit for SKF Microlog Analyzer GX series CMXA 70 and CMVA series Audio headphone strobe adapter kit includes adapter cables and headphones Audio headphone strobe adapter includes adapter and cables no headphones General purpose two pin industrial accelerometer 100 mV g with 1 4 28 and M8 mounting stud Industrial accelerometer kit includes CMSS 908 MD magnetic base and CMSS 60139 04 stinger Cable SKF Microlog to CMSS 786M Cable SKF Microlog to CMSS 2100 2106 2200 2206 787A 793 786A two pin MIL High temperature accelerometer charge mode 260 C 500 F Cable CMVA 60 CMVA 10 CMVA 40 to support module 120 cm 4 ft Cable su
36. 6 006 164 US 6 199 422 US 6 202 491 US 6 275 781 US 6 489 884 US 6 513 386 US 6 633 822 US 6 789 025 US 6 792 360 W0 2003 048714 US 5 633 811 US 5 870 699 US 6 437 692 US 7 103 511 US 7 697 492 PUB CM P1 11643 4 EN July 2014 skf com
37. 72 Universal power supply non IS CMAC 5090 73 Battery CMXA 51 15 CMAC 5105 73 Power supply CMXA 51 15 CMAC 5110 74 Strobe light power supply CMAC 5405 74 aKF 69 CMAC 5031 Battery CMXA 45 CMXA 45 75 Z2 CMXA 48 The 7 2 V Lithium lon 2 6 Ah rechargeable battery pack provides customers with eight hours of continuous data collection or 20 hours idle The charging time is 2 5 hours CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 Specifications CMXA 80 Electrical e Nominal voltage 7 2 V e Nominal capacity 2 6 Ah e Operating time Eight hours continuous data collection 20 hours idling in a process product e Charge time 2 5 hours Environmental e Temperature range Charging O to 45 C 30 to 115 F Rapid charge 10 to 45 C 50 to 115 F Discharging 20 to 60 C 5 to 140 F Storage 1 week 20 to 50 C 5 to 120 F 6 months 20 to 35 C 5 to 95 F Physical e Dimensions 70 5 x 38 5 x 20 5 mm 2 78 x 1 52 x 0 81 in e Weight 103 g 3 6 oz e Drop tested to MIL810E 2 m 6 6 ft when installed in a CMXA 70 or CMXA 75 Protection Minimum Typical Maximum e Over current A 5 2 e Short circuit A 3 5 e Over voltage V 8 50 8 6 8 70 e Under voltage V
38. F Microlog to measure the absolute phase of a vibration signal 60 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 The phase angle measuring process works by aiming the sensor s light beam using the optical phase reference sensor at the reference mark on the rotating shaft This establishes the zero phase reference relative to the vibration signal component The vibration transducer produces a complex vibration signal for the process The optical phase reference sensor sends out a phase reference signal to the SKF Microlog that is synchronous with the shaft speed The SKF Microlog then reports the magnitude of the vibration component and its phase angle in relation to the vibration transducer Interface module The interface module provides an interface between the optical phase reference sensor and the SKF Microlog It also provides power to the sensor The optical phase reference sensor can typically oper ate for 40 hours continuously using the interface modules internal rechargeable batteries or indefinitely from the external recharger power supply when connected to the interface module Features e Single pulse per revolution T TL trigger source e Positive and negative pulse outputs e Self contained e Rechargeable batteries e Green LED on optical sensor indicates ON target operation e Remote wake up with Wireless Monitoring System V T The optical
39. MXA 75 CMXA 80 aKF CMAC 5074 Screen protector The CMAC 5074 screen protector helps keep the LCD plastic cover of the SKF Microlog from scratching CMAC 5074 includes a set of five non glare self adhesive screen pro tectors CMKA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 6139 Screen protector The CMAC 6139 screen protector helps keep the LCD plastic cover of the SKF Microlog from scratching CMAC 6139 includes a set of five replacement screen protectors CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Ordering information e CMAC 5074 Screen protector includes five aKF Ordering information e CMAC 6139 Screen protector includes five 85 CMAC 5077 SD memory card 4 GB CMAC 5077 is a 4 GB SanDisk SD memory card for use in the SKF Microlog Note that the SKF Microlog series only supports SD cards up to 16 GB the SD memory card is the only CSA agency approved memory card for the SKF Microlog Specifications e 33V DC e 10 uF maximum e 4 CB A 4 GB version of the SD card is included with each SKF Microlog kit CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Use of any other brand of SD card will result in invalidation of the instruments CSA agency certification CMAC 5251 Stylus IS The CMAC 5251 stylus for the SKF Microlo
40. NC connector at the other end This lightweight cable is also used in the CMAC 5056 CMAC 5057 and CMAC 5058 modal analysis hammer kits Note Refer to CMAC 5088 for a heavy duty version of this cable Specifications CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e Connectors Fischer type 103 six pin CH1 I P to BNC e Length 1 m 3 ft straight Ordering information e CMAC 5023 Signal input straight cable 38 CMAC 5032 Power Trigger splitter straight cable The CMAC 5032 cable allows the connection of the tachometer instrument power and USB communications via the CMAC 5095 cable simultaneously Specifications e Connectors One Fischer type 103 seven pin plug to two Fischer type 103 seven pin sockets e Length 30 cm 11 8 in e Cable Eight core 24 AWG screened cable Ordering information e CMAC 5032 Power Trigger splitter straight cable CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 aKF CMAC 5078 CMAC 5082 CMXA 45 CMXA 45 Audio headphone straight USB A to B straight cable CMXA 45 75 Z2 CMXA 45 75 Z2 cable CMXA 48 CMXA 48 The CMAC 5078 cable connects the qs RE The CMAC 5082 USB cable is used to con cMXA 48 80 22 CMAC 5403 headphones to the SKF nect the CMAC 5068 docking station to the Microlog CMXA 51 IS PC CMXA 51 IS CMXA 70 44 CMXA 70 44 Specifications CM
41. S CMAC 5130 Pull force gauge adapter SK40 MAS CMAC 5132 Pull force gauge adapter 32A HSK CMAC 5133 Pull force gauge adapter 40A HSK CMAC 5134 Pull force gauge adapter 50A HSK CMAC 5135 Pull force gauge adapter 63A MEAN CMAC 5136 Pull force gauge adapter 80A HSK CMAC 5132 32A HSK adapter aKF SKF spindle assessment accessories continued CMAC 5137 Run out gauge The CMAC 5137 analog run out gauge vipp indicator is used together with the universal magnetic foot to measure tool nose run out in the Spindle Assessment kit and the Spin dle Test module The run out gauge can measure in both directions and can enable to turn the outer ring for a zero setting CMAC 5137 includes an adapter for an 8 mm fixture and also includes a carrying case Ordering information e CMAC 5137 Run out gauge aKF CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5138 Depth micrometer The CMAC 5138 depth micrometer is used to measure ejection measure EM test on spindle tool noses in the Spindle Assessment kit and the Spindle Test module CMAC 5138 also includes a carrying case Accessories are available to extend the Spindle Assessment kit utilization and to maximize the utilization of the Spindle Test module firmware Specifications Accuracy DIN863 2 e Resolution 0 01 mm 0 0004 in e Scale 25 0 mm 0 98 in e Pitch 0 5 mm 0 02 in e F
42. XA75 Specifications dms e Connectors Fischer type 103 seven pin to e Connectors USB TypeA to USB Type B female audio e ERAS e Length 2 m 6 56 ft straight xd oe e Length 20 cm 7 9 in straight Ordering information Ordering information e CMAC 5078 Audio headphone straight cable e CMAC 5082 USB A to B straight cable aKF 39 CMAC 5087 Temperature gun interface straight cable O The CMAC 5087 cable is used to connect the CMAC 4200 K SL infrared thermometer to the SKF Microlog Specifications e e Connectors Fischer type 103 six pin to i o Input adapter e Length 1 5 m 4 9 ft straight Ordering information e CMAC 5087 Temperature gun interface straight cable 40 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5088 Signal input straight cable The CMAC 5088 cable is a heavy duty ver sion of the CMAC 5023 cable The CMAC 5088 cable connects to the SKF Microlog CH1 or CH2 signal input connector at one end using the input connector s CH1 input pin and to any male BNC connector at the other end Note Refer to CMAC 5023 for a lightweight version of this cable Specifications e Connectors Fischer type 103 six pin CH1 I P to BNC e Length 2 m 6 56 ft straight Ordering information e CMAC 5088 Signal input straight cable CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80
43. ables recommended for accelerometers Cable model number u gt O wh ON vi N LO ON ON ON eo No No v1 O O O O O O v1 ON ON ON LO LO LO LO LO LO LO Accelerometer model number Accelerometer description 2 pa CMAC 4370 K Triax accelerometer kit CMSS 2114 K High frequency accelerometer kit O CMSS 2200 General purpose low profile side exit industrial accelerometer O CMSS 2200 M8 General purpose low profile side exit industrial accelerometer o e e EMSS22d0 Intrinsically safe IS industrial accelerometer 6 EMS 12A Small diameter accelerometer CMSS 793 CA CSA approved general purpose industrial accelerometer o e CMSS 793 EE ATEX approved IS general purpose industrial accelerometer Cables recommended for hardware etc Cable model number on mM t cl N co N co Ln ot n t o N 4 o o r 00 co CO O ed ed O O O O O O O O O O O O N N N t M LO LO LO LO LO LO LO LO LO LO LO LO LO LO LO Hardware d a 4 4 d X4 X4 Xd SS 7H model number Product description 2 8 2 2 2 2 8 2 2 2 8 8 2 2 Z CMAC 4200 K SL Infrared thermometer o CMAC 5030K Laser tachometer kit o o CMAC 5030K Z2 Laser tach kit ATEX certified o o CMAC 5056 Modal analysis hammer kit e e CMAC 5057 Modal analysis hammer kit O Oo CMAC 5058 Modal analysis hammer kit e e CMAC 5068 Docking station o CMAC 5084 Microphone with integral preamplifier kit 8 e CMAC 5090 Universal power supply O CMAC 5403 Audio headse
44. ations e Connectors Fischer type 103 six pin to a Microdot e Length 3 m 10 ft straight Ordering information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5062 High frequency accelerometer straight cable aKF CMAC 5079 Splitter four channel straight cable The CMAC 5079 cable is used for connecting to either CH1 or CH2 on the CMXA 80 and CMXA 48 If connected to CH1 lead A gives channel 1 and lead B gives channel 4 If con nected to CH2 lead A gives channel 2 and lead B gives channel 3 Specifications e Connectors Two Fischer type 103 six pin CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 female sockets to one Fischer type 103 six pin male e Length 45 cm 1 5 ft straight Note Two cables are required to collect four channel measurements Note For CMXA 45 and CMXA 75 this cable can be used in CH2 only to give three single axis simultaneous accelerometer inputs A single acceler ometer is connected to CH1 giving channel 1 then the cable into CH2 giv ing the same inputs as for CH2 of the CMXA 80 Ordering information e CMAC 5079 Splitter four channel straight cable 31 CMAC 5115 ATEX certified accelerometer coiled cable The CMAC 5115 cable is ATEX certified and is used to connect the accelerometer to the signal connector Specifications e Connectors Fischer type 102 f
45. aximum Cable Fischer seven pin type 103 to four pin socket 2 m 6 56 ft Wavelength 635 mm 25 in Angle of incidence 80 Speed range 0 1 to 250 000 r min Power input 5 V DCor 8 24 V DC versions at 30 mA typically Operating temperature 10 to 40 C 15 to 105 F IP rating IP 67 Housing types M20 threaded or plain body plus fixing slots Connections Integral connector Dimensions 70 x 20 mm 2 76 x 0 79 in Weight 70 g 2 5 oz Kit contents e Compact laser tachometer e CMAC 5215 Mounting bracket e Reflective tape strips e CMAC 5216 Mini mounting tripod e CMAC 5214 Tachometer interface cable 2 m 6 56 ft 48 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5215 mounting bracket Compact laser Reflective tape strips tachometer CMAC 5214 tachometer interface cable CMAC 5216 mini mounting tripod Ordering information e CMAC 5030K Laser tachometer kit Each kit includes a compact laser tachometer mounting bracket cable and mini tripod Optional accessories e CMAC 5215 Mounting bracket e CMAC 5216 Mini mounting tripod aKF CMAC 5030K Z2 Laser tachometer kit ATEX certified The CMAC 5030K Z2 laser tachometer kit contains a small tachometer that is ATEX certified the sensor is designed for use in hazardous areas with certified hazardous area equipment This kit is primarily designed for phase re
46. battery voltage 2 6 5 V e Battery life Approximately 120 hours with alkaline battery e Overload indication Red LED indicates input greater than the selected range Jaw opening 31 mm 1 2 in e Maximum conductor size One 30 mm 1 18 in conductor or Two 24 mm 0 95 in conductors or Two bus bars 31 5 x 10 0 mm 1 24 in x 0 40 in Dimensions 224 x 97 x 44 mm 8 80 x 3 82 x 1 73 in Weight 440 g 15 oz Vibration Test per IEC 68 2 6 Frequency range 5 to 15 Hz Amplitude 1 50 mm 0 06 in 15 to 25 Hz Amplitude 1 00 mm 0 04 in 25to 55 Hz Amplitude 0 25 mm 0 01 in e Mechanical shock 100 6 test per IEC 68 2 27 Material e Output lead Double Reinforced insulated 1 5 m 5 ft e Handle Gray polycarbonate 4 ABS UL94 VO e Jaws Red polycarbonate UL94 VO Ordering information e CMAC 5208 AC DC current clamp includes an integral cable that connects directly to the SKF Microlog aKF CMCP 850 01 CMCP 850 02 CMCP 850 03 SKF Microlog Analyzer field balancing accessory kit Features e Two accelerometers with magnetic bases Choice of optical or laser phase reference kit 7 6 m 25 ft cables Precision electronic balance scale Large trial weight kit Packaged in a rugged watertight hard carrying case The SKF Microlog Analyzer field balancing acces sory kit contains all of the accessories necessary to perform in place field balancing of rotating machinery This is a
47. crolog models CMXA 45 and CMXA 75 e CMAC 5411 Idler sound monitor accessory kit for SKF Microlog models CMXA 80 and CMXA 48 kit does not contain CMAC 5142 adapter plate 88 CMAC 5091 l l T Microphone with preamplifier M CMXA 45 75 Z2 CMXA 48 The CMAC 5091 is a high frequency micro phone used with the idler sound monitor The constant current microphone enables acoustic type monitoring and is designed with a preamplifier The microphone is housed within the CMXA75 CMAC 5141 parabolic reflector and connect ed to the SKF Microlog via the CMAC 5093 microphone cable CMAC 5141 and CMAC 5093 are sold separately When used with the parabolic reflector the microphone can detect faulty idlers from up to 3 m 10 ft away CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 80 Note Refer to page 56 for specifications on the microphone Note The CMAC 5091 microphone Is the same microphone as supplied with the CMAC 5084 microphone kit The CMAC 5091 is sold separately as a replacement microphone for the idler sound monitor kit Ordering information e CMAC 5091 Microphone with preamplifier Optional availability The CMAC 5091 microphone is also available in the following two kits e CMAC 5410 Idler sound monitor accessory kit for SKF Microlog models CMXA 45 and CMXA 75 e CMAC 5411 Idler sound monitor accessory kit for SKF Microlog models CMXA 80 and CMXA 48 kit does not contain CMAC 5142 adap
48. curacy 1 of reading e Wide temperature range Graphic display View more information at a glance The CMAC 4200 K SL infrared thermometer automatically creates a graphic display of the last 10 temperature points measured using the maximum and minimum temperature values to establish the range Graphic display Alarm light Laser indicator Bar graph display Battery indicator dee Emissivity 46 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Specifications e Temperature range 30 to 900 C 25 to 1 600 F e Display resolution 0 1 C 0 2 F e Accuracy 1 of reading or 1 C 2 F whichever is greater at 23 C073 9E 2 C 14 F for targets below O C 32 F Repeatability 0 5 of reading or 1 C 2 F Response time 95 250 ms Spectral response 8 to 14 um Optical resolution 60 1 Ambient operating range 0 to 50 C 30 to 120 F Laser maximum 45 C 115 F Relative humidity 10 to 95 non condensing at up to 30 C 85 F Storage temperature 20 to 50 C 5 to 120 F without battery Analog output 1 mV C mV F Power Two 1 5 volt AA alkaline batteries Tripod mount 1 4 20 UNC Dimensions 200 x 170 x 50 mm 7 9 x 6 7 x 2 0 in Weight 480 g 22 oz aKF Kit contents CMAC 4200 Infrared thermometer 31784200 Nylon belt holster 31678902 Hard carrying cas
49. d a pouch that snaps to the back of the sleeve to hold cables etc These two pieces are only sold together Ordering information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5071 Soft case includes protective sleeve and pouch 80 CMAC 5111 Carrying pouch leather hazardous areas The CMAC 5111 carrying pouch is part of the SKF Microlog ATEX certification the unit may be in the carrying pouch while in use in a hazardous area Ordering information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5111 Carrying pouch leather hazardous areas aKF CMAC 5015 Rubber boot This protective rubber boot sleeve is designed to provide additional protection to the SKF Microlog While it is made out of heavy duty rubber the shoulder strap CMAC 5010 should also be purchased Note The CMAC 5015 is shipped with the SKF Microlog CMXA 51 IS to meet the IECEx requirements Specifications e Temperature range 60 to 130 C 75 to 265 F e Material Santoprene 8000 rubber e Weight 130 g 4 6 oz e Dimensions 20 0 x 12 5 cm 7 9 x 4 9 in Ordering information e CMAC 5015 Rubber boot aKF CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5026 Carrying case location for printer The CMAC 5026 carrying service case con tain
50. d for use with the CMAC 5030K laser tachometer kit It is a magnetic holder with a movable arm and remote optical sensor attachment hardware CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Specifications e Measurements Magnetic base 62 x 50 x 55 mm 2 44 x 1 97 x 2 17 in Height 240 mm 9 45 in e lamping force 80 N e Accessory mounting 355 6 mm 14 in camera type stud Compatibility The CMSS 6156 optical phase reference magnetic holder is compatible with the following kits e MSS 6155XK U CE Optical phase reference kit e CMSS 6195AX K Smart laser sensor tachometer kit Ordering information e CMSS 6156 Optical phase reference magnetic holder aKF 63 CMSS 6165K AX Strobe light kit The CMSS 6165 is a truly portable battery operated stro boscope that is suited for a wide range of industrial appli cations and is able to interface with the SKF Microlog CMXA series Sturdy and compact the strobe can be operated any where in the plant or field to permit visual inspection freeze motion phase shift studies and digital measure ment of rotary reciprocating or linear motion of various equipment while it is in operation The CMSS 6165 strobe light has a special tuning circuit that allows it to track vibration transducer accelerometer signals This capability makes it different from general purpose strobe lights It also has a narrow and wide bandwidth filter sel
51. d mount Temperature Operating 20 to 50 C 5 to 120 F Storage 30 to 60 C 20 to 140 F Humidity 90 relative humidity non condensing 67 Kit contents e CMSS 6195A Self powered sensor with smart laser sensor tachometer e CMAC 5211 BNC tachometer input cable e SLS CA BNC BNC to five pin DIN cable 2 5 m 8 ft e 115 230 V AC universal charger with adapter plugs e BNCto BNC coupling e CMSS T 5 Reflective tape CMSS 6195A self powered sensor with smart CMAC 5211 BNC tachometer input cable laser tachometer SLS CA BNC cable Universal charger with adapter plugs BNC to BNC coupling CMSS T 5 reflective tape Optional accessories Ordering information e CMSS 6195AX K Smart laser sensor tachometer kit includes a self powered sensor complete with a smart laser sensor tachometer 115 VAC 230 V AC universal charger with USA UK AUS and EURO adapter plugs 2 5 m 8 ft SLS CA BNC cable and reflective tape Optional accessories e CMSS 6156 Magnetic holder with movable arm and laser sensor attachment hardware e CMSS T 5 Reflective tape for use with the smart laser sensor tachometer 1 5 m x 12 7 mm 5 ft x 0 5 in CMSS 6156 magnetic holder 68 aKF Battery CMKA 45 CMKA 70 CMKA 75 CMAC 5031 70 Battery CMXA 48 CMXA 80 CMAC 5070 71 Battery ATEX CMXA 48 CMXA 80 CMAC 5092
52. dels CMXA 45 and CMXA 75 e CMAC 5411 Idler sound monitor accessory kit for SKF Microlog models CMXA 80 and CMXA 48 kit does not contain CMAC 5142 adapter plate aKF Ordering information e CMAC 5141 Parabolic reflector Optional availability The CMAC 5141 parabolic reflector is also available in the following two kits e CMAC 5410 Idler sound monitor accessory kit for SKF Microlog models CMXA 45 and CMXA 75 e CMAC 5411 Idler sound monitor accessory kit for SKF Microlog models CMXA 80 and CMXA 48 kit does not contain CMAC 5142 adapter plate 89 Idler sound monitor accessories continued CMAC 5142 Adapter plate The CMAC 5142 adapter plate with locking screw is used to attach the CMAC 5141 parabolic reflector to the back of the SKF Microlog models CMXA 45 and CMXA 75 only With the adapter plate attached to the back of the SKF Microlog the included velcro strap neatly holds the CMAC 5093 cable in place Ordering information e CMAC 5142 Adapter plate Optional availability CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 The CMAC 5142 adapter plate is also available in the following kit e CMAC 5410 Idler sound monitor accessory kit for SKF Microlog models CMXA 45 and CMXA 75 90 CMAC 5143 Wind jammer The CMAC 5143 wind jammer is used to reduce wind noise that the microphone may pick up With its integrated elastic band the
53. does not contain CMAC 5142 adapter plate aKF CMAC 5222 Labels for measurement locations The CMAC 5222 labels are used for marking measurement locations points during con dition monitoring These preprinted labels stickers are numbered with horizontal H vertical V and axial A designations Note These preprinted labels are also available in the SKF Marine Condition Monitoring kit CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 1H 1H 2H 1H 1H mo EIS oo oo 1H 1H iH 1H 1H wooo UU 1H 1H NAH ZH 2H mer EE oe ta oo 2H 2H 2H 2H 2H Ed La oe oy co 2H 2H 2H 2H 2H er EX E EN Eu 3H 3H 3H 3H 34 oo oo EU H AH 44 4H 4H woo EA Ka Ordering information e CMAC 5222 Labels for measurement locations qty 100 87 Idler sound monitor accessories CMAC 5078 Audio headphone straight cable The CMAC 5078 cable connects the CMAC 5403 audio headset to the SKF Microlog Specifications e Connectors Fischer type 103 seven pin to female audio e Length 20 cm 7 9 in straight Ordering information e CMAC 5078 Audio headphone straight cable Optional availability CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 The CMAC 5078 cable is also available in the following two kits e CMAC 5410 ldler sound monitor accessory kit for SKF Mi
54. e e Operators guide CMAC 4200 infrared thermometer 31784200 nylon belt holster aKF 31678902 carrying case Required as separate purchase e CMAC 5087 temperature gun interface cable CMAC 5087 temperature gun interface cable Ordering information e CMAC 4200 K SL Infrared thermometer with adapter operator s guide nylon holster and hard carrying case Optional accessories e 31784200 Nylon belt holster for infrared thermometer e 31678902 Hard plastic carrying case e CMAC 5087 Temperature gun interface cable 47 CMAC 5030K Laser tachometer kit The CMAC 5030K laser tachometer kit con tains a small tachometer for easy mounting Along with the tachometer this kit includes a bracket for mounting the tachometer directly to the SKF Microlog using the camera mount located on the bottom of the SKF Microlog The kit also includes a two meter cable to connect the tachometer to the SKF Microlog and a small tripod for a stationary mounting of the tachometer during the measurement The key features of this laser tachometer kit include e Operating frequency up to 250 000 r min e Long optical range up to 2 m 6 56 ft e Wide angle of operation up to 80 e Ontarget indicator standard e Protection rating IP 67 Specifications e Material Stainless steel body e Color Silver e Laser type Class 2 e Optical range 100 to 2 000 mm 0 33 to 6 56 ft e Power 1 mW maximum Current consumption 45 mA m
55. e acceler ometer at one location impacting the structure at one point and then moving the accelerometer to other points of interest When used with the FRF module the following modal parameters can be calcu lated and displayed e Apparent mass accelerance e mpedance Mobility e Stiffness Compliance Specifications Dynamic e Sensitivity 15 0 23 mV N 1 mV Ibf e Measurement range 22 240 N peak 5 000 Ibf peak e Resonant frequency gt 12 kHz e Non linearity x 1 54 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Electrical e Excitation voltage 20 to 30 V DC e Constant current excitation 2 to 20 mA e Output impedance 1000 e Output bias voltage 8 to 14 V DC e Discharge time constant 2 1 400 s Physical e Sensing element Quartz e Sealing Hermetic e Hammer mass 1 1 kg 2 4 Ib e Head diameter 5 1 cm 2 0 in e Tip diameter 5 1 cm 2 0 in e Hammer length 37 cm 14 5 in e Electrical connection position Bottom of handle e Electrical connector BNC jack Kit contents e Calibrated hammer e Super soft plastic gray tip e Medium plastic red tip e Hard plastic black tip e CMAC 5088 Cable BNC to Fischer six pin e arrying case aKF Hammer Gray hammer tip CMAC 5088 cable aKF Red hammer tip Black hammer tip Carrying case Ordering information e CMAC 5059 Modal hammer kit I
56. ection to discriminate fundamentals from harmonics The narrow bandwidth filter limits the influence of harmonics around the selected frequency providing a more stable phase reading The CMSS 6165 requires an input signal to synchronize the flash rate with an external source typically a vibration transducer in the tracking mode or optical pickup in the external mode Using a cable this signal is applied to the input Jack connector on the side of the strobe light The CMSS 6165 generates a tachometer signal available on the output Jack The CMSS 6165K AX strobe light kit is ideally suited for Balancing Inspection of high speed rotating parts Motion analysis or phase shift measurement Over speed trip tests On line coupling inspections r min r sec measurements All applications suited to a general purpose phase shifting stroboscope Specifications e ime base Ultra stable crystal oscillator e Display LCD with six numeric digits 12 7 mm 0 5 in high e ndicators Battery level on target TIME AUTO ALT TACH LOCK and EXT icons Knob adjustment Digital rotary switch with 36 detents per revolution velocity sensitive e Memory Last setting before power down is remembered and restored on next power up nine user flash rates can be set Output pulse 40 microseconds positive negative pulse menu selectable 3 3 V DC typical Input power Internal rechargeable batteries 6 V DC external AC recharger 115 to 230 VAC 64
57. ectrical e Power requirements Voltage source 18 to 30 V DC Constant current diode 2 to 10 mA e Electrical noise Broadband 2 5 Hz to 25 kHz 600 ug Spectral 10 Hz 8 ug Hz 100 Hz 5 ug Hz 1000 Hz 5 ug Hz e Output impedance x 100 0 e Bias output voltage 12 V DC e Grounding Case isolated internally shielded 22 CMXA 45 CMXA 45 75 Z2 TH AMA CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Environmental e Temperature range 50 to 120 C 60 to 250 F e Vibration limit 500 g peak e Shock limit 5 000 g peak e Base strain sensitivity 0 0005 g u strain Agency approvals e Canadian Standards Association CSA Class Division 1 Groups A B C D Class Il Division 1 Groups E F G Class IIl Division 1 aKF Physical Dimensions e Dimensions See drawing e Weight 112 g 4 0 oz TORINO WAWA e Mounting 1 4 28 tapped hole MIL C 5015 e ase material 316L stainless steel e Sealing Hermetic i e Sensing element design PZT ceramic compression e Connections Shell Ground Pin A Power Signal Pin B Common Output connector MIL C 5015 style two pin Mating connector R6 type m SKE e Recommended cable CMAC 5209 CMAC 5209 065 or CMAC 5209 10 e Recommended magnetic base CMSS 908 MD o 15 16 in hex 61 0 mm 2 42 in 1 4 28 mounting hole 25
58. edance lt 1500 Sensing element design Ceramic shear e Bias output voltage 8 to 12 V DC Connections e Discharge time constant x 0 3 s Molded integral cable top e Settling time within 1 of bias x 2 0 s Fischer type 103 six pin Environmental e Temperature range 55 to 120 C 65 to 250 F e Shock limit 5 000 g peak e Enclosure rating IP 68 12 aKF Optional accessories CMSS 908 LD magnetic mounting base CMAC 5220 quick connect mounting base used CMAC 5221 quick connect mounting stud used with the SKF Marine Condition Monitoring kit with the SKF Marine Condition Monitoring kit CMSS 908 LD magnetic mounting base specifications e Pull strength 67 N 15 Ib e Outside diameter 19 mm 0 75 in e Mount 1 4 28 tapped hole 1 4 28 mounting stud provided e Material Stainless steel CMAC 5222 labels for measurement locations used with the SKF Marine Condition Monitoring kit Ordering information e CMSS 2111 Small footprint accelerometer with an integrated cable and a magnetic mount CMSS 908 LD Optional accessories e CMSS 908 LD Magnetic mounting base with 1 4 28 stud e CMAC 5220 Quick connect mounting base with 1 4 28 threaded hole ies mounting used with the SKF Marine Condition Monitoring kit e CMAC 5221 Quick connect mounting stud with 1 4 28 threaded hole for machine mounting qty 50 used with the SKF Marine Condition Monitoring kit e CMAC 5222 Labels for measurement
59. edance x 100 0 e Bias output voltage 12 V DC e Grounding Case isolated internally shielded 24 CMXA 45 PAN CMXA 45 75 22 CMXA 48 my Lu ru Lm es a E x CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Environmental e Temperature range 50 to 120 C 60 to 250 F e Vibration limit 500 g peak e Shock limit 5 000 g peak e Base strain sensitivity 0 0005 g u strain Agency approvals e Intrinsically safe 50 to 120 C 60 to 250 F for ATEX Zone 0 1G Ex ia IICT4 Ga Note Must be installed per drawing 11535 revision F aKF Physical e Dimensions See drawing e Weight 112 g 4 0 oz e Mounting 1 4 28 tapped hole e ase material 316L stainless steel e Sealing Hermetic e Sensing element design PZT ceramic compression e Connections Shell Ground Pin A Power Signal Pin B Common Output connector MIL C 5015 style two pin Mating connector R6 type e Recommended cables For CMXA 51 15 CMAC 5115 ForATEX Zone 2 CMXA 45 48 75 80 CMAC 5209 e Recommended magnetic base CMSS 908 MD aKF Dimensions Two pin connector MIL C 5015 15 16 in hex 61 0 mm 1 2 42 in 1 4 28 mounting hole 25 4 mm 1 00 in EN mm 1 00 in Ordering information e CMSS 793 EE ATEX approved intrinsically safe IS general purpose industrial accelerometer 1 4 28 mounting studs are
60. ee drawing Weight 145 g 5 1 oz Mounting See ordering information Mounting torque 3 4 Nm 30 in lbs Case material 316L stainless steel Sealing Hermetic Connections Pin A Signal Power Pin B Common Mating connector CMSS 932 68LC or CMSS 932 68TL two pin IP 68 locking collar or twist lock Recommended cable Two conductor shielded fluorine based polymer jacket 100 pF m 30 pF ft CMAC 5209 CMAC 5209 065 or CMAC 5209 10 Recommended magnetic base CMSS 908 MD Note Specifications conform to ISA RP 37 2 1 to 64 and are typical values referenced at 25 C 75 F 24 V DC supply 4 mA constant current and 100 Hz Note This accelerometer is not recommended for use in hazardous environments aKF Dimensions 1 4 in socket head captive screw 26 0 mm m MODEL CMSS2200 40 0 mm 2 04 in MODEL CMSS2200 M8 IN 1 4 28 mounting thread 63mm 23 0mm__ CMSS 2200 M8 0 25 in 0 92 in M8 mounting thread 25 0 mm 1 00 in SUO 1 44 in g 53 0 mm ON Two pin connector MIL C 5015 Ordering information e CMSS 2200 General purpose low profile side exit industrial accelerometer with MIL C 5015 two pin connector 1 4 28 and M6 mounting studs provided Calibration sensitivity and nominal sensitivity are provided for each accelerometer package e CMSS 2200 M8 General purpose low profile
61. elerometer straight cable High frequency accelerometer straight cable Docking station Carrying case hard shell Battery Soft case Hand strap Shoulder strap Screen protector Fischer and audio connector cover set SD memory card 4 GB Audio headphone straight cable Splitter four channel straight cable USB Ato B straight cable SDIO and dock connector cover Microphone with integral preamplifier kit Temperature gun interface straight cable Signal input straight cable Universal power supply Microphone with integral preamplifier Battery ATEX o o0 86 66 00 00 00 00 OO CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 15 CMXA 70 44 CMXA 75 CMXA 80 Page 37 46 10 30 7 81 78 Jo 79 81 82 48 49 70 38 35 36 36 37 50 50 50 54 30 31 84 82 71 80 79 11 85 83 86 39 08 91 39 84 56 40 40 Ya 88 72 97 Product index continued Model number CMAC 5093 CMAC 5095 CMAC 5105 CMAC 5110 CMAC 5111 CMAC 5113 CMAC 5115 CMAC 5116 CMAC 5117 CMAC 5118 CMAC 5121 CMAC 5122 CMAC 5123 CMAC 5124 CMAC 5125 CMAC 5126 CMAC 5127 CMAC 5128 CMAC 5129 CMAC 5130 CMAC 5132 CMAC 5133 CMAC 5134 CMAC 5135 CMAC 5136 CMAC 5137 CMAC 5138 CMAC 5139 CMAC 5140 CMAC 5141 CMAC 5142 CMAC 5143 CMAC 5201 CMAC 5208 CMAC 5209 CMAC 5209 065 CMAC 5209 10 CMAC 5211 CMAC 5213 CMAC 5214 CMAC 5222
62. ence magnetic holder Strobe light kit Smart laser sensor tachometer Small diameter accelerometer CSA approved general purpose industrial accelerometer ATEX approved intrinsically safe general purpose industrial accelerometer Medium duty magnetic base CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Page 74 43 88 88 85 59 SA By 12 14 16 16 18 60 63 64 67 20 22 24 26 99 Please contact SKF USA Inc Condition Monitoring Center San Diego 52 1 Viewridge Court e San Diego California 92123 USA Tel 1 858 496 3400 e Fax 1 858 496 3531 Web www skf com cm SKF MARLIN and MICROLOG are registered trademarks of the SKF Group Loctite is a registered trademark of Henkel Corporation All other trademarks are the property of their respective owners SKF Group 2014 The contents of this publication are the copyright of the publisher and may not be reproduced even extracts unless prior written permission is granted Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct indirect or consequential arising out of the use of the information contained herein SKF reserves the right to alter any part of this publication without prior notice Patents US 4 768 380 US 5 679 900 US 5 845 230 US 5 854 553 US 5 992 237 US
63. ents e CMSS 6165 Strobe light e CMAC 5404 Cable Input to strobe light from the SKF Microlog e CMAC 5406 Cable output from strobe light to the SKF Microlog e Accelerometer input cable with BNC connector 2 m 6 56 ft e BNCto BNC union connector e CMAC 5405 Universal power supply recharger not compatible with older SKF Microlog models e 58 100 0290 Strobe light jacket and shoulder strap e 58 100 1650 Spare lamp e Protective carrying storage case e User manual CMSS 6165 strobe light CMAC 5404 strobe light input cable CMAC 5406 strobe light output cable Accelerometer input cable and BNC to BNC CMAC 5405 universal power supply recharger Carrying case open union connector 58 100 0290 strobe light jacket and shoulder 58 100 1650 spare lamp Carrying case closed strap aKF 65 Optional accessories CMSS 6165 SPC strobe light cover 66 aKF CMSS 6195AX K Smart laser sensor tachometer The CMSS 6195AX K smart laser sensor tachometer from SKF adds a powerful dimension to the capabilities of the SKF Microlog Portable Data Collector FFT Ana lyzer Ideal for measurement modes such as order tracking analysis and synchronous time averaging the smart laser sensor tachometer is an essential tool for the proac tive machinery analyst Features e Smart auto gain provides best performance in picking up target reflections Up to 19 8 m 65 ft maximum distance sensor to ta
64. eration during the measuring process All SK work holders from SK30 to SK60 DIN ISO ANSI and all HSK work holders according to DIN 69893 HSK A 32 B 40 to HSK A 125 B 160 can be used Features e Suitable for all types of clamping systems regardless of manufacturer e Exchanging adapters can be used for all tapered standards and sizes SK ANSI BT MAS HSK CAPTO and special standards The system is light compact very easy to use and suitable for difficult space conditions e he measured force is easily read on the LED display in kN even in difficult lighting conditions Power supply includes a standard 9 V DC battery Auto Power Off Gripping channel for automatic changing and positioning in the tool magazine e Automatic mode activates the pull force gauge by itself during the tool changing Adjustable tolerance range to simulate the range of the tool spindle 1 mm increments e Energy saving mode for long battery duration Internal memory stores up to 8 000 measurements machine ID date time pull force adjusted range e USB connection to download the internal memory and charge the integrated battery Operating temperature range between 15 to 35 C 60 to 95 F Maximum weight 1 5 kg 3 3 Ib aKF CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS O CMXA 70 44 CMXA 75 CMXA 80 io q Nomi Powis Cheek Wag If the pull force falls below a specified value that w
65. eter kit CMSS 793V General purpose industrial two pin velocity sensor OQ CMSS AD BLANK Stainless steel discs 10 discs per package minimum order 10 packages CMSS R2 2 J5A 10 Cable BNC to trigger source 300 cm 10 ft CMSS R6 2 J5A 10 Cable BNC to CMSS 793 two pin MIL 300 cm 10 ft o CMSS T 5 Reflective tape for optical and laser phase reference CMSS TMDT2K Digital thermometer kit e CMVA 3351 Power cord UL 110 V US e CMVA 3355 AC DC adapter universal for CMVA 6112 only does not include power cord e CMVA 3355 US AC DC adapter universal for CMVA 6112 only includes CMSS 3351 power cord CMVA 50230 4 Battery pack NIMH for CMVA 60 CMVA 10 and CMVA 40 9 CMVA 6112 CE Support module enhanced replaces CMVA 6111 support module o CMVA 6112 CE RU Support module enhanced Russian o CMVA 6112K CE Support module kit enhanced replaces CMVA 6111K CMVA 6120 03 02 SKF Microlog carrying case black nylon for use with CMVA 10 and CMVA 40 e CMVA 6121 SKF Microlog hard carrying case pelican gray for use with all models of SKF Microlog foam not cut to shape CMVA 6122 SKF Microlog carrying case clear plastic moisture protection for use with all models of SKF Microlog o CMVA 6130 SKF Microlog carrying case black cotton CMVA 6134 HD SKF Microlog hard shell carrying case with logo foam cut to shape o 10873706 230 V AC fast recharger for use with strobe light o 10873707 115 VAC fast recharger for use with str
66. exten sion cable 10 m 32 8 ft The CMAC 5044 straight extension cable is for use with the CMAC 5030K and CMAC 5030K Z2 laser tachometer kits This cable is 10 m 32 8 ft long and can be used in conjunction with the CMAC 5211 cable Specifications e Connectors Fischer type 103 seven pin female to Fischer type 103 seven pin male Length 10 m 32 8 ft straight Ordering information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5044 Tachometer straight extension cable 10 m 32 8 ft aKF CMAC 3715 Cable converter two pin MIL to BNC The CMAC 3715 adapter when combined with the CMAC 5209 accelerometer cable allows the SKF Microlog to connect to any male BNC connector This is useful for reading buffered outputs from protection systems switch boxes or process signal sources The adapter does not block DC signals so the user must be careful to avoid applying power to a buffered signal output Specifications e Connectors Two pin MIL to BNC e Length 8 5 cm 3 35 in Ordering information e CMAC 3715 Cable converter two pin MIL to BNC CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 37 CMAC 5023 Signal input straight cable The CMAC 5023 cable connects to the SKF Microlog CH1 or CH2 signal input connector at one end using the input connector sCH1 input pin and to any male B
67. g is safe for use in hazardous areas any other kind of stylus would require approval from the site s safety officer CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Ordering information e CMAC 5077 SD memory card 4 GB 86 Ordering information e CMAC 5251 Stylus IS aKF CMAC 5403 Audio headset hard hat compatible The CMAC 5403 audio headset connects to the SKF Microlog and allows users to listen to the audio output as an aid to machinery diagnostics such as with the Idler Sound Monitor The headphones are high quality and industrial grade Special earpiece cups reduce surrounding noise and are softly molded to provide comfort during extended wear The adjustable fabric head strap and neck band are designed for environments where a hard hat must be worn The audio connection includes a standard 3 5 mm 0 14 in jack plug Note To use the audio headset the CMAC 5078 audio headphone cable is required Ordering information e CMAC 5403 Audio headset hard hat compatible Optional availability CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 The CMAC 5403 audio headset is also available in the following two kits e CMAC 5410 ldler sound monitor accessory kit for SKF Microlog models CMXA 45 and CMXA 75 e CMAC 5411 Idler sound monitor accessory kit for SKF Microlog models CMXA 80 and CMXA 48 kit
68. g information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5090 Universal power supply includes four plug adapters aKF CMAC 5105 Battery The CMAC 5105 battery is the only ATEX certified battery pack to be used with the CMXA 51 IS unit Please read the Battery Documentation in the CD included in all applicable kits for important information on this item Specifications e Type NIMH e Capacity 1 800 mAh e Operating time 8 hours e Charge time 8 hours e Dimensions 66 x 55 x 21 mm 2 60 x 2 17 x 0 83 in Ordering information e CMAC 5105 Battery CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 73 CMAC 5110 Power supply The CMAC 5110 power adapter charges and powers the battery when connected to the CMXA 51 15 unit however it should only be used outside hazardous areas Note The CMAC 5110 power supply requires a country specific power cord Specifications e Voltage rating 8 6 V e Current rating 0 6 A e Cable length requirement 1 m 50 mm 3 3 ft 2 in CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5405 Strobe light power supply The CMAC 5405 universal power supply recharger supplies 115 or 230 V AC for use with the CMSS 6165 strobe light The power supply also comes with both US and Euro pean adapter cable
69. he other end Specifications e Connectors Fischer type 103 six pin to two pin MIL e Length 3 m 10 ft coiled Ordering information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5209 10 Accelerometer coiled cable 3 m 10 ft 33 CMAC 5211 BNC tachometer straight cable The CMAC 5211 cable connects to the power connector at one end using the power con nector s tachometer input pin and to any male BNC connector on the other end It can be used with any tachometer signal source that does not require the SKF Microlog to power it Note The CMSS 6195 Laser Reference Kit CMVA version kit or CMSS 6155 Optical Phase Reference Kit CMVA 60 version kit requires a CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5211 BNC tachometer cable to work with the SKF Microlog Specifications e Connectors Fischer type 103 seven pin trigger I P to BNC e Length 1 m 3 28 ft straight Ordering information e CMAC 5211 BNC tachometer straight cable 34 CMAC 5213 Laser tachometer kit straight cable 24 cm 9 5 in The CMAC 5213 laser tachometer cable connects the tachometer to the SKF Microlog The CMAC 5213 cable is a shorter cable than is sold in the CMAC 5030K laser tachometer kit This cable is only 24 cm 9 5 in long This shorter cable is preferred if the user uses the CMAC 5030K kits mount
70. ical e Current range 40A AC 60A DC range 0 2 to 40 A AC 60 A peak 0 4 to 60A DC 400A AC 600 A DC range 0 5 to 400 A AC 600 A peak 0 5 to 600A DC e Output signal 40A AC 60A DC range 10 mV A 400A AC 600A DC range 1 mV A on 600A range on 600A DC e Output termination 1 8 m 6 ft BNC aKF CMXA 45 CMXA 48 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMXA 45 75 Z2 CMXA 48 80 Z2 Overload 1 000A AC and 2 000 A DC continuous up to 1 kHz Rise and fall time 60Arange x 100 us from 10 to 90 Vout 600Arange lt 70 us from 10 to 90 Vou Insertion impedance 0 39 mO at 50 Hz 58 m0 at 1 000 Hz Load impedance gt 100 k0 100 pF maximum Frequency range DC to 10 kHz at 3 dB Working voltage 600 V RMS Common mode voltage 600 V RMS Influence of adjacent conductor lt 10 mA A at 50 Hz at 23 mm 0 905 in from the probe Influence of conductor in jaw opening 0 5 reading DC to 440 Hz Influence of temperature lt 300 ppm C or 0 3 10 C Influence of humidity 10 to 90 relative humidity at reference temperature lt 0 5 57 Electrical continued e Accuracy 40A AC 60 DC range 1 5 of reading 0 5 A 0 5 to 40A 1 5 of reading 40 to 60 A 400A AC 600 A DC range 1 5 of reading 1 A 0 5 to 100 A 2 0 of reading 100 to 400A 2 5 of reading 400 to 600 A DC e Phase shif
71. ile in use in a CMXA 51 IS the instrument It enables the operator to CMXA 51 IS hazardous area CMKA 70 46 hold onto the unit with one hand and still cMXA 70 46 press the keypad and fire buttons The hand CMXA75 strap fastens directly to the rubber boot or CMXA75 Es instrument It does not include a stylus VPN although it is equipped with a stylus holder Ordering information Ordering information e CMAC 5113 Shoulder strap leather hazardous areas e CMAC 5020 Hand strap 78 aKF CMAC 5072 Hand strap The hand strap is provided in all kits and is designed for easier and safer operations of the instrument It enables the operator to hold onto the unit with one hand and still press the keypad and fire buttons The hand strap fastens directly to the instrument Ordering information e CMAC 5072 Hand strap aKF CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5024 Instrument soft cover This protective carrying case is designed to provide additional protection to the SKF Microlog This instrument cover is to be used with the leather shoulder strap CMAC 5113 which is sold separately Ordering information e CMAC 5024 Instrument soft cover CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5071 Soft case The CMAC 5071 soft case includes a plastic protective sleeve an
72. ill eventually occur due to mechanical fatigue e g spring wear breakage etc then one or more of the following will result e Tool wear will significantly increase e The tool vibrates and leaves a bad surface finish e Fretting occurs in the spindle taper and tool holders e Unexpected tool breakage e Reduced tool life e Safety of the machine operator is at risk Early preventive actions can be taken to avoid unnecessary machine shut down and to avoid a number of other problems that cannot be defined e g excessive tool wear loss of tool life and tool breakage Accessories are available to extend the Spindle Assessment kit uti lization and to maximize the utilization of the Spindle Test module firmware Ordering information e CMAC 5121 Pull force gauge 2 5 to 20 0 kN base unit e CMAC 5122 Pull force gauge 10 0 to 75 0 kN base unit 91 SKF spindle assessment accessories continued CMAC 5123 through CMAC 5125 Pull force gauge taper rings The CMAC 5123 CMAC 5124 and CMAC 5125 taper rings are used with the CMAC 5121 or CMAC 5122 pull force gauge These different sized taper rings can be interchanged based on the size needed The different sizes of taper rings available are as follows e CMAC 5123 SK30 ISO MAS e CMAC 5124 SK40 ISO MAS e CMAC 5125 SK50 ISO MAS CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 These taper rings are used with
73. ing bracket to attach the tachometer directly to the SKF Microlog Specifications CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e Connectors Fischer type 103 seven pin to four pin socket e Length 24 cm 9 5 in straight Ordering information e CMAC 5213 Laser tachometer kit straight cable 24 cm 9 5 in aKF CMAC 5214 Laser tachometer kit straight cable 2 m 6 56 ft for CMAC 5030K The CMAC 5214 laser tachometer cable connects the tachometer to the SKF Microlog The CMAC 5214 cable which is also included in the CMAC 5030K and CMAC 5030K Z2 laser tachometer kits allows the user to place the tachometer on a stationary surface up to 2 m 6 56 ft away from the SKF Microlog Specifications CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e Connectors Fischer type 103 seven pin to four pin socket e Length 2 m 6 56 ft straight Ordering information e CMAC 5214 Laser tachometer kit straight cable 2 m 6 56 ft aKF CMAC 5036 CH1 signal input straight ex tension cable 5 m 16 4 ft The CMAC 5036 cable which is used for the CH1 signal input is a straight extension cable that is 5 m 16 4 ft long This cable can be used with single channel and triax sensors Specifications e Connectors Fischer type 103 six pin female to Fischer type 103 six pin male e Length 5 m 16 4 ft
74. itivity 5 100 mVg e Measurement range 50 g RMS e Frequency range 5 0 5 to 3 000 Hz 10 0 3 to 5 000 Hz 3 dB 0 2 to 10 000 Hz e Amplitude non linearity 1 full scale maximum e Resonance frequency mounted nominal 25 kHz e Transverse sensitivity lt 5 Electrical e Power requirements Voltage source 18 to 30 V DC Constant current diode 2 to 20 mA Do not apply power to this instrument without current limiting in the range of 20 mA maximum To do so will immediately destroy the integral ampli fier It is suggested that only SKF approved power units be utilized for pow ering this instrument 10 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e Electrical noise 0 0005 g RMS e Output impedance 100 Q e Bias output voltage 12 to 13 V DC e Discharge time constant 0 6 s e ase ground isolation signal power ground pin to case 10 MO Environmental e Temperature range 55 to 120 C 65 to 250 F e Vibration limit 1 000 g RMS e Shock limit 2 O00 g peak e Base strain sensitivity 0 001 g u strain at 250 u 0 e Thermal coefficient of sensitivity 0 05 C 0 03 F Physical e Dimensions See drawing e Weight 115 g 4 1 oz e Mounting Captive 1 4 28 mounting screw e Case material Aluminum alloy Sealing Welded glass to metal seal O rings hermetic Connections Coaxial radically mou
75. kit includes a triax accelerometer triax accelerometer cable stud adapter and three CMAC 9600 01 toolkit for 1 28 stud studs A calibration certificate traceable to NIST is also supplied with each instrument Optional Accessories e CMAC 9600 01 Toolkit for 1 4 28 stud e CMSS 908 MD Medium duty magnetic base aKF 11 CMSS 2111 Small footprint accelerometer with Integral cable CMXA 45 CMXA 45 75 Z2 CMXA 48 The CMSS 2111 is a small footprint accelerometer that includes an integrated 2 m 6 56 ft cable along with a magnetic mount CMSS 908 LD This acceler ometer is capable of working to a depth of 5 m 16 4 ft additional cable length required CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Specifications Dynamic e Sensitivity 41095 100 mVg e Measurement range 50 g e Frequency range 3 dB 0 5 to 10 000 Hz e Non linearity 1 e Resonance frequency 22 kHz e Transverse sensitivity lt 7 Electrical e Power supply Voltage source 18 to 28 V DC Constant current diode 2 to 20 mA Physical e Electrical noise e Dimensions hex x height 14 x 64 mm 0 55 x 2 52 in Broadband e Weight with cable 99 g 3 5 oz 1 Hz to 10 kHz 350 ug e Cable length 2 m 6 56 ft Spectral e Mounting Magnet 10 Hz 8 ug Hz e Case material Stainless steel 100 Hz 5 ug V Hz Cable type Polyurethane 1 kHz 4 ug Hz Sealing Molded e Output imp
76. lated rotational speed applica tions including very high speed monitoring a bracket for mounting the tachometer directly to the SKF Microlog using the camera mount located on the bottom of the SKF Along with the tachometer this kit includes Microlog The kit also includes a two meter cable to connect the tachometer to the SKF Microlog and a small tripod for a stationary mounting of the tachometer during the mea surement The key features of this laser tachometer kit include Tachometer is ATEX certified Operating frequency up to 250 000 r min Long optical range up to 2 m 6 56 ft Wide angle of operation up to 80 On target indicator standard Protection rating IP 67 Integral connector Stainless steel housing Threaded or plain housing options Reverse polarity and short circuit protected Specifications Material Stainless steel housing Color Silver Optical range 100 to 2 000 mm 0 33 to 6 56 ft Cable Fischer seven pin type 103 to four pin socket 2 m 6 56 ft Angle of incidence 80 Speed range 0 1 to 250 000 r min Power input 5 V DC at 30 mA typically Operating temperature 10 to 40 C 15 to 105 F IP rating IP 67 Housing types M20 threaded or plain body plus fixing slots Connections Integral connector Dimensions 70 x 20 mm 2 76 x 0 79 in ATEX certification BASO2ATEX3259X ExII 3 G EExnL IIC T6 Kit contents Compact laser tachometer CMAC 5215 Mounting bracket
77. latness 60mm 1 3 um 100 mm 2 0 um e Measuring pressure 5 to 10 N 3 7 to 7 4 ft Ib Ordering information e CMAC 5138 Depth micrometer CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 93 SKF spindle assessment accessories continued CMAC 5139 CMAC 5140 CMXA 45 Belt tension gauge CMXA 45 75 Z2 CMXA 48 The CMAC 5139 and CMAC 5140 belt tension gauges are used to measure belt tension By pressing the mechanical gauge on the belt it indicates the belt tension value It verifies the result together in the CMXA 51 IS Spindle Assessment kit and the Spindle Test module CMAC 5139 is used to measure belt tension between 15 and 70 kg between 30 and 150 Ibs CMAC 5140 is used to measure belt tension between 50 and 150 kg between 100 and 300 lbs CMXA 48 80 Z2 CMXA 70 44 CMXA 75 CMXA 80 CMAC 5139 Belt tension gauge CMAC 5140 Belt tension gauge Ordering information e CMAC 5139 Belt tension gauge 15 to 70 kg 30 to 150 Ibs e CMAC 5140 Belt tension gauge 50 to 150 kg 100 to 300 Ibs 94 aKF Accessories for obsolete products Model number CMAC 4300 CMAC 4321 CMAC 4400 CMAC 4628 CMAC 5004 CMAC 5017 CMAC 5022 CMAC 5152 CMAC 5153 CMAC 5211 CMAC 5401 K CMAC 5402 CMSS 2100 CMSS 2100 K CMSS 31476402 CE CMS 1707500 CE CMSS 376 CMSS 50077A CE CMSS 50080 CE CMSS 5
78. lerometer adhesive mounting base with Petro wax two cables carrying case certificate of conformance and calibration certificate e CMAC 5058 Modal hammer kit includes hammer BNC cable carrying case certificate of conformance and calibration certificate accelerometer not included aKF 53 CMAC 5059 Modal analysis hammer kit This calibrated modal hammer kit may be used for impulse testing of the dynamic behavior of mechanical structures by striking the object with the hammer and measuring the resulting response with an accelerom eter The hammer imparts a constant force over a broad frequency range which depends on the type of tip used The hammer has an integral constant current quartz force sensor mounted on the striking end of the hammer head The sensor converts the impact force into electrical signal for display and analysis It is designed with rigid quartz crystals and a built in microelec tronic unity gain amplifier Due to the laser welded construction of the sensor element operation is reliable in adverse environments The striking end of the hammer has a threaded hole for installa tion of a variety of impact tips that are included in the kit The tip transfers the impact force to the sensor and protects the sensor face from damage Tips of different stiffness allow the variation of the pulse width and correspondingly the frequency content of the force Modal analysis and modeling is also available by fixing th
79. lity reduce friction and power losses and extend lubricant life Mechatronics SKF fly by wire systems for aircraft and drive by wire systems for off road agricultural and forklift applications replace heavy grease or oil consuming mechanical and hydraulic systems Lubrication solutions From specialized lubricants to state of the art lubrication systems and lubrication management services lubrication solutions from SKF can help to reduce lubrication related downtime and lubricant consumption Actuation and motion control With a wide assortment of products from actu ators and ball screws to profile rail guides SKF can work with you to solve your most pressing linear system challenges aKF Accelerometers Triax accelerometer kit CMAC 4370 K 10 Small footprint accelerometer with integral cable CMSS 2111 12 High frequency accelerometer kit CMSS 2114 K 14 General purpose low profile side exit industrial accelerometer CMSS 2200 and CMSS 2200 MB ius ERROR AA AI ORE DER MEE SR 16 Intrinsically safe IS industrial accelerometer CMSS 2210 18 Small diameter accelerometer CMSS 732A 20 CSA approved general purpose industrial accelerometer CMSS 793 CA 22 ATEX approved intrinsically safe IS general purpose industrial accelerometer CMSS VOOEEE ae AA AD be OD NA SE 24
80. ncludes hammer three tips cable carrying case certificate of conformance and calibration certificate 55 CMAC 5084 Microphone with integral preamplifier kit The CMAC 5084 microphone kit contains an array microphone for general purpose use The constant current microphone enables acoustic type monitoring and is designed with a preamplifier A CMAC 5023 signal input cable Fischer six pin to BNC is includ ed to allow connection to the SKF Microlog The kit also includes a calibration certificate Specifications Dynamic e Frequency response 2 dB 20 to 10 000 Hz e Frequency response 2 to 5 dB 20 to 20 000 Hz e Sensitivity at 1 kHz 45 mV Pa e Inherent noise 1 3 octave at 250 kHz 15 dB e nherent noise A weighted 30 dB e Dynamic range 3 distortion limit gt 122 dB Electrical e Excitation voltage 18 to 30V DC e Constant current excitation 2 to 20 mA e Output bias voltage 5 5 to 14 V DC e Output impedance 150 Q Environmental e Temperature range operating 10 to 50 C 15 to 125 F Physical e Weight 18 5 g 0 66 oz e Size overall 12 7 x 66 2 mm 0 50 x 2 61 in Size head 7 x 28 mm 0 28 x 1 10 in Electrical connector output BNC jack e Housing material Stainless steel e Nominal microphone diameter 6 35 mm 0 25 in Kit contents CMAC 5023 cable e Microphone with preamplifier e CMAC 5023 Signal input cable e Calibration certificate 56
81. ndardize sensitivities within a few percent of nominal value Calibrated hammer 353B04 accelerometer CMAC 5056 only CMAC 5056 CMAC 5057 CMAC 5058 kits include Calibrated hammer Cable BNC to Fischer six pin for a sturdier cable CMAC 5088 may be used Red hammer tips two White hammer tip Black hammer tips two Steel tip Blue tip covers two Petro wax Screws threaded on both ends two Hammer extender Carrying case CMAC 5056 kit also includes 353B04 Accelerometer Magnetic accelerometer base CMAC 5061 Cable Fischer six pin to Microdot CMAC 5057 kit also includes 353B16 Accelerometer CMAC 5062 Cable Fischer six pin to Microdot Hammer extender 353B16 Magnetic Red hammer tip accelerometer accelerometer base CMAC 5057 only CMAC 5056 only White hammer tip Black hammer tip Steel tip 52 Blue tip cover Petro wax Screw threaded on both sides aKF CMAC 5061 cable CMAC 5056 only CMAC 5062 cable CMAC 5057 only BNC to Fischer cable Carrying case contents may vary Ordering information e CMAC 5056 Modal hammer kit for use on structures with a mass of 210 g 7 6 oz and above Includes hammer accelerometer magnetic mount adhesive mounting base with Petro wax two cables carrying case certificate of conformance and calibration certificate e CMAC 5057 Modal hammer kit for use on structures with a mass of 56 g 2 oz and above Includes hammer acce
82. nted Four pin MIL C 26482 B AP e Recommended magnetic base CMSS 908 MD Kit contents e Triax accelerometer e Anti rotation pin mounted on the bottom surface of the sensor the anti rotation pin can be carefully un threaded from the sensor so that it can be permanently mounted CMAC 5009 Triaxial accelerometer cable CMAC 4300 Stud adapter CMSS 2620 3 Studs three e Calibration certificate traceable to NIST aKF Dimensions Model 6524 1 4 28 mounting screw Mounting screw is detachable Location of anti rotation pin viewed from above 30 2 mm 1 19 in gt Axis 2 Triax accelerometer Common ground Pin D 53 8 mm 2 12 in 10 32 tapped hole for calibration typical two places AR Sig Pwr Sig Pwr Axis 1 ON Axis 3 PinA 1 Anti rotation pin is a 4 40 socket Sig Pwr Axis 2 head cap screw head diameter 4 65 Pin B mm 0 18 in maximum Axis 3 Mid 2 Sig Pwr ground return is isolated from case by gt 10 MO 3 Torque mounting screw T 15 Ib in b Axis arrowheads delineate sense and direction of positive acceleration for positive going voltage 24 1 mm 0 95 in KOK 25 4 mm CMAC 5009 triaxial accelerometer cable 1 00 in 7 Mounting surface CMAC 4300 stud CMSS 2620 3 stud adapter Optional accessories Ordering information e CMAC 4370 K Triax accelerometer kit Each
83. obe light o 96 aKF Product index Model number CMAC 3715 CMAC 4200 K SL CMAC 4370 K CMAC 5009 CMAC 5010 CMAC 5015 CMAC 5020 CMAC 5023 CMAC 5024 CMAC 5026 CMAC 5029 CMAC 5030K CMAC 5030K Z2 CMAC 5031 CMAC 5032 CMAC 5036 CMAC 5037 CMAC 5043 CMAC 5044 CMAC 5056 CMAC 5057 CMAC 5058 CMAC 5059 CMAC 5061 CMAC 5062 CMAC 5068 CMAC 5069 CMAC 5070 CMAC 5071 CMAC 5072 CMAC 5073 CMAC 5074 CMAC 5075 CMAC 5077 CMAC 5078 CMAC 5079 CMAC 5082 CMAC 5083 CMAC 5084 CMAC 5087 CMAC 5088 CMAC 5090 CMAC 5091 CMAC 5092 aKF Description Cable converter two pin MIL to BNC Infrared thermometer Triax accelerometer kit Triaxial accelerometer coiled cable Shoulder strap Rubber boot Hand strap Signal input straight cable Instrument soft cover Carrying case location for printer Carrying case hard shell Laser tachometer kit Laser tachometer kit ATEX certified Battery Power Trigger splitter straight cable CH1 signal input straight extension cable 5 m 16 4 ft CH1 signal input straight extension cable 10 m 32 8 ft Tachometer straight extension cable 5 m 16 4 ft Tachometer straight extension cable 10 m 32 8 ft Modal analysis hammer kit for structures 210 g 7 6 oz and above Modal analysis hammer kit for structures 56 g 2 oz and above Modal analysis hammer kit without accelerometer Modal analysis hammer kit High frequency acc
84. ompatible with SKF Microlog models CMXA 48 and CMXA 80 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 Compatible CMXA 51 IS SKF Microlog models CMXA 70 44 CMXA 75 CMXA 80 Example of compatibility legend Note The CMXA 45 75 72 designation in the legend refers to both CMXA 45 Z2 and CMXA 5 Z2 ATEX Zone 2 certified models The CMXA 48 80 Z2 designation in the legend refers to both CMXA 48 Z2 and CMXA 80 Z2 ATEX Zone 2 certified models aKF SKF Microlog models The accessories in this catalog are applicable to the following SKF Microlog models CMXA 44 SKF Microlog Analyzer MX series CMXA 45 SKF Microlog Advisor Pro CMXA 45 Z2 SKF Microlog Advisor Pro certified for use in ATEX Zone 2 hazardous areas CMXA 48 SKF Microlog Consultant CMXA 48 72 SKF Microlog Consultant certified for use in ATEX Zone 2 hazardous areas CMXA 51 IS SKF Microlog Analyzer certified for use in intrinsically safe IS areas CMXA 70 SKF Microlog Analyzer GX series CMXA 75 SKF Microlog Analyzer GX series CMXA 75 Z2 SKF Microlog Analyzer GK series certified for use in ATEX Zone 2 hazardous areas CMXA 80 SKF Microlog Analyzer AX series CMXA 80 22 SKF Microlog Analyzer AX series certified for use in ATEX Zone 2 hazardous areas Note For use of accessories in hazardous areas reference the product safety instructions Accessories listed as compatible with the CMXA 45 75 48 80 models may also be used with the
85. our pin to two pin MIL e Length 2 m 6 56 ft coiled Ordering information e CMAC 5115 ATEX certified accelerometer coiled cable 32 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 15 CMXA 70 44 CMXA 75 CMXA 80 CMAC 5209 CMXA 45 Accelerometer coiled cable 2m 6 56 ft CMXA 45 75 Z2 CMXA 48 The CMAC 5209 coiled cable connects to the CMxXA48 80 22 CH1 or CH2 input connector at one end and to an accelerometer at the other end The CMXA 51 IS accelerometer connection is a two pin MIL CMXA 70 44 connector CMXA 75 Specifications CMXA 80 e Connectors Fischer type 103 six pin to two pin MIL e Length 2 m 6 56 ft coiled Ordering information e CMAC 5209 Accelerometer coiled cable 2 m 6 56 ft aKF CMAC 5209 065 Accelerometer coiled cable with safety breakaway The CMAC 5209 0685 coiled accelerometer cable is similar to the CMAC 5209 cable but also includes a safety breakaway Specifications e Connectors Fischer type 103 six pin to two pin MIL e Length 2 m 6 56 ft coiled Ordering information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5209 065 Accelerometer coiled cable with safety breakaway aKF CMAC 5209 10 Accelerometer coiled cable 3 m 10 ft The CMAC 5209 10 coiled cable connects to the CH1 or CH2 input connector at one end and to an accelerometer at t
86. pport module to PC 120 cm 4 ft Cable SKF Microlog audio Cable CMVA 60 CMVA 10 CMVA 40 to BNC with power 150 cm 5 ft Adapter SKF Microlog to Microdot 10 32 Cable SKF Microlog to BNC with power 450 cm 15 ft Cable SKF Microlog to CMSS 6186 CMSS TMDT2 CE compliant Cable SKF Microlog to CMSS 793V Standard SKF Microlog connection cable Cable SKF Microlog to modem Cable SKF Microlog to BNC 3 without diode 1 5 m 5 ft Cable CMSS 793 to SKF Microlog IS CE compliant Cable CMSS 6135E adapter to CMSS 6165 strobe light Cable CMVA 65 video out Cable CMSS 50289 to CMSS 376 Charge amp SKF Microlog adapter Probe tip 11 43 cm 4 5 in stinger 1 4 28 mounting Phase adapter Adapter CMSS 6186 and accelerometer with CMSS 50236 cable Optical phase reference kit for use with CMVA 10 and CMVA 40 Optical phase reference kit for use with CMVA 55 CMVA 60 and CMVA 65 Printer adapter Strobe light cover Strobe light kit for SKF Microlog CMVA series Primary current clamp probe 60A 600A Audio headphones kit includes audio headphone and adapter cable CMVA 55 CMVA 60 CMVA 65 Laser phase reference kit 115 230 V for use with CMVA 60 CMVA 65 CMVA Series CMXA 70 CMXA 44 95 Accessories for obsolete products continued N E 0 o ty o oc az x Model number Description Ce Ce e CMSS 786M Twin sensor multi parameter acceleration SEE e CMSS 29305 Low frequency accelerom
87. r industries SKF Solution Factories make SKF knowledge and manufacturing expertise available locally to provide unique solutions and services to our customers Meeting the toughest challenges Our network of knowledge and experience along with our understanding of how our core technologies can be combined helps us create innovative solutions that meet the toughest of challenges We work closely with our customers throughout the asset life cycle helping them to profitably and responsibly grow their businesses Working for a sustainable future Since 2005 SKF has worked to reduce the negative environmental impact from our own operations and those of our suppliers Our continuing technology development introduced the SKF BeyondZero portfolio of products and services which improve efficiency and reduce energy losses as well as enable new technologies harnessing wind solar and ocean power This combined approach helps reduce the environmental impact both in our own operations and in our customers Working with SKF IT and logistics systems and application experts SKF Authorized Distributors deliver a valuable mix of product and application knowledge to customers worldwide Dur knowledge your success SKF Life Cycle Management is how we combine our technology platforms and advanced services and apply them at each stage of the asset life cycle to help our customers to be more successful sustainable and profitable
88. rence location on a rotating shaft and some point defined on the shaft s vibration waveform such as the high spot or heavy spot is commonly called the phase angle Phase angle is measured for four main reasons e Balancing to locate the proper position on an unbalanced rotor for adding a compensating weight e Startup and coast down response to define critical speeds and to assess system damping e Detecting changes in operating balance to indicate problems such as changing electrical properties fan build up and shaft cracks e Detecting shaft misalignment resonance and other machinery problems Methods for establishing a phase reference Phase angle measurement requires two inputs a reference pulse triggered once each revolution and a vibration signal The SKF Microlog triggers off a positive going or negative going V DC pulse depending on how it is configured in the Trigger Slope polarity setting or in Trigger Setup The once per revolution reference pulse required by the SKF Microlog is provided by a non contact optical sensing system that produces a TTL pulse 5 to OV DC when reflective tape or paint installed on the rotating shaft passes through the sensor s light beam up to a maximum distance of 0 9 m 3 ft The phase angle measuring process The optical phase reference sensor systems for the SKF Microlog sense machinery speed and output a T TL signal synchronous with machine speed This output signal is used by the SK
89. rget On Target indicator allows correct reflection path and accurate measurement e Manual sensitivity knob provides dynamic fine tuning of sensor response On Off or charge switch Power Battery condition indicator Class 3R visible laser and nose piece Accurate measurements from low contrast surfaces Normal operation in high ambient light environments External DC power or recharger port e Tripod mounting bushing 1 4 20 UNC Specifications e Laser Visible red laser diode 650 nm 3 mW peak power e Classification Class 3R laser product per IEC60825 1 e Beam diameter 4 x 7 mm 0 157 x 0 275 in typical at 2 m 6 56 ft e Laser diode life 8 O00 hours MTBF e Operating range Up to 19 8 m 65 ft depending on target e r min range 1 to 150 000 r min e Minimum trigger duration 10 us e Power requirement Internal rechargeable battery aKF CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS O CMXA 70 44 CMXA 75 CMXA 80 Charger 100 to 240 V AC 50 to 60 Hz with USA UK AUS and EURO adapter plugs Output signals TL positive inverting pulse O to 5 V TL negative non inverting pulse 5 to OV Output connector DIN 5 Indicators On target laser on Sensitivity adjust Single knob on top panel Modes Normal auto and charging Dimensions 137 41 x 59 69 x 54 36 mm 5 41 x 2 35 x 2 14 in Weight 300 g 10 6 oz excluding cable Mounting 1 4 20 UNC bushing tripo
90. s CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Ordering information e CMAC 5110 Power supply IS 74 Ordering information e CMAC 5405 Strobe light power supply includes US and European adapter cables aKF Miscellaneous accessorles Shoulder strap CMXA 45 CMXA 70 CMXA 75 CMAC 5010 77 Shoulder strap CMXA 48 CMXA 80 CMAC 5073 77 Shoulder strap leather hazardous areas CMAC 5113 78 Hand strap CMXA 45 CMXA 70 CMXA 70 Z2 CMXA 75 CMAC 5020 78 Hand strap CMXA 48 CMXA 80 CMAC 5072 79 Instrument soft cover CMXA 45 CMXA 70 CMXA 75 CMAC 5024 79 Soft case CMXA 48 CMXA 80 CMAC 5071 80 Carrying pouch leather hazardous areas CMAC 5111 80 Rubber boot CMAC 5015 81 Carrying case location for printer CMAC 5026 81 Carrying case hard shell CMXA 45 CMXA 70 CMXA 70 72 CMXA 75 CMAC 5029 82 Carrying case hard shell CMXA 48 CMXA 80 CMAC 5069 82 Carrying case hard shell CMAC 5118 83 Fischer and audio connector cover set CMAC 5075 83 SDIO and dock connector cover CMAC 5083
91. s a location for a portable printer The case includes foam cutouts for the SKF Microlog unit six accelerometers a power supply and spare battery The case also includes a pouch for the power cord and cables as well as an elastic strap with a clip fastener used for holding the manual docu mentation The black case is made of double skinned ABS material weighs 1 kg 2 2 Ib and has dimensions of 45 x 35 x17 cm 17 713 96 71D Ordering information e CMAC 5026 Carrying case location for printer CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 81 CMAC 5029 Carrying case hard shell The CMAC 5029 hard carrying case includes foam cutouts for the SKF Microlog acceler ometers and magnetic bases Ordering information e CMAC 5029 Carrying case hard shell 82 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5069 Carrying case hard shell The CMAC 5069 hard carrying case includes foam cutouts for the SKF Microlog acceler ometers and magnetic bases When opened the cover includes a pouch for storing cables Ordering information e CMAC 5069 Carrying case CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 aKF CMAC 5118 Carrying case hard shell The CMAC 5118 carrying case is utilized to transport and store the SKF Microlog and its
92. t 40A AC 60 DC range lt 3 10 to 20A 45 to 65 Hz lt 2 20to 100A lt 1 5 100 to 400A 400A AC 600 A DC range 3 10to 100A lt 1 5 100 to 400A e Noise 60Arange DCto1 kHz lt 8 mV or 0 8A PP DCto 5 kHz s12 mV or 1 2A PP 0 1 Hz to 5 kHz x 2 mV or 0 2 APP 600 Arange DEto 1 kis dmv or LAPP DCto 5 kHz lt 1 5 mVor 1 5 APP 0 1 Hz to 5 kHz lt 500 uV or 0 5 A PP e Auto off 10 minutes may be disabled at power up e Electrical certification EN 61010 2 32 Reference conditions 18 to 28 C 64 to 84 F 20 to 75 relative humidity external magnetic field 40 A m no DC component no external current carrying conductor test sample centered 1 MO lt 100 pF load zero adjustment prior to measurement DC only DC to 65 Hz battery voltage 9 V 0 1 V 58 Environmental e Case protection IP 30 per IEC 529 e Operating temperature range 10 to 55 C 15 to 130 F e Storage temperature range 40 to 70 C 40 to 175 F e Operating relative humidity 10 to 35 C 50 to 95 F 90 5 relative humidity without condensation 40 to 55 C 105 to 130 F 70 5 relative humidity without condensation e Altitude Operating O to 2 000 meters 0 to 6 500 ft Non operating 0 to 12 000 meters 0 to 39 000 ft Mechanical e Zero adjustment Automatic zero e Battery 9 V alkaline e Low battery indication Green LED when
93. t locations Stylus IS Audio headset hard hat compatible Strobe light input straight cable CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 15 CMXA 70 44 CMXA 75 CMXA 80 Page 44 89 41 13 74 80 78 32 41 42 83 91 91 92 92 92 92 92 92 pa 92 92 92 92 92 22 93 93 94 94 89 90 90 42 bi 3 33 2 34 34 35 8 86 8 43 aKF Product index continued Model number CMAC 5405 CMAC 5406 CMAC 5410 CMAC 5411 CMAC 6139 CMCP 850 01 CMCP 850 02 CMCP 850 03 CMSS 2111 CMSS 2114 K CMSS 2200 CMSS 2200 M8 CMSS 2210 LMS56155AK U LE CMSS 6156 CMSS 6165K AX CMSS 6195AX K CMSS 32A CMSS 793 CA CMSS 793 EE CMSS 908 MD aKF Description Strobe light power supply Strobe light output straight cable Idler Sound Monitor accessory kit Idler Sound Monitor accessory kit Screen protector SKF Microlog Analyzer field balancing accessory kit with optical sensor SKF Microlog Analyzer field balancing accessory kit with laser sensor SKF Microlog Analyzer field balancing accessory kit with laser sensor Small footprint accelerometer with integral cable High frequency accelerometer kit General purpose low profile side exit industrial accelerometer General purpose low profile side exit industrial accelerometer with M8 studs Intrinsically safe IS industrial accelerometer Optical phase reference kit Optical phase refer
94. t m CMSS 6155XK U CE Optical phase reference kit e CMSS 6165K AX Strobe light kit o CMSS 6195AX K Smart laser sensor tachometer o aKF 29 CMAC 5009 Triaxial accelerometer coiled cable The CMAC 5009 coiled cable connects to the SKF Microlog CH1 input connector at one end and to a triaxial accelerometer at the other end The cable is recommended for use with the CMAC 43 0 K triax accelerom eter kit Specifications e Connectors Fischer type 103 six pin CH1 I P to a four pin socket e Length 2 m 6 56 ft coiled Ordering information e CMAC 5009 Triaxial accelerometer coiled cable 30 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5061 High frequency accelerometer straight cable The CMAC 5061 accelerometer cable is used with the CMSS 732A accelerometer and with the CMAC 5056 modal analysis hammer kit Specifications e Connectors Fischer type 103 six pin to a 10 32 Microdot connector e Length 1 5 m 5 ft straight Ordering information CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 e CMAC 5061 High frequency accelerometer straight cable aKF CMAC 5062 High freguency accelerometer straight cable The CMAC 5002 high freguency accelerom eter cable is used with the 352A60 high fre guency accelerometer in the CMSS 2114 K kit and in the CMAC 5057 modal analysis hammer kit Specific
95. ter plate ok Idler sound monitor accessories continued CMAC 5093 Signal input straight cable microphone cable The CMAC 5093 cable has a BNC connector on one end to connect to the CMAC 5091 microphone and a Fischer connector on the other end to connect to the SKF Microlog Specifications e Connectors Fischer type 103 six pin to BNC e Length 51 cm 20 in coiled CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 CMAC 5141 Parabolic reflector The CMAC 5141 parabolic reflector is an impact resistant case that holds the CMAC 5091 microphone The parabolic reflector focuses sounds to the microphone and protects the microphone from damage The parabolic reflector can either be held in the hand or attached to the SKF Microlog via the optional CMAC 5142 adapter plate for models CMXA 45 and CMXA 75 only When used with the high frequency CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 microphone faulty idlers can be detected from up to 3 m 10 ft away On windy days an optional wind jammer CMAC 5143 can be fit over the parabolic reflector to reduce wind noise Ordering information e CMAC 5093 Signal input straight cable microphone cable Optional availability The CMAC 5093 cable is also available in the following two kits e CMAC 5410 Idler sound monitor accessory kit for SKF Microlog mo
96. the corresponding ISO and MAS adapters CMAC 5126 through CMAC 5130 Accessories are avail able to extend the Spindle Assessment kit utilization and to maximize the utilization of the Spindle Test module firmware CMAC 5126 through CMAC 5136 Pull force gauge adapters These adapters are used with the CMAC 5121 or CMAC 5122 pull force gauge These different sized adapters can be inter changed based on the size needed Refer to the ordering information for the different sizes of adapters that are available The ISO and MAS adapters CMAC 5126 through CMAC 5130 are used with the cor responding taper rings CMAC 5123 CMAC 5124 or CMAC 5125 Accessories are CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 available to extend the Spindle Assessment kit utilization and to max imize the utilization of the Spindle Test module firmware CMAC 5123 SK30 taper ring CMAC 5124 SK40 taper ring Ordering information e CMAC 5123 Pull force gauge taper ring SK30 e CMAC 5124 Pull force gauge taper ring SK40 e CMAC 5125 Pull force gauge taper ring SK50 92 CMAC 5125 SK50 taper ring CMAC 5129 SK30 MAS adapter CMAC 5126 SK30 ISO adapter Ordering information CMAC 5126 Pull force gauge adapter SK30 ISO CMAC 5127 Pull force gauge adapter SK40 ISO CMAC 5128 Pull force gauge adapter SK50 CMAC 5129 Pull force gauge adapter 5K30 MA
97. tronic unity gain amplifier Due to the laser welded construction of the sensor element operation is reliable in adverse environments The striking end of the hammer has a threaded hole for installa tion of a variety of impact tips that are included in the kit The tip transfers the impact force to the sensor and protects the sensor face from damage Tips of different stiffness allow the variation of the pulse width and correspondingly the frequency content of the force Modal analysis and modeling is also available by fixing the acceler ometer at one location impacting the structure at one point and then moving the accelerometer to other points of interest When used with the FRF module the following modal parameters can be calcu lated and displayed e Apparent mass accelerance e mpedance Mobility e Stiffness Compliance 50 CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 Specifications CMAC 5056 Accelerometer 353B04 Dynamic e Sensitivity 5 1 02 mV m s 10 mVg e Measurement range 4 905 m s peak 500 g peak e Frequency range 5 1 to 7 000 Hz 10 0 7 to 11 000 Hz 3 dB 0 35 to 20 000 Hz e Resonant frequency gt 38 kHz e Broadband resolution 1 to 10 000 Hz 0 03 m s RMS 0 003 g RMS e Non linearity x 1 e Transverse sensitivity lt 5 Electrical e Excitation voltage 18 to 30V DC e Constant current excitation
98. ture 10 to 70 C 15 to 160 F Dimensions Threaded tube M16 x 1 5 mm length x 4 mm diameter 2 9 in length x 0 625 in diameter supplied with two M16 jam nuts and mounting bracket Kit contents CMSS 6155W U CE Self powered sensor CMSS 6155W Interface module CMAC 5211 BNC tachometer input cable CMSS T 5 Reflective tape Mounting bracket with two M16 jam nuts Universal recharger power supply with USA UK AUS and EURO adapter plugs User manual aKF CMSS 6155W interface module CMSS 6155W U CE self powered sensor Universal recharger power supply with adapters 61 Mounting bracket and jam nuts CMSS T 5 reflective CMAC 5211 BNC tachometer input cable tape Optional accessories CMSS 50401 extension cable CMSS 6156 magnetic holder Ordering information e CMSS 6155XK U CE Optical phase reference kit includes a self powered sensor BNC tachometer input cable and user manual Optional accessories e CMSS 50401 7 5 mm 25 ft CMSS 6155W Interface module to optical sensor extension cable e CMSS 6156 Optical phase reference magnetic holder with movable arm and remote optical sensor attachment hardware e CMSS T 5 Reflective tape for use with remote optical sensor 1 5 m 5 ft roll x 12 7 mm 0 5 in wide 62 aKF CMSS 6156 Optical phase reference magnetic holder CMXA 45 CMXA 45 75 Z2 CMXA 48 The CMSS 6156 optical phase reference holder with magnetic base is designe
99. wind jammer stretches over the CMAC 5141 parabolic reflector until snug Ordering information e CMAC 5143 Wind jammer Optional availability CMXA 45 CMXA 45 75 Z2 CMXA 48 CMXA 48 80 Z2 CMXA 51 IS CMXA 70 44 CMXA 75 CMXA 80 The CMAC 5143 wind jammer is also available in the following two kits e CMAC 5410 ldler sound monitor accessory kit for SKF Microlog models CMXA 45 and CMXA 75 e CMAC 5411 ldler sound monitor accessory kit for SKF Microlog models CMXA 80 and CMXA 48 kit does not contain CMAC 5142 adapter plate aKF SKF spindle assessment accessories CMAC 5121 CMAC 5122 Pull force gauges Pull force gauges are compact measuring devices used to check the force of the tool being pulled into the spindle taper The specified pull force is very important for the quality of machining Using the pull force gauge in preventive maintenance schedules will allow you to notice a reduction of the pull force and prevent problems before they occur The pull force gauge minimizes the down times for your machines Two different gauges are available e CMAC 5121 Measures pull force from 2 5 to 20 0 kN e CMAC 5122 Measures pull force from 10 0 to 75 0 kN Conventional gauges measure in accordance to the nominal compo nent dimension The manufacturing related tolerance range of the components could cause a false measuring result CMAC 5121 and CMAC 5122 offer the possibility to take these tolerances into consid
100. x M1 Exia 1 T 55 to 115 C 65 to 240 F e Group Il Two pin connector BASO2ATEX1057X and IECEx BAS 08 0013X mg MIL C 5015 ExII 16D T135 C 275 F Ex ia IICT4 ExiaD 2071135 C 275 F Ta 55 to 115 C 65 to 240 F ExII 16D T85 C 185 F Ex ia IICT6 ExiaD 20 T85 C 185 F T 55 to 65 C 65 to 150 F e 500V isolation Units will pass a 500 V isolation test e Barrier 1 x MTL7728 BASO1ATEX7217 or S N S00000 P amp F Z728 BASO1ATEX7005 or any other barrier that conforms to note 5 of ATX027 22 2 WIN LAAT 1 4 28 mounting hole Warning The Ci and Li were previously lower The installer must take this apparatus account of the increase in internal capacitance and inductance present on 25 0 mm 1 00 in Ordering information e CMSS 2210 Intrinsically safe IS industrial accelerometer Optional accessories e CMSS 908 MD Medium duty magnetic base aKF 19 CMSS 732A Small diameter accelerometer The CMSS 732A is an accelerometer with a 10 x 32 mounting stud Features e Wide dynamic range e Compact construction to fit in tight spaces Wide frequency range Small size lightweight Hermetic seal Designed for stud mounting Optional magnetic base mounting Specifications Dynamic e Sensitivity 10 mV g e Sensitivity precision 5 at 25 C 75 F e Measurement range 500 g peak e Frequency range
Download Pdf Manuals
Related Search
Related Contents
KOHLER K-705769-SHP Installation Guide Manuel BM8 Lithium - Instrumentation GDD GYMlive 1/2012 - Schweizerischer Turnverband Samsung HMX-F800SP Manuel de l'utilisateur Miele DA 6690 D Obsidian Black 36" Puristic Specification Sheet South Shore Furniture 3560A3 Instructions / Assembly Copyright © All rights reserved.