kullanim kilavuzu (user manuel) en81
Contents
1. CERTIFICATE OF COMPLIANCE Nome of the Manufocturer Argeten Elektronik ve Seslendirme San Ti lbeahim Aynan Oreticinin Ad Address of the Manufacturer A Yesevi Mah Biberik Cod Kristal Sok No 19 5 Burak Apt reticinin Adres Suttanbeyli ISTANBUL T RK YE Description of the Product PCB Lift Control Card for Electric and Hydraulic Lift r n Elektrik ve Hidrolik Asans r Kumanda Karty PCB Description of the Product HEYTECH HT 53 Type r n Tip Tan r Applicable EU Directive s 9 5 16 EC Litt Directive Annex Uygulonabile AT Applicable Standards i EN 81 1 2 Uygulonabilr Stondor lar inspection Ploce Alt n ehir Moh Kumru Cad Ceylan Sok No 65 A mraniye nceleme Yeni STANBUL T RK YE This certillcate does not regards 2004 100 1C tiectroemog etic Compatibility Orective Su seria 2004 108 AT Elektromanyetik Uyumiuluk Direktifi 3e light de i The litt contro cord ls ot subjected to Me Ioborot ory tests according to annes 6 of EN 81 1 2 A3 Tonumlanan Asans r PCB Controli Kari EN 81 1 2 A3 EV F 4 yo g re laboratuar testierine tGt de ikir Me PCR controt card complets to the tuectioeo requirement referred to in this Certificate taking into account additional remarts mentioned cbove Asomedr PCS Konto Kork yukanda berilen o kkamalar diktate ol norak bu belge de ad ge en ortlar fonksiyonel eriterer o nundan Uygundur Certif
2. heytech HT 53 ASANS R KUMANDA KARTI LIFT CONTROL CARD CE heytech KULLANIM KILAVUZU USER MANUEL EN81 1 2 A3 CE 103 3784 SAFETY NOTES HEYTECH HT 53 Control card comply with EN81 1 2 A3 standard is an integrated and electronic control card that has been designed for drive type hydraulic and roped Lifts Users can make the programs of control card according to control and Lift system utilised by them by means of the keyboard on the LCD screen The system can make level renovation and early door opening with built in door bridging relays There are built in door relays for double automatic doors There is built in phase control circuit For the Lift system to be electrically complies with EN81 1 2 A3 standards the electrical connections of the control card and control panel should be appropriate Check certainly whether there is earth connection or not Connect especially control panel motor body all safety device cabin and its suspension to the earth line Do not remove the glass housing without cutting the power of the control card Dust dirt oil and rusting arising from the long time working may prevent the good operation of the safety devices During periodic maintenances necessary cleaning should be performed If your system has A3 compatible speed regulator do not cancel its electrical and mechanical connection If
3. Deceleration coefficient is set by this parameter It can be in factor defaults 56 UCM Test UCM test can be made by this parameter automatically e Down direction e Up direction a7 ractory Pos Wait by passing ENTER button until OKEY appears on the screen The system will be returned to factory settings 19 MAGNETIC SWITCH and MAGNETS INSTALLATION HT 53 System can be operated with 4 different position detection methods These counter methods are Standard MO counter system It is used in double speed lift system whose deceleration distance is smaller than the half of the distance between the floors Standard M1 counter system It is used in double speed lift system whose deceleration distance is smaller than the half of the distance between the floors ML1 ML2 counter system It is used in VVVF and Hydraulic lifts system in which door bridging will be made Encoder counter system lt is used in VVVF and Hydraulic lifts system in which door bridging will be made 141 142 will not be arranged Magnetic switches and magnets that will be used by drive type are shown in the following table Drive Type Cabin Position Door front Magnetic switch Magnet Detection opening Levelling Double Standard MO Unusable M1 MO Bistable Round magnet speed counter 142 Bistable Standard M1 counter VVVF ML1 ML2 counter ML1 ML2 Monostable Hydraulic Encoder counter Can be used 141 142 Monostable gaem ane
4. At the end the time that has been set by this parameter if the lift door does not closed the control panel will go out of the service if required this function can be cancelled t the time to pass to door open error 11 Door Maximum Time e 15 250 Seconds AUG to Rec You can set the waiting time with this parameter before going to Park Station e 0 250 Seconds 13 Park Station The station where the lift will wait at the end the set time is set with this parameter 20 14 Fire Station Fire station is set with parameter When the fire entry YAN is active lift goes directly to the defined floor and waits with open doors With cutting the fire signal the lift returns to normal operation e CANCEL Fire station is not defined in the system e 1 20 Fire is defined to 1 201 station in the system 15 Direction Arrow Flash When the lift is active you can set the flashing of the direction arrow by this parameter e CANCEL Direction arrows lights in the direction of movement e ACTIVE Direction arrows flash in the direction of movement 16 Ch angel The card password is changed or determined with this parameter e if it is 1 0 0 0 0 the password become active 1 17 Password Cancel You can cancel the password with this parameter if itis 0 0 0 O the password is cancelled 12 18 Maintenance Done m Maintenance time is zeroed with this parameter
5. Up learning D 01 0 015 6542 In 1 Up learning the lift goes at low speed on the top floor by slowing on the lower floor of the top floor The low speed is the underlined digit on the left It should not exceed 0 15 If it exceeds this value reduce the low speed from the speed control 4 Down learning D 01 In 1 Down learning the lift goes at high speed until 817 stopped and it 0 15 65842 stops when see ML1 and ML2 magnet Up learning The lift will start learning in upward When Up learning it will slow down D 01 0 15 65842 and speed up at each floor and then it will save all well information into the memory Down learning D 01 0 15 65842 The lift will go to the bottom floor and stop Well revision will appear on the screen The well copying operation has been completed You can make your other settings L 52 Floor descent correction 20 000 This menu is used to make down direction settings If the lift is up direction digit is entered if it is down direction digit is entered Levelling is made Each number is 1 mm Correction can be made at maximum 125 mm 4 52 Floor ascent correction 01 000 This menu is used to make down direction settings If the lift is up direction digit is entered if it is down direction digit is entered Levelling is made Each number is 1 mm Correction can be made at maximum 125 mm Note
6. Serial code ABCDEFG CARD MENU 00 First Setup If the lift starts to operation newly setup is made by activating this parameter Cancel 1 Lif LL E You can set your lift drive type by this VVF SPEED parameter SINGLE SPEED LIFT For single speed roped lifts this setting should be selected DOUBLE SPEED LIFT For double speed lifts this setting should be selected ROPED VVVF stepped geared asynchronous machine and gearless synchronous machine HYDRAULIC For hydraulic lifts this setting should be selected _ 02 You can set your lift control type with this parameter Simple Control e SIMPLE CONTROL Cabin and floor buttons are connected in parallel It only takes one record e UNIVERSAL Cabin and floor buttons are connected in parallel Record memory is kept e COLLECTION IN LANDING Cabin and floor button are connected separately Cabin records are collected in both directions Floor calls are collected while the cabin is moving downward e DOUBLE DIRECTION COLLECTION Cabin record and the Up and Down buttons of the floors are connected separately Cabin records and floor calls are collected in accordance with the movement direction e DUPLEX SPECIAL If station number is more than 11 in duplex lifts the double button is used for collection You can set the number of station of your lift wit
7. signal 140 is set with this parameter e 8 30 Seconds 07 Lock Waiting Time 008 Second 10 Maii During the collection you can set the waiting Ec Time time in the station with this parameter before going to the records e 3 15 Seconds According to EN81 1 and EN81 2 standards in manual door lifts when the cabin reaches the floor it should wait at least 2 second before starting the operation again In lifts with simple control without collection this parameter should be kept same with the CABIN LAMP time and set to at least 2 seconds 09 High Speed Time During the movement of the lift from one floor to another the permitted maximum course time is 015 Second set by means of this parameter If this time is exceeded the system will automatically stop the movement of the cabin and will be blocked e 5 120 Seconds According to EN 81 1 2 standards the time of motor operation timeout is set in a way that it is not exceeding the smaller of the following times a 45 seconds b The longest course distance 10 seconds c If the longest course distance is less than 10 seconds the timeout time should be at least 20 seconds When the lift reach the target floor the LO Low maximum low speed time of the lift until it show the stopper on the floor is set by means of this parameter If this time is exceeded the card will automatically stop the movement of the cabin e 5 60 Seconds
8. 100 and ML2 100 terminals Long magnets strips that will be used for these magnetic switches are 30cm Number of magnets strips are given by number of station Number of magnets strips of 30cm Station number Installation oflong magnets strips Bring the cabin to the bottom floor Cabin threshold should be at level of the bottom station In this case place the strips against the magnetic switches in 1 2 cm distance so that the midpoints of the magnetic strips face with the midpoint of the magnet strip Fix it with adhesive of magnet or screw only applying of 30cm magnets is sufficient Apply this procedure for other stations 30 cm strip magnet Monostable 2 mme Monostable 1 gt Cabin ca Floor level 24 Encoder Connection 1 DRIVER HEYTECH CARD A B ENA ENB L Encoder connection 2 ENCODER HEYTECH CARD VCC VDD A EN IF ENCODER INFORMATION IS GIVEN FROM THE DRIVER IF ENCODER INFORMATION IS GIVEN FROM THE DRIVER 23 ENCODER FAST SYSTEM SETUP i 03 Station number 003 Enter the lift station number y 44 Counter type Encoder counter Enter the counter type as encoder counter L 48 Encoder Dividing 026 Enter the encoder dividing number according to the following calculation Motor cycle X Encoder pals number 60 Lift speed NOTE the speed is entered as 1000 times Ex motor cycle
9. 15 To activate level renewal this parameter is used for roped VVVF and Hydraulic Lifts Floor setting from inside of the cabin cannot be made without activate this parameter 36 Door Open Levelling e CANCEL Level renewal is cancelled e ACTIVE Level renewal is active 37 Lowest Station This parameter is used only for group Work If there is station difference among the lifts in group the first station setting for the different lift is made with this parameter While this setting is made station number of the lifts in the group should be set same from menu For example in a duplex system with 10 station if A lift does not give service for the lowest floor and B lift do this Both lifts are set to 10 station and the first station setting for A lift should be set as 2 The opening distance of automatic door in millimetres from the floor is set with this parameter It is used only if the early door opening is active e 040 150 mm 38 Early Opening Way 39 Call Transfer Call transfer is set with this parameter 40 Display Output HT 52 control card and HT SERIAL card display output settings are made with this parameter e 7 SEGMENT OUTPUT Normal e GRAY CODE OUTPU Gray code output e BINARY CODE OUTPUT Binary code output LLLL LD This parameter determine maximum record number that can be given by cabin inside After
10. 920 X encoder pals 1024 942080 60 lift speed 600 Result 26 168 26 encoder dividing is entered as 26 L 00 First Setup Active Activate the first installation parameter Warning Cancel the first setup when well reading and floor adjustments finished Exit the menu pressing ESC button L Make Well reading D 01 0 00 65842 This messaoe recalls that you should to make well reading For making well reading take the lift from the well to the revision position Revision from well D 01 0 00 65000 Before starting the well reading observe the changing of the underlined digits on the left by moving up and down These digits are information of speed and encoder If there is no changing on the digits check your encoder or its connection L Revision from well D 01 0 00 65842 Ensure that 817 818 switches are active leds lights Warning When making well reading do not make bridging for 817 and 818 4 Revision from well D 01 0 00 65842 Press ESC for 3 seconds on the control card The lift will move downward NOW ENJOY HEYTECH WELL READING SYSTEM READING BY SITTING BACK 1 26 Encoder reset D 01 0 00 65842 This message will appear on the LCD screen The lift will go at high speed until it sees 817 interrupter After seeing 817 interrupter it will at low speed up to ML magnets and stop at floor level L
11. Vem depending on Band magnet option INSTALLATION FOR M1 and MO COUNTER SYSTEM In M1 and MO counter systems cabin movement and floor information are detected with 2 types magnetic switches 1 Floor counter and Retarder Magnetic Switch M1 Bistable 2 Magnetic Switch that provides stopping on the floor 142 Bistable Bistable magnetic switches and round magnets are used in this counter system MO and M1 switch is used as floor counter and retarder 142 switch operates as the element that provides stopping on the floor 1 Make the magnet arrangement as described in the connection diagrams user manual 2 Connect switches ends respectively to M1 100 24v and 142 100 24v terminals Level renewal cannot be made in this counter system 20 INSTALLATION OF OBLIGATORY INTERRUPTORS TO BE USED IN ALL COUNTER Bistable 818 ume i Up obligatory Deceleration way i Rue top floor level CABIN Down obligatory Deceleration way Bistable 817 Bee Se ee a Re Bottom floor level CABIN 817 lowest floor and 818 top floor are obligatory retarder bistable switches Whatever the counter system these switches should be used in all lifts The gap between magnetic switch and rail should be maximum 3cm 21 INSTALLATION FOR ML1 ML2 COUNTER SYSTEM In ML1 ML2 counter systems cabin movement and floor information are detected with 2 type magne
12. WHEN WELL COPYING IS COMLETED CANCEL THE FIRST SETUP OPTION FROM THE MENU 27 To make the floor correction from within the cabin ACTIVATE THE LEVEL RENEWAL FROM 36 PARAMETER ACTIVATE 00 PARAMETER HOLD DOWN THE FLOOR BUTTON WHERE YOU ARE IN THE CABIN PRESS DOOR OPENING BUTTON FOR 5 TIMES THE CABIN LIGHT WILL TURN OFF WHEN THE CABIN LIGHT TURN OFF PREES THE DOOR OPENING BUTTON AND HOLD DOWN IT e RELEASE THE FLOOR BUTTON ONLY HOLD DOWN THE DOOR OPENING BUTTON MAKE DOWN CORRECTION WITH LOWER FLOOR BUTTON AND MAKE UPWARD LEVELLING WITH HIGHER FLOOR BUTTON WHEN REACHE FLOOR LEVEL RELEASE THE BUTTON YOUR FLOOR INFORMATION HAS BEEN TAKEN INTO MEMORY ERRORS AND SOLUTIONS UCM ERROR There may be an error in your magnet arrangement There may be an error in your A3 connections SOLUTION Press ESC button for 30 seconds and save your lift from USC error Then check the connections magnets and tubes MAKE WELL READING SOLUTION If you see this message again after well reading check station number Check ML magnets and 817 818 TAKE TO THE APPROPRIATE POSITION SOLUTION Check if 817 or 818 is deactivated NO ENCODER PALS SOLUTION Check Encoder connections REVERSE DIRECTION MOVEMENT SOLUTION Change ML1 and ML2 positions ML SHORT CIRCUIT SOLUTION Check ML1 and ML2 connections FOUR YOUR TROUBLES YOU CAN GET LIVE SUPPORT FROM OUR 7 24 INTERNET SITE 28
13. 4 Overload Signal Input 805 Full Load Signal Input VAT Vatman Signal Input K20 Door Opening Button Photocell Signal Input DTS Door Closing Button Signal Input GO Gray amp Binary Code Outputs set the menu G1 Gray amp Binary Code Outputs set the menu G2 Gray amp Binary Code Outputs set the menu G3 Gray amp Binary Code Outputs set the menu G4 Gray amp Binary Code Outputs set the menu HT 53 Symbols of the Terminal Card X1 X20 Outer Button Call Inputs 869P Revision Key Hand Terminal 869K Revision Key Hand Terminal 500 Revision Down Signal Hand Terminal 501 Revision Down Signal Hand Terminal 817 Down limit Mechanical Swich Input 818 Up limit Mechanical Swich input MO Magnetic Bistable Switch Input M1 Magnetic Bistable Switch Input 141 Magnetic Switch Input used by Lift Drive Type 142 Magnetic Switch Input used by Lift Drive Type ML1 Door Zone Magnetic Swich input for VVVF and Hydraulic Systems ML2 Door Zone Magnetic Swich input for VVVF and Hydraulic Systems 869 Revision Key Well YAN Fire Active Signal Input 24v dc DEP Earthquake Active Signal Input 24v dc RGA Regulator Contact Active Signal Input It should be came a 24v dc from the contact to this input S1A Serial Communication Output A Channel Serial Communication Output B Channel Duplex Communication Output A Channel Duplex Communication Outp
14. As long as your card works the set value of this parameter will be reduced by 1 every day For example this parameter which is set to 45 days shows 15 values after 30 days and shows 0 values at the end of 45 days In case of this parameter takes 0 value the movement style of the lift is set by MAINTENANCE TIME EXPIRATION parameter Day e 45 250 days 19 Maintenance Time 20 Error List With this parameter the last 20 eror are monitored with station names by starting from the last error until the first error After the first error Delete Errors option appears All errors can be deleted by pressing ENTER Dini To change the station number come to the station you want to change by utilising UP DOWN buttons while the station digit flashes Then press come to the digital value pressing RIGHT button and enter the value that should be written If you want to make a setting for another station also come on the station you want to change again pressing LEFT button and repeat the same process At the end of the process exit the menu by ESC button Indicator type Outputs that can be selected 7 segment 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 indicator 13 14 15 16 A b C d F H J L n o P With this parameter the floor on which the automatic a and b doors will be opened is set To change the station number come to the station you want to change by utilising UP DOWN button while
15. arameter e 0000 2000 Milliseconds EU 46 Photocell Time By this parameter the door closing time is determined with the signal coming from photocell after automatic door has closed This parameter activates or deactivates the passing of the contactor card to the contactor feedback error If it is cancelled the control card does not detect contactor bonding e CANCEL KRC is cancelled e ACTIVE KRC is active 17 48 Encoder This parameter is entered by making a calculation according to lift speed encoder pals number and motor cycle EXAMPLE The value that is entered 1ms 1500 cycle motor 1024 pals encoder is 26 If the encoder is connected in regulator 1 is entered for 1024 pals encoder e ENCODER DIVIDER CALCULATION Motor cycle x encoder pals number 60 lift speed EXAMPLE 1000 RESULT EXAMPLE Motor cycle 160 X encoder pals 2048 327 680 60 5 461 lift speed 1000 5 461 5 is entered _ lt _ By this parameter you can set the automatic A D A utomaue door that should be open or closed during the oor park OU The control card will kept the last position in its memory even if the mains power is interrupted But in some special cases a position reset may be wanted when the power is provided for the lift again In this case the will go to the lowest floor until seeing 817 interrupter When it reaches the bottom floor the floor c
16. h this parameter up to 20 stations ELLM a 04 Number Baser You can set the number of basement with this parameter Elevator control type landing in the collection becomes available floor outlet collection under the number entered in the basemeni floor Type of sand used in the 01 collection of the landing outside Qa oor IE You can set the on off signal type for automatic Swinging Door doors with this parameter e SWINGING DOOR used only for non automatic door lifts e D AUTO LIMITED used only for lifts which have automatic limited cabin door e D AUTO UNLIMITED Used for lifts which have automatic unlimited cabin doors e FULL AUTO LIMITED used for lifts which have full automatic limited door e FULL AUTO UNLIMUTED used for lifts which have full automatic unlimited door According to EN 81 1 2 standards the automatic door should remain immobile in revision and recall positions MERE Litus e 5 20 Seconds this is the delay time of cabin 006 Second amp According to EN 81 1 2 standards the deactivation of cabin lamp delay in manual doors is prohibited In lifts with simple control without collection this parameter should be kept same with WAITING TIME IN THE STATION and set to at least to 2 seconds After door closed signal has given the maximum time to be waited for arrival of lock
17. his parameter 31 RP Delay In roped VVVF systems it can be wanted the delayed fall of the main contactor In such cases Rp relay out delay is set from this parameter It is used as motor delay in hydraulic lifts e 00000 25000 Milliseconds 1 You can set the movement style of lower upper limit breakers in revision by this parameter e UNTIL BREAKER As soon as breakers cut lift is stopped before reaching the floor e UNTIL THE FLOOR Even if the breakers cut 32 Rev Movement Style it the lift goes until its floor T __ _ _ _ To activate the early door opening function this parameter is used for roped VVVF and Hydraulic Lifts 33 Early Door Opening e CANCEL Early door opening is cancelled e ACTIVE Early door opening is active For early door opening the cabin movement with opening door is allowed only within the limits of door opening area and under the control of door bridging circuit on HEYTEC HT 53 when lift speed is under 0 15 m s 34 Star Triangle In hydraulic systems by this parameter you can set the time that the motor will wait before starting the triangle connection after completing of star connection Second for hydraulic systems e 00000 25000 Milliseconds srame In hydraulic systems the delay of valves is set from this parameter during departure Second for hydraulic systems e 00000 25000 Milliseconds 35 Motor Valve Time
18. icate Number M201 4 103 37B4 UDEM intermationor Certification Initio Assessment Date 17 11 2014 Auditing training Centre Industry Registration Dote 27 11 2014 and Trade Co Ltd Reiswe Date No Expiry Date 26 07 2015 he carey of tw cordes conste checa Woo cvv odictor Par ea paway or fe api r t s omo t ru ts emporsils od hen oc m d Fe co mh OX Om e len d Contr ha rtt Green rh conta Pew nop of UW AAA Catfcofiun Acor ing Cente Ay et ete Co Lio dor me Cem mec opo comet Phe chowe normae mal bep o oxy o te scan tor 13 youn Son few mazi of een The gare cured es mai noy of changes ied weh fee antreved be WORM F UD we HI nme debe of Hh m omm Addmes Mutizent Meni 2073 Soo Evi 93 Sok Mo 10 Conaye TURKEY Phone 00 312 44300 77 fax 90 312 441 87 72 Bengi iniodudemitd com www demi com tr 29 heytech HEYTECH ELEKTRIK ELEKTRONIK Sanayi Ticaret Sti Altinsehir Mahallesi Kumru Caddesi Ceylan Sokak No 66 A mraniye stanbul T RK YE TEL 90 546 861 65 83 90 545 207 20 28 90 542 765 63 86 E mail intfo heytechelektronik com www heytechelektronik com 30
19. in contactors EN Encoder Supply Voltage Output 5v dc EN Encoder Supply Voltage Output 5v dc ENA Encoder A channel ENB Encoder B channel HT 53 Symbols of the Serial Card S1A Communication Input S1B Communication Input 1000 Signal Circuit Ground 100 Card Supply Input 24vdc 2 Cabin Lamp Output 1 Cabin Phase Input A3 A Door Opening Signal Output A5 A Door Closing Signal Output A15 A Door Signal Joint Input B3 B Door Opening Signal Output B5 B Door Closing Signal Output B15 B Door Signal Joint Input 401 420 Cabin Inside Button Inputs 2G 7 Segment Digital Output 2BC 7 Segment Digital Output G 7 Segment Digital Output F 7 Segment Digital Output E 7 Segment Digital Output D 7 Segment Digital Output C 7 Segment Digital Output B 7 Segment Digital Output A 7 Segment Digital Output 32 Up Arrow Signal Output 31 Down Arrow Signal Output 02 Out of Service Signal Output 01 Overload Lamp Output AKU Accumulator Input AKU Accumulator Input 12V 12V Output 12V 12V Output AA Emergency Lighting Lamp Output AA Emergency Lighting Lamp Output AB Alarm Button AB Alarm Button 500 Revision Down Direction Signal Input 501 Revision Up Direction Signal Input 803 Minimum Load Signal Input 80
20. line Correction 53 Floor Rising Correction 54 Audio Settings 55 Deceleration Coefficient 56 UCM TEST 57 Restore Factory Settings HT 53 TECHNICAL SPECIFICATIONS 20 Control Supply Voltage 24 5 Vdc Power Consumption Max 400mA 10W for 24V Safety Current Tension 230Vac Control Signal Input 24 5 Control Signal Output 24 5 Emergency Lowering Voltage in Hydraulic 24Vdc 2 row 16 characters LCD screen and 6 button keyboard RS 485 series communication for group working RS 485 serial communication with cabin for serial installation connection In built door bridging safety circuit In built phase ordered motor protection circuit In built control inputs and outputs for two automatic doors Digital and signal outputs with short circuit protection 7 segment adjustable from menu for indicators Gray and Binary code outputs Emergency lowering with ups support in hydraulic lifts Recovery function by vvvf driver in roped lifts KEYBOARD FEATURES Menu can be adjusted via the keyboard easilyand error records can be seen record can be given to the desired station and lift can be observed e Entering to the menu Press the Enter button to enter the menu e Exit the menu Press the Esc button and then Enter button to exit the menu e Entering to Manuel movement Enter to revision movement via the card by pressing Ecs button for 3 seconds e Well copying Press on Esc button for 2
21. ounter is reset For example in the systems that has accumulator recovery units position reset can be made by activating this parameter S1 Regulatur Tom If this parameter is active the regulator monitoring contacts should be connected If it has been cancelled it will not detect any error in case of falling in a3 involuntary status For this reason do not cancel it If it is cancelled our firm will not be responsible While it is active the lift will not depart before taking of regulator coil pulled information For this reason check RGA led if it lights or not during operating If the lift counter type is encoder floor descent settings can be made by means of this parameter If the lift is in upstairs enter and in downstairs enter mm 52 Floor Descent Correction CT If the lift counter type is encoder floor ascent settings can be made by means of this parameter If the lift is in upstairs enter and in downstairs enter mm 53 Floor Ascent Correction 18 54 Audio Setting If the lift has HT ANNOUNCEMENT card it can be controlled by this parameter e There is no sound card it is selected if there is no announcement card e Only announcement Only floor announcements are read e Only background music Floor announcements are not read Only background music plays e Announcement background music Both floor announcements are read and background music is played 55 Deceleration ee E
22. reaching this number the record coming from cabin inside will not be given e You can enter a value between 01 20 41 Max Internal Record stations 16 This parameter is used to retard the movement of the lift after arriving of 130 and 140 safety circuits e 0000 1000 Milliseconds ELLL a 42 Safety Delay If this parameter is active the break monitoring points should be connected In case of falling in a3 involuntary in gearless machines the error will not be detected while the cancel status For this reason it should not be cancelled If it is 43 M Break Monitoring cancelled our firm will not be responsible NOTE If there is break monitoring error press ESC button for 30 seconds e CANCEL It is cancelled e ACTIVE It is active 4 d The selection of the lift floor detection is made by means of this parameter e STANDARD Standard MO counter e STANDARD M1 Standard M1 counter e ML1 amp ML2 ML1 ML2 counter Conform to A3 Standards for hydraulic e ENCODER used in well copying conform to A3 Standards J d OPO 45 After Going Jf In low speed lifts if the stopper magnet f distance is insufficient the stopping distance is increased with this p
23. seconds while the lift is in revision HT 53 Symbols of the Control Card R S T Main Phase MP Neutral 10A Safety Circuit Neutral Return Neutral Output of the Contactors 120 Stop Circuit max 230vac 130 Door Plug Contact Circuit max 230vac 140 Door Lock Circuit max 230vac PTC 1 Motor Thermistor amp Panel Thermostat amp Oil Thermostat Hydraulic amp Break Resistance Thermostat PTC 2 Motor Thermistor amp Panel Thermostat amp Oil Thermostat Hydraulic amp Break Resistance RBO Regulator Coil Joint RBA Regulator Coil Openness LO Door Pump Relay Contact Joint LA Door Pump Relay Contact Openness RPA Engine Contactor Output is Used In VVVF and Hydraulic RPA RPB RPB Engine Contactors input RPO RPA RLA Spare RLB Spare SAK Main Phase Active Contactor KAK Rescue Active Contactor KSO KAK SAK Joint UP Up Direction Relay Output DWN Down Direction Relay Output V3 High Speed Relay Output V2 Intermediate Relay Output V1 Revision Speed Relay Output VO Low Speed Relay Output PIN Error Reset not used EN Releveling Relay Output COM V0 V1 V2 V3 En Relay Joint 100 Card Supply Input 24v dc 1000 Signal Circuit Graund HZR Ready Information Coming From the Driver KRC Feedback Input of the Main Contactor The 100 signal should be connected to this input by series passing the closed contacts of the ma
24. station digit flashes and then come upon the door value by pressing RIGHT button Determine the door the will be opened by utilising again UP DOWN buttons e A B AB 22 Door Special Setting 13 23 Saver If the lift will be used for rescue this option is activated R You can set the group identification of the control panel during group working Group identifications can be as A B C D E or F The identification of each lift should be different In the records at the same distance the priority is 24 Duplex Selection given to the lift which has low group identify m2 CONG Gong signal is set with this parameter You can utilise this parameter to activate leak of 26 Phase Protection phase and phase sequence control e CANCEL Deactivated e AKTIVE non phase sequence e AKTIF phase sequence 1 motor thermistor input is CANCELLED ACTIVATED with this parameter e CANCEL Deactivated e ACTIVE Activated 27 Ptc 1 28 Cabin Serial Card It is reported to the main card in which the serial communication cards is inserted by this parameter If serial card is inserted this parameter is activated By this parameter the time period from the opening of the door until stopping is entered e 05 20 Seconds 29 Auto Door Opening Time 14 30 Sing e DOO E In swinging door lifts if the lift has a single automatic door the automatic part is determined by t
25. tic switches 1 Door Opening Area Magnetic Switch ML1 ML2 2 Course Magnetic Switches 141 142 3 Level renewal can be used 4 Apply the arrangement in the example for each floor 1 Arrangements of the floor level magnets 30 cm strip magnet Monostable ML2 Monostable 1 Cabin Dz amm Floor level 2 Arrangemenis of thefloor level magnets monostable 3cm n 1 FLOOR LEVEL 7om FLOOR LEVEL CABIN 22 2a Arrangement of the deceleration way magnets 141 142 monostable I I 1 1 I Deceleration distance 1 I Cabin a 1 1 1 i 1 Deceleration distance 1 1 1 i 1 1 1 cec Floor level 23 INSTALLATION FOR ENCODER COUNTER SYSTEM In encoder counter systems cabin movement and floor information are detected with 2 type magnetic switches 1 Door Opening Area Magnetic Switches Encoder or ML1 ML2 2 Course distance and stoppings are determined with encoder DOOR OPENING AREA MAGNETIC SWITCHES ML1 ML2 1 ML1 Monostable 2 ML2 Monostable id est 2 in total NO normally open The function of this switch is to give the information that the cabin is within the limits of door opening to the control panel Installation of the magnetic switch 1 Place ML1 and ML2 magnetic switch on the carcase so that it see one side of the rail 2 Connect the switches ends respectively to ML1
26. ut B Channel Mechanical Break Control Input for Synchronous Motor Spare 7 Segment Digital Output 7 Segment Digital Output 7 Segment Digital Output 7 Segment Digital Output 7 Segment Digital Output 7 Segment Digital Output 7 Segment Digital Output 7 Segment Digital Output 7 Segment Digital Output Gray amp Binary Code Outputs set the menu Gray amp Binary Code Outputs set the menu Gray amp Binary Code Outputs set the menu Gray amp Binary Code Outputs set the menu Gray amp Binary Code Outputs set the menu Down Arrow Signal Output Up Arrow Signal Output Out of Service Signal Output gt lt gt lt 0 eS IN w NNI BONO OD e XD 24v dc Inputs Outputs Signal Circuit Ground Inputs Outputs OPENING SCREEN When power is given the system the SPLASH SCREEN HEYTECH HT 53 will be appeared on the LCD screen On this screen the software version of the card and serial number are shown SERIAL NO 01 01 2014 After waiting for 2 seconds the screen will select the display called as MAIN SCREEN MAIN SCREEN RECORD WAITING On the main screen the station number where the lift is and the supply tension of control card are shown D 10 24 0 V REVISION FRON THE CARD Take the lift to the position of revision from card b
27. y pressing on ECS button for 2 seconds and then move it by up down buttons REVISION FROM THE CARD D 10 24 0 V RECORD FROM BUTTONS Manuel Record gt 10 When press U Down button manual record monitor will appear Select the station and then D 15 24 0 V press ENTER button GROUP WORKING DISPLAY Group AB P A On the screen the situations of six panels on the group working are as follow Eu 24 0V A B C D E F indicates group identification for for control panels A a Indicates control panel with communication whether it is included in group working If it shows lower case the lift is not included in group P A Indicates the group identification of the controller panel indicates existing or non communicating control panels indicates the communication speed PASSWORD DISPLAY gt 00000 I If there is a previously determined password enter your password by utilising the UP and DOWN buttons then press ENTER button for confirm the password If your password is entered correctly first parameter will be displayed on the screen If the password is entered incorrectly WRONG PASSWORD ENTRY DONE warning will appear and the card will return to the main screen Wrong password entering does not bloc your card The card continues to its work but the system does not allow to do any changes on the parameters You can obtain the correct password by sending the serial code to our firm
28. your motor has mechanical brake switches connect them This document has been prepared to inform the users HEYTECH cam make changes the content of the document if required L ST OF PARAMETERS 00 First Installation 01 Lift Type 02 Command Type 03 Number of Floors 04 Number of Basement 05 Door Type 06 Busy Time 07 Lock Waiting Time 08 Waiting Time on the Floor 09 High Speed Time 10 Low Speed Time 11 Door Maximum Time 12 Park Going Time 13 Parking Floor 14 Fire Park Floor 15 Direction Arrow Flash 16 Password Change 17 Paswword Cancel 18 Maintenance Done 19 Maintenance Time 20 Error List 21 Digital Settings 22 Door Special Setting 23 Rescue active passive 24 Group ID 25 Gong Signal 26 Phase Control 27 Ptc Thermostat 28 Car Serial Card 29 Auto Door Opening Time 30 Single Door Full Automatic 31 RP Delay gt gt gt gt gt gt for roped VVVF and Hydraulic Lifts 32 Revision Movement Style 33 Door Pre Opening 34 Star Triangle gt gt gt gt gt gt for Hydraulic Lifts 35 Engine Valve Time gt gt gt gt gt gt for Hydraulic Lifts 36 Door Open Releveling 37 The Bottom Floor 38 Early Opening Way 39 Call Transfer 40 G0 G1 G2 G3 G4 Outputs 41 Maximum Car Call 42 Safety Delay 43 Mechanical Brake Monitoring 44 Counter Type 45 Go After Jf 46 Photocel Time 47 KRC Contactor Control 48 Encoder Multiplier 49 Auto Door At Floor 50 Position Reset 51 Regulator Monitoring 52 Floor Dec
Download Pdf Manuals
Related Search
Related Contents
MANUAL DE INSTRUÇÕES Séries AR5 e AR5-L TELOS TWOx12 - magnetic media Headcount portal user guide, section 3: Children's data (adding ESTEREOMICROSCOPIOS STEREOMICROSCOPES InStyler® User Manual Star Dancer 『SOLA VIDEO 1200』の取扱説明書がダウンロードできます。 BOMBA ENERGETICAMENTE ULTRA EFICIENTA 鮫島正洋, 「技術者にとっての下請法改正」 Copyright © All rights reserved.