1. USER MANUAL Thank you for purchasing the My Weigh iBalance iM01 digital scale Please read all operating instructions carefully before use This electronic scale is a precision instrument With normal care and proper treatment it will provide years of reliable service For more information please visit www myweigh com Never load the scale with more than the maximal capacity Although the iBalance iM01 is designed to be extremely durable with extra overload protection built into the case overloading will permanently damage it Avoid any exposure to extreme heat or cold your scale works better when operated at normal room temperature Keep your scale in a clean environment Dust dirt moisture vibration air currents and or a close proximity to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale Handle with care Gently apply all items to be weighed onto tray top Avoid shaking dropping or otherwise shocking the scale Scales are delicate instruments and unlike cellular phones scales have delicate sensors that determine how much an item weighs If you drop or shock your scale these sensors feel the shock and are sometimes destroyed This happens with all digital scales We design our scales to be as resistant to shock or drops as possible however there is no way for us to protect 100 against load cell or sensor damage Failure to follow these instructions will void your warran
2. 20 HEX 20 HEX 67 HEX 4 Stop bit 1bit kg 20 HEX 20 HEX 6B HEX 67 HEX 5 Code ASCII ct 20 HEX 20 HEX 63 HEX 74 HEX DATA FORMAT ozt 20 HEX 6F HEX 7A HEX 74 HEX HEAD1 HEAD2 DATA UNIT CR CR 0A HEX OD HEX 123456789 10 11 12 13 14 15 16 17 18 19 20 HEAD1 2BYTES HEAD2 2BYTES TRANSMISSION EXAMPLE OL overload NT net weight mode stable net 0 168 g ST stable US unstable HEAD HEAD DATA UNIT CR ST NT 0 168g OA OD Capacity 1000gx0 01g Units g ozt ct Auto OFF 2min Scale dimension Tray dimension Net gross weight Operating temperature Power Source Tare range Zero range 1200g Optimum 10 40 C 50 104 F DC 6V 1 3Ah rechargeable sealed lead acid battery or 8 5V 0 2A AC DC power adaptor Up to scale s maximum capacity LIFETIME Y 200mm x 240mm x 80mm PRECISION 116mm diameter 0 01 g ort ane www myweigh com 5 of max capacity
3. e again to select your response speed nb0 slowest nb3 fastest Press 2 to confirm You will then go to select outer division The display will show d xxx xxx current division You can press to select and press E to confirm After that the scale will return to normal weighing mode RANGE OF ZERO TRACK AND ZERO DISPLAY SELECTION 1 Pressand hold 4 do not release and power the scale on with Wait until the display shows 0 5d 1 0d 1 5d 2 0d 3 0d Then press to select the range of zero tracking and press o to confirm 2 The display will then show ZEr S or ZEr L press to select the zero display range ZEr S means 0d and ZEr L means 3 0d Press Eo to confirm 4 To select the baud rate press you can choose between 1200 2400 and 9600 Press to confirm 5 You can choose the communication method by pressing 2 to rotate revolve Co send in succession st send steadily press fe for confirmation After that the scale will return to normal weighing mode DATA TRANSMISSION SERIES RS 232 INTERFACE only for communication 1 iBalance EIA RS232 Cs UART signal DATA 8BYTE 2 Format 2D HEX negative sign 20 HEX blank 1 Baud rate 1200 bps 2400 bps 4800bps 9600 bps 2E HEX decimal point 2 Data bits 8 bits UNIT 4 byte 3 Parity bit none g 20 HEX
4. e unit may return to normal operation Remember You can permanently damage the scale and void your warranty by overloading it The LCD will display ERR 1 if the weight placed on the platform is incorrect during calibration POWER SUPPLY The iM01 is powered by the DC 6V 1 3Ah rechargeable sealed lead acid battery or directly by the 8 5V 0 2A AC power adaptor When the symbol appears it indicates that the battery needs to be recharged The balance will automatically shut off when power voltage goes down to 5 2V 0 15V Low voltage may also cause inaccuracy or instability CALIBRATION Press and hold do not release and power the scale on with release fo when the LCD shows CAL 2 Press 2 again it shows 000000 This is where you would input the calibration weight you are going to use to calibrate 500 grams is recommended Use to cycle through the 6 zeros shown on the screen and use f on the selected digit to adjust selected digit To calibrate a the recommended 500 grams the screen must read 000500 Once this is set place the 500 gram calibration weight on the tray 3 Wait for 3 seconds then press 4 to finish the calibration process T F WEIGHT RESPONSE SPEED Press and hold do not release and power the scale on with Wait until the display shows nb0 nb1 nb2 ornb3 You can now release 2 Press
5. s recharging CB The display reading is STABLE pcs Scale is in COUNT mode ct Unit is CARAT ozt Unit is TROY OUNCE g Unit is GRAM Incharge Scale is in the process of RECHARGE PROTECTION SCREW on the left side of the scale WSs ADJUSTABLE FEET on bottom of each corner of the scale e DATA TRANSMISSION PORT on right side of the scale KEYPAD FUNCTIONS ON OFF power switch SAMPLING amp COUNTING UNIT g ozt or ct selection 9 OF TARE is used to deduct the weight of an item or container The symbol gt will appear and reading will go to zero Press it again to exit the tare mode when empty the tare indication will disappear ZERO is used to return the display to zero if a small weight reading is left while unloaded empty COUNTING FUNCTION 1 Press 4 the display will show 10Cnr means sample size is 10 pcs 2 Press again and again 10 20 50 100 pcs will appear in succession Stop at the one you want to use 3 Put the exact quantity of samples desired on the platform and press the set sample size will appear 4 Keep adding objects to be counted on the pan the total number of the objects will be displayed If the unit weight is too small for the counting resolution the display will show ErrPcS ERROR MESSAGES When an applied load exceeds the capacity 9 will appear on the display Remove excessive load immediately Th
6. ty Always allow the scale to acclimate to normal room temperature for at least one hour before use Give your scale sufficient warm up time Usually 30 60 seconds before calibration to give the internal components a chance to stabilize PRECAUTIONS BEFORE USING THE BALANCE 1 Matter charged with static electricity can affect accuracy Discharge all static electricity For example one method is to use Static Guard spray and spray it on both sides of the weighing platform 2 Before the initial use please remove the protection screw Re install this screw before transport to help avoid possible damage 3 The balance must be in an exactly horizontal position in order to achieve accurate measurement results In order to bring the balance into a horizontal position the adjustable feet are turned either clockwise or counter clockwise until the air bubble on the front panel is in the center of the marked circle 4 Please use an independent power outlet to avoid interference from other electrical appliances 5 Don t put any object on the platform before powering on 6 When possible please allow the scale to warm up for several minutes before operation 7 Items should always be placed on the center of the platform when being weighed 8 For optimum accuracy recalibrate before each use SCALE FEATURES OPTIONAL CLEAR WIND SCREEN AIR BUBBLE LEVEL DISPLAY SYMBOLS 0 Scale is in ZERO mode gt Scale is in TARE mode oo BATTERY need