ST50737-M Chore-Logic H

image

Contents

1. Turn on power Each time the power is connected to the unit the version number will briefly appear on the display r321 After 5 Seconds the unit will display the current temperature for the two connected sensors The sensor reading will alternate between sensor 1 used for ventilation heating and cooling and sensor 2 which is used for the Floor pad heating system Sensor 1 is shown on the display with a small line at the top of the readout Sensor 2 is shown on the display with a small line at the bottom of the readout Example Sensor 1 air temperature 79 0 F Sensor 2 floor temperature 73 0 F 2 Recalling set points It is possible to recall the different set points programmed in the H VC5 and display them on the front display panel Press once on the button The top first led will light up The set value for the corresponding function will appear on the display Each time the button is pressed the next led will light up showing on the display the set value for the corresponding function There are seven functions that are represented by one led only 1 Required temperature led 1 2 Heat set point led 2 3 Fan 1 set point led 3 4 Fan 2 set point led 4 5 Cool temperature setting led 5 6 Coolon time led 6 7 Cool off time led 7 The eighth time the button is pressed two led s will light up The set value for the corresponding function will appear on the display There are five functio
2. system will turn on for two minute and then off for five minutes see cool off time Cool off time led 7 on This is the off time period set in minutes which the cooling system will be off cycle during the cooling system cycle Example Cool off time 005 If the house average temperature rises to the set Cool temperature setting then the cooling system will turn on for two minute see cool on time and then off for five minutes Cool system countdown timer In order to see how much time is left in the current cooling mode follow these steps 1 Enter the Cool temperature setting led 5 function 2 Press on Enter On the display will appear the the countdown timer for the cooling system To exit press on any button Alarms The H VCS has three built in alarms 1 Low temperature alarm to cold in the house 2 High temperature alarm to hot in the house 3 Floor heat pad connection problem Alarms 1 2 and 3 will appear on the display if activated Example Required temperature 79 F Low temperature alarm 2 If the average house temperature drops to 77 F the alarm relay will be activated and on the main display will flash the current temperature and the alarm number as shown here T77 0 gt ALO1 Alarm Low led 1 and 2 on Alarm low set point is the temperature differential below the reguested room temperature Example Alarm low 5 09 If the average temperature drops 5 0 below the reguired room t
3. User s Manual H VC5 Chore Logic H VC5 User manual CHORE LOGIC Reg Alarm Lew Heat Alarm High Van A Floor Heat Fan 2 Fan Os Tm Coel Temp Fan Off Tm Cod On Te Con Off Te Part No 50737 Version HPS 11 11 2006 User manual 1 02 ST50737MA 3 07 Page 1 User s Manual H VC5 Warranty Chore Time Hog Production Systems a division of CTB Inc Chore Time warrants each new Chore Time product manufactured by it to be free from defects in material or workmanship for one 1 year from and after the date of initial installation by or for the original purchaser If such a defect is found by Chore Time to exits within the one year period the Chore Time will at its option a repair or replace such product free of charge F O B the factory of manufacture or b refund to the original purchaser the original purchase price in lieu of such repair or replacement Labor cost associated with the replacement or repair of the product are not covered by the Manufacturer Conditions and Limitations 1 The product must be installed by and operated in accordance with the instructions published by the Manufacturer or warranty will be void 2 Warranty is void if all components of the system are not original equipment supplied by the Manufacturer 3 This product must be purchased from and installed by authorized distributor or certified representative the
4. cable The sensor has no polarity Sensor 1 Sensor 2 Drawing 2 J18 Temperature sensor jumper If a temperature sensor or its cable is disconnected or shorted the sensor reading will display OPEN Page 4 User s Manual H VC5 3 Connect the OUT phase neutral and ground to the Floor heat pad see drawing 3 Maximum output 20 AMP Be sure that the side heat sinks bars and fan are in an open area with proper ventilation Drawing 3 Connect 110V Connect the phase neutral and ground wiring coming from the Floor heating pad here Maximum output 20AMP Page 5 User s Manual H VC5 4 Connect the alarm relay output to the alarm system of your choice The alarm relay is a dry contact 2 Amp 220V NO NC see drawing 4 5 Connect a 110V cable to the unit 6 Connect the PC communication wires optional see drawing 5 7 Close the panel with the two screws Drawing 4 Heat Fan1 Fan2 Cool Alarm Relay inputs Maximum 2AMP Drawing 5 gt ELA gen s mn Connect the 5 wires to the AG box supplied separately optional Connect A to A B to B and so on for each of the 5 wires Page 6 User s Manual H VC5 Operation The H VC5 will display the current air temperature sensor 1 and current floor temperature sensor 2 The temperature reading can be displayed either in Celsius or Fahrenheit see Temperature setup page 11 If there is an alarm the unit will display the alarm number
5. cycle mode see ventilation In order to see the fan cycle countdown timer in seconds follow these steps 1 Enter the Fanl Off Time setting led 5 and 6 function 2 Press on Enter On the display will appear the output in percentage To exit press on any button Example of ventilation program Example Required temperature 79 F Fan 1 1 0 Fan 2 2 0 Fan1 On Time 005 Fan 1 Off Time 003 Room temperature up until 80 Fan 1 running in a cycle mode of on 5 minutes off 3 minutes Between 80 81 Fanl running nonstop 81 Fan group 1 and 2 running nonstop Page 10 User s Manual H VC5 Temperature setup It is possible to program the unit to display a temperature reading in Celsius of Fahrenheit Enter the Net name mode Press at the same time buttons Enter plus and minus Use the Net name 100 to set the temperature reading to Celsius Use the Net name 101 to set the temperature reading to Fahrenheit Page 11 User s Manual H VC5 5 Wiring diagram Chore Logic H VC5 0 5 AMP Fuse ceo 20 AMP Fuse Floor heat pad o N ij MONO ING NOG NOINO SUING NO CNG NO O GO 1 GND 2 A B C GND Heat Fani Fan2 Cool Alarm Y Y PC COM 110V Room Floor AG BOX IN sensor sensor ANALOG INPUT Page 12
6. emperature the alarm relay will be activated The corresponding alarm number will appear on the display Page 9 User s Manual H VC5 Alarm High High alarm set point is the temperature differential above the reguested room temperature Example Alarm High 5 0 If 5 0 is entered in the alarm high function then if the temperature rises to 5 0 above the reguired room temperature the alarm relay will be activated The corresponding alarm number will appear on the display Floor Heat temperature The floor heating pad system uses only the sensor 2 measurement Enter here the desired temperature Celsius or Fahrenheit that is reguired for the floor heating system If the sensor 2 measurement is less than this setting the control unit will increase the output power to the floor heating system until the desired temperature is reached If the measured temperature reading is to high the unit will reduce the output power until the desired temperature is reached In order to see the output reading in percentage follow these steps 1 Enter the Floor Heat setting led 3 and 4 function 2 Press on Enter On the display will appear the output in percentage To exit press on any button Fan 1 On Time Fan 1 on time is set in minutes This is the on time for fan 1 when it is running in the cycle mode see ventilation Fan 1 Off Time Fan 1 off time is set in minutes This is the off time for fan 1 when it is running in the
7. ns that are represented by two led s 8 Alarm low set point led 1 and 2 9 Alarm high set point led 2 and 3 10 Floor heat pad temperature led 3 and 4 11 Fan 1 on time led 4 and 5 12 Fan 1 off time led 5 and 6 3 Changing set points 1 Go into the desired function as explained above 2 Press on PROG button The display will start to flash 3 Use the and buttons to set to the desired values Page 7 User s Manual H VC5 4 Check the display to see if the information is correct If yes press on the Enter button The display will stop flashing to indicate that the new information has been stored into the unit s memory 4 Functions Required temperature led 1 on This is the required house temperature This temperature may be set either in Celsius or in Fahrenheit See Temperature setup page 11 This is set as an absolute temperature Example Required house temperature 88 0 enter 88 0 Heat led 2 on Heat set point is the temperature differential below the requested room temperature that the heating system will turn on Example Required temperature 86 Heat set point 1 0 If the room temperature should drop 1 0 below the Required temperature setting 85 then the heating system will start to run Ventilation The ventilation system will run according to the temperature reading of sensor 1 Fan group 1 will run in a cycle mode see Fanl on time Fanl off time as l
8. ong as the average house temperature is less than the set Room Temperature plus the set point of Fan 1 Once the house temperature is at the reguired room temperature plus fan 1 set point fan 1 will run nonstop If the set point for Fan2 is reached than fan group 2 will come into operation Fan 1 led 3 on Fan 1 set point is the temperature differential above the required room temperature at which time fan 1 will come into operation Example Room Temperature 79 F Fan 1 1 0 Up until 80 fan 1 will run in a cycle mode From 80 fan 1 will run nonstop Fan 2 led 4 on Fan 2 set point is the temperature differential above the required room temperature at which time fan 2 will come into operation Example Room Temperature 79 F Fan 2 2 09 When the house temperature reaches 81 F fan 2 will come into operation Cool Temp led 5 on Enter here the temperature that when reached in the house the cooling system will start to run in its cycle mode This temperature is set as an absolute temperature Example Cool 82 F If the house temperature rises to 82 F the cooling system will turn on and work according the preset Cool on and off time Page 8 User s Manual H VC5 Cool on time led 6 on This is the ON time period set in minutes which the cooling system will be in the on cycle Example Cool on time 002 If the house average temperature rises to the set Cool temperature setting the cooling
9. reof or the Warranty will be void 4 Malfunctions or failure resulting from misuse abuse negligence alteration accident or lack of proper maintenance or from lighting strikes electrical power surge or interruption of electricity shall not be considered defects under the Warranty 5 This Warranty applies only to the system for the care of poultry and livestock Other applications in industry or commerce are not covered by this Warranty Chore time shall not be liable for any Conseguential or Special Damage which any purchaser may suffer or claim to suffer as a result of any defect in the product Conseguential or Special Damages as used herein included but are not limited to lost or damaged products or goods costs of transportation lost sales lost orders lost income increased overhead labor and incidental costs and operational inefficiencies THIS WARRANTY CONSTITUTES THE MANUFACTURER S ENTIRE AND SOLE WARRANTY AND THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR OUILTY OF THE PRODUCT FURNISHED HEREUNDER Chore Time Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any manner or to offer or grant any other warranties for CHORE TIME6 products in addition to those terms expressly stated above An officer of CTB Inc mu
10. st authorize any exceptions to this Warranty in writing Chore Time reserves the rights to change models and specifications at any time without notice or obligation to improve previous models Effective 07 04 Chore Time Hog Production Systems A Division of CTB Inc 410 N Higbee Street Milford Indiana 46542 U S A Phone 574 658 5433 Fax 574 658 5325 Email hog choretime com Internet http www choretimehog com Page 2 User s Manual H VC5 OPERATION MANUAL Version HPS The H VCS is a stand alone climate control unit The unit has 5 outputs and two temperature sensors The unit has a built variable output regulator The unit has a built in alarm for low and high temperatures variable output regulator failure and power failure 1 Installation sists giau mn pa aa aan 4 2 Recalling s t POIs anseasrsnren ende dateerde entend BNN BNN 7 3 Chan ping setpoints Lantai arn him nda nam che ieee neuen aa 7 4 PU Na ennen rend OO NU NU eetl I FT naa enn 8 5 Wiring diagramau iden exited Sha aa alasan 12 Page 3 User s Manual H VC5 1 Installation Open the two screws on the front panel 1 Connect the H VC5 to the wall in a dry place at least 1 meter away from the electrical cabinet 2 Connect the temperature sensors to the temperature sensor inputs IN1 and IN2 See drawing 1 TEMP jumper J18 must be shorted out See drawing 2 The sensors can be placed up to 100 meter from the main unit with an ordinary two wire

Download Pdf Manuals

image

Related Search

Related Contents

LG HX301G  OMG-COMM8 operator`s manual  Series 5000 MCA User`s Manual  FirstClass Client for Mac OS USER REFERENCE CARD  VOICE MANAGER Voice Mail User's Manual  N8171-34 取扱説明書 15型液晶ディスプレイ  Type: ZHC900  5 juin 62 sram 71 juiN  Betriebsanleitung DMT 5/10_DML 40  Manual de Usuario sobre el PC Portátil  