DIP-34A
Contents
1. Time 10 s max Ingress Protection Rating IP 41 Input Voltage from a S2000 KDL 8 10 VDC Current Consumption via the loop of the S2000 KDL 0 5 mA max Pre operation Time 60 s max Operating Temperatures 30 to 55 C Storage Temperatures 50 to 55 C Humidity 93 at 40 C non condensing Overall Dimensions diameter x height 100x46 mm max Weight 0 2 kg max Average Lifetime at least 10 years DIP 34A VIEW AND DIMENSIONS A D l 110 LALLA IAK IID RRL a 7 106 P 7 4 N Hi IN Soe oo LA IN x an ey Wn Pa 8 cere a E O a x 30x lt i 1 DIP 34A Smoke Detector 5 Mounting Base 2 Light Emitter 6 MK 1 Suspended Ceiling Mounting Kit 3 Base Aligning Mark by Light Emitter 7 MK 2 Suspended Ceiling Mounting Kit 4 Mark and Rectangle Open here are purchased separately Figure 1 Three Ways to Mount the Detector MOUNTING A DIP 34A is to be mounted on a ceiling at a distance of no more then 4 5 m from the wall In such a case the protected area is 85 square meters provided the height of the ceiling doesn t exceed 3 5 m There are three ways to mount the detector see Figure 1 To set the detector to a solid surface variant A use the mounting base provided see the drilling pattern in Figure 2 For doing this match the detector mark with the short mark line on the mounting base and then turn the detector clockwise until the detector mark will
2. be aligned with the mark 3 as shown in Figure 1 A To build the detector into a suspended ceiling use separately purchased mounting kits MK 1 variant B or MK 2 variant C AL i ios ar i e 2 holes aay k 4 A ais ane Pa 2 TT be LO A a 110 z a NZ a ha Figure 2 Drilling Pattern WIRING Figure 3 shows the wiring diagram to connect DIP 34A detectors to the multiplex addressable loop of a S2000 KDL controller Addressable Device DIP 34A DIP 34A Figure 3 Wiring Diagram PROGRAMMING In order the DIP 34A to operate properly within two wire addressable loop of the S2000 KDL controller it must be assigned to a unique number from 1 to 127 within the loop the address which is stored in the DIP 34A non volatile memory This address provides identifying the detector by the S2000 KDL controller Moreover a monitoring strategy must be defined which will be used by the S2000 KDL controller while processing signals received from the DIP 34A Programming the DIP 34A Address within the S2000 KDL Addressable Loop A DIP 34A is supplied with the default address of 127 This address value can be changed using either S2000 M console tools or PC tools such as UProg Configuration Tool In order to program the unique DIP 34A loop address connect it to a S2000 KDL controller which is in turns connected to a network controller a S2000 M console or PC under UProg software Then send one of the follow
3. DIP 34A Analogue Addressable Photoelectric Smoke Detector INSTRUCTION MANUAL Ed GENERAL DIP 34A Analogue Addressable Photoelectric Smoke Detector hereinafter referred to as the DIP 34A or the detector is designed to be used in a fire alarm system in order to initiate fire alarms The DIP 34A operates under control of the S2000 KDL controller which the detector is connected to and which supplies power and communicates data with the DIP 34A via the two wire multiplex addressable loop Up to 127 DIP 34A detectors can operate under a single S2000 KDL The DIP 34A detects smoke inside its smoke chamber by sensing light reflected by smoke particles and responds with its statuses to the S2000 KDL controller Depending on detected smoke amount these statuses can be Norm Fire Prealarm or Fire Alarm In addition the detector can respond with the condition of its smoke chamber is it dirt or dust The area protected by a single DIP 34A is approximately 85 m unless it is set higher than 3 5 m The DIP 34A supports DPLS_v2 xx Multiplex Addressable Loop Protocol enabling monitoring addressable loop voltage at the detector location The version of DIP 34A software is 1 20 The detector operability must be periodically tested either by using test aerosol as described below or by means of a laser test tool such as the test tool produced by the System Sensor Company SPECIFICATIONS Sensitivity 0 05 0 2 dB m 1 2 m to 4 7 m Response
4. al purchase under normal use and service Seller s obligation is limited to repairing or replacing at its option free of charge for parts or labor any product proven to be defective in materials or workmanship under normal use and service Seller is not responsible for results where the product is used improperly where it is used for any application it is not intended for used under unacceptable environmental conditions and mishandled or stored under improperly Seller shall have no obligation under this warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than the Seller In case of defect contact the security professional who installed and maintains your security equipment or the Seller for product repair This one year Limited Warranty is in lieu of all other express warranties obligations or liabilities There are no express warranties which extend beyond the face hereof Any implied warranties obligations or liabilities made by seller in connection with this product including any implied warranty of merchantability or fitness for a particular purpose or otherwise are limited in duration to a period of one year from the date of original purchase Any action for breach of any warranty including but not limited to any implied warranty of merchantability must be brought within 12 months from date of original purchase In no case shall seller be liable to anyone for any consequential or incidental da
5. cific legal rights and you may also have other rights which vary from country to country No increase or alteration written or verbal to this warranty is authorized
6. ing commands to the S2000 KDL controller for getting more information see the relevant user s Manual Change the Device Address Use the Change Device Address command specifying the old detector address and the new detector address as the parameters see more information in the referred Manuals The network controller will display the messages about disconnecting the device with the old address and then detecting the device with newly programmed address Program the Device Address If the device address is unknown or two devices have the same address then use the Program Device Address command specifying a required address as the parameter Then press the detector light emitter or send the laser test tool beam into it The message about detecting the device with the newly assigned address shall be displayed by a network controller S2000 M or UProg Configuration Tool Then write the address on the label and stick it on the detector base Programming the S2000 KDL to Operate the DIP 34A To handle signals from a DIP 34A correctly a S2000 KDL controller must be programmed with the Zone Type parameter for this DIP 34A being set to value 1 Smoke or 8 Smoke Analogue Addressable with Variable Thresholds To program the S2000 KDL connect it to a PC under UProg Configuration Tool and follow the relevant programming instructions in accordance with the S2000 KDL User s Manual DIP 34A ROUTINE TESTING Before testing DIP 34A please disconnect e
7. mages for breach of this or any other warranty express or implied or upon any other basis of liability whatsoever even if the loss or damage is caused by the seller s own negligence or fault Some countries do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Seller does not represent that the product may not be compromised or circumvented that the product will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Buyer understands that a properly installed and maintained alarm may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty gives you spe
8. t test mode when the S2000 KDL of versions 1 36 and above is in use see the Manuals for the S2000 KDL controller and the network controller When the aerosol is scattered or light emitter pressing is terminated or laser test tool is disposed the detector must enter Norm status If the network controller has displayed no messages mentioned above or the light emitter behavior differs from that mentioned above then the detector is defective and must be replaced MAINTENANCE Please test the detector operability annually as said above When a Service Required message is received from the detector remove the dust and dirt from the detector smoke chamber WARNINGS To avoid contamination of the detector please DO NOT remove protective cover until the environment will be cleaned from dirt and dust DO NOT remove the detector PCB because this automatically cancels the warranty iss DO NOT mount the detector within the premises where air velocity values exceed 15 m s ZAO NVP Bolid 4 Pionerskaya Str Korolev 141070 Moscow Region Russia Phone fax 7 495 513 32 35 Email info bolid ru overseas bolid com www bolid com SECURITY SYSTEMS BOLID ONE YEAR LIMITED WARRANTY Bolid Company and its divisions and subsidiaries Seller 4 Pionerskaya Str Korolev 141070 Moscow Region Russia warrants its security equipment the product to be free from defects in materials and workmanship for one year from date of origin
9. xecutive outputs of all system devices and modules that can release an extinguishing agent or activate light and sound alarms Notify the fire department and persons A where the audible signals can be heard After testing verify that all detectors are ready to operate properly Then restore operability of all the system components disconnected before testing and inform the relevant departments about completing the test To test the DIP 34A detector turn on the network controller and the S2000 KDL controller The light emitter of the detector will light steady When the communications between the detector and S2000 KDL will be set the light emitter will flash once per 4 seconds indicating Norm detector status Take a spray can of smoke detector test aerosol and spray some of the test material into the detector The network controller shall display Fire Alarm message for the device with the address of the DIP 34A The detector light emitter will flash double each 4 seconds Alternately you can perform a simplified test just by pressing the detector light emitter or lighting it with the laser beam of a laser test tool This will cause steady lighting of the detector light emitter followed by its double flashing each 4 seconds The network controller will display a Fire Alarm message for the device with the address of the DIP 34A when the S2000 KDL of versions 1 35 and below is in use Test message or Fire Alarm message depending on the curren