1. Cause The electromagnetic valve for the incoming water is stuck open because of dirt or electric fault See test 3 Action Remove the electromagnetic valve and clean it Fix the electric fault Cause The electromagnetic valve is broken Action Replace the electromagnetic valve Cause Fault in circuit board Action Replace the circuit board Warm water comes out of the steam nozzles in pulses or as weak continuous stream with steam Cause Small water pocket in the steam pipe Action Remove the water pocket Cause Too much of the steam pipe is uninsulated Action Insulate the steam pipe Warm water comes out of the steam generator s downpipe all the time Cause Automatic electromagnetic flushing valve is stuck open Action Stop the steam generator Try again after 80 minutes If the fault remains remove the automatic electromag netic flushing valve and clean it Banging noise from the water pipes when the electromagnetic valve opens or closes Cause Inadequate connection in the water pipe coming into the steam generator Action Mount the water pipe securely on the wall Cause Recoil effect in the incoming water pipe Action Install about 1 metre of pressure proof reinforced rubber hose into the steam generator end of the water pipe Safety valve opens or the overheating protector trips Cause Steam pipe is blocked See test 4 Action Remove the block Cause The inner diameter of the steam pipe is significa
2. C Light control option OLEA 72 max 24 V DC 50 mA 354 SHS 40C o ofo ol LC1LC2 B1B2 T1 Water valve Water valve flush filling 230V AC 230V AC HNS M2 3 4 7 7 kW 230V 240V 1N 2 230V 3 400V 415V 3N HNS M2 9 5 14 0 kW 230V 3 400V 415V 3N Steam generator 2 grade control Control of steam generator heat element has two grades Example The set temperature is 43 C When the temperature reaches 43 C two elements are switched off with the help of a contactor and one element retains the temperature with the help of another contactor If the temperature rises 1 C from the temperature set all elements are switched off When the temperature drops below 1 C all elements are switched back on This ensures stabile steam production for the entire duration of the operation User and installation manual HNS M2 9 Steam generator maintenance procedures The water tank of the steam generator must be drained after every use To prolong its service life and to reduce the need for manual decalcification we recommend that steam generators used in public facilities are connected to a water softening filter which removes the calcium This is especially important if the water hardness exceeds 7 dH German hardness Water softening filter must not generate foam or produce harmful chemicals which may give erraneous view of the water level in the tank and cause the heat coil fuse and heat elements to br
3. Remove the steam pipe from the steam generator Start the generator and let it run for about one hour If the safety valve or the overheating protector does not trip during the test there is a block in the steam pipe that prevents the steam flow Follow the instructions in the troubleshooting chart The product s warranty will be void if the steam generator has been incorrectly installed or it has been used in a manner other than described in the user manual The warranty also expressly excludes operational faults if they are caused by hard water i e water with high levels of chalk or otherwise impure water The steam generator must be maintained as described in the user manual User and installation manual HNS M2 ROHS Ymp rist nsuojeluun liittyvia ohjeita T m n tuotteen k ytt l n p tytty sit ei saa h vitt normaalin talousj tteen mukana vaan se on toimitettava s hk ja elektroniikkalaitteiden kierr tykseen tarkoitettuun ker yspisteeseen Symboli tuotteessa k ytt ohjeessa tai pakkauksessa tarkoittaa sit Valmistusaineet ovat kierr tett viss merkint ns mukaan K ytettyjen laitteiden uudelleenk yt ll materiaalien hyd ynt misell tai muulla uudelleenk yt ll teet arvokkaan teon ymp rist mme hyv ksi Tuote palautetaan ilman kiuaskivi ja verhouskivi kierr tyskeskukseen Tietoa kierr tyspaikoista saat kuntasi palvelupisteest Instructions for environmental protec
4. anual Steam generator in professional use In addition to decalcification treatment it is recommended to make a service plan for steam generators in daily use 6 hours or more Service is recommended to be done 6 times a year and it is to include visual inspection of the heating elements and the surface sensor inspection and cleaning lime accumulation of the inner surface of the tank and replacing components if necessary Tank cleaning is done through the heating element mounting holes User and installation manual HNS M2 Use of the steam generator HNS M2 Control panel Midi 2 RA 29 Lighting controls Temperature display Controls for tem Time display perature and time Temperature sensor On Off button Lighting controls Requires the light adapter 0043214 sold separately to function Temperature display Temperature range 30 50 C Display of time remaining Time setting 0 23 hours Use the plus button to increase temperature or time OK button accepts the modified setting or step forward e g for time settings Use the minus button to reduce the temperature or time On Off button to start or stop the steam generator 11 User and installation manual HNS M2 12 Three different uses of the controls Control panel Midi 2 On Off push button Control panel Midi 2 and On Off button together Control panel Midi 2 The steam generator is started by pressing the On Off button
5. ating time fixed 30 min The installation of the control centre and On Off push button in the steam room is allowed Easy maintenance Changeable resistors 3 pcs of which 1 is fitted with a heat fuse Fill cap for chalk remover citric acid has been placed on the upper part of the steam generator Components easily replaceable circuit board heating elements surface sensor Controls and accessories Control panel Midi 0043256 On Off push button 0043211 Sensor 0043210 Scent pump Essence kit 0038130 Scent pump canister 20 0038132 Automatic flush and rinse cycle Automatic drain valve 4310130 Steam nozzles 3 4 6 0 kW 1pc 7 7 9 5 kW 2 pcs 12 14 kW 3 pcs 7819604 Light adapter 0043214 Selecting the steam generator output for the steam room You can estimate the power requirement using the formula below Volume m x K1 x K2 Power requirement kW Forced ventilation K1 0 75 No ventilation K1 0 52 Acrylic wall K2 1 00 Light wall board tile K2 1 25 Heavy wall stone concrete tile K2 1 50 Very heavy wall stone concrete tile K2 2 00 In heavy built steam rooms it is recommended to use e g electric heating cable for warming the seats walls and floors Output Light struc Light board Heavy wall Steam ture acrylic wall tile concrete kg h tempered stone glass kW No A C Air condi No A C Air condi No A C Air condi tioned tioned tioned 18 30m 14 22 m 14 24 m 12 18
6. eak In normal private use the need for decalcification is minimal is the water is not particularly hard However the steam generator must be decalcified at least once a year This removes the calcium from the tank walls and heating elements Steam generator decalcification Start the steam generator and let it run until the water in the tank boils a Stop the steam generator Detach the lid nut of the pipe that travels through the steam generator lid Caution The lid nut is hot Pour the deliming agent e g citric acid into tank via the pipe using a funnel Attach the lid nut to the pipe and let the agent work e The steam generator flushes and rinses the tank automatically after about 15 minutes and you can use the steam generator again Acces sory Automatic drain valve Manual flush valve After boiling let the citric acid solution act in the tank for 15 minutes and flush the tank after that by opening the flush valve Close the valve after the first flushing and restart the steamer and allow the tank to fill up with water Repeat the process if necessary Citric acid deliming agent is odourless and harmless and it does not harm the steam generator s components If other type of deliming agent is used bathing during decalcification is not allowed As can be seen from the adjoining chart the need for manual decalcification depends on water quality steam generator output and operation time Operation time i
7. ect the downpipe copper pipe with a minimum diameter of 16 mm to the downpipe of the steam generator The downpipe is led to the nearest drain outside the steam room The temperature of the discharge water is 90 95 C IMPORTANT No stoppers valves taps etc may be fitted on the downpipe Regardless of where the downpipe is led it must fall all the way from the steam generator to the drain To ensure adequate fall you may have to place the steam generator on a wall mount or on a stand The steamer generator s tank should be drained after each use This extends the life cycle of the appliance and reduces scaling and the need for repair The product s warranty will be void if the steam generator has been incorrectly installed or it has been used in a manner other than described in the user manual The warranty also expressly excludes operational faults if they are caused by hard water i e water with high levels of chalk or otherwise impure water The steam generator must be maintained as described in the user manual User and installation manual HNS M2 7 Electrical connections The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations The steam generator is connected with a semi permanent connection Use HO7RN F 60245 IEC 66 or a corresponding type cables Output kW 3 4 4 7 7 7 9 5 Generator con nection cable HO7RN F 60245 IEC 66 mm 230V 3 Generato
8. h the door or a gap under the door The Exhaust valve is placed in the ceiling or on a wall near the ceiling as far from the supply air valve as possible however not above the door or the seats The exhaust valve is connected to an air conditioning channel going outside Forced ventilation If natural ventilation is not adequate e g negative pressure in the room where the fresh air is taken from the steam room must be equipped with forced ventilation Its output must be equivalent of 10 to20 m of ventilation per person per hour Testing the water before using the steam generator The test packet that comes with the steamer includes test slips which can be used for testing the water hardness number as follows Dip the test slip in water for about 1 second take it out and shake off the excess water After a minute compare the colour code appearing on the test slip with the code key in the packet Test result lt 3 dH Very soft water gt 4 dH Soft water Installing the decalcification device recommended gt 7 dH Medium hard water Install decalcification device and retest the water hardness gt 14 dH Hard water Install decalcification device and retest the water hardness gt 21 dH Very hard water Install decalcification device and retest the water hardness See page 9 for steam generator s operation time in hours before decalcification The steam generator must be placed away from water and moisture dry room The roo
9. helo GENUINE SAUNA amp STEAM User and installation manual HNS M2 STEAM GENERATOR CONTROL PANEL HNS M2 Midi 2 On Off push button For home and professional use 314 SHS 99 3A User and installation manual HNS M2 Contents Specifications Controls and accessories Selecting the steam generator output for the steam room General Installation principle Steam generator couplings Electrical connections Heating elements Switch diagram Steam generator 2 grade control Steam generator maintenance procedures Cleaning the steam room Steam generator in professional use Usage of steam generator HNS M2 On Off push button Error messages Installing control panel push button and sensor Troubleshooting Troubleshooting table ROHS oO CO GON Nn Oo on Ff oO ek Gk ek Rae OES N Pr W NNa O O User and installation manual HNS M2 Specifications Operating voltage 230 V 240 V 1N 2 3 4 kW 7 7 kW 230 V 3 3 4 kW 14 kW 400 V 415 V 3N 3 4 kW 14 kW Output options 3 4 4 7 6 0 7 7 9 5 12 0 14 0 kW Enclosure class IP 20 Installation Floor wall Water tank material Aisi 304 stainless steel Water tank pipes Aisi 314 acid resistant stainless steel Steamer dimensions 520 x 380 x 160 mm Weight when empty about 11 kg Easy to use Floor or wall installation Digital control panel Midi 2 operating time can be set between 0 23 hours On Off push button alternative method of control oper
10. in the control centre After that the temperature display starts to flash The temperature may be set with the and buttons in one decree steps between 30 C 50 C When the temperature figure on the display is correct use the OK button to move to the time display or wait for three seconds after which the time display starts to flash Time can be modified in one minute steps during the flashing using the or button up to 60 minutes after which the display will show hours up to 23 When there is 90 minutes left the display changes to minute display Before that only full hours remaining are shown When there is five minutes left the time display starts to flash to indicate that bathing time is nearly over You can use the On Off button to restart the steam generator if necessary The latest time and temperature settings are saved in the memory On Off button function If you use the On Off button only the steam generator will run for 30 ied ake minutes and stop automatically You start the steam generator by pushing 9 the button The LED light over the push button lights up to show that the steam generator has started Steam generator can be stopped by pressing the push button even before the 30minutes has run out in which _ case the light turns off Steamer can also be restarted if desired Nor A separate temperature sensor can be used with the steam generator if push the On Off button controls are used The sensor preven
11. m 10 14 m Table for selecting a steam generator based on the steam room volume and wall materials BE Eu aster eom aew orm sorm em e w BI w 5 10 13 16 9 User and installation manual HNS M2 General HNS M2 steam generators are only intended for use in heating spa facilities Using steam generators in other areas than steam rooms can damage the building s structure The manufacturer is not responsible for damages caused if the unit has been used incorrectly or in a manner for which the unit was not designed for Water and steam pipe connections must be made prior to connecting the unit into the mains Due care and attention must be taken when making the connections Proper sealing must be ensured for all extensions A good extension must have at least taped over threaded connections but it is recommended that connections are soldered Ventilation It is not normally necessary to arrange ventilation for steam saunas that are used for less than two hours steam rooms that are used for more than two hours at a time need ventilation for functional and hygienic reasons The ventilation recommendation is 10 to 20 m per person per hour If there is an empty space above the ceiling of the steam room it must not be completely sealed off Make at least one ventilation hole 100 mm x 100 mm into the empty space on the same wall with the door The Supply air valve may be a hole in the bottom part of the wall wit
12. m must be well ventilated as the unit also produces heat The maximum temperature of the room must not exceed 35 C Recommended minimum free space to sides and above the steamer is 30 cm Adequate space for maintenance should also be planned for in the placement of the unit There should be a drain nearby for draining the tank The steam generator can be installed freestanding on the floor or on the wall using wall fittings When using wall fittings ensure you use appropriate fittings and screws for the type of construction material of your walls The steam generator weighs about 17 kg when filled with water When the automatic drain valve is used it is recommended you use wall installation so an adequate angle can be ensured for draining of water User and installation manual HNS M2 Image of principle of installation Steam room Sensor Control panel i P Water connection ai dwer supply 2 N Flushing Locating the control panel Generator wall mounting Control panel is installed inside or outside the steam room model HNS M2 The cable of the control panel can be extended with an equivalent cable max 10 m The On Off push button can be used for remote starting and stopping of the steam generator the push button can be placed inside or outside the steam room For more detailed instructions see page 12 Steam nozzle nozzles are fitted approximately 200 to 400 mm from the floor underneath a bench or a seat or on
13. n hours before decalcification A water softener must be used in public facilities to reduce the need for manual decalcification In addition the automatic flushing valve Automatic Drain valve must be used Hours of operation different hardnesses Steam generator Amount of Softened water Soft water Medium hard water Hard water output kW deliming agent Citric acid 0 01 1 dH 1 3 dH 4 7 dH 8 14 dH 1 bag 50g 7000 2300 3800 1300 2600 1700 9 5 kW 1500 1300 1200 These service intervals are recommended by the manufacturer Decalcification may be performed more often if necessary The steam generator is ready to be used right after the calcification treatment If there is a lemon scent in the steam room after the treatment rinse the steam generator again Use of citric acid is not hazardous to health User and installation manual HNS M2 10 Flushing and rinsing HNS M2 steam generator has an option for an automatic flush and rinse cycle Accessory Automatic drain valve 15 minutes after the steam generator has stopped or has been stopped the electronic flush valve will open After the flush takes 4 minutes the steam generator will fill its tank again with cold water and flush it again rinse By emptying the steam generator s tank straight after use the product will gain a long life cycle even in areas where water quality leaves room for improvement Flushing the tank is not a substitute for a reg
14. ntly reduced See test 4 Action Replace the pipe or the connection where the inner diameter is reduced minimum inner diameter is 16 mm Cause Several sharp bends in the steam pipe See test 4 Action Make the bends less sharp Cause There is a large water pocket in the steam pipe See test 4 Action Install the steam pipe so that a water pocket does not form Steam generation is irregular from the beginning Cause The sensor is misplaced See test 2 Action Move the sensor or redirect the steam shower Cause Chalk or other impurities in the dirt filter Action Remove the dirt filter and clean it User and installation manual HNS M2 16 TEST 1 Checking chalk deposits in the water tank Open the top lock nut in the steam generator Lower a torch bulb that is connected to a battery with wires into the opening and light up the water tank s inside If there is more than 3 cm chalk on the bottom the steam generator has not been serviced and the chalk has not been removed according to the instructions It is also possible that the flushing and rinsing automation is not working Check that the steam generator power has not been switched off after bathing with a switch that may fitted in the supply line You can switch the power off from this switch only 80 minutes after the control panel has switched the power off Check the automatic flushing function by setting a bucket with a volume of about 12 litres under the downpipe Start
15. ooting operations Checks and troubleshooting In case of malfunction check that e the control panel and the steam generator are installed according to the connection diagrams e the steam generator is installed properly according to this instruction manual e the downpipe has adequate fall towards the drain e the dirt filter is clean The filter is in the incoming water connector Open the pipe connector for cleaning remove the filter and remove all the chalk and dirt from it e there are no water pockets in the steam pipe or in the outgoing air conditioning pipe e there are no sharp bends in the steam pipe bend radius must be at least 50 mm e any tap on the incoming water pipe to the steam generator is open e the steam room s structure and air conditioning match the installation and building instructions Troubleshooting chart Possible causes and suggestions for fixes Warming up takes abnormally long Cause Inadequate power output of the steam generator See output chart Action Replace with more powerful steam generator Cause Excessive ventilation of the steam room Action Reduce ventilation so that it is 10 20 m per person per hour Cause Blown fuse in the electrical cabinet Action Replace the fuse Action Replace the heating element Cause The sensor is too close to the steam shower See test 2 Action Move the sensor to another location or redirect the steam shower The steam room does not warm u
16. p or there is no steam Cause Action Cause Action Cause Action Cause Action Cause Action Cause Action Cause Action Cause Action Blown fuse in the electrical cabinet Replace the fuse No water is coming to the steam generator Open the incoming water tap The control panel is not set up right Check the time and temperature settings Dirt filter is blocked Remove the dirt filter from the incoming water connector and clean it The electromagnetic valve for the incoming water is stuck Remove the electromagnetic valve and clean it Too much chalk has accumulated in the steam generator s water tank See test 1 Clean the water tank and surface sensor s pin and replace the heating elements if necessary The steam generator is connected for incorrect voltage Check the voltage and the steam generator s connections See Connection diagram The overheating protector has tripped See test 4 Check and fix possible faults in the steam pipe e g blocks caused by several sharp bends water pockets or significantly reduces inner diameter of the pipe It is also possible that the tank has been filled with chalk accumula tion or impurities See the previous entry Cause Action Fault in the circuit board control panel or electromagnetic valve Replace the faulty part User and installation manual HNS M2 15 Warm water comes out of the steam nozzle and there is little or no steam in the steam room
17. r If the problem is located in the steam generator it may require maintenance or repair E2 Error message appears when serial communication between the control centre and the circuit board is not working Troubleshooting requires service The steamer stop after the error message Fix the cause of the malfunction or call service Malfunction can be confirmed with the ON OFF button In On Off button equipped steam generators the LED light flashes rapidly when the steam generator is indicating a problem The steam generator was started when the water tap was turned off or something else is preventing the water from running into the steam generator This notification appears when the steam generator is running if water intake is cut off The error message can be confirmed with the push button Fix the malfunction or have it fixed The circuit board has an output for alarm 24 V DC max 50 mA The output is activated when E1 or E2 error message appears on the display or when the led on the push button flashes rapidly User and installation manual HNS M2 13 Control panel Button and Sensor installation Mountin hole 5 mm The control panel is filled with sealing material making it moisture resistant The control panel may be installed directly on a wall The pipe hole in the steam room must be sealed to prevent moisture from travelling through the pipe into the structures The cable is left behind the control panel The cable can al
18. r con Fuse Fuse Generator connec Fuse Room nection cable tion cable size HO7RN F 60245 HO7RN F IEC 66 60245 IEC 66 mm mm J 400V 415V 3N A A 230V 240V 1N 2 A m EL o 2 e 2 BE ee ee i ee ee a Main switch There is a main switch at the bottom of one end of the steam generator which is used only when the steam room is not to be used for a long period of time The steam generator s automatic flushing and rinsing function will stop if the power is switched off Optional Automatic drain valve Steam generator s heating elements Teho Vastus Element Heizstabe 230V Power Leistung 1000W SEPD 131 1150W SEPD 97 1567W SEPD 98 2000W SEPD 99 2567W SEPD 100 5250W SEPD 116 4250W SEPD 119 5250W SEPD 116 1000W SEPD 130 1150W SEPD 111 1567W SEPD 112 2000W SEPD 113 2567W SEPD 114 3500W SEPD 115 3500W SEPD 115 3500W SEPD 115 1000W SEPD 131 1150W SEPD 97 1567W SEPD 98 2000W SEPD 99 2567W SEPD 100 5250W SEPD 116 4250W SEPD 119 5250W SEPD 116 User and installation manual HNS M2 8 Connection diagrams Contactor 3 4 7 7 kW 230 V 1N 2 1 ZICICICILIC Heating x 1 1 4 elements ft tf amp L2 L3 Main switch Lid 3 4 14 kW 400 V 3N grounding Upper limit S2 Lower limit S1 White E Brown Serial traffic B Green to MIDI 2 controller Surface sensor x Yellow L ele oO White 5 Yellow On Of x Green Push button lt Brown Sensor Alarm 12 V D
19. r pressure must be between 0 2 and 10 bars The water supply pipe must have a manual stop valve for stopping water supply to the unit if the unit is not used for a prolonged time Installation must follow local regulations It is recommended to use at least 18x16 mm steam generator s size 3 4 kW 9 5 kW and 22x20 mm steam generator s size 12 0 kW 14 kW copper pipe or a silicone tube of similar type when connecting the steam pipe The steam pipe diameter must be the same for the whole length The steam pipe must be tilted upwards or downwards from the steam generator to the steam room There MUST NOT be any water seals or water pockets The condensation water forming in the steam pipe must be allowed to drain freely to the steam room or back to the generator If a fragrance pump is connected to the generator the pipe must ALWAYS drain away from the steamer so that the chemicals cannot get into the tank Recommended maximum length for the steam pipe is 5 metres It is recommended to always use additional insulation for the steam pipe for both safety reasons and to prevent water condensation in the pipe Clearance from an uninsulated steam pipe to flammable material such as wood must be at least 10 mm WARNING Hot steam can cause burn injuries The electromagnetic valve designed for discharging water from the steam generator tank accessory Automatic drain valve is installed on the downpipe alternatively use manual flushing valve Conn
20. schutz Dieses Produkt darf am Ende seiner Lebens Dauer nicht ber den normalen Haushaltsabfall Entsorgt werden sondern muss an einem Sammelpunkt f r das Recycling von elektrischen und elektronischen Ger ten abgegeben werden Das Symbol auf dem produkt der Gebrauchsanleitung oder der Verpackung weist darauf hin Die Werkstoffe sind gem ihrer Kennzeichnung wiederverwertbar Mit der Wiederverwendung der stofflichen Verwertung oder anderen Formen der Verwertung von Altger ten leisten Sie einen wichtigen Beitrag zum Schutze unserer Umwelt Dieses Produkt soll ohne Steine und Specksteinmantel an dem Sammelpunkt f r Recycling zur ckgebracht werden Bitte erfragen Sie bei der Gemeindeverwaltung die zust ndige Entsorgungsstelle
21. so come out of the bottom of the control panel from a pre marked hole Control panel frame is pressed directly on it Detaching is done with tool that comes with the unit The frame has small holes on the edges 4 holes Push the locking pin lightly with the tool through the hole one at the time and pull the frame outwards at the same time The push button is filled with sealant therefore it may be installed in the steam room The push button may be installed through a wall acrylic walls or by making a suitable hole where the push button can be embedded and sealed with appropriate sealant Surface installation boxes may also be used if necessary they do not need to be tight because the actual push button is moisture resistant The sensor is installed at a height of 170 cm from the floor preferably on the wall opposite the door A retaining nut can be used with an acrylic wall A hole can be made onto a thicker wall and seal it with an appropriate sealant to prevent moisture from getting into the structures Insert the sensor in the case and tighten the cable using a clamping screw 55 mm Locking Locking E E O O LO oo Locking gt Locking 40 mm r 32 mm wall Sensor Sensors casing Locking screw User and installation manual HNS M2 14 Troubleshooting WARNING Steam generators may have several electric circuits Make sure that the device is completely dead before any troublesh
22. the steam generator for about 15 minutes Switch off the steam generator exactly the same way you normally do after bathing Wait at least 80 minutes and check if the bucket is filled with water If it is not filled there is a problem with the steam generator s electric connections or the power supply has been switched off on the wire from electrical cabinet directly to steam generator It is also possible that the exhaust valve is blocked or the circuit board is faulty TEST 2 Checking the thermostat sensor Wet a small towel with water and hang it on the sensor If the steam generator starts producing steam within 20 minutes the sensor works However it is placed in a wrong place or the temperature setting is too low If the steam production does not start use the troubleshooting chart to find the fault TEST 3 Checking the electromagnetic valve Stop the steam generator from the control panel If water still flows from the steam nozzles 10 minutes after the power has been switched off from the control panel there is dirt in the electromagnetic valve Remove the electromagnetic valve and clean it If the water flow stops within 10 minutes after the power has been switched off from the control panel the fault is in the electrics faulty connection or circuit board It is also possible that too much chalk has accumulated in the water tank See test 1 TEST 4 Checking the steam pipe using the safety valve or the overheating protector
23. tion This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and electronic devices The symbol on the product the instruction manual or the package refers to this The materials can be recycled according to the markings on them By reusing utilising the materials or by otherwise reusing old equipment you make an important contribution for the protection of our environment Please note that the product is returned to the recycling centre without any sauna rocks and soapstone cover Please contact the municipal administration with enquiries concerning the recycling place 17 Anvisningar f r milj skydd Denna produkt f r inte kastas med vanliga hush llssopor n r den inte l ngre anv nds Ist llet ska den levereras till en tervinningsplats f r elektriska och elektroniska apparater Symbolen p produkten handboken eller f rpackningen refererar till detta De olika materialen kan tervinnas enligt m rkningen p dem Genom att teranv nda nyttja materialen eller p annat s tt teranv nda utsliten utrustning bidrar du till att skydda v r milj Produkten returneras till tervinningscentralen utan bastusten och eventuell t ljstensmantel V nligen kontakta de kommunala myndigheterna f r att ta reda p var du hittar n rmaste tervinningsplats Hinweise zum Umwelt
24. to the wall so that the hot steam cannot burn anyone s feet The steam nozzles are aimed towards the floor When the nozzles are installed you must ensure to place them somewhere where nobody can accidentally touch them The steam temperature is 100 C and it can cause injuries on contact If children or people with impaired reflexes use the steam room the steam nozzle must be fitted with a protector that prevents people from being exposed to the hot steam shower Sensor The sensor is connected with the steam generator circuit board to connectors T1 and T2 which identify it automtically Sensor is installed at about 1 700 mm high preferably on the wall opposite the door It is recommended to seal the sensor installation hole with appropriate sealing material so that moisture cannot enter the wall structures The steam room thermometer is installed at such a height that it shows the same reading as the control panel Steamer connections Lid nut for decalcification Steam pipe Water connection Automated electromagnetic valve 7 plug HNS M2 Main switch Water draining manual Control panel cable or electric valve Power supply User and installation manual HNS M2 6 Water and steam pipe connections Connect the flexible water connection tube in the packaging to the water connection in the installation panel of the unit and to the cold water piping of the building The wate
25. ts the temperature in the steam room from raising above 50 C Sensor 0043210 See sensor installation on the next page Control panel Midi 2 and On Off button together You can use the On Off button with the control panel in order to start or stop the steam generator when the control panel has been installed elsewhere Press the On Off button for four seconds and the LED light on the push button lights up to show that the steam generator has started If you want to stop the steam generator using the On Off button before the time on the control panel has run out press for four seconds and teh LED light will switch off The control panel is used to set the temperature and time required Lighting controls Lights can also be controlled with the control panel light button which lights the LED indicator lights by the push button The steam generator connectors LC1 and LC2 on the circuit board are for lighting control Connect the light adapter connectors LC1 and LC2 to the corresponding connectors on th esteam generator circuit board See for more detailed instructions on the manual enclosed with the light adapter Accessory Light adapter 0043214 Error messages E1 The steam generator surface sensor does not sense any water filling time two minutes or the water tap is turned off when the stem generator is already running or something else is preventing the water from running into the steam generator Ensure that the steam generator gets wate
26. ular decalcification After flushing the steam generator will shut down to stand by mode until the next programme is initiated Safety valve installation The safety valve is installed on the steam pipe with using the provided 1 2 T connector A separate downpipe directly to a drain or to the floor is installed on the safety valve NOTE Safety valve s downpipe must not be connected to the steam generator s draining pipe or the steam pipe Use the provided sealing tape or similar sealing on the threads Image Safety valve and flushing valve Automatic drain valve installed Cleaning the steam room Rinse the seats and the floor with warm water after every use do not use a pressure washer Clean the seats regularly with mild detergent Use ethyl alcohol or dilutine Never use abrasives strongly alkaline detergents or solvents to clean the steam room seats and walls Contact the manufacturer if necessary It is important to clean the floor carefully all the way to the corners Use hot water a brush and floor detergent that removes dirt and grease The product s warranty will be void if the steam generator has been incorrectly installed or it has been used in a manner other than described in the user manual The warranty also expressly excludes operational faults if they are caused by hard water i e water with high levels of chalk or otherwise impure water The steam generator must be maintained as described in the user m

Download Pdf Manuals

image

Related Search

Related Contents

Montage- und Bedienungsanleitung  装置概要・マニュアル  n° 126 - Déc. 2010 - La Guilde Européenne du Raid  抜粋を見る(PDF:3.92MB) - 三井不動産レジデンシャルサービス  FANTEC P2700 - Billiger.de  Public ERIC: User Guide  Grupo de bombeo  Multiparamètres de laboratoire  nCompass 4.3i MC spec-order matrix  Panduit F9PD2-2M1 fiber optic cable  