Adam Equipment ACBplus SERIES

image

Contents

1. Shipping protection screw 4 Round cover around the screw e The scale comes with a plastic pan support and a stainless steel pan packed separately e Place the pan support in the receptacles on the top cover and fit the pan around it e Do not press with excessive force it could damage the load cell inside e Level the scale by adjusting the four feet The scale should be adjusted such that the bubble in the spirit level is in the centre of the level and the scale is supported by all four feet z e Attach the AC Adapter cable to the connector on the rear of the balance Plug the power supply module into the mains e Turn the power on by pressing the On Off switch e The unit will display the model number the software revision number and the input voltage for a while and then will count down performing a self test e When ready the display will show zero along with the weighing unit selected during the last operation Adam Equipment Company 2007 5 3 4 BATTERY CHARGING e The scales can be operated from the internal rechargeable battery or using the A C Adapter The battery life is approximately 24 hours depending on the usage of the backlight e The LED indicator on the left of the display will show when the battery needs to be charged To charge the battery plug in the AC adapter at the back of the scale and attach it to the main power supply The charging indicator at the left
2. 4 of maximum e Excessive weight on the pan when capacity when power is zeroing the scale turned on or when the e Improper calibration of the scale Zero key is pressed e Damaged load cell e Damaged Electronics Br5 Keyboard Error e Improper operation of the scale Er6 A D count is not correct e Load cell damaged when turning the scale on Electronics damaged Er 9 A D count is not stable e Initial instability during turning on when turning the scale on which will get adjusted automatically e There may be movement vibration or dirt on scale during turning on If an error message is shown repeat the procedure that caused the message such as turning the scale on calibration or any other functions If the error message is still shown contact your dealer for further support O Adam Equipment Company 2007 18 9 0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories contact your supplier or Adam Eguipment A partial list of such items is as follows e Power Supply Module e Dust Cover e Stainless Steel top Pan e Printers etc e Below Balance Hanger e Printer cable 10 0 SERVICE INFORMATION This manual covers the details of operation If you have a problem with the scale that is not directly addressed by this manual then contact your supplier for assistance In order to provide further assistance the supplier will need the following information which should be kept ready A Det
3. 5 3 SETTING THE PRINTING PARAMETERS When F3SH is displayed press Zero to view the first printing parameter 5 3 1 Selecting the communication port e The selected port for example 5 232 will be displayed e Press Mode to cycle through the other options The user can select S 232 or s Usb as the communication port Currently only RS 232 interface is available and the scale is set with this port only e Press Zero to view the next printing parameter 5 3 2 Setting the print mode e The current setting of the print mode is displayed e Press Mode to cycle through the other options e The following options are available P1 Prt The scale sends the accumulated weights to the communication port whenever the Print key is pressed P2 Con It will set the RS 232 interface to print the weights continuously and the accumulation function is disabled P3 AUT The weighing results will be sent to the communication port automatically whenever a weight is placed on the platform e Press Zero to view the next printing parameter O Adam Equipment Company 2007 14 5 3 3 Setting the baud rate e The current baud rate setting will be displayed e Press Mode to cycle through the other options e The following settings are available 600 1200 2400 4800 default value 9600 o o o o O e Press Zero to view the next printing parameter 5 3 4 Parity set
4. e The LCD normally shows the weight and the units of the weight selected previously Grams Carats Pounds etc See section 5 1 for details on Units O Adam Equipment Company 2007 2 2 0 SPECIFICATIONS 2 1 TECHNICAL SPECIFICATIONS ACBplus ACBplus ACBplus ACBpfus ACBplus ACBplus ACBp us 150 300 600 600H 1000 1500 3000 Maximum 150 g 300 g 600 g 600 g 1000 g 1500 g 3000 g Capacity Readability 0 005g 0 019 0 02 g 0 01 g 0 01 g 0 05 g 0 1 g Tare Range 150 g 300 g 600 g 600 g 1000 g 1500 g 3000 g Repeatability 0 005 g 0 01 g 0 02 g 0 01 g 0 01 g 0 05 g 0 1 g s d Linearity 0 01 g 0 02 g 0 04 g 0 02 g 0 02 g 0 1 g 0 2 g Pan 120 mm 4 77 124x144 mm 4 9 x 5 7 Draught Included as standard shield Units of g ct Lb 0Z d GN OZt dWt MM TL T TL C TL t t N g2 Measure 2 2 COMMON SPECIFICATIONS Interface RS 232 bi directional Stabilisation Time 2 Seconds typical Operating Temperature 0 C 40 C 32 F 104 F Battery Internal re chargeable Power supply external 9 VDC 800 mA Calibration Automatic External Display 16mm high 6 digits LCD With auto backlight and loading bar graph Scale Housing ABS Plastic with Stainless Steel platform Overall Dimensions wxdxh 195 x 240 x 70 mm 7 7 x 9 5 X 2 8 Net Weight 1 5 kg 3 3 Ib Adam Equipment Company 2007 3 3 0 I
5. top corner of the LCD will be on 3 5 DISPLAY 2H ADAM 0 00 656050009 3 6 INDICATORS The LCD has unique symbols to indicate the following 30 Zero Stable C Net Net weight A bar graph indicating the proportion HA of the scale capacity being used by the weight on the pan gt Low battery g ct Lb OZ d GN OZt dWt Symbols shown for the units MM TL T TL C TL t t N g2 Adam Eguipment Company 2007 6 3 7 KEY DESCRIPTIONS KEYS PRIMARY FUNCTION SECONDARY FUNCTION On Off To turn the scale On or Off Zero Sets the zero point for all A secondary function is of Enter subsequent weighing The display key for setting parameters or other shows zero functions Tare Tares the scale Stores the current Pressing Tare again will cancel weight in memory as a tare value the tare value subtracts the tare value from the weight and shows the results This is the net weight Enters the percent weighing When in percentage mode press function key to return to normal weighing mode Smpl Use this key to enter counting A secondary function allows the mode from the normal weighing user to return to normal weighing mode mode while in counting mode lt also clears the accumulated value from the memory when pressed during recalling the total Mode Pressing thi
6. 05 Battery recycling has become topical and the Waste Electrical and Electronic Equipment WEEE Regulations are set to impose targets for recycling Adam Equipment Company 2007 21 ADAM EQUIPMENT is an ISO 9001 2000 certified global organisation with more than 30 years experience in the production and sale of electronic weighing eguipment Products are sold through a world wide distributor network supported from our company locations in the UK USA SOUTH AFRICA and AUSTRALIA ADAM s products are predominantly designed for the Laboratory Educational Medical and Industrial Segments The product range is as follows Analytical and Precision Laboratory Balances Counting Scales for Industrial and Warehouse applications Digital Weighing Check weighing Scales High performance Platform Scales with extensive software features including parts counting percent weighing etc Crane scales for heavy duty industrial weighing Digital Electronic Scales for Medical use Retail Scales for Price computing Adam Equipment Co Ltd Adam Equipment Inc Adam Equipment S A Pty Ltd Adam Equipment S E ASIA Bond Avenue 26 Commerce Drive 7 Megawatt Road Pty Ltd Milton Keynes Danbury CT Spartan EXT 22 Kempton Park 2 71 Tacoma Circuit MK1 1SW 06810 Johannesburg Canning Vale Perth UK USA Republic of South Africa Western Australia Tel 44 0 1908 274545 Tel 1 203 790 4774 Tel 27 0 11 974 9745 Tel 61 0 8 6461 6
7. 05 Drams An ancient unit of weight Equals to 0 5645 d 1 16 of an ounce 06 Grains A basic weighing unit in the imperial 15 432 GN system Used to weigh gun powder 07 Ounce Troy ounce used for weighing gold 0 03216 OZt Troy silver and in pharmacy 08 Penny Pennyweight was the weight of a 0 6432 dwt weight silver penny in medieval England Equals to 1 20 of an Ounce Troy 09 Mommes A weighing unit used in Japan to 0 26667 MM weigh pearls 10 Taels Hk Hongkong Taels used to weigh coral 0 02675 TL T pearls etc 11 Taels S Singapore Taels 0 02646 TL C 12 Taels T Taiwan Taels 0 02675 TL t 13 Tical An Asian weighing unit 0 08576 t 14 Newtons Used to measure force 0 009808 N 15 Grams Grams with last digit suppressed 1 0 g2 5 2 SETTING OF THE BACKLIGHT e The backlight may be enabled or disabled by the user e If the backlight is disabled the battery life will be maximised e The following settings are available O Adam Equipment Company 2007 13 H AJ Sets the backlight to operate automatically when a weight is placed on the scale or a key is pressed H GF Sets the backlight to be off AM Sets he backlight to be on for full time e When F2 H is displayed press the Zero key to view the current setting for the backlight e Press Mode to scroll through other settings e Press Zero to store a particular setting e Use the Print key to leave a parameter unchanged
8. 236 Fax 44 0 1908 641339 Fax 1 203 792 3406 Fax 27 0 11 392 2587 Fax 61 0 8 9456 4462 E mail E mail E mail E mail sales adamequipment co uk sales adamequipment com sales adamequipment co za sales adamequipment au com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued However we are not responsible for misinterpretations which may result from the reading of this material The latest version of this publication can be found on our Website Visit us at www adamequipment com Adam Equipment Company 2007 22
9. ASCII code 4800 Baud 8 data bits No Parity Data Format for normal weighing operations parts counting or recalling of totals from memory will all be different GS 123 459 No 1 GS for Gross Weight NT for Net Weight and u for unit of weight This number increments every time a new value is stored in memory Total 123 45g The total value stored in memory lt If gt Includes 2 line feeds lt lf gt Adam Eguipment Company 2007 17 Input commands format The scale can be controlled with the following commands The commands must be sent in upper case letters i e T not t T5 345 lt cr gt lt if gt P lt cr gt lt lf gt Place a weight on the pan and then enter the pre set Tare value Prints the results to a PC or printer using the RS 232 interface lt also adds the value to the accumulation memory if the accumulation T lt cr gt lt lf gt Tares the scale to display the net weight This is the same as pressing Tare key Z lt cr gt lt lf gt Sets the zero point for all subsequent weighing Display shows zero function is not set to automatic 8 0 ERROR MESSAGES During the initial power on testing or during operation it is possible that the scale may show an error message The meaning of the error messages is described below ERROR CODE DESCRIPTION POSSIBLE CAUSES Er 4 Initial Zero is greater than Weight on the pan when turning on allowed
10. EHEZADAM Adam Eguipment ACBplus SERIES P N 4278 Rev C2 March 2007 Software Rev 2 11 Adam Eguipment Company 2007 Adam Eguipment Company 2007 CONTENTS 10 INTRODUCTION oto ao o E ua 2 20 SPECIFICATION Socio ai a 3 2 1 TECHNICAL SPECIPICATIONS opiece ieee ineeie eerie aeie aeee cidcid 3 2 2 COMMON SPECIFICATIONS ocu at asda adden es uae ian meats 3 20 INSTALLATION ce od a a ee ee cu CA O ccs o v 4 3 1 UNPACKING THE SCALE ooo oa 4 9 2 LOCATING THE SCALE sia k e a a e a a 4 3 3 SOE MING UPTIME SCALE s pap S DNU NSD DOD A DN bo d 5 3 4 BATTERY CHARGING resis AAA AA 6 345 DISPLAY aura Roi 6 3 05 INDICATORS ncen A AHA li 6 3 7 KEY DESCRIPTION Silla obed se late net ed na hase aut sa zao nt 7 40 OPERATION z ata dd adoos 8 4 1 ZEROING THE DISPLAY coter e E Eeee EE eE AE EESE EEEE 8 427 TAR St A o A A A Per arerre 8 4 3 WEIGHING o tt Arz 9 44 PERCENT WEIGHING usais A e eae eia 9 AS PARTS COUNTING ua ta 10 4 6 ACCUMULATION ccs cece es tt 10 9 0 PARAMETER Sure To 11 5 1 SELECTING THE UNITS tl italia 12 9 2 BETTINECOF THE BACKLIGHT tt eee e e 13 9 9 SETTING THE PRINTING PARAMETERS cinta 14 5 3 1 Selecting the communication port ioo0sosrorr r s ni 14 5 3 2 Setting the print mode oo senor eeeeeeeeneeeneee seen 14 9 4 3 Setting th Dad TALS siahli 15 9 3 46 Party SOUS A ha ara SAK SK SAK Rada sch 15 5 4 SETTING OF AUTO SWITCH OFF ccceceeeeeeeeeeeenneeeeeeeeeeet
11. NSTALLATION 3 1 UNPACKING THE SCALE Remove the scale from the packing carefully Inside the box you will find everything needed to start using the scale LN O DS AC adapter Pan support Stainless Steel Top Pan Draught shield Allen Key Weigh below hook This User Manual 3 2 LOCATING THE SCALE Om The scale should not be placed in a location that will reduce the accuracy Avoid extremes of temperature Do not place in direct sunlight or near air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Avoid unstable power sources Do not use near large users of electricity such as welding eguipment or large motors Do not place near vibrating machinery Avoid high humidity that might cause condensation Avoid direct contact with water Do not spray or immerse the balances in water Avoid air movement such as from fans or opening doors Do not place near open windows or air conditioning vents Keep the scale clean Do not stack material on the balances when they are not in use Adam Eguipment Company 2007 3 3 SETTING UP THE SCALE e Remove the shipping protection screw and round cover as shown below using the Allen key supplied in the box It is advisable to keep the shipping protection screw and the round cover along with the packing box for using during shipping to another location in future T lt
12. ails of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready reference Model name of the scale ACB plus Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place C Brief description of the problem Include any recent history of the unit For example Has it been working since it s delivered Has it been in contact with water Damaged from a fire Electrical Storms in the area Dropped on the floor etc Adam Equipment Company 2007 19 WARRANTY INFORMATION Adam Eguipment offers Limited Warranty Parts and Labour for the components failed due to defects in materials or workmanship Warranty starts from the date of delivery During the warranty period should any repairs be necessary the purchaser must inform its supplier or Adam Eguipment Company The company or its authorised Technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems However any freight involved in sending the faulty units or parts to the service centre should be borne
13. ass A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the eguipment is operated in a commercial environment The eguipment generates uses and can radiate radio freguency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this eguipment in a residential area is likely to cause harmful interference in which case the user will be reguired to correct the interference at his own expense Shielded interconnect cables must be employed with this eguipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Eguipment could void the user s authority to operate the eguipment WEEE COMPLIANCE Sealed Lead Acid z Battery Va Must be recycled PB Properly Any Electrical or Electronic Equipment EEE component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002 95 EEC must be recycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Landfill England and Wales Regulations 2002 and Hazardous Waste Regulations 20
14. by the purchaser The warranty will cease to operate if the eguipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Eguipment This warranty does not cover eguipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the reguirements and recommendations as given in this User Manual Repairs carried out under the warranty does not extend the warranty period Components removed during the warranty repairs become the company property The statutory right of the purchaser is not affected by this warranty The terms of this warranty is governed by the UK law For complete details on Warranty Information see the terms and conditions of sale available on our web site Adam Eguipment Company 2007 20 CE Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 89 336 EEC Low Voltage Directive 73 23 EEC Adam Eguipment Co Ltd Bond Avenue Denbigh East Milton Keynes MK1 1SW United Kingdom FCC COMPLIANCE This eguipment has been tested and found to comply with the limits for a Cl
15. d back to 10 Press Smpl again when the number matches the number of parts used for the sample As more weight is added the display will show the number of parts PCS with respect to the chosen sample size Press Mode to display unit weight W P total weight g or the count PCS The total and the unit weight are shown in the current units Press Smpl to return to normal weighing 4 6 ACCUMULATION When the scale is set for automatic accumulation the weight will be added to the memory when the scale becomes stable The scale must return to zero before another weight is added O Adam Equipment Company 2007 10 e When the scale is set to manual accumulation See the Parameter Section the weight displayed will be stored in memory when the Print key is pressed and the weight is stable e The display will show ACC T followed by the total value in the memory for 2 seconds before returning to displaying the weight of the item on the scale e The weight will be output to a printer or PC e Remove the weight allowing the scale to return to zero and put a second weight on e Press Print the display will show ACC 2 followed by the new total in the memory for 2 seconds before returning to displaying the weight of the item on the scale e Continue until all weights have been added e To view the totals in memory press the Print key when the scale is at zero The display will show ACC xx where xx is the t
16. ee section 5 4 tECH Pressing Zero will allow the user to enter the technical parameters setting mode It is recommended not to proceed with the settings of these parameters as those are set up at the factory 5 1 SELECTING THE UNITS When FIL Unt is displayed press the Zero key to view the current settings of each unit Press Zero again to cycle through the other units along with their current settings For example if oF is displayed with the weighing unit Carats the user will not be able to use this unit while weighing Press Mode to change the settings of a particular unit For example to enable the weighing unit Carats change the setting to on by pressing Mode now O Adam Equipment Company 2007 12 e Use the Print key to leave a parameter unchanged e While weighing a sample the display will show the weight and the units of weight currently in use To view the weight in other units which are enabled press Mode e The following table shows different units which are available to the user and the conversion factors for each SL Name of Description Conversion Display No the Units Factor Symbol 01 Grams A standard metric unit 1 0 g 02 Carats Used for weighing jewellery and 5 0 ct gems etc 03 Pounds Standard weighing unit in UK USA 0 002205 Lb 04 Ounce Avoirdupois ounce 0 03528 OZ 16 ounces make a pound
17. eeeenaaees 15 55 TECHNICAL PARAMETERS ere e en e terrre steen eeste neren steres 16 6 0 CALIBRATION cardinal dat di dis dni 16 7 0 COMMUNICATION WITH A COMPUTER PRINTER ceeeeeeeeeeeees 17 80 ERROR MESSAGES oO 18 9 0 REPLACEMENT PARTS AND ACCESSORIES o 19 10 0 SERVICEINFORMATION adorada dis oudlase za 19 Adam Eguipment Company 2007 1 0 INTRODUCTION e The ACBplus series of scales are simple and easy to use e The scales can be operated with an A C adapter or using an internal rechargeable battery e The weighing process is fast and accurate making it suitable for the general purpose weighing applications parts counting percentage weighing functions etc e There are 7 models in this series with capacities ranging from 150 grams to 3 kilograms e All models include automatic zero tracking automatic tare accumulation facility that allows the weight to be stored and recalled as an accumulated total and bi directional RS 232 interface for communicating with a PC or printer e All have stainless steel weighing platforms on an ABS plastic base assembly e Keypads are sealed with colour coded membrane switches The scales have a weigh below facility supplied as standrad The displays are large easy to read liquid crystal type displays LCD It is provided with a backlight and also a bar graph at the bottom to display the weight of the item on the pan with respect to the capacity of the scale
18. ing is selected 4 4 PERCENT WEIGHING e The scale will allow a sample weight to be shown as 100 Then any other weight placed on the scale will be displayed as a percentage of the original sample e For example is 350g is placed on the scale and the key is pressed the display will show 100 00 Removing the 350g weight and place a 300g weight on the scale The display will show 85 71 as 300g is 85 71 of 350g Note The scale may jump by large numbers unexpectedly if small weights are used to set the 100 level For example if only 23 5g is on a scale with 0 5g increments and the scale is set to 100 the display will show 100 00 However a small change of weight will cause the display to jump to Adam Eguipment Company 2007 9 102 13 as one scale division 0 5g increase to 24 0g will be eguivalent to a 2 13 increase Pressing the key again will return the scale to normal weighing 4 5 PARTS COUNTING When the scale is in normal weighing mode pressing the Smpl key will start the parts counting function Before beginning tare the weight of any container that will be used leaving the empty container on the scale Place the number of samples on the scale The number should match the options for parts counting 10 20 50 100 or 200 pieces Press the Smpl key The scale will initially show SP 10 asking for a sample size of 10 parts Press Mode to cycle through the options 10 20 50 100 200 an
19. ll show unLoA Remove all weights from the pan e Wait for the stability indicator to be on and then press Zero e The display will then show the first calibration weight request e Press Mode to scroll through the other calibration weights e Press Zero to select calibration weight The display will show LoAd Adam Equipment Company 2007 16 e Place this weight on the platform and press Zero when the stability indicator will be on to show the value is stable e If the calibration is complete the scale will show PASS and will return to normal weighing counting back to zero Remove the calibration weight at this stage e f the wrong calibration weight is used the scale will show FAL H when the weight is higher or FAL L when the weight is lower Repeat the process using the correct calibration weight Calibration weights Model ACBp us ACBplus ACBp us ACBplus ACBpfus ACBp us ACBplus 150 300 600 600H 1000 1500 3000 Weight 1 509 100g 2009 200g 500g 500g 10009 Weight 2 100g 200g 400g 4009 10009 10009 20009 Weight 3 1509 3009 600g 600g 1500g 3000g 7 0 COMMUNICATION WITH A COMPUTER PRINTER The ACBplus scales come with a bi directional RS 232 interface The standard Interface parameters are Connection details are Connector 9 pin d subminiature socket Pin3 Output Pin 2 Input Pino Signal Ground RS 232 output of weighing data
20. m the displayed value leaving zero on the display The NET symbol will be on at the right top corner to indicate that the weight displayed is the net weight e Asthe product is added only the net weight will be shown e The scale could be tared a second time if another type of product was to be added to the first one Again only the weight that is added after taring will be displayed e When the container is removed a negative value will be shown If the scale was tared just before removing the O Adam Equipment Company 2007 8 container this value is the gross weight of the container plus all products those were removed e The zero indicator will also be on because the platform is back to the same condition as it was when the Zero key was last pressed e To cancel the tare value press Tare again 4 3 WEIGHING e After zeroing the display and taring the container place the sample in the container to determine the weight of the sample The weight will also be displayed through a bar graph at the bottom of the LCD e The display will show the weight and the units of weight currently in use The stable indicator will be on To change the weighing units press Mode to cycle through the options of units those are enabled See the Parameter section to enable or disable the weighing units e The accumulated value in the memory will be cleared when a new weighing unit or during recalling the memory weighing or parts count
21. otal number of readings and the total weight before returning to zero e The total will also be printed via the RS 232 interface e To clear the memory press Smpl immediately after pressing Print 5 0 PARAMETERS e The scale has 5 parameters that can be chosen by the user to set the scale e To set the parameters press the Mode key during self checking test e After a few seconds the display will show the first function FL UNT O Adam Equipment Company 2007 11 To view the current settings of each parameter press the Zero key Press the Zero key again to cycle through the other parameters along with their current settings For example if oF is displayed with the weighing unit Pounds the user will not be able to use this unit while weighing a sample Press Mode to change the settings of a particular parameter For example to enable the weighing unit pounds change the setting to on by pressing Mode now Use the Print key to leave a parameter unchanged The following parameters are available FUNCTION DESCRIPTION FLUNT Sets the units to be used See section 5 1 g ct Lb 0Z d GN OZt dWt MM TL T TL C TL t t N 92 PA Sets the backlight See section 5 2 H on backlight always on E_OFF backlight always off EAU backlight automatically turns on when a key is pressed F3SE Sets the print parameters See section 5 3 F4 OFF Sets the auto switch off parameter S
22. s key will cycle through Displays the unit weight total the weighing units which are weight and the count when in the enabled It also scrolls through the parts counting mode options during setting up a parameter Print To print the results to a PC or Secondary function is to return to printer using RS 232 A USB interface will be available shortly It also adds the value to the accumulated memory if the accumulation function is not set to automatic normal operation when the scale is in a parameter setting mode Adam Eguipment Company 2007 7 4 0 OPERATION 4 1 ZEROING THE DISPLAY e Press the Zero key when the platform is empty e Zero key may be pressed at any time to set the zero point from which all other weighing and counting is measured e When the zero point is obtained the zero indicator will be on in the left bottom corner of the LCD e The scale has an automatic re zeroing function to account for minor drifting or accumulation of material on the platform However you may need to press the Zero key to re zero the scale if small amounts of weight are shown when the platform is empty 4 2 TARING e Zero the scale by pressing the Zero key if necessary e The zero indicator will be on e Place a container on the platform a value for its weight will be displayed e Press the Tare key to tare the scale The weight that was displayed is stored as the tare value It is subtracted fro
23. tings e The current Parity setting will be displayed e Press Mode to cycle through the other options e The following settings are available 7E 1 7 data bits even parity 701 7 data bits odd parity e Press Zero the display will go back showing F3 SE e Press Mode to go to the next parameter which is F4 oF 5 4 SETTING OF AUTO SWITCH OFF e The Auto switch off time may be set up by the user e When F4 OFP is displayed press the Zero key to view the current setting Adam Equipment Company 2007 15 e Press Mode to scroll through other settings 0 5 10 20 and 30 minutes e Press Zero to store a particular setting e Use the Print key to leave a parameter unchanged 5 5 TECHNICAL PARAMETERS e Next parameter is tECH This allows the user to enter the Technical Parameters section Note It is recommended not to proceed with the settings of the Technical Parameters which are set up at the factory and are often referred to as Service Parameters Check the Service Manuals for more details e Press Print to return to weighing The scale will run the self test before displaying the zero along with the last selected unit 6 0 CALIBRATION e This parameter allows the user to calibrate the scale any time during the operation e Switch the scale off and then on it again by pressing On Off During the self test press Smpl and Print together e Display wi