Home
Manual - Termoventiler AB
Contents
1. 2 Settings and menu display Auto 3 C Open the lower cover for access to the navigation buttons lt or gt You can now press these buttons to show the row with various operational modes Move the cursor to the desired operational mode and press OK to set the mode See below for explanation of the various modes What is displayed and settings options In order to browse the values use the Escape button o gt All set values apart from Timer can also be set from the Control Panel When only using room sensor mode r or room sensor outdoor sensor mode ro you can set the desired room temperature set point for Day Night Moon or Timer The display shows the set point the room temperature and outdoor temperature if appropriate When using room sensor with outdoor sensor as the priority mode or the set room temperature acts as a maximum limit It should then be set slightly above the desired room temperature The display shows the maximum value the room temperature and outdoor temperature When only using an outdoor sensor mode o0 no normal temperature settings can be made for the room sensor If you want to reduce you can set it using the Night Moon temperature It is however still possible to select operational modes apart from Timer and you can see the actual indoor and outdoor temperature All curve settings are made from the Control Panel When using only the supply sensor mode C you can set the de
2. d up to 45 days using or Press OK to approve The icon starts to flash Browse using gto see the set point and remaining time 7 a The room sensor reverts to the previous operational mode after having been in Timer mode If you want to stop the Timer function I8 before the end of the period change to the desired operational mode using lt or gt and then OK to save 2 5 Auto mode In this mode EC Home automatically switches between Day and Night temperatures according to the time settings on the Control Panel The following temperature settings apply when the Auto mode is activated Select the temperature to be changed using A single press on or will make the set point to be changed read start to flash and this setting can be changed using or The value is saved when you press OK The room sensor automatically reverts to the main menu after a couple of seconds NOTE All time settings are made from menu 4 on the Control Panel You will find this described in the full manual for EC Home 4 3 Special functions 3 1 Locking buttons Used to prevent changes to settings e g in a child s room or public area In order to activate the lock first press and hold the Escape button while at the same time pressing the Edit button e T The icon will be shown on the display Repeat the procedure to unlock the buttons 3 2 nformation This function allows you to see all act
3. OK to accept Yes should now be displayed and the new value is saved in the memory If you need to remove a calibration press on or when you are in this menu to erase the cali brated value 07 Cir Factory settings Press and hold the OK button for 3 seconds to reset Settable temperatures and parameters are returned to the factory set tings NOTE Ensure that you have everything you need to be able to start again before you use this function O8 Program version O9 End Exit the Tools menu Press OK to exit the menu and return to the operational mode 5 Troubleshooting and Solutions Room sensor does not start Battery problems Check that the plastic tab has been removed from the batteries Check that the batteries have been inserted correctly Check that the batteries are OK Battery voltage too low icon flashes Battery Change the batteries The room sensor appears to work correctly but the heating does not work Check that the room sensor icon is lit steadily on the Control Panel display lf the icon is not lit Check the aerial connection lf the above is OK try to change the batteries in the room sensor Contact your electrician RF communication does not work Check the following items The aerial must not be placed nearer than 50 cm to other electrical or wireless units e g GSM or WIFI Aerial should not be placed on metallic objects or too close t
4. THERMOMATIC EC HOME Wireless room sensor Installation and User Manual NOTE This manual is primarily intended for installation and use of the wireless room sensor for Thermomatic EC Home Other installations and functions are explained in the complete manual for EC Home Locating the aerial Aerials should not be Aerials should not be Aerials should not be placed on metallic objects located to close ot other located too close to or on metal pipes wireless units or power the room unit during cables initiation Preparation 3 Fit the flow sensor 7 Turn off the pump 4 Plug in the power 2 Fit the motor to Supply the mixing valve Activation of radio communication O v x4 V x8 710 6 Click to start radio communication amp Close the cover and hold the 9 INI will light for some 10 Enter the motors direction button depressed in order to start seconds Ready of rotation menu 7 1 the initiation rr Ca E ECHOME_WL_Manual_E indd I e r mi ove n Ci l r AB 821505 m 446 0 321 261 80 info termoventiler se www termoventiler se Installation and locating the room sensor NOTE We recommend that you install the room sensor using the enclosed screws and plugs as incorrect positioning of the sensor may jeopardize heating comfort 1 Presentation This room sens
5. o metal pipes The room sensor appears to work correctly but the temperature in the room does not agree with my thermometer Try to calibrate the room sensor see Tools menu 04 Contact your electrician retailer to check whether control needs adjustment adaptation to your heat ing system 6 Technical specifications surrounding environment Working temperature 0 C 40 C Transport and storage temperature 10 C to 50 C Electrical safety class IP30 Range Approx 30 m in buildings Precision 0 1 C Settings range Day Night Moon Timer 5 C 30 C in 0 1 C steps Supply temperature 5 C 90 C in 1 C steps Power supply Battery lifetime 2 years 2 AAA LRO3 1 5V Alkaline or equivalent sensor type NTC 10 kOhm at 25 C Radio frequency 868 MHz lt 10mW The room sensor has been designed in accordance with the following standards or other standardi sing documentation EN 60730 1 2003 EN 61000 6 1 2002 EN 61000 6 3 2004 EN 61000 4 2 2001 EN300220 1 2 EN301489 1 3 R amp TTE 1999 5 EC Low voltage 2006 95 CE EMC 2004 108 CE CE
6. or is designed for use with Thermomatic EC Home ver 121001 or later 1 1 The function of the buttons Move browse to the left lt Anti frost function Holiday Timer Booster function Keeps settings during battery replacement 2 x AAA batteries give up to 2 years operation Move browse to the right gt gt C Escape a Decrease Increase Edit e Approve OK Status LED S lO 1 2 Display amp LED S Green flashing for OK Approval required 1 Operational mode active mode displayed 2 Displays selected control setting or active tool menu r Room sensor ro Room sensor with outdoor sensor or Outdoor sensor with room sensor o Outdoor sensor C Supply sensor 3 The icons are displayed when the Tools menu is active and at start up 4 The icon that lights shows which relevant temperatures is cO CO nN OQ O Battery icon Flashes when the battery voltage is low External contact remote control activated in CC Button lock indicator RF indicator Lights during transmission shown on the display Room f gor outdoor i l S When displaying the set point none of the icons light ponas Auto Auto SZA Set or read temperature and remaining time if Timer setting is on i T I m J TW Cp at J I J J 8 O
7. sired supply temperature You can also see the relevant room temperature Potential reduction of the supply temperature can be set using the Night Moon temperature 2 1 Day temperature R In this mode the set Day temperature is kept all of the time The factory settings are 20 C for r and ro 30 C for or and 60 for C By pressing or the temperature will begin to flash and the setting may be changed Save by pressing OK 2 2 Night Moon temperature C In this mode the set Night Moon temperature is kept all of the time The factory settings are 16 C for r and ro O C for or o and C By pressing or the temperature will begin to flash and the setting may be changed Save by pressing OK 2 3 Anti frost mode This is used if you want to shut down the heating but still have a minimum permitted supply tempera ture to prevent the system free zing e g while you are on holiday The anti frost temperature is fixed at 10 C 2 4 Timer mode Get started guide for settings gt oC 1h 45d The timer mode means that you can change the temperature at certain times This is not available for modes o or C You can first set the temperature using or Press OK to start the function preset value is 24 C The next step is to set how many hours H if less than 24 hours the timer will be active and then the number of days
8. ual temperatures and the set values by pressing repeatedly on the Escape button w You can also see time remaining when the Timer mode is activated 4 Tools menu The room sensor has a tools menu for other settings In order to access this menu press and hold the Edit button e for 3 sec The menu is activated and the first sub menu is displayed nn uu TE N i The first menu displayed is the initiation mode You can select the parameters to be changed using the navigation buttons lt or gt When you have selected a parameter you can edit the value using the OK button or begin to change the value using or The value flashes for a few seconds or until OK is pressed In order to save the change you must press OK In order to leave the tools menu browse to End and press OK 4 1 Basic values and other settings OO INI Radio configuration sends the radio link signal to pair the room sensor with the Control Panel aerial 04 HG Room sensor calibration NOTE The heat inertia of a house means that it may take as long as 24 hours before the right tempera ture is achieved Place a thermometer by the side of the room sensor around 1 5 m above the floor and read off the temperature after one hour When you enter the calibration menu no is displayed when no calibration has taken place Use the or button to set the temperature to the same as shown on the thermometer Then press