1. Pump runs but does not deliver water e Pump is air locked start and stop several times by plugging and unplugging cord check for clogged vent hole in Pump runs but ee PESEE PEO i e Vertical pumping distance is too high or pipe size is too small reduce vertical distance or increase the pipe size delivers only a small e Inlet holes in pump base are clogged remove pump and clean the openings amount of water e Impeller or volute openings are fully or partially clogged remove pump and clean e Pump impeller is partially clogged with debris causing motor to run slow and overload remove pump and clean e Pump impeller is partially clogged with debris causing motor to run slow and overload remove pump and clean e Motor stator may be defective e Fuse size or circuit breaker may be too small must be 15 amps pump starts e Impeller or volute opening are fully or partially clogged remove pump and clean Fuse blows or circuit breaker trips when e Inlet holes in pump base are clogged remove pump and clean the openings e Pump impeller is partially clogged with debris causing motor to run slow and overload remove pump and clean e Motor stator may be defective Motor runs for a short time then stops Limited Warranty Return warranty pumps to e This product is warranted against any mechanical or material de fects for a period of two years from the date of purchase e This warranty does not cover accidental damage to t
2. TM13500 TM17500 18 17 17 01 stator ceo r oil Seal Cover F620 01 12 13 06 14 07 15 16 43 14 07 15 16 SUS Strainer for TM9500 TM13500 1 FCD45 for TM17500 Upper Bearing tC Lower Bearing Tt OilSea NBR __ 1 ShaftSleeve SUS 1 PowerCord tC 09 10 m s Troubleshooting md ge o 141 Possible Causes Line circuit breaker is off or fuse is burned or loose Water level in sump has not reached turn on level as indicated in installation drawing on the carton Pump hums e Pump cord is not making contact in receptacle Float optional is stuck It should operate freely in basin If all of the above are OK and then the motor should operate Check valve optional is installed backwards not included with pump arrow on valve should point in direction of flow Discharge shut off valve if used may be closed e Impeller or volute openings are fully or partially clogged remove pump and clean e Pump is air locked start and stop several times by plugging and unplugging cord check for clogged vent hole in pump case e Inlet holes in pump base are clogged remove pump and clean the openings e Vertical pumping distance is too high or the pipe size is too small reduce vertical distance or increase the pipe size fittings
3. sharp edges WARNING The power cable must be replaced by qualified personnel only Grounding The plug of the power cable has a double grounding contact so that grounding can be performed by WARNING simply inserting the plug Overload Protection EasyPro pumps have a built in thermal protection switch The pump stops if an overload condition occurs The motor restarts automatically after it has cooled down Prior to Operation Check the following points upon receipt of your pump Is the pump exactly what you ordered Check nameplate Has any damage occurred during shipment Are any bolts or nuts loose Have all necessary accessories been supplied We recommend that you keep a spare pump on hand in case of emergencies Keep this instruction manual in a place for future reference Specifications Model HP Volts Max Amps Weight Dimensions Max Head Max Flow TM9500 1 115 10 9 52 Ibs 12 X75 X195 31 9500 GPH TM13500 1 5 115 12 58 Ibs 12 x 7 5 x 20 33 13500 GPH TM17500 2 230 10 70 Ibs 12 6 x 8 6 x 22 5 40 17500 GPH Pump Performance Chart Feet of Head 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 17000 20 40 60 80 100 120 140 160 180 200 220 m Best efficiency Installation Symbol and Meaning DANGER e Keep the pump equipment out of the reach of children Warns that failure to DANGER follow directions could cause serious risk injury to individuals or obj
4. TM9500 e TM13500 e TM17500 High Quality TM Series Waterfall Pumps Instructions for Operation Safety Warranty Thank you for purchasing the TM series waterfall pump This instruction manual explains the product operations and gives important precautions regarding its safe use In order to use the product to maximum benefit be sure to read the instructions thoroughly and follow them carefully To avoid accident do not use the pump in any way other than as described in this instruction manual especially when you see WARNING After reading this instruction manual keep it nearby as a reference in case questions arise during use lf this instruction manual should become lost or damaged ask your nearest dealer or representative for another copy Safety amp Electrical Connections WARNING Verify that the voltage and frequency of the electric pump shown on the nameplate correspond to those available on the mains WARNIN The installer must make sure that the electric system is grounded in accordance with local ordinances The plug and connections should be protected from water rain Before using the pump always inspect it visually especially power cable and plug Do not use the pump if it is damaged lf the pump is damaged have it inspected by a qualified service center only Make sure that electric connections are protected from all water and moisture Protect the plug and the power cable from heat oil or
5. damage cuts Each year we receive numerous pumps back that simply have a small stone lodged in the impellar are plugged from lack of cleaning or do not work due to low voltage caused by an overloaded circuit These are not warranty items Please take the time to verify your problem is actually a defective pump before returning EasyPro will pay postage to return pump to you provided it is a warranty issue If you send a pump in for warranty and it checks out fine you will also be responsible for the cost of return postage 800 448 3873 Grant Michigan www EasyProPondProducts com e info EasyProPondProducts com 12 11
6. ects WARNING This sign warns the operator that the failure to follow an instruction may WARNING damage the pump and or the system Limitations This series of pumps are suitable to pump rain water and also can be used both for permanent and temporary installa tion The pump can be placed in a sump pit then can pump dirty water containing suspended solid particles up to 1 2 diameter A WARNING The pump cannot be used for sea water and flammable corrosive explosive or dangerous liquids WARNING Installation WARNING Do not work on pump until power is unplugged WARNING Do not cut off ground pin or use an adapter fitting Do not use an extension cord Must be used on a GFCI protected outlet Do install the strainer prior to using if you want to let the pump run as a sump pump The pump power cord should be connected to a separately fused grounded line with a minimum capacity of 15 amps It can be connected to non fuse breaker at the recommended amps Never touch the pump when it is plugged in s Before installing or servicing this pump be certain pump power source is disconnected Contact a qualified li censed electrician for disconnecting electrical service prior to pump removal Installation and electrical wiring must adhere to state and local codes and must be completed before priming pump Check appropriate community agencies or contact local electrical and pump professionals Call an electrician when in d
7. he product due to abuse or negligence by the consumer EasyPro e An RMA number must be obtained by calling EasyPro Pond Prod Pond Products ucts at 800 448 3873 and be included on package before returning 4385 East 110th for warranty issues Grant MI 49327 Return warranty items to B o mcud EasyPro Pond Products 4385 East 110th Grant MI 49327 Co ee eee RMA number origi nal receipt return address and phone e Inthe event of a warranty claim please return the pump postage number in package prepaid with the original receipt for repair or exchange No warranty claims will be honored without the original receipt Be sure to include RMA number original receipt name return ad dress and phone number in package e The manufacturer or supplier shall not be held liable for any damages caused by defective components or materials of this pump or for loss incurred because of the interruption of service or any consequential incidental damages and expenses arising from the produc tion sale use or misuse of this product e The manufacturer or supplier shall not be held liable for any loss of fish plants or any other livestock as a result of any failure or defect of this product e lf you experience a failure of your pump please check the following before returning to us 1 Remove filter housing clean and inspect impellar and surrounding chamber reassemble and test pump 2 Verify electrical supply 3 Check power cord for
8. oubt Pump should be connected to a separate 15 amp circuit breaker or 15 amp fuse block Note that plugging into existing outlets may cause low voltage at motor causing blown fuses tripping of motor overload or burned out motor A permanent ground connection from pump to the grounding bar at the service panel is mandatory For maximum safety connect pump to a circuit equipped with a Ground Fault Circuit Interrupter device when you position the pump s grounding wire Voltage of power supply must match the voltage of the pump WARNING Must be vented in accordance with local plumbing codes EasyPro pumps are not designed for and CANNOT be installed in locations classified as hazardous WARNING WARNING The following may cause severe damage to pump and will void warranty Using an extension cord Cutting off the ground pin or using an adapter fitting Working on pump or switch while plugged in Removing motor housing unscrewing impeller or otherwise removing impeller seal Pumping chemicals or corrosive liquids Pumping gasoline or other flammable liquids Piping Plastic PVC pipe drain hose galvanized steel or copper pipe may all be used All piping must be clean and free of all foreign matter to prevent clogging Use thread compound on all threaded joints unless specified otherwise Be sure to seal the thread connection with tape seal when you are using the pipe fitting to connect the flange WARNING Replacement Parts TM9500