1. ID code 123 will become 3 and ID code 12 will be rejected 32 TR515 User s Manual Default value for this setting is 1 Number of Characters group 1 register 8BH Set Possible error codes 04 07 Command C8B NN Reply A Get Possible error codes 04 07 Command B8B Reply ANNcc NN the length of the position of code that will be extracted in Hex form range 01H 25H cc checksum Number of Characters together with From Character setting allows you to extract and store into the database a portion of code from the User UD Card instead of the entire ID Card code This way you can adjust the format of the data generated by the TR515 to the requirements of some specific PC software You can also use this Setting to hide a certain portion of the ID Cards code This is useful for a simple access control function implementation Number of Characters defines the length of the portion of code that will be extracted from the ID code starting from the From Character position The valid value range for this setting is from 1 to 37 Actual number of extracted characters can be smaller than that defined by the Number of Characters Setting This happens when From Character Number of characters 1 gt length of ID code Examples If From Character 2 and Number of Characters 3 then ID code 12345 will produce 234 and ID code 123 will result in 23 only Default v
2. PINS PIN7 PIN PINS WAS 1467 LENGH 2000 mm WIRE 8P8C AWG 26 WAS 1467 Rj 11 8P8C PIN COLOR WIRE 1 GRAY CUT 2 ORANGE CUT 3 BLACK CUT 4 RED CUT 5 GREEN 5 6 YELLOW CUT 7 BLUE 7 8 BROWN CUT CUT Cut wire 42 TR515 User s Manual 3 WAS 1498 For TR515EX TO PC siden PIN1 PINI PIN8 PINS WAS 1498 LENGH 1800 mm CAT 5 4PAIR 24AWG UTP WAS 1498 Side A COLOR Side B L WHITE 3 2 ORANGE 6 3 WHITE 1 4 BLUE 4 5 WHITE 5 6 GREEN 2 7 WHITE 7 8 BROWN 8 1 2 and 3 6 must share the same twisted pair 4 WAS 1499 For TR515EX TO HUB PINS PINS WAS 1499 LENGH 1800 mm CAT 5 4PAIR 24AWG UTP WAS 1499 Side A COLOR Side B 1 WHITE 1 2 ORANGE 2 3 WHITE 3 4 BLUE 4 5 WHITE 5 6 GREEN 6 7 WHITE 7 8 BROWN 8 1 2 and 3 6 must share the same twisted pair 43 TR515 User s Manual Appendix D Specifications Display Magnetic card reader Barcode reader RFID card reader RFID reading range ISO card sized tag HID reader only reads Card number Mifare reader Database capacity Supported interfaces Wireless Communication Communications parameters Bell control relay Physical dimensions Installation Power supply Power supply from PoE TR515Ex 20 only Operating temperature range Operating humidity 4 x 7 segment Blue Light LED
3. ISO Track 2 75 bpi Visible or IR numerical Code39 125KHz ASK 64bits Manchester encoding 8cm Wiegand 26 30 34 35 37 Reading U ID data App 8168 records 4084 records Ethernet Wireless RS232 RS485 315 16 433 92Mhz or 433 92 434 33Mhz 19200 8 n 1 1A 12V max 185 L x 110 W x 51 H mm Wall mount or desktop DC 9V 500mA Fully IEEE 802 3af compliant 0 55 C 5 95 Requires a special adaptor CON485 purchased separately If ID code is Track 1 or J IS Il code database capacity is 4084 records Per Also accept power from auxiliary sources such as 12V ac adapter when PoE network power is unavailable Appendix E Ordering Information Ethernet Interface TR515EM Time Recorder with Magnetic Card Reader TR515ER Time Recorder with RFID Card Reader TR515EB Time Recorder with Barcode Card Reader visible TR515EF Time Recorder with Barcode Card Reader infrared TR515EH Time Recorder with HID Card Reader TR515EMF Time Recorder with Mifare Card Reader Wireless Interface TR515WM Time Recorder with Magnetic Card Reader TR515WR Time Recorder with RFID Card Reader TR515WB Time Recorder with Barcode Card Reader visible TR515 User s Manual TR515WF Time Recorder with Barcode Card Reader infrared TR515WH Time Recorder with HID Card Reader TR515WMF Time Recorder with Mifare Card Reader RS 232 485 Interface TR515SM Time Recorder with Magnetic Card Reader TR515SR Ti
4. A may contain some data as shown on the Figure above Reply packets with the reply code N always contain a 2 digit error code that can be used to analyze the source of a problem The checksum is an 8 bit sum of all characters between the STX and CR represented as a 2 character HEX string For an example packet below the checksum is calculated as follows The data part of the packet is AIXYZ The sum of these character codes is 41H 31H 58H 59H 5AH 17DH Eight least significant bits contain 7DH The string representation of this value is 7D i e 2 ASCII characters 7 and D STX A 1 X Y Z 7 D CR 02H 41H 31H 58H 59H 5AH 37H 44H 0DH Packet portion the checksum is calculated on Checksum TR515 User s Manual Table below lists all possible error codes 04 Illegal invalid command command code or data is wrong 06 Record number is out of range requested record doesn t exist 07 Command failed hardware problem or invalid internal data 08 Log data memory is full this message reply in Extended mode 09 Access has been denied terminal is not in Extended mode Summarized below are all supported commands Command characters are found in the CC column their corresponding ASCII codes in Hex CS lists commands that require the checksum in the command packet C or reply packet R Error code column lists
5. 1 8 above to seta New Device Move the cursor to 000 default to set the IP address of the New Device Cursor must be at 000 default position before setting the IP Address otherwise the other machine s IP address will be changed Pe Settings Ring Table Time Scheduler Device List pean DE R510 Firmware Version v1 6 Com Port Select DS100Y2 x pl192 168 100 234 001 DOOR Add Delete Set Mt setTime Display Reset e Double click 000 default to complete the connection to New Device 51 TR515 User s Manual FT TRS15 Tool 1 2R9 000 Default MEE Settings Ring Table Time Scheduler Device List pan TR510 Firmware Version V1 6 Com Port Select D5100v2 z 001 DOOR rl 92 168 100 234 Add Delete SetM setTime Display Reset f Click Add to seta New ID ET TRS15 Tool 1 2R9 000 Default Mme Settings Ring Table Time Scheduler Device List Machine 2 001 DOOR 002 Machine 2 TR510 Firmware Version V1 6 Com Port Select DS100V2 Ho 0 0 0 Set M SetTime Display Reset g Click Set M to assign the ID to new device Assign new ID x Select ID address download to TR515 Joo DOOR 001 DOOR 002 Machine 2 52 TR515 User s Manual h ID setting of new device is completed 53
6. Real time Log out from Extended mode o 6FH Possible error codes none Command Reply A This command logs the TR515 out from Extended mode When TR515 has logged out from Extended mode TR515 cannot use extended commands anymore except commands i o and s Get login status s 73H Possible error codes none Command 5 19 TR515 User s Manual Reply AMMcc MM login status 00 logged out extended mode 01 logged in extended mode cc checksum This command gets the current login status of TR515 Use this command to check if TR515 is in Extended mode or not before use other extended commands Terminal sends captured data to Host n 6EH Possible error codes none Command nNNNN ccc c E YYYY MM DD hh mm sscc Reply A NNNN record number in Hex form ccc c ID code E event 0 OUT 1 IN YYYY year MM month DD date hh hour mm minute ss second cc checksum This command is used to send the currently captured record to Host The returned record number is supplied in Hex format The TR515 also stores this captured record into its database memory Host should acknowledge that the captured record has received successfully by command a 61H or requires TR515 to send the captured record again by command r 72H when data receiving failure Returned data string contains the record number ID code
7. be available it doesn t matter which one you use just make sure that you are using both wires of the same wire pair To connect the TR515 to the twisted pair bus cut the RS232 cable supplied with each TR515 and locate 2 wires inside Orange and Green Attach each wire to one of the wires on the twisted pair bus Mind the polarity Orange and Green wires cannot be switched It is recommended that you keep the length of each bus stem i e the cable that is used to attach a certain TR515 to the bus as short as possible ideally under 10 cm see the drawing below lt 10cm CON485 485 Green 6 4 485 485 Blue 3 Blue One side of the bus must be attached to the CON485 Orange connects to pin 3 Green connects to pin 4 Another side of the twisted pair bus must be properly terminated This is especially important for long buses Standard termination resistor value is 120 Ohm Note It is not always necessary to have the termination resistor It really depends on the actual wiring and connection circumstances Before testing the network make sure that all Terminals and the CON485 are powered and that the CON485 s baudrate selector is in the 19200 position selector must be set prior to powering the CON485 up TR515RX s interface connector pin assignment can be found in Appendix B TR515 User s Manual 2 Ethernet Interface Versions The TR515EX is designed to attach directly to the RJ45 10B
8. bell control There are two bell modes are set by group 1 register 84H Everyday mode and Week mode Everyday mode has only one table setting for everyday use Up to 32 different ring times can be specified in the table which the bell will be activated Each bell table entry consists of two fields time field string format set through these 32 group 1 registers and a corresponding enable disable field set through group 1 registers 22H 41H 26 TR515 User s Manual Bell table Everyday mode enable disable group 1 registers 22H 41H Set Possible error codes 04 07 Command CRR SS Reply A Get Possible error codes 04 07 Command BRR Reply ASScc RR register number group 1 in the Hex form 22H 41H SS state 00 disabled 01 enabled cc checksum The TR515 features a relay that can be used for external bell control In Everyday mode only one bell table can be set for everyday use Up to 32 different bell times can be specified for which the bell will be activated Each bell table entry consists of 2 fields time field string format set through group 1 registers 02H 21H and a corresponding enable disable field set through these group 1 registers Example programming a bell table entry for 12 00 00 First set the desired time select a time register that you haven t used yet i e 05H Set the time using the following command C05 1200 Next enable this time throu
9. e with codes outside of 20H 7FH range then these characters are substituted for _ If ID code length is outside of valid margins then entire ID code is substituted for the following code 0000000000 ten 0 characters e Date If the date is invalid i e December 324 then default date 1999 01 01 is used e Time If the time is invalid i e 24 00 00 then default time is used e Event if Event code exceeds 1 then this field is substituted for 0 Note for J IS II code the valid length of ID code is 1 lt margin lt 69 for Trackl code the valid length of ID code is 1 lt margin lt 76 for Track2 code the valid length of ID code is l lt 17 TR515 User s Manual margin lt 37 Initialize the database E 45H Possible error codes none Command E Reply A Executing this command initializes the database This command can be used to delete all database data and restore the database functionality in case of database malfunction E command doesn t really delete the data itself just some internal database housekeeping is initialized The data can still be partially recovered using an M command Prepare for database recovery M 4DH Possible error codes none Command M Reply A This command alters the database in such a way that it appears to be 100 full The M command therefore can be used for data recovery purposes Fo
10. ee 0o o Checking existing firmware FMM check To check if the currently downloaded application firmware is valid e Switch the TR515 off e Press and hold both IN and OUT buttons then switch the TR515 back on while keeping both buttons pressed The unit will generate a long beep and display FLCH FLASH check pag os D a IDA e Memory checkup takes about 5 seconds to complete OUT LED is on while check is in progress Upon test completion the TR515 will either display DONE in case the FLASH memory contains a valid program or Err4 if internal program code is invalid 38 TR515 User s Manual 6 Test mode The TR515 provides a hardware Test mode that can be initiated by issuing a Z command see Section 3 Warning Hardware test destroys the database contents not just deletes it logically so the data cannot be recovered even using the M command The test mode also sets a so called Reset flag the TR515 will be completely reinitialized on the next power up after the test Once initiated the Test mode cannot be exited other than by switching the TR515 off The Test mode is comprised of two phases Phase 1 performs automated SRAM RTC real time clock and FLASH memory tests Phase 2 consists of manual button and reader tests Phase 1 begins immediately upon entering the Test mode The LED displays TEST at this time Le CL bm i BG A number of errors can occur during this portion of the test All er
11. errors tha may result from each command execution c Hex Description cs Errors c c IR 4 6 7 D 44H Select designated terminal Notel jl 49H Setnew machine number Y 59H Getmachine number 5 53H Setdate time T 54H Getdate time V 56H Get firmware version R 52H Initialize the terminal C 43H Setgroup 1 registers see group 1 table B 42H Getgroup 1 registers see group 1 table N 4EH Getnumber of records G 47H Getspecified record t 4 E 45H Initialize the database M 4DH Prepare for database recovery P 50H Setgroup 2 registers see group 2 table Q 51H Getgroup 2 registers see group 2 table Ji 4A Set group 3 registers see group 3 table K 4B Get group 3 registers see group 3 table zZ 5AH Perform self test Note 2 Note 1 D command never returns error message even if the data supplied in the command packet is incorrect Invalid command packet makes it impossible to determine which terminal is being addressed and therefore which one should reply with an error code TR515 User s Manual Note 2 Self testtakes place on the next power up not immediately The TR515 have 3 group registers Group 1 is for accessing registers for LED mode bell duration 32 entries of bell table times fiel
12. selection table Up to 32 different scheduled times can be specified for which the event selection will be activated Each event table entry consists of 2 fields time field string format set through group 1 registers 44H 63H and a corresponding event selection IN OUT field when you set value not 00 or 01 this entry will be disabled set through these group 1 registers Bell table mode group 1 register 84H Set Possible error codes 04 07 Command C84 MM Reply A Get Possible error codes 04 07 Command B84 Reply AMMcc RR register number group 1 in the Hex form 84H MM bell table mode 00 everyday mode 01 Olweek mode cc checksum 29 TR515 User s Manual This group 1 register is used to set the bell table mode TR515 have two bell table modes Everyday mode and Week mode Everyday mode has only one bell table which have 32 different bell times can be specified for everyday to activate the bell Week mode have 7 tables express from Sunday to Saturday each table have 32 different bell times and can be specified for the day of week to activate the bell Daylight saving time group 1 registers 85H 86H Set Possible error codes 04 07 Command CRR MMDD Reply A Get Possible error codes 04 07 Command BRR Reply AMMDDcc RR register number group 1 in Hex form 85H 86H MM month DD date cc checksum The TR515 provides Daylight Saving Time func
13. the format of the D command issued by the Host which can only be in the Machine Number field no particular terminal can be sure that it is being addressed Therefore no terminal on the network assumes responsibility for sending a reply Command failed situation can only arise because of incorrect machine number setting value in the TR515 memory In this case the terminal will be unable to compare its internal machine number with the one supplied in the D command Hence the Terminal will not be able to make sure that itis being addressed Since 00 is a universal machine number it works with any terminal Use it only when you have a single terminal connected to the host Universal machine number also comes handy during initial terminal setup to assign a unique machine number to the terminal prior to placing it on a multi terminal network The terminal replies with its actual machine number even if you address it using 00 The only exception is when the terminal is unable to retrieve its own machine number due to some internal malfunction Reply will contain 00 instead of an actual machine number in this case Set new machine number 49H 11 TR515 User s Manual Possible error codes 04 07 Command INN Reply A NN machine number in Hex form 00H FFH 00 should never be used on a multi terminal network because this is a universal number see D command description for details This command is use
14. version Although version string can be any ASCII string the following format is adopted VXXX CC a C where VX XX is a version number i e V1 81 and cc c is a comment string Comment string is separated from the version number by a single space character Version number will never have any spaces in it Initialize the terminal R 52H Possible error codes none Command Reply A This command is used to initialize the TR515 Initialization takes place on the next power up not immediately Upon initialization all setting values are restored to their factory defaults TR515 s internal date and time are also checked and if contained garbage initialized to 1999 01 01 and 00 00 00 respectively The database data is not erased this must be done using the E command Note When first time turn power up for TR515 after received R command it will take 25 seconds to restore all factory defaults in the meanwhile LED will display INIT please wait for this initialization procedure to complete 13 TR515 User s Manual m l Set group 1 registers C 43H Possible error codes 04 07 Command CRR reg_data Reply A RR register number group 1 in Hex form 00H FFH reg_data the data for the register to be set This command is used to set one of the TR515 group 1 registers Registers are actually functioning parameters Settings Complete d
15. 515 s machine number For multi terminal RS485 communications you must make sure that all Terminals on the network have unique machines numbers Machine number is a network address that uniquely identifies the Terminal on the network Having two different Terminals on the network set up to the same machine number will result in the inability to communicate with both Terminals Machine number can be in the 0 to 255 range 00 F F Hex 0 is a universal machine number any Terminal responds to it regardless of this Terminal s actual machine number setting Machine number of 0 can be used for RS232 communications you only have a single Terminal in this case so you can address it with the universal number For multi terminal RS485 communications you ll need to assign a unique and non zero machine number to each Terminal on the network Assigning machine numbers The TR515 offers a fast and convenient way of assigning machine numbers in the range from 0 to 10 To assign a new machine number Power the Terminal down unplug the power cord Press and hold the OUT button Power the Terminal up while continuing to hold down the OUT button After 2 3 seconds the Terminal will beep and display its current machine number for example mu Luc While still keeping the OUT button pressed push the IN button several times if necessary to change the machine number to the desired value When the desired machine number is displayed release t
16. H 1FH Bell table of Sunday time field 32 registers 20H 3FH Bell table of Monday time field 32 registers 40H 5FH Bell table of Tuesday time field 32 registers 60H 7FH Bell table of Wednesday time field 32 registers 24 TR515 User s Manual 80H 9FH Belltable of Thursday time field 32 registers AQH BFH Bell table of Friday time field 32 registers COH DFH Belltable of Saturday time field 32 registers Table below lists all available group 3 registers 00H 1FH Bell table of Sunday enable disable field 32 registers 20H 3FH Bell table of Monday enable disable field 32 registers 40H 5FH Bell table of Tuesday enable disable field 32 registers 60H 7FH Bell table of Wednesday enable disable field 32 registers 80H 9FH Bell table of Thursday enable disable field 32 registers AOH BFH Bell table of Friday enable disable field 32 registers COH DFH Bell table of Saturday enable disable field 32 registers LED display mode group 1 register 00H Set Possible error codes 04 07 Command C00 MM Reply A Get Possible error codes 04 07 Command B00 Reply AMMcc MM display mode 00 wal This group 1 register is use as a wall mount and as a desk mount operation 01 desktop operation cc checksum d to set th
17. OH BFH program for Friday table and group 2 registers COH DFH program for Saturday table Each table has 32 bell table entries each bell table entry consists of 2 fields time field string type set through these group 2 registers 00H DFH and a corresponding enable disable field set through group 3 registers 00H DFH Bell table Week mode enable disable group 3 registers 00H DFH 34 TR515 User s Manual Set Possible error codes 04 07 Command JRRSS Reply A Get Possible error codes 04 07 Command KRR Reply ASScc RR register number group 3 in the Hex form QOH DFH SS state 00 disabled 01 enabled cc checksum The TR515 features a relay that can be used for external bell control Up to 7x32 different bell times can be specified for one week to activate the bell These 7x32 bell times are programmed into 7 tables from Sunday to Saturday group 3 registers OOH IFH program for Sunday table group 3 registers 20H 3FH program for Monday table group 3 registers 40H 5FH program for Tuesday table group 3 registers 60H 7FH program for Wednesday table group 3 registers 80H 9FH program for Thursday table group 3 registers AOH BFH program for Friday table group 3 registers COH DFH program for Saturday table Each table has 32 bell table entries each bell table entry consists of 2 fields time field string type set through group 2 registers O0H DFH and a corresponding enab
18. Settings Group 1 registers can be written to using the C command and read from using the B command Group 2 registers can be written to using the P command and read from using the Q command Group 3 registers can be written to using the command and read from using the K command see Section 3 for details Table below lists all available group 1 registers 00H LED display mode 0 wall mount 1 desktop 01H Bell duration in seconds OOH F FH 02H 21H Bell table times total of 32 registers 22H 41H Bell table enable disable total of 32 registers 42H Event selection mode free IN or OUT IN only OUT only or scheduled 43H Relay function 0 for Alarm 1 for Door unlock 44H 63H Event table times total of 32 registers 64H 83H Event table event selection IN 1 OUT 0 84H Bell table mode Everyday or Week Everyday 0 Week 1 85H 86H Daylight Saving Time start time end time 87H Enable or Disable Daylight Saving Time function 88H Door unlock duration in seconds 00H FFH 89H Prefix to match 0 16 characters 8AH From character extract from a character position in the ID code this setting is from 1 to 37 8BH Number of characters extract a portion of code from ID card this setting is from 1 to 37 8CH Allow or disallow record duplication 1 allow 0 disallow Table below lists all available group 2 registers 00
19. T in the meanwhile A number of errors may occur during the download Errors are displayed in the ER Rx format where x is the error number for example Lr rE In addition the TR515 generates a beep pattern comprised of a long beep followed by one or several short beeps The number of beeps corresponds to the error number All possible download related error codes are listed in the table below Errl Communications error invalid data received from the PC The most probable cause of this error is incorrect communications parameters you ve set in the HyperTerminal Err2 The download file is too big exceeds 64K All TR515 firmware files must be exactly 64K in size Make sure you are trying to downloading a correct one Err3 FLASH memory failure This normally indicates a serious internal malfunction The LED display is turned off after displaying the message for some time 37 TR515 User s Manual Finally there is a timeout error that occurs when you start the download but PC doesn t send any data or the TR515 cannot receive the data sent by the PC This happens when you either set communications parameters of the HyperTerminal incorrectly or if you switch the TR515 on with the IN button pressed before starting the XMODEM on the PC side it should always be the other way around start XMODEM first then switch the TR515 on The timeout error is indicated by a long beep and four dashes displayed by the LED
20. TR515 Time Recorder V1 5 1 amp PROMAG Attention Firmware Management mode FMM func The TR515 has two different modes of operation Normal mode provides regular device ionality Firmware Management mode FMM is provided for internal firmware checkup and upgrades see Section 5 The Normal mode is entered by powering the TR515 up while not pressing the IN button Switching the TR515 on while holding the IN button or both IN and OUT buttons down forces the unit into the FMM The FMM mode of operation cannot be exited other than by switching the TR515 off and back on again Attention Firmware Management mode FMM Eonlenbaan a 1 Installing BETRS Deus nenne 1 ZIUSINGTHE TRS Deere 7 3 COMMUNICATIONS PFOTOCO une 8 OOO ISEETS ans oariacten aaa 24 5 Firmware Management mode 36 O Test MOG Gs ea onii aniani ann 39 Appendix A Possible Errors neeeeeennenennne 41 Appendix B Interface connector pin assignment 41 Appendix C Caples sao corres cat amantte hae Pan 42 Appendix D Specifications eine 44 Appendix E Ordering Information een 44 AppendisE amp Installalona an a 46 TR515 User s Manual 1 Installing the TR515 OUT button amp LED IN button amp LED N is oat f DC Jack Comm Status Bell Control Magnetic barcode Comm Port head on this side Wall mount and desktop operation The TR515 can be used either as a wall mount default see Fi
21. alue for this Setting is 37 Allow disallow record duplication group 1 register 8CH Set Possible error codes 04 07 Command C8C MM Reply A Get Possible error codes 04 07 33 TR515 User s Manual Command B8C Reply AMMcc MM allow disallow record duplication 00 disallow 01 allow cc checksum This group 1 register is used to set allow or disallow record duplication When set in disallow mode TR510 will check if ID code and IN OUT selection is same as previous record in one minute if same the warning message is indicated by a long beep and DUPL displayed by du PL Bell table Week mode times group 2 registers 00H DFH Set Possible error codes 04 07 Command PRR hhmm Reply A Get Possible error codes 04 07 Command QRR Reply Ahhmmcc RR register number group 2 in Hex form 00 DFH hh hour mm minutes cc checksum The TR515 features a relay that can be used for external bell control Up to 7x32 different bell times can be specified for one week to activate the bell These 7x32 bell times are programmed into 7 tables from Sunday to Saturday group 2 registers OOH IFH program for Sunday table group 2 registers 20H 3FH program for Monday table group 2 registers 40H 5FH program for Tuesday table group 2 registers 60H 7FH program for Wednesday table group 2 registers 80H 9FH program for Thursday table group 2 registers A
22. aseT Ethernet connector Standard magnetic circuitry YCL part 20F001N has been included onboard to provide a glueless interface to the Ethernet network Most Ethernet installations require cables of substantial and variable length so you will probably need to make your own cables For testing purposes PROMAG supplies two kinds of Ethernet cables device to hub WAS 1499 for connections through a standard Ethernet hub and device to device WAS 1498 for connections without a hub i e directly from one Ethernet device to another gee Ve Fer WAS 1499 HUB TR515 to HUB TR515 to PC Summary of Status LED signals In the Serial Programming mode Green and Red LEDs are blinking Green Red Green TR515 User s Manual Red Led Green Led 10BaseT Port BELL CONNECTOR TR515 CONNECTOR AND STATUS TR515EX s interface connector pin assignment can be found in Appendix B 3 Wireless Interface Versions The TR515WX designed to operate in the 433MHz ISM Industrial Scientific and Medical frequency band It features Frequency Shift Keying FSK modulation and demodulation capability You must purchase a Master station RDL401A to connect with PC o H Oboe RDL401A Wireless Communication TR515 User s Manual Understanding machine numbers For single terminal RS232 communications you needn t specify your TR
23. base in this situation Communications with the TR515 from the PC side is still possible however This gives you an opportunity to access the TR515 online and attempt to correct the problem TR515 User s Manual 3 Communications protocol The TR515 communications protocol is based on the GNET protocol specification Communications parameters are 19200 8 N 1 Communications between the TR515 and the PC takes place in the form of commands sent by the PC and replies from the TR515 Commands and replies are packets of data Each packet begins with an STX 02H character and ends with CR ODH character Selected commands and replies include a checksum field as an additional safety measure All characters between the STX and the CR characters must be in the 20H 7FH range The STX character of a command packet is followed by a one character command code The STX character of a reply packet is followed by a one character reply code Both command and reply packets may contain some relevant data after the command reply character STX Cmd Rpl Cl C2 CR 02H code Data if any Checksum 0DH Checksum field is notincluded into certain commands and replies All available commands are described later in this Section Of reply codes only two are possible A completed successfully and N some error was encountered Depending on the command given to the TR515 reply packets with reply code
24. ble error codes 04 07 Command B43 Reply ALLcc LL relay function 00 for Alarm 01 for Door Lock cc checksum The TR515 features a relay that can be used for external bell or door activation control And it also has corresponding duration setting for bell or door activation individually See register 01 for bell duration setting register 88H for door unlocking duration setting Event table times group 1 registers 44H 63H Set Possible error codes 04 07 Command CRR hhmm Reply A Get Possible error codes 04 07 Command BRR Reply Ahhmmcc RR register number group 1 in Hex form 44H 63H hh hour mm minutes cc checksum 28 TR515 User s Manual The TR515 features an event schedule table Up to 32 different scheduled times can be specified for which the event selection will be activated Each event table entry consists of two fields time field string format set through these 32 group 1 registers and a corresponding event selection IN OUT field set through group 1 registers 64H 83H Event table selection mode IN OUT group 1 registers 64H 83H Set Possible error codes 04 07 Command CRR SS Reply A Get Possible error codes 04 07 Command BRR Reply ASScc RR register number group 1 in the Hex form 64H 83H SS state 00 OUT 01 IN Others disable this register cc checksum The TR515 features an event
25. cast 8 Open the Application Program of TR515 Input the IP address of the on line TR515 and select Com Port as DS100V2 Then double click 000 default to complete the connection with TR515 48 TR515 User s Manual terminal E71 TR515 Tool 1 2 R9 iol x Settings Ring Table Time Scheduler Device List Device Name u R515 Firmware Version V1 6 Com Port Select psi oov2 pl192 168 100 232 Add Delete Set M SetTime Display Reset PC to TR515 using cable WAS 1498 1 Please refer to above procedure 1 7 for settings 2 Open the Application Program of TR515 Inputthe IP address of the on line TR515 and select Com Port as DS100V2 Then double click 000 default to complete the connection with TR515 terminal P S The IP address of PC and TR515E must be within one domain to ensure the Connection Hix Settings Ring Table Time Scheduler Device List cence Name Status F R515 Firmware Version V1 6 Com Port Select ost 00v2 x ip 192 168 100 232 Add Delete Set M Set Time Display Reset 49 TR515 User s Manual 2 Wireless Interface TR515 1 Open the Application Program of TR515 Select the Com Port Jof the on line TR515 Then double click 000 defaultito complete the connection with TR515 terminal P S Please make sure that the settings of RDL401A 00 are 433 92 MHz 19200 bps Pere Settings Ring Table Time Sche
26. cation does not know these cards have read into database application retrieves records but does not include these new read in records when it erases database these new read in records will be erased as well this will cause lose data Now the new auto lock function will prevent data was deleted inadvertently when application stops database retrieving TR515 will wait 3 seconds for receiving command E if E command has received TR515 erases database then unlock itself user s card can be read again or until 3 seconds Time out TR515 still has not received E command however it will unlock itself but does not erase database Returned data string contains the record number ID code of the ID card that was used to create this record event code i e which button was pressed and the date and time of record creation The TR515 verifies all database records before sending them out to the PC This is done because the FLASH memory may actually contain a garbage data There is a special M command that lets you initialize the database in such a way that it appears to be 100 full you can recover entire database memory contents then Naturally some database records may turn out to contain invalid data Database record validity is verified on a field by field basis Should the field turn out to be invalid its contents are substituted fora safe default data e _ 1D code If ID code turns out to contain illegal characters i
27. d Locking event selection IN or OUT By default the TR515 allows the User to choose the desired event IN or OUT prior to reading the ID card There is a setting provided that allows event selection to be fixed either at IN or OUT see Section 4 This arrangement may be desirable in case several TR515s are used with some machines installed at the entrance and serving for registering IN events and some machines installed at the exit and serving for OUT registration only Fixing the event prevents the User from choosing an alternative event at the moment of reading ID card There is another setting provided that allows event selection to be set either at IN or OUT depends on a pre scheduled event table The pre scheduled event table features up to 32 entries There are two fields of each pre scheduled event table entry time field and corresponding event mode IN OUT field When time reaches the scheduled time the TR515 will automatically switch event selection at IN or OUT by your setting in pre scheduled event table TR515 User s Manual 2 Using the TR515 Clocking in and out To register an event IN or OUT please push the appropriate button and has your ID card to be read For the TR515R RFID version the card is read by bringing it close to the reader lt 8 cm For the TR515M TR515B and TR515F Magnetic Visible Barcode and IR Barcode respectively the card is read by swiping it in either direction along the rea
28. d Everyday mode 32 entries of bell table enable disable field Everyday mode event lock mode Relay function event table times field 32 entries event table enable disable field 32 entries and bell table mode Everyday or Week Daylight Saving Time Enable Disable Daylight Saving Time function Door lock duration Prefix to match From Character Number of characters Group 2 is for accessing registers of 7x32 entries for bell table times field Week mode from Sunday to Saturday G roup 3 is for accessing registers of 7x32 entries of bell table enable disable field Week mode from Sunday to Saturday Extended command set for Real time access function Summarized below are all supported extended commands using in extended mode Command characters are found in the CC column all extended commands are lower case their corresponding ASCII codes in Hex CS lists commands that require the checksum in the command packet C or reply packet R Error code column lists errors that may result from each command execution Ci Hex Description cs Errors it 69H Log into Extended mode 0 6FH Log out from Extended mode s 73H Get current login status n 6EH Terminalsends captured data to Host r 72H Hostrequires Terminal to resend captured data a 61H Host acknowledges that data has rece
29. d to assign a new machine number to the terminal Machine numbers provide a way to distinguish between the terminals on a multi terminal network See D command description for more details Get machine number Y 59H Possible error codes 07 Command Y Reply ANN NN machine number in Hex form 00H FFH This command is used to retrieve the terminal s machine number Machine numbers provide a way to distinguish between the terminals on a multi terminal network See D command description for more details Set date time S 53H Possible error codes 04 07 Command SYYYYMMDDhhmmss Reply A YYYY year MM month DD date hh hour mm minutes ss seconds This command is used to set the TR515 s internal clock Date time supplied must be valid Incorrect data like 31s of February will be rejected error 04 Get date time T 54H Possible error codes 07 12 TR515 User s Manual Command T Reply AYYYYMMDDhhmmss YYYY year MM month DD date hh hour mm minutes ss seconds This command is used to getthe TR515 s current date and time Get firmware version V 56H Possible error codes none Command V Reply Aversion string Version_string length is guaranteed to not exceed 61 character all character codes are guaranteed to be in the 20H 7FH range This command can be used to verify the TR515 s internal firmware
30. der slot For the machine orientation shown on figure of page 1 magnetic barcode stripe of the ID card must face downwards Note 1 the TR515 can be programmed to fix event selection to IN or OUT only in this case event selection won t work Note 2 for automatically activation at IN or OUT event the TR515 provides a pre scheduled event table for user to arrange time and event for activation IN or OUT in a scheduled time in this mode user can directly register ID card in a scheduled event or register an event by manually push the appropriate button in this way TR515 will go back to scheduled event IN or OUT when finish the card reading If user does not has his ID card to be read after press a button TR515 will automatically go back to scheduled event after 5 seconds Time out The last four digits of the ID cards ID code are displayed on the LED when the ID card is read Err is displayed and meanwhile beeps three times in case of read error Memory full status When the database memory is full new records cannot be added Reading an ID card will produce a long beep and a FULL message cis do Do Dl D Da Error conditions The TR515 can detect and notify you of a number of different error conditions Please refer to Appendix A for complete list of all possible errors Normal operation of the TR515 is suspended upon encountering an error condition other than card read error New records cannot be added to the data
31. duler Device List m n EEE fiRS15 Firmware Version V1 6 Port Select com gt pl s2 168 100 232 Add Delete Set M Set Time Display Reset Notice for Operation A ID 000 defaultican be set to any TR515 on line However when there are multiple TR515 on line the machine ID cannot be 000 Each TR515 must have its own ID number other than 000 B Time Scheduler will not work when the machine ID is 000 It will be enabled when other ID code is selected C Use 000 default to assign the new ID After setting use the new ID to complete the connection a Click Add to increase a new IP Address PER Settings Ring Table Y Records Time Scheduler Device List Peachey FTRS10 Firmware Version V1 6 001 Machine 1 Com Port Select com z English i mo oo 0 0 Delete Set M Set Time Display Reset b Select SetM to assign the new ID 50 TR515 User s Manual Assign new ID xl Select ID address download to TR515 Ok Cancel c SetiD as 001 The correspondent name can be modified at Device Name E71 TR515 Tool 1 2R9 001 Machine 1 3 lElx Settings ji Ring Table Y Records if Time Scheduler Device List 000 Default pooR E Success Com Port Select Ds100v2 r Ho 0 0 0 Add Delete Set M SetTime Display Reset d Toaddanew ID pls follow the installation procedure
32. e LED display mode Because TR515 can be used both op device the LED data must be displayed in either orientation Setting register to 00 default adjusts LED picture for wall mount operation Setting the register to 01 rotates the image so that it appears correctly when operating as a desktop device Note the mode parameter must be supp will generate error 04 ied as a 2 digit number i e 00 or 01 Supplying just one digit 25 TR515 User s Manual Bell duration group 1 register 01H Set Possible error codes 04 07 Command C01 DD Reply A Get Possible error codes 04 07 Command B01 Reply ADDcc DD Bell duration in seconds in Hex format 00H FFH cc checksum The TR515 features a relay that can be used for external bell control Bell schedule can be programmed using bell table group 1 registers 02H 21H 22H 41H This register specifies the number of seconds the bell will be activated for each time itis enabled Note the DD parameter must always be a 2 digit number i e 3A Supplying just one digit will generate error 04 Bell table Everyday mode times group 1 registers 02H 21H Set Possible error codes 04 07 Command CRR hhmm Reply A Get Possible error codes 04 07 Command BRR Reply Ahhmmcc RR register number group 1 in Hex form 02 21H hh hour mm minutes cc checksum The TR515 features a relay that can be used for external
33. elect an appropriate COM port from the Connect Using drop down box for example Direct to COM1 o When COMx Properties dialog appears set communications parameters as follows Bits per second 19200 Data bits 8 Parity None Stop bits 1 Flow control None o The HyperTerminal s main window will appear e Choose Transfer gt Send file from the Main menu the Send file dialog will appear e Inthe Send file dialog select the file you want to download and choose Xmodem protocol from the Protocol drop down box e The Xmodem file send for dialog will be displayed e Press and hold the IN button then power up the TR515 while still keeping the IN 36 TR515 User s Manual button pressed The unit will generate a long beep and display FLLD FLASH Load _ ILLL e When receiving the file the TR515 will blink its IN LED the LED is on while the TR515 is receiving or expecting to receive a block of data from the PC the LED is off while the TR515 is programming the data received into its internal FLASH memory e Once the downloading is finished the TR515 will execute one long beep and display DONE i 5 Li S e You may start using the newly downloaded firmware after switching the unit off and m back on again Note TR515 will set default value for all internal registers when turn power up TR515 at first time after downloaded firmware This initialization procedure will take 25 seconds and LED will display INI
34. escription of all available registers can be found in Section 4 Get group 1 registers B 42H Possible error codes 04 07 Command BRR Reply Areg_datacc RR register number group 1 in Hex form 00H FFH reg_data is the data stored in the register cc checksum This command is used to retrieve the data contained in the designated group 1 registers Registers are actually functioning parameters settings Complete description of all available registers can be found in Section 4 Set group 2 registers P 50H Possible error codes 04 07 Command PRR reg_data Reply A RR register number group 2 in Hex form 00 FFH reg_data is the data for the register to be set 14 TR515 User s Manual This command is used to set one of the TR515 group 2 registers Registers are actually functioning parameters Settings with respect to access bell table s time field 7x32 entries from Sunday to Saturday Complete description of all available registers can be found in Section 4 Get group 2 registers Q 51H Possible error codes 04 07 Command QRR Reply Areg_datacc RR register number group 2 in Hex form 00H FFH reg_data is the data stored in the register cc checksum This command is used to retrieve the data contained in the designated group 2 registers Registers are actually functioning parameters settings with res
35. gh a corresponding enable disable register The corresponding enable disable register for time register 05H is 25H time registers start from 02H enable disable registers start from 22H we use the 4 register of each group Enable command looks like this 25 01 Event selection mode group 1 register 42H Set Possible error codes 04 07 Command C42 EE Reply A Get Possible error codes 04 07 Command B42 Reply AEEcc EE event selection mode 00 free selection by the User 01 fix to OUT 02 fix to IN 03 27 TR515 User s Manual scheduled selection cc checksum This setting allow User to set the TR515 at one of 3 event selection modes se free mode IN or OUT by user selection set event selection mode at fix to IN only or the event at OUT only or set at scheduled selection mode Fixing event may be desirable in case several TR515s are used with some machines installed at the entrance and serving for registering IN even ts and some machines installed at the exit and serving for OUT registration only TR515 features scheduled selection mode which allow user to arrange event activation in a scheduled time event schedule table s time field set by group 1 registers 44H 63H event schedule table s IN OUT field set by group 1 registers 64H 83H Relay function group 1 register 43H Set Possible error codes 04 07 Command C43 LL Reply A Get Possi
36. gure above or desktop device Machine needs to be rotated 180 degrees when used on a desk For this reason the TR515 comes with two different LED plates with their artworks rotated 180 degrees with respect to each other Machine s LED can also display time and other data in a normal wall mount or desktop fashion There is an orientation setting provided that allows you to select display mode see Section 4 1 RS 232 485 Interface Versions The TR515 supports two different interfaces RS232 for single terminal communications and RS 485 for multi terminal communications Only one TR515 can be attached to the PC s serial port using the RS232 interface Up to 32 units can be interconnected using the multi terminal RS485 communications RS232 arrangement is simple just plug the RS232 cable supplied into the TR515 and connect the other side to the PC s serial port Using RS485 requires a special adaptor CON485 must be purchased separately CON485 is a smart RS232 gt RS485 converter that allows for higher data transfer rates between the PC and TR515s The RS485 network is of bus type all TR515s are connected in parallel on a so called twisted pair bus The most suitable cable for the bus is the one normally used for Ethernet 1 TR515 User s Manual communications twisted pair Cat Ill or V You only need to use one twisted pair of wires inside the cable Note depending on the cable type up to 4 twisted pairs may
37. he OUT button the Terminal will resume normal operation This method allows you to set the numbers in the 0 10 range only which would actually cover most of the actual installation requirements If you need to set the machine number to say 25 then you will have to follow this procedure Connect the TR515 to the PC using the RS232 cable Launch the TR515 Control Center software and select the Terminal 0 i e use the universal machine number to address the Terminal Use the Set M button to set the new machine number for this Terminal Unplug the RS232 cable and put the Terminal back on the RS485 network TR515 User s Manual Note machine number is displayed briefly at the Terminal power up even if you don t push the OUT button Bell relay The TR515 features a built in bell relay The relay is capable of controlling a low power external bell There are two modes for bell schedule one is Everyday mode another is Week mode There is only one table in Everyday mode a daily bell schedule of up to 32 different bell times can be defined in Everyday mode Seven bell schedule tables can be defined from Sunday to Saturday in Week mode and each table also has up to 32 different bell times can be defined NO COM NC Relay connector is located at the metal back plate Figure above shows connector position and pin assignment Both Normally Closed N C and Normally Opened N O contacts are provide
38. hour mm minute ss second cc checksum If data receiving is failure host can require TR515 to resend currently captured record by this command And then TR515 will resend the currently captured record by n 6EH command again see n 6EH command description for details Host acknowledges data received successfully a 61H Possible error codes 09 Command a Reply However host must send this command to TR515 to acknowledge the data has received successfully After send captured data to host TR515 will wait host to send this command for 5 seconds during this 5 seconds TR515 will reject any card reading Therefore host shall acknowledge this command as soon as possible Hostsends 4 digits message to display d 64H Possible error codes 04 09 Command dNNNNss Reply A NNNN 4 digits message 0000 9999 in string type ss message display duration in seconds 01 99 also string type 21 TR515 User s Manual This command is used to display 4 digits message on TR515 s LED display for a duration time The message code and its meaning is defined by user only numeric can be defined do not define alphabet The code range is from 0000 to 9999 in string type Host sends relay activation duration 6CH Possible error codes 04 07 09 Command INN Reply A NN relay activation duration in 01 99 string type seconds 00 should ne
39. ived successfully d 64H Hostsends 4 digits message to display ul 6CH Host sends the Relay activation duration The command l is lower case of L p 70H Setpunch times u 75H Getpunch times 10 TR515 User s Manual Follows is the detailed command description Command and reply packets are shown without STX Checksum and CR characters Select designated terminal D 44H Possible error codes none Command DNN Reply ANN TR51x NN is a machine terminal number in Hex form 00H FFH QOH is a universal number see below for details D is a special command It is used to select a particular TR515 terminal All terminals power up in a deselected state Each terminal ignores all incoming commands until it receives the D command whose machine number is either equal to the machine number of this terminal or 00 After that the terminal switches into selected state and responds to all subsequent commands until new D command with a different machine number is issued Thus the D command should always be used to initiate communications between the host and the designated TR515 Note the TR515 never returns any error codes in reply to this command This holds true for both illegal command error and Command failed error The former is not responded to because when there is some discrepancy in
40. le disable field set through these group 3 registers 0OH DF H 35 TR515 User s Manual 5 Firmware Management mode The TR515 also features new Firmware Management mode FMM FMM allows you to quickly upgrade your TR515 s internal firmware and also check validity of the currently loaded firmware Contact your dealer for the most recent firmware upgrade files FMM itself has two sub modes of operation FMM download mode and FMM check mode FMM download is entered by keeping the IN button pressed while the TR515 is powering up FMM check mode is entered by holding both IN and OUT buttons pressed while the TR515 is powering up Downloading new firmware FMM download To upgrade the firmware you will need a new firmware file and a terminal software for PC capable of transferring files using Xmodem protocol Checksum version All TR515 firmware files have a fixed size of exactly 64K 65536 bytes The list of popular and widely available terminal programs includes HyperTerminal for Windows QModem and Term95 Procedure below assumes the use of HyperTerminal which is a part of a standard Windows 95 98 distribution To upgrade the TR515 s internal firmware e Switch the TR515 off e Make sure that the TR515 and the PC are interconnected with a serial cable e Launch HyperTerminal and configure it as follows o When Connection Description dialog opens type any string 1 character minimum and press OK o When Connect to dialog opens s
41. lock duration group 1 register 88H Set Possible error codes 04 07 Command C88 DD Reply A Get Possible error codes 04 07 Command B88 Reply ADDcc DD Door unlock duration in seconds in Hex format 00H F FH cc checksum The TR515 features a relay that can be used for external bell or door lock activation control This register specifies the number of seconds for the Door lock relay activation duration Please see register 01 for the Bell relay activation duration Prefix to match group 1 register 89H Set Possible error codes 04 07 Command C89 prefix_string Reply A Get Possible error codes 04 07 Command B89 Reply Aprefix_stringcc 31 TR515 User s Manual prefix_string is the string of prefix to be set 0 16 digits long cc checksum Prefix to match allows you to restrict the User ID cards accepted by the TR515 to cards whose leading ID code characters match those of the prefix string This way you can setup the system to accept only certain ID Cards You can even implement a simple access control function using the TR515 as an Control Terminal The prefix can be from 0 to 16 digits long Entering a string with O none character disables prefix checking any readable User Card will be accepted If the Prefix String is set the TR515 will compare each User Card with this String and reject the Cards that do not match for example If Prefix to ma
42. me Recorder with RFID Card Reader TR515SB Time Recorder with Barcode Card Reader visible TR515SF Time Recorder with Barcode Card Reader infrared TR515SH Time Recorder with HID Card Reader TR515SMF Time Recorder with Mifare Card Reader 45 TR515 User s Manual Appendix F Installation Please install DISK5151 Software before using TR515 series DISK5151 includes DS Manager and TR515 Application Program Setting procedure is as follows 1 Ethernet Interface TR515 Hub to TR515E using cable WAS 1499 1 Open the program DS Manager It will automatically detect the IP Address of the TR515 on line The default IP address is 127 0 0 1 For DS Manager cannot detect the IP address in use currently on the LAN please make sure the IP address you set is not in use to avoid duplication Device Servers Local Device Servers auto discovery by broadcast 127 0 0 1 0 3 192 168 100 166 0 2 3 4 17 69 P 192 168 100 167 0 2 3 4 40 113 9 192 163 100 90 0 2 3 4 5 101 Device Servers DS gt found on your local network segment auto discovered by broadcast 2 Click Change IP to change the IP address to be used by TR515 and then click OK P S The IP address must not be the existing one TR515 User s Manual 3 Skip it by clicking OK Please enter the password for this Device Server Password I Remember password Cm 4 SelectIP Address and Click DS Settings button Pro
43. of the ID card that was used to create this record event code i e which button was pressed and the date and time of record creation The TR515 verifies the currently captured record before sending it out to the Host Captured record validity is verified on a field by field basis Should the field turn out to be invalid its contents are substituted for a safe default data e _ 1D code If ID code turns out to contain illegal characters i e with codes outside of 20H 7FH range then these characters are substituted for _ If ID code length is outside of valid margins then entire ID code is substituted for the following code 0000000000 ten 0 characters e Date If the date is invalid i e December 324 then default date 1999 01 01 is used e Time If the time is invalid i e 24 00 00 then default time is used e Event If Event code exceeds 1 then this field is substituted for 0 Note for J IS II code the valid length of ID code is 1 lt margin lt 69 for Trackl code the 20 TR515 User s Manual valid length of ID code is 1 lt margin lt 76 for Track2 code the valid length of ID code is l lt margin lt 37 Host require sending captured data again r 72H Possible error codes 07 09 Command r Reply nNNNN ccc c E YYYY MM DD hh mm sscc NNNN record number in Hex form ccc c ID code E event 0 OUT 1 IN YYYY year MM month DD date hh
44. pect to access bell table s time field 7x32 entries from Sunday to Saturday Complete description of all available registers can be found in Section 4 Set group 3 registers J 4AH Possible error codes 04 07 Command JRR reg_data Reply A RR register number group 3 in Hex form 00 FFH reg_data is the data for the register to be set This command is used to set one of the TR515 group 3 registers Registers are actually functioning parameters Settings with respect to access bell enable disable field 7x32 entries from Sunday to Saturday Complete description of all available registers can be found in Section 4 Get group 3 registers K 4BH Possible error codes 04 07 Command KRR 15 TR515 User s Manual Reply Areg_datacc RR register number group 3 in Hex form 00H FFH reg_data is the data stored in the register cc checksum This command is used to retrieve the data contained in the designated group 3 registers Registers are actually functioning parameters settings with respect to access bell enable disable field 7x32 entries from Sunday to Saturday Complete description of all available registers can be found in Section 4 Get number of records N 4EH Possible error codes 07 Command N Reply ANNNNcc NNNN number of records in Hex form cc checksum This command can be used to ret
45. perties DS a Y2 02L gt 1A Network Properties Outbound packets Serial Properties r Network settings Routng mode Device server IP Subnet Mask Router IP Destination IP Transport protocol TCP connection timeout Gn minutes Password Initialize A Select Routing mode Slave B Set IP Address When using multiple TR515E or machines it is recommended to label the IP address on each TR515E or machines C Select Transport Protocol TCP D Setting the Period of TCP Connection Timeout of TR515E 0 255 minutes Remark lf users do not have any communication with TR515E during the period of TCP connection timeout TR515 will be disconnected to TCP automatically 5 Enable Allow on the fly serial port parameter changes This helps TR515E to remote control 47 TR515 User s Manual the serial parameters 6 Click OK to finish TCP IP configuration Network Properties Outbound packets Serial Properties Serial settings Serial interface Auto Baud rate 19200 bps Parity Flow control Data bits I Enable Soft Entry Device Servers Local Device Servers auto discovery by broadcast 192 168 100 168 0 2 3 4 23 119 DS Settings 192 168 100 239 0 2 3 4 53 158 REA 192 168 100 166 0 2 3 4 17 69 Pe 9 Change IP 192 168 100 167 0 2 3 4 40 113 Address Book Add Device Servers DS ay found on your local network segment auto discovered by broad
46. r example if E command is executed accidentally while TR515 had some useful data inside then M command can be used to download entire database memory contents Naturally this recovered data may not be consistent Some records may contain garbage data more on this in G command description newer records may overlap older ones etc Perform self test Z 5AH Possible error codes none Command Z Reply This command is never replied to This command is used to force the TR515 into a special Test mode Self test takes place on the next power up not immediately Details of TR515 s operation in the Test mode are provided in Section 6 Note that Test mode destroys database memory contents in such a way that the data 18 TR515 User s Manual cannot be recovered even with the M command Note When turn power up at first time for TR515 after self test it will take 25 seconds to restore all factory defaults please wait for this initialization procedure the LED will display INIT while initialization is in progress Extended command set description Log into Extended mode i 69H Possible error codes none Command Reply A This command logs the TR515 into Extended mode whatever TR515 is currently in Extended mode or not If you want to use other extended commands TR515 should be logged into Extended mode first In Extended mode TR515 can send the captured data to Host in
47. rated during the TR515 s normal operation The table below does not apply to the Test and FMM modes of the TR515 see Sections 5 and 6 respectively for complete details on errors generated in these modes Error Description Remedy Read error ID card read error Read the card again Database The database is full and new record cannot be full added Error 4 Incorrect setting value Reinitialize the TR515 by issuing the R command Error5 The database is corrupted First try to power the Cc TR515 off and back on again If this doesn t help I Dl initialize the database using the E command or recover the database using the M command Error6 Time date is not set Use the S command to gt Pa 7 Fa correct the problem or reinitialize the TR515 using the R command Appendix B Interface connector pin assignment Ethemet Wireless RS 232 RS 485 1 TX i r 2 TX RS232 TX PC output 3 RX 4 RS232 RX PC input 6 RS 485 6 RX Ground 7 RS485 8 41 TR515 User s Manual Appendix C Cable 1 WAS 1436 For TR515WX TR515SX RS 232 I WAS 1436 LENGH 2000 mm WIRE 8P8C AWG 28 DB 9P FEMALE PIN COLOR RJ 11 8P8C PIN 7 GRAY 1 2 ORANGE 2 8 BLACK 3 3 RED 4 NC GREEN 5 5 YELLOW 6 NC BLUE 7 NC BROWN 8 NC No Connect PINL PINS 2 WAS 1467 For TR515SX RS 485
48. rieve the number of records currently found in the database Leading zeroes are not omitted so reply string length is always the same Get specified record G 47H Possible error codes 04 06 07 Command GNNNN Reply ANNNN ccc c E YYYY MM DD hh mm sscc NNNN record number starting from 0000 in Hex form ccc c ID code E event 0 OUT 1 IN YYYY year MM month DD date hh hour mm minute ss second cc checksum This command is used to retrieve the database record with a specified number Record number must be supplied in Hex format leading zeroes must be preserved or error 04 will be returned Record numbers start from 0000 Specifying record number beyond N 1 where N is the number of records in the database returned by the N command will cause error 06 When use this command to retrieve database TR515 will automatically lock itself this means it will reject card reading until database stop retrieving then user s card can be read again in the meantime LED will display busy as following 16 TR515 User s Manual bu SY This auto lock function prevent data is deleted inadvertently for some application Some application Polling database use command N to get number of records then use command G to retrieve the records at last use command E to erase database But during retrieve the records some user card s may be read into database again think of this user s appli
49. rors are displayed in the ERR x format where x is the error number for example Er rc All possible errors are listed in the table below Errl SRAM test failure Err2 RTC test failure Err3 FLASH test failure Upon successful completion of the automated tests the TR515 will beep and display b1 5 OUT LED will be switched on Et co mi This means that the manual test phase has commenced This phase consists of three steps OUT button test IN button test and reader test Each step must be repeated five times Press the OUT button and notice that b1 5 changes to b1 4 b1 3 etc When you press the OUT button for the fifth time the display will change to b2 5 and the IN LED will be switched on Press the IN button five times to finish this test step The display reads rd 5 at the beginning of the reader test Read any ID card five times to pass this portion of the test 39 TR515 User s Manual When all manual tests are finished the TR515 will generate a long beep and display PASS pa u poet ott This indicates that the test sequence has been completed successfully Y ou can still continue testing the buttons and the reader at this point The TR515 will behave as if in the Normal Mode of operation but no records will be added to the database 40 TR515 User s Manual Appendix A Possible Errors This Section lists all possible error messages that may be gene
50. tch is set to 123 then the TR515 will accept Cards such as 1234 123679 123 The terminal will reject the Cards with codes like 14377 and 12 Default value for this setting is empty string i e prefix matching is disabled From Character group 1 register 8AH Set Possible error codes 04 07 Command C8A NN Reply A Get Possible error codes 04 07 Command B8A Reply ANNcc NN a character position in the ID Code counting from 1 in Hex form range O1H 25H cc checksum From Character together with Number of characters setting allows you to extract and store into the database a portion of code from the User UD Card instead of the entire ID Card code This way you can adjust the format of the data generated by the TR515 to the requirements of some specific PC software You can also use this setting to hide a certain portion of the ID Cards code This is useful for simple access control function implementation From Character defines a character position in the ID Code counting from 1 starting from which the portion of an ID code will be extracted The valid range for this setting is from 1 to 37 The TR515 will reject any User Card with the ID code with the number of characters in it smaller than current From Character value Example Supposing that From Character 3 and Number of characters 2 Then ID code 123456 will be truncated to 34
51. tion the daylight saving start time string type is set by group 1 register 85H and the daylight saving end time string type is set by group 1 register 86H When time reaches 2 00 00 AM of the start time time will change from 2 00 00 AM to 3 00 00 AM When time reaches 2 00 00 AM of the end time time will change from 2 00 00 AM to 1 00 00 AM After finishing the start time and end time setting don t forget to enable Daylight Saving Time function by setting group 1 register 87H as 01 then the function will work immediately If set the start time same as end time the Daylight Saving Time function will be automatically disabled by TR515 itself but content of register 87H will not be changed If set the date of start time behind end time TR515 will consider the date of start time as next year date Note February 29 will be denied to set as start time or end time by TR515 Daylight Saving enable disable group 1 register 87H Set Possible error codes 04 07 Command C87 SS Reply A 30 TR515 User s Manual Get Possible error codes 04 07 Command B87 Reply ASScc SS state 00 disabled 01 enabled cc checksum The Daylight Savings Enable Disable register is use to enable or disable Daylight Saving Time function The default factory setting is 00 disabled Note when start time and end time were set as same date TR515 will automatically disable Daylight Saving Time function Door un
52. ver be used as duration This command I lower case L is used to assign relay activation duration in seconds When relay is used to control Bell send this command to TR515 will get error code command failed Set punch times p 70H Possible error codes 04 07 Command pNN Reply A NN punch times in Hex form 00H OAH 00 disable 01 0A legal value for punch times For some unknown reason device may be disconnected from network and device will lose control by Host For use device as stand alone work user can has his card to be read in several times then device will auto log out from Extended mode The p command sets punch times in range 01 to 10 01 0A in Hex format and 00 will disable this auto switching to log out mode function Get punch times u 75H Possible error codes 07 Command u Reply ANN NN punch times in Hex form 00H 0AH 22 TR515 User s Manual This command is used to retrieve the device s punch times Punch times provide a way to use device as stand alone work when device was lost control from network User has his card to be read in this defined punch times then device will be continue used in stand alone work disconnection from network 23 TR515 User s Manual 4 Registers The TR515 feature 3 groups of programmable registers Basically registers are the TR515 s functioning parameters