Home

17”LCD Drawer KVM Console with 8/16 Ports Combo

image

Contents

1. DEDEDE HODES EOS 3 2 3 OSD On Screen Display Press the NumLock on the keyboard twice or simultaneously press the Push Buttons 1 and 2 of the Port Selection Switch on the KVM panel to start the OSD Use the key Up Down and Enter keys on the keyboard to switch or directly move the mouse to the target PC and then double click the left button Additionally you also can use the numeric keys to enter the direct switch For example if you want to switch a PC to the Slave KVM port 04 under the Master KVM port 03 then you can start the OSD and then directly enter 0304 If you are using a standalone machine then just enter the first two digits More OSD related information is given in the following OSD sections Unicorn series User s Manual Start Press the NumLock twice or the Port Selection Switches 1 and 2 on the panel to enter the OSD If you have modified the Hot Key for starting the OSD and are unable to enter the OSD by pressing NumLock then you can start the OSD by using the Port Selection Switch first and then press F9 to enter into the System Setting to modify the options of the OSD Entry Hot Key If you have modified the Hot Key for starting the OSD and are unable to enter the OSD by pressing NumLock then you can start the OSD by using Port Selection Switch first and then press F9 to enter into the System Setting to modi
2. If you clear the name list under the Master screen then you will also clear the name lists under all slaves If you clear the name list under a certain slave then you only clear the name list under that particular Slave KVM F1 Smart View It switches the Smart View Setting Unicorn series User s Manual e System Setting Menu System Setting Channel Display Full Mode Channel Display Tim 5 Sec Auto Scan Time 5 Sec OSD Entry Hot Key Number Lock Hot Key Switching OFF Mouse Clicking OFF Beeper Sound ON Offline Skip Manual OSD Language English Security Level None Console Lock Time 5 Min Move Space Change Esc Exit F1 Information F4 OSD Position F8 Restore Default Setting Description Default Other Selection For Port Switching Auto Scan Channel Display and OSD Close the Monitor will Ful Number Mode show the Channel information Name and mode selection Channel Display It shows the time for displaying bann Time channel information uen Guia None 10Sec Auto Scan Time For Aulo scan it shows the 5 Sec 20Sec residing time for each port 30Sec 60Sec OSD Entry Hot Select to turn on the hot keys of Scroll Lock Key the OSD control screen Shift None Unicorn series User s Manual Turn on off the Ctrl hot keys on the keyboard for switching OFF ON computer functions Hot Key Switching T
3. commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC This device has been tested and found to comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received Including interference that may cause undesired operation CE This equipment is in compliance with the requirements of the following regulations EN 55 022 CLASS A WEEE regulation To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately Trademarks The PLANET logo is a trademark of PLANET Technology This documentation may refer to numerous hardware and software products by their tr
4. EN 61000 4 6 2007 EN 61000 4 8 1993 A1 2001 EN 61000 4 11 2004 Responsible for marking this declaration if the Manufacturer O Authorized representative established within the EU Authorized representative established within the EU if applicable Company Name Planet Technology Corp Company Address 11F No 96 Minquan Rd Xindian Dist New Taipei City 231 Taiwan Person responsible for making this declaration Name Surname Jonas Yang Position Title Product Manager Taiwan 1 Aug 2011 Place Date Legal Singnature PLANET TECHNOLOGY CORPORATION e mail sales planet com tw http www planet com tw 11F No 96 Min Chuan Road Hsin Tien Taipei Taiwan R O C Tel 886 2 2219 9518 Fax 886 2 2219 9528
5. M PLANET Networking amp Communication 17 LCD Drawer KVM 8 16 Ports Combo Free MoWmme LL wm WW p Copyright Copyright C 2011 PLANET Technology Corp All rights reserved The products and programs described in this User s Manual are licensed products of PLANET Technology This User s Manual contains proprietary information protected by copyright and this User s Manual and all accompanying hardware software and documentation are copyrighted No part of this User s Manual may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form by any means by electronic or mechanical Including photocopying recording or information storage and retrieval systems for any purpose other than the purchaser s personal use and without the prior express written permission of PLANET Technology Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a
6. OSITION OSD Adjust operation of right left on the screen H POSITION OSD OFF TIME OSD time of staying on the screen RECALL Returns all controls back to factory sorting SOURCE Analog Digital signal choice EXIT SAVE Exit OSD control Unicorn series User s Manual 3 2 KVM OSD Function 3 2 1 Manual Key It is the simplest switching method You just need to press the Port Selection Switch on the front panel of the KVM The Selection LED Red is on indicating that you are switching to the corresponding port 3 2 2 Hot Key and Mouse Clicking 1 The Port Selection Switch functions only when connected to a PC 2 If the Offline Skip of the OSD System Setting is Auto then you can not make any switch when pressing an offline Port Selection switch 3 For Auto Scan Mode none of the Port Selection Switches functions Hot key and mouse clicking are applicable for switching a small section You can select the SVS Smart View Setting from the OSD of the PC first for a quick switch of PC and use the keyboard press the Ctrl key twice or the mouse press and hold the middle button while pressing the left or right button to switch to the previous or next set of PC The mouse must have at least 3 keys As far as you select PC with Note the SVS you can use this method for the switch Poe
7. PC defined by Users If a PC connects to the Master then the number consists of the first two digits If a User has not given a name for the PC the name field will be blank Unicorn series User s Manual 2 gt This field shows the list of the Master KVM or a certain set of Slave KVM currently displayed on the OSD We recommend you to give a name to the Slave KVM or else the display after LIST will be blank 3 This field shows the list of connections to the KVM and the fields are described below PWR It shows the status of power supply and indicates a normal power supply for the equipment PC or KVM connected to the CPU port C It shows the channel number the CM 1204 will display 01 04 the CM 1208 will display 01 08 and the CM 1216 will display 01 08 09 16 Since the screen cannot display all at a time therefore you can use PgUp PgDn to switch the pages KVM It shows the KVM model If there is a number in this field it shows that a set of KVM connects to this port The number 04 indicates Port 4 and 08 indicates Port 8 and 16 indicates Port 16 and so on NAME It shows the name of the equipment and users can name the Slave KVM or PC on own There a total of 12 characters selected from the group of 7 7 O 9 __ __ P 5 i s SVS It shows the Smart View Setting use to open and to close The SVS is blank and not clicka
8. ade names In most if not all cases these designations are claimed as trademarks or registered trademarks by their respective companies Revision User s Manual for Drawer KVM Console with 8 16 Ports Combo Free Module Model DKVM 1708 1716 Rev 1 0 July 2011 Part No EM DKVM 1708 1716 v1 0 Safety Instructions 1 10 11 12 13 Please disconnect this equipment from AC outlet before cleaning Don t use liquid or sprayed detergent for cleaning Use moisture sheet or clothe for cleaning For pluggable equipment the socked outlet shall be installed near the equipment and shall be easily accessible Please keep this equipment from humidity Lay this equipment on a reliable surface when install A drop or fall could cause injury Do not leave this equipment in an environment unconditioned storage temperature above 60 OC it may damage the equipment The opening on the enclosure is for air convection hence the equipment from overheating DO NOT COVER THE OPENING Make sure the voltage of the power source connect the equipment to the power outlet Please keep the power cord such a way that people can not step on it Do not place anything over power cord The power cord must rate for the voltage and current marked on the product s electrical ratings label The voltage and current rating of the cord should be greater than the voltage and the current rating marked on the product All cautions and warning on the equipment shoul
9. ble if the KVM is connected in parallel If this option is set to open then you can make the switch by operating the Hot Key Switch or Mouse Clicking or selecting the option by Auto Scan You also can use mouse to click this field If the connected KVM is not on there will have no number in this field Please use the CapsLock to toggle the upper and lower cases Selection BAR It shows the selection bar Green you can use the 1 keys on the board to move the selection bar and the situated position indicates the selected target for giving instructions For example if the selection bar points at C 05 and you press Enter then the system will switch to that particular PC or Unicorn series User s Manual press the Space BAR to start editing the name Press F4 to enable disable the SVS option 4 Instruction Hint Field d 871 Use the 1 keys on the keyboard or the mouse to Move move the selection bar SPACE The Space on the keyboard is used to start Edit editing the name of the PC or KVM ESC Use the Esc key on the keyboard to exit the Exit current option or exit OSD F4 Use the F4 key to run Auto Scan and you can set Auto Scan the residing time channel display time and mode of the Auto Scan from System Setting F9 Use the F9 key to enter into the System Setting System Setting Menu F5 Use the F5 key to clear the values of all Name Clear Name List fields
10. d be noted If the equipment is not in use for long time disconnect the equipment from mains to avoid being damaged by transient over voltage Never pour any liquid into ventilation openings this could cause fire or electrical shock Never open the equipment For safety reason qualified service personnel should only open the equipment If one of the following situations arises get the equipment checked by service personnel a The Power Cord or plug is damaged a Liquid has penetrated into the equipment a The equipment has been exposed to moisture The equipment has not worked well or you can not get it work according to User s Manual a The equipment has dropped and damaged a the equipment has obvious signs or breakage Index of Contents Safety MSM UCHOMS te Scot I Index of Contents reip etm eee EROR HER II 1 General Informatiofi REIR ONIS QUEUE NR RM Ie RUN SIE 1 1 1 Packing M 1 L2 Product dme ONCE Td EE NU 2 2 LA Product Specification 3 iret 4 2 BeforeInstallation cioe ee s eb 4 2 2 Hardware Kits Contents 5 2 3 LCD Componenls renes EE va eL REV dE ES Ve RUE REV Y NEEE eR MR 7 2 4 Connec
11. e present computer applications a mouse has become an indispensable device The KVM fully supports various models of PS 2 mice manufactured by Logitech Microsoft and IBM as well as compatible PS 2 mice of other brands The KVM supports the PS 2 Keyboard Port of the CODE SET1 2 3 and further allows you to use the KVM for all kinds of servers PCs or their combination Unicorn series User s Manual 1 4 Product Specification Model DKVM 1708 DKVM 1716 Display Size Panel Type Resolution Capabilities Pixel Pitch Mac OS9 OSX and Sun Microsystems Multi Platform System Cables Keyboard Mouse Power Source Touch pad Connectors KB MS PS 2 amp USB signal combined Temperature Operate 5 40 Degree 41 104 Degree Storage 20 60 Degree 4 140 Degree Humidity 0 80 RH P EETEHER Heavy duty steel materials Multi Language keyboard support English Germany French Keyboard Language Italian Spanish Chinese Default English Certification CE FCC Unicorn series User s Manual 2 Installation 2 1 Before Installation 1 Please check all peripherals according the list before installation To make sure of the whole unit was not damaged and lost during shipping process If you encountered any problem please contact your dealer 2 Before installation make sure all peripherals and computer have been turned off 3 The standard brackets are for 500 800 mm distance m
12. eans front bracket to rear bracket cabinet contact your dealer if you need longer rear brackets 4 If your cabinet depth is above 800 to 1000 mm please contact your dealer for the stretch rails and replace it for your demand 5 Reliable accessories of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit 6 The KVM and console are a little bit heavy please prevent these devices from falling down during the installation That may make some people hurt and the console damage Unicorn series User s Manual 2 2 Hardware Kits Contents 1 Adjust rail with pull or push to fit your cabinet 2 Install front and rear bracket on cabinet 3 Repeat step 1 2 for the other side 4 Pull the console until rails automatically are locked When users hardly push the console and it can be unlocked by the power is over 4kg 5 Pull and turn the lock knobs left and right at the same time then users can open console to operate 6 Unicorn series User s Manual Put the KVM module into the console form the back There are two ways to install the KVM module in suitable position users can fix KVM module with the KVM accessories Both sides or the extra Rack mounted Screws Bothsides KVM accessories L amp 2 o o Extra rack mounted Screws 8 fii H hj lt 23 2 3 LCD Comp
13. el to start the Console Reconfirmed If you change the Console equipment please use this function to let KVM reconfirm the equipment at the Console end once EDID amp DDC A vast majority of computer monitors supports the Extended Display Identification Data EDID and allows data access by Display Data Channel DDC The KVM also supports these two specifications but the KVM only reads the EDID of the Monitor when the KVM is on If it is necessary to change monitors during an operation please use the Console Reconfirmed function to read the EDID again PLANET Networking amp Communication EC Declaration of Confomi For the following equipment Type of Product 17 LCD Drawer KVM Console with 8 16 Port Combo Free Module Model Number DKVM 1708 DKVM 1716 Produced by Manufacturer s Planet Technology Corp Manufacturer s Address 11F No 96 Minquan Rd Xindian Dist New Taipei City 231 Taiwan R O C is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility 2004 108 EC For the evaluation regarding the Electromagnetic Compatibility the following standards were applied EN 55022 2006 A1 2007 Class A EN 61000 3 2 2006 EN 61000 3 3 2008 EN 55024 1998 A2 2003 EN 61000 4 2 1995 A2 2001 EN 61000 4 3 2006 A 1 2008 EN 61000 4 4 2004 EN 61000 4 5 2006
14. fy the options of the OSD Entry Hot Key Operation You can operate the options by keyboard or mouse For the keyboard operation besides the common Up and Down keys there are special function keys such as Enter Space Bar Function Key F1 F4 under the OSD remark field For the mouse operation the left key refers to Enter and the right key refers to Exit For example move the mouse point to your desired PC and click the left key The selection bar will move to that position and then click the left key again for the execution 12 Unicorn series User s Manual Switch Menu Master List 1 i 03 04 Ser 4 B am LIST MASTER PWR KVM NAME SVS e 01 Admin e 02 03 04 Press Enter 3 04 e 05 Peter 06 08 Web Group O 07 16 Data Group O 08 9 tj Move Space Edit Esc Exit F1 Smart View Enter Switching 4 F4 Auto Scan F9 System Setting F5 Clear Name List Slave List 03 04 Mail Ser 4 LIST Mail Group PWR KVM NAME SVS 01 Mail Ser 1 02 Mail Ser 2 03 Mail Ser 3 04 Mail Ser 4 ty Move Space Edit Esc Exit F1 Smart View Enter Switching F4 Auto Scan F9 System Setting F5 Clear Name List 1 This field provides the information of the currently connected PC As shown in the figure above 03 refer to the Port Number of the Master 04 refer the Port Number of the Slave and Mail Ser 4 is the name of this
15. manual CD One quick installation guide Two Rack mount bracket kit a One Rack Mount Screw pack Check to make sure that the unit was not damaged in shipping If you encounter a problem contact your dealer Please read this manual thoroughly and follow the installation and operation procedures carefully to prevent any damage to the product and or any of the devices that connect to it 1 2 Product Feature Easy to install single rail design Supports high resolution up to 1280 x 1024 75Hz Support 6 keyboard languages Heavy Duty Electroplate Steel OSD function for LCD display and KVM switch Complies with EIA RS 310C 19 Rack Mount standard Supports Combo KVM module to connect servers KVM via USB amp PS 2 Connection Cascade controls 128 256 sets of PCs Fully supports Logitech Microsoft IBM PS 2 mouse trackball and compatible PS 2 mouse trackball Supports hot plug not necessary to turn off the original system regardless of a newly installed PC or KVM 1 3 Features Easy to install With the unique separate rail design One man can install the KVM console easily In case you need to maintain the console you can easily uninstall without effecting the server above or below Modular KVM switches The user can use DKVM 1708 1716 as single port console or through some simple action and few screws to be 8 16 ports KVM switch Various keyboard language support Powerful Mouse Keyboard Support In th
16. nterface connector Unicorn series User s Manual 3 OSD Operation 3 1 Panel Controls and LCD OSD Function Controls Description To access the main menu This button also acts as the Enter button Auto synchronize and scale down display to any valid factory preset timings Press to scroll the function you want to adjust Press to scroll the function you want to adjust Table 3 1 Panel Controls AUTO MENU ON OFF LCD PWR Figure 3 1 OSD Control Bar Controls Description AUTO Automatically size centers direction and fine tunes Video signal to eliminate noise and direction BRIGHTNESS Adjusts back ground black level of the screen image CONTRAST Adjusts for ground white level of the screen image SHARPNESS Adjusts the clarity and focus of the screen image H POSITION Moves the screen image left or right V POSITION Moves the screen up or down Adjusts image distortion appearing as vertical bars or noise CLOCK on the screen Adjusts image distortion appearing as horizontal noise on PHASE the screen COLOR Adjusts color temperatures for users METER Allows you to choose from among five languages as LANGUAGE a English French German Italia Simplified Chinese Unicorn series User s Manual Espanola and Nederland SPEAKER Volume control OSD Adjust operation of up down on the screen V P
17. onents Unicorn series User s Manual No Component Function Description 1 Handle Holder Pull to Slide the LCD console in or out 2 ILCD Display Panel Display 3 ILCD Panel OSD Buttons Controls Display Required Quality 4 LED Indicators Switching Operation for KVM Module Optional 5 Slide Rail Single Slide Rail 6 USB Ports x 2 K B Mouse Plug in external K B and Mouse 7 Power LED Indicates Power Status 8 PowerSwitch Turn on Turn off 9 Touch Pad Mouse Operation 10 Keyboard Module Keyboard Operation 11 LCD Lock Screws Fix or Release LCD panel 12 8 16 ports KVM Modular KVM for 8 16 ports Unicorn series User s Manual 2 4 Connecting the Console To connect an LCD console to a computer perform the following steps Ae CO CO 0 Co ojo 8 Port of KVM ee oe e o oo Jo eo oe eC Jo Se po 16 Port of KVM 1 Turn off your computer You should always turn off your computer before connecting or disconnecting a device 2 Connectthe video VGA connector of the KVM cable to the video card connector on the rear panel of your computer 3 Identify and connect the PS 2 mouse and PS 2 keyboard connector to the correct PS 2 ports on the rear panel of your computer Or you can use USB interface to connect your computer Use PS 2 USB switch to select your interface The switch has to be on PS 2 side when you use PS 2 i
18. r s Manual Auto Scan Mode You can start the OSD first and press F4 to enter the Auto Scan If you want to scan the PC you must use the Smart View Setting to select the Auto Scan Time in the System Setting for the residing time which includes 5 sec 10 sec 20 sec 30 sec and 60 sec You can adjust the Channel Display Mode and Channel Display Time from the Channel Display mode By then all keys on the panel keyboard and mouse are not operable You can only use the ESC key to exit the Auto Scan Mode Security Mode Switch the Security Level from None to Low in the System Setting and enter your Password A Z 0 9 a maximum of 12 characters and the security will be effective after you confirm the Password The use of the Console Lock Time is to set the time to enter a security mode after the keyboard and mouse has idled for a predetermined time Once you enter into the security mode you need to enter the correct password before you can move the mouse or enter any key from the keyboard You need a correct password to operate the whole system normally Important Note What should I do if forgot my Password After you enter a wrong password for 5 consecutive times a time delay bar will appear and a set of Magic Numbers will show up at the bottom Record the magic numbers and contact with your distributor Console Reconfirmed Simultaneously press the largest two numbered Port Selection Switches on the pan
19. ting the 0 enne nre entente nennen 8 pet ati Oia nemen MEM ILE 9 3 1 Panel Controls and LCD OSD 1 9 32 KVM OSD Funct ON 11 32 Key 11 3 2 2 Hot Key and Mouse Clicking 11 3 2 3 OSD On Screen Display 11 II 1 General Information The PLANET DKVM 1708 DKVM 1716 is the drawer KVM with single rail console design offering industrial level input solution which optimizes your space utilization by controlling your systems in just 1U space on the rack The separate rail design helps users install the KVM console more easily You don t have to prop the heavy console during the installation but just lock the rails into the rack and then pull the KVM console into the rails Simply use the supplied Combo VGA cable set to link the ports to the console ports of your KVM switch no matter whether your connected port interface be either USB or PS 2 The KVM switch modules are loaded with rich features such as one local console port Daisy chain capability On Screen Display OSD menu Password security Searching PC server name Hot key control Push button and Auto Scan control complete keyboard and mouse emulation for simultaneously PC boot up processes 1 1 Packing List The complete package consists of 1 8 m KVM cable HDB 15 VGA PS 2 x 2 a One 1 8m power cord One user s
20. urn on off the keys of the Mouse Clicking mouse for switching computer OFF ON functions Turn on off the beeper sound Beeper Sound E ON OFF function Set the offline skip function to Offline Skip Manual Auto auto or manual Francais Deutsch OSD Language Select the language for the OSD English Italiano Espanol Select the security mode and Security Level None Low High level C 1Min onsole Loc Time 1 The lock time of console port 5 Min 10Min 5 30Min 60Min 1 You can select this option only if the Security Level is not None F1 Information It provides the model name and F W version information which is helpful for users to understand the updated version F4 OSD Position you can enter the OSD position to make adjustments we recommend you to unify the resolution for all computer display mode and use this function again to adjust the OSD position You can use the Up Down Left or Right keys on the keyboard or a mouse to move the OSD position F8 Restore Default Setting Restore the factory default settings Please note that all name lists will be cleared and the system settings are set to the default settings as shown in the table above Esc Exit Exit the system setting and close the OSD If you have made changes in this option the system will ask whether or not you want to save the setting before the selected option is effective Unicorn series Use