Home

Trademarks FCC Warning CE Mark Warning REVISION

image

Contents

1. Trademarks Copyright PLANET Technology Corp 2004 Contents subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp The information in this manual is subject to change without notice All other trademarks belong to their respective owners FCC Warning This equipment has been tested and found to comply with the regulations for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class B product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures REVISION EM WFT20xv1 indd User s manual for PLANET Intelligent Media Converter For Models WFT 201 WFT 202 WFT 202S15 Rev 2 0 Nov 2004 Part No EM WFT20xv2 1 aD 2004 11 5 12 01 Table of Contents Chapter 1 INTRODUCTION 1 1 1 Overview of this User
2. The default Login name and password is both root 4 1 2 TELNET program setting The WFT 20x system can be accessible using TELNET through LAN 1 Run TELNET program 2 Enter the IP address 192 168 1 1 the factory default IP address setting 3 The default Login name and password are both root EM WFT20xv1 indd 7 aD 2004 11 5 12 01 z BB 4 1 3 Configure the Intelligent WFT 20x 4 1 3 1 Main Menu The main menu shows the setting of the File General Configuration System Configuration Device Configuration SNMP Configuration and Device Status File General Configuration System Configuration Device Configuration snmp Configuration Device Status 4 1 3 2 Files To set the Software Reboot Factory Reset and Image Update Software Reboot Factory Reset Image Update 4 1 3 2 1 Software Reboot After configuring the software you need to reboot the device by pressing the Software Reboot to change the setting 4 1 3 2 2 Factory Reset This function is to set the device back to the factory default setting in case of the messy setting 4 1 3 2 3 Image Update The section is to set the TFTP Server IP Address first and the default address was set to 192 168 1 2 The Image File can be updated by uploading the image file from the TFTP server TETP Server IP Address _ BRAS ie ETA Update File mcimage The content of the image file will write the whole fi
3. This page needs to configure the Copper and Fiber Setting 10 100T 100S X v1 0 Device Configuration Flow Control Enable Dup Copper Enable Full 1084 Enable ON Fiber Full Ait ito e Copper Setting to set the Auto Negotiation Mode Duplex mode Speed Flow Control and Link Enable setting e Auto Negotiation when set to Auto it will detect the speed from other end if it will be 10Mbps or 100Mbps and will set itself to be the same speed and when set to Force then it can be only set to 100Mbps or 10Mbps e Duplex Mode to set the device runs in Full Duplex mode or Half Duplex mode e Speed to set the device to run in speed of 10Mbps or 100Mbps e Flow Control to enable or disable to flow control of the device e Enable to enable or disable the linkage of the copper RJ45 e Fiber Setting to set the Duplex Mode of the Fiber to be Full duplex or Half duplex mode A After configuring the system device need to press the save NOTE button to save the setting 4 1 3 6 SNMP Configurations To set the SNMP setting on MIB Browser to monitor the device Get Community Name IE ET Set Community Name private Trap Community Name public Trap Host IP Address 192 168 1 2 Cold Start Trap Enable Warm Start Trap Enable Authentication Fail Trap Enable MC Link Up Trap Enable MC Link Down Trap Enable HC Broken Trap Enable e Get Community Name to ge
4. mode FDX COL 5 Lights Off link is in half duplex mode TP Fiber Blinks Green there is collision happens 100 Lights Green the link speed at 100Mbps Speed for TP Lights Off the link speed at 10Mbps Power Notice 1 The device is a power required device it means it will not work till it is powered If your networks should active all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from network data loss or network downtime 2 In some area installing a surge suppression device may also help to protect your switch from being damaged by unregulated surge or current to the media converter EM WFT20xv1 indd 6 aD 2004 11 5 12 01 is Chapter 4 Configure The Media Converter This chapter helps you how to configure the WFT 20x 4 1 Configure Through Terminal Emulator TELNET Program 4 1 1 Terminal Emulator program setting The WFT 20x can be accessed using a terminal or terminal emulator attached to the RS 232 serial port 1 Locate correct DB9 serial port cable with female DB9 connector 2 Attach the DB9 serial port female cable connector to the male DB9 serial port connector on the chassis system 3 Attach the other end of the DB9 serial port cable to a remote the workstation 4 By default the WFT 20x uses the following serial port parameter values Bits per second 57600 Stop bits 1 Data bits 8 Parity NONE Flow Control NONE
5. s Manual 1 Chapter 2 UNPACKING AND SETUP 2 1 Unpacking 3 2 2 Setup Chapter 3 IDENTIFYING EXTERNAL COMPONENTS 3 1 Front Panel 3 2 LED Indicators Chapter 4 CONFIGURE THE MEDIA CONVERTER 4 1 Configure Through Terminal Emulator TELNET Program 7 4 2 Configure Through Web browser 11 Chapter 5 SPECIFICATIONS 17 EM WFT20xv1 indd 2 eN 2004 11 5 00 12 01 E te Chapter 1 Introduction The Intelligent 10 100Base TX to 100Base FX Media Converter series WFT 20x support the conversion of different media between the copper Fast Ethernet 10 100Base TX and fiber Fast Ethernet 100Base FX The WFT 20x had built in Micro Processor to monitor the WFT 20x status and to configure the device s advanced function Through in band management via TELNET Web Browser and SNMP management utility or the out band management via RS 232 console to monitor the status The WFT 20x supports SNMP agent to advise the network manager while the device occur an abnormal 1 1 Overview of this User s Manual Introduction Describes the WFT 20x and its features Unpacking and Setup Helps you get started with the basic installation of the WFT 20x Identifying External Components Describes the front panel and LED indicators of the WFT 20x Configure The Media Converter Helps you how to configure the WFT 20x Technical Specifications Lists the technical general physical and environmental performance and Routers set
6. Consump oe 6 Watts maximum Dimensions 190 x 120 x 38 mm L x W x H Power Internal Power 100 240VAC Operating 0 C 40 C 32 F 104 F Temperature Storage 25 C 70 C 13 F 158 F Humidity 10 90 non condensing Emissions FCC Class B CE Marking Class B VCCI Class B 17 EM WFT20xv1 indd 17 aD 2004 11 5 12 01 18 EM WFT20xv1 indd This page is intentionally left blank 2004 11 5 12 01 EM WFT20xv1 indd 2004 11 5 12 01 E Part No EM WFT20xv2 EM WFT20xv1 indd CE 2004 11 5 12 01
7. a L Yv EM WFT20xv1 indd 12 2004 11 5 12 01 4 2 5 General Configuration This page is to configure the device name passwords and location General Configuration A 1 1 01 11 02 Factory Hardware revision noted the version of the hardware BIOS revision noted the version of the BIOS Firmware revision noted the version of the firmware e Change Password the changing of the administrator password e Confirm Password to confirm the setting of administrator password e System Name to authorize the device system name e Location to show the device where it is located 4 2 6 System Configuration This page is for setting or displaying the MAC Address IP Address Subnet Mask and Gateway Address System Configuration MAC Address 003047280 70 249 158 255 255 0 70 249 254 e MAC Address will show out the MAC address of the device IP Address to allocate an IP address for the device the default IP is 192 168 1 1 e Subnet Mask to set the Subnet Mask the default is 255 255 255 0 e Default Gateway to set the gateway address the default is 192 168 1 254 EM WFT20xv1 indd 13 13 2004 11 5 00 12 01 4 2 7 Device Configuration This page needs to configure the Copper and Fiber Setting 2 S C Half e Copper Setting to set the Auto Neg
8. hown followed by a description of each panel feature The indicator panel is described in detail in the next chapter 3 1 Front Panel The figure below shows the front panels of the WFT 20x PLANET 10 T00BASE TX to T00BASE FX LNKi FDR Console SYS FAIL ACT COL 100 PRRO O O Q O OTP eueodge RESET K f ga000c O CONSOLE Q O Q Fiber TX RN t ttt t LED Indicatr Console Port Reset Copper port Fiber port intelligent Media Converter e LED Indicator Panel Refer to the next section for detailed information e Console Port RS 232 To configure the device through Terminal Emulation Program via the RS 232 serial port e Reset To reset all the setting in case of messy setting e 10 100Base TX Twisted Pair Port The 10 100Mbps Fast Ethernet port supports automatic MDI MDIX crossover detection function gives true plug and play capability without the need of confusing crossover cables or crossover ports e Fiber Port To connect with fiber optic cable to the fiber port EM WFT20xv1 indd 5 aD 2004 11 5 12 01 3 2 LED Indicators ee Lights Amber power is inserted and it is fail System CPU Blinks Green the data is transmitting CONSOLE Blinks Amber transmitting the wrong data FAIL f Lights Amber the link is fail TP Fiber LNK ACT Lights Green when link to networking Ethernet TP Fiber Blinks Green when link is activity Lights Green link is in full duplex
9. oint the selections in the left side of the menu screen The menu includes System Reboot Factory Reset Image Update Device Status General Configuration System Configuration Device Configuration and SNMP Configuration and that to be explainde in the next section Intelligent Media Converter System Function System Configuration MAC Address 00304147 28 e0 11 EM WFT20xv1 indd 11 2004 11 5 12 01 4 2 1 System Reboot After configuring the converter you need to reboot the device by pressing the System Reboot to access the new setting Software Reboot 4 2 2 Factory Reset This function is to set the device back to the factory default setting in case of the messy setting Factory Reset Reset 4 2 3 Image Update This function allows you to update the firmware on the media converter Please first setup a TFTP server and copy the firmware file to the server s directory Enter the server s IP e on the TFTP Server IP section the firmware file name on Image File section then click Update to update the converter s firmware Please regularly check PLANET web site for any new available firmware TEESE a ie mageri mee The content of the image file will write the whole firmware of 2 NOTE the WFT 20x please be sure that the image file is correct 4 2 4 Device Status This page shows that the device s copper and fiber linking status a a OVO SUS _ eee x
10. otiation Mode Duplex mode Speed Flow Control and Link Enable setting e Auto Negotiation when set to Auto it will detect the speed from other end if it will be 10Mbps or 100Mbps and will set itself to be the same speed and when set to Force then it can be only set to 100Mbps or 10Mbps e Duplex Mode to set the device runs in Full Duplex mode or Half Duplex mode e Speed to set the device to run in speed of 10Mbps or 100Mbps e Flow Control to enable or disable the flow control of the device e Enable to enable or disable the linkage of the copper RJ45 e Fiber Setting to set the Duplex Mode of the Fiber to be Full duplex or Half duplex mode After configuring the system device need to press the save 2 NOTE button to save the setting 4 2 8 SNMP Configuration Configuring the SNMP setting on MIB Browser to monitor the device i ee Z Enable Disable Dan I gt Enable Disable Authentication Fail Trap Enable C Disable MC Broken Trap Enable Disable MC Link Up Trap MC Link Down Trap ic Enable Disable le Enable Disable e Get Community Name to get the device community name default public e Set Community Name to set the device community name default private e Trap Community Name to authorize the device trap community name default public e Trap Host IP Address to set the trap host IP address same as monito
11. ring station IP address 14 EM WFT20xv1 indd 14 2004 11 5 12 01 eg e Cold Start trap to set the trap for rebooting the device default enable e Authentication Fail Trap to set the warning trap when the community name of the device and workstation are different default enable e MC Link Up Trap to enable the trap that if other device has linked up e Warm Start Trap to enable a trap that if the device was restart e MC Broken Trap to enable the trap that announcing the WFT 20x was destruct e MC Link Down Trap to enable the trap that if the linked of the device was pulled down 15 EM WFT20xv1 indd 15 aD 2004 11 5 12 01 16 EM WFT20xv1 indd This page is intentionally left blank 2004 11 5 12 01 Chapter 5 SPECIFICATION IEEE802 3 10Base T Standards IEEE802 3u 100Base TX 100Base FX 1 x 10 100 Base TX port Ports 1 x 100 Base FX port 10 20Mbps for half full duplex Speed 100 200Mbps for half full duplex Unit Power System Console LED Indicators TP FAIL LINK ACT FDX COL 100M Fiber FAIL LINK ACT FDX COL 10Base T 2 pair UTP Cat 3 4 5 up to 100 m 328 ft 100Base TX 2 pair UTP Cat 5 up to 100 m 328 ft 100Base FX WFT 201 WFT 202 62 5 125um or 50 125um multi mode fiber optic up to 2km WFT 202S15 9 125um single mode fiber optic up to 15km Power
12. rmware 0 Note Of the management module please be sure that the image file is correct EM WFT20xv1 indd 8 aD 2004 11 5 12 01 i _______s 4 1 3 3 General Configurations This page is to configure the device name passwords and location Hardware revision Al BIOS revision 1 00 Firmware revision 1 00 Change Password Confirm Password System Name location e Hardware revision noted the version of the hardware e BIOS revision noted the version of the BIOS e Firmware revision noted the version of the firmware e Change Password the changing of the admit password e Confirm Password to confirm the setting of admit password e System Name to authorize the device system name e Location to show the device where it is located 4 1 3 4 System Configurations This page is for setting the MAC Address IP Address Subnet Mask and Gateway Address MAC Address 00 48 09 13 57 98 IP sce SEL72 16 2 12 Subnet Mask 255 255 0 0 Default GW 172 16 1 254 MAC Address will show out the MAC address of the device IP Address to allocate an IP address for the device the default IP is 192 168 1 1 e Subnet Mask to set the Subnet Mask the default is 255 255 255 0 e Default Gateway to set the gateway address the default is 192 168 1 254 EM WFT20xv1 indd 9 aD 2004 11 5 12 01 BB 4 1 3 5 Device Configurations
13. t the device community name default public e Set Community Name to set the device community name default private e Trap Community Name to authorize the device trap community name default public e Trap Host IP Address to set the trap host IP address same as monitoring station IP ad dress 10 EM WFT20xv1 indd 10 aD 2004 11 5 12 01 e Cold Start trap to set the trap for rebooting the device default enable e Authentication Fail Trap to set the warning trap when the community name of the device and workstation are different default enable e MC Link Up Trap to enable the trap that if other device has linked up e Warm Start Trap to enable a trap that if the device was restart e MC Broken Trap to enable the trap that announcing the WFT 20x was destruct e MC Link Down Trap to enable the trap that if the linked of the device was pulled down 4 1 3 7 Device Status This page shows that the device s copper and fiber linking status Link Speed Duplex Flow Contor Fail Copper Y 100H F V x F iber rad lal F 4 2 Configure Through Web browser 1 Open up the Internet Web browser 2 Enter the IP address http 192 168 1 1 the factory default IP address setting to the URL web address location 3 Enter the user name and password you have configured the default Login name and password are both root 4 The web configuration will be shown P
14. tings specifications of the WFT 20x EM WFT20xv1 indd 1 aD 2004 11 5 12 01 EM WFT20xv1 indd This page is intentionally left blank 2004 11 5 12 01 ii _ ___ lt _s Chapter 2 Unpacking and Setup This chapter provides unpacking and setup information for the WFT 20x 2 1 Unpacking Open the box of the WFT 20x and carefully unpack it The box should contain the following items e One Intelligent Media Converter e One Power Cord e One RS 232 Cable 9 pin female to 9 pin female e Rubber Feet e CD ROM e This User s Manual If any item is found missing or damaged please contact your local reseller for replacement 2 2 Setup The setup of the WFT 20x can be performed using the following steps e The power outlet should be within 1 82 meters 6 feet of the WFT 20x Converter e Visually inspect the AC power cord and make sure that it is fully secured to the de vice Make sure that there is proper heat dissipation from and adequate ventilation around the WFT 20x Do not place heavy objects on the WFT 20x EM WFT20xv1 indd 3 aD 2004 11 5 12 01 EM WFT20xv1 indd This page is intentionally left blank 2004 11 5 12 01 O O Chapter 3 Identifying External Components This section identifies all the major external components of the WFT 20x The front panel is s

Download Pdf Manuals

image

Related Search

Related Contents

Directive CT 02.020-35 Application des instructions d`entretien  Manuel d`installation Luna Gold+ Bois Français.indd - M  1 - ifm  User manual axm998 English Date: 05/2006  instruction manual - Juice-USA  Bil-jax 3632T Operator Manual  Samsung YUKON GLOBAL Combo with Eco Bubble, 14 kg User Manual  NM220G(E) Manual  wartungshandbuch manual de servicio manuel d`entretien service  Machine à voter - Mandelieu La Napoule  