         Contents
1.         1 The control unit is installed with the unlocked password  The user can enter his own password e g      1234     From this moment the important parameters cannot be altered without the password being  unlocked  that is  resetting the password    1234      After changing essential parameters the user can  leave the control unit unlocked  set any new password or enter    9999     which activates the password     1234       2  Producer gives the control unit with the set password  The user cannot alter the important  parameters  The servic can change the settings with its own secret password  At the end a serviceman  enter the secret password or    9999     the user still hasn t access to the important parameters     3  Producer gives the control unit with the set password  The user cannot alter the important  parameters  The servic can change the settings with its own secret password  At the end a serviceman  leaves the control unit unlocked  the user now has access to the important parameters  He can enter  his own password like in example No  1     4  Producer gives the control unit with the set password  The user cannot alter the important  parameters  The servic can change the settings with its own secret password  At the end a serviceman  sets the password e g     1234    and tells it to the user  the user has access to the important parameters  but without knowing the password the other persons cannot make the changes     5  The user has the unlocked control unit
2.  By clicking the CONFIRM  OK   button  5  one confirms the changes   the parameter field stops blinking  The changed parameter not  confirmed for 10 secs is not accepted by the control unit and it recalls a previous value of the  parameter   3 1 Screens  The alarm screen is not seen till the following emergency situation takes place    1  Damage of sensor T1     T Firep    shows up    2  Damage of internal temperature sensor of reference temperature    Ref  Temp  shows up    3  Exceeding CO concentration by shorting the terminal X1    Gas  shows up    4  The exceeding of the acceptable maximum temperature of the fireplace   T MAX  shows up           The alarm situation is accompanied by the status diode  7  blinking and a broken sound alarm  that can be turned off by pressing any button    The screen of the control unit status displays the preset fireplace power and the phase of the control    unit operation     lt             _ Fireplace power 1 2 3  F1    Phase of the optimizer operation       The fireplace power is set by pressing the Wbutton  4   On the display it corresponds to 1 2 or 3   Pressing the START button  2  opens up the air damper and the cycle start     The screen of the control unit operation displays the current temperature of the fireplace  opening  level of the air damper  phase of the control unit operation and possibly a combustion error        lt              Combustion temperature T1   or the blinking text  END     1200    The refuelling of the fuel i
3.  CHOOSE        Fig 2 View of control panel    Text display   Button to increase the value    A     or START    Button to choose the parameter      Button to lower the value   W     or STOP    Button to confirm the changes   OK    or AUTO    Button to enable the manual mode W  MAN    Status diode of the control unit  alarm  red   standby  green     Diode of the combustion cycle  green   Diode of the air damper operation  blinking means the overload of the drive    22  OSS  i a a       4       WANA    PRODUCENT ZASILACZY SIECIOWYCH    ISO 9001  2000    CE CONFORMITY DECLARATION  Ref  No  58 RT 01 2007 1 B    We  ZAKLAD ELEKTRONICZNY TATAREK Jerzy Tatarek  75 Swieradowska St    50 559 Wroclaw    declare under our sole responsibility that  the following control unit  FIREPLACE POWER OPTIMIZER  model  RT 080M  is in conformity with the basic requirements included in Directive EMC 2004 108 WE of 15 12 2004  the  electromagnetic compatibility law of 13 04 07  and Directive LVD 2006 95 WE of 21 08 07  Laws Journal  of 2007 No  155 pos  1098  regarding the requirements for electric devices     To the conformity evaluation the following harmonized standards were used     PN EN 60730 2 1  2002   Automatic electric control units for house usage and the like  Part 2 1   Specific requirements regarding electric control units for electric house  devices   Automatic electric control units for house usage and the like    Part 1  General requirements     PN EN 60730 1  2002      PN EN 55022  2
4.  of water in the cap  Because of high  temperature maintaining close to the water cap and coming  from that both a risk of damaging the sensor and false  measurements of temperature  its assembly should be carried  out on the pipe channelling water from the water cap  beyond the fireplace      gt   W  zZ     I  oO       Fig l Basic operation scheme of the optimizer    Tl Temperature sensor of the combustion  D1 Sensor of opening the furnace door  option   PP Controlled air damper    2 1 Operation phases of the control unit  The optimizer controls the combustion process as a cycle of the following phases    1  F0 STOP   Standby phase  The control unit awaits opening the door and preparing the  fuel for the next heating  FO is a temporary state to STOP  In the STOP state the air  damper is closed    2  F1   Start phase  After loading the fuel and its lighting you close the furnace door  It s a  signal for the control unit that the combustion cycle has begun  The air damper is fully  open    3  F2   Heating up phase  After reaching the limit temperature and warming up the  fireplace the pass to the phase F3 follows    4  F3  Burning combustion phase  Stabilization of combustion temperature depending on   the chosen power of the fireplace   F4   Phase of decreasing temperature  The air damper is again gradually closed   F5   Embers phase  Signalling the demand for replenishing the fuel   6  F6   Phase of removing the furnace gases  The air damper first opens up and then closes  a
5.  or his own password  Serviceman decides  the user though  oughtn t have access to the important parameters  The serviceman locks the control unit with his  secret password  which removes the user s password and locks the control unit     6  Serviceman doesn t have to know the user s password  Always he can use his own secret  password and at the end lock with the    9999     which reactivates the user s password     
6. 000   Electromagnetic compatibility  EMC   IT devices  Characteristics of radioelectric noises  Acceptable levels and measurement methods    Complementary information   Laboratory  ASE 51 618 Wroclaw  1 Wystawowa st     Test report No  39 DL I 07 of 22 06 2007  41 DL 1 07 of 03 07 2007    Electronic Engineering Plant TATAREK  has initiated management system and complies with the following standard    1SO9001  2000 CERTIFICATE No  133 2004 of 01 2004  Polish Foreign Trade Chamber    The last two digits of the year in which the CE marking was affixed  07    Place of issue  Manufacturer representative     Wroclaw Miros  aw Zasepa  Mase nm  Date of issue  Position   08 2007 Konstruktor    WARRANTY    1 Warranty is valid  24  months from the date of sale    2 Producer does not take responsibility for any mechanical damages made by user   3 MAKING REPAIRS OR MODYFYING THE DEVICE BY USER IS   FORBIDDEN AND CAUSES WARRANTY CANCELATION   4 Warranty card is valid only with date of sale  seller s signature and stamp  5 Warranty and after warranty repairs should be done only by producer  damaged  regulators should be sent to producer in order to make all repairs needed   6 Warranty protection includes the EU   7 Warranty does not exclude  not restrict and not suspend buyer   s rights coming from  the incompatibility of the article with the agreement  Laws Journal No  141 Pos  1176     WARNING     ANY MODIFICATION OF THE CONTROL UNIT MADE BY A USER CAN  BE THE CAUSE OF SAFETY CONDITIONS D
7. AT THE UNLOCKED PASSWORD    NAME RANGE   DEFAULT FUNCTION    The serial number of the control unit  The parameters set of the control  unit  Currently there s available 1 set   the standard one  The serial  number can be changed only at the unlocked password             NoProd Standard Standard          RESET Setting the value to   ON    causes the recall of all parameters to  OFF ON OFF their default pre sets and restarts the control unit  The reset can  be performed only at the unlocked password     0000    PASSWORD OFF          PASSWORD ON         After entering the wrong password the restart follows       PASSWORD   0   9999                         Password  The changes of important parameters are possible only at the unlocked password  To unlock the    password you need to input proper sequence of digits with the buttons    A W     With the button     to change the digits position and OK button  6  to acknowledge all and finish the procedure    of changing the password  The unlocked password is set to    0000     Once again entering into the  password change procedure causes a new password to be set          s           PASSWORD   9999    HAS CONSIDERABLE MEANING  IT CAUSES THE  REACTIVATION OF THE PREVIOUS PASSWORD IF PRESENT WITHOUT IT BEING    EXPOSED     PASSWORD OF PRODUCER S SERVICE IS UNIQUE AND IS NOT DEPENDENT ON THE    USER S PASSWORD  IT SHOUDN T BE EXPOSED TO THE USER  INSTEAD OF THAT    THE SERVICE CAN SET TO THE USER HIS OWN PASSWORD   Examples of passwords
8. ETERIORATION AND CAN  EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES  SUPPLIED     Connection cable of the control may be replaced only  by producer or his authorized service locations    WARNING   1  Producer does not take the responsibility for damage    caused by atmospheric discharge  2  and overvoltage in the mains  3  Burnt fuses are not subject to warranty replacement       Date of sale Seller s signature and stamp    ARGO FILM  Recycling Plant No  6  180 Krakowska st   52 015 Wroclaw    Register No   GIOS  E 0002240WZ    Worn out electronic    the utilization collection place  where will 0 515 122 142    be accepted for free    and electric devices must be transfered to Ph   071 794 43 01  yd       a     TNS  a   Zaktad elektroniczny TATAREK Jerzy Tatarek  50 559 Wroclaw  75 Swieradowska st  ph   071  367 21 67  373 14 88  fax 373 14 58  tax index number 899 020 21 48   Bank account   BZ WBK S A  O WROCLAW 6910901522 0000 0000 5201 9335  www tatarek com pl   E mail  tatarek tatarek com pl       The operation state is presented on the text display  1   The screens inform about the operation of  devices  temperature of the furnace  they make it possible to change the parameters etc   The change  of screen is done by pressing the CHOOSE button  9  3   If this is the screen that is able to change a  parameter  press the CONFIRM button 5  OK  which causes blinking of the parameter field to be  changed  By pressing            2  or     V     4  one can alter its value 
9. INAS    Zak  ad elektroniczny TATAREK Jerzy Tatarek    50 559 Wroclaw  75 Swieradowska st   ph   071  367 21 67  373 14 88  fax 373 14 58  Tax index number 899 020 21 48   Bank account  BZ WBK S A  WROCLAW 6910901522 0000 0000 5201 9335  www tatarek com pl   E mail  tatarek tatarek com pl    6             TANINI       RT080M 2012 v 1 0 ANG    Zak  ad elektroniczny TATAREK Jerzy Tatarek    USER MANUAL    v 1 0  21 02 2011 software 1v0     FIREPLACE OM FIREPLACE       POWER OPTIMIZER  RT 080M       1 Basic technical parameters    Power 230V 50Hz   Auxiliary power Rechargeable battery 4 8V 60mAh  Power consumption without load SW   Max connection power 250W   Operation conditions 0 40  C  humidity 10 90     no condensation  Housing protection class IP41  Fuse 6 3A 250V  1   contact NO and NC     normally closed and open contact     Number of nonvoltage control outputs    Number of outputs to control the air damper drive 1   5V 500mA DC   Number of temperature sensors 1   Thermocouple type K  0    1300  C    Temperature measurement precision 5  C   Temperature measurement resolution 1  C               2  Principle of operation    The RT 080M control unit is used to control the combustion process and maintaining the embers  phase as longas possible by controlling the air damper that channels air to the combustion chamber   Thanks to lowering the combustion curve during the phase of temperature increase and its raising  during the phase of temperature decrease the control unit exte
10. Restar 10   1250  C 45  C Restart temperature after switching on     If after switching on the control unit the temperature  in the furnace is higher than  T Restar  then  automatic start follows   Ti STOP 0   600secs 120secs After this time the transition to the standby phase   STOP  takes place if the temperature  T Restar   is not reached   T F2 50   1250  C 400  C End temperature of the heating up phase  T F3 1 50   1250  C 250  C Temperature of the phase F3 at power 1  T F3 2 50   1250   C 300  C Temperature of the phase F3 at power 2  T F3 3 50   1250   C 350  C Temperature of the phase F3 at power 3  dT F3 10   200  C 50  C Maximum temperature increase in the phase F3  dT F3  F4  10    300   C  30  C Temperature drop in relation to F3 starting the phase F4  Ti F4 1   10 mins 2 mins Time span of the condition  DT F3 F4  required for  finishing F3 and going to F4  T F5 50   1250  C 150  C Start temperature of the phase F5  Ti F5 1   60 mins 5 mins Period of the phase F5  Ti PDM 0   10 mins 1 mins Period of the phase F6  Scavenge time   Opening the air damper and burning out furnace gas  Phi F3 1 0   100   60   Maximum opening of the air damper of the phase F3  at power 1  Phi F3 2 0   100   65   Maximum opening of the air damper of the phase F      at power 2  Phi F3 3 0   100   70   Maximum opening of the air damper of the phase F3  at power 3  Plo F3 1 0   100   10   Minimal opening of the air damper of the phase F3  at power 1  Plo F3 2 0   100   10   Minimal opening 
11. as higher potential  it s important for  Open Collector Systems   Schort circuit of the contacts means the exceeding of permitted CO  concentration  At the lack of CO control you leave the contacts not connected    Sensor of opening the furnace door  At the closed door the terminal D1 should be opened see Fig     At the opened door the terminal D1 should be short circuited     Sensor of combustion temperature  Thermocouple type K  the wire of higher potential is green  of lower  one is white           4 Mounting the RT 080m control unit      THE CONTROL UNIT IS SUPPLIED WITH 230V 50HZ    ANY MOVES REGARDING THE INSTALLATION SHOULD BE MADE AT    THE DISCONNECTED MAINS            THE CONTROL UNIT HAS TO BE CONNECTED TO THE MAINS WITH THE    ZERO PIN CABLE THROUGH THE DIFFERENTIAL  DEVICE THAT CUTS OFF  THE POWER ACCORDING TO THE REGULATIONS         THE PRODUCER DOESN T TAKE ANY RESPONSIBILITY FOR BOTH  DAMAGES CAUSED BY WRONG USAGE OR FAULTY MOUNTING OF THE  CONTROL UNIT AND ITS USAGE NOT IN ACCORDANCE  WITH ITS PURPOSE              10                PARAMETRS OF LEVEL 1                                                                                                                NAME RANGE DEFAULT   SETTING FUNCTION  Signal OFF ON ON Switch on Switch off of the sound alarms  PARAMETERS OF LEVEL 2  THE PARAMETERS CAN BE ALTERED AT THE UNLOCKED PASSWORD  NAME RANGE DEFAULT SETTING FUNCTION  DelayTim 15   600secs 60secs Delay of the control unit start  period of the phase F1   T 
12. nd there s the pass to the standby phase     m    2 2 Power of the fireplace  The user himself decides about the heating power of the fireplace     There re 3 power levels  1 minimum  2 3 max  with which the corresponding parameters of the  burning phase F3 are connected     2 3 Air damper  The air damper regulates air inflow to the combustion chamber dependent on the phase     During the flap move of the air damper the diode  9  lights  The blinking means a temporary  overload of the drive affected by met resistances     2 4 Additional functions of the control unit  The main function of the RT 080m control unit is optimizing the combustion process via the control  of air inflow into the combustion chamber realized through the air damper     Additionally    lAn external device controlling CO concentration can be connected to the control unit  In case of  detecting the danger the air damper  PP  opens up improving the ventilation ofroom  additionally the  signal alarm switches on      The control unit switches on the ALARM output in case of damage of the temperature sensor of the  furnace  T1  or exceeding of CO concentration     3 Operating the control unit   On the control panel  Fig 2  are the control elements of the control unit  In the standby state the green  control diode  7  of the standby state lights  Turning on the control unit occurs after opening the  furnace door  The closing of the door starts the combustion cycle  which is indicated by the green  diode  8      
13. nds the combustion process    The most important advantage of this model of the optimizer is the capability to choose one of 3  programs for operation power of the input depending on the user s needs and maintaining as  long as possible the chosen range of the operation  Thanks to that it s possible to achieve out of a  given portion of fuel an optimal portion of energy  which allows to raise functionality economy  of the fireplace or stove  to which the RT 080m control unit has been applied    The operation of the RT 080m optimizer control unit begins at the moment that the furnace door  closes  the sensor of opening the door D1  or in case of no sensor with the START button on the front  control panel  The combustion process starts controlled by the furnace gas temperature sensor that  manages the air damper which supplies air to the furnace  At the time of a systematic decrease of  temperature  burning out the input  the air damper is being closed  When the embers phase in the  furnace is reached the air supply is cut off  interrupted by scavenges in order to get rid of waste gas  from the combustion chamber  In alarm situations  also power declines  the air damper is opened that  enables the full burnout of the fuel input  The special input to cooperate with an external CO detection  sensor improves the safety of using the fireplace     The control unit is equipped with its own emergency power supply  The pause in power supply  up to 8secs doesn t affect the control unit 
14. ng the cycle  Before  opening the door the air damper should also be opened by pressing    START    2  or passing to the  MAN mode  After lighting the fuel and closing the door you must again press    START     2  or     AUTO     5  ifthe control unit is in the manual mode    MAN          In the MAN mode you must not close the air damper completely before reaching  the embers phase because there can be a dangerously increased concentration of CO     poisonous carbon monoxide               The screen of setting the parameters    Menu  0    Normally the level of parameter setting  Menu  equals to    0     which means the parameters  aren   t available    After changing the level  Menu  to    1        2      or  3  the successive screens show the values of  parameters    The last screen contains            after which it comes back to the above mentioned screens        I  THEPARAMETERS ADAPT THE CONTROL UNIT TO THE PROPERTIES  OF THE FIREPLACE  THEIR CHANGE SHOULD BE CONSULTED WITH    THE PRODUCER OF THE FIREPLACE  INCAUTIOUS CHANGES CAN CAUSE  UNSTABLE AND INEFFICIENT OPERATION OF THE SYSTEM                CHIMNEY    FIREPLACE    PP    PP    Air damper  vege  STER YELLOW BLUE a  GND tack         e  n    Door sensor    ALARM     WHITE  y GREEN x3  T1 Alarm CO                                     L MAINS  i 230V 50Hz       Fig 3A Wiring scheme    PP  X3    D1    T1    Electronically controlled air damper    Input to connect a control device of CO concentration  The input         h
15. of the air damper of the phase F3  at power 2  Plo F3 3 0   100   10  Minimal opening of the air damper of the phase F3  at power 3  P F5 0   100   5  Opening level of the air damper at the start of F5  TypChoke Vind 2 Control type of the air damper                      1   Continuous control   servomotor of the  air damper always active       2  Dynamic control   servomotor of the air damper  active only if a position change of the air damper  is needed                       PARAMETERS OF LEVEL 3  PARAMETERS CAN BE CHANGED ONLY AT THE UNLOCKED PASSWORD       NAME RANGE DEFAULT FUNCTION                            Manual OFF ON ON Switching ON  OFF the manual mode  Manual    that is  switching off automatics  The controlling    of the air damper opening from the keyboard                Demonstration change of the  Manual  parameter  Parameters level 3   Press    repeatedly button  9  3  till the  Menu  parameter setting screen appears      OK    button  5   gt   0    starts blinking    threefold button            2   gt    3    blinks     OK    button  5   gt    3    stops blinking  Parameters level 3 was chosen     repeatedly D  3    gt      Manual    shows up actual value       OK    button  5     gt  actual value to be changed begins blinking     A V    gt  setting a new value      OK    button  5    gt  confirming the new value    repeatedly 49  3  button till the          parameter end setting screen appears           PARAMETERS OF LEVEL 4  PARAMETERS CAN BE CHANGED ONLY 
16. operation because during that time the buffer power  supply switches on  e g  A200WAC TATAREK   If the pause is longer the air damper opens up  in emergency before the optimizer control unit switches off     Advantages of the combustion optimizer     limiting the maximum combustion temperature    capability of choosing optimal fireplace power for the user    extending the combustion process    decreasing fuel consumption    extending the exploitation time of fireplace inputs    shutting off air supply after ending the combustion  preventing the furnace cool off    cooperation with CO sensors  opening up the fresh airing of the combustion chamber in  emergency           2          Admission  date    Realization  date    Signature    Remarks                                                                                           WARNING     WE INFORM THAT THE OFFERED CONTROL UNIT  CAN BE ONLY APPLIED TO THE FITTING DEVICES    THE REQUIREMENTS OF THE TECHNICAL AND BUILDING  STANDARDS CONCERNING THE CORRECTNESS OF STOVE   FITTER AND HEATING  SYSTEMS HANDLING THE FIREPLACE INPUTS MUST BE  MET    WRONG USAGE OF THE CONTROL UNIT CAN LEAD BOTH TO  ITS DAMAGE AND IN EXTREME CASES TO THE DAMAGE OF  THE FIREPLACE INPUT AND HEATING SYSTEM CONTROLLED  BY THE FIREPLACE AS WELL  ALONG WITH THE DEVICES  THAT COOPERATE WITH THE HEATING SYSTEM     CAUTION      We inform that in case of systems based on the water cap you  should pay attention to the location of mounting the  temperature sensor
17. s required   F1 50    e            _ Opening level of the air damper    Phase of the optimizer operation       5       Reaching the embers phase F7 is accompanied by a broken sound signal  switch off with the button   6     text    FuelOUT    and blinking of the green diode  8   which indicates the need for replenishing  the fuel in case of continuing the burning    Thecontrol unit can run in the automatic or manual mode  The longer pressing    MAN    4  6  about  2secs causes the pass to the manual mode  That s signalled by blinking status diode  7   The air    damper opens 100   From now on you can manually control the air damper      W     4  causes the    shutting  one step 10   and            2  the opening  The comeback to the automatic mode occurs after  pressing    AUTO     5        The transition to the manual mode  MAN  can be blocked if the parameter of level 3   Manual  is set to WY       In the automatic mode each opening of the door causes the air damper to be set at 100  and each  shutting ofthe door causes the combustion process started and the diode  8  lights    Ifthe furnace is cold then after the time    DelayTim Ti STOP     see parameters of level 2  the control  unit closes the air damper and passes to the standby state    Likewise the control unit acts when the power is switched on     During the operation without the sensor of opening the door the panel buttons are used for  controlling  Pressing    START     2  causes opening the air damper and starti
    