Home

Manual

image

Contents

1. 251 342 2164 FAX 251 342 6353 Website www n tron com Email N TRON_ Support n tron com Revised 9 23 2009 GENERAL SAFETY WARNINGS WARNING Do not operate the equipment in the presence of flammable gasses or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard WARNING If the equipment is used in the manner not specified by N TRON Corp the protection provided by the equipment may be impaired WARNING Do not perform any services on the unit unless qualified to do so Do not substitute unauthorized parts or make unauthorized modifications to the unit WARNING Do not operate the unit with the end plates removed as this could create a shock or fire hazard WARNING Do not operate the equipment in a manner not specified by this manual ENVIRONMENTAL SAFETY WARNINGS WARNING Disconnect the power and allow to cool 5 minutes before touching ELECTRICAL SAFETY WARNINGS WARNING Disconnect the power cable before removing the end plates WARNING Do not operate the unit with the end plates removed WARNING Do not work on equipment or cables during periods of lightning activity WARNING Do not perform any services on the unit unless qualified to do so WARNING Observe proper DC Voltage polarity when installing power input cables Reversing voltage polarity can cause permanent damage to the unit and void the warranty Revised 9 23 2009 HAZARDOUS LOCATION
2. MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED N TRON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS N TRON SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO OPEN REPAIR OR MODIFY THE PRODUCT OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING POWER CUTS OR OUTAGES OTHER HAZARDS OR ACTS OF GOD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW N TRON ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS LOSS OF INFORMATION OR DATA OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF N TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE
3. Operating Altitude 0 to 10 000 ft Network Media 10BaseT gt Cat 3 Cable 100BaseT gt Cat 5 Cable 100BaseFX Multimode 50 62 5 125um Fiber Singlemode 7 10 125um Fiber Fiber Transceiver Characteristics Fiber Length 2km 15km 40km 8Okm TX Power Min Max 19dBm 14dBm 15dBm 7dBm 5dBm 0dBm _ 5dBm 0dBm RX Sensitivity Max 32dBm 34dBm 34dBm 34dBm Wavelength 1310nm 1310nm 1310nm 1550nm Multimode Singlemode Connectors 10 100BaseTX RJ45 UTP Port 100BaseFX SC or ST Duplex Port Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 5 12 7 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 9 23 2009 Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2000 US and Canada This apparatus is suitable for use in Class I Div 2 Groups A B C D T5 EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified Revised 9 23 2009 104TX 105TX KEY SPECIFICATIONS Physical Height Width Depth Weight DIN Rail Electrical Input Voltage Input Current Inrush Current Input Ripple Input Wire Size Environmental Operating Temperature Storage Temperature
4. PAID AT N TRON S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE DISCLAIMER Some countries states or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for personal injury so the above limitations and exclusions may be limited in their application to you When the implied warranties are not allowed to be excluded in their entirety they will be limited to the duration of the applicable written warranty This warranty gives you specific legal rights which may vary depending on local law GOVERNING LAW This Limited Warranty shall be governed by the laws of the State of Alabama U S A Revised 9 23 2009 25
5. item is received by N TRON The repaired or replaced item will be shipped to the customer at N TRON s expense not later than thirty 30 days after N TRON receives the product N TRON shall not be responsible for any software firmware information or memory date of customer contained in stored on or integrated with any products returned to N TRON for repair whether under warranty or not ADVANCE REPLACEMENT OPTION Upon registration this product qualifies for advance replacement A replacement product will be shipped within three 3 days after verification by N TRON that the product is considered defective The shipment of advance replacement products is subject to local legal requirements and may not be available in all locations When an advance replacement is provided and customer fails to return the original product to N TRON within fifteen 15 days after shipment of the replacement N TRON will charge customer for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF
6. 3 5 8 89cm 1 49 3 78cm 3 53 8 96cm 0 7 Ibs 0 31kg 35 mm 10 30 VDC Regulated 10 60 VDC Regulated 250 mA max 24VDC Steady State 8 1 Amp 0 7ms max 24VDC Less than 100 mV 16 28 AWG 40 C to 70 C 40 C to 85 C 10 to 95 Non Condensing 0 to 10 000 ft gt Cat 3 Cable gt Cat 5 Cable Eight 8 RJ45 UTP Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 9 23 2009 21 Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2000 US and Canada This apparatus is suitable for use in Class I Div 2 Groups A B C D T4A The high voltage model is TUV approved GS per EN 60950 1 EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified Revised 9 23 2009 22 105FX KEY SPECIFICATIONS Physical Height 3 83 9 72cm Width 1 49 3 78cm Depth 3 53 8 96cm Weight 0 6 Ibs 0 27kg DIN Rail 35 mm Electrical Input Voltage 10 30 VDC Regulated Input Current 270mA max 24VDC Steady State Inrush Current 8 0Amp 0 7 ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environment
7. 83 9 73cm 1 50 3 81cm 4 80 12 2cm 0 6 Ibs 0 27kg 35 mm 10 30 VDC Regulated 270 mA max 24VDC Steady State 8 0 Amp 0 7ms max 24VDC 40 C to 70 C 40 C to 85 C 10 to 95 Non Condensing 0 to 10 000 ft gt Cat 3 Cable gt Cat 5 Cable 50 62 5 125um 7 10 125um Four 4 RJ 45 TX Ports Two 2 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 5 12 7 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 9 23 2009 Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2000 US and Canada This apparatus is suitable for use in Class I Div 2 Groups A B C D or non hazardous locations only T4A EMI IEC61000 6 2 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances EN61000 4 11 Voltage Dips and Interruptions GOST R Certified Revised 9 23 2009 20 108TX KEY SPECIFICATIONS Physical Height Width Depth Weight DIN Rail Electrical Input Voltage HV option Input Current Inrush Current Input Ripple Input Wire Size Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseT Connectors 10 100BaseT
8. INSTALLATION REQUIREMENTS This equipment is suitable for use in Class I Div 2 Groups A B C and D or unclassified or non hazardous locations only WARNING Explosion Hazard Substitution of components may impair suitability for Class I Division 2 WARNING Explosion hazard do not disconnect while the circuit is live or unless the area is known to be non hazardous WARNING Explosion Hazard Do not remove or replace the device unless power has been switched off or the area is known to be non hazardous Use 60 75 C rated Copper wire 0 22Nm 2 inch lbs Tightening torque for field installed connectors WARNING Install only in accordance with Local amp National Codes of Authorities Having Jurisdiction Class I Div 2 Installations require that power connections must be current limited at the power source with an in line fuse rated at 0 5A Class I Div 2 installations require that all devices connected to this product must be UL listed for the area in which it is installed Limited Operating Voltage 12 30V for Class I Div 2 installations Revised 9 23 2009 5 100 Series Industrial Ethernet Switches The 100 Series Unmanaged Industrial Ethernet Switches support high speed layer 2 switching between ports This series of switches are housed in a ruggedized aluminum enclosure and provide Category 5 compliant 10 100 BaseT connections for high performance network design and hub repeater upgrades All fiber product
9. Instruction Sheet Contact your carrier if any items are damaged UNPACKING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warning before beginning the installation WARNING Never install or work on electrical equipment or cabling during periods of lightning activity Never connect or disconnect power when hazardous gasses are present LASER SAFETY MCE and FXE models only 40 and 80 CAUTION CLASS 1 LASER PRODUCT Do not stare into the laser Revised 9 23 2009 DIN Rail Mounting Install the unit in a standard DIN rail Recess the unit to allow at least 2 of horizontal clearance for CATSe cable bend radius s To install the unit to 35mm industrial DIN rail place the top edge of the included mounting bracket on the back of the unit against the DIN rail at a 15 angle as shown Rotate the bottom of the unit to the back away from you until it snaps into place Most N Tron products are designed to be mounted on industry standard 35mm DIN rail However DIN rail mounting may not be suitable for all applications Our Universal Rack Mount Kit P N URMK may be used to mount the Revised 9 23 2009 To remove the unit from the 35mm industrial DIN rail place a flat head screwdriver into the release clip found at the bottom of the unit and apply d
10. Operating Humidity Operating Altitude Network Media 10BaseT 100BaseT Connectors 10 100BaseT RJ45 UTP Ports 2 87 7 28cm 1 49 3 78cm 3 53 8 96cm 0 6 Ibs 0 27kg 35 mm 10 30 VDC Regulated 215 mA max 24VDC Steady State 7 8 Amp 0 7ms max 24VDC Less than 100 mV 16 28 AWG 40 C to 80 C 40 C to 85 C 10 to 95 Non Condensing 0 to 10 000 ft gt Cat 3 Cable gt Cat 5 Cable Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 9 23 2009 Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2000 US and Canada This apparatus is suitable for use in Class I Div 2 Groups A B C D T4A EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified Revised 9 23 2009 106FX FX2 KEY SPECIFICATIONS Physical Height Width Depth Weight DIN Rail Electrical Input Voltage Input Current Inrush Current Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseTX 100BaseFX Multimode Singlemode Connectors 10 100BaseTX 100BaseFX 3
11. THE INDUSTRIAL NETWORK COMPANY 100 Series Media Converter amp Industrial Ethernet Switches User Manual amp Installation Guide Revised 9 23 2009 N TRON THE INDUSTRIAL NETWORK COMPANY Industrial Media Converter Installation Guide 102MC XX 102MCE XX YY 104TX 105TX 105FX XX 105FXE XX YY 106FX2 108TX 108TX HV Where XX ST or SC and YY 15 40 or 80 Revised 9 23 2009 Copyright N TRON Corp 2008 820 S University Blvd Suite 4E Mobile AL USA 36609 All rights reserved Reproduction adaptation or translation without prior written permission from N TRON Corp is prohibited except as allowed under copyright laws Ethernet is a registered trademark of Xerox Corporation All other product names company names logos or other designations mentioned herein are trademarks of their respective owners The information contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein Contact Information N TRON Corp 820 South University Blvd Suite 4E Mobile AL 36609 TEL
12. al Operating Temperature 40 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT gt Cat 3 Cable 100BaseT gt Cat 5 Cable 100BaseFX Multimode 50 62 5 125um Fiber Singlemode 7 10 125um Fiber Fiber Transceiver Characteristics Fiber Length 2km 15km 40km 80km TX Power Min Max 19dBm 14dBm 15dBm 7dBm 5dBm 0dBm _ 5dBm 0dBm RX Sensitivity Max 32dBm 34dBm 34dBm 34dBm Wavelength 1310nm 1310nm 1310nm 1550nm Multimode Singlemode Connectors 10 100BaseTX RJ45 UTP Port 100BaseFX SC or ST Duplex Port Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 5 12 7 cm Warranty Effective January 1 2008 all N TRON products carry a 3 year warranty from the date of purchase Revised 9 23 2009 Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2000 US and Canada This apparatus is listed for use in Class I Div 2 Groups A B C D T4A EMI EN 61000 6 4 EN 55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN 61000 6 2 IEC 61000 4 2 ESD IEC 61000 4 3 RS IEC 61000 4 4 EFT IEC 61000 4 5 Surge IEC 61000 4 6 Conducted Disturbances GOST R Certified Revised 9 23 2009 24 N TRON Limited Warranty N TRON Corp warrants to the end user that this hardware product will be f
13. e INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Cet appareillage num rique de la classe A r pond toutes les exigences de l interf rence canadienne causant des r glements d quipement L op ration est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interf rence re ue y compris l interf rence qui peut causer l op ration peu d sir e Revised 9 23 2009 14 102MC MCE KEY SPECIFICATIONS Physical Height 2 87 7 28cm Width 1 49 3 78cm Depth 3 53 8 96cm Weight 0 5 Ibs 0 22 kg DIN Rail 35 mm Electrical Input Voltage 10 30 VDC Regulated Input Current 140mA max 24VDC Steady State Inrush Current 8 5Amp 0 7 ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing
14. ownward force on the clip until it disengages from the bottom of the unit from the DIN rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle to completely remove the unit 100 Series enclosures to standard 19 racks as an option FRONT PANEL a a E O namo O NIRAN E NITRON 105EX 108TX warren 702MC O 7057X He 10 100 BaseTX 5 F6 Lk i 3 4 100 BaseFX TX JY From Top to Bottom SPD Speed LED LNK ACT Link Activity LED RJ45 Ports Auto sensing 10 100BaseT Connection 0 Green LED lights when Power is connected NOTE The top LED indicates Link Activity LNK ACT and the lower LED indicates Speed SPD status LED s The table below describes the operating modes LED Color Description D ON Power is Applied OFF Power is OFF ON Link established no Activity on cable LNK ACT BLINKING Link established Activity on cable OFF No link activity on cable ON LINK is 100Mbps SPD OFF Link is 10Mbs Revised 9 23 2009 9 APPLYING POWER Top View CHASSIS GROUND gt V Negative GND Return V Positive 10 30VDC Vi Negative GND Return V Positive 10 30VDC DETAIL Unscrew amp Remove the DC Voltage Input Plug from the top header Install the DC Powe
15. r Cables into the Plug observing polarity on unit Plug the Voltage Input Plug back into the top header Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot All LED s will flash ON Momentarily Verify the Power LED stays ON GREEN Note Either V or V2 can be connected to power for minimal operation For redundant power operation V and V2 plugs must be connected to separate DC Voltage sources Use wire sizes of 16 28 gauge The power cord should be limited to less than 10 meters in order to ensure optimum performance Recommended 24V DC Power Supplies similar to 100 240VAC N Tron NTPS 24 1 3 DC 24V 1 3A NOTE Not appropriate for use with M12 POE and HV models Revised 9 23 2009 10 N TRON SWITCH GROUNDING TECHNIQUES FOR 100 SERIES The grounding philosophy of any control system is an integral part of the design N Tron switches are designed to be grounded but the user has been given the flexibility to float the switch when required The best noise immunity and emissions i e CE are obtained when the N Tron switch chassis is connected to earth ground via a drain wire Some N Tron switches have metal din rail brackets that can ground the switch if the din rail is grounded In some cases N Tron switches with metal brackets can be supplied with optional plastic brackets if isolation is required Users may run a drain wire amp lug from the screw provided on the back face of the enclosure In
16. ree from defects in workmanship and materials under normal use and service for the applicable warranty period from the date of purchase from N TRON or its authorized reseller If a product does not operate as warranted during the applicable warranty period N TRON shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of N TRON Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the remainder of the initial warranty period whichever is longer N TRON shall not be responsible for any custom software or firmware configuration information or memory data of customer contained in stored on or integrated with any products returned to N TRON pursuant to any warranty OBTAINING WARRANTY SERVICE Customer must contact N TRON within the applicable warranty period to obtain warranty service authorization Dated proof of purchase from N TRON or its authorized reseller may be required Products returned to N TRON must be pre authorized by N TRON with a Return Material Authorization RMA number marked on the outside of the package and sent prepaid and packaged appropriately for safe shipment Responsibility for loss or damage does not transfer to N TRON until the returned
17. s not shown for clarity purposes In the event all Cat5e patch cable distances are small i e All Ethernet devices are located the same local cabinet and or referenced to the same earth ground it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals Revised 9 23 2009 11 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications 0 232 0 005 5 8940 1 27 CAT5e CABLE EIA 568B 0 237 0 005 6 02 0 1 3 CATSe CABLE Revised 9 23 2009 CONNECTING THE UNIT For the 100BaseFX Fiber Optic port remove the dust cap s from the fiber optic connector and connect the fiber optic cables The TX port on the local unit should be connected to the RX port of the far end device and the RX port should be connected to the TX port of the far end device For 10Base T ports plug a Category 3 or greater twisted pair cable into the RJ45 connector For 100Base T ports plug a Category 5 or greater twisted pair cable into the RJ45 connector Connect the other end to the far end station Verify that the LNK LED s are ON once the connection has been completed To connect any other port to another Switch or Repeater use a standard Cat5 straight through or crossover cable Warning Creating a port to port connection on the same switch i e loop is an illegal operation and will create a broadcast
18. s utilize the IEEE compliant SC or ST duplex connectors for fiber optic communications All 10 100Base TX ports utilize the RJ45 shielded connectors The 102MC MCE is a two port unmanaged media converter that converts 10 100BaseTX copper to 100BaseFX full duplex fiber The 104TX 105TX and 108TX are affordable and share a small footprint Each switch is capable of auto negotiating 10 100 Mb and half full duplex communications The 105FX FXE has 4 ports similar to the 104TX plus additional multimode fiber optic up link port s capable of 2 Kilometers of 100 Mb communications for the FX models and up to 80 Kilometers for the FXE models without the use of repeaters The 106FX2 FXE2 has 4 10 100BaseTX RJ 45 auto sensing ports and 2 100BaseFX ports with ST or SC connectors capable of 2 Kilometers of 100 Mb communications for the FX models and up to 80 Kilometers for the FXE models without the use of repeaters Key Features Full IEEE 802 3 amp 100Base FX Compliance Extended Environmental Specifications Support for Full Half Duplex Operation LED Link Activity Status Indication Autonegotiation Autosensing Speed Duplex and Flow Control Up to 1 6 Gb s Maximum Throughput Industry Standard 35mm DIN Rail Mounted Enclosure AEN Gore ce amp Qi RSEN 108TX HV Only Revised 9 23 2009 6 PACKAGE CONTENTS Please make sure the package contains the following items 1 100 Series Media Converter or Ethernet Switch 2
19. storm which will crash the network TROUBLESHOOTING 1 Make sure the O Power LED is ON 2 Make sure you are supplying sufficient current for the version chosen Note The Inrush current will exceed the steady state current by 2X 3 Verify that Link LED s are ON for both ports 4 Verify cabling used between stations 5 Verify that cabling is Category 3 or greater for 10Mbit Operation SUPPORT Contact N Tron Corporation at TEL 251 342 2164 FAX 251 342 6353 www n tron com N TRON_Support n tron com Revised 9 23 2009 13 FCC STATEMENT This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expens
20. the event the provided grounding screw has been lost care should be taken to limit the penetration of the outer skin by less than 1 4 Failure to do so may cause irreversible damage to the internal components of the switch Note Ensure the power supply is grounded properly before applying power to the grounded switch This may be verified by using a voltmeter to determine that DRAIN WIRE WITH LUGS 4 there is no voltage difference between the power supply s negative output terminal Ol A SR CAGE point and the chassis grounding point of the switch NONMETALLIC DIN RAIL MOUNT As an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecting a drain wire to earth ground from one of the V terminal plugs as shown here will ground the switch and the chassis The power leads from the power source should be limited to 3 meters or less in length DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GROUNDING POINT If the use of shielded cables is required it is generally recommended to only connect the shield at one end to prevent ground loops and interfere with low level signals i e thermocouples RTD etc Cat5e cables manufactured to EIA 568A or 568B specifications are required for use with N Tron Switches METALLIC NONMETALLIC SHIELDED PATCH CABLE STP STP Note Strain relief boot

Download Pdf Manuals

image

Related Search

Manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manually update your device drivers windows manual arts high school manual for courts martial manual definition manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manualidades manual transfer switch manual therapy cpt code manual blood pressure cuff manual transmission cars for sale manual handling manual digital manual autopilot enrollment