Home
F2X03 Series User Manual - Four
Contents
1. 11 138 151 161 When the DSC Internet access uses domain name It s necessary to set DNS server resolving the DSC domain name When the Data Center Number is 1 Main and Backup Center DNS Server is used to resolve the Main center and Backup center correspondingly AT command of Main Center DNS server AT DNSS VR aaa bbb ccc ddd aaa bbb ccc ddd The DNS server IP address must be IP address AT command of Backup Center DNS server AT DNSS V2 aaa bbb ccc ddd aaa bbb ccc ddd the DNS server IP address Center 2 5 DNS Server nd Center DNS Server 202 101 103 55 3rd Center INS Server 202 101 103 55 4th Center INS Server 202 101 103 55 oth Center INS Server 202 101 103 55 When the IP MODEM work in Multi Data Service Center method and the centers use domain name 2 5 DNS server is used to resolve center 2 5 correspondingly AT command of 2 5 DNS Server AT DNSS VRn aaa bbb ccc ddd nis 1 4 correspond to center 2 5 DNS server aaa bbb ccc ddd is the DNS server IP address 3 5 2 IP MODEM Settings IPMODEM WorkMode Xiamen Four Faith Communication Technology Co Ltd Page 17 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 PA Four Faith User Manual Hor kiloade FROT Y According to different application requirements there are several protocol workmode to choose PROT Heartbeat packe
2. 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual MODEM will keeps in idle state until it receives the trigger phone call then it will connect to the center AT Command AT CTRLNO xxx XXX trigger phone number SMS Trigger Password SMS Trigger Fassword 4 Bytes This item is valid only when the Trigger Type is SMSD or MIXD IP MODEM will keeps in idle state until it receives the trigger short message Then it will connect to the center AT Command AT SMSDPSW D xxx xxx SMS content to trigger IP MODEM online Data Trigger Password ata Trigger Un Password don ata Trigger Off Password daft This item is valid only when the Trigger Type is DATA or MIXD IP MODEM will keeps in idle state until it receives the trigger on data then it will connect to the center It will return to the idle state when receives trigger off data AT Command of Data Trigger On Password AT DONPSWD xxx Xxx data trigger on password AT Command of data trigger off password AT DOFFPS W D xxx Xxx data trigger off password TCP MTU TCF MTU Bytes 1450 Xiamen Four Faith Communication Technology Co Ltd Page 25 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User M
3. From DTU LJ Conti zg Save Contig The Serial Parameters column shows the current serial port settings To configure IP MODEM please choose the correct serial port which connects to IP MODEM and the baudrate is 115200 with no parity then open the serial port If the button text is Close it shows the serial port now has been opened If the text is Open you should open the port first When the port opened the Output Info column will display Port COM1 Has Opened Please Re Power the IP MODEM Waiting IP MODEM Enter Configure State 3 4 Re power IP MODEM Four Faith DIU Config Tool 1 1 0 Work State Switch Serial Parameters Config Communication Reboot Device Enter Communication State COM com x Baudrate 115200 x Parity Fone z Close Output Info DTU Config Should Return To Main Server 0 Data Service Center Settings pry Settings Other Settings Dns Server s Ip 202 101 103 55 Data Center Humber fi 7 Second Dns Server s Ip aliloale se llspboa leat Dns Serverl s Ip 202 101 103 55 Data Center Address and Port Dns Server s Ip 202 101 103 55 Dns Server3 s Ip 202 101 103 55 Main Center Addr Port 166 111 8 238 23 Dns Server4 s Ip 202 101 103 55 Sms Center 8613800592500 Backup Center Addr Port bbs nju edu cn 23 i 3000 Control Phone No a 2nd Center AddrtPo
4. item is set to 1 all the transmission is transparent AT Command AI STRAIGHT x x Oorl 3 5 3 Other Settings Network APH cmnet Username oo Password a 0 Call Center O gge Note APN access point name Username username to login the ISP network Password password to login the ISP network Call Center the call center phone number AT Command of APN AT APN xxxx XXXX access point name Xiamen Four Faith Communication Technology Co Ltd Page 23 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual AT Command of Username AT USERNAME xxx XXX username AT Command of Password AT PASSWORD xxx XXX password AT Command of Call Center AT CENT xxx xxx call center phone number of ISP SMS Center SMS Center 86 3 56 13800592500 Your local SMS center number AT Command AT SMSC xxx xxx your local SMS center number Heartbeat Interval Heartbeat Interval 31 65534 60 Time interval sent heartbeat packet unit is second AT Command AT POLLTIME xxx Xxx heartbeat packet time interval Call Trigger Phone No Call Trigger Phone Ha This item is only valid when the Trigger Type is CTRL or MIXD In this trigger type IP Xiamen Four Faith Communication Technology Co Ltd Page 24 of 30 Add J1 J3 3 Floor No
5. parity 1 Stopbit 8O01 8 Databit Odd parity 1 Stopbit AT Command AT SERMODE xxx xxx one of the above serial mode Communication Baudrate Xiamen Four Faith Communication Technology Co Ltd Page 19 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual Communication Baudrate 115200 110 110 bps 300 300 bps 600 600 bps 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 bps 14400 14400 bps 19200 19200 bps 38400 38400 bps 56000 56000 bps 57600 57600 bps 115200 115200 bps AT Command AT IPR xxx Xxx one of the above baudrate Auto Back To Main Server Auta Back To Main Server lo 1 0 Yes Ho 0 No 1 Yes This item is only valid when you set Data Center Number as 1 In this mode IP MODEM will switch to backup center when main center have problems If this item is set to 1 IP MODEM will check whether the main center work fine timely When it detects the main server work fine it will return back to the main server at once AT Command AT RETMAIN x x Oorl Device ID Device ID amp Bytes TAT ABST Hex Decimal Characters Xiamen Four Faith Communication Technology Co Ltd Page 20 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith
6. state you can configure the parameters through AT command Xiamen Four Faith Communication Technology Co Ltd Page 30 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735
7. your existing serial devices with only basic configuration It has been widely used on M2M fields such as intelligent transportation smart grid industrial automation telemetry finance POS water supply environment protection post weather and so on at 2 5G 3G Internet a Network IP Modem Data Center Acquisition module 1 2 Features and Benefits Design for Industrial Application High powered industrial cellular module High powered industrial 16 32 bits CPU Support low consumption mode including sleep mode scheduled online offline mode scheduled power on power off mode optional Housing iron providing IP30 protection Power range DC 5 35V Stability and Reliability Support hardware and software WDT Support auto recovery mechanism including online detect auto redial when offline to make it always online RS232 RS485 RS422 port ISK V ESD protection SIM UIM port 15KV ESD protection Power port reverse voltage and overvoltage protection Antenna port lightning protection optional Standard and Convenience Xiamen Four Faith Communication Technology Co Ltd Page 6 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Pt Four Faith User Manual Support standard RS232 and RS485 or RS422 port that can connect to serial devices directly Support intelle
8. F2X03 Series Documentation No Product Version F2X03 Series User Manual The user manual is suitable for the following model Product Type GSM IP MODEM GPRS IP MODE CDMA IP MODE F2303 EDGE IP MODE F2403 WCDMA IP MODEM F2503 TD SCDMA IP MODEM F2603 EVDO IP MODEM Xiamen Four Faith Communication Technology Co Ltd Add J1 J3 3rd Floor No 44 GuanRi Road SoftWare Park XiaMen China Zip Code 361008 Tel 86 592 6300326 6300325 6300324 Four Faith Fax 86 592 5912735 http www fourfaith com Pt Four Faith User Manual Files Revised Record Xiamen Four Faith Communication Technology Co Ltd Page 2 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual Copyright Notice All contents in the files are protected by copyright law and all copyrights are reserved by Xiamen Four Faith Communication Technology Co Ltd Without written permission all commercial use of the files from Four Faith are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Four Faith VU uct an rote ran US S are all registered trademarks of Xiamen Four Faith Communication Technology C
9. anual The maximum transmission unit of TCP packet AT Command AT TCPMTU xxx xxx the MTU value Multi Center Reconnect Interval Multi Center Reconnect Interval qc This item is valid only when the Data Center Number is greater than 1 When one of the configured data center lost connection IP MODEM will try to reconnect after the configured reconnect interval AT Command AT MCONTIME xxx XXX reconnect time interval unit is second 3 6 Functions Clear Output Clear Output E Clear the output information Version Display Ver Info Show the software and hardware version Signal Value Signal Yalue T Display current wireless signal value Factory setting Factory Setting Restore to factory settings Show Config Show Config Xiamen Four Faith Communication Technology Co Ltd Page 26 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Rp Four Faith Show current IP MODEM settings Show Baudrate Show Baudrate Display the communication baudrate Auto Detect Auto Detect A Simple way to determine whether IP MODEM work fine User Manual Save Output Save Output Save the output info to a file Save Config Save Contig Save the current settings to a file you can restore it from this file later Restore Config Brow
10. arciaivnatwuaeisatesaeiestosancbsloveenleddiesessabananuadbenznnds 12 Chapero Connon LOIN ic cdetea ce tc ccreiiae E eccnevntdsa EE EEE E tach ionb aia 13 ijl COMME AON ONE CHOI srren Erao eo n Oaea e Eoen a OSET 13 32 opi CUP AON miroduc Oi c1sarcacreccesssseananancsgsecsanespeasasacnensaneteonsnsedheoscnacuensseasneusenetacenaness 13 3 3 Run the configure Tool IP Modem Configure exe neeessssssssssssssseeereressssssssssssssseeeereee 14 S34 Re powert IPFMODEM esince i EEEN 14 I O a E E toyed tovanseaeapaeecarones 15 IA Data service C enler 5 CU On eiers a eanne ERRER ETSER ERASERS E 15 eZ IP MODEM SNES pee EE EREE EE E 17 i Ne MOC ES HS E A E A AE SA A A N E A E N E E 23 IO PUCO sipe a E E AEE ESETE EN EER 26 S VO O E S a A E E T A E TE T 27 PRU E E E E 28 Xiamen Four Faith Communication Technology Co Ltd Page 5 of 30 Add http J1 J3 3 Floor No 44 Guan RiRoad SoftWare Park XiaMen 361008 China www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Rp Four Faith User Manual Chapter 1 Brief Introduction of Product 1 1 General F2X03 series IP MODEM is a kind of cellular terminal device that provides data transfer function by public cellular network It adopts high powered industrial 16 32 bits CPU and embedded real time operating system It supports RS232 and RS485 or RS422 port that can conveniently and transparently connect one device to a cellular network allowing you to connect to
11. com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual The identity number of IP MODEM the value should be 8 bytes hex decimal characters AT Command AT IDNT aabbccdd aabbccdd the identity number of IP MODEM SIM Card No SIM Card Hof 11 Bytes 13912345678 The phone number of the SIM card AT Command AT PHON XXXXXXXXXX XXXXXXXXXXX the SIM card phone number Bytes Interval Bytes Interval Mefault 20 ms The time interval used to determine whether the serial data frame transmission has completed IP MODEM will send the serial data to the center when two bytes transmit time interval larger than this item value AT Command AT BYTEINT xxx xxx bytes interval time value millisecond Custom Register String Custom Register String This item is only valid when the WorkMode is TCST It s the self defined register string It can be empty the maximum length is 70 bytes AT Command Xiamen Four Faith Communication Technology Co Ltd Page 21 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Pt Four Faith AIT CONNRGST xxx xxx self defined register string User Manual Custom Heartbeat String Custom Heartbeat String This item is only valid when the WorkMode is TCST It s the self defined heartbeat string It can be empty the maxim
12. ctual mode enter into communication state automatically when powered Provide management software for remote management Support several work modes 0 Convenient configuration and maintenance interface High performance Support TCP server and support multi TCP client connection optional Support double data centers one main and another backup Support multi data centers and it can support 5 data centers at the same time Support multi online trigger ways including SMS ring and data Support link disconnection when timeout Support dynamic domain name DDNS and IP access to data center Design with standard TCP IP protocol stack Support APN VPDN 1 3 Working Principle The principle chart of the IP MODEM is as following Cellular Module Embedded processing DATA Interface system Power RS232 serial RS485 serial Indicator lights Interface Interface 1 4 Specifications Cellular Specification Standard and Band Bandwidth TX power RX sensitivity F2103 GPRS IP MODEM EGSM900 GSM1800MHz 85 6Kbps GSM850 900 lt 107 GSM850 900 1800 1900MH_z optional lt 33dBm dBm Compliant to GSM phase 2 2 GPRS class 10 class 12 optional GSM1800 1900 Xiamen Four Faith Communication Technology Co Ltd _ Page 7 of 30 Add J1 J3 Se eae oO Giana No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Pt Four Faith Use
13. ion Technology Co Ltd Page 28 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Rp Four Faith User Manual 4 Configure the serial port parameters as following choose OK Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None COM1 Properties Port Settings Bits per second 175200 Data bits 9 Parity None Stop bits Flow control fen Restore Defaults 5 Complete Hyper Terminal operation It runs as following ff HyperTerminal File Edit Yiew Call Transfer Help Connected 0 00 06 Auto detect Auto detect Xiamen Four Faith Communication Technology Co Ltd Page 29 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Rp Four Faith User Manual 6699 S 6 Re power IP MODEM put mouse focus on the Hyper Terminal and press key continuously until IP MODEM enter configure state as following ff HyperTerminal File Edit View Call Transfer Help System started Press s key continuously to enter configure program Four Faith DTU CONFIGURE PROGRAH Use the extended AT commands to configure the DTU Input AT LIST lt cr gt For help Connected 0 00 46 Auto detect 115200 8 N 1 7 IP MODEM has entered configure
14. ith User Manual 8 nad 22 c 4 28 E 3 oy 35 25 28 ja 08 5 l Installation of SIM UIM card Firstly power off the IP MODEM and press the out button of the SIM UIM card outlet with a needle object Then the SIM UIM card sheath will flick out at once Put SIM UIM card into the card sheath Pay attention to put the side which has metal point outside and insert card sheath back to the SIM UIM card outlet Warning Forbid to install SIM UIM card when powered Installation of antenna Screw the SMA male pin of the antenna to the female SMA outlet of the IP MODEM tightly Warning The antenna must be screwed tightly or the signal quality of antenna will be influenced Installation of cable Insert DB9F end of the RS232 RS485 data cable into the DB9M interface of IP MODEM and connect the other end with user s device The signal connection of the RS232 data cable is as follows DB9F DB9F RS232 data cable Xiamen Four Faith Communication Technology Co Ltd Page 11 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Pt Four Faith User Manual The signal connection of the RS485 data cable is as follows DB9F l 2 3 4 5 6 A RED 7 8 B 9 B BLACK RS485 data cable 2 4 Power The power range of the IP MODEM is DC 5 35V Warning When we use other power we should make sure that
15. llowing describes how to configure IP MODEM with the configure software tool At the same time it gives out the corresponding AT command of each configuration item Xiamen Four Faith Communication Technology Co Ltd Page 13 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Rp Four Faith User Manual 3 3 Run the configure Tool IP Modem Configure exe P Four Faith DIV Config Tool 1 1 0 lol x Work State Switch Serial Parameters te Config Communication Reboot Device Enter Communication State COM com 7 Baudrate 115200 x Parity Hone 7 Close Output Info DTU Config gt gt gt Port COM1 Has Openeds Please Re Power the DTU Data Service Center Settings oru Settings Other Settings Waitting DTU Enter Configure State Data Center Number Data Center Address and Port Main Center AddrtPort Backup Center AddrtPort is ns 2nd Center AddrtPort 4 E 3rd Center AddrtPort 4th Center AddrtPort SthCenter AddrtPort DINS Server Main Center DNS Server Backup Center DNS Server e 2nd Center DNS Server o Srd Center DNS Server ne z 4th Center DNS Server D Sth Center DNS Server Functions buto Detect A etting Clear Output Save Output W Restore oad
16. nna Standard SMA female interface 50 ohm lighting protection optional SIM UIM Standard 3V 1 8V user card interface 15K V ESD protection Power Standard 3 PIN power jack reverse voltage and overvoltage protection 9 A m E 0 Standard SMA female interface 50 ohm 2 Standard 3 PIN power jack RS232 RS485 serial port Power Input Item Content Physical Characteristics Environmental Limits Operating 25 65 C 13 149 F Temperature Extended 30 4 75 C 22 167 F Operating Temperature Storage 40 85 C 40 185 F Temperature Operating 95 Non condensing Xiamen Four Faith Communication Technology Co Ltd Page 9 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Pt Four Faith User Manual Chapter 2 Installation Introduction 2 1 General The IP MODEM must be installed correctly to make it work properly Warning Forbid to install the IP MODEM when powered 2 2 Encasement List TPMODEMHos o fantema E Powerage J oo Mawae o o emama o Mainen OOO 2 3 Installation and Cable Connection Dimension unit mm Xiamen Four Faith Communication Technology Co Ltd Page 10 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 PA Four Fa
17. o Ltd illegal use of the name of Four Faith trademarks and other marks of Four Faith is forbidden unless written permission is authorized in advance Xiamen Four Faith Communication Technology Co Ltd Page 3 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual Teg Dey ning y ASV eta 35 VDC otage Xiamen Four Faith Communication Technology Co Ltd Page 4 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual Contents Chapter I Brier Introduction of Product isccesacssacssncnsocucsdasodasunsuatoaanousvoudesastonsnsceneuameeasousbacguaatoneatenses 6 BE E A E E T RE 6 12 Pears and Benes oas e a iaoiaeii 6 CoN P 1 E a E ATEA 7 LA SOS OS a E N E O 7 Chapter 2 Installation Introd ction 22222s0s0s01s0ceesacncqtecedensnnasnenseaesneccanessaasbeassonsnnasnoacbeetnencasesueasoeass 10 2 NA TMG Mall cee case serra sna wcseesa nase A magtonan Satseseioal aucpdaliay aera baeosaad sebmelod a 10 DD TMC ABCC LAS A E E A sd E A A E T EN E E E N 10 2 3 Installation and Cable Connection 3 sssscscssscnaacessannecacdendewsasvanersairesuansiausvonswoasuaviaaneusaiensasnexsass 10 DON OW A E E E A O 12 29 Indicator Liohts Introduction c usierk oxsievtcausiaas c
18. r Manual cn F2203 CDMA IP MODEM CDMA2000 1xRTT 800MHz 153 6Kbps lt 30dBm lt 104 800 1900MHz optional dBm 450MHz optional F2303 EDGE IP MODEM GSM850 900 1800 1900MHz 236 8Kbps GSM850 900 GPRS EDGE Class 12 lt 33dBm GSM1800 1900 lt 30dBm F2403 WCDMA amp HSDPA amp HSUPA IP MODEM UMTS WCDMA HSDPA HSUPA HSUPA 5 76Mbps lt 24dBm 850 1900 2 1OOMHz Upload speed 850 900 1900 2 1 00MHz optional GSM850 900 1800 1900MHz HSDPA 7 2Mbps GPRS EDGE CLASS 12 Download speed UMTS 384Kbps DL UL F2503 TD SCDM IP MODEM TD SCDMA HSDPA HSUPA Download speed 2 8Mbps lt 24dBm 1880 1920 2010 2025MHz Upload speed 2 2Mbps GSM850 900 1800 1900MHz GPRS EDGE CLASS 12 F2603 CDMA2000 1X EVDO IP MODEM CDMA2000 1X EVDO Rev A Download speed 3 1Mbps lt 23dBm 800MHz 800 1900MHz optional Upload speed 1 8Mbps 450MHz optional CDMA2000 1X RTT IS 95 A B Hardware System Content Industrial 16 32 bits CPU 1MB Extendable 512KB Extendable Interface Type Serial 1 RS232 port and 1 RS485 orRS422 port 15K V ESD protection Data bits 5 6 7 8 Stop bits 1 1 5 2 Xiamen Four Faith Communication Technology Co Ltd Page 8 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 g Four Faith User Manual Parity none even odd space mark Baud rate 110 230400 bps Indicator Power ACT Online Ante
19. rt 166 111 8 238 23 Custom Register Info i 3rd Center AddrtPort 166 111 8 238 23 Custom Keep Online Info A Bytes Finish Interval ms 20 4th Center Addr Port 166 111 8 238 23 Data Daemon PPP On Password don Data Daemon PPP Off Password doff F 166 111 8 238 Link Fail Betty Times j 65535 Sth Center Addr Port 166 111 8 238 23 Max Tep Frame Len 1450 90 DNS Server IPR 115200 Main Center DNS Server 202 101 103 55 E Backup Center DNS Server 211 138 151 161 2nd Center DNS Server 202 101 103 55 paT Aata 3rd Center DNS Server 202 101 103 55 4th Center DNS Server 202 101 103 55 Sth Center DNS Server 202 101 103 55 le Functions Show Config Show Baudrate Auto Detect A Ver Info Signal Value I Clear Output Save Output amal Value Save S Load From DTU L Browse Restore Config Save Config After Re power IP MODEM The configure tool will make it enter configure state At the Xiamen Four Faith Communication Technology Co Ltd Page 14 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual same time the software will load current settings from IP MODEM and displays on the right configure columns It s now ready to configure 3 5 Configura
20. rt AT PORT xxx xxx The port value Backup Center Addr Port IP address and port of the Backup DSC Backup Center Addr P ort bbs nju edu cn oo AT command of the Backup DSC IP address or domain AT IPSEC xxx xxx The IP address or domain name AT command of the Backup DSC port AT PTSEC xxx xxx The port value Multi DSC Configuration end Center AddrtPort 168 111 8 238 poao rd Center AddrtFort 166 111 8 238 pao 4th Center AddrtPort testi 2o Sth Center AddrtPort 168111823 23 When Data Center Number is greater than 1 this setting is valid For example setting the Data Center Number as 3 Main Center 2nd Center 3rd Center work as these three DSC AT Command of the 2 5 DSC IP address or domain name AT IPADn xxx nis 1 4 correspond to center 2 5 xxx The IP address or domain name AT Command of the 2 5 DSC port AT PORTn xxx nis 1 4 correspond to port of center 2 5 xxx The port value Example Set IP address of center 3 as 166 111 8 238 and port 5001 the AT command is as following AT IPAD2 166 111 8 238 Xiamen Four Faith Communication Technology Co Ltd Page 16 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual AT PORT2 5001 Main and Backup Center DNS Server Main Center INS Server 0z 101 103 55 Backup Center INS Server
21. se Restore Config Restore settings from a previous saved configure file 3 7 Work State Switch fork State Switch f Config Communication Reboot Device Enter Communication State This tool can work in two states Config and Communication Config This state is used to configure parameters of IP MODEM Communication This state is used as a common serial communication tool Reboot Device Enter Communication State This function button is used to reboot IP MODEM and make the software switch to Communication state Xiamen Four Faith Communication Technology Co Ltd Page 27 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Rp Four Faith User Manual Appendix The following steps describe how to make IP MODEM enter configure state with the Windows XP Hyper Terminal 1 Press Start gt Programs gt Accessories gt Communications gt Hyper Terminal Connection Description Eg New Connection Enter a name and choose an icon for the connection Name fe loon 2 Input connection name choose OK 3 Choose the correct COM port which connect to IP MODEM choose OK Connect To Enter details for the phone number that you want to dial Country region Area code EZ Connect using Wagi DK i Cancel Xiamen Four Faith Communicat
22. t with TCP protocol Data transmission with TCP protocol heartbeat packet and application data transmission are in the same TCP connection TRNS IP MODEM work as a common GPRS MODEM It can be used in SMS CSD dial up applications TTRN Heartbeat packet with UDP protocol Data transmission with TCP protocol TLNT IP MODEM work as a telnet client LONG Heartbeat packet with UDP protocol Data transmission with TCP protocol It can transmit at most 8192 bytes data one time through extra application protocol LNGT Heartbeat with TCP protocol Data transmission with TCP protocol It can transmit at most 8192 bytes data one time through extra application protocol TUDP Heartbeat with UDP protocol Data transmission with UDP protocol Heartbeat packet and application data are in the same UDP connection TCST User can set custom register and heartbeat string Data transmission with TCP protocol SUDP User can set custom register and heartbeat string Data transmission with UDP protocol PUDP No register packet and heartbeat packet Data transmission with UDP protocol TCPSVR TCP server support 4 client simultaneously Need a static IP address from carrier AT command AT MODE xxxx XxXxx one of the above workmode Trigger Type Trigger Type Default Auto AUTO Normally IP MODEM always keeps online and always be ready for data transmission But in some circumstances it s important to reduce wireless data flow To realize this f
23. the power can supply power above 4W We recommend user to use the standard DC 12V 0 5A power adaptor 2 5 Indicator Lights Introduction The IP MODEM provides three indicator lights Power ACT Online Indicator State Introduction Light Power IP MODEM is powered on OFF IP MODEM is powered off OFF No data Online IP MODEM has logged on network OFF IP MODEM hasn t logged on network Xiamen Four Faith Communication Technology Co Ltd Page 12 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual Chapter 3 Configuration 3 1 Configuration Connection Before configuration it s necessary to connect the IP MODEM with the configure PC by the shipped RS232 or RS232 485 conversion cable as following RS232 cable or RS232 485 convertor cabl P 3 2 Configuration Introduction There are two ways to configure the IP MODEM Configuration software tool All the settings are configured through the shipped software tool It s necessary to have one PC to run this tool Extended AT command All the settings are configured through AT command so any device with serial port can configure it Before configuration with extended AT command you should make IP MODEM enter configure state The steps how to make IP MODEM enter configure state please refer to appendix The fo
24. tion 3 5 1 Data Service Center Settings Settings on this page are the parameters related to Data Service Center DSC Data Center Number IP MODEM support two Data Service Center methods to transmit data Main and Backup IP MODEM always tries to connect with the Main DSC If fails to connect with Main DSC it will connect with Backup DSC at once Note If no Backup DSC exists please configure the Backup DSC same as Main DSC Multi Data Service Center IP MODEM can connect with at most five DSC at the same time All the multi DSC can receive the same application data Data Center Number fi If the Data Center Number is 1 IP MODEM work in Main and Backup DSC method When Data Center Number is greater than 1 IP MODEM works in Multi Data Service Center method AT command AT S VRCNT x x Data Service Center number Note every AT command is terminated with a enter character Main Center Addr Port IP Address and Port of the Main DSC It s better to set the port greater than 1024 Main Center AddrtFort 166 111 8 238 oo AT command of the Main DSC IP address or domain name AT IPAD xxx Xiamen Four Faith Communication Technology Co Ltd Page 15 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual xxx The IP address or domain name AT command of the Main DSC po
25. um length is 70 bytes AT Command AT LINKRGST xxx xxx self defined heartbeat string Connect Retry Times Reconnect Time Interval Connect Retry Times B5539 Reconnect Time Interval Seconds T In normal applications IP MODEM will always try to connect with the center even if the center has problems or closed To reduce these unnecessary wireless data flow you can configure the Connect Retry Times and Reconnect Time Interval items When IP MODEM fail to connect to the center with the configured Retry Time It will sleep Reconnect Time Interval time then start next retry Connect Retry Times AT Command AT RETRY xxx XXX times try to connect to the center Reconnect Time Interval AT Command AT RDLW T xxx xxx the sleep time until next retry Transfer meanning Transfer Meaning 0 1 Yes Ho jo Xiamen Four Faith Communication Technology Co Ltd Page 22 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 RF Four Faith User Manual 0 Yes enable transfer meaning 1 No disable transfer meaning This item is only valid when the WorkMode is PROT If this item is set to 0 IP MODEM will transfer meaning to Oxfd and Oxfe To know detail transfer meaning method please refer lt lt IP MODEM Transfer Meaning Explanation In the PROT work mode gt gt If this
26. unction the software can makes IP MODEM into sleep state in idle time When there is application data to transmit IP MODEM can be triggered online ready for data transmission There are total five methods to make IP MODEM online AUTO IP MODEM always keeps online SMSD send a special short message to make IP MODEM online CTRL make IP MODEM online through a phone call to IPMODEM DATA send special serial data to make IP MODEM online Xiamen Four Faith Communication Technology Co Ltd Page 18 of 30 Add J1 J3 3 Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Pt Four Faith User Manual MIXD the combination of SMSD CTRL DATA IP MODEM will be online when meet one of these three trigger methods AT Command AT ACTI xxxx XXXX one of the above trigger methods Debug Level Debug Level CO1 2 9 fi Debug information is used to debug software when there is software problem 0 no debug information output 1 simple prompt information output 2 detail debug information output AT Command AT DEBUG x x the debug level value Note Only there is some problem to the IP MODEM It s necessary to set this value as 2 In normal applications this value should set to 0 or 1 the default value is 1 Databit Parity Stopbit atabit Parity Stopbit Hi F 8N1 8 Databit No parity 1 Stopbit SE1 8 Databit Even
Download Pdf Manuals
Related Search
Related Contents
Ecran HP ProDisplay P232 de 58,4 cm (23 pouces) NEWS-II Solarium Rayonnements et santé - UV-Index "取扱説明書" Première approche des fonctions de nutrition : la digestion Shimano M780 XT 3:2x10 Shift Lever Set I 2200, 2200H & 2200-GFI Mytee-Dry™, 2300 Whisper Manual Copyright © All rights reserved.
Failed to retrieve file