Home
EKZ006600F_Dom_User_EN:NOTICE 0066 00B.qxd
Contents
1. When arming total set confirms that the TOTAL SET TTI control panel has received a valid code or ARMING TAG and is preparing to arm total set Duration 4 seconds PARTIAL SET s f2 modulated d ARMING A A When arming the partial set confirms that LA Anh the control panel has received a valid code ANNEX SET Duration 2 5 d or TAG and is preparing to arm partial set ARMING uration 2 5 seconds Upon arming Total set arming beeps continue until final EXIT DELAY exit door is closed Partial set arming beeps continue for 30s one beep per second until partial set is armed After closing the final door ARMING Ol When closing the final exit door confirms COMPLETE that the system is armed Three fast beeps Upon eni This entry tone sounds for 30 seconds ENTRY after you open the entry door You should DELAY disarm your system within this time one beep per second Long and continuous beep DISARMING When Disarming confirms that the control panel has been successfully disarmed Duration 2 5 seconds 2 times 7 fast beeps FAULT F This signal indicates a fault in the system 4 beeps upon alert ALERT Confirms the transmission of an alert to the sent via the keypad alarm company Defined by user during installation How
2. gt At the end of the arming delay or D is displayed to confirm that the system is armed The arming light then goes out and the screen clears after a few seconds Note Depending on the configuration of your keypad you may be able to arm your system without the identification process ARMING OF THE ANNEX SET This can only be done from the TCU menu Press EVENTS TOOLS USERS TESTS PREFERENCES OORUN Select ANNEX SET from the menu using Confirm your choice with Enter your user code or present your TAG gt The arming process is signalled by a series of beeps and the screen counts down the exit time remaining ARMED IN 20 SECONDS If your system is set up to arm once the final door has been closed close this door to complete the arming process Otherwise you must leave the premises before the end of the exit delay gt The Ld icon confirms arming of the Annex set The screen clears after a few seconds NB Depending on the configuration of your system you may not have an Annex In this case the message INACTIVE FUNCTION will be displayed on the TCU screen DISARMING USING YOUR CODE OR TAG Note that the disarming process may vary depending on your system configuration Your installer may set an entry delay of several seconds Enter your 4 to 6 digit user code or present your TAG gt The disarming tone is emitted by the keypad and by the panel s
3. Please contact your alarm company if this indication persists Flashing slowly A system fault is in memory on set indicated on LED 2 and requires a reset Off No system fault 4 LED INDICATOR TAMPER ALARM uu ccccccscscssscsssscsssscsssccssecsssecsssssssccessesessscsssscnsssesssceessvesssensevens On A tamper alarm is occurring on set indicated on LED 2 Flashing slowly A tamper alarm is in memory on set indicated on LED 2 and requires a reset Off No tamper alarm S LED INDICATOR INTRUDER ALARM maia On An intruder alarm is occurring or a detector is triggered on set indicated on LED 2 This includes open door contact movement detection or smoke detection Flashing slowly An intruder alarm is in memory on set indicated on LED 2 and requires a reset Flashing quickly A confirmed alarm is in memory and requires a remote reset Please call your monitoring operation at the alarm company Off No intruder alarm Understanding the system tones SIRENS A siren is an effective deterrent due to its power and very irrating tone The system has a siren built into the control panel and an optional outdoor and or indoor wireless siren can be added The panel siren emits an audible confirmation tone when arming and disarming the security system and a fire tone when a smoke detector is triggered Volume levels can be adjusted by the installer SYSTEM TONES Sequence of 3 modulated sounds
4. comes on briefly when you release the button gt The disarming tone is emitted by the panel siren l PERSONAL ATTACK This function is optional and can be set up at installation These keys enable you to send an alarm at any time c gt Press and gt The indicator light on the keyfob comes on briefly when you release the button gt The siren is triggered gt The alarm company is alerted The panic function can be used even when your system is not armed If this has been set up by the installer the siren stops automatically after 30 seconds but you can stop it manually by pressing the disarm button o Stopping the siren does not interrupt the transmission to the alarm company SPECIAL KEY The action of the key is dependent on your configuration As an assistance button it enables you to call for assistance from your alarm company Press the key pause until the indicator light comes on then press again As a remote control for electrical appliances press the key to turn each appliance on and off successively This function requires an optional X10 extension with X10 receivers Depending on your needs your installer will advise you on the different options for controlling appliances How to use the keyfob with 3 LEDs The keyfob can be used to arm or disarm your security system to trigger an audible or silent alert as well as to control electrical
5. master Select and enter a single digit user ID 0 to 9 Enter the new code for this user gt A double beep on the keypad will confirm acceptance of the new code Re enter the new code to confirm gt A double beep on the keypad will confirm acceptance of the new code Exit programming mode by pressing CHANGING OR SETTING ADDITIONAL KEY TAGS A key TAG can only be programmed for a user who already has a code To change or set additional key TAGs you need to enter programming mode Press and simultaneously gt The red light will flash slowly Enter the master code or present the master TAG user 1 Enter an existing single digit user ID 0 to 9 Present the new key TAG A double beep on the keypad will confirm that the new TAG is programmed and replace the previous TAG if any gt Exit programming mode by pressing ADJUSTING THE BEEP LEVEL The level of system tones emitted by the panel siren can be adjusted using the keypad To change the beep level of the panel siren you need to enter programming mode c Press and simultaneously lt gt The red light flashes slowly Press followed by Enter a new level from 1 to 7 gt A double beep on the keypad will confirm that the level has been changed Exit programming mode by pressing 1990000 20008 4 00000 ei How to use the keyfob with 1 LED The keyfob can be used to arm
6. move up and down Confirm your choice with as in the first screen below BYPASS DETECTORS BYPASS DETECTORS ROOM 1 lt ACTIVE gt lt INACTIVE gt NO YES Select Active or Inactive using GS then confirm your choice with A keypad beep confirms your choice Press to return to the Tools menu Bypassed detectors are displayed with their names struck through The icon it blinks to tell you that one or more detectors are bypassed CANCELLING OPERATOR ACCESS This function allows the master user to disable the operator s maintenance access to the system Select 4 OPERATOR ACCESS in the TOOLS menu Enter the User Code or present a User TAG The screen displays TOOLS OPERATOR ACCESS 1 REMOTE PLUGS 2 SEARCH TCU ACCESS TO MY 3 BYPASS DETECTOR SYSTEM 4 OPERATOR ACCESS lt ALLOWED gt lt NOT ALLOWED gt NO YES Select Allowed or Not Allowed using D Gs then confirm your choice with A keypad beep confirms your settings cm Press to return to the Tools menu THE PREFERENCES MENU SETTING SILENT MODE The panel siren s arming and disarming beeps can be modified by activating or deactivating Silent Mode Note You cannot deactivate the fire or intruder siren gt Active No beeps on the panel gt Inactive Beeps on the panel are active gt Partial Set only Beeps are not active when the Partial Set is armed This does not affect the keypad
7. or disarm your security system to trigger an audible or silent alert as well as to control electrical appliances from a distance see Special Key on page 29 This keyfob is optional but 1 to 10 keyfobs of this type may be included with this system ARMING OF THE TOTAL OR PARTIAL SET To arm the Total or Partial set press the Total or Partial arm button gt The indicator light on the keyfob comes on briefly when you release the button gt The arming tone is emitted by the panel siren gt The Total Set arming tone POMPA gt The Partial Set arming tone LMR Always make sure that your arming request is followed by the tone ARMING WITH FAULT If the system diagnoses a fault on arming you cannot set the alarm Faults include system faults tampering and triggering of detectors gt A tone indicating a fault is emitted by the panel siren after the arming request instead of the arming tone Check that all doors and windows equipped with detectors are closed lt gt You can override prevention of arming by requesting arming a second time within two minutes of the first request This will bypass all faults gt The arming process restarts the arming tone is emitted by the panel siren followed by the exit delay beeps Arming is completed at the end of the delay DISARMING To disarm press the disarm button a gt The indicator light
8. to use the wireless keypad with display INTRODUCTION TO THE TCU KEYPAD Screen TAG identification area Total set Partial set arming key arming key Total set Partial set arming light arming light Keytag TAG Validation amp for identification Disarming Go to Status key previous menu Cancel choice key Shortcuts and Shortcuts and menu browsing key menu browsing key Codes text entry keypad The wireless keypad with display offers a complete range of tools to manage your alarm system from normal operation to dedicated user functions This keypad is optional but 1 to 4 keypads of this type may be included with this system The keypad is used to arm and disarm your security system using a valid access code or key TAG The master code or TAG is required to modify other users codes and TAGs and to authorise the alarm company to access the system for maintenance Other user functions include remote control of electrical equipment manual bypass of detectors setup of beeps and equipment testing This keypad also provides full system status information with display icons messages and beeps emitted by the keypad You can also view the history of alarms that have occurred NB This keypad is suitable for indoor use only This function requires an optional X10 extension with X10 receivers THE TCU SCREEN AND ICONS Total set armed A Partial set disarmed System disarmed A A
9. you cannot allocate code 2346 to someone else but 2347 2348 etc To modify existing codes Select 1 CODES and press to see the list of users Enter the Master Code or present the Master TAG Select a user with Qp GD as shown in the first screen below Confirm your choice with or press to return to the menu A beep confirms your choice Select the user Enter the code Authorise the code lefe 0 5 1 USER 1 2 CHRISTOPHER CHRISTOPHER AUTHORISE CODE Press to confirm each screen or to cancel After the last screen a tone confirms your settings ADDING MODIFYING OR REMOVING TAGS This function allows you to allocate TAGs to different users Select 2 TAGS and press Enter the Master Code or present the Master TAG The list of users is displayed To assign a TAG to an existing user Select a user from the list with GSD and confirm your choice with The following screens are displayed Authorise the TAG Show the TAG Accept the TAG Frrememene ANIRIBUTE TAG TO VIRGINIA VIRGINIA WA ALOE SHOW YOUR TAG CANCEL NO 0 0 Press to validate each screen or to cancel the operation Touch the Tag to the Tag Identification Area within 10 seconds A tone confirms that the tag has been recognised and added to your security system gt When a new TAG is assigned to a user it overwrites the existing tag To disable a TAG Selec
10. 060 This keypad is used to arm and disarm your security system using a valid access code or key TAG O It is equipped with a proximity reader positioned in the TAG Identification Area e x A ARMING USING YOUR CODE OR TAG Press an arming key on the keypad and enter the code or present a programmed TAG O 4 or 6 Digit code gt __ Arms the total set 4 or 6 Digit code gt _ Arms the partial set 4 or 6 Digit code gt _ Arms the annex set A flashing red light on the keypad confirms that the code is valid The arming tone OMAA MA is emitted by the panel siren followed by the exit delay beeps gt Total set arming is completed after you close the final exit door After the door is closed the exit delay beeps stop and the arming complete tone is emitted by the panel siren gt Partial set or annex set arming is completed automatically at the end of the delay Depending on your system configuration Notes Always make sure that your arming request is followed by the arming tone Always disarm the system when re entering the premises NB On some keypad models presenting the TAG for more than 2 seconds will arm the system without pressing the Arm key ARMING WITH FAULT If the system diagnoses a fault on arming you cannot set the alarm Faults include system faults
11. DOMONIAL Il USER MANUAL SI Congratulations on the purchase of your DOMONIAL security system This system is designed to operate on an authorised radio frequency and will in no way endanger the user To make the best out of your system we advise you to read this manual carefully Introduction to the security system 0 4 Understanding the system tones 6 J How to use the keyfob with 1 LED 2 6 How to use the keyfob with 3 LEDs ________ 28 Maintenance and recommendations 3 4 Optional your installation may include one or more controlling devices and or one or more detectors Introduction to the security system The Domonial control panel communicator unit is the brain of your security system It exchanges information with the associated wireless peripherals The control panel centralises the data sent by the detectors records the arming and disarming operations and communicates with your Alarm Company The control panel also includes a speaker for alarm signalling and audio verification CHARACTERISTICS RADIO e Narrow band frequency modulation e Identification code specific to each component no possible interference between neighbouring systems e Protection against attempted jamming e Radio monitoring of the system detectors and sirens ELECTRICAL e 240V mains with battery backup e Built in voltage surge protection e System supply monitoring TRA
12. NSMISSION e Built in telephone transmission e Telephone line loss detection e Transmission monitoring by periodical tests e Optional GSM transmitter OPERATIONAL Up to 3 protected sets total set partial set annex set Up to 30 detectors Alert functions e e o e Control panel and detectors protected against tampering INDICATOR LIGHTS The front cover of the control panel features LED indicators which show the status of your security system Db A 7 E lt uri a Indicators 2 3 4 and 5 show the faults which are occurring or in memory for one set at a time Indicators are only active when the system is unset and during the arming and disarming phases When the system is set the indicator lights turn off after a few seconds 1 LED INDICATOR SYSTEM ARMED On Total set is being armed Flashing slowly Partial set is being armed Flashing quickly Annex set is being armed Off The system is disarmed On Faults indicated on LEDs 3 4 and 5 correspond to the total set Flashing slowly Faults indicated on LEDs 3 4 and 5 correspond to the partial set Flashing quickly Faults indicated on LEDs 3 4 and 5 correspond to the annex set OFF Faults indicated on LEDs 3 4 and 5 correspond to the entire system 3 LED INDICATOR SYSTEM FAULT css On A system fault is occurring on set indicated on LED 2 System faults include battery or power failure supervision fault phone line failure or radio Jamming
13. de The control panel picks up your call after the number of rings configured by the installer or after it has been called twice in succession REMOTE ACCESS TO YOUR SECURITY SYSTEM Dial the phone number of your security system A 2 second beep is emitted followed by the Arpeggio invitation tune You then have 30 seconds to enter your 001234 by default secret code 1 gt lt A high pitched beep confirms that the code i is valid You are then connected to your High pitched security system REMOTE ARMING You can arm a set over the phone if the system has not been programmed to arm once the final door is closed Total arming x 2 1 Press keys 2 1 for total set arming Part arming gt Press keys 2 2 for partial set arming E 2 2 Press keys 2 3 for annex set arming Annex zone arming gt Arming is confirmed as soon as you hear IEE a tune REMOTE CONTROL OF ELECTRICAL EQUIPMENT You can activate deactivate up to 12 electrical appliances lights etc from a distance using a telephone Key in plus the number of the appliance 101 to X112 using the keypad gt One short beep informs you that your appliance is active gt Two beeps inform you that your appliance is not active SELECTION of the appliance E E ro Si MO To turn the appliance on press 1 To turn the appliance off press 0 This function requires an optional X10 e
14. e the messages and continue the arming process gt Memorised faults are cleared from the memory and faults currently occurring are bypassed Press Gj to cancel the arming process When faults are present or in the memory after you have disarmed the system they are indicated by an icon and a message on the keypad screen INTRUDER TOTAL SET END OF FAULTS Press to clear faults in the memory and reset the system Press again to review the list of faults currently occurring c Press to exit the screen See also System Lock below SYSTEM LOCK ES After a confirmed alarm your system requires an operator reset Call your alarm company The operator will provide the remote reset code based on the code displayed on the keypad SYSTEM LOCKED UNLOCK SYSTEM INTRUDER PLEASE ENTER TOTAL SET RESET CODE SYSTEM LOCKED SYSTEM RESTORED THE USERS MENU The USERS item is a very important item in the menu because all users must key in their code or present their TAG in order to make any settings or adjustments to the system or to access information about system status Note that some menus are only available using the Master Code or TAG ADDING OR MODIFYING CODES You can add codes or modify existing codes but all new codes must be at least 2 figures higher than any existing codes gt For example if a code for an existing user is 2345
15. equipment from a distance see Remote Control of Appliances page 29 This keyfob is optional but 1 to 10 keyfobs of this type may be included with this system It comes with a carrying strap for attachment to a keyring ARMING OF THE TOTAL OR PARTIAL SET Note that with this keyfob arming is immediate Only arm the system once you are outside the area to be protected To arm the Total or Partial set Press the Total or Partial arm a button gt The associated light blinks during communication with the panel and remains lit for 3 seconds to confirm that the system is armed gt The arming tone is emitted by the panel siren ARMING WITH FAULT If the system diagnoses a fault on arming you cannot set the alarm Faults include system faults tampering and triggering of detectors gt A tone indicating a fault is emitted by the panel siren after the arming request instead of the arming tone Check that all doors and windows equipped with detectors are closed lt gt You can override prevention of arming by requesting arming a second time within two minutes of the first request This will bypass all faults gt The arming process restarts ARMING OF THE ANNEX SET If the system is set up with an Annex Set lt gt To arm the Annex Set press and amp simultaneously To disarm press 6 and GJ simultaneously DISARMING To disarm the Total and or the Partial Set pres
16. for 3 seconds CHECKING THE STATUS OF YOUR SYSTEM To check the status of your system press the control button G for 1 second gt All three LEDs light several times in succession and then the LED for the current arming status remains lit for 3 seconds PERSONAL ATTACK This function is optional and can be set up at installation You can call for assistance at any time even when your system is not armed Press buttons and 3 simultaneously for 2 seconds gt Depending on the configuration the siren may be triggered Your alarm company is alerted CHANGING THE BATTERY When the battery starts to run down instead of remaing fixed the LEDs will fade out gradually Insert a small screwdriver into the space in the back of the casing as shown in the illustration Push with the screwdriver while levering upwards and the front of the casing will release lt gt Use the screwdriver to push the old battery gently out of its housing and slide the new battery into place To close the casing insert the lower part of the front into the rear casing then slide the upper portion into place and press firmly until it clicks WARNING There is a risk of explosion if the correct battery is not used Replace only with battery type CR2032 Panasonic or GP Understanding detector operation D PIR DETECTOR A PIR detector is a moti
17. iren if set up Depending on the configuration of your keypad this will disarm the Total Set or the entire system In the latter case the annex set might need to be rearmed Disarming the system will also stop the sirens if you have accidentally triggered an alarm In certain circumstances you may wish to cancel the arming process before the system has finished arming In this case press to disarm Stopping the siren does not interrupt the transmission to the alarm company PERSONAL ATTACK The activation of this function is optional and can be performed at installation If set up on your system you can send an alarm at any time Press the Total and Partial arming keys simultaneously Depending on the configuration of your keypad this action will result in gt An alarm being sent to the alarm company gt The siren being triggered FAULTS ON DISARMING INCORRECT CODE OR INVALID TAG After five attempts to enter a 4 or 6 digit code the keypad locks out all users for five minutes If an invalid TAG is touched to the keypad the screen displays IDENTIFICATION ERROR After five attempts to use the TAG the keypad locks out all users for five minutes FAULTS ON ARMING When faults are present or in the memory while you are trying to arm the system they are indicated by an icon and a message on the keypad screen TAMPERING ALL SETS OVERRIDE Press to acknowledg
18. isarm it using a valid code or programmed key TAG If there is more than one alarm in the memory repeat this operation for each alarm until light 3 4 or 5 stops flashing slowly if LEDS p is flashing quickly on your alarm panel a confirmed alarm has occurred and a reset must be performed by your alarm company otherwise you cannot operate the system Call the operator INCORRECT CODE PROTECTION PERSONAL ATTACK PROGRAMMING FUNCTIONS IF YOU ENTER 5 SUCCESSIVE INCORRECT CODES THE KEYPAD IS BLOCKED FOR 5 MINUTES This function is optional and can be set up at installation You can send an alarm at any time even when your system is not armed Press and hold and O simultaneously gt The siren is triggered depending on the configuration gt The alarm company is alerted WARNING The system will automatically exit programming mode after 15 seconds if no keys are pressed during this period and the red light will time out If this occurs you must repeat all the steps necessary for the function you are using CHANGING OR SETTING ADDITIONAL CODES The keypad can have up to 10 users User 1 has the master code or master TAG and is the only person who can add or modify users To change or set additional user codes you need to enter programming mode Press and simultaneously gt The red light will flash slowly Enter the master code or present the master TAG NB User 1 is always the
19. nnex set armed Annex set disarmed g 0 Receiver 1 ON rg yf p Receiver 2 ON Alarm in memory Power supply fault XKae DB Please contact your installer if these faults persist Tamper fault Radio transmission in progress ego System fault 9 MI oto State of keypad battery A M Blinking replace keypa battery ri Message area Silent mode p Menu scrolling and eypisogidetedor choice validation Detector activated The TCU display clears after a few seconds in order to save energy THE TCU MENUS THE MAIN MENU I ANNEX 2 EVENTS 3 TOOLS 4 USERS a TESTS E PREFERENCES V VV VV VvV Yy Press the p GD keys to enter the main menu Navigate through the menus with and GD Confirm your choices with Abort your choice with Return to the main menu with THE SUB MENUS ANNEX This menu is used to arm or disarm the Annex set See Arming of the Annex Set on page ll EVENTS The security system records events with their time and date These can be viewed from the keypad when the system is disarmed TOOLS This function allows you to control receivers detectors and so on Refer to The Tools Menu on page 17 for complete instructions USERS Use this function to specify the users of your installation The master user must be identified by his code or TAG This menu item is described in detail in The Users Menu on page 15 TESTS You can initiate tests of yo
20. on detector that reacts to the temperature fluctuations caused by a person in motion If the detector s light indicator is set up it will flash when movement is detected In order to save the batteries of the wireless detectors the next detection will be delayed for a few minutes So the indicator will flash again only after a few minutes of rest DOOR CONTACT A door contact is a magnetic contact with two parts One part is attached to a door frame and the other to the door itself When the door or window is opened the detector is triggered Before leaving the premises always make sure that all openings are properly closed When arming your security system triggering of a detector will be indicated if one or more contacts outside the exit route are not secured GLASS BREAK DETECTOR A glass break detector analyses the various frequencies emitted by breaking glass SMOKE DETECTOR A smoke detector mounted on the ceiling ensures the coverage of about 50 square metres Refrain from smoking in the vicinity of this detector SMOKE DETECTOR A shock detector mounted on a window or doorframe detects the vibrations caused by forced entry How to control your system over the telephone Control of your system over the phone is only possible from a multi frequency tone dialling or cellular phone This function must be configured by the installer Remote control is authorised only after you have entered a valid co
21. s local beeps To set Silent Mode Select 6 PREFERENCES in the MAIN menu then select Silent Mode using G amp D Gs to move up and down Select Active Inactive or Partial Set only using GQ GD then confirm your choice with A keypad beep confirms your settings Press to return to the Preferences menu SETTING THE CHIME When a chime is set up for doors equipped with door contacts the panel chime can be activated using the keypad Please note that when activating the chime the silent mode is automatically set to inactive To set the Chime Select 6 PREFERENCES in the MAIN menu then select Chime using GD E to move up and down In the Chime menu select Active or Inactive using Gp then confirm your choice with A keypad beep confirms your settings Press to return to the Preferences menu ALLOCATING SHORTCUT KEYS This function allows you to allocate a shortcut to the DL keys left and right arrow keys to enable easy access to your most commonly used menu items Select 3 SHORTCUTS in the PREFERENCES menu Select the function to be allocated to the left arrow using the arrow keys and confirm your choice with Repeat the procedure for the right arrow A keypad beep confirms your settings SELECTING THE KEYPAD LANGUAGE This function allows you to select the language to be used for the keypad display Select 4 LANGUAGE in the PREFERENCES menu Select the language u
22. s the disarm button 6 gt The associated light blinks during the communication with the panel and then lights for 3 seconds to confirm the instruction gt The disarming tone is emitted by the panel siren Disarming also stops the siren but does not interrupt the transmission to the alarm company DISARMING AFTER AN ALARM If there is an alarm in your absence When you press the disarm button all three lights blink slowly gt The system will not disarm in order to avoid beeps that could attract the attention of an intruder To confirm disarming press the disarm button again gt The associated light blinks rapidly during communication with the panel then lights for 3 seconds to confirm disarming REMOTE CONTROL OF APPLIANCES This function requires an optional X10 extension with X10 receivers Depending on your needs your installer will advise you on the different options for controlling appliances If this has been configured by the installer you can control up to 4 household appliances however the default is 2 gt The Control button controls the first appliance receiver 1 a 4 The 3 lights blink until the request has been accepted by the system and then 4 remain lit for 3 seconds a gt The Control and Partial Arm buttons control the next appliance receiver 2 G Lights 1 and 2 blink until the request has been accepted by the system and then remain lit
23. sing gt GSD and confirm your choice with A keypad beep confirms your settings INFORMATION amp MAINTENANCE CHECKING THE STATUS Press Enter your code or touch the Tag Identification area of the keypad with your tag The screen displays the following information gt The current arming status gt The current active icons whether blinking or steady gt Faults affecting the system To clear memorised faults and reset the system press To view any other current faults press again When all the faults have been viewed the screen displays END OF FAULTS Press to clear the screen or it will clear automatically after 20 seconds REPLACING THE BATTERY A blinking battery indicator light informs you that the keypad battery needs to be replaced Remove the keypad from its base lt Remove the battery cover by inserting a screwdriver into the slot at the base of the cover and levering upwards as shown in the diagram Replace the battery respecting the polarities and secure the cover Return the keypad to its base WARNING There is a risk of explosion if incorrect batteries are used Replace only with a battery of the same or an equivalent type recommended by the manufacturer Dispose of batteries in accordance with the regulations in force CLEANING THE KEYPAD To clean the keypad use a dry cloth only no detergent Howto use the wireless keypad with prox reader 0
24. t a user with and confirm your choice with Pressing will disable this user s TAG gt Ifyou disable a TAG the name of the owner is struck through THE TOOLS MENU REMOTE CONTROL OF APPLIANCES This function allows you to control remote receivers Select 1 REMOTE PLUGS in the TOOLS menu then select the name of the receiver you wish to modify using Gap to move up and down Confirm your choice with The screen displays one of the states below REMOTES LAMP HALLWAY lt OFF gt Confirm with A keypad beep confirms the change of state of the remote receiver Press to return to the Tools menu LOCATING TCU KEYPADS If a second keypad has been misplaced the SEARCH TCU test will cause a keypad not located in its base to beep If you have only one keypad this function is not active To locate the keypad by phoning the control panel Dial the telephone number of the panel After the music enter your code A high pitched tone confirms your code Press lt 55 gt then hang up The missing keypad beeps MANUALLY BYPASSING DETECTORS This function allows you to temporarily bypass one or more detectors Bypassed detectors are returned to normal operation the next time the security system is disarmed Select 3 BYPASS DETECTOR in the TOOLS menu Enter your User Code or present a TAG Select the name of the detector you wish to bypass using GQ GSD to
25. tampering and triggering of detectors gt A tone indicating a fault is emitted by the panel siren after the arming request instead of the arming tone Check that all doors and windows equipped with detectors are closed You can override prevention of arming by requesting arming a second time within two minutes of the first request This will bypass all faults gt The arming process restarts the arming tone is emitted by the panel siren followed by the exit delay beeps Arming is completed at the end of the delay DISARMING USING YOUR CODE OR TAG To enable you to get to the keypad without triggering an alarm your installer may have programmed an entry delay Enter a valid code or present a programmed TAG A green light on the keypad confirms that the code is valid gt The disarming tone O__ is emitted by the panel siren Disarming the system will also stop the sirens if an alarm is triggered Note Depending on your keypad 5 configuration this will disarm the total set or the entire system In the latter case the annex set might need to be re armed Stopping the siren does not interrupt the transmission of the alarm to the alarm company RESETTING THE SYSTEM AFTER AN ALARM AZ Iflight3 40r5 is flashing slowly on your control panel an alarm has occurred When an alarm is in the memory the system cannot be armed until it has been reset To reset the system simply d
26. ur security system to confirm that it is operating correctly There are three options Sirens lights maintenance Sirens Each siren operates in turn for 5 seconds Lights All indicator lights on the control panel and keypad light for 5 seconds Maintenance This function can be active or inactive depending on your configuration It allows you to control certain functions from a distance See your installer for details PREFERENCES This function allows you to choose various modes of operation and activate or deactivate the panel siren s beeps See The Preferences Menu on page 19 ARMING THE SYSTEM USING YOUR CODE OR TAG Before arming the Total Set ensure that the keypad is in its base Press g Total Set arming or Partial Set arming Enter your user code programmed during installation Refer to The Users Menu p 15 or present your TAG to the TAG reader of the TCU If the system diagnoses a fault on arming a message is displayed Press or press the arming key again to bypass the faults and continue the arming process gt The start of the arming process is signalled by a series of keypad beeps and by the siren if set up gt The screen counts down the exit time remaining and the Total or Partial set arming light comes on to confirm arming ARMING PRESENT TAG OR ENTER CODE To complete Total Set arming close the final door Partial Set arming is completed at the end of the arming delay
27. xtension with X10 receivers TERMINATING THE COMMUNICATION To terminate the communication press Xe and on your telephone Your security system ends the call Maintenance and recommendations e Check your system once a month or according to your operator s specifications e Avoid shocks for all the components and especially avoid dropping the keyfob e Do not immerse in water e Only use a damp rag to clean the components no detergent e Keep ina clean dry place at room temperature e Dispose of old batteries in containers provided for this purpose e Avoid prolonged exposure to siren emissions e Do not hide motion detectors behind curtains furniture etc e Do not paint or paper the components e Do not try to open or move the components They are tamper protected and some of them may cause electric shocks Honeywell Security amp Custom Electronics 1198 Avenue du Docteur Maurice Donat BP1219 06254 Mougins Cedex Sophia Antipolis France Tel 33 0 492 942 950 Fax 33 0 492 942 960 All data and images in this document are subject to change without prior notice Honeywell International Inc EKZ006600F 02 08 Honeywell III
Download Pdf Manuals
Related Search
Related Contents
Omega Drums OMB-DAQ-2416_4AO User's Manual e-leave User's Manual Frigidaire FFRA1222R1 Energy Guide : Free Download, Borrow, and Streaming : Internet Archive FT LLD LESSIVE LINGE DELICAT 21.05.2013 mode d`emploi - Epargnissimo Copyright © All rights reserved.
Failed to retrieve file