Home
User Manual
Contents
1. circuit board
2. E reflective bowl can t touch and lens must be kept clean The light cone stents It is support light cone and connection chassis Knob It can adjust the angle of the body Signal cable passes and send signal Bottom stand the body and inside function Waterproof fan case protect the fan from water Wheels move the equipment easier Waterproof power plug red cable connects Live Wire yellow amp green cable connects earth wire 4 Lamp Installation Instruction Specify Xenon Lamp called Xenon short Arc lamp High pressure In the lamp has the high pressured Xenon In the high frequency pressure arouse formed under the arc discharge It is the small light point source shaft injection from uv to near infrared strongly continuous spectrum visible area very similar to separation of sunlight high frequency shine color temperature 6500 K show color of the high Ra 94 Is television and film lighting the color films stage lighting photographic system board projection amplification meter infrared ray of light and simulation technology ideal light source 5 Operation and Notice When fetch the lamp do not touch the lamp glass envelope before use please clean the lamp by alcohol to avoid influence the light and lifetime of the lamp Please turn on the red switch when you start to use it each switch control an electric rectifier The black switch is control the lamps body spin 1 Install Xenon lamp Install the
3. The Sky Rose Searchlight User Manual e Please read this manual before using 1 Brief introduction The sky rose is one of great product in the outdoor lights area It includes the high science amp technology and arts amp crafts and novelty characteristic It is very easy to be installed and operated by the technician It is suitable for the park big square big building any recreation ground etc 2 Important safety operation Please abide the user manual to use the sky rose Power supply AC 220V 50Hz Plug 3 Pin plug with earth wire Please confirm the sky rose connectAC 220V 50Hz power supply The lamp power source plug should has the earth wire Please cut off the power supply immediately when the below situation happen Then check up and repair it by the special technician When cooling fan refuse working power supply cable and other cable damaged Lamp cannot turn on There are abnormity phenomena during its working Operate the light according to the manual but the light still cannot work normally Notice During the machine start work as for the cooling system start working there will be some noise and when the lamp start also will be some noise In general this will be a short time 3 Spare Parts Description Aluminum body Use aluminum alloy material waterproof rust heat dissipation quickly Reflective bowl it used the high grade shock resistance materials can make the highest lamps brightness output NOTIC
4. cathode onthe lamp chimney following lamp stand steady and fastness Install the anode on the front which is the light emit can follow Xenon flash lamp axis stretching Please remember Avoid fixed only one end and the other end is suspended low wattage lamps may allow fixed one end Fastening on both sides must allow free extension Xenon lamp cannot have any pressure or collision under any condition installation adjust clean or so on 2 Xenon lamp light positions both vertically and horizontally perpendicular to the vertical light should be Tilt is not more than 5 and the anode at the top is connected positive electricity Level when lit must increase the magnetic field magnetic field transverse magnetic field dimensionally stable arc vacuum arc can be taken both magnetic fields are used in conjunction arc stability of magnetic field polarity must be correct magnetic field strength must be moderate the show is under constant observation finds the problem timely adjustment Use after a certain time lights should be turned a certain angle to increase lamp life 3 Xenon lamp must be current ripple pulsating coefficient greater than 3 5 under the DC power supply is lit otherwise it will affect lamp life seriously 4 Xenon lamp and conductor contact surface should smooth good contact to prevent contact resistance in order to ensure a good contact you must check the contacts on a regular basis 5 Xenon la
5. high or low voltage will affect controller or can t work normally 4 Do not use gasoline or other chemicals to wipe lamps 5 Do not replace any parts without authorization 6 Do not cover the light during it working 7 Needs to repair or when the replacement components must the dump waiting for lamps cool completely only then can carries on 8 Has any question or the technical question about the lamps please look for the specialists or the supplier 9 For your long time use PLS keep the performance time less than 4 hours 6 Start The Lamps Wired up the power turn on the red switch one red switch control 1000w Black switch control lights horizontal scan 7 Skill Specification specification 2KW 3KW 4KW SKW parameter Power supply 220V 220V 220V 220V Other parameter Light life 800Hours IP rate IP44 outdoor use Color White Yellow Blue Green Red Color Temperature 6500 K Color rendering index Ra gt 94 Dimensions 69x58x101cm NOTICE Xenon lamp s characteristic and application method The xenon lamp is electric discharge and stimulate bubble lamps The light effect is 30 40 Im per watt The tube luminophor is small is the point source is advantageous in the optical system design The contact conductor should contact good the electrode do not connected reverse The light bulb installment should not receive external forces torsion force pulling force in order to avoid tube break The t
6. mp life has close relations with switching frequency switching less life expectancy increases in turn accelerated bulb blackening shorten life expectancy 6 Xenon lamp to maintain good ventilation to power large more than 1500W of lights to be carried out with sufficient air flow forced air cooling General Yin extreme wind horizontal light Xenon lamp reflector middle hole air valid and reasonable 7 Above 2000w lamp should uses the dismountable electricity wiring When installs it two spanners should be used one support on both sides the hat gap another tighten the hexagonal nut When the assembling and dismantling does not allow to have the stress or barbaric action 8 Xenon lamp belongs to the high pressured electric discharge electric lamp Please make sure the barometric pressure is in the high pressure before it work and work time And must avoid the shock When installing and uses the worker must wear the protecting mask and glove The lamp should be put in the radiation good heat dissipation to avoid soaks the shell breakage and the strong luminous intensity ultraviolet ray burns the skin and eye NOTICE 1 Before work please check whether the lamp logo match to the actual 2 In the installation process please cut off the power source first not installed the good lamps can not be link to electrify 3 Please check whether installation well and the power is in accordance with the requirements the input voltage ofAC 220V 50Hz
7. ube actual use power do not surpass the rated power simultaneously should have the suitable heat radiating in order to avoid the lamp damaged The light bulb spheroid must maintain clean refuses to touch barehanded in order to avoid greasy dirt dust contamination If with dirt please clean it by cleaning ethyl alcohol lint ball in order to avoid lamp burning the spheroid shell lose permeability even explode 8 The Maintenance And Cleaning Equipment fouling phenomenon usually appears in different levels after a period of time normal operation of the lamp being dirt will not conducive to the future So we strongly recommend you to regular maintenance and cleaning products regular time to use the environment and the operating frequency and decide usually within a month at least clean again In the lamp before cleaning please disconnect the lamp power In the lamp firmly fixed steady state for maintenance and cleaning Open the lamp cover the lamp reflector glass and other glass products cleaning And then do the cleaning work on the circuit board fan power supply and other electronic components Please note electronic components can not be cleaned with cleaning fluid or liquid materials with water cleaning tool Recommend the use of soft cloth or a professional cleaner to clean under any circumstances can not use alcohol or solvent When cleaning please be gentle force in order to avoid damage to parts especially glass and
Download Pdf Manuals
Related Search
Related Contents
Star Motorcycles YZFR6X(C) Automobile User Manual RCA Stereo Receiver with Remote Control Stereo Receiver User Manual Agilent Stethos Electronic Stethoscope Mode d`emploi AS 620KM Copyright © All rights reserved.
Failed to retrieve file