Home
Manual
Contents
1. be operated as intended The specific standards applicable to this product are detailed in the appendices Since there are many electrical products in use that pre date this Directive and may emit electromagnetic radiation in excess of the standards defined in the Directive it may be appropriate to check the analyzer prior to use The following procedure should be adopted 1 Go through the normal start sequence in the location where the equipment is to be used 2 Switch on all localized electrical equipment that might cause interference 3 Check that all readings are as expected Generally a low disturbance is acceptable If not adjust the position of the instrument to minimize interference or switch off the offending equipment during the test There has been no awareness of any field based situation where such interference has ever occurred since the writing of this manual April 1998 This advice is only given to satisfy the requirements of the Directive This product has been tested for compliance with the following generic standards and it is certified to be compliant EN 50081 1 EN 50082 1 Specifications EC EMC K1 CD100A details the specific test configuration performance and conditions of use T CDIO0A Combustible Gas Leak Detector Limited Warranty The CD100A is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase If within the warranty pe
2. stabilize indicated by a steady tic rate It may require up to two minutes to stabilize The unit responds to gas with a variable audible tic sound The audible tic increases in volume when exposed to gases with 50 parts per million or more When gas is detected the tic rate will increase rotate the thumbwheel back to the steady tic resetting the instrument to this new background level Move the instrument into higher concentrations of gas indicated by increase tic rate until the leak is found The Tip Light is used to see around the area of the leak in a dark environment When this instrument is used in noisy environments look at the red LED which flashes more rapidly as the tic rate increases The optional earphone can be plugged into the side of the unit if there is high background noise or the operator does not want to disturb other people This also disables the speaker If the tic rate becomes uncontrollable it may be necessary to change the sensor The detector will respond to some leak finding solution soap SO use your detector first If over exposed to some gases the detector may take an extended period of time to return to normal Battery Replacement 1 Turn off the power and remove the battery case cover 2 Remove and dispose of old 9V alkaline battery promptly in a manner consistent with disposal regulations Always use a 9V alkaline battery Ensure the polarity of the battery match
3. Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com K INSTRUCTION MANUAL CD100A COMBUSTIBLE GAS LEAK DETECTOR TIC LOW BAT PWR CD100A a p me 5l a alae Lg Combustible Gas Leak Detector A B G GIA GA A 2 ai ein LOTT TT TES N Introduction The CD100A Combustible Gas Leak Detector is capable of sensing many combustible non combustible and toxic gases that include but are not limited to the following Acetone Industrial Solvents Alcohol Jet Fuel Ammonia Lacquer Thinners Benzene Methane Butane Naphtha Ethylene Oxide Natural Gas Gasoline Petrol Propane Halon Refrigerants Hydrogen Sulfide Toluene NOTE This leak detector is factory calibrated for methane in air WARNING This unit should not be used for detection of Carbon Monoxide Features include e Fully adjustable steady tic rate accelerates as the sensor tip approaches a leak the adjustment knob ts located on the side of the unit e Tip Light in sensor cover used to see around the are of leak in a dark environment e Long 18 flexible gooseneck e Audible and visual leak indicator e Low battery indicator and separate battery compartment for easy replacement e Power On light e Solid state semiconductor sensor provides instantaneous det
4. ection e Sensor cover to protect sensor e Ruggedized protective rubber boot e Socket for optional earphone e One year limited warranty Safety Tips Before using this detector read all safety information carefully In this manual the word WARNING is used to indicate conditions or actions that may pose physical hazards to the user The word CAUTION is used to indicate conditions or actions that may damage this instrument eo Charging or discharging batteries may give off an explosive gas Keep away from open flame and sources of ignition from the battery at all times FRANNA_AAAAI International Symbols By mens T Fi AC l l Alternating Current Warning or Caution E Double Insulation Direct Current LI Protection Class II Not Applicable to Identified Model Battery Operating Instructions Turn the instrument on by rotating the thumwheel downward in a non contaminated environment fresh air The green power LED will be illuminated when the unit is turned on If the battery level is low the red LED will be steady and the tic will not be adjustable The battery will need replacing Adjust to slow uniform tic rate with the use of the thumbwheel approximately two tics per second This sets the instrument to the background level Start your testing by setting the instrument in fresh air The red LED indicator will flash in correspondence with the tic rate Allow about 10 seconds for the sensor to
5. es that shown in the compartment 3 Replace the battery case cover Sensor Filter and Sensor Replacement The sensor is housed at the tip of the gooseneck assembly and has a life of more than three years To remove the sensor 1 Turn the unit off 2 Pull off the top half of the sensor housing Pushing to one side aids removal 3 With care move the Tip Light LED to one side to gain access to the sensor small silver can 4 Unplug the sensor and replace it with a new one NOTE The sensor can be fitted in either one of two ways without affecting instrument operation 5 Realign the LED ensuring it sits above the sensor 6 Replace the sensor cover by pushing it firmly in place Note the locating pin between the body and sensor cap Specifications Visual Flashing LED Battery Life 5 hrs typical use TWF WO Weight 205mm x 100mm x 36mm Probe Length 150z 400mm Protection against electric shock in accordance with EN 61010 1 1993 This instrument is designated as Class IIl SELV FRAANNA_AAAAI Replacement Parts Battery AB10 Replacement Sensor RS1000 Replacement Sensor Cap RS1010 Optional Accessories Headset Earphones HE1000 Hard Carrying Case AC501 Electromagnetic Compatibility The European Council Directive 89 366 EEC requires that electronic equipment does not generate electromagnetic disturbances that exceed defined levels and has an adequate level of immunity to enable it to
6. riod your instrument should become inoperative from such defects the unit will be repaired or replaced at UEi s option This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration tampering accident misuse abuse neglect or improper maintenance Batteries and consequential damage resulting from failed batteries are not covered by warranty Any implied warranties including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warrantywill be repaired when repairable for a service charge Return the unit postage paid and insured to This warranty gives you specific legal rights You may also have other rights which vary from State to state Test Equipment 99 Washington Street Melrose MA 02176 om Al Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431 PLEASE ge vy RECYCLE Copyright 2007 UEi CD100A MAN 1 07
Download Pdf Manuals
Related Search
Manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manual arts high school manually update your device drivers windows manual definition manual for courts martial manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manual transfer switch manualidades manual blood pressure cuff manual handling manual transmission cars for sale manual digital manual pdf manual autopilot enrollment
Related Contents
Jabón natural con leche de burra y manteca de karité, té de rosas ラジオハ聴 `プ スター M。DEL Untitled Uma coleção de “tool presets” - gps-gimp-paint Diamond Multimedia MiniRocker Pelco System 9760 Webcam User Manual ASUS BM BM1AD-I54570072B UPSTAGE USER MANUAL SWING MISTRAL 6 Hike - Betriebsanleitung Deutsch - V0_1 ZENworks 10 Configuration Management-Referenz für die Copyright © All rights reserved.