1. Inglewood 90308 For the CUSTOMER ARCTICA ARCTICA WARRANTY CARD The Most Advanced Aquarium Cooler Please fill out completely and return within 14 days from date of purchase f CUSTOMER NAME Titanium Heat Exchanger ADDRESS Energy Efficient Design PHONE Low Noise Level CITY STATE ZIP Built In Thermostat System PATE OF PURCHASE Compact Footprint Size HORSEPOWER DEALER NAM STATE www jbjlighting com SERIAL No i
2. Inlet Outlet Filter Suction grill Q N controller Exhaust grill 7 Fuse Power plug OTEMPERATURE CONTROLLER AQUARIUM TEMPERATURE CONTROLLER Cooling lamp TEMP SET L o Oo n wu ARCTICA 9 N Figure 2 Part Name for Chiller 9 ODBI 050 D CONTROLLER FILTER SOCKET 1 GASKET SOCKET 2 CHILLER SOCKET 3 G FAN MOTOR Assy 1 MOTOR 2 FAN BLADE FAN MOTOR BRACKET 9 CONDENSER CASE REFRIGERANT COMPRESSOR 9 CABLE BRACKET BASE PANEL 9 TEMO PROBE NC SC E e ce 2 Figure 3 Exploded View and Part Name 10 Send to JBJLIGHTING ARRANTY INFORMATI QT OA W N NFO ON win AROTICA TITANIUM CHILLER 1YEAR LIMITED WARRANTY This JBJ ARCTICA Titanium Chiller is warranted to the original purchaser against defective material i and workmanship for 1 year from the date of original purchase This warranty is valid onl
3. 2 INTRODUCTION Thank you for purchasing the ARCTICA Titanium Chiller This powerful cooling system guarantees consistent water temperatures with the most advanced features on the market All models are specifically designed for longterm performance with proper maintenance and operation and provide the BEST VALUE in the industry Quality 1 Year Limited Warranty on all parts amp labor from the date of purchase Service Qualified technicians are available for topics ranging from chiller sizing performance troubleshooting and providing detailed instructions for maintenance procedures 3 RECEIVING AND INSPECTION Inspect the chiller closely when it is received Record any indication of damage on the delivery receipt especially if the chiller will not be immediately uncrated Obtain the delivery person s signed agreement to recorded damages to facilitate future insurance claims Since the chiller is shipped F O B Factory the manufacture s responsibility for the shipment ceases when the carrier signs the bill of lading If goods are received short or damaged condition notify the carrier and insist on a notation of the loss or damage across the face of the freight bill Otherwise no claim can be enforced against the carrier If concealed loss or damage is discovered notify your carrier at once and request an inspection This is absolutely necessary Unless you do this the carrier will not consider any claim for loss o
4. circulate water through chiller before turning on the unit Check all connections for leaks Verify electricity rating and then plug power cord into a dedicated electrical outlet This unit has been factory set at 77F The light indicator will begin to blink 2 The Digital Display will read the current water temperature Chiller will automatically turn on within 3 minutes 3 4 5 6 T 8 Your chiller has now been activated This unit contains an Auto Digital Temperature Control System This built in thermostat will turn itself on off within 1 F according to the desired set temperature Changing setting temperature Example To change setting temperature rang from 77 F to 79 F mae mue pu Tea mum Press the UP button Decimal Point will Set to desired temperature The new temperature setting for 5 seconds blink Depress the UP setting by pressing UP or Down will blink and be stored in the button once the number buttons memory chip after 10 seconds starts to blink Error representation The thermostat has self diagnostic function so the letters below will be appeared on display if error occurs Please try to check and repair it following the instructions below Indication Descriptions Otherwise contact us for warranty service Lu qm Abnormal signal Please check it if there is any damage to the sensor wiring T1077 5 0 of sensor or water soaked into the joints before repai
5. It is important to keep this appliance clean Always unplug the appliance before performing maintenance or cleaning of the exterior of this chiller Wipe exposed surfaces carefully with a damp terry cloth to remove any dust or mineral deposits which may collect over time Make sure all surfaces are dry before re plugging into an electrical outlet SERVICING In order to assure proper electrical connections and polarity replacement parts and servicing should be performed by a qualified electrician OPERATION Please carefully read the entire Owner s Manual for proper operation procedures before proceeding with turning on this appliance SAVE THESE INSTRUCTIONS 2 1 1 Warning Icons Warning lcons in this manual are boldfaced for emphasis The signal words DA NGER WARNING CAUTION are used to indicate hazard seriousness levels as follow AN DANGER immediate hazard which WILL result in severe injury or death AN WARNING Hazard or unsafe practice which COULD result in severe injury or death 1 2 Data Label The Chiller data label contains identification information If the data label is missing or damaged contact your local distributor and request a replacement un ARCTICA THE EGET ADVANCED ADUARD COOLEEE woll gt Fusa Fira Flow rake ja W x HII eight Water Connection Serial i WOU ATC 151 Peas TOO PAR
6. OWNER S MANUAL MINI ARCTICA TITANIUM CHILLER DBI 050 D SPECIFICATIONS um ARCTICA TI TANI UM CHILLER Power Supply 115Volt 60Hz Ozone Friendly Refrigerant R 134a Distributed by TRANSWORLD AQUATIC ENTERPRISES INC TEL 310 672 0480 FAX 310 672 7261 www jbjlighting com TABLE 5 1 MPORTANT SAFETY INSTRUCTIONS 1 1 Warning Icons 1 2 Data Label 2 INTRODUCTION 3 RECEIVING AND INSPECTION 4 INSTALLATION 4 1 Installation to Aquarium or Tank 4 2 How to Connect Hose 5 GETTING STARTED 5 1 Start Up 6 MAINTENANCE 6 1 Operation To Be Carried Out Every 6 Months Table 1 Chiller Specifications Figure 1 Electrical Diagram Figure 2 Part name for Chiller Figure 3 Exploded View and Part Name 1 IMPORTANT SAFETY INSTRUCTIONS WARNING guard against injury basic safety precautions should be observed including the following READ AND FOLLOW ALL SAFETY INSTRUCTIONS b DANGER avoid possible electric shock special care should be taken since water i is employed in the use of aquarium equipment For each of the following situations do not attempt repairs by yourself return the appliance to an authorized service facility for service or discard the appliance If the ap
7. This JBJ ARCTICA Titanium Chiller is warranted to the original purchaser against defective material and workmanship for 1 year from the date of original purchase This warranty is valid only under the following conditions additions modifications or changes made to the chiller by the purchaser and not by the manufacturer shall void this warranty Damages brought on by abuse misapplication or mishandling also voids this warranty Please refer to the Operation Manual for proper usage TRANSWORLD AQUATIC This warranty is limited to the repair or replacement of the chiller at the discretion of the manufacturer This warranty does not cover personal injury property loss including livestock or damage direct incidental consequential arising out of use of this product This warranty gives you specific rights to you which may vary from state to state Warranty Dept 3730West Century Blvd Suite 6 This warranty card must be filled out completely and returned within 14 days from the date of purchase Failure 1o do so will void this warranty A proof of purchase from an authorized dealer must be provided when making a warranty claim Upon discovery of defect call 310 672 4099 310 672 4021 for authorization Number Inglewood CA 90308 AI waranty cime wil requie prepaid shiping Transworld Aquatics Enterprises Inc 3730 Unit 6 West Century Blvd Se cutting plane line
8. of the filter Remove the filter and with a vacuum cleaner or jet of air to clean dust and debris from impeding air flow Cleaning of the Heat exchanger The elimination of deposits of impurities bacteria or metabolic waste not captured by the pre filter are vital for the performance of this chiller Circulate clean water in the opposite direction through heat exchange chamber for 30 minutes Table 1 CHILLER SPECIFICATIONS ITEM MINI Model DBI 050 D Horsepower 1 15HP BTU 900 BTU h Amps 2 0A Voltage 115V Fuse Size 5A 250V Flow rate 110 160 gal h Dims W x D XH 7 7 X12 6 x 14 1 Weight 28 66lbs Water Connection 1 2 ELECTRIC WIRING DIAGRAM MODEL DBI 050 D INPUT VOLTAGE AC115V 1Ph 60Hz t FUSE 250VAC Connector Female 2P Red fonnector Male 4 PCB 1 1 I 24VDC POWER CORD 18AWG 3C 1 85M SKYBLUE Connector Female 2P Blue SKYBLUE onnector Male 2P coo O H H 8 Male 2 EBE Connector 2P TEMP SENSOR TEMPERATURE CONTROLLER agi Nan ah Figure 1 Electrical Diagram ODBI 050 D
9. pliance falls into the water DON T reach for it First unplug it and then retrieve it If electrical components of the appliance get wet unplug the appliance immediately Carefully examine the appliance after installation It should not be plugged in if there is water on parts not intended to be wet Do not operate any appliance if it has a damaged cord or plug or if it is malfunctioning or has been dropped or damaged in any manner To avoid the possibility of the appliance plug or receptacle getting wet position aquarium stand and tank to one side of a wall mounted receptacle to prevent water from dripping onto the receptacle or plug A drip loop shown in the figure below should be arranged by the user for each cord connecting an aquarium appliance to a receptacle or the connector if an extension cord is used to prevent water traveling along the cord and coming in contact with the receptacle If the plug or receptacle does get wet DON T unplug the cord Disconnect the fuse or circuit breaker that supplies power to the appliance Then unplug and examine for presence of water in the receptacle Close supervision is necessary when any appliance is used by or near children d To avoid injury do not contact moving parts or hot parts such as heater reflectors lamp bulbs and the like e Always unplug an appliance from an outlet when not in use before put
10. r damage The carrier will make an inspection and may grant a concealed damage notation If you give the carrier a clear receipt for the goods that have been damaged or lost in transit you do so at your own risk and expense The manufacturer is willing to assist you in collecting claims for loss or damage Willingness does not make the manufacturer responsible for collecting claims or replacing material Claim filing and processing is your responsibility Eds 4 INSTALLATION Place the chiller in a ventilated place and away from sources of heat making sure that the front and rear of the chiller have at least 1 foot clearance for air flow The chiller must have proper air flow to function correctly DO NOT PLACE INSIDE AQUARIUM STANDS THAT ARE ENCLOSED 4 1 Installation to Aquarium or Tank 1 Connection of outside 2 Connection of circulation 3 Connection of inside circulation pump pump in the filter circulation pump 4 2 How to Connect Hose 1 method of connecting hose to chiller Unscrew socket 1 Q Insert hose tube into socket 1 9 Insert hose tube into gasket Screw onto chiller and hand tighten 2 Checking equipment connection These units have been performance tested and may contain moisture in the heat exchange chamber Hose Tubing Not Included Socket 1 Gasket Chiller Thread 5 GETTING STARTED 5 1 Start Up 1 Once all connections are made
11. ring M Overcooling Please check it if the water temperature is below 5 C celsius degree ES the sensor is out of order or there is bad connection before repairing ircui Please check it if there is short circuit due to pressed or Eg Short circuit uit du torn sensor wire before repairing E 27 Disconnection Please check it if the sensor wire is disconnected before repairing 6 Calibrating Water Temperature with Temperature Controller It is recommended that you calibrate your chiller to your current water temperature upon intial installation Example The actual water temperature is 65 F but the thermostat indication is 70 F The actual temperature differs from the thermostat indication Calibration Procedure Ss ep TER TEE ee qu gt Press the UP DOWN buttons Depress both buttons when CA changes The newly calibrated simultaneously for 5 seconds CA to numbers The numbers on the display is temperature setting will blink will appear on display screen a reading of the current water temperature and be stored in the memory from the chiller s integrated probe chip after 10 seconds Calibrate to your tank s current water temperature by pressing the UP or DOWN buttons and depress 6 MAINTENANCE WARNING Always unplug the chiller from the electrical outlet when performing maintenance procedures 6 1 Operations To Be Carried Out Every 6 Months Cleaning
12. ting on or taking off parts and before cleaning Never yank cord to pull plug from outlet Grasp the plug and pull to to disconnect f Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing h Make sure an appliance mounted on a tank is securely installed before operating it i Read and observe all the important notices on the appliance j If an extension cord is necessary a cord with a proper rating should be used A cord rated for less amperes or watts than the appliance rating may overheat Care should be taken to arrange the cord so that it will not be tripped over or pulled k This appliance has a polarized plug one blade is wider than the other As a safety feature this plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician Never use with an extension cord unless plug can be fully inserted Do not attempt to defeat this safety feature 1 Make sure the chiller is not allowed to overheat chiller MUST have a minimum clearance of 1 foot before the intake of condenser and 1 foot behind the exhaust to evacuate heat m Chiller should NOT be placed inside a cabinet stand This will impede air flow and may reduce the efficiency of the chiller and may cause permanent damage to appliance n Always check water connections before operation for leaks CLEANING
13. y under the following The Most Advanced Aquarium Cooler conditions additions modifications or changes made to the chiller by the purchaser and not by the manufacturer shall void this warranty Damages brought on by abuse misapplication or mishandling also voids this warranty Please refer to the Operation Manual for proper usage Titanium Heat Exchanger This warranty is limited to the repair or replacement of the chiller at the discretion of the manufacturer 2 A This warranty does not cover personal injury property loss including livestock or damage direct incidental or Energy Efficient Design consequential arising out of use of this product This warranty gives you specific rights to you which may vary Low Noise Level from state to state T This warranty card must be filled out completely and returned within 14 days from the date of purchase Failure Built In Thermostat System to do so will void this warranty A proof of purchase from an authorized dealer must be provided when making a Compact Footprint Size warranty claim Upon discovery of a defect call 310 672 4099 310 672 4021 for an authorization Number warranty claims will require prepaid shipping to Transworld Aquatics Enterprises Inc 3730 Unit 6 West Century Blvd Inglewood CA 90308 www jbjlighting com SERIAL No 22 WARRANTY INFORMATION HERE ARCTICA TITANIUM CHILLER 1YEAR LIMITED WARRANTY