1. Manual button and receiver at the bottom of the machine NOTE All the pictures in this manual are for explanation purposes only The actual shape of the indoor unit you purchased may be slight different on front panel and display window The actual shape shall prevail Names of parts CANOAPRWNS gt Of 10410 ooy 5 Indoor unit Front panel Air inlet Air filter Air outlet Horizontal air flow grille outside Horizontal air flow grille inside Vertical air flow louver Display panel Manual control button and receiver 10 Intelligent eye detector on some models Outdoor unit 11 Connecting pipe 12 Connecting cable 13 Stop valve Indication lamp TEMPERATURE indication lamp Displays the temperature settings when the air conditioner is operational Displays the malfunction code Displays the actual room temperature on Fan only mode INTELLIGENT EYE indication lamp Optional Lights up during Intelligent eye operation except when the machine is defrosting This indication lamp continues flashing when the unit detects human activity TIMER indication lamp Lights up during Timer operation ION indication lamp optional Lights up when Clean Air feature is activated DEFROST indication lamp Enabled on cooling amp heating models only Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation OPER
2. sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground water and find their way into the food chain SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage the following instructions must be followed Incorrect operation due to ignoring of instructions may cause harm or damage The seriousness is classified by the following indications AwarNinc This symbol indicates the possibility of death or serious injury A CAUTION This symbol indicates the possibility of injury or damage to property Meanings of symbols used in this manual are as shown below S Strictly prohibited __ J r 3 e Do not extend the cable and never use e Remove all dirt from the power plug and multiple plugs A poor electrical connection plug it firmly Soiled plugs can cause fire poor insulation or voltage which is higher or an electric shock than permitted can cause fire e Inthe event of any abnormalities such Do not expose your body directly to the cool as smell of burning immediately switch air for prolonged period off the device and pull the plug Contact Never poke fingers sticks or other objects your service partner in the air inlet and outlet vents e Always switch off the device and pull the e Never attempt to repair relocate modify the plug before you start to clean it air conditioner yourself Al
3. stops with a clicking sound 2 Take hold of the handle of the air filter and lift it up slightly to take it out from the filter holder then pull it downwards 3 Remove the AIR FILTER from the indoor unit Clean the AIR FILTER once two weeks Clean the AIR FILTER with a vacuum cleaner or water then dry it up in cool place CARE AND MAINTENANCE NE 4 Remove the Air Freshening Filter from its supporting frame on some models e Clean the air freshening filter at least once a month and replace it every 4 5 months e Clean it with vacuum cleaner then dry it in cool place 5 Install the air freshening filter back into position 6 Insert the upper portion of air filter back into the unit taking care that the left and right edges line up correctly and place filter into position Replacement of air filter and air freshening filter 1 Remove the air filter 2 Remove the air freshening filter 3 Install a new air freshening filter 4 Reindstall the air filter and securely close the front panel Preparation for extended non operation If you plan to idle the unit for a long time perform the following 1 Clean the indoor unit and filters 2 Operate the fan for about half a day to dry the inside of the unit 3 Stop the air conditioner and disconnect power 4 Rem
4. ATING INSTRUCTIONS Special functions Refrigerant Leakage Detection With this new technology the dipsplay area willappear EC when the outdoor unit detects refrigerant leakage Louver Angle Memory Function optional Within the scopeof safety angle it will memorize the open angle of horizontal louver If it exceeds it will memorize the boundry ofsafety angle Inthe following circumstances it will returnto standard angle 1 pressing the manual switch 2 unplugand then plugin the machine Sowe strongly suggestthat the openangle of the horizontal louver should not be settoo small incase the condensed water forms and drops from the horizontal louver SELF CLEAN function Optional Function used afterthe Shut Downof cooling operationto clean the Evaporator and keep itas fresh forthe next operation The unit willoperate as following sequence FAN ONLY mode at Lowfan speed Heating operation with LOW fan speed applicable to cooling amp heating modles only FAN ONLY operation Stop Operation Turn off Note This function is only available under COOL AUTO COOL FORCEDCOOL and DRY mode Before select the function it isrecommended to runthe air conditionerunder Cooling operation for abouthalf an hour Once the Self Clean functionis activated all TIMER setting will becancelled During Self Clean operation when press the SELF CLEAN button on theremote controller again willstop the operationand turn offthe unit automaticall
5. The design andspecifications are subjectto change withoutprior notice for product improvement Consultwith the sales agency or manufacturer for details 2020001B7769 Before using your air conditioner please read this manual carefully and keep it for future reference INVERTER SPLIT TYPE ROOM AIR CONDITIONER MSE Ra Sm AMAL PRIDI M POSO97EL POS 1IZ7EL POS187EL POS247EL PWS097EL PWS127EL PWS187EL PWS247EL Read This Manual Keep this manual where the operator can easily find them Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service CONTENTS SAFETY PRECAUTIONS Warning Caution NAMES OF PARTS farelere meo aN a E E E A A A TTS 5 UTA OOK AUTOT EE E E A OE E E E 5 indication Hamp sae ic sciences I s ac daer aa E E Ea Aa aaa 5 OPERATING INSTRUCTIONS Special functions Operating temperature Manual operation Airflow direction control How the air conditioner works CARE AND MAINTENANCE Before maintenance o anssi eadein daen EE dees ea A hansen Asada 10 Cleaning the unit Cleaning the air filter and air freshening filter Replacement of the a
6. air outlet as the efficiency of the air conditioner may be reduced and the air conditioner may stop running e Clean the air filter periodically otherwise cooling or heating performance may be reduced Do not operate unit with horizontal louvre in closed position CARE AND MAINTENANCE Before mainatenance Front panel and louver closing properly Before mainatenance eTurn the system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Power supply must be disconnectd before Front panel and louver closing improperly cleaning the indoor unit ZX CAUTIONS Acloth dampened with cold water may be used on the indoor unit if it is very dirty Then wipe it with a dry cloth Do not use a chemically treated cloth or duster to clean the unit Do not use benzine thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform Never use water hotter than 40 C 104 F to clean the front panel it could cause deformation of discoloration Care and Maintenance Cleaning the unit wipe the unit with a soft dry cloth only If the unit is very dirty wipe it with a cloth soaked in warm water Cleaning the air filter and air freshening filter A clogged air filter reduces the cooling efficiency of this unit Please clean the filter once every 2 weeks 1 Lift the indoor unit panel up to an angle until it
7. emitted air e Never step onto the outdoor device and never place anything on it e Never use an unsteady or rusty base e Never install the air conditioner in places where combustible gas can be emitted Emmitted gas may collect and cause an explosion e Never allow the air conditioner to run for too long with the doors or windows open or if the humidity is very high Ne SAFETY PRECAUTIONS CAUTION Sy If the air conditioner is to be used in conjunction with other heaters the air should be refreshed periodically otherwise there is a risk of lack of oxygen Always pull out the power plug if the unit is not going to be used for any lengthy period of time Collections of dust can cause fire Always switch off the air conditioner and pull out the power plug during a storm Electrical parts may get damaged Check that the drainage line is correctly connected If not water will escape Check that the condensation water can run off unhindered It may cause water damage if the condensation water cannot run off properly The air conditoner must be earthed in accordance with the local codes For electrical safety purposes we recommend that you install an earth leakage circuit breaker If the power cord is damaged it must be replaced by the manufacturer its service agent or similary qualified persons in order to avoid a hazard NAMES OF PARTS Parts names
8. ir filter and air freshening filter Preparation for extended non operation Pre season inspection TROUBLESHOOTING TIPS Normal function of the air conditioner sssini ennienni eniai inina ain 12 Troubleshooting gude sssersseironiuis a aae a a AN aN EEEN A AE aN E 14 When using this air conditioner in the European countries please read the following information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision DISPOSAL Do not dispose of this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities A The municipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacturer will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be
9. mote Controller Operations see the lt lt Remote Controller Instruction gt gt packed with the unit for details Operating temperature Airflow direction control Mode i i i i i i Temperature Cooling operation Heating operation Drying operation Room temperature 17 C 32 C 0 C 30 C 10 C 32 C 62 F 90 F 32 F 86 F 50 F 90 F 0 C 50 C Outdoor temperature 32 F 122 F 15 C 30 C 0 C 50 C 15C 50C 5F 122F 5F 86 F B2 F 122F For the models with low temperature cooling system NOTE 1 Optimum performance will be achieved within these operating temperatures If air conditioner is used outside of the above conditions certain safety protection features might come into operation and cause the unit to function abnormally 2 If the air conditioner runs for a long timein cooling mode and the humidity is high over 80 condensed water may drip out of the unit Please sets the vertical air flowlouver to its maximum angle vertically tothe floor and set HIGH fan mode Suggestion For the unit adopts an Electric Heater whenthe outside ambient temperature is below 0 C 32 F we strongly recommend you to keep the machine plugged inorder to guarantee it running smoothly Deflector rod Manual operation Units are equipped with a switch to run emergency operation mode This switch is used for manual operation in case the remote controller fails to wo
10. ndicators continue flashing If one of the following code appears on the Trouble display area E0 E1 E2 E3 P0 P1 P2 P3 OF FO F1 F2 F3 The unit may stop operation or continue to run in a safety condition depending on models Waiting for about 10 minutes the fault may be recovered automatically if not disconnect the power and then connect it in again If the problem still exists disconnect the power and contact the nearest customer service center Fuse blows frequently or circuit breaker trips frequently Other ob jects or water fall into the air conditioner Terrible odors are smelled or abnormal sounds are heard Stop the air conditioner immediately disconnect the power and contact the nearest customer service center Malfunctions Cause What should be done Unit does not start Unit not cooling or heating Cooling heating Power cut Wait for power to be restored Unit may have become Unplugged Check that plug is securely in wall receptacle Fuse may have blown Replace the fuse Battery in Remote controller may The time you have set with timer is incorrect Inappropriate temperature setting Replace the battery have been exhausted Wait or cancel timer setting Set temperature correctly For detailed method please refer to Using remote control section models only Air filter is blocked Clean the air fil
11. onditioner will control room temperature automatically to the temperature point you set aroa inou e If you feel uncomfortable in the AUTO mode you can set your desired temperature Cooling SLEEP operation When you push SLEEP button on remote controller SLEEP operation during cooling heating cooling amp heating models only 7 hours timer off or AUTO operation the air conditioner will automatically increase cooling or decrease heating Set HCF 1 C 2 F per hour for the first 2 hours then hold Temperature K C 2F steadily for the next 5 hours after that it will switch off This mode saves you energy and brings you comfort hour Thou at night Heating DRYING operation The fan speed will be automatically controlled under dry operation During the dry operation if the room temperature is lower than 10 C 50 F the compressor stops operation and restarts until the room temperature is above 12 C 54 F Optimal operation e To achieve optimal performance please note the following e Adjust the air flow direction correctly so that it is not forwards people e Adjust the temperature to achieve the highest comfort level Do not adjust the unit to excessive temperature levels e Close doors and windows on COOL or HEAT modes or performance may be reduced e Use TIMER ON button on the remote controller to select a time you want to start your air conditioner e Do not put any object near air inlet or
12. ove the batteries from the remote controller The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or service provider Pre season inspection Check that the wiring is not broken off or disconnected Clean the indoor unit and filters Check that the air filter is installed Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time A Caution Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges e Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Do not wash air filter with hot water at more than 40 C 104 F Shake off moisture completely and dry it in the shade Do not expose it directly to the sun it may shrink D TROUBLESHOOTING TIPS Normal function of the air conditioner The following events may occur during normal operation 1 Protection of the air conditioner Compressor protection The compressor can t restart for 3 4 minutes after it stops Anti cold air Cooling and heating models only The unit is designed not to blow cold air on HEAT mode when the indoor heat exchanger is in one of the following three situations and the set temperatu
13. re has not been reached A When heating has just started B Defrosting C Low temperature heating e The indoor or outdoor fan stop running when defrosting Cooling and heating models only Defrosting Cooling and heating models only Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner During this condition air conditioner will stop heating operation and start defrosting automatically The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of frost built up on the outdoor unit 2 A white mist coming out from the indoor unit e Awhite mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air conditioner You may hear a low hissing sound when the compressor is running or has just stopped running It is the sound of the refrigerant flowing or coming to a stop You can also hear a low squeak sound when the compressor is running or has just stopped running This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temperature is changing e A noise ma
14. refer IMPORTANT Do not put your fingers into the panel of blower and suction side The high speed fan inside may cause danger For some models the vertical louver can be adjusted by using the remote controller Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details A CAUTION e Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode Otherwise condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings When the air conditioner is started immediately after it was stopped the horizontal louver might not move for approximately 10 seconds Open angle of the horizontal louver should not be set too small as COOLING or HEATING performance may be impaired due to too restricted air flow area e Do not move the horizontal louver manually otherwise the horizontal louver will be out of sync Please cease operating unplug power for a few seconds then restart the air conditioner Do not operate unit with horizontal louver in closed position 8 OPERATING INSTRUCTIONS How the air conditioner works AUTO operation SLEEP operation e When you set the air conditioner in AUTO mode it will 7 hours timer off automatically select cooling heating cooling heating models only or fan only operation depending on set temperature and the room temperature e The air c
15. rk or maintenance necessary NOTE The unit mustbe turned offbefore operating the manual switch If the unit is operational continue pressing the manual switch until the unit is off The manual switch is on the bottom of the unit as shown in the picture One press of the manual switch will lead to the forced AUTO operation If press the button twice within five seconds the unit AUTO COOL will operate under forced COOL operation Manual switch CAUTION This switch is used for testing purposes only You had better not choose it To restore the remote controller operation use the remote controller directly Q Ua aye Rang OPERATING INSTRUCTIONS e Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven room temperatures Adjust the horizontal louver using the remote controller e Adjust the vertical louver manually or using the remote controller depending on models To set the vertical air flow Up Down direction Perform this function while the unit is in operation Use the remote controller to adjust the air flow direction The horizontal louver can be moved at a range of 6 for each press or swing up and down automatically Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details To set the horizontal air flow direction left right Move the deflector rod manually to adjust the air flow in the direction you p
16. ter room very well while air flowing Doors or Windows are open Close the doors or windows out from the air conditioner Air inlet or outlet of indoor or outdoor unit has been blocked Clear obstructions away first then restart the unit Compressor 3 minutes protection has been activated Wait If the trouble has not been corrected please contact a local dealer or the nearest customer service center Be sure to inform them of the detailed malfunctions and unit model number Notes Do not attempt to repair the unit yourself Always consult an authorized service provider
17. ty higher than 80 Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed 9 Heating mode For cooling and heating models only The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation When the outdoor temperature falls heat drawn in by the air conditioner decreases accordingly At the same time heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 10 Auto restart function Power failure during operation will stop the unit completely For the unit without Auto restart feature when the power restores the OPERATION indicator on the indoor unit starts flashing To restart the operation push the ON OFF button on the remote controller For the unit with Auto restart feature when the power restores the unit restarts automatically with all the previous settings preserved by the memory function 11 When you are switching on or turning off the unit and suddenly there is a power cut the front panel or louver is not yet opened or closed do not attempt to press hard with force to make them fully closed When the power restores the front panel or louver will open or close automatically For specific occassions please refer to below illustrations i
18. ways contact your Use specified power cord service partner if it requires Contact the authorized installer for e Never pull the plug out by pulling on the installation of this unit cable Hold the plug firmly and pull it out of e Contact an authorized service technician the plug socket otherwise there is a risk of for repair or maintenance of this unit damaging the cable e This appliance is not intended for use by e Do not operate your air conditioner in a wet persons including children with reduced room such as a bathroom or laundry room physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the air conditioner Sooo Be sure to follow the instructions A S e Never actuate any switches with a wet hand It may cause an electric shock e Never use the device for any other purpose than the intended use Never place food precision instruments plants animals paint etc on the unit Do not expose plants or animals directly to the air flow e Never clean the air conditioner with water Never use combustible cleaning agents as these could cause a fire or deformation e Never place any burning objects close to the device if they could be directly affected by the
19. y CLEAN AIR function Optional Improving the quality of indoor air is one of the purposes of an air conditioner Thisair conditioner is equipped with ionizer With the anions generated by lonizer the air circulation of the air conditioner fills the room with refreshing natural and healthy air 8 C 46 F Heating Optional In heating operation the preset temperature of the air conditioner can be as lower as 8 C 46 F which keeps the room temperature steady at 8C 46 F in winter Follow Me function Optional The remote controlserves as aremote thermostat allowing for the precise temperature control atits location Toactivate the Follow Me feature pointthe remote control towards the unitand press the Follow Me button The remote displayis actual temperature at its location The remote control will send this signal to theair conditioner every3 minutes interval until pressthe Follow Me button again If the unitdoes not receive the Follow Me signal during any 7 minute interval the Follow Me modewill be cancelled automatically Intelligent Eye Detector With the built in infrared sensor the unit can detects existence of humans in the room If the unit keep detecting no human activity for 30 min it will automatically enters standby monitor status in order to save electricity And the unit will automatically stat and resume operation if sensing human activity again 6 OPERATING INSTRUCTIONS NOTE This manualdoes not include Re
20. y be heard due to louver restoring to its original position when power is turned on 4 Dust is blown out from the indoor unit This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit 5 A peculiar smell comes out from the indoor unit This is caused by the indoor unit giving off smells permeated from building material from furniture or smoke oO The air conditioner turns to FAN only mode from COOL or HEAT For cooling and heating models only mode When indoor temperature reaches the temperature setting on air conditioner the compressor will stop automatically and the air conditioner turns to FAN only mode The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode For cooling and heating models only to the set point e TROUBLESHOOTING TIPS The air conditioner runs Anti mildew function after turning off the unit When turning off the unit under COOL AUTO COOL FORCED COOL and DRY mode the air conditioner will run Anti mildew function for 7 10 minutes if turns off on HEAT mode the unit will Troubleshooting guide TROUBLESHOOTING TIPS OPERATION RUN indicator or other continue operating for about 30 seconds at LOW fan speed then stop the operation and turn off the unit automatically 8 Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity relative humidi