1. Step 5 Step 6 Step 7 Step 8 Connect the Network COM terminals by inserting a wire Ensure that all of the units are switched OFF DIL switch SW12 should be ON on all of the units the Alert Point expects to be connected to another unit Network COM Network OUT L O z 09 Z into unit 1 and linking this to the same terminal on unit 2 Now do the same by connecting an additional wire to the Network COM terminal on unit 2 and linking this to the same terminal on unit 3 Repeat this for subsequent units until all units are linked Insert a wire into the Network Out terminal on unit 1 and link this to the Network In terminal on unit 2 Now insert a wire into the Network Out terminal on unit 2 and link this to the Network In terminal on unit 3 Repeat this for each subsequent unit o O o O o O Z 225 x OO O OV SL 5 v23 235 2 Z Network IN Network COM Network ouT O Network IN Network COM Network ouT O Important On the final unit e g Unit 3 ensure that the Network Out terminal is linked back to the Network In terminal on unit 1 creating a loop It is not necessary to do this step for the COM wire Turn all the units ON using the master key switch TEST Alert Point 1 depress the operating element This will send the unit into alarm condition causing the activation flag to drop into vie
2. The Alert Point has seven different selectable alarm tones ranging from 95dB to 102dB along with a prefixed tamper tone This setting allows the unit to be run from an external power source DIL Switch Relay Setting DIL Switch No SW5 When part of a network this setting allows the option of sending a triggering signal via the relay to an alarm panel either e Relay is only triggered on the activated unit e Relay sends triggering signal even when another unit is activated External Sounder Strobe Trigger DIL Switch No SW6 This setting allows the option of sending a triggering signal to externally fitted sounders along with strobes beacons Internal amp External Sounder Timer Options DIL Switch No SW7 amp SW8 4 alarm durations are available and can be selected by changing the DIL switch settings These are continuous 30 seconds 3 minutes and 20 minutes If any duration period other than continuous is used the alarm will silence after the selected time has elapsed The LED will continue to flash red until the unit is reset using the reset key External Strobe Timer Options DIL Switch No SW9 amp SW10 4 strobe durations are available and can be selected by changing the DIL switch settings These are continuous 30 seconds 3 minutes and 20 minutes If any duration period other than continuous is used the strobe will cease flashing The Alert Point will still need to be reset the LED will s
3. Alertpoint Installation rev 1_2 Sep10 Installation Guide amp User Manual Contents Page Installation Guide Introduction 2 Box Contents amp Key Components 3 Specifications 3 Alert Point Installation 4 Removal of the Front Cover 6 User Manual Programmable Features 8 Other Features 9 Installing a 12 30V DC Power Supply 10 Installing External Sounders 11 Installing External Strobes Beacons 12 Installing External Detectors 13 Networking the Alert Point 14 Networking Features 16 Troubleshooting 17 PCB Terminal Diagram 18 Using an Alert Point as a Manual Call Point MCP 18 DIL switch settings Programmable Features 19 Introduction The Alert Point is an aesthetically pleasing robust and fully featured stand alone alarm system Powered with a 9V DC alkaline battery the Alert Point includes an integral sounder and resettable call point Manufactured from tough polycarbonate the Alert Point is designed for use in industrial as well as commercial or retail applications Quick and easy to install and providing protection within minutes the Alert Point is an ideal solution for establishments that have a requirement for a simple but effective alarm system They may include industrial temporary buildings warehouses portacabins churches car parks small offices and holiday parks etc Where an EN54 fire system is decommissioned on a construction site the Alert Point is ideal as a temporary system for raising an alarm in the
4. 48327 Redditch Worcestershire B98 OHU England Tel 248 673 9898 Fax 248 673 1246 Tel 44 0 1527 520999 Fax 44 0 1527 501 999 Email info sti usa com Web www sti usa com Factory settings Email info sti europe com Web www sti europe com 19 Alertpoint Installation rev 1_2 Sep10_webversion
5. is re made without having to reset the unit If both units lose their Network In or COMMON connections they will both signal a fault Note to check that the network is functioning correctly whilst avoiding having to wait 90 seconds for verification turn the unit OFF then back ON using the master key switch a fault will emit a double beep immediately on startup Key Switch Auto reset DIL Switch No SW11 ON Auto reset If an activated Alert Point is reset back to standby condition a linked Alert Point will instantly return back to its own standby condition Key Switch Manual reset DIL Switch No SW11 OFF Manual reset Please note Only if an activated Alert Point is completely reset back to standby condition using the master key switch will a linked Alert Point reset back to its own standby condition using the master key switch on a linked Alert Point will have no effect on the network once it has been turned back ON until the initially activated unit has been attended to Tamper switch activation low battery warning indication and no power source will only be signalled on the affected unit 16 Troubleshooting 9V DC battery clip not connected 12 30V DC power source installation fault Master key switch not turned ON Tamper alarm sounding Front cover fitted incorrectly Reversible mounting plate incorrectly installed The Alert Point is constantly
6. will turn red and emit a short recommended power level the unit will display a fault beep every 90 seconds emitting a periodic single beep The unit will still run safely using the 9V DC battery as a back up As soon a as power is restored the unit will automatically return to the standby Battery life The working life of the 9V DC battery under normal PE ie y taney standby condition is a minimum of 15 months it is l recommended that this battery is replaced at least every Low or No Battery If the unit is reset but the battery is at low power or not attached a fault 15 months will be indicated the LED will turn red and the unit will emit a short single beep every 90 seconds Battery back up sill we a ae Jae by a pres eae The unit automatically checks for low battery status every 16 minutes during aes a ee Ie E E a Ree this period if the battery falls into low battery condition or is disconnected in 4 eres a eee reagan E EE h the presence of an external power source the LED will turn red and emit a b ae ne d a a a short beep every 90 seconds upon detection at the end of any 16 minute cycle PAE The battery will either need replacing or reconnecting and the unit reset ee ee before it will return to a standby condition External detector checking The Alert Point is fitted with a 5V6 Zener end of line y conaitio diode enabling the unit to check for breaks in the external wiring loop of all the linked detectors Even if e
7. OFF Check all wiring connections including COMMON Check detector terminals Check all wiring connections Low battery change battery Check ext power lead connections switch OFF SW4 if no ext supply DIL switch SW11 should be ON Ensure the jumper connection is fitted correctly DIL switch SW6 should be OFF Check all wiring connections DIL switch SW6 should be OFF Check all wiring connections Cleaning should be carried out using only mild diluted detergents concentrated solutions and those including but not limited to alkalis strong acids ethers amines aromatic hydrocarbons and alcohols can cause considerable harm to this product NEED TECHNICAL SUPPORT FREEPHONE 0800 085 1678 UK TELEPHONE 44 0 1527 520 999 72 S i 2 PCB Terminal Diagram R oo ee ee o 2oOo0 9 5S5 S22 as oa oo oO ogo L Zz Z O 2 T k D D SES xk X o W Ww coe External Sounder External Sounder External Strobe Beacon External Strobe Beacon External Detector External Detector 5V6 Zener diode DIL switch j i i switc Volume jumper connection 3 pins Terminal connections External power terminals 12 30V DC Relay terminals Max 30V DC 1A External sounder terminals All external sounders need to be hard wired using 2 core cable and must have their own power supply External strobes beacons terminals All external strobes amp beacons need to be hard wired and must
8. event of an emergency Available in a variety of colours the Alert Point can be used for a wide range of applications such as fire intruder panic evacuation assist or general alarm It also incorporates a tamper switch to prevent unauthorised removal or misuse Box Contents amp Key Components Contents 4 Installation Kit 1 Reversible Mounting Plate x1 2 Chassis x1 3 Front Cover x1 Reset Key 4 Installation Kit x1 Master Key 1 4 1 Reversible Mounting Plate J 7 te IITTI Rawlplugs x4 2 Chassis Master Key Switch Cylinder 9V DC Battery Tamper Switch Operating Element 3 Front Cover Specifications Power source 9V DC battery supplied or 12 30V DC Standby current 45pA Alarm current 28mA low volume 32mA high volume Operating temperature 0 C to 49 C Sounder output at 1 metre 95dB 102dB Sounder tones 7 Tamper tone 1 Network gt 2 Alert Points spaced less than 50m apart Alert Point Installation Step 1 Install the Reversible Mounting Plate The reversible mounting plate can be installed in any orientation depending on the required conduit entry and exit points Mark the 4 fixing points as shown and install using the screws and Rawlplugs provided Pilot point x2 Fixing Points x4 Pilot point x1 Step 2 Attaching the chassis Attach by pushing the chassis over the 4 fixing clips on the mounting plate highlighted Con
9. have their own power supply Detector terminals All detectors need to be hard wired on a N O loop have their own power supply and an end of line 5V6 Zener diode fitted supplied with the unit Using the Alert Point as a Manual Call Point Using the relay terminals wire the positive loop connection into the N O terminal and the negative loop connection into the COM terminal The unit will independently sound during alarm condition as well as sending a trigger signal back the alarm panel It is recommended that all external detector wiring does not exceed 50 metres 18 DIL Switch Settings Programmable Features Important Changes made to any DIL switch settings will only take effect after the Alert Point has been reset using the master key switch Features DIL Switch Setting __ Action Inite aral pounder Alanin pau oF ofr OFF 1 800Hz 970Hz Sweep sgh one on orf on 6 2400Hz 2850Hz in 110ms Sweep Pon on on 8 Notimplemented o External power is to be supplied NB absence of power will indicate SW4 ON l External Power Provided fault LED flashing red 12 30V DC No external power is to be supplied NB absence of power will not SW4 OFF indicate a fault SW5 ON Relay is only triggered on the activated unit in a network Relay Mode SW5 OFF Unit s Relay activates in a network even if this unit was not triggered SW6 ON External Sounders Beacons are NOT triggered during a
10. in Operating element depressed alarm condition Networked The linked Alert Point is in alarm condition Tamper alarm activating Externally fitted detectors triggering Alert Point LED red amp emitting a short Networking DIL switch SW12 ON but no double beep every 90 seconds network required Connection lost between the networked Alert Points 5V6 zener diode not connected Externally fitted detector connection broken LED red amp emitting a short beep every 90 seconds 9V DC battery output power insufficient DIL switch no SW4 ON the unit is expecting external power but not receiving any Reset key not resetting Alert l n Auto reset option turned OFF Point when in alarm condition P No sound in alarm condition Volume jumper connection loose or missing External sounder DIL switch SW6 turned ON External sounders not alarming on activation External sounder connection fault External strobe beacon DIL switch SW6 turned External strobe beacons not ON flashing on activation g External sounder connection fault General Maintenance 9V DC batteries should be replaced every 15 months or sooner j ci D Voy Col ti aN Connect correctly Check installation Turn unit ON vertical position Check installation Check installation Reset using reset key Reset the networked Alert Point Check installation Check linked units are not alarming DIL switch SW12 should be
11. larm Disable External Sounders condition amp Strobes Beacons E BE SW6 OFF External Sounders Beacons are triggered during alarm condition SW7 SW8 Sounder Duration OFF OFF Sounders run continuously until manually reset Sounder Duration Timer ON OFF Sounders switch off automatically after 30 seconds OFF ON Sounders switch off automatically after 3 minutes ON ON Sounders switch off automatically after 20 minutes SW9 SW10 Strobe Beacon Duration OFF OFF Strobes Beacons run continuously until manually reset Strobe Beacon Duration Timer ON OFF Strobes Beacons switch off automatically after 30 seconds OFF ON Strobes Beacons switch off automatically after 3 minutes ON ON Strobes Beacons switch off automatically after 20 minutes SW11 ON Alert Point returns to standby condition after resetting with the reset key Auto Reset a rae Alert Point latches in alarm condition until it is manually reset using SW11 OFF the master key switch The Alert Point expects to be connected to another Alert Point SW12 ON lh otherwise a fault is indicated LED flashing constant red a Networking the Alert Point eT r SW12 OFF No fault will be indicated if an Alert Point is not connected to another Alert Point it is not looking for a connection Safety Technology International Europe Ltd Safety Technology International Inc Unit 49G Pipers Road Park Farm Industrial Estate 2306 Airport Road Waterford Michigan
12. ld be ON on both units the Alert Point expects to be connected to a second unit Network COM Network OUT zZ L O z 09 Z Step 3 Alert Point 1 Insert wires into the network terminals on the Alert Point as shown opposite Step 4 Alert Point 2 When connecting into the network terminals ensure the Network In and the Network Out wires are switched over as shown below o O Network ouT O o O Network IN Network COM Network ouT O Network IN Network COM Step 5 Turn both units ON using the master key switch Step 6 Both LEDs will now flash green approximately every 8 seconds indicating that both units are functioning correctly Step 7 TEST Alert Point 1 Depress the operating element this will send the Alert Point into full alarm condition with the activation flag dropping into view the LED flashing red and integral alarm sounding Alert Point 2 Will immediately trigger into alarm the LED will flash red and the integral alarm will sound Resetting the networked Alert Points can only be done by manually resetting the original activated unit e g Alert Point 1 from this test using the reset key This will return both units back into standby condition Step 8 The above test should now be reversed 14 Networking the Alert Point Networking 3 or more units ensure the front cover is removed Step 1 Step 2 Step 3 Step 4
13. ll remain constant if connected to an external external power supply indicating that the unit is functioning correctly power supply this indicates that the unit is functioning correctly Step 6 Test Step 6 Test When the operating element is depressed the unit will go into alarm condition the externally When the operating element is depressed the unit will go into alarm condition the externally installed sounders should now sound installed strobe s beacon s should now flash Step 7 Reset the Alert Point using the reset key all sounders should now silence Step 7 Reset the Alert Point using the reset key all strobe s beacon s should now cease flashing Please note If the Auto Reset is disabled DIL switch SW11 OFF the sounders will continue Please note If the Auto Reset is disabled DIL switch SW11 OFF the strobe s beacon s will to sound until the master Key switch is turned OFF When turned back ON the unit continue to flash until the master key switch is turned Off When turned back On the unit should be in standby condition should be in standby condition IMPORTANT Enabling Disabling external sounders will also enable disable any strobes or beacons also wired to this unit External Strobe Beacon External Sounder External Strobe Beacon External Sounder Note All external sounders must be hard wired using 2 core cable and must have their own po
14. rn the unit ON using the master key switch To adjust the volume Step 6 The LED will illuminate to a constant green indicating that eng lift off the the unit is functioning correctly jumper connector and then place over and push onto the selected pins J oo0000 Ae TUT S Alarm Condition If the unit is activated in the event of an emergency depression of Jumper connector the operating element it will immediately emit an alarm tone for the duration selected an activation flag will drop into view and the LED will flash red every 8 seconds until the unit is reset Bottom Pin Resetting Unit 1 DIL switch settings changes will only take effect when the unit has been powered back up using the master key switch 2 Silencing Alarm If the operating element has been depressed the Note Silencing the Alert Point is possible by not having the jumper fitted but reset Key is to be used to reset the unit returning it to Standby Mode no sound will be produced by the integral sounder during alarm fault or tamper o p a i Note the master key switch can be used to silence the alarm but this will turn conditions the unit OFF and the alarm will continue to sound when the unit is turned Low battery check The Alert Point monitors the output power of the 9V DC back ON battery in 16 minute cycles If the battery falls below the Power Loss In the event of any loss of power the LED
15. sult the User Manual for other programmable features Programmable Features page 8 amp DIL switch settings page 19 Attach front cover Line up each end using the channels located on the raised conduit sections see detail Push evenly until the cover locks into place via 4 raised mounting clips situated on each corner CT a a gig Alert Point Installation Step 5 Turn the unit ON Horizontal position OFF Vertical position ON Using the Master Key turn the Key Switch Cylinder to the Vertical position The LED will flash green when turned ON unit in standby condition Step 6 Test Depress the operating element Step 7 Reset the unit Simply insert the reset key into the bottom of the Alert Point A warning indicator drops into view the unit will alarm and the LED will turn red when the Alert point is activated A quick turn of the key and the Alert Point is reset returning to standby condition and is ready for use straight away Removal of the front cover Using the 2 pips on the reset key provided push firmly into each of the 4 corner clips individually releasing them whilst at the same time gently pulling the cover away from the remainder of the unit User Manual Integral Sounder Tones DIL Switch No SW1 SW3 External Power Provided 12 30V DC DIL Switch No SW4 Programmable Features Settinas PCB Layout
16. the loop and signal a fault The Zener diode must be installed at the end of line when linking detectors off the detector terminals otherwise a fault will be signalled Step 5 Turn the unit ON using the master key switch Step 6 The LED will now flash green every 8 seconds or will remain constant if connected to an external power supply indicating that the unit is functioning correctly Step 7 To test the installation of the external detectors firstly trigger one of the external detectors this should send the Alert Point into alarm condition Please note the Alert Point will only return to standby condition after the triggered detector has been reset It is recommended that the maximum wiring length from the detector terminals on the Alert Point to the final detector in the loop should not exceed more than 50 metres sil Networking the Alert Point Any alarm condition to one of the Alert Points will also trigger the linked units integral sounder and the LED flash red to indicate the fault Any external output devices that are installed to any of the Alert points will also be activated if programmed to do so Note It is recommended that wire lengths between individual units do not exceed 50m including return loop wire between last amp first units Networking only 2 units ensure the front cover is removed Step 1 Ensure that both units are switched OFF Step 2 DIL switch SW12 shou
17. till flash red until this has been done Key Switch Manual or Auto Reset DIL Switch No SW11 This allows the user greater control if misuse becomes a major factor Auto reset The Alert Point will fully reset after activation when using the reset key Manual Even if the Alert Point is reset after activation using the reset key all sounders and strobes will continue to run until the unit is reset using the master key switch Networking the Alert DIL Switch No SW12 If this switch is ON the Alert Point expects to be connected to another Alert Point otherwise a fault is indicated If the switch is OFF the Alert Point will not expect to be connected to another Alert Point Note DIL Switch settings are shown on page 19 8 Other Features Installing External 12 30V DC Power Supply Integral sounder volume The Alert Point has 2 volume settings High and Low this is Step 1 Ensure that the unit is switched OFF pee Nee External Power determined by the position of the jumper connector Step 2 l Insert the external power wires into the correct terminals configuration show below Step 3 Connect the 9V DC battery The battery must be fitted as it will become a backup if there is a power failure High Jumper between centre pin and bottom pin factory setting Low Jumper between centre pin and top pin PCB Layout Step 4 DIL switch SW4 should be ON external power required Step 5 Tu
18. w the LED to flash red and the integral alarm to sound Alert Points 2 amp 3 will also immediately trigger into alarm with LEDs flashing red and their integral alarms sounding Resetting the networked units can only be done by manually resetting the originally activated unit showing the activation flag in this case unit 1 using the reset key This will return the other units back into standby condition a15 Networking Features Loss of connection between units Any loss of connection between the networks will be indicated as a fault double beep every 90 seconds this will only be indicated on the unit expecting the input signal O o Network ouT O O O Network IN Network COM Network ouT O Network IN Network COM In the example above the Network In connection is lost on Alert Point 2 Resulting in 1 Alert Point 2 The LED will flash red and a warning double beep will sound every 90 seconds 2 Alert Point 1 cannot trigger Alert Point 2 into alarm condition the signal is lost to the Network In connection on Alert Point 2 3 Alert Point 2 can still trigger Alert Point 1 into alarm condition as the connection remains intact between the Network Out on Alert Point 2 and the Network In on Alert Point 1 4 Both units will still continue to work independently 5 Alert Point 2 will instantly return to its standby condition when the connection
19. wer supply It is recommended that external wiring does not exceed 50 metres Q CT CT CT CT CT CT Co Co Ct CT CT CT Cry Co Cr Cry CT CT Cry Cr Ci Cr Cry Ct Optional Internal Beacon An optional extra not supplied as standard for the Alert Point is the capacity to incorporate an Diagram of PCB terminal layout internal beacon this can provide for those who may be audibly impaired 11 12 Installing External Detectors With the front cover removed Step 1 Ensure that the unit is switched OFF Step 2 Disconnect the Zener diode Oo gt 5V6 Zener diode i External detector External Detector Important Please ensure all detectors have their own power source and are wired correctly in accordance with their own installation manuals 100886666E Warning Incorrectly installed external devices may cause irreversible damage to the Alert Point Step 3 Insert the external detector wires into the correct terminals tighten down the corresponding terminal screws ensuring wires are securely trapped Step 4 There is no DIL switch setting change to activate the external detectors the Alert Point is constantly monitoring for a loop connection The Zener diode creates the loop and must remain connected to the detector terminals at all times even if no detectors are being used If the Zener diode is removed the Alert Point will trace a break in
20. xternal detectors are not fitted the 5V6 Zener diode must remain connected to the Alert Point otherwise a fault will be displayed T 10 t Installing External Sounders Installing External Strobes Beacons Step 1 Ensure that the unit is switched OFF Step 2 Insert the external sounder wires into the correct terminals Step 1 Ensure that the unit is switched OFF Step 3 DIL switch SW6 should be OFF external sounders strobes to trigger during alarm Step 2 Insert the external strobe beacon wires into the correct terminals condition Step 3 DIL switch SW6 should be OFF external sounder s strobes s to trigger during alarm condition Important Please ensure all sounders have their own power source and are wired correctly in accordance with their own installation manuals Important Please ensure all external strobe s beacon s have their own power source and are wired l l l l l correctly in accordance with their own installation manuals Warning Incorrectly installed external devices may cause irreversible damage to the Alert Point Warning Incorrectly installed external devices may cause irreversible damage to the Alert Point Step4 Turn the unit ON using the master key switch Step 4 Turn the unit ON using the master key switch Step 5 The LED will now flash green every 8 seconds or will remain constant if connected to an Step 5 The LED will flash green every 8 seconds or wi