1. 5 Install the air purge valve QFSOV38 and tee fitting QFT38 as shown in the diagram AIR PURGE SYSTEM DIAGRAM SOLUTION AIR AIR OUT OUT NOZZLES 6 Mount the fog nozzle assembly FG NA N130 FG NA 26SS in the desired location using the included screws and plastic anchors Repeat as needed for multiple nozzles 7 Run tubing H38CP from the tee fitting QFT38 to the solution inlet fitting on a nozzle assembly Then run tubing from the solution outlet fitting on the original nozzle to the solution inlet fitting on the next nozzle Repeat as needed for multiple nozzles Model No FOG IT6 FG NA N130 FG NA 26SS AND RELATED ITEMS 8 Run tubing H38CP from the air outlet QF1238 on the control box to the air inlet fitting on a nozzle assembly Then run tubing from the air outlet fitting on the original nozzle to the air inlet fitting on the next nozzle Repeat as needed for multiple nozzles Note The air and solution lines must be routed to the appropriate fittings as labeled or the fog quality of the unit will be negatively impacted Make sure to insert the tubing all the way into the fittings to ensure proper connection 9 When you reach the last nozzle either plug the air and solution outlet fittings or loop the air and solution lines from the last nozzle back into the system Note Depending on your configuration plugs QFP38 additional tee
2. POLYPROPYLENE QFT38 UNION TEE 3 8in TUBE POLYPROPYLENE R38 CFDR60 3NG FILTER REG 3 8in 1034FHL 10 X 3 4 PHIL FLAT HI LO THRD SCREW 18 8 SHW3 3in LONG COATED WEIGHT SN1212 1 2in HEX STAINLESS STEEL NIPPLE SSA14 SS304 MALE FEMALE ADAPTOR 1 4 NPT X 1 4 NPT SSC38 WORM GEAR CLAMP S S 25 63 SSE12 STREET ELBOW 1 2in 316 S S SSLB 14 14GA SS BRACKETS W SLOTS SST12 1 2in FPT 304 S S TEE STR14 40 MESH SUCTION LINE STRAINER 1 4 MNPT T14B FEMALE BRASS TEE 1 4in TRDU120 120 VOLT MULTI FUNCTION TIME RELAY TRS11 11 PIN MAGNAL SOCKET TS2 TOGGLE SWITCH SPST TS2PLATE ON OFF SWITCH PLATE TSBT12 TOGGLE SWITCH BOOT TW916 1 2 INT TOOTH L W 410SS WC14BC BUTT CONNECTOR WC14FRK 14 16 INSULATED NARROW FORK TERM CONNECTOR WCB14F 14 16 1 4 FEM INSULATED CONNECTOR WCB14FY 10 12 1 4in FEMALE INSULATED CONNECTOR WMS14 14 X 1 1 4 HEX W H SMS SLOTT S S WMS14A 5 16 X 1 1 2 STRAIGHT PLASTIC ANCHOR WRIA 18 3 SJOOW 90 BLACK W 5 15P amp 7in ROJ WS 20CFM TSUNAMI WATER SEPARATOR AIR DRYER 20 CFM Page 8of8 05152014
3. RELATED ITEMS Page 7of8 05152014 User Manual Wall Mounted Fog System English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT ITEM NUMBER DESCRIPTION PB16138 GSKT NEOPRENE GASKET 0 220 INCH ROUND CORD STOCK PB16138 LATCH LATCH FOR PB16138 ACV3D 1 2 DEMA AIR SOLENOID BRASS 120v 31gpm AG100 1 5 INCH DRY MODEL 20 DUAL SCALE GAUGE B103225 10 32 X 1 4in PHIL MACH SCREW 18 8 BA38 3 8 MPT X 3 8 FPT ADAPTOR BEL14M14M BRASS ELBOW 1 4in MPT X 1 4in MPT BEL38M38M BRASS ELBOW 3 8in MPT X 3 8in MPT BN3838 BRASS HEX NIPPLE 3 8in X 3 8in BUT78GR PB OPR NO CB CC3224 LTC BLACK 1 2 NPT CC8463 1 2in NPT BLACK LOCKNUT CV38 PVC CHECK VALVE 3 8 BARBS SS SPRING EC14 2 OETIKER CLAMP 13 8 FW38 687 ID X 1 1 2 OD X 07 TK FLATWASHER 5 8 18 8 FWLG14 569 ID X 1 28 OD X 08 THICK FLAT WASHER SS 18 8 H14B H 1 4 INCH BLUE HOSE GOODYEAR HORIZON Available per ft H38B H 3 8 INCH BLUE GOODYEAR HORIZON HOSE Available per ft H38CP 3 8 IN OD POLYETHYLENE TUBING NATURAL Available per ft HB1438 1 4in MPT X 3 8in HOSE BARB PLASTIC HBB1414 BRASS 1 4 X 1 4 HOSE BARB HBF3812 HOSE BARB 3 8 X FEMALE PIPE THREAD 1 2 IN HBSS1238 STAINLESS HOSE BARB 1 2mpt X 3 8 barb HBSSEL1438 STAINLESS HOSE BARB ELBOW 1 4 INCH NPT X 3 8 HOSE BARB HHBB1418 HEX HEAD BRASS BUSH
4. fittings QFT38 and or additional tubing H38CP may be required to complete the installation 10 With the air inlet valve HV60 H in the closed position connect a compressed air line to the air inlet fitting SSE12 The air inlet fitting is 1 2 in FPT 11 Set the timer TRDU120 for the desired delay time and run time as described in the timer adjustment instructions TIMER ADJUSTMENT INSTRUCTIONS The TRDU120 is a multifunction timer 1 To set the timer 1 Thefive MODE switches A E in the bottom left corner set the timer function For fogging applications switch A and switch D should be ON and the other switches B C and E should be OFF This puts the timer in Dual Mode with the 1st Delay functioning as a delay time and the 2nd Delay functioning as a single shot run time UU UD UU U LE ao aoe Ch c pe ur RLF MADE IN US A B CD ESEC Ly io He 2 The remaining three switches in the bottom row set the time interval One switch lets you choose MIN minutes or SEC seconds The other two switches let you select a multiplier 0 1 x1 x10 or x100 which can increase or reduce the total active time 3 switches in the upper column control the active time In Dual Mode the top 5 switches control the 1st Delay delay time and the lower 5 switches control the 2nd Delay run time The active time for each
5. ft 4 6 m from nozzle Number of nozzles 1 20 nozzles per control box 1 12 nozzles per control box Tubing fitting sizes Designed for use with 3 8 in 9 5 mm outside diameter tubing between control box and nozzle s Dilution rates and flow rates given are based on chemical with viscosity of water and factory air pressure settings Area covered and run time may vary based on humidity air flow and product used Number of nozzles is dependent upon air supply see Compressed Air Requirements Model No FOG IT6 FG NA N130 FG NA 26SS AND RELATED ITEMS Page3of8 05152014 User Manual Wall Mounted Fog System English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT Installation Instructions 1 Remove all components from packaging 2 Select an area to mount the control box Note The control box should be mounted to a vertical wall We recommend mounting the control box at a height of 6 ft 1 8 m or less The chemical suction line must reach the bottom of the chemical container The bottom of the chemical container should not be positioned higher than the bottom of the control box 3 Attach the control box mounting feet to the back of the control box using the four screws provided in the parts package 4 Mount the control box to the wall using the four screws and plastic anchors provided in the parts package Note To drill holes for the plastic anchors use a 5 16 inch drill bit
6. separator WS 20CFM before the unit Model No FOG IT6 FG NA N130 FG NA 26SS AND RELATED ITEMS Page 5of8 05152014 User Manual Wall Mounted Fog System English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT CC3224 TS2 TS2PLATE TSBT12 BN3838 HHSB1238 CONTROL BOX ASSEMBLY Inside View TRDU120 P56 P56K or P56V CC8463 P56 BRKT TS2 TS2PLATE TSBT12 P56 BRKT SCREW 1 R38 FW38 Im AG100 PL G 5 BA38 WC14BC b SSE12 H14B H HV60 H Available per ft WR1A SSC38 ial CV38 D EC14 2 1 HHSB1214 AOS BA38 SSC38 BEL38M38M HBF3812 HHSB1238 QF1238 ACV3D H38B H Available per ft CC3224 SHW3 HBSS1238 HB1438 SST12 STR14 CONTROL BOX ASSEMBLY OPTIONAL COMPONENT Outside View WATER SEPARATOR Item Number WS 20CFM Model No FOG IT6 FG NA N130 FG NA 26SS AND RELATED ITEMS Page 6of8 05152014 User Manual Wall Mounted Fog System English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT NOZZLE ASSEMBLY Item Number FG NA N130 QFT38 QF1438 SSLB 14 PFN N130 E QF1438 H38CP per ft QFT38 Included in parts package NOZZLE ASSEMBLY Item Number FG NA 26SS or FOG IT6 NP y A pen Available per ft PHC1A PFN26 SS BEL14M14M QF1438 SSLB 14 T14B TW916 SSA14 QF1438 Model No FOG IT6 FG NA N130 FG NA 26SS AND
7. source and compressed air supply and open the air purge valve QFSOV38 to release any air pressure stored in the system Do not exceed an incoming air pressure of 150 psi 10 3 bar Do not exceed a fluid temperature of 100 F 37 C Only use clean and dry air Air must be filtered and free of moisture or pump life will be diminished If needed install a water separator WS 20CFM before unit Do not use an air lubricator before the unit Never use unit if it is damaged or leaking Disconnect unit from electrical power source before servicing PROTECT THE ENVIRONMENT Please dispose of packaging materials old machine components and hazardous fluids in an environmentally safe way according to local waste disposal regulations y Always remember to recycle M Specifications and parts are subject to change without notice Model No FOG IT6 FG NA N130 FG NA 26SS AND RELATED ITEMS Page 20f 8 05152014 User Manual Wall Mounted Fog System English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT REQUIREMENTS WITH FG NA N130 NOZZLES WITH FG NA 26SS NOZZLES Compressed air requirements At factory air pressure setting of 50 psi 3 4 bar 2 cfm 56 6 l min for control box plus 2 5 cfm 70 8 l min per nozzle At factory air pressure setting of 50 psi 3 4 bar 2 cfm 56 6 l min for control box plus 5 cfm 142 1 min per nozzle Maximum incoming air pressure 150 psi 10 3
8. ING 1 4in X 1 8in HHSB1214 HEX HEAD S S REDUCER BUSHING 1 2 X 1 4 HHSB1238 HEX HEAD S S REDUCER BUSHING 1 2in X 3 8 HV60 H 1 2 S S BALL VALVE W STRAIGHT HANDLE W O WELD P56 5700 PUMP WITH SANTOPRENE SEALS INCLUDES HOSE BARBS AIR FITTING AND AIR PORT P56K 5700 PUMP WITH KALREZ SEALS INCLUDES HOSE BARBS AIR FITTING AND AIR PORT P56V 5700 PUMP WITH VITON SEALS INCLUDES HOSE BARBS AIR FITTING AND AIR PORT 20756103B Polypro G57 Air Port x HB Straight w Viton o ring HB14P 1 4in BRASS HB AIR FITTING G57 P56 HB5638 HOSE BARB FOR P56 PUMP HB5638K HOSE BARB FOR P56K PUMP HB5638V HOSE BARB FOR P56V PUMP P56 BRKT PUMP BRACKET STAINLESS STEEL P56 BRKT SCREW HI LO SCREW FOR RETAINING P56 BRKT PB16138 Model No FOG IT6 FG NA N130 FG NA 26SS AND RELATED ITEMS POLYPROPYLENE CONTROL BOX WORKING DIMS 16x13x8 PUMP MOUNT PB16138 PIN STAINLESS STEEL HINGE PIN FOR CONTROL BOX PB16138 1 8 x 4 3 4 x 1 2inches PBFT PP MOUNTING FEET FOR POLYBOX PB16138 POLYPROPYLENE PFN26 SS PNEUMATIC FOG NOZZLE WITH STAINLESS STEEL TIP HIGH FLOW PFN N130 Pneumatic Fog Nozzle 1 4QMJ SUQF N130 ASSEMBLED Polypropylene and KYNAR PHC14 BLACK POLY HOSE CLAMP PL16138 CONTROL BOX LID POLYPROPYLENE 16x13x8 HINGED LOCKABLE LID PL G GREEN PILOT LIGHT MC GILL QF1238 MALE CON 3 8in TUBE X 1 2 MPT POLYPROPYLENE QF1438 MALE CON 3 8in TUBE X 1 4in MPT POLYPROPYLENE QFSOV38 SHUT OFF VALVE 3 8in TUBE
9. R The unit will begin cycling through the delay and run time intervals set on the timer beginning with the delay time 6 Atthe end of the run time the unit will shut off Observe appropriate safety precautions when reentering the area in accordance with the MSDS for your chemical product 7 Turn the power switch TS2 TS2PLATE TSBT12 OFF to prevent unwanted activation of the unit 8 With the air inlet valve HV60 H in the open position open the air purge valve QFSOV38 to clear any solution from the lines Close the air purge valve QFSOV38 after all solution has been cleared from the system Maintenance Instructions To keep your fog unit operating properly periodically perform the following maintenance procedures Note Before performing any maintenance disconnect the unit from the electrical power source and compressed air supply and open the air purge valve QFSOV38 to release any air pressure stored in the system e Inspect the pump P56 P56K P56V for wear and leaks e Inspect all hoses for leaks or excessive wear Make sure all hose clamps and push fittings are in good condition and properly secured e Check the chemical suction line and strainer for debris and clean as needed e Drain your air compressor tank on a regular basis to help extend pump life An air source with a high moisture content will accelerate pump wear Note If your air source has a high moisture content you may wish to install a water
10. USER MANUAL MODEL NUMBER FOG IT6 FG NA N130 FG NA 26SS AND RELATED ITEMS Wall Mounted Fog System English Original Instructions User Manual Wall Mounted Fog System English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT WARNING eem Control box Pump Seal Material Santoprene standard 2000004 e Kalrez K Read this manual completely and understand the Add bold option codes to item number as machine before interacting with it shown For standard options no option code is needed Read all instructions before installing or operating unit Examples Always wear appropriate personal protective equipment A PPE operating or servicing unit FOG IT6 standard unit with Santoprene pump seals Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Material Safety Data Sheet MSDS FOG IT6V unit with Viton pump seals Fogging with chemical products can be hazardous Know the hazards of your chemical products prior to FG NA 26SS use Wear appropriate personal protective equipment and follow all instructions and safety precautions in accordance with the MSDS for your chemical product If this unit is modified or serviced with parts not listed in this manual the unit may not operate correctly Before performing any maintenance on this unit disconnect the unit from the electrical power
11. bar Maximum incoming air pressure 150 psi 10 3 bar Liquid temperature range 40 100 F 4 4 37 C Electrical 120 VAC at 60 Hz 2 amps GFCI protected outlet requirements Operating voltage 120 VAC Chemical Chemical products used with this equipment must be formulated for this type of application and compatibility compatible with unit materials and pump seals For more information on chemical compatibility consult the manufacturer or MSDS for your product SPECIFICATIONS WITH FG NA N130 NOZZLES WITH FG NA 26SS NOZZLES Power type Compressed air electricity Chemical pickup type Draws from pre mixed solution Number of products unit can draw from One product Suction line length diameter 8 ft 2 4 m hose with 3 8 in 9 5 mm inside diameter Flow rate 7 9 oz min 0 23 l min 5 3 oz min 0 16 l min Pump seals Santoprene Viton or Kalrez Nozzle construction Polypropylene and kynar Celcon stainless steel EPDM and nylon Timer operation type Delay on make single shot Droplet size 15 micron at 50 psi 3 4 bar 35 micron at 50 psi 3 4 bar Coverage area 1 liter of solution will cover approximately 1000 cubic feet Coverage pattern Flat pattern with projection up to 10 ft 3 m from nozzle Pattern up to 8 ft 2 4 m wide side to side and 3 ft 0 9 m thick top to bottom with projection up to 15
12. function is equal to the total of the numbers next to any of these switches that are ON times the selected multiplier Page 4of8 05152014 User Manual Wall Mounted Fog System English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT 12 With the power switch TS2 TS2PLATE TSBT12 in the Troubleshooting Instructions OFF position plug the unit into a protected 120 VAC If air passes through the pump P56 P56K P56V without power outlet cycling the pump needs to be replaced 13 Follow all instructions from chemical manufacturer Place the chemical suction line into a container of pre mixed chemical solution e Check the chemical suction line and strainer for debris or damage Clean or replace as needed To prevent damage to the unit the strainer STR14 must always be used Operation Instructions Fogging with chemical products can be hazardous Know the hazards of your chemical products prior to use Wear appropriate personal protective equipment and follow all instructions and safety precautions in accordance with the MSDS for your chemical product 1 Prepare the area to be fogged 2 Verify the delay time and run time settings on the timer see Timer Adjustment Instructions 3 Make sure the air inlet valve HV60 H is open and the air purge valve QFSOV38 is closed 4 Turn the power switch TS2 TS2PLATE TSBT12 to the ON position 5 activate the unit push the green button BUT78G