1. LOADCTLR 0 usr pti Load xstra pci334 dfx 0 L 0 0x405e00 0x405e00 LOADCTLR 0 usr pti Load hif pci334 dfx 0 L 1 0x410000 0x0 LOADCTLR 0 usr pti Load hdlcswap mod dfx 0 L 2 0x413e00 0x0 LOADCTLR 0 usr pti Load hdlc pci334 dfx 0 L 3 0x414200 0x0 LOADCTLR 0 usr pti Load config dfx 0 L 4 0x402000 0x0 INIT L O For a Windows based system the command file looks something like this BTYPE 0 PCI334 Ma LOADCTLR 0 c pti load xstra pci334 dfx 0 L O0 0x405e00 0x405e00 LOADCTLR 0 c pti load hif pci334 dfx 0 L 1 0x410000 0x0 LOADCTLR 0 c pti load hdlcswap mod dfx 0 L 2 0x413e00 0x0 LOADCTLR 0 c pti load hdlc pci334 dfx 0 L 3 0x414200 0x0 Communications Server Update Program commupdate LOADCTLR 0 c pti load config dfx 0 L 4 0x402000 0x0 INIT LO For a second controller make a copy of the file and modify it as follows On the first line which begins with BTYPE change the 0 that follows to a 1 On each line that begins with LOADCTLR change the 0 that follows to a 1 An example is shown below BTYPE 1 PCI334 Ma LOADCTLR 1 usr pti Load xstra pci334 dfx 0 L 0 0x405e00 0x405e00 LOADCTLR 1 usr pti Load hif pci334 dfx 0 L 1 0x410000 0x0 LOADCTLR 1 usr pti Load hdlcswap mod dfx 0 L 2 0x413e00 0x0 LOADCTLR 1 usr pti Load hdlc pci334 dfx 0 L 3 0x414200 0x0 LOADCTLR 1 usr pti Load config dfx 0 L 4 0x402000 0x0 INIT L O For any additional controllers repeat this procedure but replace the zeroes with 2 3
2. MPS1000 This section applies to the NexusWare based server MPS1000 It will discuss what needs to be initially performed on the unit before it can be accessed over the LAN On the Master controller networking will need to be enabled Either a hard coded IP address or DHCP will need to be specified in the pticonfig file This must be done with the supplied console cable Refer to Chapter 2 WCP Network Configuration of the NexusWare WAN Protocol Configuration Guide 106P0150 for more details on the use of the pticonfig file MPS800 MPS600 and MPS300 This section applies to PT s LAN based MPS servers only It explains how to configure the server so that it automatically loads and begins execution whenever it is powered on or reset This configuration can be accomplished by connecting a terminal opening a window on the server s console port When a terminal is connected to the server and the server power is cycled the server PROM code provides an opportunity to specify its configuration by waiting five seconds before beginning the download process If during that time you press the terminal s space bar the PROM code prompts you for configuration information During configuration at the console you may either provide a complete configuration or indicate that the Bootstrap Protocol BOOTP is to be used to provide the complete configuration BOOTP is supported by the MPS 800 and MPS 300 600 During initialization PROM code in the serv
3. VL MPS Software and Hardware Installation Manual 205 Indigo Creek Drive Rochester NY 14626 Phone 1 585 256 0200 support pt com www pt com Document Revision History Part Number Date Explanation of Changes 106p0856 72 08 21 2007 Changes made to the commstats command Name of manual changed from Software and Hardware Installation Manual to MPS Software and Hardware Installation Manual 106p0856 73 06 13 2008 Reformatted manual 106p0856 74 03 27 2009 Removed reference to the wcpConfig utility 106p0856 75 01 14 2011 Rebranded and reformatted Added V option to System Statistics Monitor Program commstats on page 63 Copyright Notice Copyright 2011 by Performance Technologies Inc All Rights Reserved The PT logo is a registered trademark of Performance Technologies Inc All other product and brand names may be trademarks or registered trademarks of their respective owners This document is the sole property of Performance Technologies Inc Errors and Omissions Although diligent efforts are made to supply accurate technical information to the user occasionally errors and omissions occur in manuals of this type Refer to the Performance Technologies Inc Web site to obtain manual revisions or current customer information http www pt com Performance Technologies Inc reserves its right to change product specifications without notice Disclaimer This document
4. Chapter 3 Network Configuration on page 27 covers configuration of PT LAN based servers Chapter 4 QMC Configuration Guide on page 43 covers configuration of PCI37x T1 E1 J1 Communications Controllers Chapter 5 Client Utilities on page 55 covers operation of client utilities that are used to monitor and maintain PT communications software Appendix A Network Load Procedures on page 69 describes loading runtime software and server loading indicators Text Conventions This guide uses the following conventions Convention What it is Used For Monospace font Monospace font is used to represent sample code Italic font Bold font is used to represent pathnames filenames UNIX commands user input Bold font Italic font is used to represent notes that supply useful advice general information referenced documents lt gt Angle brackets are used to represent variables such as file names passwords and so on Regular font Regular font is used for the ENTER and TAB keys and the SPACEBAR on your keyboard Chapter 1 About This Guide Customer Support and Services PT offers a variety of standard and custom support packages to ensure customers have access to the critical resources that they need to protect and maximize hardware and software investments throughout the development integration and deployment phases of the product life cycle If you encou
5. Configuring a Client SS LLL DDL After editing the file either reboot the system or kill the Internet daemon the process name is inetd and restart it with the command inetd amp After editing the file enable TFTP On a Solaris 10 system this is done by converting the etc inetd conf entry into a Service Management Facility SMF service manifest and enabling the resulting service usr bin inetconv For prior Solaris releases or other UNIX systems either reboot the system or kill the Internet daemon the process name is inetd and restart it with the command inetd amp If TFTP is already enabled this step is not necessary In order for a client application to access the server during runtime operations the service name and port number must be added to the file etc services on the client The entry should look something like this mps 5555 tcp TCP normal mode A client application uses the service name in the first column to establish a connection to the server through the PT API You should always use the service name mps The port number in the second column must be followed by tcp which specifies the protocol used to access the server The port number shown above is an example and may be changed following these guidelines Use values between 5000 and 65 535 decimal and check the existing entries in the etc services file to be sure that the values you choose are not already assigned to another service The port
6. RECOVERED refers to using the recovered receive clock as the source for the transmit side This option is used when the board is slaved to the communicating equipment at the other end maxframe specifies the maximum transmit and receive frame size for all channels logical links defined in timeslot parameter below on the span timeslot specifies a channel and bit rate for each timeslot on the E1 span The E1 span is split into 32 timeslots which are time division multiplexed onto the bitstream Each timeslot is 8 bits wide and occurs at 125us intervals to yield a 64Kbit stream The first parameter on the line identifies the timeslot number 1 to 31 Some restrictions apply to the use of timeslots on E1 spans Timeslot 0 is reserved for framing the E1 span and cannot be used for data When using CAS signaling timeslot 16 is reserved for sending a specific framing word and thus cannot be used for data transfer An attempt to assign a logical channel to timeslot 16 will be rejected if CAS signaling is selected Each timeslot defined is assigned a channel number specified in the second parameter on the line The channel number 0 31 is interpreted as a logical link number by the HDLC serial device driver as follows Span 0 Channels 0 31 gt Logical Links 0 31 Span 1 Channels 0 31 gt Logical Links 32 63 Chapter 4 QMC Configuration Guide Multiple timeslots may be assigned to a given channel to produce FE1 fractional E1 cha
7. Both will allow either communications to be used What type s of PTI Servers will you be connecting to 1 CPC388 CPC358 CPC308 CPC324 Network 2 PCI384 CPC388 CPC358 CPC308 CPC324 Embedded 3 Both 6 Select the driver that will be used for embedded communication What embedded driver would you like to install 1 STREAMS driver 2 non STREAMS driver gt 2 The installation script builds the portions of the software distribution that execute on the local host system only These portions include the API library host driver if applicable and the download configuration and test utilities For the most part the installation script and the make files it executes do not modify any files or directories outside of the usr pti tree The exceptions are the API library liBbMPS a that is copied into usr lib the host driver objects that are copied into the LiS directory tree if applicable and the object modules produced by rebuilding LiS with the PT host driver included in the package if applicable Note for embedded STREAMS driver applications only If kerneld is enabled on your system the LiS package will automatically be loaded into kernel memory when you open a file descriptor to an embedded controller LiS will also be automatically unloaded from kernel memory when it has not been used for awhile If kerneld is disabled however you must manually load the streams module into kernel memory prior to opening a file descri
8. The first address is that of a Internet destination The second is the address of a gateway to be used to reach the destination There are two special cases If the destination address is 255 255 255 255 the server regards the gateway address as the default gateway If the destination address is the same as that of the server the server regards the corresponding gateway address as a subnet mask For example ROUTE 204 250 22 30 206 251 239 1294 Route to 204 250 22 30 ROUTE 255 255 255 255 206 251 239 129 Default gateway ROUTE 206 251 239 143 255 255 255 240 Subnet mask The above defines a gateway to a remote Internet destination and the Internet address of a default gateway In addition assuming the server s Internet address is 206 251 239 143 the last line in the example defines a subnet mask of 255 255 255 240 or OXFFFFFFFO SNTP The SNTP command allows configuration of two parameters used by the Simple Network Time Protocol SNTP The first parameter specifies the Internet address of the NTP server platform and the second parameter specifies the Poll Frequency Code See SNTP Configuration on page 40 for further information SNTP 206 251 239 141 5 Chapter 3 Network Configuration ELEC The ELEC command allows configuration of the electrical interface for MPS800 servers The MPS800 supports 8 RS232 and RS422 RS530 serial ports There is a two port granularity on the assignment of electrical interfaces i e por
9. maxframe specifies the maximum transmit and receive frame size for all channels logical links defined in timeslot parameter below on the span timeslot specifies a channel and bit rate for each timeslot on the T1 span In this nomenclature a timeslot is equivalent to a DSO Data Signal Level 0 The T1 span is split into 24 timeslots which are time division multiplexed onto the bitstream Each timeslot is 8 bits wide and occurs at 125us intervals to yield a 64Kbit stream The first parameter on the line identifies the timeslot number 0 to 23 Each timeslot defined is assigned a channel number specified in the second parameter on the line The channel number 0 23 is interpreted as a logical link number by the HDLC serial device driver as follows Span 0 Channels 0 23 gt Logical Links 0 23 Span 1 Channels 0 23 gt Logical Links 24 47 Multiple timeslots may be assigned to a given channel to produce FT 1 fractional T1 channels Conversely the bandwidth of a channel depends upon the number of timeslots assigned to the channel For example if eight 64Kbit timeslots are assigned to channel 3 the channel will be allocated 8 x 64Kbits 512Kbits sec or 1 3 of the T1 span Obviously both sides of the communicating equipment must agree to this mapping of timeslots and channels Chapter 4 QMC Configuration Guide SSS The next parameter on the line specifi
10. or 3 both The API will build correctly for a LAN server only if your host system includes a TCP IP package with a standard socket interface This is not a problem on most UNIX systems The choices provided for operating system type are Solaris 2 x SunOS Solaris 1 x HP UX for HP9000 Series 700 HP UX for HP9000 Series 800 DG UX IRIX V4 IRIX V5 or later DEC UX CON OO A CQ N Installation Instructions for UNIX Systems 9 QNX 10 Other If you select other the script prompts you for additional information in order to determine your operating system s UNIX compatibility The choices provided for UNIX version are 1 UNIX System V or 2 SunOS BSD This determines whether the makefile runs the ranlib utility on the API library This utility is not supported on UNIX System V If you are not sure of the correct choice for your system check your manual pages to see if ranlib is supported If so select 2 if not select 1 The choices provided for system interface definition are 1 SVR4 or 2 SVR3 This information affects the compilation of the MPSpoll API routine which uses the poll system call If your system complies with SVR4 any system file descriptor can be supplied to the po system call Under SVR3 poll is only supported for STREAMS file descriptors If you are not sure of the correct choice for your system read your manual pages for the poll system call to determine what types of fi
11. software in another location remember to substitute your base directory for usr pti when following instructions in this and other documents 1 Login as root Make sure that usr ccs bin is included in root s SUPATH environment variable definition in etc default su This is necessary to enable the operating system to find the make utility 2 Verify that the complete pathname to your compiler is specified for the CC environment variable in the file usr share lib make make rules before executing any of the following installation procedures For example if your compiler is located in opt SUNWspro bin cc CC opt SUNWspro bin cc 3 Insert the CDROM into the drive and type cd cdrom cdrom0 INSTALL Note that the CDROM device might have a different name on your system The CDROM install script will ask you to a Select your board server type from the list of board server types provided Note f you are installing software for a LAN server you will be asked to select the installation package format The choices provided are 1 pkgadd format or 2 unix tar format You must select choice 2 for non Solaris systems b Enter the installation directory 4 When you run the install script you will be asked to enter your server type s and operating system type This information is used to build the PT Application Programming Interface API The choices provided for server type are 1 LAN server 2 embedded server
12. 00 03 31 02 15 D0 ip 206 251 239 143 bf usr pti mps300 config This entry includes the Ethernet address of the server 00 03 31 02 15 D0 When the BOOTP daemon reads the server s BOOTP request it extracts the source Ethernet address from the request and checks to see if there is a matching entry in bootptab If a matching entry is found the BOOTP daemon builds a BOOTP reply message using the ip and bf fields from the bootptab entry and writes the message to the server The server reads the reply and uses TFTP to retrieve the bf file from the machine at the Internet address specified at ip Chapter 3 Network Configuration You may specify a machine to provide the configuration file that is on a network different from that of the server Consider the following bootptab entry Provide an entry for the PTI MPS 600 communications server The hd field defines the home directory The ht field defines the hardware type The ha field defines the MAC Ethernet address of the server The ip field is the host s specification of the Internet address to be assigned to the server The sa field is the Internet address of the machine to provide the configuration file The T99 field specifies the Internet address of the gateway the server is to use to access the Sa machine b The bf field is the full path name of the configuration file Since the configuration file is provided
13. ERR eee ee eb ee RERCAERE RE 40 Enter Debugger 24424065 4eai0 6 bea iraran CAR ERR ERES Heddy edie EE Ris 41 Exit arid Start DOWnIDS ey ere ker ria UR E REEYNGG rx EE a RE Vi k a Kin ea a E 41 Exit Download Then Enter PQbug 5 23 ek b pex ERR PER Kb ERR REP EROR Pg 41 Chapter 4 QMC Configuration Guide 43 sau c A Ker 43 QMC Configuration File Format 0 0 ccc e 43 Contents T1 Configuration Parameters sese ce eka ds khan eee oe SSR ee REE E REE n RUE 44 E1 Configuration Parameters x i ew RO ew Obs UR Veet kets exe eG eee heen 48 Running the QMC Configuration Utility 04 ecco bene eb RR xxn 52 Chapter 5 Client Utilities 55 NEINMIOW ec re lesen dhe a eas bebbtaeahesesogensane 55 Download Program commload 22 a ac aeaaaee 55 Descriptions cxw i dicks een taeteeuneee ene E a E aan a n a e pura EN E wae oe 55 oo E R E E E E E R E E A ee A ee 2 55 Communications Server Update Program commupdate ssassn aaaea 57 Modifying the Buffer Pool Configuration 0 0 0 cece 58 Update the Memory SIZ8 2o sob d e e wr ceE ER ER CREER ahy REG PEE RR e qe goR t 60 Modifying the MPS Server Specific Options s n anaana aaaea 62 System Statistics Monitor Program commstats 0 0c eee eee 63 SYNOPSIS pe d a es en eee eee eae LRL LUE Se 63 Descriptio EDD PTT 63 Soo Lp ETTUTUTTITETTT 63 Interpreting the System Statistics Report of a Non NexusWare Platform 64 Interpreting the Syste
14. Electrical Interface This option is only supported by the MPS 800 server Select E to program the server s line electrical interface The MPS 800 supports 8 serial ports The ports support the RS232 and RS422 RS530 interface standards The assignment of interface standards to server ports is accomplished with the command There is a two port granularity on the assignment i e ports zero and one must have the same assignment ports two and three must have the same assignment and so on When you type an i you are prompted to make the assignment for each of four pairs of server ports Type a 0 to assign RS422 RS530 to a port pair type a 1 to assign RS232 to a port pair Server s Ethernet Address The server s Ethernet address is assigned by the hardware manufacturer and cannot be modified The MPS 800 displays the assigned Ethernet address with the menu For the MPS 300 600 you can select E to display it Server s Logical Name Select N to enter the server s logical name This can be the server name or any of the aliases assigned to the server in the clients hosts databases Configuring the Server LD Server s Listen Port Numbers Select P to program the server s port numbers for normal operation First you are prompted for the server s TCP port number which must match the port number assigned in the clients services database for the TCP normal mode service See Configuring a Client on page 28 for
15. Load hdlcswap mod hdlc 0 L 2 0x413e00 0x0 0 0 LOADCTLR usr pti Load hdlc pci334 hdlc 0 L 3 0x414400 0x0 LOADCTLR usr ptiX Load config hdlc 0 L 4 0x402000 0x0 INIT L O BTYPE 0 PTI334 LOADCTLR 0 home tools pti Load xstra pci334 hdlc 0 L 0 0x405e00 0x405e00 LOADCTLR 0 home tools pti Load hif pci334 hdlc 0 L 1 0x40fe00 0x0 LOADCTLR 0 home tools pti Load hdlcswap mod hdlc 0 L 2 0x413e00 0x0 LOADCTLR 0 home tools pti Load hdlc pci334 hdlc 0 L 3 0x414400 0x0 LOADCTLR 0 home tools pti Load config hdlc 0 L 4 0x402000 0x0 INIT L O 7 Loading the Device Driver The Solaris host device driver is loaded during the installation procedure described in Step 5 above Thereafter the driver is loaded automatically whenever you reboot the system In general you never need to manually load or unload the device driver but the commands to do so are shown below To reload the driver for SBus PCI CMC or PMC communications controllers type cd usr pti drivers pt33x make Chapter 2 Software Installation Installation Instructions for Windows This section discusses the installation and setup of PT software on a Windows machine The installation process for the LAN based software differs slightly from the installation processes for the embedded based software For both installations the following apply The PT software uses the industry standard installation software InstallShield Administrative permission
16. a connection is open the request will be rejected otherwise data coming from the controller will be lost For Standby mode since the power to the PCI bus is not affected the ntmps driver will view each controller after the system has come out of Standby as it did before For Hibernate mode since the system turns off the power to the PCI bus the ntmps driver will treat each controller as if it has just been reset Instructions for Linux Systems This section describes the procedure for installing the PT software on a Linux system The PT software is capable of being used in an embedded controller environment a LAN network environment or both If you are running a LAN based application only you may skip to the next section entitled installing the PT Client Software If you intend to use the PT software for embedded applications there are certain system requirements that must be met The Linux Kernel must be Version 2 4 or higher If your kernel is prior to Version 2 4 Linux STREAMS LiS is required Please contact support pt com for assistance If your Linux Kernel Version 2 4 system already contains LiS you may wish to select the STREAMS based This may be the case if you have a previous installation of the PT product If your Linux Kernel is Version 2 6 or Version 2 4 without the LiS package installed then you will want to select the non STREAMS driver Installing the PT Client Software The PT installation procedure will
17. and should be assigned by your system administrator You can choose any logical name for the server and any number of aliases This entry should look the same in the hosts database of all clients that access the server Bootstrap Protocol The MPS 800 and MPS 300 600 servers can be configured using the Bootstrap Protocol BOOTP if the client machine is a UNIX system BOOTP is discussed in Internet Request for Comments RFC 951 and RFC1084 If BOOTP is to be used the BOOTP daemon must be running at the client when the server is booted The file etc inetd conf configures the BOOTP daemon Login as root edit this file and add the line bootps dgram udp wait root usr etc bootpd i usr etc bootptab PT does not provide a BOOTP daemon See your system administrator if your system does not include one and you wish to use BOOTP Configuring a Client You must connect a terminal or open a window to the server s console port to configure the server to use BOOTP When power is cycled or the server reset button is pushed and the server is configured for BOOTP the server broadcasts a BOOTP request message If the host BOOTP daemon is running and an entry exists in the usr etc bootptab table for the server then the BOOTP daemon sends a BOOTP reply message to the server This reply can provide the server with the following information Server s Internet address Configuration server s Internet address Configuration server s host n
18. and so on To download the second controller use commload exactly as described above but specify your new load command file name For example commload v Cmdfile copy To display the current versions the working PT environment and what is being loaded to the controller s the following commload command can be run commload i Cmdfile hdlc pci334 Note this example is using the specific command file For this case the output will be the following mps driver PTI Sbus PCIbus Driver Version 3 5 7 PTI API Version 3 3 7 Controller 0 PTI xSTRa Version 7 1 9 Controller 0 PTI HIF Driver Version 4 2 6 Controller 0 PTI HDLC QUICC Driver Version 5 1 1 Communications Server Update Program commupdate The commupdate utility allows modification of the buffer pool configuration used on the controller or server The utility modifies one of the executable files that is loaded to the controller This file is located in the PT Load directory and is called config prot H or config prot n where prot is the same filename extension used for your download command file and the suffix H or n denotes a server installation H or the controller board instance n for embedded controllers The program displays default responses in parentheses To select the default just press return To run commupdate type the following commupdate Chapter 5 Client Utilities commupdate Enter confi
19. as clear channels If this parameter is not specified the mode of operation for the channel will default to the value previously assigned to the channel if any If this is the first timeslot assigned to the channel the default is HDLC mode Warning Performance on the E1 card is directly affected by the number of timeslots configured It is highly recommended that you configure only the timeslots that you will actually be using on the span Be advised the QMC configuration utility may restrict the total number of timeslots that you may assign You may eliminate unused timeslots by simply commenting the line in the configuration file inserting a character prior to the timeslot keyword A sample E1 configuration file follows span 0 encoding HDB3 Signaling CCS crc4 on E1 Configuration Parameters alarms on clocking internal maxframe 2048 timeslot assignments for span 0 Ist parameter is timeslot number 2nd parameter channel 0 31 links 0 31 3rd parameter bitmask 64K means use all bits in timeslot 56L means mask LS bit in timeslot 56M means mask MS bit in timeslot 4th parameter operating mode hdlc default clear timeslot 1 0 64K hdlc timeslot 2 1 64K blank timeslot 3 2 64K clear timeslot 24 23 64K hdlc Span ii encoding HDB3 signaling CCS crc4 on alarms on clocking internal maxframe 2048 timeslot assignments for span 1 lst pa
20. by a machine on a different network use the vendor specific area of the BOOTP reply to specify the Internet address of a gateway T99 0Xcefbef81 251 206 239 129 ootpClient hd tftpboot V ht ethernet sha 00 03 31 02 15 90 ip 206 251 239 143 8a 204 250 22 30 N T99 0xCEFBEF81 N bf usr pti mps600 config The server s Internet address as defined in the bootptab entry is 206 251 239 143 When this address is expressed as a 32 bit number the first three bits are 110 Thus the server has a Class C Internet address and its network identifier is 206 251 239 The sa field specifies a machine with a Class C address and its network identifier is 204 250 22 The gateway Internet address specified by the 799 field is 206 251 239 129 It has the same class and network identifier as the server The sa field is the Internet address of the machine that is to provide the server with its configuration file This machine is on a different network from the server The 799 field is the Internet address of the gateway the MPS is to use to access the machine at the sa address The 799 field provides the gateway s Internet address as a 32 bit hexadecimal number You must be logged in as super user to modify bootptab Configuring the Server The server s network configuration parameters are saved in a non volatile flash PROM To program the parameters you must attach a terminal to the server s console port with an RS232 ca
21. further information Next you are prompted for the server s UDP port number Enter zero since you will not be using this service with most PT software products Finally you are prompted for the port number used by the server for broadcast connections Broadcast connections are supported only by certain special purpose server protocols You should enter zero for the broadcast port number Download Command File Pathname Select F to enter the pathname of the server s load command file This file must be present in the same location on all clients configured to load the server By default it is installed in the directory usr pti for Unix based hosts or C lpti for Windows based hosts and is named Cmdfile prot where prot is a filename extension that identifies the protocol or software configuration Check your pti directory to determine the exact name of your command file Diagnostic Configuration Since most PT software products do not make use of the server s diagnostic mode you do not need to program this option Routing Configuration Select H to enter routing information The MPS 800 and MPS 300 600 may be booted from a host on a local network or from a host on a separate network via a gateway Once booted clients may access the server from both local networks and separate networks via a gateway The routing information is stored in a table as 16 pairs of Internet addresses in decimal dot notation The first address of each pair i
22. is required to run the InstallShield setup application There are project files which are used to build the API and each of the client applications They were created with the Microsoft Visual Studio toolkit If you want to use these project files please use this toolkit The older C C compiler build projects are still supported and provided however they do not contain all of new functionality IPv6 and they will not be maintained going forward Aclient application should be linked with the PT MPS Application Programmer s Interface API It is called ibMPS lib and it has the functionality for both the embedded controller and the LAN server There is a project file which is used to build this library The library should be copied to a place where the client s projects can find and link to it By default it is copied to 6PTI96Mib Inthe client directory of each protocol there is a project file for each sample test application which are discussed in the each protocol s programmer s guide For example the PTI sbsi client directory has two workspaces defined sbsisnd dsw and sbsircv dsw When these programs are built WINNT and ANSI_C must be defined at compile time and wsoc32 lib and libMPS lib must be linked to the client application Furthermore since by default the API is built MT Safe the client application must be as well thus MT or MTd must be specified on the compiler command line See the file README THREA
23. native compiler build it again once it has completed the first build and installation procedure Make sure that opt gnu or the installation directory name you have chosen is in your PATH the second time you build it The GNU software will then rebuild the native compiler using the GNU native compiler that you have just built This is the standard GNU recommended procedure Building of the GNU tools requires anywhere from 50 to 100 Mbytes of additional free disk space for each compiler you build During the installation procedure the tools are built and copied to their run time locations The gnutools directory in pti util can then be removed freeing the majority of the disk space Source Level Debugger Installation This section describes how to build install the PT source level debuggers gdb68k or gdbppc The debugger is based on the Free Software Foundation s GDB and works in conjunction with the GNU software development tools You must complete the standard Protokit and GNU installations as described previously before installing the source level debugger As the names imply gdb68k and xgdb68k are used to debug PT Motorola 68k platforms while gdbppc and xgdbppc are used to debug PT Motorola PowerQUICC platforms The instructions below assume that you installed Protokit in the default location usr pti If you used an alternate base directory be sure to make the appropriate pathname substitutions as you type the commands The Protok
24. shown for embedded or slave controllers The mbuflist pool is used by the TCP IP stack for both sending and receiving data and for other internal memory use It reports the current number of available buffers the low watermark for available buffers min and the maximum number of buffers that are available The mcllistis a pool of buffers for use by the TCP IP stack for transferring data from the PT server to the client and reports the current number of available buffers the low watermark for available buffers min and the maximum number of buffers that are available As more sockets are opened or smaller frame sizes are configured more buffers are allocated from this pool The remaining lines of the report apply to the STREAMS message buffers that are used by protocol and serial port driver software The following is a line by line explanation of this portion of the report Chapter 5 Client Utilities dblk These lines report the usage for Data Block buffer pools The Data Block provides storage for the message data transferred over the serial ports and between the TCP IP software and the protocol software The PT software allows the definition and configuration of up to four buffer pools The size and number of buffers in each pool are configurable See Communications Server Update Program commupdate on page 57 for an explanation of how to modify the factory settings of the buffer pools Each line reports the size in bytes of each
25. them out of the Makefile xgdb68k and xgdbppc use the gdb68k and gdbppc utilities respectively and must be able to find that utility in the executable path of the current process For example if the gdb68k and xgdb68k utilities were installed in opt gnu bin then that directory must be present in your PATH environment variable Installing GDB There is no need to rebuild GDB for Sun SPARC or Intel processors running Solaris 2 6 or newer An installation script is provided to copy the executable files to an appropriate target installation directory The script prompts you for the installation pathname with a default set to opt gnu bin Install the CDROM labelled GNU Tools To run the GDB build installation script type cd cdrom cdromO0 INSTALL gdb The script will ask you Would you like to rebuild GDB programs y n Answer n to this question The script will prompt you for target type for installation directory and whether you want to use the X Window GUI During the installation procedure the tools are copied to their runtime locations Building and Installing GDB The GNU tools must be built from the source code if either of the following is true 1 your host is not a SPARC or Intel processor running Solaris 2 6 or newer or 2 you are running an older version of Solaris Run the installation script as described above the script will ask you Would you like to rebuild GDB programs y n In this case you answer y
26. DS for building the API and client applications thread safe Also make sure the client application is built the same way as the API in terms of either Debug or Release Windows LAN Based Software Installation This section discusses the issues pertinent only to a Windows software installation for LAN based PT communications servers The software installation is started by double clicking on the Setup exe application that is on the provided CDROM You will see the PT welcome screen displayed click next The software licence agreement will then be displayed read the terms and click yes to accept the agreement You will then be asked to choose a destination folder for the installation The default directory is c lpti The directory that you specify for the software to be installed will become your machine s pti directory and will have an environment variable called PTI to refer to it You must then select the hardware platform to install For a LAN installation choose an MPS server Type in the name of the MPS server that the software will connect to Next type in the IP address of that server in dot notation Both the name of the server and the IP address will then be added to the system s host table If the host table already has an entry for that server name the installation will continue without writing a new entry for that server If you don t know the name of the server to connect to just click next for the server name and IP address You c
27. TP Configuration Save The Configuration gouurgbzgucdqamrF zziLLirnuaodon oO Enter PTbug X Exit And Start Download Chapter 3 Network Configuration Client s Internet Address Select C to enter the Internet addresses of the clients that have been configured to load the server See Configuring a Client on page 28 for further information Addresses are entered in dotted decimal notation You may enter up to 100 addresses typing a carriage return after each entry and the character Q to return to the menu Insert and delete commands are available to make modification of the list easier As you edit the list the existing content of each location is displayed To change the address type the new value and press return To insert an address preceding the currently displayed entry type followed by the new address then return To delete the currently displayed entry type D and return When you reach the end of the list a marker 0 0 0 0 is displayed instead of the current value At this point you can enter an address to add to the end of the list or press return to go back to the top of the list Enter a Q to return to the main menu Server s Internet Address Select to program the server s Internet address also in dotted notation This value must match the address assigned to the server and entered in the hosts database See Configuring a Client on page 28 for further information Server s Line
28. The script will prompt you for target type for installation directory and whether you want to use the X Window GUI The script will print out status of the build as it progresses During the installation procedure the tools are built and copied to their run time locations The gnutools directory in pti util can then be removed freeing the majority of the disk space mps Configuration File mps Configuration File By default controller numbers that the Host mps ntmps for Windows driver associates with the PT controllers in the system are assigned in the order that they are made available to the driver It is the Host operating system that scans for PCI devices in the system and then calls the mps drivers attach routine for each PT controller found The order in which each PT controller is presented to the driver is not always deterministic If you wish to specifically assign controller numbers to physical PT controllers by the bus and device numbers the mps driver configuration file can be used For the Solaris operating system this file is called mps conf and a template can be found in usr kernel arv For the Linux operating system depending on the release this file is either modules conf or modprobe conf and can be found in the etc directory For Windows the registry key ntmps has two elements that help define the assignments Solaris and Linux Operating Systems In this file you can set several parameters ptix mps number c
29. WR RA REA EG E a 8 Customer Support Packages s sss o Ry RR e ERR XE RO GRECE RR RE EGRE 8 Oth r Web SUBDOM sa eds ERE ria tesda brd nur rapenean erda Der PPEPIELSRDSS 8 Return Merchandise Authorization RMA 00 0c eee eee 8 Product Warranty o 2 2she sages odtisne ode aes Pha de e ona EREE e cae ede Sea e bak ae oe 8 9 Chapter 2 Software Installation 11 r1 runc 11 Installation Instructions for UNIX Systems sssseeeele en 12 Installation Instructions for Solaris ce RETE ERR RR RR GERE E end 14 installation Instructions for WindOWwS 4s eR a a RE RR eR ko X RR CREER Rs 16 Windows LAN Based Software Installation liliis 16 Windows Embedded Based Software Installation 0000 ee eee 17 Instructions for Linux Systems 2cvisesssereedaawet PASE ERG Ewe PSE EAMES ee ES es EE eee ee 18 Installing the PT Client Software llle tees 18 Protokit Software Installation er RR cones bend RR eet peeve tee eee Ree new es 21 GNU Tools Software Installation 2 0 0 0 tee 22 Source Level Debugger Installation 0 c cee eee 23 MPS Configuration ll vesscrphpbberidbekreRrerfb ReRR bie ta OEL SNS REITS EET RIEA 25 Solaris and Linux Operating Systems enana naaraana 25 Windows Operating System 00 cc n 25 General Usage Suggestion 0 2 ce eee 26 Contents Chapter 3 Network Configuration 27 CWEIVIEW siacerubexfsweizeYosscereepbigdverw ewe
30. al factors governing the proper configuration of the buffer pools There should be one pool defined of smaller buffers typically protocols require headers to be prepended to data messages and these header buffers are usually of small size under 64 bytes Your provided software package may support multiple protocols which may have different average frame sizes An individual protocol may transfer frames of a consistent size yet require a larger or smaller control frame to be transferred occasionally Where supported client requests for statistics reporting from the server may require yet another buffer size System Statistics Monitor Program commstats In addition to the buffer pool sizes the rate at which these buffers are used must also be considered commstats provides a snapshot of the current pool usage as well as the high and low watermarks for these pools Analysis of this information can be useful in determining just how many of each buffer size should be configured to minimize the likelihood of an allocation request failing because all buffers of a given size are in use The server will attempt to allocate a buffer from the appropriate data block pool but if unable to obtain a buffer will attempt to allocate the buffer from the next larger data block pool Thus failures to obtain buffers from a given pool may not indicate any loss of data if buffers of larger size are available to handle incoming data from the serial port PT prot
31. allation procedures described in the remainder of this document and before installing the source level debugger if applicable If you are using ProtoKit with an SBus or PClbus communication controller rather than a LAN based server you must install the hardware before performing the software installation After installing the communication controller s as described in the User s Manual you received from PT boot your system using the r option so the new hardware is identified To install the Protokit software return to Installation Instructions for Solaris on page 14 Chapter 2 Software Installation GNU Tools Software Installation In order to develop software to run in the xSTRa environment you must use the software development tools supplied with Protokit These are a slightly modified version of the GNU tools from the Free Software Foundation As the tools are originally distributed they generate code for the machine type on which they are executed PT has modified the programs so that they generate code for the Motorola 68K processor or PowerQUICC processor families regardless of the machine type on which they are installed The GNU tools for Motorola 68K are used with PT servers and controllers based on that CPU The GNU tools for Motorola PowerQUICC are used for all PT platforms that use the PowerQUICC chip Therefore you will need to install the tools supplied with Protokit even if you are already using GNU The GNU s
32. ame Configuration file name Internet address of gateway to configuration server In order for your BOOTP daemon to reply to the server s BOOTP request you must edit the usr etc bootptab file to provide an entry for the server This entry includes the server s MAC Ethernet address the server s Internet address and the full path name of a server configuration file The MAC address is assigned to the server at the factory You can read it at the server 300 600 console using the E command See Configuring the Server on page 32 for further information The MPS 800 displays the MAC address when the menu is displayed The server s Internet address is assigned by you to meet your network s needs The configuration file is a text file created by you The content of this file is discussed in Configuring the Server on page 32 The format of the bootptab file is not defined in the BOOTP Requests for Comments and implementations vary The following is a typical entry in a bootptab file Provide an entry for the PTI MPS 300 communications server The hd field defines the home directory The ht field defines the hardware type The ha field defines the MAC Ethernet address of the server The ip field is the host s specification of the Internet address to b be assigned to the server The bf field is the full path name of the configuration file ootpClient hd tftpboot V sht ethernet ha
33. ame as the server s Internet address then the server interprets the corresponding gateway address as a subnet mask For example many sites choose to subnet class B addresses by using the third octet of to identify subnets and the fourth octet to identify hosts This yields a subnet mask of 255 255 255 0 If the server s Internet address is 136 19 91 35 the following entry in the routing table indicates this subnet mask I304 19 91435 ZO DOD giu The first entry is the Internet address of the server This cues the server to use the second entry in the table as the subnet mask When you select R the server prompts you to enter d to display the table x to exit from the menu item or mto modify the table If you select m the server prints the Internet address of the first entry In response to this prompt you can enter an Internet address or type q to quit the menu item or d to delete the network gateway entry pair If you enter an Internet address and press Return the server displays the corresponding gateway Internet address You may then enter an address for the gateway or d to delete the network gateway entry pair If you enter an address and press ENTER the server displays the next entry in the table User Defined Flash Prom A 1024 byte area of the flash PROM is reserved for configuring product specific parameters Most PT software products do not require any parameters to be programmed into this area of the flash PROM However three feat
34. an add that information later to SystemRoot system32 drivers etc hosts Finally the installation asks if you want to reboot your computer You must reboot your computer for the software installation to complete Remember to reboot before you try to use the PT software Installation Instructions for Windows If you are using a LAN based PT server this does not include a NexusWare server a TFTP service must be defined The TFTP server is not standard for the Windows operating system PT uses TFTPServer by SolarWinds http solarwinds net The command file Cmdfile prot that is downloaded to the server via TFTP is of type binary If you edit the file make sure line feeds do not get attached by the editor The client applications communicate with the PT LAN server through TCP IP The installation process adds the mps service to the services file SystemRoot system32 drivers etc services The PT LAN server IP address must be defined in the host table SystemRoot system32 drivers etc hosts if the server wasn t defined during installation or if the server IP changes after the installation Windows Embedded Based Software Installation This section discusses the issues pertinent only to a Windows software installation for embedded PT communications controllers The architecture platform for the Windows system must be Intel x86 or AMD Note If you have already physically installed the embedded board s on your system before installing
35. ateway process Define default gateway process ROUTE 25542951255255 206 251 239 129 Saving configuration Updating DBC bytes at 200EF110 Sending ARP Request to 206 251 239 148 SNMP Implementation on an MPS Server All configurable parameters saved on the non volatile flash PROM on MPS800 servers can be viewed or changed using SNMP A MIB Browser or SNMP Network Manager can query or set SNMP variables on the MPS Server by way of the MPS Server MIB once the Server has been Downloaded with its PT software Most parameters configurable from the MPS Server Console can be configured in this way The following lists the MPS Server MIB variable and its corresponding console entry MPSsystem MPSsysName Server s Logical Name MPScmdFile Download Command File Pathname MPSbootp Remote Configuration MPSsntpServAddr SNTP Configuration NTP Server Address MPSsntpFreq SNTP Configuration Poll Frequency Code MPSreboot Resets MPS Box not a console entry MPSip MPSipClientAddr1 Client s Internet Address First entry MPSipClientAddr2 Client s Internet Address Second entry MPSipServerAddr Server s Internet Address MPSiptcpPortNum Server s Listen Port Numbers Enter TCP Port MPSipudpPortNum Server s Listen Port Numbers Enter UD Port MPSipBroadPortNum Server s Listen Port Numbers Enter Broad cast Port MPSipNetAddr1 Routing Configuration Modify route table Network1 MPSipNetAddr2 Routing Configuration Modify route table Network2 MPS
36. axframe any up to max configured buffer size 2048 timeslot timeslot 0 23 timeslot n channel n channel 0 23 bitrate 64K bitrate 64K 56L 56M mode HDLC mode HDLC or clear E1 Configuration Parameters The keywords and valid parameter values for E1 controllers are listed below span encoding signaling specifies the physical connection on the controller There are two connectors designated as port 0 and port 1 These are synonymous with spans 0 and 1 defines the method of encoding to be used on the span HDB3 High Density Bipolar 3 Zero Maximum AMI HDB3 encoding is a zero suppression method of replacing a string of four consecutive zero bits with a binary pattern that will maintain a one s density on the line This is necessary to keep the clocking synchronized between the communicating systems All data type applications where data can be passed with 4 or more consecutive zero bits require HDB3 encoding this is the default AMI encoding specifies that logic one bits alternate polarity positive negative If for any reason the data stream is not set to HDB3 at the other end of the span AMI encoding should be selected Alternate Mark Inversion specifies the type of signaling to be used on the span which must match the type of signaling used by the connecting equipment CCS Clear Channel Signaling CAS Channel Associated Signaling E1 Configuration Parameters Note that if CCS is use
37. b k pool definitions If the frame size is large the dblk pool of the largest number of bytes must be able to accommodate its size plus any protocol overhead The number of buffers to configure for a given db k pool must also be determined by running the protocol for an extended period and then examining the max number on the report lines If that number is much smaller than the total number configured consider reducing the number of those buffers and providing more buffers to another db k pool Interpreting the System Statistics Report of a NexusWare Platform For the NexusWare controller the commstats utility is used to get a simple snapshot of the system Below is an example of the output from running commstats System Report for Server 192 139 241 146 Controller O0 Product code for kernel PTI Kernel Image 810p0574 20 The date is Wed Apr 14 07 29 47 2004 Current system kernel version 2 4 18 System has been alive 2 hrs 3 mins 27 secs Total system memory 122265600 bytes Free system memory 90238976 bytes Used system memory 32026624 bytes Running Kernel 1 Vendor Id 0x1214 Device Id 0x3580 Board serial number 12345678 Geographic Address 4 IP device information eth0 gt addr 192 139 241 146 Mask 255 255 255 0 electrical interface per port 0 RS232 1 RS232 2 RS232 3 RS232 4 RS232 5 RS232 6 RS232 7 RS232 LAN Server Reset Utility commreset The commreset utility provides a m
38. bdeiadedia eder uds e eds 27 Embedded NexusWare Controller lille 27 ilr P cr 28 MPS800 MPS600 and MPS300 sssesseesess rr 28 Configuring a Client i sore RRET A REP RA OE Pc Re RR REOR ERREUR d Bedae da gode 28 Trivial File Transfer Protocol for UNIX Systems 00 00 cee eee 28 Trivial File Transfer Protocol for Windows sesseree B 29 Bootstrap Protocol uu 2conepe rq LERNEN WO REPRE Ed cR M ER ae hae es PER RR 30 Configuring the Server ns ices ct T cv 32 Client s Internet Address 0 00 ccc tee en 34 server s Internet Address esee bei e a RR RR ER RR REGE RE be ee wea 34 Server s Line Electrical Interface 0 ce eee 34 Servers Ethernet Address scion ected Ys dae ta ER NOS twee EGRE ioe wees RE YS 34 Servers Logical Name 25oicea08 Ganmeecds ose OO DOO 1 177 711 1 TT 34 Server s Listen Port Numbers 0 00 cece een 35 Download Command File Pathname ssseeeeseeee eee 35 Diagnostic Configuration au esee testa ESCROW Rep os o Race x RR REOR CR RR CR CER wees 35 Routing Configuration xw aep eaae 35 User Defined Flash PIOS siga 840 whs tech enua atatoa iea Kiia aae eho bok EEs 36 Login PassWord ses sis teeGcaret wars bns EE RR EM HEBR or Facite we RR s 37 acisrzesreDri MITT 37 SNTP Configuration s s a acce descarta cio bdo Rr e RACIO DRCA hae RR GR RR Ea eds 40 Write New Flash Program 2 esse kev RR e
39. begins with messages regarding the BOOTP protocol message exchange and processing the configuration file Each line from the configuration file is copied to the console device as it is processed The content of this file is copied to flash PROM and then booting proceeds as shown above The following is an example of the beginning of the console output that appears when the server is configured to use the BOOTP protocol Following this output is output from the ARP request as described in the previous example Broadcast BOOTP Request xid 1 BOOTP Reply size 308 htype 1 op 2 xid 1 Bootp server 206 251 239 140 Bootp client 206 251 239 143 Gateway 0 0 0 0 Remote file usr pti mps600 config Requesting configuration file usr pti msp600 config Configuration file read complete processit process Remote configuration file for MPS diamondback process The full path name of this file is an entry process in the usr etc bootptab file process process NAME diamondbackl process CLIENT 206 251 239 148 process FILE usr pti Cmdfile x25 process process SERVER 206 251 239 143 MPS internet address process PORTS 48879 0 0 Must match etc services process DIAG n process process Enable auto reset process USER 0x00 0x00 process USER 0x01 0x00 SNMP Implementation on an MPS Server process USER 0x02 OxAO process USER 0x03 OxDO process process ROUTE 204 250 22 30 206 251 239 129 g
40. ble The terminal should be set to 9600 baud 8 bits no parity Once the terminal is attached switch the server on and press the terminal s space bar within five seconds When you do this the very first time after installing your server you will see the message Formatting uninitialized FLASH prom Configuring the Server After a slight delay a configuration menu is displayed on the terminal screen For an MPS 800 server the menu looks like this PTI Prom Version 1 0 MPS 800 Server Configuration Ethernet Address 00 11 22 33 44 55 Client s Internet Address Server s Internet Address Server s Line Electrical Interface Server s Logical Name Server s Listen Port Numbers Download Command File Pathname User Defined Flash Prom Routing Configuration Remote Configuration SNTP Configuration Write New Flash Program Save The Configuration gQzxiHUu amp ucdc u tuzpmHnuxoa oO Enter PQbug Exit And Start Download Exit Download Then Enter PQbug K X lo gt For the MPS 300 600 servers the menu looks like this Z is n 300 600 Server Configuration Client s Internet Address Server s Internet Address Server s Ethernet Address Server s Logical Name Server s Listen Port Numbers Download Command File Pathname Diagnostic Configuration User Defined Flash Prom Routing Configuration Set Login Password Remote Configuration SN
41. ccessed as specified in the client s services database If this option is not specified the service name defaults to mps For a controller installed in a backplane this parameter is not used c ctrirnum Specify the controller to use If this no controller is specified for the embedded case controller O is used If no controller is specified for the LAN case controller 15 Host board is used I IPver For LAN based NexusWare servers this option specifies the type of IP socket IPv4 or IPv6 that should be created for the connection to the NexusWare server The following values are recognized see the MPSOPEN IVP6 SOCKET xxx symbol definitions in usr pti include mpsipv6 h gt 0 There is no preference for the socket type 1 Create an IPv6 socket for the connection 2 Try to create an IPv6 socket for the connection but if it cannot be done then create an IPv4 socket instead Chapter 5 Client Utilities 3 Try to create an IPv4 socket for the connection but if it cannot be done then create an IPv6 socket instead 4 Create an IPv4 socket for the connection A default value of 0 no preference for the socket type is used when this option is omitted This option is ignored for non NexusWare LAN servers and embedded controllers N scopeID ForLAN based NexusWare servers this option specifies the IPv6 scope identifier This option is only recognized when an IPv6 socket is created for the connection to the server The defaul
42. create a directory tree on your system whose top node is named pti The default location in the file system where this directory tree is created is the usr directory i e usr pti These installation instructions and other PT documents assume that the distribution is based at usr pti If you choose to install the software in another location you must substitute the alternate directory path for usr pti when following instructions in this document and others For example if you choose to install the software in the var local directory then you must substitute var local pti for usr pti in the instructions below Installing the PT Client Software The following procedure describes how to install the PT NexusWare client software onto your Linux host Note You should be logged in as root when performing the indicated commands 1 Insert the distribution CD into the CDROM drive of your computer Change the current working directory to the appropriate device directory and run the installation script root cd mnt cdrom root INSTALL Lasi root Note The CDROM device might have a different name on your system The installation script will ask you to a Select your target operating system b Enter the installation directory e g usr c Authorize the creation of a symbolic link to the installation directory and enter the directory path for the symbolic link The default path is usr pti d Select your server type from t
43. d default the signaling channel which is in timeslot 16 can be used to pass data transparently In this mode of operation timeslot 16 may be used for normal operations and assigned to any logical channel When using CAS signaling timeslot 16 is reserved for sending a specific framing word and thus cannot be used for data transfer An attempt to assign a logical channel to timeslot 16 will be rejected if CAS signaling is selected crc enables disables a 4 bit CRC in the E1 frame The CRC is included in timeslot 0 which is used for framing the E1 A value on for this parameter enables the CRC default and a value of off disables the CRC If the connecting equipment uses CRC this feature must be enabled alarms enables disables alarms clocking specifies the type of clocking used for the transmit side of the framer The receive side clocking is always derived from the span The transmitter however can derive clocking from three different sources EXTERNAL refers to an external clock supplied at the inputs of the sync port located on the board This option is used when a reference clock is being supplied by some other piece of equipment INTERNAL refers to the on board oscillator which supplies a stratum 4 clock source to the transmitter Stratum 4 has a requirement of 30ppm parts million tolerance and is used in CPE end equipment This option is used when the board is the reference point for the clocking within the system
44. dd format proceed to Step 5 If you selected tar package format the install script asks for the complete pathname of the installation directory The script first copies the tar file to this location and then extracts it Proceed to Installation Instructions for UNIX Systems on page 12 Step 3 5 The install script asks you to Enter the complete pathname of a temporary directory to be created for the installation The install script automatically removes this directory when the installation is complete You must specify the full path of a directory that does not already exist Choose a base directory path for the installation The default location is opt Installation Instructions for Solaris Authorize the creation of a symbolic link to the installation directory and enter the directory path for the symbolic link The default path is usr pti These installation instructions and other software documentation assume that the distribution is based at the directory usr pti If you choose to install the software in another location remember to substitute your base directory for usr pti when following instructions in this and other documents Select your server type The choices provided are 1 LAN server 2 embedded server or 3 both The API will build correctly for a LAN server only if your host system includes a TCP IP package with a standard socket interface This is not a problem on most UNIX systems The install scri
45. dia contains both the host resident and controller resident portions when applicable of the software package Specifically this includes Aload command file and a set of executable files for the controller or server not applicable for a NexusWare Controller These files contain the system level code and the protocol application They are transferred to the controller or server during the download procedure Source files containing a host device driver for the communication controller not included for LAN based servers The Windows host device driver is pre compiled Source files for the host resident download configuration and test utilities Some products also include a background daemon process Source files for the PT Application Programming Interface API This is a library of subroutines to be linked with host applications that communicate with the protocol software They provide a simple read write interface to the controller s host driver or for LAN based servers to TCP IP Chapter 2 Software Installation Installation Instructions for UNIX Systems The software installation procedure creates a main directory called pti under your current directory and a number of subdirectories under pti The default location for the pti directory structure is in usr These installation instructions as well as other software documentation assume that the distribution is based at the directory usr pti If you choose to install the
46. e configuration menu before control is transferred to the boot code The following topics are covered in this appendix The Load Procedure on page 69 e MPS 3000 Family Front Panel Display on page 70 e MPS 300 600 Front Panel Display on page 71 Using the Console Port to Diagnose a Problem on page 71 SNMP Implementation on an MPS Server on page 73 The Load Procedure In the first phase of the load procedure the server uses the Address Resolution Protocol ARP to contact the client The server broadcasts an ARP request containing the client s Internet address The client responds with a packet containing its Ethernet address This exchange informs the server of the Ethernet address of the client If a client does not respond within a timeout period the server moves to the next entry in the list of clients configured to load the server Once the server has established contact with a client it uses the Trivial File Transfer Protocol TFTP to request the load command file from the client It supplies the client with the full pathname of the file which you stored in the server s flash PROM as part of the configuration procedures Using TFTP the client transfers the file to the server a block at a time If the client cannot locate the file it replies with an error packet In this case the server attempts the load from the next client in the list The load command file contains an entry for each executab
47. e file instructions on the usage of the update procedure will accompany the image Enter Debugger The Boot Prom code includes a debugger to aid in field service Invoking the debugger is not a part of the configuration process Exit and Start Download Once all the network parameters have been configured select S to program the flash PROM and save the configuration This takes a few seconds Then select X to exit from the configuration menu and transfer control to the server s TFTP load program Note If you do not save the configuration before exiting from the configuration menu the values you changed take effect when the server is booted but will be lost on the next reboot or when the server is powered off The server configuration parameters may be modified at any time by repeating the steps outlined in this section Exit Download Then Enter PQbug The MPS 800 Boot Prom code includes a debugger to aid in field service If Y is selected the server downloads the runtime image but instead of transferring to the image it transfers to the debugger instead This command is not part of the configuration process Note If you do not save the configuration before exiting from the configuration menu the values you changed take effect when the server is booted but will be lost on the next reboot or when the server is powered off The server configuration parameters may be modified at any time by repeating the steps outlined in this
48. eceive Blue Alarm T1 only known also as AIS Alarm Indication Signal set when over a 3ms window five or less zeros are received This alarm indicates that the communicating equipment has experienced either a loss of sync or loss of carrier Loss of Transmit Clock T1 only set when the TCLK pin has not transitioned for one channel time or 5 2 us This error indicates that a span configured for external clocking is not receiving a reference clock Receive Unframed All 1s E1 only known also as AIS Alarm Indication Signal set when a serious condition has been detected by the connecting equipment such as loss of sync or loss of carrier Chapter 5 emm my Client Utilities Overview This chapter contains information on the client utilities used to monitor and maintain the software running on embedded controllers and LAN servers in the PT environment The utilities are installed in the PT bin directory and are referenced as commload commupdate commstats and commreset Note Only the commstats utility applies to the NexusWare controllers PCI384 CPC38x The following topics are covered in this chapter Download Program commload on page 55 e Communications Server Update Program commupdate on page 57 System Statistics Monitor Program commstats on page 63 LAN Server Reset Utility commreset on page 67 Download Program commload Before your client application can access communicatio
49. edit the command file and modify the pathname of each executable file Below a sample file is shown with the default pathnames and then after modification to accommodate the alternate installation directory home tools Note that the details of your file may not match the examples shown here BTYPE 0 PTI334 LOADCTLR 0 usr pti Load xstra pci334 hdlc 0 L 0 0x405e00 0x405e00 LOADCTLR 0 usr pti Load hif pci334 hdlc 0 L 1 Ox40fe00 0x0 LOADCTLR 0 usr pti Load hdlcswap mod hdlc 0 L 2 0x413e00 0x0 LOADCTLR 0 usr pti Load hdlc pci334 hdlc 0 L 3 0x414400 0x0 LOADCTLR 0 usr ptiX Load config hdlc 0 L 4 0x402000 0x0 INIT L O BTYPE 0 PTI334 LOADCTLR 0 home tools pti Load xstra pci334 hdlc 0 L 0 0x405e00 0x405e00 LOADCTLR 0 home tools pti Load hdlcswap mod hdlc 0 L 2 0x413e00 0x0 LOADCTLR 0 home tools pti Load hdlc pci334 hdlc 0 L 3 0x414400 0x0 Chapter 2 Software Installation LOADCTLR 0 home tools pti Load config hdlc 0 L_4 0x402000 0x0 INIT L O Installation Instructions for Solaris When you run the install script it creates a main directory called pti and a number of subdirectories The default location for the pti directory structure is in opt with a symbolic link from the directory opt pti to usr pti These installation instructions and other software documentation assume that the software is based at the symbolic directory path usr pti Before performing the software installation you should
50. efault is HDLC mode T1 Configuration Parameters A sample T1 configuration file follows span 0 buildout 0 framing ESF encoding B8ZS alarms on clocking internal maxframe 2048 timeslot assignments for span 0 Ist parameter is timeslot number 2nd parameter channel 0 23 links 0 23 3rd parameter bitmask 64K means use all bits in timeslot 56L means mask LS bit in timeslot 56M means mask MS bit in timeslot 4th parameter operating mode hdlc default clear timeslot 0 0 64K hdlc timeslot 1 1 64K clear timeslot 2 2 64K blank timeslot 3 3 64K clear timeslot 23 23 64K hdlc Span 1 buildout 0 framing ESF encoding B8ZS alarms on clocking internal maxframe 2048 timeslot assignments for span 1 lst parameter is timeslot number 2nd parameter channel 0 23 links 24 47 3rd parameter bitmask 64K means use all bits in timeslot 56L means mask LS bit in timeslot 56M means mask MS bit in timeslot 4th parameter operating mode hdlc default clear Se ce Ge HR HR HR choc cb d N Chapter 4 QMC Configuration Guide 0 64K hdlc 1 64K clear 2 64K lt blank gt 3 64K clear 23 64K hdlc Table 4 1 T1 Configuration Details Parameter Possible values Default Value buildout 0 7 0 framing ESF or SF ESF encoding B8ZS or AMI B8ZS alarms on off on clocking internal external or recovered internal m
51. em Report is disabled by entering a zero at this offset the factory default Login Password The Login Password is not implemented on the MPS 800 If you wish to restrict access to the configuration menu select L to set up a login password You are prompted to enter a password and then prompted to retype it for verification The characters you type are not displayed on the terminal screen and the password is encoded in the flash PROM so that it is not readable You may use any combination of letters digits and special characters up to a maximum of 64 The password is terminated with a carriage return Once you have entered a password and saved it in the flash PROM the server always prompts you to supply your password when you attempt to access the configuration menu If you do not type the correct password the configuration menu is not displayed Remote Configuration The MPS 800 and MPS 300 600 servers can use the Bootstrap Protocol BOOTP to obtain the server configuration The configuration is defined in a text file you provide This text file is read by the server at boot time and is an alternative to using the console to configure the server The server uses the Trivial File Transfer Protocol TFTP to read the configuration file To use BOOTP you must provide an entry in your host s bootptab file and make sure your host s BOOTP daemon is executing when the PT server is booting If you select B the server asks you if you wish to
52. enable remote configuration using BOOTP If you respond y and follow this with X to start download or S to save the configuration and then X the server uses BOOTP to obtain its configuration When using BOOTP the server first clears the RAM memory version of the flash PROM information It then initializes the RAM copy of the flash PROM using the information in the configuration file If the configuration file is processed without error the RAM copy of the PROM information is written back to PROM You cannot use both the BOOTP protocol and the console to configure the server To use BOOTP you must request it with the B option Once you do this the setting is preserved in flash PROM and BOOTP is used until the option is disabled The Bootstrap Protocol consists of two messages a BOOTP request and a BOOTP reply The PT server writes the BOOTP request and reads the BOOTP reply that is written by the BOOTP daemon executing on a BOOTP host The reply includes the following information The server s Internet address The server s configuration full path file name Chapter 3 Network Configuration The BOOTP daemon obtains this information from the bootptab file entry you provide The PT server uses TFTP to read the configuration file to obtain its configuration Each line in the file is a configuration command The line content that follows the character is regarded as comment The commands may be entered in either upper or lower case The f
53. ent in the list The sequence can require much more time if the server must attempt to load from a number of clients before meeting with success MPS 300 600 Front Panel Display MPS 300 600 Front Panel Display The MPS 300 and MPS 600 servers have a two line LCD display on the front panel When the server is powered on the following message appears on the display PTI MPS Waiting When the boot code initiates the load procedure the Waiting message is replaced with Loading As the server obtains each executable file it displays a character beginning with A and continuing through the alphabet on the second line following the Loading message For example PTI MPS Loading C When download is complete the message changes to PTI MPS Load Complete If the server is not able to load successfully the Loading message may remain on the LCD display indefinitely or an error message may be displayed The load sequence should take 10 to 15 seconds if the server is able to contact and obtain its runtime system from the first client in the list The sequence can require much more time if the server must attempt to load from a number of clients before meeting with success Using the Console Port to Diagnose a Problem The boot code prints a number of messages on the console port as the load proceeds describing the sequence of events and any errors that may occur If your server is not able to load successfu
54. er uses TFTP Trivial File Transfer Protocol to request its runtime code from a designated client on the network You may configure the server with up to 100 clients that are able to provide the runtime code If a client does not respond to the TFTP request the server tries the next client in the list If no client responds and the Bootstrap Protocol is not configured the server returns to the top of the list and begins again retrying indefinitely If the Bootstrap Protocol is configured the PROM issues a Bootstrap Protocol request message starting the download process from the beginning Configuring a Client describes how to configure a client so it can respond to the server s TFTP requests for runtime image files Configuring the Server describes how to configure the server with information that it needs to access the client s and load the runtime system and respond to connection requests from client applications Configuring a Client Trivial File Transfer Protocol for UNIX Systems In order to load the server with a runtime system over the network the server s boot prom code and the client communicate using the TFTP protocol The file etc inetd conf configures the Internet daemon and enables the various protocols Login as root edit this file and find the entry for TFTP If the entry has a character at the left margin TFTP is not enabled Remove the character Also delete the last portion of the line that reads s tftpboot
55. es if a masking option should be implemented to provide a 56Kbit rate rather than the full 64Kbit rate for a particular timeslot The following values are allowed 64K use 64Kbit rate 56L use 56Kbit rate masking low order bit 56M use 56Kbit rate masking high order bit In certain T1 applications the requirement is to provide 56Kbit links as opposed to 64Kbit interface to end equipment that has a 56Kbit rate such as a DDS service The bit that is masked off in the 8 bit timeslot value is either the low bit normally or the high bit In either case this yields a 7 bit word which occurs every 125 us and produces the 56Kbit rate The final parameter on the line is an optional parameter that specifies if the channel assigned to the timeslot will be operating in HDLC or transparent clear channel mode hdlc HDLC channel clear Transparent clear channel blank Use last value if any for channel default is HDLC Note that this parameter applies to the channel and not the timeslot so all timeslots assigned to a channel must effectively be running the same mode i e all must be in HDLC or all transparent for a given channel However it is possible to designate some channels as HDLC channels and others as clear channels If this parameter is not specified the mode of operation for the channel will default to the value previously assigned to the channel if any If this is the first timeslot assigned to the channel the d
56. ethod to reset a LAN server unit from a client computer Note that for the reset function to succeed the server must be in an operable state The user defined flash prom may be configured to disallow this functionality if security is a concern See Network Reset on page 36 for further information There are two types of reset a hard reset default which causes the server to react as if it has been powered down and back up and a soft reset which causes the server to close all active connections in an orderly fashion Chapter 5 Client Utilities Synopsis commreset f v s server server Description The commreset program uses the PT API to communicate with the LAN server and issues a RESET hard reset or SOFTRESET soft reset ioctl command A RESET command will cause the entire server to reboot and initiate a software download A SOFTRESET command will cause all active connections to the server to be closed immediately without requiring the server to be rebooted and downloaded Regardless of the type of reset all client applications will have to reconnect once the server is back in an operational state The server name can either be specified as an option s or as a parameter to commreset Options f This parameter requests a soft reset of the server only i e all connections to the server are closed If this parameter is not specified default a hard reset of the server will be performed s server Thi
57. fault behavior of the MSP800 server 1 Blink the USER LED allows the front panel USER LED may be used for a visual display or heartbeat that signifies the unit is operation The LED will be illuminated in a 1 Hz 50 duty cycle 2 Check FEC Status allows for the software to check the status of the Fast Ethernet Controller Motorola has identified a condition where the FEC can hang when a packet gt 2047 bytes arrives The solution to this is to avoid a collision domain where such packets could be created Enabling Check FEC Status will check the FEC with each heartbeat and reset the FEC and continue if required 3 SNMP Support allows the user to disable SNMP if it is not required Communications Server Update Utility 1 Buffer Pool Configuration Update Memory Size MPS Sever Specific Save Configuration File Updates Quit O Ae W NH Enter Menu Item 1 3 Currently these options are valid for the MPS800 servers only Blink the USER LED as a heart beat signal no gt Check FEC Status no gt SNMP Support yes Communications Server Update Utility Buffer Pool Configuration Update Memory Size MPS Server Specific Save Configuration File Updates Quit OP w U He Enter Menu Item 1 gt 4 Do you really want to update Load config hdlc_mps800 H n gt y Communications Server Update Utility Buffer Pool Configuration Update Memory Size MPS Server Specific Save Configuration File Updates Qu
58. g filename below e g usr pti Load config hdlc 0 Enter config filename usr pti Load config hdlc mps800 H MEMORY SIZE 16777216 Code data reserved areas 455184 System memory 120196 Data Message blocks 14528040 Drivers Stream Head 2248 TCP memory 264448 TOTAL USED 15370116 Estimated memory available 1407100 Communications Server Update Utility 1 Buffer Pool Configuration Update Memory Size MPS Server Specific Save Configuration File Updates Quit O FF WN Enter Menu Item 1 gt Modifying the Buffer Pool Configuration With PT s protocol software a portion of memory on the controller is used for buffering data as it is transferred to and from the serial ports and for messages traveling to and from your application This memory is divided into several pools of fixed size buffers each pool having buffers of a different size The default configuration number of pools buffer sizes and number of buffers varies depending on the protocol the platform type and the amount of on board memory Depending on the packet sizes used by your protocol this default configuration may not be optimal for your application You can configure between one and four pools with any number of buffers in each pool Buffers sizes may be any multiple of 16 bytes The commupdate utility prints an error if the total memory required by your requested configuration exceeds the limit for your platform type Note The effic
59. he list of controller types provided e Select the STREAMS or non STREAMS based driver 2 The installation script prompts you for the operating system type for the product is being built This information is used to build the PT Application Programming Interface API The operating system choices for NexusWare controllers are 1 Solaris 2 x 2 Linux 3 UNIX other gt 2 You should select the option for Linux 3 Enter the installation directory at the prompt Enter the installation directory for the P057570H Installation dir opt pti Creating opt pti Copying P057570H tar gz to opt pti P057570H extracting package from tar file If the installation directory does not exist it will be created and a directory below it where the client files from the distribution media extracted 4 Authorize the creation of a logical link A symbolic link to the opt pti P057570H pti directory will be created as usr pti The PTI software will look for its files using this symbolic link You may chose a different location for the symbolic link or none at all if desired Chapter 2 Software Installation To select the default of yes press the ENTER key y y n q ENTER To select the default press the ENTER key usr pti q ENTER 5 Select the communications method with the server 1 Network will a select TCP IP socket interface 2 Embedded will select an driver for communication over the PCI bus 3
60. iency of memory usage is increased if you configure a number of small buffers e g 64 bytes each to be used for control messages as well as larger buffers to hold data messages System Statistics Monitor Program commstats on page 63 describes how it can be used to monitor buffer usage Note Also keep in mind that some protocols will dynamically request memory for buffers other than those configured by the commupdate utility Care must be taken to reserve a sufficient amount of memory for use by the protocol In order to ascertain the amount of memory that is available you should use the commstats utility to monitor memory usage under peak load conditions with the maximum number of links enabled Communications Server Update Utility 1 Buffer Pool Configuration Communications Server Update Program commupdate STE Update Memory Size MPS Server Specific Save Configuration File Updates Quit OF WN Enter Menu Item 1 gt 1 Current Configuration Class 1 Size 64 Number 14000 Class 2 Size 528 Number 8000 Class 3 Size 1040 Number 4000 Class 4 Size 2064 Number 2000 You may configure up to 4 classes of data blocks where each class contains blocks of a different size You must configure at least one class Enter number of data block classes 4 gt For each class specify the block size and the number of blocks to build Configure the class with the smallest block size first in order up
61. iguration of parameters set parameters option may only occur if there are no active host applications attached to the controller To run the gmc utility use the following command etc qmc g s f filename t stats time v z e controller c controller This parameter specifies the controller number If not specified controller defaults to 0 g This option can be used to get and display the current configuration for each span on the controller This is the default action taken by qmc if no option is selected s This option can be used to set and display the new configuration for each span on the controller In addition all statistics for the card are cleared The configuration file is specified via the f parameter Note that this option may only be executed if there are no applications using the controller f filename This option is used to specify the pathname of the configuration file for a set S operation If this option is not included the pathname defaults to etc t1config in the UNIX environment or t1 config for Windows NT Presence of this option implies a set operation Running the QMC Configuration Utility t stats time This option allows periodic monitoring of T1 E1 and HDLC statistics The monitoring interval is specified in seconds Once qmc has executed all other requests it enters into an indefinite loop requesting and displaying statistics at the specified interval y Th
62. ing the Server on page 32 Embedded NexusWare Controller The NexusWare CompactPCI controllers can be configured as TCP IP servers To do so it is critical that the configuration of their jumpers or switches match that of the chassis to be used Typically this would imply that the controller be configured for Standalone mode In Standalone mode the controller is responsible for the generation of the clocking that would otherwise be supplied from the PCI bus Table 3 1 Busless Configurations for NexusWare Controllers contains only the switches that are required when the PCI bus is not being used For full details on the jumpers and switches associated with your specific controller refer to your hardware User s Guide from PT Table 3 1 Busless Configurations for NexusWare Controllers CPC Card Switch Description CPC358 K38 2 3 IN Install on busless systems Connects on board clock to Tundra PowerSpan K43 1 2 OUT Allows for alternate power on control signal source K46 1 2 IN No external controller is necessary power always on CPC388 K44 3 4 IN No external controller is necessary power always on K46 1 2 IN Install on busless systems Connects on board clock to Tundra PowerSpan K47 1 2 OUT Allow 3V signal to be put on PCI Bus pins if no PCI Bus is present K48 1 2 OUT Removed for busless systems CPC308 SW5 2 ON STANDALONE provide internal PCI clock CPC324 Chapter 3 Network Configuration
63. install your communication controller hardware Then boot your system using the r option so the new hardware is identified 1 To install the software distribution first login as root 2 Make sure that usr ccs bin is included in root s SUPATH environment variable definition in etc default su This is necessary to enable the operating system to find the make utility Verify that the complete pathname to your compiler is specified for the CC environment variable in the file usr share lib make make rules before executing any of the following installation procedures For example if your compiler is located in opt SUNWspro bin cc CC opt SUNWspro bin cc e Insert the media into the drive and inform the volume manager that you have done so A Change directory to the appropriate device and run the install script Enter the following commands cd cdrom cdrom0 INSTALL The CDROM install script will ask you to a Select your board server type from the list of board server types provided Note f you are installing software for a LAN server you will be asked to select the installation package format The choices provided are 1 pkgadd format or 2 unix tar format It is recommended to select choice 1 if you are installing our software products on a Solaris system The second option unix tar format is for installing products on the UNIX systems that do not support the Solaris pkgadd utility If you selected pkga
64. ipNetAddr3 Routing Configuration Modify route table Network3 MPSipGateAdadr1 Routing Configuration Modify route table Gateway1 MPSipGateAddr2 Routing Configuration Modify route table Gateway2 MPSipGateAddr3 Routing Configuration Modify route table Gateway3
65. is option causes qmc to display detailed information as it performs a reconfiguration z This option causes qmc to zero all T1 E1 statistics Options may be specified independently or in combination Some examples follow 5 Request current configuration on controller 1 etc qmc c 1 OR etc qmc g c 1 6 Set new configuration on controller 0 using file myconfig etc qmc f myconfig OR etc qmc s f myconfig 7 Clear all statistics on controller 0 and monitor every 3 seconds etc qmc z t 3 Statistics displayed by qmc include the status of each span T1 E1 network statistics and HDLC statistics Stats for Tl card controller 1 T1 Span 0 Status Network is UP T1 Span 1 Status Network is UP Span 0 n w c np Severely errored seconds Errored seconds Line code bipolar violations CRC errors Out of frame errors Messages received Messages transmitted Receive overruns Receive frames too big Receive CRC errors Receive aborts 0 0 1 3 0 0 177 386 0 0 0 O OGOGO UGO GO U H O The following is a list of possible statuses for the span Network is UP the span is synchronized and ready for data transfer operations Receive Carrier Loss set when 192 consecutive zeros T1 or 255 consecutive zeros E1 have been detected on the span Receive Loss of Sync set when the device is not synchronized to the receive T1 E1 stream Chapter 4 QMC Configuration Guide R
66. it OP WNE Enter Menu Item 1 gt 0 System Statistics Monitor Program commstats System Statistics Monitor Program commstats The commstats utility provides remote access to the buffer and memory usage statistics on an embedded controller or LAN server This utility may be useful when desiring to tune factory configured buffer pools for better performance Synopsis commstats s server S service e ctrirnum I IPver N scopeID d i V Description The commstats program uses the PT API to communicate with the controller whether embedded or over a Local Area Network For LAN servers commstats allows any user on the same network the ability to query statistics information for any controller on a PT server For embedded controllers commstats allows the user the ability to monitor the statistics of any communications controller Options s server This parameter identifies the target server For a LAN based server this is the logical host name as specified in the client s hosts database or an IP address specified in either IPv4 dotted decimal or IPv6 colon hex notation For a controller installed in a backplane server is the pathname of the driver s cloneable special file If this option is not specified the server name defaults to dev ucsclone for UNIX based systems and PTIXpqcc for Windows based systems S service ForLAN based servers this parameter identifies the service name to be a
67. it CDROM labeled GNU Tools contains the GDB distribution The source for GDB is contained in the subdirectory gnutools gab 4 17 Source for an X windows graphical user interface GUI for GDB is also included and is located in the directory gnutools xxgab 1 06 The distribution includes complete source for GDB If you purchased Protokit for Solaris 2 X the distribution also includes pre built executables for Sun SPARC or Intel processors using Solaris 2 6 or newer There are two procedures outlined below If you are running on a Sun SPARC or Intel processor that has Solaris 2 6 or newer use Installing GDB on page 24 If not use the alternate procedure Building and Installing GDB on page 24 To build the X windows GUI programs xgdb68k and xgdbppc you must have X11 Release 4 or later installed on your system You must also set your path variable to include the directory where your X11 binaries are located in order to use the imake utility that is invoked by the script Chapter 2 Software Installation If you are using the GNU tools rather than the standard SunPro tools to build executables for your host system edit the file makefile in pti util gnutools xxgdb 1 06 before you begin the build procedure Modify the line that reads CC gcc v removing the symbol at the start of the line However the imake program may have produced a Makefile that contains switches not supported by the GNU compiler If so you will have to manually pull
68. le descriptors are supported If any system file descriptor can be used select 1 if only STREAMS file descriptors can be used select 2 The installation script builds the portions of the software distribution that execute on the local system with the exception of the host driver if included These include the API library and the download configuration and test utilities Except for the API archive ibMPS a which is copied to usr lib the installation script and the Makefiles it executes do not modify any files or directories outside usr pti 5 Skip this step if either you installed the software in the default usr directory or you are installing for a NexusWare CPC388 product The load command file in the main pti directory is named Cmdfile prot where prot is a filename extension identifying a specific software product or configuration The load command file contains the names of the executable files that are loaded to the communication controller or server This file is used during the load procedure and must contain the correct full pathname of each file If you did not install the software in the default directory the pathnames in this file are incorrect The easiest solution is to create a symbolic link to the usr pti directory In the following example a link is created from the alternate installation directory home tools 1n s home tools pti usr pti If for some reason this solution is not acceptable you must
69. le file to be loaded and includes the full pathname of each file In the third and final phase of the load procedure the server uses this information to request each required executable file from the client These files are also transferred using TFTP The last entry in the load command file provides startup information which the server uses to transfer control to the runtime system If an error occurs generally due to a missing executable file or a corrupted load command file the server aborts the load procedure It then locates the next client in the list and broadcasts another ARP message to restart the load procedure If the server cannot successfully complete the load from any of the configured clients it returns to the top of the list and retries the procedure with each client in turn This process continues until the server is downloaded successfully from one of the configured clients MPS 3000 Family Front Panel Display For a server in the MPS 3000 family the RUN LED on the server s front panel is used to indicate status When the boot code initiates the load procedure the LED begins to flash When download is complete the LED no longer flashes and should remain illuminated until the server is reset or powered off If the server is not able to load successfully the RUN LED continues to flash indefinitely The load sequence should take 10 to 15 seconds if the server is able to contact and obtain its runtime system from the first cli
70. lly the RUN LED continues to flash indefinitely or the LCD display indicates an error condition you should attach a terminal to the console port as described in Configuring the Server on page 32 to observe the output In the example below the server s boot code attempts to load from three clients The first does not respond at all the second responds but is not able to supply one of the required files and the third completes the load successfully Sending ARP Request To 100 0 0 33 No ARP Reply Sending ARP Request To 100 0 0 8 Received ARP Reply Requesting Boot File usr pti Load Cmdfile x25 File Obtained Requesting File usr pti Load UC tcp ucmps x25 H File Obtained Requesting File usr pti Load wan ucmps x25 H File Not Found Sending ARP Request To 100 0 0 2 Received ARP Reply Requesting Boot File usr pti Load Cmdfile x25 File Obtained Requesting File usr pti Load UC tcp ucmps x25 H File Obtained Requesting File usr pti Load wan ucmps x25 H File Obtained Requesting File usr pti Load hdlc ucmps x25 H File Obtained Requesting File usr pti Load lapb mod x25 H File Obtained Requesting File usr pti Load plp mod x25 H File Obtained Requesting File usr pti Load reset mod x25 H File Obtained Requesting File usr pti Load xSTRa ucmps x25 H File Obtained Requesting File usr pti Load config x25 H File Obtained Initializing Module L_6 Init L_6 at 200BBC40 When BOOTP is configured on the console log
71. m Statistics Report of a NexusWare Platform 67 LAN Server Reset Utility commreset 000 eh 67 SYNOPSIS P TTC 68 Bis eqjeifol NTC deak aaa aa o a E TITEL T1010 1 05 5 000 7270100 COTES 68 S I CC T DEEERRUTTUMTPMUTIITM 68 Appendix A Network Load Procedures 69 9 y ecc TC a a a a a a a a aa e e 69 The Load PIOCSOUIS occa an are peeti ers RE EY uae E NR ER RO ee Ee cds harte ko SR S 69 MPS 3000 Family Front Panel Display liielseelseee I 70 MPS 300 600 Front Panel Display llesllesseleereee eh 71 Using the Console Port to Diagnose a Problem 0 00 cece eee eee 71 SNMP Implementation on an MPS Server 000 c cece 73 UIPSSUSIBITI ose T TES SER as Usd ede te eet pedi p ird Edd Sew eh Deeds dud 73 Contents Chapter 1 SSS About This Guide SSS Overview This document describes software and hardware installation procedures for PT WAN access products PT software runs on intelligent serial communication controllers installed in either a UNIX or Windows host system or on PT LAN based communication servers Some sections of this installation guide apply only to certain host controller or server types and are not applicable to others The contents of each chapter in this manual are described below Chapter 2 Software Installation on page 11 covers basic software installation procedures for UNIX Solaris Windows and Linux based systems
72. n protocol software you must load the software to the server or communication controller For a LAN based server this is done automatically when the server is powered on or reset The network load procedure is described in Appendix A Network Load Procedures on page 69 For an embedded communication controller download requires the use of the commload utility Description For embedded controllers the commload program accesses the PT STREAMS driver to download one or more controllers according to instructions provided in the command file Cmdfile xxx the actual name of the file will vary depending on the protocol software If the full pathname for Cmdfile xxx is not specified commload expects to find the file in the current directory Options s server This parameter identifies the target server For a LAN based server this is the logical host name as specified in the client s hosts database For a controller installed in a backplane server is the pathname of the driver s cloneable special file If this option is not specified the server name defaults to dev ucsclone for UNIX and PT Xpqcc for Windows based systems Chapter 5 Client Utilities SSS SSS SSS S service For LAN based servers this parameter identifies the service name to be accessed as specified in the client s services database If this option is not specified the service name defaults to mps For a controller installed in a backplane this parameter is not u
73. nnels Conversely the bandwidth of a channel depends upon the number of timeslots assigned to the channel For example if eight 64Kbit timeslots are assigned to channel 3 that channel will enjoy 8 x 64 512Kbits sec or 1 4 of the E1 span Obviously both sides of the communicating equipment must agree to this mapping of timeslots and channels The next parameter on the line specifies if a masking option should be implemented to provide a 56Kbit rate rather than the full 64Kbit rate for a particular timeslot The following values are allowed 64K use 64Kbit rate 56L use 56Kbit rate masking low order bit 56M use 56Kbit rate masking high order bit The bit that is masked off in the 8 bit timeslot value is either the low bit normally or the high bit In either case this yields a 7 bit word which occurs every 125 us and produces the 56Kbit rate The final parameter on the line is an optional parameter that specifies if the channel assigned to the timeslot will be operating in HDLC or transparent clear channel mode hdic HDLC channel clear Transparent clear channel lt blank gt Use last value if any for channel default is HDLC Note that this parameter applies to the channel and not the timeslot so all timeslots assigned to a channel must effectively be running the same mode i e all must be in HDLC or all transparent for a given channel However it is possible to designate some channels as HDLC channels and others
74. nstallation instructions for UNIX and Windows host systems Choose the appropriate section for your host system and follow the instructions in that section Before proceeding with the software installation you should install your hardware For installation of a LAN based server or a NexusWare controller that will use TCP IP sockets to communicate with its host processor refer to Network Configuration on page 27 For installation of embedded communications controllers that will communicate over the PCI bus with its host processor refer to the hardware User s Guide your received from PT The following topics are covered in this chapter Installation Instructions for UNIX Systems on page 12 Installation Instructions for Solaris on page 14 Installation Instructions for Windows on page 16 Instructions for Linux Systems on page 18 Installing the PT Client Software on page 18 Protokit Software Installation on page 21 mps Configuration File on page 25 If your Host system has Solaris Linux or Windows as the operating system and the embedded mps driver will be used for controller access over the PCI or cPCI bus be sure to read mps Configuration File on page 25 regarding the mps configuration file If you are installing the Protokit software and the GNU tools refer to the instructions listed under Protokit Software Installation on page 21 The software is shipped on CDROM The me
75. nter difficulty in using this PT product you may contact our support personnel by 1 EMAIL Preferred Method Email us at the addresses listed below or use our online email support form Outline your problem in detail Please include your return email address and a telephone number 2 TELEPHONE Contact us via telephone at the number listed below and request Technical Support Our offices are open Monday to Friday 8 00 a m to 8 00 p m Eastern Time PT Support Contact Information Embedded Systems and Software SS7 Systems Includes Platforms Blades and Servers Includes SEGway Email support 2pt com ss7support pt com 1 585 256 0248 1 585 256 0248 Phone Monday to Friday 8 a m to 8 p m Monday to Friday 8 a m to 8 p m Eastern Time Eastern Time If you are located outside North America we encourage you to contact the local PT distributor or agent for support Many of our distributors or agents maintain technical support staffs Customer Support Packages Our configurable development and integration support packages help customers maximize engineering results and achieve time to market goals To find out more about our Customer Support packages visit http www pt com page support Other Web Support Support for existing products including manuals release notes and drivers can be found on specific product pages at http www pt com Use the product search to locate the information y
76. number assigned must be the same on all clients that access the server The final column contains an optional comment designated by the character To establish a connection to the server the API also requires the server s logical host name and Internet address to be added to the hosts database An entry in this file looks something like the following example 100 0 0 8 indiana indy hoosier The first column contains the Internet address in the standard dotted format In this example the host name is indiana with indy and hoosier as aliases or nicknames which can be substituted for the host name The Internet address you use must be consistent with your network and should be assigned by your system administrator You can choose any logical name for the server and any number of aliases This entry should look the same in the hosts database of all clients that access the server Trivial File Transfer Protocol for Windows Having a PT server boot over the LAN from a Windows machine can only be performed when the Windows machine has a TFTP server running The client TFTP server software is not standard for the Windows operating system Therefore you will need to obtain and install this TFTP software in order to download the PT server PT uses TFTPServer by Solar Winds http solarwinds net Chapter 3 Network Configuration T In order for a client application to access the PT server during runtime operations the service name and port n
77. ocols are designed to accept incoming data as long as sufficient memory is available for message storage and where supported use protocol mechanisms to notify the remote station to refrain from sending more data if memory is unavailable to store data If the client application does not issue read requests to the server in a timely manner buffer pool exhaustion can also occur Thus commstats can be used as a troubleshooting tool during client application development An example of the output from commstats follows with an explanation of how to analyze it System Report for Server mps800 Controller 0 dblk 1 64 current 4 max 5 tot 15000 fail 0 dblk 2 272 current O0 max 0 tot 5000 fail 0 dblk 3 528 current 1 max I EOR 5000 fail 0 dblk 4 1040 current O0 max 0 tot 5000 fail 0 total dblks current 5 max 53 tot 30000 fail 0 total mblks current 5 max 53 tot 30000 fail 0 memory avail current 4436688 min 4436688 electrical interface per port 0 RS232 1 RS232 2 RS232 3 RS232 4 RS232 5 RS232 6 RS232 7 RS232 The first line includes the host name given to the server mps800 For an embedded controller the line will indicate the name of the device normally dev ucsclone and the controller number The next two lines apply to the buffer pools used by the TCP IP stack on a PT LAN based server e g an MPS300 600 and MPS800 These lines do not apply to and therefore are not
78. oftware is on the second CDROM labeled GNU Tools The distribution includes complete source for all the utilities as well as pre built executables for Sun SPARC or Intel processors using Solaris 2 6 or newer There are two procedures outlined below If you are running on a Sun SPARC or Intel processor that has Solaris 2 6 or newer use Installing the Tools on page 22 If not use the alternate procedure Building and Installing the Tools on page 23 Your host must have a C compiler available to rebuild the tools Before running the build installation script you must add two directories to your PATH environment variable By default these are opt gnu68k pti bin and opt gnu68k pti lib for the Motorola 68K tools and opt gnuppc pti bin and opt gnuppc pti lib for the Motorola PowerQUICC tools Once the tools have been built and or installed all users of the tools must also add these directories to their PATH If you elect to build the native compiler a default installation directory of opt gnu is used which must then also be added to your PATH Installing the Tools There is no need to rebuild the tools for Sun SPARC or Intel processors running Solaris 2 6 or newer An installation script is provided to copy the executable files for the utilities to an appropriate target installation directory The script prompts you for the installation pathname with a default based on the GNU target type For instance if you are installing the GNU tools f
79. ollowing are the valid commands CLIENT SERVER NAME PORTS FILE DIAG USER ROUTE SNTP and ELEC These commands are used in the same way as when the server is being configured at the console The discussion above provides details on how the server uses the configuration information The following describes the format of the commands CLIENT The CLIENT command is followed by one or more client Internet addresses separated by spaces or tabs The format of the addresses is decimal dot notation For example CLIENT 206 251 239 148 206 251 239 149 SERVER The SERVER command defines the Internet address of the MPS 800 and MPS 300 600 server If a SERVER command is omitted from the configuration file the server uses the Internet address provided in the BOOTP reply Only one address is allowed with the SERVER command For example SERVER 206 251 239 143 PTI MPS 600 NAME The NAME command identifies the server s name For example NAME diamond PORTS The PORTS command has up to three entries the server s tcp port udp port and udp broadcast port The ports are provided as decimal numbers For example PORTS 488790 0 The above entry indicates that the server is to use the TCP protocol and to listen at well known port 48879 In addition the entry indicates that the UDP protocol is not to be used These are typical assignments The port assignments must match those in the etc services file FILE The FILE command defines
80. ontrollers will specify the number of PT controllers in the system or zero if the configuration file should not be used and the default controller assignments will be performed The ptix mps controller entries is a list of controller bus device numbers for each PT controller assignment ptix mps dev path entries is specific to Solaris and is used for identifying controllers across multiple PCI domains Note If a default installation of the PTI software was done on the system the template mps conf file will be put in the usr kernel arv directory The Linux configuration file mps_linux conf can be modified and appended into the pre existing system file etc modules conf or etc modprobe conf depending on your release For the Linux case there must be no spaces or tabs between the comma delimited entries in ptix mps controller entries If the Host mps driver detects an error when parsing the file it will report the error to the messages or log file and reject loading Windows Operating System The ability to specifically assign controller numbers in the Windows Operating System is available for versions 2000 and above Specifically this support is not available in Windows NT The registry key for the ntmps driver is HKEY_LOCAL_MACHINE SYSTEM CurrentControlSet Servicestntmps This key has two elements which need to be modified NumberOfControllers will specify the number of PT controllers in the system or zero if the manual config
81. or support of Motorola 68K platforms the default directory is opt gnu68k pti If you choose another pathname the install script creates a symbolic link from opt gnu68k pti to your path Install the CDROM labelled GNU Tools To run the GNU build installation script type cd cdrom cdrom0 INSTALL gcc The script will ask you Would you like to rebuild GNU tools y n Answer n to this question Installation of the GNU tools requires between 10 to 15 Mbytes of free disk space depending on which target you are installing The script will ask you for the target type Motorola 68k PowerQUICC or native compiler and for the installation directory pathnames During the installation procedure the tools are copied to their runtime locations Protokit Software Installation Building and Installing the Tools The GNU tools must be built from the source code if one of the following apply 1 your host is not a SPARC or Intel processor running Solaris 2 6 or newer or 2 you are running an older version of Solaris Run the installation script as described above the script will ask you Would you like to rebuild GNU tools y n In this case you answer y The script will ask you for the target type Motorola 68k PowerQUuICC or native compiler and for the installation directory pathnames The script will print out status of the build as it progresses this is a lengthy operation on most computers Note If you have elected to build the
82. ou need Return Merchandise Authorization RMA To submit a return merchandise authorization RMA request complete the online RMA form available at http pt com assets lib files rma request form doc and follow the instructions on the form You will be notified with an RMA number once your return request is approved Shipping information for returning the unit to PT will be provided once the RMA is issued Product Warranty Product Warranty Performance Technologies Incorporated warrants that its products sold hereunder will at the time of shipment be free from defects in material and workmanship and will conform to Performance Technologies applicable specifications or if appropriate to Buyer s specifications accepted by Performance Technologies in writing If products sold hereunder are not as warranted Performance Technologies shall at its option refund the purchase price repair or replace the product provided proof of purchase and written notice of nonconformance are received by Performance Technologies within 12 months of shipment or in the case of software and integrated circuits within ninety 90 days of shipment and provided said nonconforming products are returned F O B to Performance Technologies s facility no later than thirty days after the warranty period expires Products returned under warranty claims must be accompanied by an approved Return Material Authorization number issued by Performance Technologies and a s
83. pool in parentheses the current number of Data Blocks in use the high watermark max of allocated Data Blocks the total number of buffers in the pool and the number of times that an allocation request to this Data Block pool has been issued and has failed Note that each dblk pool is displayed in order of ascending size of the frames it supports If the db k line for a pool displays failures this is an indication that the buffer allocation was attempted from the following db k pool total dblks This line is a summation of the four lines that precede it in the report and represents the aggregate Data Block pool usage for this controller This line reports the current number of Data Blocks allocated by the controller the high watermark max of allocated Data Blocks the total number of available Data Blocks and the number of times that an allocation request to any Data Block pool has been issued and has failed total mblks This line reports the Message Block pool usage The Message Block is a structure that is allocated for each Data Block available to the system it is a control structure that provides linkage to the Data Block and to other Message Blocks on the same queue The total number of Message Blocks available to the controller is equal to the total number of Data Blocks configured for the controller i e the aggregate number of blocks in the four defined Data Block pools see below This line reports the current number of Me
84. presents information for users of Performance Technologies Inc products Although the information contained within this document is considered accurate and characteristic of the subject product Performance Technologies Inc reserves the right to make changes to this document and any products described herein to improve reliability functionality or design Performance Technologies Inc does not assume any liability arising out of the application or use of any product or circuit described herein No part of this document may be copied or reproduced in any form or by any means without the prior permission of Performance Technologies Inc Compliance with RoHS and WEEE Directives In February 2003 the European Union issued Directive 2002 95 EC regarding the Restriction of the use of certain Hazardous Substances in electrical and electronic equipment RoHS and Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE This product is compliant with Directive 2002 95 EC It may also fall under the Directive 2002 96 EC PT s complete position statements on the RoHS and WEEE Directives can be viewed on the Web at http pt com assets lib files pdfs rohs policies rohs weee statement pdf Contents Q gu LL id Chapter 1 About This Guide 7 rc PPM STS 7 Text Conventions ceu acea Gade ner x qu Ginga Ride da Ro qe aed c son giai e RC IRR dr 7 Customer Support and Services i i is cee ibaa ER ERREUR RARO
85. pt builds the portions of the product that execute on the local system These include the API and the download configuration and test utilities The API archive libMPS a is copied to usr lib The device driver object file is copied to usr kernel drv and is loaded into the kernel 6 Skip this step if either you accepted in Step 5 the default symbolic link from the installation directory to usr pti or you are installing for a NexusWare CPC388 The load command file in the main pti directory contains the names of the executable files that are loaded to the communication controller or server This file is used during the load procedure and must contain the correct full pathname of each executable file If you did not allow the install script to create the default symbolic link the pathnames in the load command file is incorrect In this case you must edit the command file and modify the pathname of each executable file The command file is called Cmdfile prot where prot is a filename extension identifying your specific protocol or configuration Below a sample file is shown with the default pathnames and then after modification to accommodate the alternate installation directory home tools Note that the details of your file will not exactly match the examples shown here BTYPE O PTI334 LOADCTLR 0 usr pti Load xstra pci334 hdlc 0 L 0 0x405e00 0x405e00 LOADCTLR 0 usr pti Load hif pci334 hdlc 0 L 1 Ox40fe00 0x0 LOADCTLR 0 usr pti
86. ptor to an embedded controller and you should unload it when it is no longer in use The insmod and rmmod commands are used to load and unload a kernel module respectively lsmod displays a list of all modules currently loaded in the kernel 7 Skip this step if you are installing the client software for use with a NexusWare Controller You may also skip this step if your xSTRa based software in the default usr directory The load command file is usr pti Cmdfile prot where prot is a filename extension identifying a specific software product or configuration The load command file contains the names of the executable files that are loaded onto the communication controller or server This file is used during the download procedure and must contain the correct full pathname of each file Since you did not install the PT software in the default directory the pathnames in this file are incorrect and must be updated The easiest solution is to create a symbolic link named usr pti that points to the alternate installation directory For purposes of example assume that the alternate installation directory for the PT software is opt tools root ln s opt tools pti usr pti root Protokit Software Installation If for some reason this solution is not acceptable you must edit Cmdfile prot and modify the pathnames of the files Below a sample load command file is shown with the default pathnames and then after modification to accommoda
87. rameter is timeslot number 2nd parameter channel 0 31 links 32 63 3rd parameter bitmask 64K means use all bits in timeslot 56L means mask LS bit in timeslot 56M means mask MS bit in timeslot 4th parameter operating mode hdlc default clear timeslot 1 0 64K hdlc timeslot 2 1 64K blank timeslot 3 2 64K clear timeslot 24 23 64K hdlc Chapter 4 QMC Configuration Guide a_i Table 4 2 E1 Configuration Details Parameter Possible Values Default Value encoding HDB3 or AMI HDB3 signaling CCS or CAS CCS crc4 on off on alarms on off on clocking internal external or recovered internal maxframe any up to max configured buffer size 2048 timeslot timeslot 1 31 timeslot n channel n 1 channel 0 31 bitrate 64K bitrate 64K 56L 56M mode HDLC mode HDLC or clear Running the QMC Configuration Utility The QUICC Multichannel Controller Configuration Utility gmc may be used to get or set T1 E1 configuration parameters or to obtain current status and statistics relating to the T1 E1 span Note that running the gmc utility is optional i e you are not required to run the gmc utility in order to commence data transfer options The QMC is initialized with the default values for all parameters as outlined in the previous sections The qmc utility may be executed any time after the software has been downloaded to the controller However a reconf
88. roller There are two connectors designated as port 0 and port 1 These are synonymous with spans 0 and 1 buildout is an integer value 0 7 that specifies the amount of energy used to drive the T1 signal down the span It is a function of distance and will provide a hot signal for longer distances in a DSX 1 digital cross connect application or provide a dB gain factor in the case of a CSU application The following table lists the possible values for buildout ValueLine Buildout Application 0 0 to 133 feet 0 dB DSX 1 CSU 1 133 to 266 feet DSX 1 2 266 to 399 feet DSX 1 3 399 to 533 feet DSX 1 4 533 to 655 feet DSX 1 5 7 5 dB CSU 6 15 dB CSU 7 22 5 dB CSU The default value for buildout is O framing framing defines the type of framing used on the span which must match the type of framing used by the connecting equipment ESF Extended Super Frame SF Super Frame Extended Super Frame is the default and is used in most modern day equipment With this framing type a CRC is generated on transmission and checked during receipt for every extended superframe This provides a mechanism for ensuring the integrity of the span encoding defines the method of encoding to be used on the span B8ZS Bipolar 8 Zero Substitution AMI Alternate Mark Inversion T1 Configuration Parameters i LLL APL AAA B8ZS encoding is a method of replacing a string of eight consecutive zero bits with a binar
89. s a destination network the second address is the gateway to access the network For example suppose the server s Internet address is 206 251 239 143 and the client s Internet address is 204 250 22 30 These addresses both begin with binary bits 110 and are therefore class C addresses but they have different network identifiers The server accesses the client via a gateway Suppose the gateway on the server s local area network has Internet address 206 251 239 129 This configuration is present in the server s routing tables as follows 204 250 22 30 206 251 239 129 The first entry is the address of the client The second is the address of the gateway on the server s local area network that the server uses to access the client If a client s Internet address indicates a different network identifier but there is no entry for the client in the server s routing tables the server looks in the routing tables for a default gateway If a network address of 255 255 255 255 exists in the table then the server uses the corresponding gateway address as its default gateway Chapter 3 Network Configuration C ee The following entry in the routing table indicates that the host at Internet address 206 251 239 129 is a default gateway 255 255 2554 255 205 251 239 129 If your network uses subnet addressing you can provide your subnet mask to the server with an entry in the routing tables If a network address exists in the table that is the s
90. s parameter identifies the target server This is the logical host name as specified in the client s hosts database S service This parameter identifies the service name to be accessed as specified in the client s services database If this option is not specified the service name defaults to mps v This option causes commreset to display status information during execution of the reset request For example to reset server alpha commreset alpha or commreset s alpha Appendix A eam teI E m Network Load Procedures SSS Overview After completing the hardware and software installation and the configuration procedures described in this document the server is ready to be loaded with its runtime software To initiate the download procedure you can select X from the configuration menu depress the reset push button on the server s front panel MPS 3000 family servers only or cycle the power off and on Any of these actions cause the server s PROM resident boot code to automatically begin the load sequence by attempting to contact over the Ethernet the first Internet address in the list of clients configured to load the server The configuration information is either entered at the console or retrieved from the Ethernet network using the Bootstrap Protocol MPS 300 or 600 servers only and the Trivial File Transfer Protocol After reset or power on there is an initial delay of five seconds to allow access to th
91. section Chapter 3 Network Configuration Chapter 4 eee m H p E y QMC Configuration Guide SSS Overview This chapter does not apply to controllers running PT s NexusWare Please refer to the NexusWare WAN Protocol Configuration Guide 106P0150 that came with your NexusWare controller for use of the NWC configuration utility A special configuration utility is provided for controllers running with the QUICC Multichannel Controller QMC All PT 37x 38x PowerQUICC controllers use the QMC Source code for the configuration utility qmc c is included with the release in the HDLC config directory The installation procedure builds the utility gmc and copies it to etc in the UNIX environment The QMC utility reads configuration parameters for each physical connection called a span from a text file Sample configuration files t config and e1config are also included in the HDLC config directory and copied to etc by the installation script The sample files contain default parameters to initialize one or both spans on the controller You should modify the appropriate configuration file according to your specific site requirements The following topics are covered in this chapter e QMC Configuration File Format on page 43 T1 Configuration Parameters on page 44 E1 Configuration Parameters on page 48 Running the QMC Configuration Utility on page 52 QMC Configuration File Forma
92. sed c ctlrnum Load only controller number ct rnum ignore load instructions in the command file for any other controller If this option is not specified on a Unix based system all controllers in the command file will be loaded The ctlrnum option is required for a Windows based system r Reset but not download the specified controller number c ctlrnum In this case a command file should not be specified v Verbose Print the status of each step of the commload process reset load exec If this option is not specified commload generates no output unless an error is encountered i Will print out the version strings of the currently loaded device driver the PT API library and all the modules specified in the command file Cmdfile xxx This is for informational purposes only If the i option is specified the card will not be loaded To download an embedded controller on a Unix based system type the following command commload v Cmdfile prot To download an embedded controller on a Windows based system commload v c0 Cmdfile prot Be sure to replace the characters prot with your actual filename extension As shipped the load command file contains instructions for loading controller zero If you have a second controller installed in your system you will need to create an additional load command file for that controller The load command file looks something like this for a UNIX based system BTYPE 0 PCI334 Ma
93. ssage Blocks allocated by the controller the high watermark max of allocated Message Blocks the total number of available Message Blocks and the number of times that an allocation request has been issued that has failed memory avail This line reports the current amount of memory available and the low watermark min since the system has been operational electrical interface These lines apply only if the server or controller has a serial interface If so the electrical interface is reported for each serial port A few guidelines To determine the factory settings of the db k pools use Communications Server Update Program commupdate on page 57 to display the current settings The db k pools should only be modified if performance problems occur You should always back up the configuration files before modifying the settings so that you can return to the factory settings LAN Server Reset Utility commreset BE DALAL LAPD If one or more of the dbik pools in the report indicate under utilization of that pool for instance the current and max lines are both zero after extensive use of the controller you might consider modifying the dblk pool definitions to provide more buffers of a different size dblk pool and eliminate the db k pool that is not being used at all If a dblk pool exhibits large numbers of failures you may need to evaluate the frame size you are configuring for the protocol and comparing it with the current d
94. t The QMC utility uses the information in the configuration file to configure spans on the controller The parameters specified in the file determine the corresponding parameters of the T1CONFIG or E1CONFIG structure This structure is defined in the file hdlchar h located in the hdlc include directory Once all parameters have been extracted from the configuration file and validated the QMC utility sends a 7 CONFIG REQ ioctl command via an MPSioctl API call to execute the reconfiguration request Each entry in the configuration file is composed of a parameter keyword followed by a corresponding parameter value or values The file is divided into sections where each section configures a single span and contains an entry for each defined parameter The following general rules apply The first keyword of each section must be span This is the only required keyword Other keywords may be listed in any order Each keyword must be followed by a valid parameter on the same line separated by white space one or more spaces and or tabs Keywords and parameters may be entered in either upper or lower case Chapter 4 QMC Configuration Guide Blank lines and unrecognized entries are ignored Comments may be included anywhere in the file prefaced by a character T1 Configuration Parameters The keywords and valid parameter values for T1 controllers are listed below span specifies the physical connection on the cont
95. t value when this option is not specified depends on the operating system on which commstats is executing see the MPSOPEN IPV6 SCOPEID DFLT symbol definition in lt usr pti include mpsipv6 h ethO for Linux hmeO for Solaris and 8 for Windows This option is ignored for non NexusWare LAN servers embedded controllers and IPv4 sockets to a NexusWare server d Debug mode Outputs detailed information about every stream currently active on the target controller or server This option is provided as a debugging aid for software developers Not valid for NexusWare Controllers i Controller identification applies to embedded controllers only This option causes commstats to display the type of controller and its geographic address if NexusWare Controller for every device identified by the PT host device driver during system startup Also included in this report will be the version string of the current PT host device driver that is installed in the system V Displays the version string of the MPS API with which the utility was built Note The number of buffers reported when using commstats will never be zero since buffers are required on the controller server to process the commstats request For example to request statistics from embedded controller commstats c 0 To request statistics from the server alpha commstats s alpha Interpreting the System Statistics Report of a Non NexusWare Platform There are sever
96. tatement of the reason for the return Please contact Performance Technologies or its agent with the product serial number to obtain an RMA number If Performance Technologies determines that the products are not defective Buyer shall pay Performance Technologies all costs of handling and transportation This warranty shall not apply to any products Performance Technologies determines to have been subject to testing for other than specified electrical characteristics or to operating and or environmental conditions in excess of the maximum values established in applicable specifications or have been subject to mishandling misuse static discharge neglect improper testing repair alteration parts removal damage assembly or processing that alters the physical or electrical properties This warranty excludes all cost of shipping customs clearance and related charges outside the United States Products containing batteries are warranted as above excluding batteries THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS IN NO EVENT SHALL PERFORMANCE TECHNOLOGIES BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES DUE TO BREACH OF THIS WARRANTY OR ANY OTHER OBLIGATION UNDER THIS ORDER OR CONTRACT Chapter 1 About This Guide Chapter 2 Saar a F Software Installation SSS Overview This chapter contains basic software i
97. te the alternate installation directory opt tools Note that the details of your command file will not exactly match the example shown here Before BTYPE 0 PCI334 LOADCTLR 0 usr pti Load UC pci334 dfx 0 L 0 0x802000 0x0 LOADCTLR 0 usr pti Load hdlc pci334 dfx 0 L 1 0x806b30 0x0 LOADCTLR 0 usr pti Load xstra pci334 dfx 0 L 2 0x80cb40 0x80cb40 LOADCTLR 0 usr pti Load config dfx 0 L 3 0x80a320 0x0 NIT L2 After BTYPE 0 PCI334 LOADCTLR 0 opt tools pti Load UC pci334 dfx 0 L 0 0x802000 0x0 LOADCTLR 0 opt tools pti Load hdlc pci334 dfx 0 L 1 0x806b30 0x0 LOADCTLR 0 opt tools pti Load xstra pci334 dfx 0 L 2 Ox80cb40 0x80cb40 LOADCTLR 0 opt tools pti Load config dfx 0 L 3 0x80a320 0x0 INIT L 2 Protokit Software Installation This section contains basic Protokit software installation instructions for Solaris 2 x host Systems This section is not applicable for NexusWare products CPC388 ProtoKit is shipped on two CDROMs one containing the Protokit itself and the other containing the GNU software development tools which are used to build software that runs in the xSTRa environment on a PT server or controller The instructions below explain how to install Protokit and extract the GNU tools from the distribution media Installation of the source level debugger is described in Installing the PT Client Software on page 18 Follow the instructions in this section in order before proceeding with the inst
98. th the controller will provide the information required to alter the amount of on board memory This additional memory is made available for the protocol software and is used by the data and message blocks Communications Server Update Utility Communications Server Update Program commupdate Buffer Pool Configuration Update Memory Size MPS Server Specific Save Configuration File Updates Quit O BP WBN H Enter Menu Item 1 gt 2 WARNING If you modify the memory size you MUST be sure that the server controller hardware has sufficient memory onboard Current memory size is 16 MB Enter new memory size in MB 4 8 16 or 32 gt 16 MEMORY SIZE 16777216 Code data reserved areas 455184 System memory 120196 Data Message blocks 10060040 Drivers Stream Head 2248 TCP memory 264448 TOTAL USED 10902116 Estimated memory available 5875100 Communications Server Update Utility 1 Buffer Pool Configuration Update Memory Size MPS Server Specific Save Configuration File Updates Quit O 8 WN Enter Menu Item 1 gt 4 Do you really want to update Load config hdlc mps800 H n gt y Communications Server Update Utility Buffer Pool Configuration Update Memory Size MPS Server Specific Save Configuration File Updates Quit OP w u H Enter Menu Item 1 gt 0 Chapter 5 Client Utilities Modifying the MPS Server Specific Options The MPS server specific options allow for alterations of the de
99. the PT Software a Found New Hardware Files Needed Window will appear on your Windows desktop Disregard this window until you have installed the PT Software and reboot your system The software installation is started by double clicking on the Setup exe application that is on the provided CDROM You will see the PT welcome screen displayed click next The software licence agreement will then be displayed read the terms and click yes to accept the agreement You will then be asked to choose a destination folder for the installation The default directory is c pti The directory that you specify for the software to be installed will become your machine s pti directory and will have an environment variable called PTI to refer to it You must then select the hardware platform to install Choose the embedded communications controllers to install Finally the installation asks if you want to reboot your computer You must reboot your computer for the software installation to complete Remember to reboot before you try to use the PT software Note After rebooting your system there will be a Found New Hardware Files Needed window on your desktop From this window for Windows 2000 users specify cAPTADRIVERSWIN 2K For all other Windows types specify c PTI DRIVERS OTHER Note The Hardware Installation Wizard will present the following warning The software you are installing has not passed Windows Logo testing Select the Continue Anyway op
100. the full path name of the PT server s download command file For example FILE usr pti Cmdfile x25 After the server reads the configuration file and stores the content in flash PROM non volatile memory it retrieves usr pti Cmdfile x25 to obtain a list of the files that are to be loaded into RAM DIAG The DIAG command configures an MPS3000 and MPS300 600 server to run in a diagnostic mode The command is followed by the responses to the following questions Are diagnostics supported y or n Configuring the Server Enter diagnostic TCP port number decimal Enter diagnostic UDP port number decimal Invoke diagnostic mode upon exiting y or n If the first argument is n the rest of the command is ignored For example DIAG n Diagnostics not supported USER The USER command allows the user area of flash PROM to be set The command is followed by a hexadecimal offset from the beginning of the user flash PROM area and a hexadecimal value for the byte at that offset For example the following enables the auto reset feature Enable auto reset USER 0 0 USER 1 0 USER 2 OxA0 USER 3 OxDO ROUTE The ROUTE command allows the user to specify three items of information that relate to TCP IP routing e The Internet address of gateways that can be used to access a different network The Internet address of a default gateway Asubnet mask Each ROUTE command is followed by two Internet addresses in decimal dot notation
101. tion The host machine communicates with the communications controller through the device driver ntmps sys During the installation the ntmps device driver is set up to load automatically at machine startup You can change this setting or load and unload the driver manually through the Control Panels Devices applet There will be a new registry entry ntmps created in the HKEY LOCAL MACHINE SYSTEM CurrentControlSet Services area Also the event log service will be modified to enable it to log messages from the ntmps device driver Remember to reboot the machine after the device driver is installed manually Chapter 2 Software Installation For the embedded Windows driver the application that loads the card commload has to be run a little bit differently The controller to be loaded must be specified on the command line For instance even if just one controller is resent in the Windows machine the command line for the commload should be commload v c 0 Cmdfile prot the actual name of the command file will vary depending on the protocol software If the controller number is not specified the commload program will fail Note that the loading of modules is not applicable for a NexusWare Controller CPC388 CPC358 and PCI384 For Windows systems that support Power Management the embedded device driver ntmps will allow both Standby and Hibernate requests if there are no open connections to a PTI communications controller If
102. to the largest Note that buffer sizes will be rounded up to multiples of 16 Class 1 Enter block size 64 gt Enter Number of blocks to build 14000 gt 12000 Class 2 Enter block size 528 gt Enter Number of blocks to build 8000 gt 2500 Class 3 Enter block size 1040 gt Enter Number of blocks to build 4000 gt 3000 Class 4 Enter block size 2064 gt 4112 Enter Number of blocks to build 2000 gt 1000 New Configuration Class 1 Size 64 Number 12000 Class 2 Chapter 5 Client Utilities Size 528 Number 2500 Class 3 Size 1040 Number 3000 Class 4 Size 4112 Number 1000 MEMORY SIZE 16777216 Code data reserved areas 455184 System memory 120196 Data Message blocks 10060040 Drivers Stream Head 2248 TCP memory 264448 TOTAL USED 10902116 Estimated memory available 5875100 Communications Server Update Utility 1 Buffer Pool Configuration 2 Update Memory Size 3 MPS Server Specific 4 Save Configuration File Updates 0 Quit Enter Menu Item 1 gt 4 Communic OP WN FE Ente Do you really want to update Load config hdlc_mps800 H ations Server Update Utility Buffer Pool Configuration Update Memory Size MPS Server Specific Save Configuration File Updates Quit r Menu Item 1 gt 0 Update the Memory Size With some PT s controllers the amount of physical memory on the controller may be modified The hardware manual that was supplied wi
103. ts zero and one must have the same assignment ports two and three must have the same assignment and so on Thus the ELEC command has 1 or 4 parameters designating the line interface for ports 0 1 2 3 4 5 and 6 7 Each parameter must be either RS232 or RS530 In the example below ports 0 1 and 4 5 are RS232 and ports 2 3 and 6 7 are RS530 ELEC RS232 RS530 RS232 RS530 SNTP Configuration The MPS 800 and MPS 300 600 servers can use the Simple Network Time Protocol SNTP to maintain and synchronize a local system clock to a reference clock provided by a Network Time Protocol NTP or SNTP Server This option provides the ability for PT serial protocols to then timestamp serial data traffic with the Universal Coordinated Time UTC time of day When used with an accurate reference clock such as that provided by Global Positioning System GPS this option allows the MPS server to provide timestamping capability for received serial data traffic to the nearest millisecond Once the 7 option is selected you are prompted for the Internet address of the NTP server platform This platform must be an NTP or SNTP server on your local subnet in order to provide clock synchronization to the nearest millisecond After entering this address you are prompted for the Poll Frequency Code value This value translates into the number of seconds between polls to the NTP server in terms of powers of 2 For instance the value 4 designates polls to the NTP ser
104. umber must be added to the services file SystemRoot system32 drivers etc services on the client The entry should look something like this mps 5555 tcp TCP normal mode A client application uses the service name in the first column to establish a connection to the server through the PT API You should always use the service name mps The port number in the second column must be followed by tcp which specifies the protocol used to access the server The port number shown above is an example and may be changed following these guidelines Use values between 5000 and 65 535 decimal and check the existing entries in the services database to be sure that the values you choose are not already assigned to another service The port number assigned must be the same on all clients that access the server The final column contains an optional comment designated by the character To establish a connection to the server the API also requires the server s logical host name and Internet address to be added to the hosts database SystemRoot system32 drivers etc An entry in this file looks something like the following example 100 0 0 8 indiana indy hoosier The first column contains the Internet address in the standard dotted format In this example the host name is indiana with indy and hoosier as aliases or nicknames which can be substituted for the host name The Internet address you use must be consistent with your network
105. uration should not be used and default controller assignments will be performed This value is set to zero at installation time ControllerEntries is a list of controller bus device numbers for each PT controller assignment This is a comma and space separated list and specifies controller number bus number device number on each line At install time sample values are issued just to show the format method note having 1s at the end is required If physical assignments are desired a registry editor utility like regedt32 must be used to define the appropriate system Chapter 2 Software Installation General Usage Suggestion To come up with appropriate controller bus device numbers for your specific system we recommend to insert the PTI cards in the positions you desire and have the Host mps driver load the default way for the first time At that point run commstats i and then use the values it returns in the configuration file Chapter 3 E SaaS e Network Configuration SSS Overview This chapter contains basic instructions to configure your hardware to operate over your TCP IP Network Chose the appropriate section for your hardware and follow the instructions in that section The following topics are covered in this chapter Embedded NexusWare Controller on page 27 e MPS1000 on page 28 e MPS800 MPS600 and MPS300 on page 28 e Configuring a Client on page 28 Configur
106. ures are configured by entries in this area of flash PROM Auto Reset The server can be configured to perform an automatic software reset when unrecoverable errors are detected The reset concludes with downloading the server and restarting operation To enable the auto reset feature the first four bytes of the user flash area starting at offset 0 must be set to 0x00 0x00 OxAO and OxDO If any other values are used when the server detects an unrecoverable error it prints diagnostic information at the console device and halts Network Reset The server has the ability to be reset over the Local Area Network and by default is set to allow this action See commreset and commload in LAN Server Reset Utility commreset on page 67 and Download Program commload on page 55 for further information If security is a concern and only a physical reset pushing the reset button or cycling power can be allowed the address Ox3fe of the user defined flash prom should be set to a value other than 0x00 Configuring the Server System Report The server can be configured to generate a report at the console device on a periodic basis The System Report includes statistics on the usage of buffers and memory by the server To enable display of the System Report the last byte of the user flash area offset Ox3ff must be modified to a nonzero hexadecimal value between 1 and Oxff which specifies the frequency in seconds for the report The Syst
107. ver every 16 seconds the value 5 designates polls to the server every 32 seconds and so on The valid range of entries is 4 to 14 which is the complete valid range proscribed in the SNTP specification However for practical use with a PT server the subset 4 to 7 is highly recommended and ideally one should specify 4 If SNTP is no longer required specifying a Poll Frequency Code of 0 will disable the SNTP feature The factory setting is to disable SNTP Note The Universal Coordinated Time is the number of seconds and in this case microseconds that have elapsed since January 1 1970 at the zero meridian of Greenwich England This format is used by most computer systems to provide a time value that is independent of time zone and daylight savings time concerns Consult the Programmer s Guide s for the serial protocol s you have purchased for more information on how timestamps are reported Write New Flash Program The MPS 800 supports updating the Boot Flash code in the field This is not a part of the configuration process but can be helpful in certain maintenance situations The command causes a program in the Boot Flash code to be copied to RAM This program erases the existing Boot Flash code reads a new Boot Flash image from the boot client via TFTP programs the Boot Flash device with the image and then transfers control to the Boot Flash device Configuring the Server T If you are provided with an updated Boot Flash imag
108. y pattern that will maintain a one s density on the line This is necessary to keep the clocking synchronized between the communicating systems All data type applications where data can be passed with 8 or more consecutive zero bits require B8ZS encoding this is the default AMI encoding specifies that logic one bits alternate polarity positive negative If for any reason the data stream is not set to B8ZS at the other end of the span AMI encoding should be selected alarms enables disables alarms The alarms function is not implemented in this release clocking specifies the type of clocking used for the transmit side of the framer The receive side clocking is always derived from the span The transmitter however can derive clocking from three different sources EXTERNAL refers to an external clock supplied at the inputs of the sync port located on the board This option is used when a reference clock is being supplied by some other piece of equipment INTERNAL refers to the on board oscillator which supplies a stratum 4 clock source to the transmitter Stratum 4 has a requirement of 30ppm parts million tolerance and is used in CPE end equipment This option is used when the board is the reference point for the clocking within the system RECOVERED refers to using the recovered receive clock as the source for the transmit side This option is used when the board is slaved to the communicating equipment at the other end