1. 5 Consult your rack enclosure manufacturer s recommendations for specific rack mounting hardware that will be required 6 The holes on the rack mount bracket are notched for easy installation Tighten the PDU securely to the rails and then follow the startup directions for the PDU in the previous section PDU 16 connections Rack Mounting Brackets Figure 4 PDU 16 with rack mounting brackets THIS MANUAL IS PROPERTY OF SOCOMEC UPS ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN Chap 4 Page 7 11 ENGLISH 5 INDICATOR LAMPS 5 1 MAINS INDICATOR LAMP This orange lamp is illuminated when mains power is present see Figure 5 It signals that you may transfer the loads to maintenance bypass MAINS mode operation via the rotary switch During a mains power outage this lamp will be off and the UPS will supply battery back up power to the connected loads 5 2 UPS INDICATOR LAMP This green lamp is illuminated when there is output power available from the UPS see Figure 5 It signals that it is safe to transfer the connected loads from mains power back to UPS output power Green lamp Orange lamp Output power available from UPS MAINS power present Rotary switch Figure 5 Indicator lamps on PDU 16 Chap 5 Page 8 11 THIS MANUAL IS PROPERTY OF SOCOMEC UPS ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN 6 1 TRANSFER TO MAINTENANCE BYPASS To transfer to maintenance bypass mains fro
2. instructions before operating the PDU 16 and the connected UPS system Adhere to all warnings on the unit and in this manual Follow all operating and user instructions Turn the UPS off and unplug the PDU 16 before cleaning Use only a soft cloth never liquid or aerosol cleaners The UPS and PDU 16 are designed for data processing equipment Do not plug laser printers or appliances such as hair dryers heaters vacuum cleaners or electrical drills into the UPS output sockets DO NOT MODIFY THE CABLES IN ANY WAY THE PDU SOCKETS SHOULD MATCH THE UPS SOCKETS THE PDU 16 MUST BE EARTHED AT ALL TIMES WHILE IN USE TURN OFF THE UPS BEFORE UNPLUGGING IT The UPS and the PDU 16 are equipped with earthed plugs plug types vary depending on model Do not defeat the safety purpose of this plug If unable to fully insert the plug into the designated socket contact a qualified electrician or your local dealer or representative for assistance Route power supply cords so they are not walked on or pinched in any way Risk of electric shock do not remove cover no user serviceable parts inside Refer servicing to qualified service personnel This device receives power from multiple sources Before servicing this device remove all connections Before servicing the UPS follow Maintenance of UPS instructions in the user manual for your UPS For use in a controlled environment Refer to manual specifications for environmental condi
3. ASOCOmec Innovative Power Solutions UP y AN pe PDU 16 OPERATING MANUAL ON Oo 5 ON INDEX CERTIFICATE AND CONDITIONS OF WARRANTY SAFETY INTRODUCTION AND SYSTEM DESCRIPTION RACK MOUNT INSTALLATION INDICATOR LAMPS OPERATION TECNICAL DATA TROUBLESHOOTING 1 1 CERTIFICATE AND CONDITIONS OF WARRANTY pdu16 08 01 This SOCOMEC SICON EQUIPMENT is guaranteed against manufacturing and material defects for a period of 12 months from the date of purchase This certificate of warranty must NOT be sent back but must be kept by the customer together with the purchase receipt to be used if the product should require interventions while under warranty The period of validity of the warranty is calculated from the date of purchase of the new product by the final user from an official reseller the date shown on the purchase receipt is used as proof The warranty is of the carry in type free supply of parts and labour for repairs with return of a product to be replaced to SOCOMEC UPS or authorized centres at the customer s cost and risk In order to use the warranty service the user must respect the following rules the product must be returned exclusively in its original packaging Any damage caused during shipping packaging other than the original is not covered by the warranty the product must be accompanied by proof of purchase a document bill invoice receipt showing the date of pu
4. Model Label on MicroPDU This PDU 16 is intended for use with a UPS meeting all the following requirements UPS input cord is compatible with the rating and type of socket on the PDU 16 labeled CONNECT UPS LINE CORD HERE UPS output socket is compatible with the PDU 16 input power connector labeled UPS e Available mains socket is compatible with the PDU 16 input power connector labeled MAINS The user must provide a suitable mains power cord with the appropriate country connector This will usually be the original UPS power cord which has been removed from the UPS mains output Chap 7 Page 10 11 MANUAL IS PROPERTY OF SOCOMEC UPS ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN 8 1 TROUBLESHOOTING 8 TROUBLESHOOTING pdu16 07 01 Problem Cause Solution MAINS lamp orange not illuminated Mains not present Call qualified service personnel to restore power to socket Input cord not connected to mains Refer to PDU 16 installation instructions in this manual UPS Available lamp green not illuminated UPS output power not present UPS input and or output cord not connected to PDU 16 Turn on UPS Refer to UPS user manual Refer to PDU 16 installation instructions in this manual m 2 G I PDU 16 will not start some all connected loads PDU 16 circuit protectors trip after resetting PDU 16 output
5. circuit breaker has tripped Overcurrent on PDU 16 socket Reset PDU 16 circuit protectors Recalculate load requirements distribute load among other PDU 16 16 sockets THIS MANUAL IS PROPERTY OF SOCOMEC UPS ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN Chap 8 Page 11 11
6. m UPS use the following steps 1 2 3 4 5 Troubleshooting section the PDU 16 Turn the UPS off Disconnect the two cables connecting the UPS to the PDU 16 You may now service the UPS 6 2 TRANSFER TO UPS To transfer to UPS from maintenance bypass mains use the following steps 1 2 user manual section Conditioned power is now being supplied through the UPS THIS MANUAL IS PROPERTY OF SOCOMEC UPS ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN Chap 6 Page pdu16 05 01 Ensure the MAINS lamp orange is illuminated If the lamp is not illuminated refer to Transfer the rotary switch from UPS to MAINS provide the MIANS lamp is illuminated on pdu16 05 02 Reconnect the UPS to the PDU 16 Start the UPS according to the instructions in the UPS Verify that UPS lamp green on the PDU 16 is illuminated If so transfer the rotary bypass switch from MAINS to UPS If the lamp does not illuminate refer to Troubleshooting 9 11 SEERNE ENGLISH 7 1 TECNICAL DATA pdu16 06 01 Transfer Time to and from 6ms maintenance bypass Operating Ambient Temperature 0 C to 40 C 32 F to 104 Storage Ambient Temperature 20 C to 60 4 F to 140 F Dimensions W x D x H mm in 88 x 77 x 394 3 5 x 3 0 x 15 5 Weight kg Ibs 4 5 10 Humidity 0 to 9596 non condensing Agency Standards CE EN 60950 ISTA Procedure 1A Electrical Rating See
7. rchase and the information necessary to identify the product model serial number The number of the authorization for return for repairs must also be attached with a detailed description of the defect found in the product If any of these elements is missing the warranty is invalid The return authorization number is issued by the service centres by telephone on receiving notification of the malfunction if it is not possible to provide proof of purchase the serial number date of production will be used to calculate expiry of the warranty which may lead to a reduction in the product s warranty period The product is not covered by warranty for damage caused by negligence use outside the tolerance ranges electric power supply lightning humidity temperature bad ventilation etc tampering or any unauthorized intervention During the warranty period SOCOMEC UPS may at its discretion decide to repair the product or replace the defective parts with new parts or with used parts that are equivalent to new parts in terms of functions and performance In the case of the battery the warranty is valid if periodic recharging has been effected within the terms indicated on the packaging It is advisable therefore after purchase to check that the date of the next recharging has not passed OPTIONAL Warranty for the optionals is 12 months and is of the carry in type Software products Warranty for the software is 90 days The sof
8. the power is routed around bypassing the UPS system see Figure 2 Mains power is supplied directly to the load through the PDU 16 back up conditioned power NOT available during the MAINS mode of operation MAINS maintenance bypass mode ou Figure 2 The UPS may be turned off and removed without affecting the load Chap 3 Page 6 11 THIS MANUAL IS PROPERTY OF SOCOMEC UPS ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN 4 PDU INSTALLATION 4 1 PDU 16 connections UPS INPUT MAINS INPUT Connect to load socket on rear Rotary switch and power Connect to mains wall socket Use of UPS Cable supplied indicator lamps original UPS mains input cord SEERNE ES Connect UPS input cord here gt gt Figure 3 Connect loads Cable supplied Connect loads 42 RACK MOUNT INSTALLATION 1 Rack mount installation of the PDU 16 is possible with the use of the rack mounting brackets shipped with the PDU See Figure 4 2 The rack mount brackets allow you to rack mount the PDU 16 in a 19 enclosure 23 to 19 rack adapters would have to be purchased separately if you are using the 23 or equivalent cabinet 3 PDU 16 can be mounted to face one of four directions depending on your application and utilizing the rack mount brackets provided 4 Determine the desired position and direction for the PDU face it in that direction then attach the brackets to the PDU with the screws provided
9. tions g WHEN THE PDU 16 IS IN MAINS POSITION MAINTENANCE BYPASS MODE THE POWER TO THE CONNECTED LOAD IS NOT FILTERED OR CONDITIONED BY THE UPS CONNECTED EQUIPMENT GUARANTEE IS NOT VALID WHILE IN THIS MODE OF OPERATION Chap 2 Page 4 11 THIS MANUAL IS PROPERTY OF SOCOMEC UPS ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN 2 2 GLOSSARY OF SYMBOLS pdu16 01 02 PDU POWER DISTRIBUTION UNIT Indicates Input gt gt Indicates AC Output AA Consult the manual for additional information SEERNE MAINS lamp indicates local power is available and the load may be transferred to bypass MAINS UPS A05 THIS MANUAL IS PROPERTY OF SOCOMEC UPS ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN Chap 2 Page 5 11 ENGLISH 3 1 INTRODUCTION pdu16 02 01 Congratulations on your choice of the PDU 16 The PDU 16 provides maintenance bypass capability as well as power output distribution The PDU 16 can be used on UPSs in the rack mount or tower configuration The PDU 16 provides an isolated path of power for your UPS system for preventive maintenance or service 3 2 SYSTEM DESCRIPTION The PDU 16 has two modes of operation UPS UPS available and MAINS maintenance bypass In UPS mode the power is routed through the UPS system delivering conditioned power to the load as shown in Figure 1 Mains Connected loads UPS mode of operation Figure 1 In MAINS mode
10. tware is guaranteed to function in compliance with the manual and the written material accompanying the product Hardware accessories or supports e g disks cables etc attached are guaranteed from material and manufacturing defects under normal use and service for a period of 12 months from the date of purchase Under no circumstances will SOCOMEC UPS be responsible for damages including without limitations damage for loss of earnings interruption of activity loss of data or other economic losses deriving from the use of this product The present conditions are subject to Italian law All disputes to be heard by the Court of Vicenza THIS MANUAL IS PROPERTY OF SOCOMEC UPS ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN ENGLISH 2 1 SAFETY pdu16 01 01 DO SERVICE THIS PRODUCT YOURSELF OPENING REMOVING THE COVER MAY EXPOSE YOU TO DANGEROUS VOLTAGES EVEN WHEN THE AC CORD IS DISCONNECTED FROM THE ELECTRICAL SOCKET REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and operation of the PDU 16 This product is designed for commercial industrial use only with UPS systems It is not intended for use with life support and other designated critical devices Do not exceed PDU or UPS rating labels Do not exceed PDU or UPS rating labels Read all safety and operating
Download Pdf Manuals
Related Search
Related Contents
Disposiciones generales - Thies Textile Machines "取扱説明書" USER MANUAL - Terrain Vehicle NETBOX User's Manual - CONRAD Produktinfo. Le sar : mode d`emploi - Ministère de l`écologie, du développement Frigidaire 134940700A User's Manual Lindy 52058 WLAN access point Instruction Manual Manuel d`instructions 商品に添付してある取扱説明書はこちら(PDF - ta9nJapan Triarch 29230/1 User's Manual Copyright © All rights reserved.