Home
PDF User Manual
Contents
1. C9 Lumen8 Tri Pixel Panel 25 Code ELUMO85 USER MANUAL WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipment Do not open the equipment and do not modify the equipment Do not connect this equipment to
2. CH74 CH75 CH76 R25 G25 B25 0 100 0 100 0 100 78 channel mode DMX chart 16 23 24 31 G 32 39 40 47 RG 48 55 GB 56 63 RB 64 71 RGB 72 79 Colour 1 Dimmer 80 87 Colour 2 88 95 Colour 3 96 103 Colour 4 104 111 Colour 5 IIT Ser 120 127 Colour 7 sl w to fast 128 135 Colour 8 136 143 Dream 144 151 Meteor 152 159 Fade 160 167 Change 168 175 Flow 1 176 183 Flow 2 184 191 Flow 3 Speed 0 255 192 199 Flow 4 Slow to fast 200 207 Flow 5 208 215 Flow 6 216 223 Flow 7 224 231 Flow 8 232 239 Flow 9 240 255 Sound 0 255 100 channel mode DMX chart R1 G1 B1 Dimmer R2 G2 B2 Dimmer R3 G3 B3 0 100 0 100 0 100 1 0 100 0 100 0 100 2 0 100 0 100 0 100 0 100 0 100 CH13 CH14 CH15 CH16 CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24 R4 G4 B4 Dimmer R5 G5 B5 Dimmer R6 G6 B6 Dimmer 0 100 0 100 0 100 4 0 100 0 100 0 100 5 0 100 0 100 0 100 6 0 100 0 100 0 100 CH25 CH26 CH27 CH28 CH29 CH30 CH31 CH32 CH33 CH34 CH35 CH36 R7 G7 B7 Dimmer R8 G8 B8 Dimmer R9 G9 B9 Dimmer 0 100 0 100 0 100 7 0 100 0 100 0 100 8 0 100 0 100 0 100 9 0 100 0 100 0 100 CH37 CH38 CH39 CH40 CH41 CH42 CH43 CH44 CH45 CH46 CH47 CH48 R10 G10 B10 G11 B11 G12 B12 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 100 channel mode DMX chart cont CH49 CH50 CH51 CH52 CH53 CH54 CH55 CH56 CH57 CH58 CH59 CH60 R13 G13 B13 i R14 G14 B14 i R15 G1
3. Letters A Z Numbrs 1 9 Patterns __ os omoose 25C channel mode DMX chart Cool white 4 5 4 0 255 Cell 4 0 100 0 255 Cell 5 0 100 25W channel mode DMX chart Warm white 0 255 Cell 12 0 100 __13 0 255 Cell 13 0 100 0 255 Cell 25 0 100 1 2 3 4 5 7 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 5 26 channel mode DMX chart a Lo Ls sms emat As Cell 12 0 100 Y 75 channel mode DMX chart R1 G1 B1 R2 G2 B2 R3 G3 B3 R4 G4 B4 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 EN CH14 CH15 CH16 CH17 CH18 CH19 CH20 CH21 CH22 CH23 EN R5 B8 0 100 v T don EON ins Y 0 100 CH25 CH26 CH27 CH28 CH29 CH30 CH31 CH32 CH33 CH34 CH35 CH36 R9 R10 G10 B10 R11 G11 B11 R12 G12 B12 0 100 0 D 0 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH37 CH38 CH39 CH40 CH41 CH42 CH43 CH44 CH45 CH46 CH47 CH48 R13 G13 B13 R14 G14 B14 R15 G15 B15 R16 G16 B16 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH49 CH50 CH51 CH52 CH53 CH54 CH55 CH56 CH57 CH58 CH59 CH60 R17 G17 B17 R18 G18 B18 R19 G19 B19 R20 G20 B20 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH61 CH62 CH63 CH64 CH65 CH66 C
4. Signal 3 Pin XLR socket Pin 3 Signal E Pin 1 GND jue Pin 2 Signal Pin 4 N Pin 3 Signal 3 Pin 5 N C 5 Pin XLR socket 3 Pin XLR socket Pin 1 GND orreen Pin 1 GND Pin 2 Signal Pin 2 Signal Pin 3 Signal Pin 3 Signal Pin 4 N Pin 5 N C Special Note Line termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator CABL90 3 pin or CABL89 5 pin will decrease the possibilities of erratic behaviour Notes Notes Correct Disposal of This Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries with seperate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please seperate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local go
5. a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Cleaning must be done at regular intervals Before cleaning wait until the unit has cooled Use a vacuum or dry compressed air and a soft brush to remove the dust collected on the external vents and accessible internal components Clean the external surfaces with a mild solution of non ammonia glass cleaner or isopropyl alcohol and wipe with a soft lint free cotton cloth or lense cleaning tissue Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 100V 240V Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature f your product fails to function correctly discontinue use i
6. 5 B15 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 R16 G16 B16 i G17 B17 i G18 G18 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH73 CH74 CH75 CH76 CH77 CH78 CH79 CH80 CH81 CH82 CH83 CH84 R19 G19 B19 Dimmer R20 G20 B20 Dimmer R21 G21 B21 Dimmer 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 21 0 100 CH85 CH86 CH87 CH88 CH89 CH90 CH91 CH92 CH93 CH94 CH95 CH96 R22 G22 B22 R23 G23 B23 R24 G24 B24 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH97 CH98 CH99 CH100 R25 G25 B25 Dimmer 0 100 0 100 0 100 Rigging NOTE The installation of this unit must be carried out by qualified service personal only Improper installation can result in serious injuries and or damage to the property Overhead rigging requires extensive experience Working load limits should be respected certified installation materials should be used and the installed unit should be inspected regular intervals for safety Before rigging overhead Make sure the area below the installation place is free from unwanted persons during rigging de rigging and servicing Locate the fixture in a well ventilated spot far away from any flammable materials and or liquids The fixture must be fixed at least 50cm from surrounding walls The device should be installed out of reach of people and outside areas where persons may walk by or be seated Bef
7. 5W 26 75 76 78 or 100 channel DMX address information please see pages overleaf 14 Built in programme chart Static colour Blackout red yellow green cyan blue purple white BLAC RGB Flash 00 99 Flash speed adjustable Dream 7 colour dreaming Speed 00 99 Fash 00 99 Speed amp flash adjustable Meteor 7 colour flow Speed 00 99 Flash 00 99 Speed amp flash adjustable Fade 7 colour fade Speed 00 99 Flash 00 99 Speed amp flash adjustable Change 7 colour change Speed 00 99 Flash 00 99 Speed amp flash adjustable Flow 1 7 colour chase Speed 00 99 Flash 00 99 Speed amp flash adjustable Flow 2 7 colour chase Speed 00 99 Flash 00 99 Speed amp flash adjustable Flow 3 7 colour chase Speed 00 99 Flash 00 99 Speed amp flash adjustable Flow 4 7 colour chase Speed 00 99 Flash 00 99 Speed amp flash adjustable Flow 5 7 colour chase Speed 00 99 Flash 00 99 Speed amp flash adjustable Flow 6 7 colour chase Speed 00 99 Flash 00 99 Speed amp flash adjustable Flow 7 7 colour chase Speed 00 99 Flash 00 99 Speed amp flash adjustable Flow 8 7 colour chase C1 RGB C2 RGB Speed amp flash adjustable Flow 9 7 colour chase C1 RGB C2 RGB Speed amp flash adjustable 3 channel mode DMX chart 5 channel mode DMX chart No function 11 255 Strobe slow to fast 6 channel mode DMX chart 0 255 Master dimmer 0 100 2 0 149 Static Pattern 150 255 Moving Pattern slow to fast 0 149 Patern selector 099
8. H67 CH68 CH69 CH70 CH71 CH72 R21 G21 B21 R22 G22 B22 R23 G23 B23 R24 G24 B24 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH73 CH74 CH75 R25 G25 B25 0 100 0 100 0 100 76 channel mode DMX chart R1 G1 B1 R2 G2 B2 R3 G3 B3 R4 G4 B4 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH13 CH14 CH15 CH16 CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24 R5 G5 B5 R6 G6 B6 R7 G7 B7 R8 G8 B8 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH25 CH26 CH27 CH28 CH29 CH30 CH31 CH32 CH33 CH34 CH35 CH36 R9 G9 B9 R10 G10 B10 R11 G11 B11 R12 G12 B12 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH37 CH38 CH39 CH40 CH41 CH42 CH43 CH44 CH45 CH46 CH47 CH48 R13 G13 B13 R14 G14 B14 R15 G15 B15 R16 G16 B16 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH49 CH50 CH51 CH52 CH53 CH54 CH55 CH56 CH57 CH58 CH59 CH60 R17 G17 B17 R18 G18 B18 R19 G19 B19 R20 G20 B20 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH61 CH62 CH63 CH64 CH65 CH66 CH67 CH68 CH69 CH70 CH71 CH72 R21 G21 B21 R22 G22 B22 R23 323 B23 R24 G24 B24 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 0 100 CH73
9. addressable LEDs Fan cooled Quarter turn quick lock rigging system Power consumption 780W Power supply 100 240V 50Hz 60Hz Dimensions 550 x 130 x 550mm Weight 18 5kg Operating modes 1 Sound active 2 Auto 3 Master slave 4 Built in programmes 5 DMX Back view 13 lumen8 TRI PIXEL PANEL 25 11 Cooling fan ES 12 Function buttons e 13 Coffin locks 14 LCD display 11 10 Identification 1 Safety eyes 2 Power in socket 3 Power out socket 12 4 Flying bracket ELUMO85A 5 Fuse F4A 250V F8A 120V 11 6 3 pin XLR in socket 7 3 pin out socket 8 5 pin XLR in socket 9 5 pin XLR out socket 10 Microphone 4 Bracket amp fixings Operation modes Sound Active mode To activate the unit in sound active mode press the MODE button to show SOUND MODE on the LCD screen Now press the SET UP button to select the desired sensitivity level by using the UP and DOWN buttons Press the SET UP button again to select the frequency level and adjust by using the UP and DOWN buttons SENS 00 31 00 low 31 high FQN 01 99 01 low 99 high Auto run mode To activate the unit in auto run mode press the MODE button to show AUTO RUN on the LCD screen Now press the SET UP button to select the desired frequency level by using the UP and DOWN buttons FQN 01 99 01 low 99 high Note In thi
10. he Tri Pixel Panel 25 To attach the flying bracket first you must remove the supplied hanging bracket from the unit To do this simply unscrew the tightening knobs on the side of the unit and slide off On the top of the flying bracket there is 2 clamp points M12 Please use these to attach suitable clamps before fitting to the unit Place the flying bracket on top of the unit making sure that both carry handles are folded flat Line up the bracket with the steel locating pins Now using a size 8 allen key turn the coffin lock and turn anti clockwise until you hear it lock into position Make sure that you hear a click and cannot turn the lock any more Fix 2 suitable safety cable s to the safety eyes to make sure the unit cannot drop more than 20cm if the hanging bracket or clamps fail Lumen8 TRI PIXEL PANEL 25 www prolight co uk TRI PIXEL PANEL 25 www prolight co uk If you cannot lock the bracket as described please check that it is in the correct position before attempting to join the units Turn the lock clockwise until the pin is in the correct position see below Multi array set up Once the flying bracket has been fixed to the unit securely you can add a maximum of 4 units horizontally for the array and vertically you can fix as many columns as you like each column must feature an array bracket at the top NOTE Please be sure that each unit is fixed together properly using the coffin locks on the lef
11. mmediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS WARRANTY One year from date of purchase LEDJ products are designed and intended for professional use only by competant persons The products are not suitable for domestic use OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks LED failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property Overview You should find inside the elumen carton the following items 1 Tri Pixel Panel 25 2 Instruction manual 3 Power Cable Technical Specifications 25 x 30W tri colour LEDs Beam angle 80 degrees 1100Hz refresh rate e 0 100 dimming and variable strobe DMX channels 3 5 6 25C 25W 26 75 76 78 or 100 selectable Sound active auto master slave built in programmes and DMX modes 4 push button menu with LCD display Powercon in out sockets 3 Pin XLR in out sockets 5 pin XLR in out sockets Individually
12. ns can be managed remotely DMX start address The DMX start addres can be set remotely from 001 to 512 DMX personality Set the DMX personality mode remotely The two above functions make it possible to prepare a complete DMX patch of all units on the DMX controller and sends this data to all of the units at once DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is l
13. ocated in the DMX chain DATA Cable DMX cable requirements for DMX operation The Tri Pixel Panel 25 can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 or 5 pin XLR connector for data input output figure 1 Figure 1 Also remember that DMX cable must be daisy chained and cannot be split Notice Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX S12 out Tiss 9T DMX SI2 in XLR Pin Configuration XLR Pin Configuration 12002 ea siad Pin 1 Ground Pin 1 Ground fo Pin 2 Negative Pin 2 Negative DMX 512 out os 10 for 5Q DMX 512 in ae Na o Pin 3 Postive Pin 3 Postive FIGURE 3 Pin 4 Not used Pin 5 Not used FIGURE 2 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion 5 Pin XLR socket Pin 1 GND jorreen Pin 2
14. ore rigging make sure that the installation area can hold a minimum point load of 10 times the device s weight Always use a certified safety cable that can hold 12 times the weight of the device when installing the unit This secondary safety attachment should be installed in a way that no part of the installation can drop more than 20cm if the main attachment fails The device should be well fixed a free swinging mounting is dangerous and should not be used Don t cover any ventilation openings as this may result in overheating Rigging with supplied hanging Bracket The supplied hanging bracket can be used to place the unit on the floor and point it in a desired direction In this case a proper and stable base should be used The hanging bracket can also be used to hang the unit on truss and point it in the desired direction Fix 2 suitable truss clamps to the holes in the hanging bracket Make sure that both clamps are firmly fixed to the bracket tight and secure Fix 1 or 2 suitable safety cable s to the safety eyes to make sure the unit cannot drop more than 20cm if the hanging bracket or clamps fail Truss Safety wire NOTE Using the supplied hanging bracket you CANNOT fix more than one unit together If you want to hang and array of units you must use the optional heavy Tri Pixel Panel 25 Flying bracket ELUMO85A Rigging with optional Flying Brocket ELUMO85A This flying bracket is used for hanging arrays of t
15. s mode it will run 14 built in programmes in a continuous loop Slave mode To activate the unit in slave mode first you must link multiple units together and press the MODE button to show SLAVE MODE on the LCD screen Now on the master unit press the MODE button to select the desired mode and the slave units will now run in sequence with the master unit Built in programmes To activate the units built in programmes press the MODE button to show 01 STATIC on the LCD screen Press the SET UP button to choose between the 14 built in programmes by using the UP and DOWN buttons Now press the SET UP button to select the desired speed and adjust by using the UP and DOWN buttons Press the SET UP button once more to select the desired flash value and adjust by using the UP and DOWN buttons Speed values 00 99 00 slow 99 fast Flash values 00 99 00 slow 99 fast For the 14 built in programmes please see page 5 DMX mode To activate the unit in DMX mode press the MODE button to show DMX MODE on the LCD screen Press the SET UP button and select the desired DMX address setting by using the UP and DOWN buttons Then to select one of the DMX modes 3 5 6 25C 25W 26 75 76 78 or 100 channel press the SET UP button again to choose the desired DMX mode by using the UP and DOWN buttons For the 3 5 6 25C 2
16. t side and bottom side of the unit following the same method for the flying bracket Safety Wire Safety Wire Safety Wire Safety Wire Safety Wire When the units are lined up against each other use a size 8 allen key to turn the coffin lock turn the coffin lock anti clockwise until you hear it lock into position Make sure that you hear a click and cannot turn the lock any more RDM functions and remote setup means Remote Device Management The Tri Pixel Panel 25 works with a brief set of functions that means it can setup a bidirectional communication with an RDM compatible DMX controller See below for a brief of some of these functions more will be added in the future The DMX controller will send out a discovery command the unit s respond and send their unique unit ID The DMX controller asks each RDM unit for basic data so it knows which unit s are connected The Elumene8 Tri Pixel Panel 25 will show Unit name Tri Pixel Panel 25 e Manufacturer Elumen8 Category LED Dimmer Fiimware XXXX version of the software of the unit e DMX address XXX current DMX start address of the unit DMX footprint XX current number of DMX channels used by the unit Personality XX current working DMX mode personality of the unit The DMX controller can send certain commands to each to each RDM unit which allows remote setup of the units The following functio
17. vernment office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for CEL amp C9 Lumen8 www prolight co uk
Download Pdf Manuals