1. Fixed Ratio Training Cancel Figure 3 3 Header Details For New Protocol Window When the three settings are complete click on the OK button and the new blank protocol is created and added to the Protocols list K Limbic Developers Guide Tutorial Guide 17 Edit The Protocol Select the new protocol in the Protocols list and click on the Edit Protocol button this opens the Protocol Editor shown in figure 3 5 Protocol Header Modified Protocol Header Title Fixed Ratio Protocol Description Fixed Ratio Training Stage Qutput Reports Report List Empty p Required Parameters No Database Parameters Required Figure 3 5 Protocol Editor Window The Protocol Editor displays the new protocol as yet there is not much to display The left hand section accesses editors for the various protocol components the right hand section displays the current contents of each component of the protocol The procedure for creating editing a protocol is to select each component in turn and make the appropriate settings The components are as follows The Header Component the Reference Title amp Description of the protocol The Resources component the items required in the operant chamber The Stages component a list of stages for the experiment The Endpoints component a list of endpoint conditions The Process component the flow betw
2. Group and Profile names in that order With the Selected Lever entry selected in the parameters list click on the Tag button an arrow will appear next to the Selected Lever parameters showing that it is currently tagged successive clicking on the Tag button toggles the tag on and off Click on the OK button to return to the Copy Tagged Parameters window Click on the Select Subjects button this presents the Select Subjects window kK Limbic Developers Guide Tutorial Guide 49 We want to select half the subjects in the database so that the levers are used equally in each box the way to do this depends on how many boxes are used in the system The table below assumes that the system consists of 8 boxes and that subjects are used sequentially i e animals 1 8 go in boxes 1 8 animals 9 16 go in boxes 1 8 etc Subjects Target Lever 1 4 Left 5 12 Right 13 20 Left 21 28 Right 29 36 Left 37 44 Right 45 52 Left 53 60 Right 61 64 Left We want to change all subjects who should be assigned the right lever as the target therefore select subjects 5 12 21 28 37 44 amp 53 60 To select a subject highlight it in the Available list and click on the Select gt gt button the subject moves over to the Selected list repeat this for all the required subjects When all required subjects are selected click on the OK button Click on the Apply Tagged P
3. All data generated to date is discarded 3 10 What Happens At The End Of A Session A session ends when all the protocols in the session are complete At the end of the session the data generated for each box is formatted and stored in the data directory for the session A separate file is created each time a session is run A report will appear on screen as the files are being formatted if no problems are encountered during formatting then this report is removed if a problem is encountered then an error status message is presented Please note the fixed ratio session as defined here does not generate any data The normal situation is that no errors occur and the Session Complete information window appears on the screen Click OK to remove this window To run another session From the K Limbic main menu select Session Close Session This will close the run time display and return to the main screen then From the K Limbic main menu select Session Load Session Repeat the load session process outlined above kK Limbic Developers Guide Tutorial Guide 59 3 11 Where Now If you have worked through the fixed ratio protocol example and tested that your final installed test suite and session runs a successful fixed ratio protocol then you are ready to start writing your own protocols The procedure of creating any protocol is the same as for the fixed ratio protocol configure each of the protocol component
4. The sequential choice auto control is intended for use in sequential choice tests using a five choice chamber Edit Sequential Choice Parameters Sequence Type Cancel 1 Sample 2 From 5 Normalised OK Targets Iterations Nose Poke 1 Nose Poke 2 Nose Poke 3 25 Nose Poke 4 Nose Poke 5 V Banked Total Trials 100 Figure 4 12 Sequential Choice Parameters A sequential choice control contains the following settings Sequence Type List of sequence options Targets List of available targets levers sensors or nose pokes Iterations Number of trial groups Banking Enable disable banking The control produces a table of trial settings used to control a sequential choice experiment There are two available options for the sequence 1 Sample 2 from 5 Normalised 2 Sample 3 from 5 Normalised Sequence 1 is used to present a sequence of 2 cue lights followed by presenting both lights together to gain a reward the subject must respond on the light presented first Sequence 2 is used to present a sequence of 3 cue lights followed by presenting two of the three lights together to gain a reward the subject must respond on the light presented first The sequences are split into groups In sequence 1 each group has the same distance between the lights i e 1 2 3 or 4 resulting in 4 groups and a bank size or 4 In sequence 2 each group has the same combination of lag
5. The timing of the intervals is subject to several control options e Wait For Target Initial If enabled then the timing of the first interval does not start until the subject activates the target resource e Reset On Target If enabled then the timer of the current interval is reset when the subject activates the target resource e Reset On Dummy If enabled then the timer of the current interval is reset when the subject activates the dummy resource e Exit On Target Trigger an endpoint when the subject activates the target resource e Exit On Dummy Trigger an endpoint when the subject activates the target resource An interval is marked as active if the subject activates the target resource during the interval otherwise the interval is considered inactive Active and inactive intervals have the additional controls e Trigger On Interval e Wait For Target If Trigger On Interval is selected then the interval trigger endpoint occurs immediately the interval timeout occurs if Wait For Target is selected then the interval trigger endpoint occurs on the first activation of the target resource after the interval timeout Interval stage also include the following controls e On Stage Exit Reset Timer Control e On New Trial Reset Auto Control If Reset Timer Control is enabled then whenever the protocol leaves the stage the interval timer is reset so on the next entry to
6. Components e Driver Controls Display Message Cue Light States Target Dummy Settings Stage Exit Triggers Stage Reports Function Cued Choice stages are designed for protocols running in chambers with nose poke niches e g a five choice chamber Cued Choice stages were originally designed for use in protocols that run the DMTP paradigm in a five choice chamber The DMTP protocol is essentially the same as the lever based DMTP protocol however Cued Choice stages should be used for the Present Sample and Choice stages A Cued Choice Stage sets the state of the operant chamber then waits for a response or a timeout The Target Dummy settings are extracted from the DMTP auto control define two or more Nosepoke resources instead of the left amp right levers in the Standard and Reverse target lists Cued Choice stages always reset the stage timer on entry therefore they can be re entered many times in the same trial and will always last for the full timeout period For an example of the use of Cued Choice stages refer to the K Limbic repository k Limbic Developers Guide Stage Type Reference 108 5 2 20 Sequential Choice Stage Components Driver Controls Display Message Target Dummy Settings Stage Exit Triggers Stage Reports Function Sequential Choice stages are designed for protocols running in chambers with nose poke niches e g a five choice cham
7. Reverse Auto then the Standard Target from the DMTP control for the current trial will be assigned as the Target resource If the Dummy assignment in any stage is set to Reverse Auto then the Reverse Target from the DMTP control for the current trial will be assigned as the Dummy resource In Non Match To Position mode If the Target assignment in any stage is set to Reverse Auto then the Reverse Target from the DMTP control for the current trial will be assigned as the Target resource If the Dummy assignment in any stage is set to Reverse Auto then the Standard Target from the DMTP control for the current trial will be assigned as the Dummy resource To create the Sample Lever amp Lever Choice stages in a DMTP protocol use the following Target Dummy assignments Sample Lever Stage Target Assignment Standard Auto Dummy Assignment None Lever Choice Stage Target Assignment Reverse Auto Dummy Assignment Reverse Auto Using the above Target Dummy assignments it is possible to create a DMTP protocol that can be used for both DMTP amp DNMTP tasks the style of task being dependent on the settings in the subject database kK Limbic Developers Guide Auto Control Reference 79 4 12 The Sequential Choice Auto Control A sequential choice auto control is built using sequential choice parameters from the subject database
8. options The fixed ratio protocol requires the subject to make multiple responses on the target lever to obtain rewards however you will note that at no stage in the protocol do we make any assignment for the target lever so how does the system know what which lever to use Fixed ratio stages know that a target is required and perhaps a dummy too however they also know that they need to extract this information from the subject database from the FR Parameters therefore as the session is loaded the protocol manager extracts the FR Parameters from the database and sets the appropriate sensor as the target K Limbic Developers Guide Tutorial Guide FR Complete Protocol Endpoint Timeout Notes Fixed ratio schedule set by database Protocol Timeout value set by database Figure 3 4 Fixed Ratio Protocol Flowchart kK Limbic Developers Guide Tutorial Guide 16 Create The Protocol Click on the New Protocol button this will present the Header Details For New Protocol window Enter details into the Reference Title amp Descriptions fields suitable entries are illustrated in figure 3 3 the Reference entry should be unique the Title amp Description entries can be any values header values can be changed at any time so the precise entries are unimportant at this stage Header Details For New Protocol Header Details Reference 240300 Title Fixed Ratio Protocol Description
9. window Configuring Resources Please note that the resources defined in the protocol do not specify the interface channel that the resource is attached to When the protocol is loaded prior to running a session each resource in the resource list is compared with the resource list configured for the particular system the channel assignments from the configured list are then used for the resources in the protocol i e the first resource in our list is Lever Control lt 1 gt the configured resource list is searched for a resource of type Lever Control lt 1 gt the resource description field is ignored when found the channel assignment for this resource is copied into the protocol If no resource is found in the configured list then a warning message is issued and the session aborted Using this technique the same protocol can be used on different systems regardless of the manner in which the resources are attached kK Limbic Developers Guide Tutorial Guide 20 The Stages Component We discussed the protocol flowchart a little earlier and determined that the fixed ratio protocol consists of six stages we need to add these stages to the stages component and edit them so that they act as required Click on the icon labelled Stages the right hand side displays the current list of stages Unsurprisingly the stage list is initially empty Click on the Edit Stages button the Configure Stages window displays Th
10. Import Profile Assign 4s Current Operant User C Program Files Conclusive KLimbic System f0107D50011B ksr Figure 3 1 Profile Manager Window kK Limbic Developers Guide Tutorial Guide 11 The default user contains two profiles Operant and Five Choice the appropriate profile for the fixed ratio protocol is the Operant profile select the Operant entry in the Profiles list and click on the Assign As Current button the Operant profile will be marked as Current Click on the Quit button to close the Profile Manager window This completes the check of the user profile K Limbic Developers Guide Tutorial Guide 12 3 2 Create Your New Protocol Protocols are created edited and managed using the Protocol Manager From the K Limbic main menu select Protocols Protocol Manager or press function key F3 This will present the Protocol Manager window Protocol Manager Protocols 240200TT CER Protocol Test Conditioned Emotional Response 240154 CRF Training Continuous Reinforcement Training With ITI 240600 Timed Pellet Delivery Timed Pellet Delivery Protocol 240601 Timed Pellet Delivery Timed Pellet Delivery Protocol With Magazine Light 240400 Conflict Task Geller Seifter Conflict Test Conflict FR Training FR Training For Conflict Progressive Ratio Protocol Progressive Ratio Protocol Progressive Ratio Protocol Progressive Ratio Protocol
11. and distance between the lights resulting in 8 groups and a bank size of 8 kK Limbic Developers Guide Auto Control Reference 80 The settings of the sequential choice auto control are used by stages of type Sequential Choice refer to the K Limbic repository for a full discussion of the sequential choice test kK Limbic Developers Guide Auto Control Reference 81 4 13 The Cued Lever Auto Control A Cued Lever auto control is built using cued lever reversal parameters from the subject database The Cued Lever auto control is intended for use in cued lever serial reversal tests using a skinner box with two levers and two cue lights The settings of the cued lever auto control are accessed from Cued Lever stages in the protocol Edit Cued Lever Parameters Task Control Cue Control OK Vary By Trial Standard C None C Vary By Session C Reverse C Both Sequence Control Target Sequence C Select At Run Time Right C Random Right C Auto Increment 3 P Right Left CL Sequence 1 v Righ Left C Both Levers Active Right Right Left Right Valid Sequences Left Preset Sequence Use Sequences 1 5 C Use Sequences 1 12 Reset Sequence Figure 4 13 Cued Lever Reversal Parameters The Cued Lever test Serial Reversal protocol is available in the K Limbic repository refer to the protocol description document for a full discussion of the protocol I
12. 0 2n 5 Reward On Dummy Breakpoints Idle Timeout V No Reward Breakpoint Hours Mins Secs Hours Mins Secs sio foo foo si fs foo Cancel Figure 4 10 Progressive Ratio Parameters A progressive ratio control contains the following settings Progression The sequence of increasing ratios Enable Reset Reset the count if a response is made on the Dummy Reward On Dummy Treat The Dummy as if it were a Target Idle Timeout Enable Enable the idle timeout Idle Timeout The idle timeout value No Reward Breakpoint Enable Enable the no reward timeout No Reward Breakpoint The no reward timeout value The target ratio for the progressive ratio stage increases on each iteration through the stage The ratio increases according to the selected progression type examples of the available progressions are listed below kK Limbic Developers Guide Auto Control Reference 75 Available Progressions There are a number of options that can be selected for the progression 1 F n 5 x EXP 0 2n 5 Example sequence 1 2 4 6 9 12 15 20 25 32 40 50 62 77 95 118 145 178 219 268 etc 2 Option 1 Example sequence 1 2 3 4 5 6 7 8 10 12 14 16 18 20 22 24 28 32 36 40 44 48 52 56 64 72 80 88 96 104 etc 3 Option 2 Example sequence 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 70 80 90 100 110 130 150 170 190 210 230 250 270 290 310 etc 4 Constant 10 This option uses
13. 26 Location Stage Components Driver Controls Display Message Stage Exit Triggers Target Position Stage Reports Function A Location stage is provided to monitor the current location of a subject Location stages are useful in protocols that are required to monitor and or react to the position of a subject within an environment An example of monitoring the position of a subject would be a Passive Avoidance test A Passive Avoidance test environment is split into light and dark chambers separated by a door The subject is placed into the light chamber with the door closed The door opens at the start of the test and system monitors the time it takes the animal to cross into the dark chamber Position sensors monitor the current location of the subject light beams are often used as position sensors In alocation stage the developer defines a target position by specifying a desired state for each position sensor When the subject moves to the location that provides the desired combination of states the stage triggers the Exit On Target Position endpoint A position sensor may be e Active e Inactive e Don t Care A position sensor is Active when the sensor detects the presence of the subject A position sensor is Inactive when the sensor does not detect the presence of the subject A location stage can also trigger an endpoint when any of the position sensors c
14. Controls e Display Message e Stage Exit Triggers Function A Serial Choice Timeout stage is specifically designed to perform the Timeout function in the five choice serial reaction time task The stage sets the state of the operant chamber normally just the house light then waits for a response in any sensor or for the stage timeout to occur The Serial Choice Timeout stage inherits the target dummy assignments of the serial choice stage that precedes it in the stage list either a Serial Choice Inter Trial Interval stage or a Serial Choice Collection stage the Reset Timeout option causes the stage to reset its timeout if a response on any dummy resource is made i e repeated premature or perseverative responses The Exit On Target amp Exit On Dummy endpoints are usually disabled The developer normally assigns the timeout stage as a resetting 5 second timeout where the subject is required to do nothing for a minimum of 5 seconds in order for the protocol to progress to the next stage k Limbic Developers Guide Stage Type Reference 102 5 2 15 Serial Choice Training Stage Components Driver Controls Display Message Target Position Stage Exit Triggers Stage Reports Function A Serial Choice Training stage is specifically designed to assist the developer in defining five choice training protocols The stage sets the state of the op
15. Controls the number of trials Banking Controls the banking of trials Inter Trial Interval Duration of the ITI stage Tone Parameters Tone Burst Duration of the distraction tone burst Tone Timing Timing of the distraction tone burst Has no effect when using Med Associates hardware Edit Serial Choice Parameters Comment MV Automatic Comment Stimulus Parameters Duration Intensity Limited Hold 1 005 H 100 H 10 05 Stimulus Parameters Control Parameters Tone Parameters Cancel Figure 4 6 One Choice Stimulus Parameters kK Limbic Developers Guide Auto Control Reference 69 The number of trials generated depends on the Iterations setting and the mode of the table In Table mode the operator selects one entry from the table all trials in the session are built using the values held in this one entry The number of trials is calculated as Trials 1 Stimulus light x Iterations e g To generate a session with 100 trials set the Iterations parameter to 100 In Series mode the trials in the session are built using all values in the table The number of trials is calculated as Trials 1 Stimulus Light x Iterations x Entries e g With a table with 5 entries to generate a session with 100 trials set the Iterations parameter to 20 The one choice table auto control is used by the Serial Choice stages held in a protocol in the same fashion as a five choice table auto control is used For a full discu
16. Limbic Developers Guide Tutorial Guide 23 Step 7 of 7 Stage Reports The Stage Reports section allows the developer control over whether or not the stage generates any reports to send to the output file In this example protocol we will enable some output reports without being overly concerned with detailed analysis of results Check the Enable Reports option to enable the rest of the options Check the following options Stage Entry The entry time of this stage Stage Exit The exit time of this stage Target ID The identifier of the target lever Target Count The number of responses on the lever during the stage Counts Sensors The number of nose pokes into the pellet receptacle Target Ratio The fixed ratio schedule Click on the Finish button at the bottom of the window The fixed ratio stage will generate each of these reports at the end of each trial i e once per iteration through the protocol They will appear in the output file as a row of data items The settings for the fixed ratio stage are complete so the wizard closes and the new stage is added to the Configured Stages list Note that we have not specified which lever is the target lever for this stage This is because the protocol manager knows that it has to interrogate the subject database for this information Using this approach the assignment of target lever and fixed ratio value become subject dependent Add the Dispense Rewa
17. Limbic provides utilities for creating and maintaining databases It is advisable to become familiar with the operation and maintenance of databases before using the system in a live study All subjects in a database contain the following items e A Rewards Table e A Dosing List e A Parameters List The Rewards Table stores a list of entries appropriate for delivering rewards and ironically shocks The table entries define a series of pulses or triggers In the case of a protocol that only uses a pellet dispenser this table only requires a single entry defining a pulse long enough to trigger the pellet dispenser the duration of the pulse required varies depending on the manufacturer of the pellet dispenser but 100mS is a typical pulse duration Protocols that deliver foot shocks as well as pellets will need two entries in the rewards table one to define the pellet delivery pulse and one to specify the duration of the foot shock If alternative methods of reward delivery are used such as syringe pumps or fluid dippers the pulse duration will need to be determined by experimentation The Dosing List defines a list of doses that will be given to the subject during any given study The operator selects the appropriate dose from the dosing list during the process of loading a session prior to running an experiment The dose details appear in the output data file and can be included in the data analysis worksheets Using suitable dosi
18. S n identifies that sensor S n was activated the index n is zero based thus sensor lt 1 gt is reported as S 0 sensor lt 2 gt is reported as S 1 etc The activation time was 76 85 seconds after the start of the session Response Released Report generated each time a sensor is released 2003 OFF 1 S 0 8055 The value 1 is the index of the current stage The index is zero based thus stage 1 is reported as 0 stage 2 is reported as 1 etc S n identifies that sensor S n was released the index n is zero based thus sensor lt 1 gt is reported as S 0 sensor lt 2 gt is reported as S 1 etc The release time was 80 55 seconds after the start of the session kK Limbic Developers Guide Output File Format 120 Please note that if the message filter is enabled Response Released activity reports will not be generated Stage Entry Report generated whenever a stage is entered 2004 STIN 4 8877 The value 4 is the index of the new stage The index is zero based thus stage 1 is reported as 0 stage 2 is reported as 1 etc Here stage 5 was entered 88 77 seconds after the start of the session Stage Exit Report generated by the end of a stage 2005 STOUT 3 9866 2 The value 3 is the index of the current stage The index is zero based thus stage 1 is reported as 0 stage 2 is reported as 1 etc Here stage 4 was exited 98 66 seconds after the start of the session The end of the stage was trigger
19. To Start Ready To Start Left Lever Press 0 Right Lever Press O Pellet Dispenser 0 Shock Control 0 Magazine Sensor 0 m Responses m Rewards Session Training Session The Session Has Loaded Successfully And Is Now Ready To Run a Subiect Doss Status Trials Left Lever Press Right Lever Press Magazine Sensor Pellet Dispenser Shock Cont 1 Ready To Start 0 Q 0 0 0 0 Ready To Start 3 Ready To Start 4 Ready To Start 5 Ready To Start 6 Ready To Start z Ready To Start 8 Ready To Start Operant Profile ES k Limbic Figure 3 30 Run Time Session Screen At the top there is a tabbed section 1 tab per box this section displays subject and protocol information At the bottom there is a summary section 1 row per box so that all boxes are visible at once On the right hand side is the Run Manager window The Run Manager provides controls for starting and stopping the session Start The Session The most common function is to start all boxes running in one operation click on the Run All button in the Run Manager The display will update to show that all boxes are now running there is a slight delay between each box starting this is deliberate Alternatively it is possible to start boxes individually select the required box in the list in the Run Manager and click on the Run button kK Limbic Developers Guide Tutorial Guide 58
20. Window When the Run List is complete click on the OK button to return to the Configure Session window Back in the Configure Session window Set the Display Type to a suitable value there is a specific display for fixed ratio protocols select the Fixed Ratio Display Auto Control Mode should remain as Use Subject Parameters Enable Dose List should be checked Enable Event Log should be unchecked Enable Shocks should be checked although no shocks are delivered during the protocol This completes the configuration of the Fixed Ratio Session click on the OK button to return to the Configure Test Suite window This completes the configuration of the Fixed Ratio 101 Development Test Suite Click on the OK button to return to the Test Suite Manager Click on the Exit button to return to the K Limbic main screen This automatically saves the configuration of the Fixed Ratio 101 Test Suite kK Limbic Developers Guide Tutorial Guide 43 3 4 Build An Installed Test Suite Test Suites are created edited and managed using the Test Suite Manager From the K Limbic main menu select Test Suites Test Suite Manager or press function key F4 This will present the Test Suite Manager window Under the Development Test Suite tab select the Fixed Ratio 101 Development Test Suite We have previously configured this test suite n
21. a flash of a cue light in one of the niches The stimulus parameters are controlled by the auto control which in turn is determined by settings in the five choice parameters of the subject database The stage pauses for a response in one of the niches correct or incorrect or for the stage timeout to occur The stage timeout is called the Limited Hold period The Limited Hold period is specified using the Limited Hold setting of the five choice parameters of the subject database Stimulus presentation is a special function of the serial choice present stimulus stage Presentation of the stimulus is automatic The developer is not concerned with defining the stimulus when developing the protocol The subject database and auto control deal with the stimulus presentation The Serial Choice Present Stimulus stage always resets the stage timer on entry therefore it can be re entered many times in the same trial and will always last for the full Limited Hold period however the standard five choice paradigm assumes that one stimulus occurs per trial The Serial Choice Present Stimulus stage automatically assigns the niche in which the stimulus occurred as the target resource all remaining nosepoke sensors are automatically assigned as dummy resources A response in the correct niche triggers the Exit On Target endpoint a response in any incorrect niches triggers the Exit On Dumm
22. a five choice chamber should be assigned as class Varilux Driver In general any sensors in the chamber should be assigned as class Sensor however K Limbic Developers Guide Tutorial Guide 19 any sensors which are attached to K Limbic via an NC 9 controller when using Diplomat hardware from Conclusive should be assigned the class NC 9 Sensor Leave the class of the lever control as Driver Click on the OK button to close the Edit Resource window To add a new resource to the list select the required resource type in the Available Resources list and click on the Add Resource button a new resource of the chosen type will be added to the list For example to add a light to the list select the Light entry in the Available Resources list and click on the Add Resource button The Configured Resources list will update with the new entry Light lt 3 gt indicating that it is the third light in the list of configured resources Click on the Edit Resource button to modify the description for this resource to something meaningful To delete an unwanted resource from the list select the resource in the Configured Resources list and click on the Delete Resource button the resource will be deleted For the purposes of this example modify the resource list if required so that it is the same as shown in figure 3 5 above and close the Configure Resources
23. banking is enabled then peak trials are evenly distributed throughout the test if banking is disabled then the distribution of peak trials is fully random Refer to the K Limbic repository for a discussion of the DRL test kK Limbic Developers Guide Auto Control Reference 84 4 15 The CER Auto Control Conditioned Emotional Response A CER auto control is built using a CER parameter from the subject database CER parameters are available in the database under the following parameter types e CER Table e CER Parameter A CER table is always used in Table mode i e the operator selects one entry from the table for use in the current session The CER parameters are intended for use in CER tests Refer to the K Limbic repository for a full discussion of the CER test Edit CER Parameters Comment Training Level 2 CER Details V Enable Shocks Group 4 Edit Vl Parameters MV Enable Shocks Group B V Enable Tones l Enable Cue Lights OK Cancel Figure 4 14 CER Parameters As illustrated in fig 4 14 the CER parameters are a combination of standard VI parameters a variable auto timeout and four enabling controls The VI parameters generate a standard list of variable intervals see section 4 2 for a discussion He variable interval values are accessed as the interval value during VI stages The Timeout value can be either a set period or as with a random variable interval a val
24. fig 4 11 for an example DMTP control using two levers and six values of delay Iterations In the DMTP control an iteration consists of a group of trials In each group a trial is defined in which each sample lever is associated with each delay value for example the DMTP control in fig 4 11 uses 2 levers and 6 delay values therefore each iteration contains 12 trials Using an Iterations value of 8 therefore produces a total of 96 trials in the control Banking If banking is enabled then the trials are randomised within each group but presented as a group of trials i e the first 12 trials will contain one trial where each sample lever is associated with each delay the same is true of the next group of 12 trials etc If banking is disabled then the organisation of trials is fully random Using banking prevents the situation where consecutive trials present the same combination of sample lever amp delay Matching Mode The matching mode has two options Match To Position The Standard lever is the correct lever in the Choice stage Non Match To Position The Reverse lever is the correct lever in the Choice stage Repeat Incorrect Trials If enabled any incorrect trials detected during the test are repeated Repeat Missed Trials If enabled any missed trials detected during the test are repeated The controls to repeat trials are useful during training to correct subj
25. labelled Endpoints the right hand side displays the current list of endpoints Unsurprisingly the endpoints list is initially empty Click on the Edit Endpoints button the Configure Endpoints window displays The Configure Endpoints window is used to add delete and edit the endpoints of the protocol Configure Endpoints Endpoint Details 7 Counts Database Dependent i No Editable Parameters Timeout Database Dependent No Editable Parameters Add Endpoint OK Cancel Figure 3 8 The Configure Endpoints Window There are a number of endpoint triggers available each is available as a table if you define an endpoint table that has more than one value for example a timeout table with three entries the protocol manager will prompt the operator with the table during the load session procedure The operator selects the endpoint entry appropriate for the current session To make the protocol as generic as possible we will add database dependent endpoint entries This instructs the protocol manager to interrogate the subject database for suitable entries from which to set the endpoint values We will add Timeout amp Counts entries in the endpoints table kK Limbic Developers Guide Tutorial Guide 27 Add the endpoints Click on the Add Endpoint Table button In the Select Endpoint Type list select Timeout Database Dependent Click on the OK button The endpoint en
26. on the OK button and the test suite list updates to display the new Test Suite K Limbic Developers Guide Tutorial Guide 33 Launch The Configure Test Suite Window Select the new FR 101 test suite and click on the Edit Test Suite button this presents the Configure Test Suite window with the FR 101 Test Suite loaded Configure Test Suite Fixed Ratio 101 Details Title Fixed Ratio Test Suite Description D evelopment Test Suite Database Configure Database Template Sessions Fixed Ratio Session Operant User Operant Figure 3 11 Configure Test Suite Header Window Figure 3 11 illustrates the state of the test suite after the sessions have been configured The items we need to configure are e The Database Template e The Sessions The Database Template Explained The Database Template will assist us when we need to populate the subject database the list of animals we will use for the experiments The Database Template should contain all the database parameters necessary to run the fixed ratio protocol The database template is used when we populate the subject database later on Each time a new subject is added to the database the contents of the database template are copied into the new subject The new subject contains its own independent set of values so any changes to the subjects details will not affect the template and a change to the template will not ch
27. repository Edit Serial Choice Parameters Comment MV Automatic Comment Tone Parameters Tone Burst Tone Timing i G off 500ms Pte O t 1 2 C tal Stimulus Parameters Control Parameters Tone Parameters Figure 4 7 2 Five Choice Tone Parameters kK Limbic Developers Guide Auto Control Reference 72 4 8 The T Maze Constant Auto Control A T Maze Constant auto control is built using an Iterations parameter and Delay Table from the subject database The T Maze Constant auto control generates a list of trials Each trial in the list assigns a Standard target Reverse target Standard dummy Reverse dummy and an auto timeout The number of trials generated is determined by the value of the Iterations parameter one trial per iteration The operator selects one entry from the delay table for each subject the delay value is used as the auto timeout value for all trials The T Maze Constant auto control is intended for use in T Maze tests where the choice of direction determines the difference between a correct and incorrect trial in this case the correct choice of direction is always the same The protocol must define resources of type Sensor lt 1 gt amp Sensor lt 2 gt we have assumed here the Sensor lt 1 gt detects a Left choice and Sensor lt 2 gt detects a Right choice Standard Target Left Sensor lt 1 gt Reverse Target Right Sensor lt 2 gt Standar
28. the current target is of type Sensor lt 1 gt then Pellet Dispenser lt 1 gt will be considered the Target dispenser An example of this is in maze tests where you wish to deliver a pellet into the target receptacle prior to the start of a trial The Dispense If Target option allows a single reward stage to deliver a pellet into the current target receptacle regardless of the target setting for the current trial A shock control may be disabled unconditionally enabled or conditionally enabled Conditional enables separate the shocks into one of two groups A amp B the auto control and or session controls can be used to enable disable shocks in these groups The duration of the reward and shock pulses is governed by entries in the Rewards Table of the database The reward stage specifies which list of rewards from the rewards table is applicable to each reinforcer k Limbic Developers Guide Stage Type Reference 92 5 2 5 Mark Trial Set Outcome Components e Trial Marker Actions e Display Message Function A Mark Trial Set Outcome stage is a protocol management stage The stage is used to mark the outcome of a trial e g Correct Incorrect Missed etc and or instruct the protocol manager to increment the trial pointer repeat the last trial or mark a trial as incomplete A Mark Trial Set Outcome stage is instantaneous although there is a finite time taken to process
29. 1 gt Right Cue Light Cue Light lt 2 gt House Light Light lt 1 gt ae i Magazine Light Light lt 2 gt Import Resources Pellet Dispenser Pellet Dispenser lt 1 gt Foot Shock Trigger Shock Control lt 1 gt Tone Tone Generator lt 1 gt Left Lever Press Lever Press lt 1 gt Right Lever Press Lever Press lt 2 gt Magazine Sensor Sensor lt 1 gt Export Resources Delete Control Figure 3 25 Display Chamber Resources Window Check that each resource defined in the protocol has a corresponding entry in the Display Chamber Resources window An example is shown in figure 3 25 If you a session defines a resource that is not present in the chamber definition the protocol manager will not be able to assign a channel to the missing resource this will cause the load session operation to abort and report error 202 Unconfigured Resource If you see this error when loading your session please check the chamber definition carefully to determine which resource is missing kK Limbic Developers Guide Tutorial Guide 54 3 7 How To Load amp Run A K Limbic Session Once the sessions in a test suite have been fully configured the system is ready to run experiments unless your requirements change you will not need to reconfigure anything in the test suite The procedure to load and run sessions is quick and simple 1 Load the Test Suite 2 Load the Session 3 Run the Sessi
30. 2 5 2 24 DRL Stage Components e Driver Controls e Display Message e Target Dummy Settings e Stage Exit Triggers e Stage Reports Function A DRL stage is specifically designed to cater for the DRL delayed reinforcement protocol The stage sets the state of the operant chamber then waits for a response or a timeout On entry the DRL stage enters a delay phase any response on the target resource during the delay phase is considered an incorrect response The stage provides an incorrect response endpoint so that the stage may exit when an incorrect response is made The duration of the delay is determined by the DRL auto control At the end of the delay phase the stage enters a waiting for response phase The waiting phase lasts from the end of the delay until the stage timeout The stage timeout is set either as a fixed timeout or via the DRL parameters of the subject database The subject must learn to delay any response to the lever for the duration of the Delay period in order to obtain a reward A fully trained subject would operate at a typical delay of 72 seconds The stage interacts with the DRL auto control to determine the current settings for the delay period and stage timeout and number of trials The DRL auto control includes an Enable Peak Trials option A Peak trial is a trial in which the delay phase lasts longer than the normal delay period a
31. 3 8 What Happens During An Experiment In the majority of cases the operator will not need to take any actions during the course of an experiment protocols are automatic and require no user interaction The protocols will progress until they reach their predefined endpoints It is recommended that the operator refrain from the use of other applications while K Limbic is running a session apart from associated K Limbic applications This is considered good practise when running real time applications Please note during a session K Limbic disables the screen saver 3 9 Ending A Session Prematurely It is possible to end a protocol prematurely should the user wish to do so The details below outline the methods for ending a protocol early If you want to save any data generated so far Click on the Stop All button in the Run Manager or select from the main menu the Session Stop Store Data menu option K Limbic presents an Are you sure you want to do this window Click on Yes This will send all running protocols to their exit stage All data generated to date is saved If you do not want to save any data generated so far Click on the Abort All button in the Run Manager or select from the main menu the Session Abort Discard Data menu option K Limbic presents an Are you sure you want to do this window Click on Yes This will send all running protocols to their exit stage
32. Correct I Trials Incorrect Rewards Disable All Endpoint Counts Cancel Figure 3 15 Edit Endpoint Counts Window Configure the Endpoints Counts Table The counts table is required to set the protocol trials endpoint In the Edit Database Template window click on the Add button select the Endpoints Counts Table entry in the list and click on the OK button Click on the Edit button to display the empty timeout table Add one entry to the table by clicking on the Add button then adjust this entry using the Edit button Enable the Trials All endpoint and set the value to the maximum number of pellets you wish to deliver during one session 1 pellet per trial figure 3 10 illustrates this procedure using a maximum of 100 trials It is feasible to enable more than one count endpoint but for the fixed ratio protocol there is no point in doing so Using a table with a single entry means that this entry will be used by the protocol manager by default if we define a table with more than one entry then during the loading of a session the entries in the table will be presented to the operator who has to select the appropriate value to use as the endpoint for the session This completes the configuration of the database template kK Limbic Developers Guide Tutorial Guide 40 Click on the OK button to close the Edit Endpoint Counts window and then on OK s
33. K LI MBIC DEVELOPER S GUIDE SOF 740 DOC 180 Rev 1 0 Copyright 2007 All Rights Reserved MED Associates Inc P O Box 319 St Albans Vermont 05478 www med associates com K Limbic Developers Guide A Versatile System For The Control Of Behavioural Experiments Conclusive Marketing Ltd The Cottage High Wych Lane Sawbridgeworth CM21 OJR United Kingdom Tel 44 0 1279 724226 Fax 44 0 1279 726177 For product support contact Conclusive Marketing Ltd Information in this booklet is subject to change without notice This document is for use by licensed users of K Limbic or by persons expressly authorised to use K Limbic by Conclusive Marketing Ltd It may be copied and distributed in whole to any existing or potential user of the system Those users shall at their own discretion ignore disregard lose or misinterpret this document or the information contained herein Copyright 2000 2006 Conclusive Marketing Ltd All rights reserved Printed in the UK Document No 2410 01 Printed Sept 2006 kK Limbic User Manual Contents Contents 1 Introduction 1 1 1 2 1 3 Supported Hardware System Requirements Software License Agreement 2 Software Overview K Limbic Terms Starting K Limbic The Main Screen Resources Overview Protocols Overview Subject Databases Overview Sessions Overview Test Suites Overview K Limbic Users Overview 3 Tutorial Guide Create a
34. K Limbic Developers Guide Tutorial Guide 55 Select Session M Fixed Ratio Test Suite Sessions Fixed Ratio Session Cancel Figure 3 27 Select Session Window Database Select Subject Box 1 of 8 Select Subject From List Below Database List Use Selected Subject Leave Box Empty Abort Load Session Figure 3 28 Select Subject Window Select the appropriate subject in the list kK Limbic Developers Guide Tutorial Guide 56 Click on the Use Selected Subject button Next the Select Database Parameter window appears It is prompting you to select the entry in the FR table that is required for the current experiment The protocol will use the FR value in whichever entry is selected in the table Select the required entry in the table and click on OK If an entry with an FR setting of 1 is selected then the protocol becomes a continuous reinforcement type protocol The prompt repeats for the next box and so on until all boxes in the session have been assigned a subject and an entry from the subjects FR table the selection of FR entry may be different in each box Select Database Parameter VI FR Table Subject 1 Box 1 I 30 FR 10 FR 10 Training FR 9 Training FR 8 Training FR Training FR 6 Training FR 5 Training FR 4 Training FR 3 Training FR 2 Trainin Figure 3 29 Select Database Parameter The selected subject is assigned
35. Limbic system even if the system is not configured to run that protocol K Limbic displays the current user name group name and profile in the status bar at the bottom of the main screen It is useful to check that the settings are correct before commencing the development of a protocol test suite From the K Limbic main menu select File User Configure User This will present the Configure User Details window The Current Groups list will contain a single entry Operant Group if this entry does not have an arrow next to it with Current written on the right then select the Operant Group entry in the list and click on the Assign As Current button this will connect the current user to all the files available to the Operant group If the Current Groups list contains more than one group then your system has been configured to use a number of user groups contact your K Limbic system administrator for advice on how they have assigned the groups to determine which group is appropriate It is also possible to modify the password for the current subject using the Modify Password button Click on OK to close the Configure User Details window From the K Limbic main menu select File User Profile Manager This will present the Profile Manager window Profile Manager Profiles Five Choice Add perant lt Current Edit Delete Export Profile
36. Sessions Window The window contains a tab for each of the sessions in the Fixed Ratio Test Suite The test suite includes a single tab for the Fixed Ratio Session The options on the main page were set as part of the Development Test Suite although they can be changed here we do not want to change any of these settings Click on the Configure Data Analysis this presents the Configure Output window Click on the Enable Data Output option so that it is checked Leave the Enable Activity Log option unchecked kK Limbic Developers Guide Tutorial Guide 51 Configure Output V Enable Data Output Configure Session OK Enable Activity Log Cancel Session Output Folder C O0perant FRAD ata M Enable Auto Analysis Figure 3 24 Configure Run Time Sessions Window Click on the Browse For Folder button this presents the Select Folder Session Data window Here we need to navigate to the appropriate folder where we want to store the output data files generated by the Fixed Ratio session A new folder can be created in this window if required It is up to the user to determine where to store the data Network drives are permitted but not recommended A suggested location is illustrated in figure 3 15 Navigate to or create the desired folder location and click on the OK button The selected output data folder appears in the Session Output Folder box Click on th
37. Table Endpoints Counts Table Delete Rearrange Subjects Figure 3 20 Database Maintenance Window Figure 3 20 illustrates the database after it has been populated K Limbic Developers Guide Tutorial Guide 46 Assuming that the instructions on how to Configure The Database Template were followed the Database Template was set up in the Development Test Suite The values in the Development Test Suite were copied into the Database Template in the installed Fixed Ratio Test Suite If you did not configure the Database Template in the Development Test Suite you should configure the Database Template in the Fixed Ratio Test Suite before proceeding click on the Edit Template button and follow the instructions in the Configure The Database Template section above In the Database Maintenance window enter a meaningful value for the database reference this may be an identifier for your squad of animals if there is one otherwise suggest Fixed Ratio Database as the reference for this database Next we need to add in all the subjects in our squad of animals click on the Add Subjects button this presents the Add Subjects window We can either add and name subjects individually using the Add Subject button in the upper section or we can add all our subjects in a single operation using the lower section it is possible to edit individual subjects later if required Adding subject
38. Test Protocol Test Protocol SAM Tooioie m AA Tice ice m Fae unlink Edit Header New Protocol Import Edit Protocol Create Copy Export Lock Protocol Update Protocol Delete Protocol Figure 3 2 Protocol Manager Window The window contains a list of the protocols installed for the current user figure 3 2 illustrates a typical system with a number of protocols already defined Below the list of protocols are a number of buttons used to perform a variety of actions We will use the protocol manager to create the new protocol and access the protocol editor to create and edit the components of the protocol kK Limbic Developers Guide Tutorial Guide 13 The Fixed Ratio Protocol At this stage it would be instructive to discuss the fixed ratio protocol we are about to create A protocol such as this is frequently used to train animals to respond on a lever to receive maximum rewards The flowchart for our protocol is shown in figure 3 4 The protocol performs a simple fixed ratio task In the flowchart each yellow box represents a stage within the protocol As can be seen the protocol has six stages e Start Fixed Ratio Dispense Pellet Correct Trial Pellet Collected Exit The Start stage stage 1 determines the state of the operant chamber prior to running the protocol i e the state of the chamber when the animal is placed into the chamber Once started the protocol enters the fix
39. a Mark Trial stage this time is very short and unperceivable by the subject A Mark Trial Set Outcome stage is essential in any trials based protocol i e a protocol in which the same basic task is repeated many times during a test the stage marks the end of the current trial and instructs the protocol manager to move on to the next trial If all trials in the current protocol have been completed the stage exits via the Trials Complete exit point otherwise the stage exits via the Continue exit point k Limbic Developers Guide Stage Type Reference 93 5 2 6 Fixed Ratio Stage Components Driver Controls Display Message Stage Exit Triggers FR Controls Stage Reports Function A Fixed Ratio stage sets the state of the operant chamber then waits until a specified number of responses the fixed ratio are made on the target dummy sensor or a timeout occurs The Target Dummy setting and the fixed ratio value are specified by the fixed ratio parameters of the subject database A fixed ratio stage may be iterated looped many times during the same trial The stage timeout begins on the first entry to the fixed ratio stage in any one trial it is not reset on subsequent entries to the stage during the same trial This allows the protocol to define an FR phase of a specified length Consider an FR stage with a fixed timeout of 5 minutes each time the subject completes a fixed ratio the prot
40. a constant value for the ratio of 10 5 Incremental 1 100 This is a simple progression where the ratio increases by 1 each time kK Limbic Developers Guide Auto Control Reference 76 4 11 The DMTP Auto Control Delayed Match To Position Delayed Non Match To Position A DMTP auto control is built using a DMTP parameter from the subject database DMTP parameters are available in the database under the following parameter types e DMTP Table e DMTP Parameter A DMTP table is always used in Table mode i e the operator selects one entry from the table for use in the current session The DMTP parameters are intended for use in DMTP tests Refer to the K Limbic repository for a full discussion of the DMTP test Edit DMTP Parameters Comment Training Level 6 Standard Targets Reverse Targets 00 00 02 hh mm ss 2 Lever 2 2 Lever 1 00 00 04 Hi mm 00 00 08 hh mm ss 00 00 16 hh mm ss 00 00 32 hh mm ss Edit Standard Edit Reverse Edit Delays Iterations 8 Total Trials 96 v V Banked Matching Mode C Match To Position Non Match To Position Cancel Trial Control Repeat Incorrect Trials OK Repeat Missed Trials Figure 4 11 DMTP Parameters kK Limbic Developers Guide Auto Control Reference 77 A DMTP control contains the following settings Standard Targets List of available targets levers or sensors Reverse Targets List of available re
41. ables the Dummy setting 4 Leave Enable Rewards as the only checked item in the Control Options section 5 Click on OK to close the window Create another entry in the FR Table by clicking on the Copy button then edit the values in this entry using the Edit button Change this to say an FR5 entry and close the window Repeat this process kK Limbic Developers Guide Tutorial Guide 37 until you have sufficient entries in the FR table to take a subject from novice level up to fully trained for example using FR1 FR2 FR3 FR4 FR5 amp FR10 entries you may prefer to use different values for the FR entries When complete click on the OK button to return to the Edit Database Template window Edit Fixed Ratio Parameters Comment FR10 Ratio Settings Control Options Ratio Enable Reset j Enable Rewards Disable Unused Lever Dummy As Target Target Dummy None G Left Lever Press Right Lever Press Central Lever z f 2 Use Previous f Use Selected Lever Use Selected Sensor Cancel Figure 3 13 Edit Fixed Ratio Parameters Window Configure the Selected Lever Parameters The FR parameter entries opted to define the target lever using the selected lever parameter entry this makes it easier to reassign the target lever to each subject It is good practise to define a database in which half the subjects use the left lever as the target and the half use the right
42. age We do not wish to send a message to the screen display at this time so this step is OK Click on the Next button at the bottom of the window Step 6 of 7 Target Dummy Settings kK Limbic Developers Guide Tutorial Guide 24 We do not require a target dummy setting at this time so the default values of None are OK Click on the Next button at the bottom of the window Step 7 of 7 Stage Reports No output reports are required in this stage so leave the Enable Reports option unchecked so that output reporting is disabled in this stage Click on the Finish button at the bottom of the window The settings for the Dispense Pellet stage are complete so the wizard closes and the new stage is added to the Configured Stages list Add the Correct Trial stage The Correct Trial stage is of the type Mark Trial Set Outcome The Correct Trial stage e Increments the trial number e Marks the trial as Correct The Correct Trial stage marks the end of the current trial The protocol manager performs housekeeping functions whenever a trial marker stage is encountered during a protocol in this case the counts within the fixed ratio stage are reset Trial marker stages are invisible to the subject Select the stage type Mark Trial Set Outcome in the Available Stages list and click on the Build Stage button The Stage Wizard appears the t
43. all subjects will use the same Target lever want half my animals to use the Left lever as the target and half to use the right What should do You have two options here you can e Manually edit half the subjects to set the appropriate Target lever very boring or e Edit the Database Template and copy the new values into half the animals much better To make changes to several subjects at once we use the Copy Tagged Parameters utility The procedure here is to make a change to one or more parameters in the Template tag the modified parameters and then copy the tagged parameters into a list of selected subjects Click on the Copy Tagged Parameters button to present the Copy Tagged Parameters window Copy Tagged Parameters Template Parameters Modify Template Apply Tagged Parameters Not Selected Selected Subjects Apply Dose List Apply Rewards Select Subjects vi Figure 3 21 Copy Tagged Parameters Window Shown with subjects selected Click on the Modify Template button Select the Selected Lever entry in the Parameters list and click on the Edit button This will present the Edit Selected Targets window K Limbic Developers Guide Tutorial Guide 48 Edit Selected Targets Selected Lever Selected Sensor Target Assignments Control Target C None Left Lever Press Right Lever Press Dummy Assignments Control D
44. ange the details already stored in the subjects It is possible to copy changes from the template into one or more subjects as will be discussed later Pre defining the Database Template is not essential but it is recommended The more we pre define at this point the easier it becomes to maintain the database later on especially for experiments where there is a requirement to train animals to perform the task In many cases it is possible to pre define all the steps required to train animals from novice level right through to fully trained For new users of K Limbic this sometimes sounds a little daunting we haven t even started training animals yet and we should pre define what is going to happen in several weeks time Well a remember what has happened in the past training regimes you or someone else have followed kK Limbic Developers Guide Tutorial Guide 34 before you will probably use again pre defining things here simply helps this process and b if your pre defined values are inappropriate it is very easy to change them kK Limbic Developers Guide Tutorial Guide 35 Database Parameters So what database parameters do we need to run the Fixed Ratio protocol All subjects in the database contain a Rewards Table and a Dosing List plus as discussed during the protocol development section the fixed ratio protocol requires up to four more database parameters Rewards Table The rewards table for the FR protocol requires a s
45. appears the title at the top of the wizard should display Step 1 of 5 Lever Positions The Stage entry just below the title displays Shadow Stage delete this entry and enter Pellet Collected instead By default the lever controls are set to No Change this is OK Click on the Next button at the bottom of the window Step 2 of 5 Cue Light States By default the cue light controls are set to No Change this is OK Click on the Next button at the bottom of the window K Limbic Developers Guide Tutorial Guide 25 Step 3 of 5 Enclosure Light States By default the enclosure light controls are set to No Change this is OK for the house light but not for the magazine light Click on the Magazine Light tab and change the setting to Off Click on the Next button at the bottom of the window Step 4 of 5 Display Message We do not wish to send a message to the screen display at this time so this step is OK Click on the Next button at the bottom of the window Step 5 of 5 Stage Reports No output reports are required in this stage so leave the Enable Reports option unchecked so that output reporting is disabled in this stage Click on the Finish button at the bottom of the window The settings for the Pellet Collected stage are complete so the wizard closes and the new stage is added to the Configured Stages list Add the Exit stage T
46. arameters button confirm by clicking on Yes and the modified Selected Lever settings are copied into the selected subjects Click on the OK button to return to the Database Maintenance window The database is now complete Click on the OK button to close the Database Maintenance window kK Limbic Developers Guide Tutorial Guide 50 Configure The Fixed Ratio Session The majority of the session configuration was performed when we created the Development Test Suite All we need to do now is to configure the data output from the session From the K Limbic main menu select Test Suites Configure Sessions This will present the Configure Run Time Sessions window Configure Run Time Sessions Session Details OK Reference Fixed Ratio Session Run List Box 1 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol Copy Session 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol z z 240300 Fixed Ratio Protocol Organise Sessions 240300 Fixed Ratio Protocol Display Type Fixed Ratio Display ion Detail Database Fixed Ratio Database Select Database ___ Session Detals Auto Control Mode NM Enable Dose List Enable Event Log V Enable Shocks Use Subject Parameters Use Template Parameters C Use Duplicate Auto Control Configure Data Analysis Figure 3 23 Configure Run Time
47. atio protocol uses a fixed ratio stage and therefore requires an auto control of type Fixed Ratio Control Click on the icon labelled Auto Parameters the right hand side displays the currently selected Auto Control Type Click on the Edit Auto Parameters button the Configure Auto Parameters window appears Select the Fixed Ratio Control entry in the list The required parameters list will update to indicate that FR Parameters are required in the subject database Click on the OK button to close the Configure Auto Parameters window The Fixed Ratio Auto Control The fixed ratio protocol uses the fixed ratio auto control but what does the fixed ratio auto control provide The fixed ratio auto control produces one or more sets of fixed ratio values the number of sets is determined by the database FR parameters The fixed ratio values are referenced by one or more fixed ratio stages in the protocol In our simple fixed ratio protocol we have one fixed ratio stage therefore an auto control with one set of fixed ratio values is required It is possible for the database parameters to specify more than one set of values however only the first set of values is actually used by the protocol The set of fixed ratio values contains the following settings e Fixed Ratio The number of responses required to complete 1 iteration Target Assignment Controls which sensor is considered the target Dummy A
48. ber Sequential Choice stages are designed to implement protocols where a sequence of cues are presented to the subject followed by the presentation of 2 or more of the cues The sequence and choice parameters are determined by the Sequential Choice database parameters A Cued Choice Stage sets the state of the operant chamber then waits for a response or a timeout Cued Choice stages always reset the stage timer on entry therefore they can be re entered many times in the same trial and will always last for the full timeout period For an example of the use of Cued Choice stages refer to the K Limbic repository kK Limbic Developers Guide Stage Type Reference 109 5 2 21 Cued Lever Stage Components Driver Controls Display Message Task Setting Stage Exit Triggers Stage Reports Function A Cued Lever stage is specifically designed to cater for the Cued Lever Serial Reversal protocol The stage interacts with the Cued Lever auto control to determine the current setting for the target dummy levers and cue lights The stage sets the state of the operant chamber then waits for a response or a timeout Cued Lever stages always reset the stage timer on entry therefore they can be re entered many times in the same trial and will always last for the full timeout period The standard cued lever serial reversal protocols define the flow so that each cued lever stage is used onl
49. ces Conclusive provide the K Limbic repository a collection tried amp tested protocols for this purpose or individual users can also export and share any of their own protocols This tutorial guide explains the process required to develop a simple fixed ratio type protocol from scratch This is intended as an example of the development process the protocol details may not be applicable for your purposes Further guides are available on the settings of a range of protocols The process of creating and editing is common to all protocols These instructions will detail how to Check that the user profile is correctly assigned Create a protocol as an example we will create a Fixed Ratio training protocol Create a Development Test Suite define a session and a database template Build an Installed Test Suite from our Development Test Suite Prepare the Installed Test Suite for use Load and run the session within the Test Suite Os Ol Nyt kK Limbic Developers Guide Tutorial Guide 10 3 1 Check The User Profile The default user contains an operant profile and a five choice profile each profile has it s own resource list this is different from the resource list that was configured during the installation The resources in the user profile are used at certain points in the process of developing protocols and editing databases The use of a separate resource list allows a user to develop a protocol or test suite on their K
50. choice In 50 of trials the assignments are Standard Target Left Sensor lt 1 gt Reverse Target Right Sensor lt 2 gt Standard Dummy Right Sensor lt 2 gt Reverse Dummy Left Sensor lt 1 gt In the other 50 of trials the assignments are Standard Target Right Sensor lt 2 gt Reverse Target Left Sensor lt 1 gt Standard Dummy Left Sensor lt 1 gt Reverse Dummy Right Sensor lt 2 gt SS SS i The assignments of the T maze Random auto control are useable in any stage where it is possible to set the Target or Dummy to the Standard Auto or Reverse Auto settings and where an Auto Timeout exit trigger is used kK Limbic Developers Guide Auto Control Reference 74 4 10 The Progressive Ratio Auto Control A Progressive Ratio auto control is built using a progressive ratio parameter from the subject database Progressive ratio parameters are available in the database under the following parameter types e Progressive Ratio Table e Progressive Ratio Parameters A Progressive Ratio table is always used in Table mode i e the operator selects one entry from the table for use in the current session The progressive ratio parameters are intended for use in progressive ratio tests the values held ina progressive ratio control are used by progressive ratio stages in the protocol Edit PR Parameters Comment Example Progressive Ratio Progression Control Options Enable Reset Fin 5 x EXP
51. components for each stage type are listed under each stage type in this reference In most cases the components for each stage type are tailored to suit the specific behaviour of that stage type for example the available stage reports for a fixed ratio stage are different from the stage reports for a reward stage etc The common components of a stage e Driver Controls The driver controls specify the settings for each resource in the protocol i e retractable levers cue lights enclosure lights tones feeders fans etc The stage wizard only presents controls for the particular resources defined in the protocol e Display Message A stage can send a message to the on screen display during a session a display message may inform the display for instance that the protocol has moved from a VI phase to an FR phase or that counting on a resource has been disabled e Target Dummy Settings Targets amp Dummies are important in many protocols in general a target identifies the correct response sensor and the dummy identifies one or more incorrect response sensors e Stage Exit Triggers specify how the stage will end i e on a timeout a response on the target sensor or a completed fixed ratio etc e Stage Reports Allows the developer to tailor the contents of the output file The components above are common to most stage types although not all stage types have all the above components In addition stage
52. creates one output file for each session it runs the session output file contains the raw data for each subject run during the session The session file is stored in the data folder specified in the session configuration The filename is automatic and of the form 01 Jan 2006_nnn csv the nnn value is a number between 001 amp 999 allowing K Limbic to store a total of 999 sessions of data per day Generated Files Combined Files In addition to the session files K Limbic also maintains a combined file The combined file contains all the session files for any given day The combined file reduces the data handling considerably as only one data file per day is required for raw data storage or analysis The combined file is stored in the data folder specified in the session configuration The filename is automatic and of the form 01 Jan 2006_Combined csv An Excel file is included with the developers guide filename Output File xls please refer to the example file for examples of each portion of the output file File Content The contents of an output file consists of a number of sections these sections are Header Data Auto Control Data Trials Data Activity Log Data kK Limbic Developers Guide Output File Format 116 Header Data The header data consists of a number of items that are output from all protocols All output files contain a header section The STARTDATA cell marks the beginning of the data for one
53. d Dummy Right Sensor lt 2 gt Reverse Dummy Left Sensor lt 1 gt we YDS a The assignments of the T maze Constant auto control are useable in any stage where it is possible to set the Target or Dummy to the Standard Auto or Reverse Auto settings and where an Auto Timeout exit trigger is used K Limbic Developers Guide Auto Control Reference 73 4 9 The T Maze Random Auto Control A T Maze Random auto control is built using an Iterations parameter and Delay Table from the subject database The T Maze Random auto control generates a list of trials Each trial in the list assigns a Standard target Reverse target Standard dummy Reverse dummy and an auto timeout The number of trials generated is determined by the value of the Iterations parameter one trial per iteration The operator selects one entry from the delay table for each subject the delay value is used as the auto timeout value for all trials The T Maze Random auto control is intended for use in T Maze tests where the choice of direction determines the difference between a correct and incorrect trial in 50 of trials the correct choice of direction is right and in 50 of trials the correct choice is left The protocol must define resources of type Sensor lt 1 gt amp Sensor lt 2 gt we have assumed here the Sensor lt 1 gt detects a Left choice and Sensor lt 2 gt detects a Right
54. d value of delay is used in any stages of type Delay Stage in the protocol the delay value is used as the Auto Delay during the stage Edit Parameter Table Delay Table Entries 00 00 20 hh mm ss 00 00 10 hh mm ss Add 00 00 05 hh mm ss 00 00 00 hh mm ss Edit Copy Delete Set 4s Default m Table Style Selection Controls Use In Table Mode Select at Run Time C Use ln Series Mode C Use Default OK Cancel Figure 4 4 Delay Table kK Limbic Developers Guide Auto Control Reference 67 4 5 The Random Lever Auto Control A Random Lever auto control is built using an Iterations parameter from the subject database The random lever auto control generates a list of trials each trial assigns the levers as either a Standard target Reverse target Standard dummy or Reverse dummy The number of trials generated is determined by the value of the Iterations parameter and the number of levers in the Resource list of the protocol For example if a protocol defines two levers in its resource list and the database parameter specifies that 50 iterations are required then a total of 100 trials will be generated In 50 of the trials the lever assignments will be as follows Standard Target Left Lever Reverse Target Right Lever Standard Dummy Right Lever Reverse Dummy Left Lever In the other 50 trials the lever assignments will be as follow
55. developer defines the experiment as a set of distinct stages this is most easily represented as a graphical flowchart Movement between stages is triggered by a trigger event examples of trigger events are timeouts lever presses and nose pokes The protocol description is defined using a number of components These are as follows The Header component the Reference Title amp Description of the protocol The Resources component the items required in the operant chamber The Stages component a list of stages for the experiment The Endpoints component a list of endpoint conditions The Process component the flow between stages The Auto Parameters component how to customise the protocol for individual subjects A range of stage types is available to cater for various experimental situations the range of stage types is listed in table 2 2 The stage types have been created to permit the developer to create a wide range of experiments Experiment specific behaviour is included in some stage types such as in the case of Serial Choice type stages Experiment specific stage types make defining protocols easier as some expert knowledge is included in the stage itself removing the need for the developer to create the behaviour from scratch Table 2 2 Predefined K Limbic Stage Types Stage Type Function Initial Stage Sets the initial state of the operant box state prior to starting the protocol E
56. distraction tone burst Has no effect when using Med Associates hardware The five choice auto control assumes that five stimulus lights will be active in the protocol Edit Serial Choice Parameters Comment MV Automatic Comment Control Parameters Iterations Inter Trial Interval Active Channel 20 505 Banked Stimulus Parameters Control Parameters Cancel Figure 4 7 Five Choice Control Parameters kK Limbic Developers Guide Auto Control Reference 71 The number of trials generated depends on the Iterations setting and the mode of the table In Table mode the operator selects one entry from the table all trials in the session are built using the values held in this one entry The number of trials is calculated as Trials 5 Stimulus lights x Iterations e g To generate a session with 100 trials set the Iterations parameter to 20 In Series mode the trials in the session are built using all values in the table The number of trials is calculated as Trials 5 Stimulus Lights x Iterations x Entries e g With a table with 4 entries to generate a session with 100 trials set the Iterations parameter to 5 The five choice table auto control is used by the Serial Choice stages held in a protocol For a full discussion of the use of the five choice auto control please refer to the protocol description documents of any of the five choice serial reaction time task protocols held in the K Limbic
57. during the experiment The Air Puff Count is the total of all air puffs delivered during the experiment The Shock Count is the total number of shocks delivered during the experiment The F 10 Sensor identifies the sensor that was first activated 10 times The SL Target identifies the index of the target lever from the selected lever parameters The SL Dummy identifies the index of the dummy lever from the selected lever parameters The SS Target identifies the index of the target sensor from the selected sensor parameters The SS Dummy identifies the index of the dummy sensor from the selected sensor parameters The SensorTC lists the activation counts of each of the sensors e g S 1 S 2 etc It can be seen that in most cases the majority of the header items are not required for data analysis and can be ignored To extract any particular value from the header search for the identifier in column A and read the value k Limbic Developers Guide Output File Format 117 Auto Control Data The auto control data lists details of the auto control generated for use with the experiment All output files contain an auto control section even those that do not use an auto control The auto control data starts with the AutoControl identifier in column A The contents of the auto control vary depending on which form of auto control is specified in the protocol The fields
58. e Configure Stages window is used to add delete and edit the stages of the protocol Configure Stages Configured Stages Available Stages Initial Stage q gt Fixed Ratio Exit Stage Dispense Pellet Action Stage gt Pellet Collected Reward Stage Increment Trial Mark Trial Set Outcome Exit Stage Fixed Ratio VI Stage FR Meted Shadow Stage Timer Stage Serial Choice Inter Trial Interval Serial Choice Present Stimulus Serial Choice Collection Serial Choice Timeout Serial Choice Training Interval Stage Delay Stage Progressive Ratio Stage nee Cusd Choice Staga v Add Delete Stages Build Stage OK Cancel Figure 3 7 The Configure Stages Window We have a couple of options as to how to add all the stages to our protocol we can either add all the stages together and then edit them or we can use the Build Stage button to add and edit stages individually in either case the editing process is exactly the same so it is simply a matter of personal preference Here we will use the Build Stage button Add the Start stage The Start stage is of the type Initial Stage All protocols must have one stage of type Initial Stage By conventional the Initial Stage is always called Start and is listed as stage 1 In this guide the terms Initial Stage and Start are considered synonymous The Start stage determines the state of the operant chamber prior to the start of the pr
59. e OK button to return to the Configure Run Time Sessions window Click on the OK button to return to the K Limbic main screen From the K Limbic main menu select File Close Test Suite The settings in the Fixed Ratio Test Suite are saved Congratulations You have completed the full development and configuration of a K Limbic experiment and not just a simple Hello World style example experiment the Fixed Ratio Test Suite is fully operational and usable for live experiments Automated Data Analysis Once again the keen eyed observer will have noticed an omission What about the automated connection to the data analysis The configuration of the automated data analysis has been omitted from this section for brevity Conclusive recommend the use of automated data analysis packages as they significantly reduce the daily effort required to analyse your data they are a leap ahead in the field of data analysis for operant experiments If you have purchased an analysis package for the Fixed Ratio task you must configure the session to connect to the analysis package Instructions on how to do this are given in the analysis package user guide kK Limbic Developers Guide Tutorial Guide 52 Important Note It is now necessary to exit and restart K Limbic prior to running a first session with K Limbic In some cases running a session from a test suite that has just been created causes a problem The op
60. e Software Overview 7 The important thing to note is that protocol definitions are generic the protocol manager interacts with the details held in the database parameters of an individual subject to customise the protocol to a given subject For example in the well known delayed match to position task the database parameters determine the number of trials to be performed the delay values to be used the maximum time allowed for the experiment whether or not the task is matched to position or non matched to position whether or not incorrect trials are repeated and whether or not trials are organised in banks As the details are subject specific you can run a session in which the details of the protocol running in box1 are completely different from the protocol running in box 2 etc This is achieved simply by assigning a subject to a chamber The list in table 2 2 details the various stages available to build a protocol If you have a protocol that is not catered for by the current stage types Conclusive want to hear from you we like nothing more than adding new stuff into K Limbic Contact us with your requirements and we will add in the necessary controls to create your protocol we can do this quickly and efficiently normally the longest process is communicating the details of the task once your new facilities are added you will be able to adapt and run new protocols The need to have new stage types added i
61. e Tutorial Guide 30 The Required Parameters list specifies that all subjects in the subject database contain the three entries listed above In addition if the FR Parameters specify that the target assignment is set to Use Selected Lever as will be the case in our database a Selected Lever parameter will also be required Close The Protocol Editor The fixed ratio protocol is now complete and we can close the protocol editor Select File Exit from the menu in the protocol editor window and click on Yes to save the changes to the protocol Click on the Exit button to close the Protocol Manager The protocol file is now complete kK Limbic Developers Guide Tutorial Guide 31 3 3 Create A Development Test Suite To use the fixed ratio protocol to run a session we need to create a Development Test Suite and then an installed test suite Test Suites are created edited and managed using the Test Suite Manager From the K Limbic main menu select Test Suites Test Suite Manager or press function key F4 This will present the Test Suite Manager window Test Suite Manager Development Test Suites Installed Test Suites DMTP 01 DMTP Test Suite DMTP Training amp Study DMTP 02 DMTP Training Training Protocols CER 01 CER Test Suite Conditioned Emotional Response Go Nogo 01 Go Nogo Test Suite Go Nogo Test Suite FR 01 Fixed Ratio Suite Fixed Ratio Protocols 375001 Voge
62. e stages list is the selected Source stage in the fixed ratio protocol this is the Start stage The Start stage has a single destination labelled as Continue the protocol moves from the Start stage to the Continue destination when the operator issues the start of session command The Fixed Ratio stage is the destination of the Start stage ensure the Fixed Ratio stage is selected in the Destinations list and click on the Assign Destination button The Continue destination is updated This completes the process for the Start stage In the Source Stage list select the Fixed Ratio stage the destinations list updates to display three entries Set the destinations as below e Ratio Complete On Target Dispense Pellet e On Shadow Trigger Pellet Collected e Protocol Timeout Exit This completes the process for the Fixed Ratio stage In the Source Stage list select the Dispense Pellet stage the destinations list updates to display two entries Set the destinations as below e Continue Correct Trial e Rewards Endpoint Exit This completes the process for the Dispense Pellet stage The Rewards Endpoint entry is displayed because of the Counts endpoint The Counts endpoint may specify a maximum number of rewards If the maximum number of rewards is triggered then the protocol will pass to the Exit stage thus ending the pr
63. e trials table used by the current trial it increments at the end of each trial however if a trial is repeated the Item Index does not increment The following are the numerical codes for each trial outcome Correct Trial Incorrect Trial Missed Trial Repeat Trial Incomplete Trial Rewards Endpoint Idle Timeout No Reward Timeout Protocol Timeout 128 Trials Complete 150 User Termination 1 NOOR WNM O All timings are reported in centiseconds and are relative to the start of the protocol The Trials Data sheet of the example file illustrates the Trials Data section for a 100 trial five choice test The Individual Subject sheet of the example file illustrates the Trials Data section for a fixed ratio task that uses a single trial the trials data therefore becomes a summary over the entire session kK Limbic Developers Guide Output File Format 119 Activity Log Data The Activity Log section is a list of the activity reports created during the test Not all output files contain an Activity Log Data section Enable the activity log section by enabling the Activity Log in the session configuration Refer to the Activity Log Data page of the Output File xls file for an example activity log All rows in the activity log start with one of the following identifiers ACTIVITYLOG TRIAL DATA END The activity log section commences with the ACTIVITYLOG identifier The act
64. e types such as in the case of Serial Choice type stages Experiment specific stage types make defining protocols easier as some expert knowledge is included in the stage itself removing the need for the developer to create the behaviour from scratch The Serial Choice Present Stimulus stage provides an example of experiment specific behaviour The stage has the built in behaviour of presenting a stimulus in one of the niche lights and then waiting for the limited hold period for a response The stage automatically retrieves the stimulus parameters and the limited hold period from the auto control the developer simply defines the protocol with the stage in the correct place and the stimulus will appear Table 5 1 K Limbic Stage Types Stage Type Initial Stage Exit Stage Action Reward Mark Trial Set Outcome Fixed Ratio Fixed Ratio Meted Variable Interval Shadow Stage Timer Stage Serial Choice Inter Trial Interval Serial Choice Present Stimulus Serial Choice Collection Serial Choice Timeout Serial Choice Training Interval Stage Delay Stage Progressive Ratio Stage Cued Choice Stage Sequential Choice Stage Cued Lever Stage Epoch Control Stage Outcome Stage DRL Stage Timeout Stage Location Stage Function Sets the initial state of the operant box prior to starting the protocol Sets the exit state of the protocol following completion of protocol Waits for a trig
65. ects displaying a bias towards one lever i e animals that always press the same lever at the choice stage which would result in 50 of trials being correct K Limbic Developers Guide Auto Control Reference 78 The settings in the DMTP auto control are accessed in any stage where it is possible to set the Target Dummy options to Standard Auto or Reverse Auto Access the delay value from any stage with the Use Auto Timeout exit trigger The standard DMTP protocol uses Action stages refer to protocol 240150 in the K Limbic repository Target Dummy Assignments with the DMTP control An important aspect of using the DMTP control is the understanding of how the Standard amp Reverse targets are assigned to the Target amp Dummy resources during the protocol Using the Standard Auto option If the Target assignment in any stage is set to Standard Auto then the Standard Target from the DMTP control for the current trial will be assigned as the Target resource If the Dummy assignment in any stage is set to Standard Auto then Reverse Target from the DMTP control for the current trial will be assigned as the Dummy resource Using the Reverse Auto option The result of using the Reverse Auto option is determined by the Matching Mode value In Match To Position mode If the Target assignment in any stage is set to
66. ed by exit trigger number 2 Reward Dispensed Report generated whenever a reward is dispensed 2006 DS 2 F 0 2345 The value 2 is the index of the current stage The index is zero based thus stage 1 is reported as 0 stage 2 is reported as 1 etc F 0 identifies that fluid dispenser lt 1 gt dispensed the reward 23 45 seconds after the start of the session
67. ed in when a sensor is released The Message Filter setting has no effect in the Med Associates version of K Limbic k Limbic Developers Guide Stage Type Reference 89 5 2 2 Exit Stage Components e Driver Controls Function An Exit Stage sets the state of the operant chamber subsequent to the end of the session The Exit Stage is active when the protocol is complete If the flow of an experiment sends the protocol to the exit stage then the protocol is considered to have ended even if none of the specified endpoints have been triggered All protocols require one stage of type Exit Stage by convention the Exit Stage appears as the final stage in the stage list and is called Exit The Initial Stage does not monitor the state of the sensors therefore it produces no output k Limbic Developers Guide Stage Type Reference 90 5 2 3 Action Stage Components Driver Controls Display Message Target Dummy Settings Stage Exit Triggers Stage Reports Function An Action Stage sets the state of the operant chamber then waits for a response or a timeout The Target Dummy setting for an action stage may be a specified sensor or the Standard or Reverse sensor as defined for the current trial in the auto control The timeout value may be a pre defined fixed timeout or the Delay value for the current trial in the auto control Action stages always r
68. ed ratio stage stage 2 this stage extends a single lever into the chamber and pauses until the current FR schedule is completed on the lever when the FR is complete the stage ends and the protocol triggers a pellet delivery stage 3 this stage simply triggers the pellet dispenser it does not wait for the pellet to be delivered in addition this stage also turns on the magazine light as a signal to the animal that the pellet is present in the receptacle The protocol then marks this trial as correct and increments the trial number the protocol then loops back to the fixed ratio stage and starts again Stage 5 Pellet Collected is triggered when the subject collects the pellet from the receptacle sensed using a head entry detector stage 5 turns the magazine light off and then returns to the fixed ratio stage The loop continues until the end of the protocol this is triggered by a protocol timeout or a count endpoint The user specifies the protocol timeout for sake of this guide we will assume a value of 20 minutes Targets amp Dummies The assignment of target amp dummy resources is important in most protocols In general a target identifies the correct response sensor and the dummy identifies one or more incorrect response sensors A number of stage types provide controls for setting the Target and Dummy whereas several stage types set the Target amp Dummy sensors automatically For
69. een stages The Auto Parameters component how to customise the protocol for individual subjects We have already set the entries in the header but as can be seen the Title amp Description can be modified here Modify the Reference entry by using the Edit Header button from the Protocol Manager window kK Limbic Developers Guide Tutorial Guide 18 The Resources Component Click on the icon labelled Resources the right hand side displays the current list of Resources Perhaps surprisingly the list is populated already this is because the list of resources defined for the current profile has automatically been copied into the protocol as it was created The initial list of resources in the protocol will therefore depend on the resources list of the current profile however if the default settings have been left in place the resource list should look like that shown in figure 3 6 Configured Resources Right Lever Left Cue Light Edit Resources Right Cue Light House Light Magazine Light Pellet Dispenser Left Lever Press Right Lever Press Magazine Sensor Figure 3 6 The Configured Resources The resource list contains e Two retractable lever controls Left Lever amp Right Lever Two cue lights Left Cue Light amp Right Cue Light Two lights House Light amp Magazine Light One pellet dispenser Two lever press sensors Left Lever Press amp Right Lever Press One sensor Magazine Sensor a head ent
70. erant chamber normally just the house light then illuminates any niche that has been defined as a target in the Target Position options The stage then waits for a response in any sensor or for the optional stage timeout to occur The general intention of the Serial Choice Training stage is to create simple continuous reinforcement CRF protocols where all stimulus lights are illuminated and a response in any niche results in a pellet delivery K Limbic Developers Guide Stage Type Reference 103 5 2 16 Interval Stage Components Driver Controls Display Message Target Dummy Settings Stage Exit Triggers Interval Controls Stage Reports Function An Interval stage provides a period sub divided into smaller intervals An Interval stage is similar to a Variable Interval stage however it includes additional control options Variable intervals are used commonly in operant tasks where it is desirable to encourage a subject to respond at a high rate An Interval stage lasts for a period specified in the Stage Exit Trigger options The stage timeout is either a fixed timeout or an auto timeout auto timeouts are specified using the Auto Timeout parameters of the subject database The intervals of an Interval stage may be either variable intervals extracted from a Variable Interval auto control or fixed intervals specified in the Interval Controls options
71. erator is able to load a session and run it without any problems however K Limbic freezes when the operator selects the command to close down the session This error occurs on some machines and not others and only affects closing down the session the first time a session is run in a newly built test suite It does not happen at any other time The simple method of never encountering this problem is to exit K Limbic and restart the application Conclusive Marketing Ltd apologise for this bug we will remove the problem as soon as possible kK Limbic Developers Guide Tutorial Guide 53 3 6 Check The Chamber Definition Prior to loading the session for the first time it is a good idea to check the chamber resources The protocol defines a list of resources that it expects to control in the chamber see section 3 2 part of the process of loading a session includes checking that all resources in the protocol have corresponding entries in the Chamber Definition The Chamber Definition informs the system of which channel each resource uses in the chamber To check that the chamber definition is correct From the K Limbic main menu select Configure Define Chamber This will present the Display Chamber Resources window as shown below Display Chamber Resources Chamber Resources Description Operant Resource List Cancel Right Lever Lever Control lt 2 gt OK Left Cue Light Cue Light lt
72. eset the stage timer on entry therefore they can be re entered many times in the same trial and will always last for the full timeout period k Limbic Developers Guide Stage Type Reference 91 5 2 4 Reward Stage Components Rewards amp Shocks Driver Controls Display Message Target Dummy Settings Stage Reports Function A Reward Stage triggers the delivery of a reinforcer A reinforcer may be reward device such as a pellet dispenser or syringe pump or it may be a shock generator A Reward Stage also sets the state of the operant chamber The trigger generated by a reward stage is a pulse of a user specified pulse length The pulse length is specified using the Rewards Table of the subject database A Reward Stage is instantaneous although there is a finite time taken to process a reward stage this time is very short and unperceivable by the subject the protocol triggers the reinforcer sets the state of the operant chamber and then moves directly to the next stage The end of the reward stage is immediate it does not wait until the end of the trigger pulse A reward stage does not monitor the pellet dispenser status line or the pellet delivery sensor Rewards amp Shocks A reward reinforcer may be disabled unconditionally enabled or conditionally enabled Dispense If Target A dispenser is a target if it has the same index as the current target resource for instance if
73. eters to a specific experimental protocol has required a custom written program for each particular experiment performed K Limbic provides a simple intuitive method of controlling behavioural experiments thus enabling the user to create individual experiments and please remember all this is done without the requirement for a programmer The essential themes of the K Limbic design are ease of use versatility and reliability The K Limbic system is in daily use in many global pharmaceutical companies testament to the quality of its development The flexible design means that K Limbic is just as suited to a small independent laboratory or university department as it is to major corporations The K Limbic design focuses on the major tasks that are presented to any successful behavioural or cognition laboratory Experimental task development is made simple by the use of the powerful protocol definition methodology animal training and maintenance is easy with the use of the subject database and most importantly K Limbic is the first the only operant control system to automatically connect with data analysis macros to archive meaningful datasets on a per animal or per group basis This document describes how to develop and edit a K Limbic protocol Protocols determine the generic behaviour of an experiment and specify how the protocol will connect with the subject database to produce a specific behaviour tailored to the subject performing the test A t
74. everal more times to return to the Configure Test Suite window K Limbic Developers Guide Tutorial Guide 41 Configure The Sessions The Fixed Ratio Test Suite requires a session to run the fixed ratio protocol In the Sessions section of the Configure Test Suite window click on the Add button this will add an empty session to the Test Suite the session is titled Session 1 Fixed Ratio Session We will set up all boxes in the session to run the fixed ratio protocol Select Session 1 in the Sessions list and click on the Edit button this presents the Configure Session window We will configure this Session as the fixed ratio session Configure Session Session Details Reference Fixed Ratio Session Cancel Run List 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol x 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol Configure Run List Display Type ae Fixed Ratio Displa Aute Control Mode V Enable Dose List Enable Event Log V Enable Shocks Use Subject Parameters C Use Template Parameters C Use Duplicate Auto Control Figure 3 16 Confiqure Session Window Modify the Reference entry to a meaningful value e g Fixed Ratio Session Click on the Configure Run List button to present t
75. example an Action stage type provides controls for setting the either the Target or the Dummy to the following options e None Selected Lever Selected Sensor All Levers All Sensors Standard Auto Reverse Auto Assigned Resource Use Previous The effect of selecting an option from the above list is as follows None No target dummy assigned Selected Lever Extract the setting from the Selected Lever database parameters Selected Sensor Extract the setting from the Selected Sensor database Parameters All Levers Set all levers as targets dummies All Sensors Set all sensors as target dummies Standard Auto Extract the setting from the auto control Reverse Auto Extract the setting from the auto control Assigned Resource Assign a specific resource as the target dummy Use Previous Retain the setting from the previous stage s Target and dummy resources are assigned at each stage therefore in say a protocol that uses two retractable levers either lever can be assigned as the target lever at any stage in the protocol kK Limbic Developers Guide Tutorial Guide 14 In many cases the auto control of the protocol will determine which lever is the current target for instance in a DMTP protocol the sample lever is the target The auto control contains a setting for the target for each trial in the protocol Using the auto control to assign the target is achieved by selecting the Standard Auto or Reverse Auto
76. f trials just as the subject is expecting to see the stimulus the tone sounds to distract the subject the actual stimulus appears 5 seconds later Alternatively the distraction tone could be set to present at the end of the ITI i e coincident with the stimulus The Serial Choice Inter Trial Interval stage always resets the stage timer on entry therefore it can be re entered many times in the same trial and will always last for the full ITI period The Serial Choice Inter Trial Interval stage automatically assigns all nosepoke sensors in the chamber as Dummy resources i e all the niche sensors A response in any niche during the ITI is normally considered a premature response i e a response prior to the stimulus A five choice paradigm normally sends the protocol into a timeout state as a result of a premature response The Target resource may be any sensor in the chamber that is not a nosepoke sensor kK Limbic Developers Guide Stage Type Reference 99 5 2 12 Serial Choice Present Stimulus Stage Components e Driver Controls e Display Message e Stage Exit Triggers e Stage Reports Function A Serial Choice Present Stimulus stage is specifically designed to perform the Present Stimulus function in the five choice serial reaction time task The stage sets the state of the operant chamber normally just the house light then presents the stimulus the stimulus is
77. ger to occur Dispenses a reward reinforcement Increments the trial number amp defines the outcome of a trial e g correct incorrect etc Runs a fixed ratio Runs a fixed ratio Runs a variable interval Responds to the activation of a shadow trigger Used To Time the period of activation of a sensor The ITI stage of the 5CSRTT The stimulus amp limited hold of the 5CSRTT The Wait for collection stage of the 5CSRTT The Timeout stage of the 5CSRTT A training stage for the 5CSRTT A fixed or variable interval stage Waits for a specified delay to occur Implements a progressive ratio schedule Used in DNMTP protocols Defines a series of responses Defines a cued lever stage Controls the epoch manager Set the outcome of a trial Used in DRL tests A general timeout stage Defines the location of a subject k Limbic Developers Guide Stage Type Reference 87 5 1 The Components Of A Stage All stages are built from a number of components To develop a protocol the developer needs to edit the settings in each component of each stage The Stage Wizard is provided to assist the developer in this process see the tutorial guide The stage wizard steps through each component of a stage and provides controls for the developer to select the required setting for each component In general each stage has the components listed below some stages have additional components to provide a specific behaviour the
78. hanges state Exit On Any Sensor This is useful if you wish to start the timing from when you place the subject into the environment In this case you start the session before placing the subject into the environment the protocol enters a Location stage with the Exit On Any Sensor endpoint enabled Wait for Subject When you place the subject into the environment it is normal for one or more position sensors to become active this will trigger the end of the Wait For Subject stage and the protocol can begin it s timing A protocol that uses any Location stages should not enable the Message Filter see the Initial stage description kK Limbic Developers Guide Output File Format 115 Section 6 Output File Format The output file generated by K Limbic is a comma separated variables CSV file suitable for import to common spreadsheet packages such as MS Excel or databases such as MS Access This section details the components within the output file for those users who wish to analyse their data files using their own data analysis utilities The automated analysis facility offered by Conclusive Solutions uses MS Visual Basic hosted within MS Excel Those opting to use one of the automated analysis packages obtain output as an Excel workbook containing customised results and performance histories the CSV files are used only for raw data storage Generated Files Session Files K Limbic
79. he Configure Run List window this is where we tell K Limbic how many boxes to run and which protocol to run in which box Click the Add Box button once this adds an empty box to the run list Select the Fixed Ratio protocol reference 240300 in the Protocols list and click on the Assign Protocol To Box button this configures Box 1 to run the Fixed Ratio protocol Click on the Add Box button again this will add another box to the Run List by default this box will run the same protocol as Box 1 which is what we want Click again on Add Box until the Run List contains the correct number of boxes all running the Fixed Ratio protocol you need one entry in the Run List for each box in your system kK Limbic Developers Guide Tutorial Guide 42 Configure Run List Run List Protocols 240300 Fixed Ratio Protocol 240150 DMTP Protocol 240300 Fixed Ratio Protocol 240151 Pellet Training 240300 Fixed Ratio Protocol Add Box 240152 CRF Training 240300 Fixed Ratio Protocol 240153 Cued CRF Task 240300 Fixed Ratio Protocol 240200 CER Protocol 240300 Fixed Ratio Protocol Delete Box 240250 Go Nogo Protocol 240300 Fixed Ratio Protocol 240300 Fixed Ratio Protocol 2402003 CER Protocol 375001 Vogel Test A 375002 Vogel Test B 500 Diplomat Test 203420 CSR 203420 203421 CSR 203421 240200TT CER Protocol Test i Assign Protocol To Box OK Cancel Figure 3 17 Configure Run List
80. he Exit stage is of the type Exit Stage All protocols must have one stage of type Exit Stage By conventional the Exit Stage is always called Exit and is listed as the final stage in the stage list In this guide the terms Exit Stage and Exit are considered synonymous The Exit stage determines the state of the operant chamber after the end of the protocol In our case we want the levers to be retracted and all lights off these are the default values of the Exit stage Select the stage type Exit Stage in the Available Stages list and click on the Build Stage button The Stage Wizard appears the title at the top of the wizard should display Step 1 of 3 Lever Positions The Stage entry just below the title displays Exit Stage delete this entry and enter Exit instead By default the levers are retracted so step 1 is OK Click on the Next button at the bottom of the window Step 2 of 3 Cue Light States By default the cue lights are off so step 2 is OK Click on the Next button at the bottom of the window Step 3 of 3 Enclosure Light States By default the enclosure lights are off so step 3 is OK Click on the Finish button at the bottom of the window The settings for the Exit Stage stage are complete so the wizard closes and the new stage is added to the Configured Stages list The Configured Stages list now contains the six s
81. ick on OK to close the Edit Reward Table window and OK to close the Edit Rewards table Configure the Dosing List click on the Edit Dosing List button The default dosing list is empty we want to add a single No Dose entry to the list Click on the Add button to add an entry to the dosing list Click on the Edit button to display the Edit Dose window Change the entries to those shown below K Limbic Developers Guide Tutorial Guide 36 Edit Dose Table Entry 1 Dose Details Dose Detail No Dose Pre Dose Period 999 Dose Category paa Dose Type Active Drug C Inactive Control Figure 3 12 Configure Test Suite Header Window The precise meaning of each entry is unimportant here the settings are discussed in the description documents for the automated analyses Click on the OK button to close the window A dosing list with a single entry will automatically assign the entry as the default entry During the process to load a session the protocol manager will interrogate the database to determine which dose has been given to a subject if the list contains a default entry then the default dose will automatically be assigned to the subject Obviously during training you will not administer a drug to the subjects so having a default No Dose entry in the dosing list is useful Click on the OK button to return to the Edit Database Te
82. ide Stage Type Reference 98 5 2 11 Serial Choice Inter Trial Interval Stage Components Driver Controls Display Message Target Dummy Settings Stage Exit Triggers Stage Reports Function A Serial Choice Inter Trial Interval stage is specifically designed to perform the inter trial interval ITI function in the five choice serial reaction time task The stage sets the state of the operant chamber normally just the house light then pauses for a specified period the ITI The ITI is specified as a fixed stage timeout or uses the ITI setting of the five choice parameters of the subject database Using the database is the preferred method as it allows for multiple ITI values during the same session Time variable tone presentation is a special function of the serial choice inter trial interval stage The five choice parameters include optional settings for the distraction tone In any trial it is possible to trigger the tone at either the beginning the end or half way through the ITI period The developer decides when they want the tone to appear and sets the appropriate value in the subject database For example a session may include two types of trial in one type the ITI is 5 seconds duration in the other type of trial the ITI is 10 seconds duration but at T 2 5 seconds the ITI stage presents distraction tone The stimulus presentation immediately follows the ITI stage In other words in 50 o
83. iew A Resource is a single item of operant equipment a list of the resources which are currently supported by K Limbic is given in table 2 1 K Limbic defines an operant enclosure as of a collection of resources i e a group of associated levers lights doors etc K Limbic controls the state of an operant enclosure by controlling the state of each resource in the resources list of the protocol Table 2 1 Available K Limbic Resources Retractable Levers Cue Lights Lights Door Control Tone Generator Pellet Dispenser Fluid Dispenser Auxiliary Dispenser Shock Trigger Fan Feeder Control Retractable water bottle Lever Press Sensor Sensor Nose Poke Sensor Position Sensor The resources present in an operant enclosure will vary depending on the nature of the experiment it is used for A K Limbic developer configures a collection of resources as a part of the protocol description The state of each configured resource is controlled at every stage of the protocol thus controlling the state of the operant enclosure kK Limbic Developers Guide Software Overview 6 2 5 Protocols Overview K Limbic is a tool for performing user defined experiments The method provided for the user to define the actions of an experiment is the protocol A K Limbic protocol is a series of stages at each stage the current state of an operant enclosure is fully defined i e the state of any resources present in the enclosure is specified The
84. in more detail later kK Limbic Developers Guide Software Overview 2 2 Starting K Limbic The K Limbic installation program creates a K Limbic item on the Start menu All Programs gt gt K Limbic gt gt K Limbic System Select this item to start the K Limbic application K Limbic will present the log in window select the appropriate user name from the list and enter the appropriate password kK Limbic Developers Guide Software Overview 4 2 3 The Main Screen Enter K Limbic by selecting the K Limbic item from the Windows Start Menu and log in The software is loaded and presents the main screen to the user The main screen components are listed below 1 The main menu The main menu appears below the title bar the main menu gives the user access to the various functions of K Limbic 2 The toolbar The toolbar gives shortcut access to the main management windows of K Limbic 3 The user details section The user details section gives an outline of the protocols and test suites that the current user has defined 4 The Test Suite section The Test Suite section lists the primary database for the current test suite if one is loaded this area also lists the recent activities performed with the test suite 5 The System Log The system log is a list of recent activity that has occurred using K Limbic The system log holds data for up to ten days kK Limbic Developers Guide Software Overview 5 2 4 Resources Overv
85. independent of the dose type of the assigned dose Click on the OK button to close the Edit Selected Targets window Edit Selected Targets Selected Lever Selected Sensor Target Assignments Control Target C None Left Lever Press C Right Lever Press Dummy Assignments Control Dummy None C Left Lever Press C Right Lever Press Active Target Active Dummy None C Left Lever Press C Right Lever Press Figure 3 14 Edit Selected Targets Window Configure the Endpoints Timeout Table The timeout table is required to set the protocol timeout In the Edit Database Template window click on the Add button select the Endpoints Timeout Table entry in the list and click on the OK button Click on the Edit button to display the empty timeout table Add one entry to the table by clicking on the Add button then adjust this entry to 20 minutes using the Edit button Using a timeout table with a single entry means that this entry will be used by the protocol manager by default if we define a timeout table with more than one entry then during the loading of a session the entries in the timeout table will be presented to the operator who has to select the appropriate value to use as the timeout for the session K Limbic Developers Guide Tutorial Guide 39 Edit Endpoint Counts Comment 100 Trials Endpoints Enable Endpoint Trials All M Trials
86. ing index tone burst duration x2mS and the hold time centiseconds for each trial The Group entry 0 in all Table Mode auto controls otherwise the Group entry is set to the table index of the current parameter set Auto Control Data sections vary for each type of auto control if in any doubt as to the content of this section please contact Conclusive Solutions kK Limbic Developers Guide Output File Format 118 Trials Data The trials data section lists the output reports from the stages All output files contain a trials data section The Trials data section commences with the Trials identifier then comes the output reports header that details the contents of each column Below the output reports header are the output reports themselves split into one row per trial The size of the trials data section depends on the number of output reports identified in the protocol definition and the number of trials performed during the session The first three columns of the data are always Trial Ref The index number of the trial Outcome A numerical value identifying the trial Outcome see below Item Index The index into the auto control used for the trial The remaining columns are determined by the stage reports settings in the protocol The Trial Ref is a zero based index of the trial number The Item Index is generally the same as the Trial Ref it is the index into th
87. ingle entry the entry specifies the pulse duration for the pellet dispenser set this value to 100mS Dosing List Set the dosing list to be appropriate for training the animals i e a single No Dose entry It is possible to pre define the dosing list but probably not worth doing so here If the Dosing List contains a single entry then that entry automatically becomes the value that will appear in the output data file default entry If the Dosing List contains a default entry K Limbic will not present the Dosing List to the operator during the session load process FR Parameters FR parameters specify a set of database parameters FR parameters may be present in the database as either a single FR entry or as a table of FR entries Using a table of entries is the preferred method The FR stage of the protocol uses the FR settings Selected Lever Parameters Using Selected Lever parameters provides a simple method of assigning a Target lever to a subject During the fixed ratio protocol a single lever is presented to the animal The Selected Lever parameters determine whether this is the left or right lever It is recommended that the database be arranged so that in any given chamber the left lever is used half the time and the right lever used for the other half this is easy to organise by suitable manipulation of the Selected Lever settings Endpoints Timeout Table Define an Endpoint Timeout Table with a single en
88. ion through a VI stage or an Interval stage If all values in the table have been used the table wraps around to the beginning K Limbic Developers Guide Auto Control Reference 64 Edit VI Parameters Variable Interval V1 Figure 4 2 VI Parameters Random Variable Interval kK Limbic Developers Guide Auto Control Reference 65 4 3 The VI FR Auto Control A VI FR auto control is built using VI FR parameters from the subject database The VI FR auto control is a combination or a variable interval auto control and a fixed ratio auto control VI FR Parameters are available in the database under the following parameter types e VI FR Table e VI FR Parameters For a description of the variable interval auto control and the fixed ratio auto control refer to the sections on these types of auto control Edit VI FR Parameters Comment i80 FR 10 Entry Index 1 VI FR Details Edit FR Parameters OK Cancel Figure 4 3 VI FR Parameters K Limbic Developers Guide Auto Control Reference 66 4 4 The Delay Table Auto Control A Delay Table auto control is built using a Delay Table from the subject database The Delay Table parameters are the only applicable parameters in the subject database A Delay Table is a list of user specified delays The table may contain an arbitrary number of entries The operator selects an entry from the table for each box during the load session procedure The selecte
89. is OK Click on the Next button at the bottom of the window Step 6 of 6 Message Filter The Message Filter should be enabled for this protocol so ensure this option is checked in step 6 Enabling the Message Filter instructs the system not to send messages sent when a sensor is released In the fixed ratio protocol we are not interested in when the lever is released or when the animal exits the pellet receptacle so we can ignore sensor releases The Message Filter has no effect in the Med Associates version of K Limbic Click on the Finish button at the bottom of the window The settings for the initial stage are complete so the wizard closes and the new stage is added to the Configured Stages list the list should now display Stage 1 Start indicating that the stage list contains the first stage we have defined kK Limbic Developers Guide Tutorial Guide 22 Add the Fixed Ratio stage The Fixed Ratio stage is of the type Fixed Ratio The fixed ratio stage e Extends the target lever e lluminates the cue light above the lever e lluminates the house light e Leaves the magazine light unchanged The fixed ratio schedule the number of times the subject must respond before receiving a reward is not fixed as part of the protocol a more flexible approach is used Prior to the start of the current trial the protocol manager interrogates the subject database to determine the a
90. itle at the top of the wizard should display Step 1 of 2 Trial Marker Actions The Stage entry just below the title displays Mark Trial Set Outcome delete this entry and enter Correct Trial instead In the Trial Control section select the Increment Trial option In the Trial Outcome list select the Correct Trial entry Click on the Next button at the bottom of the window Step 2 of 2 Display Message We do not wish to send a message to the screen display at this time so this step is OK Click on the Finish button at the bottom of the window Add the Pellet Collected stage The Pellet Collected stage is of the type Shadow Stage The Pellet Collected stage e Turns off the magazine light In general any stage of the protocol defines a specific state for each of the resources in the chamber In some cases it is useful to change the state of one or more of the resources during a stage an example of this is turning off the magazine light when the subject collects a delivered pellet a shadow stage is used for this purpose The shadow stage is activated by a response on the Shadow Trigger of the current stage when the subject activates the shadow trigger the operant chamber is set to the state defined by the shadow stage Select the stage type Shadow Stage in the Available Stages list and click on the Build Stage button The Stage Wizard
91. ivity log is split into trials as per the protocol The activity log can contain an arbitrary number of reports each row of data can contain up to 250 reports each report appears in a single Excel cell Trial zero is the Start stage i e before the protocol begins this log will not contain any useful reports it just confirms that the Start stage stage type Initial Stage was used prior to the protocol start Trial 1 is the first trial in the session it will contain all activity reports generated in the trial The DATA identifier appears in column A followed by a row of up to 250 activity reports if more than 250 activity reports were generated during the trial the log wraps onto the next row The final activity report in the trial is followed by the EOD identifier The end of the activity log section is marked by the END identifier Activity log reports The activity log can contain the following reports Start of session report Report appears once per session and will always be as below 2000 PS 0 End of session report Report to mark the end of the session 2001 PE 180000 The 180000 value is the time at which the session ended in centiseconds 30 minutes Response Activated Report generated each time a sensor is activated 2002 0N 1 S 0 7685 The value 1 is the index of the current stage The index is zero based thus stage 1 is reported as 0 stage 2 is reported as 1 etc
92. l Yogel Drinking Measurement Habituation amp Test Day 203420 Cued Serial Reversal Cued Serial Reversal 240600 1 Timed pellet Delivery Timed Pellet Delivery Conflict 101 PR 101 Progressive Ratio Progressive Ratio Pen nee eee Mee ae TA ERRET ETA Edit Header New Test Suite Build Test Suite Edit Test Suite Create Copy Delete Test Suite Figure 3 9 Test Suite Manager Window The window contains two tabbed pages one page for Development Test Suites the other for Installed Test Suites select the Development Test Suite page The Development Test Suite page contains a list of the Development Test Suites installed for the current user Below the list of Test Suites are a number of buttons used to perform a variety of actions Click on the New Test Suite button this presents a window asking you enter the Reference Title and Description for the new test suite Each of these entries are user defined so you can enter whatever you like for these entries although the Reference entry must be unique For Development test suites tend to use a descriptive value so suggested entries are as follows K Limbic Developers Guide Tutorial Guide 32 Header Details For New Test Suite m Header Details Reference Fixed Ratio 101 Title Fired Ratio Test Suite Description Development Test Suite Cancel Figure 3 10 Test Suite Header Details Click
93. less than 1 5 seconds so using a standard fixed ratio stage results in some triggers of the reinforcer being ignored If a fixed ratio meted stage is used instead and a metering period of 2 seconds is specified then there is minimum period of 2 seconds between entry to the stage and exit from the stage so no reinforcement triggers will be ignored Responses are accumulated so any excess licks count towards the next reinforcement in the case above with a fixed ratio of 20 and a metering period of 2 seconds if the subject records 25 licks during the 2 second period then 5 licks will be carried over to the next ratio count k Limbic Developers Guide Stage Type Reference 95 5 2 8 Variable Interval Stage Components Driver Controls Display Message Target Dummy Settings Stage Exit Triggers Interval Controls Stage Reports Function A Variable Interval stage provides a period sub divided into smaller random intervals Variable intervals are used commonly in operant tasks where it is desirable to encourage a subject to respond at a high rate The variable interval settings are specified by the variable interval parameters of the subject database A VI stage contains stage timeout exit triggers and an end of interval trigger The developer specifies the end of interval trigger to occur either immediately the interval timeout occurs Trigger On Interval or on the first response that occurs after the inte
94. lever assuming your chamber contains two levers To reassign the target lever we only need to edit the selected lever parameter entry rather than edit each of the entries in the FR table for each subject The section on populating the subject database later on gives details on how this is done efficiently Click on the Add button and in the Select Parameter Set list select the Selected Lever entry then click on the OK button A Selected Lever parameter is added to the parameter list Click on the Edit button to display the Edit Selected Targets window the window contains two tabbed pages one for the Selected Lever and one for the Selected Sensor Here we want to assign the selected lever In the Target Assignments section set the Control Target and Active Target settings to Left Lever Press and in the Dummy Assignments section set the Control Dummy and Active Dummy settings to None as shown in fig 3 9 below The Control Target setting is used as the target when a dose type of Inactive is assigned to the subject The Active Target setting is used when a dose type of Active is assigned to a subject Having dose dependent target dummy levers is important when performing drug discrimination studies which is not important here kK Limbic Developers Guide Tutorial Guide 38 We have set both of these to the same lever so the target lever is
95. llows the sequence A full discussion of the cued lever serial reversal task is included in the protocol description document for the cued lever task in the K Limbic repository K Limbic Developers Guide Auto Control Reference 83 4 14 The DRL Auto Control A DRL auto control is built using DRL parameters from the subject database The DRL parameters are available as a DRL Table the table can contain an arbitrary number of DRL parameter entries The operator selects one entry from the table during the load session procedure The DRL auto control is intended for use in DRL delayed reinforcement to lever tests The settings of the CRL auto control are accessed from DRL stages in the protocol Edit DRL Parameters Comment DRL 72 Trials Delay Iterations 10 Hours Mins Secs v alo for fre Bank Size p 10 v RAE 7 Banked Trial Timeou V Enable Peak Trials Hours Mins Secs foo fo foo Trials 100 Figure 4 14 DRL Parameters The DRL auto control generates a list of trials for each trial the control generates a Delay and a Trial Timeout the values of these parameters are specified by the user The number of trials generated is determined by the Iterations amp Bank Size parameters A peak trial is one in which the Delay value is indefinite if Peak trials are enabled then one trial per bank will be a peak trial the peak trial is randomly presented If
96. ludes a light in the pellet receptacle A reward stage in the protocol turns on the light in the pellet receptacle to signal that the pellet is there the protocol then enters the next stage an FR stage for example In the FR stage the head entry detector on the pellet receptacle is assigned as the shadow trigger when the subject collects the pellet this triggers the shadow stage The shadow stage defines the state of the receptacle light as Off so collecting the pellet triggers the protocol to turn off the receptacle light the protocol continues with the FR stage k Limbic Developers Guide Stage Type Reference 97 5 2 10 Timer Stage Components Driver Controls Display Message Target Dummy Settings Stage Exit Triggers Stage Reports Function A Timer stage is used in situations where the protocol needs to record the time a sensor is active The stage assigns a sensor as the target sensor and an optional dummy sensor The stage records the time the sensor is active An optional Timeout On Target exit trigger provides the ability to exit the stage after the sensor has been active for a specified period A Timer stage is useful for monitoring the duration a subject is present in a particular location of the chamber at the drinking spout for example A protocol that uses any Timer stages should not enable the Message Filter see the Initial stage description k Limbic Developers Gu
97. ment stage The stage is used to mark the outcome of a trial e g Correct Incorrect Missed etc An Outcome stage is instantaneous although there is a finite time taken to process an Outcome stage this time is very short and unperceivable by the subject A protocol can use an outcome stage to mark the performance of a trial The flow of a protocol will vary depending on whether a subject performs the trial correctly incorrectly or not at all etc the protocol can contain multiple outcome stages at different points in the protocol to mark the performance of the subject A Mark Trial Set Outcome stage also performs this function but it also affects the trial count An example of the use of Outcome stages is the DMTP protocol where the trial performance is either correct incorrect or missed The DMTP protocol uses three outcome stages at various points to mark the trial as one of the tree options The Increment Trial stage a Mark Trial Set Outcome stage then simply increments the trial count without making any changes to the stage outcome A protocol should be arranged so that each trial passes through one stage that sets the outcome per trial i e the protocol flow should not pass through an Outcome stage that say sets the trial outcome then later in the same trial passes through a second Outcome stage kK Limbic Developers Guide Stage Type Reference 11
98. mp Run A K Limbic Experiment Check The User Profile Importing Your Protocols Create A Development Test Suite Build An Installed Test Suite Prepare The Test Suite For Use How To Load amp Run A K Limbic Session What Happens During An Experiment Ending A Session Prematurely What Happens At The End Of A Session 3 10 Loading The Conflict Session 4 Managing Data 4 1 4 2 Data Files Explained Automated Analysis kK Limbic Developers Guide Introduction 1 Section 1 Introduction K Limbic is a PC based system for the control of animal behavioural experiments Designed in collaboration with several international pharmaceutical companies K Limbic has developed into a versatile flexible and powerful tool for performing behavioural experiments The major component in the K Limbic system is the integrated development environment IDE The IDE provides all the tools required to develop edit and run your operant experiments K Limbic provides a protocol manager to generate edit and share experimental protocols a database manager to create databases with subject details and a run manager to run experiments Behavioural experiments use a variety of techniques for selecting experimental parameters such as stimuli time delays and reinforcement regimes typical examples of such techniques are fixed ratios variable intervals and matched and non matched to position delay values Historically the application of these param
99. mplate window Configure the FR Parameters The fixed ratio protocol requires the database to define a value for the fixed ratio parameters The database contains several options for providing FR parameters any of which may be used e g a single FR Parameters entry a table of FR entries a combined VI FR entry or a table of VI FR entries The most useful of these for the fixed ratio protocol is the table of FR entries A table of FR entries normally defines a list of fixed ratios of gradually increasing difficulty as the subject gains experience of the task the operator can assign more difficult ratios up to the maximum value required for the task Click on the Add button and in the Select Parameter Set list select the FR Table entry then click on the OK button An FR Table parameter is added to the parameter list Click on the Edit button to display the Edit Parameter Table window the initial FR Table has a single entry click on the Edit button to display the FR parameters We will set this entry to define a fixed ratio that creates an FR10 on a single lever the target lever The target lever will be assigned using a Selected Lever entry in the database 1 Change the Comment entry to a meaningful value e g FR10 2 Change the Ratio value to 10 using the up down buttons or simply type 10 in the box 3 Change the Target setting to Use Selected Lever this dis
100. n brief the task consists of presenting both levers to the subject and illuminating the cue light above one of the levers the subject must learn to respond on one lever either cued or un cued to receive a reward after completing a given number of trials the task changes and the subject must learn to switch to the opposite lever either un cued or cued The cued lever parameters support tasks where the target lever changes during the session on a trial by trial basis or where the target lever remains constant within a session but varies from one session to the next The sequence of target levers may be preset or random as specified by the Sequence Control parameter eight normalised sequences are provided and four training sequences kK Limbic Developers Guide Auto Control Reference 82 The cue lights are controlled by the Cue Control parameter of the auto control and the Task Control parameter of the Cued Lever stage Cue Control Task Control Effect on Cue Light Standard Standard Illuminate above target lever Standard Reverse Illuminate above dummy lever Reverse Standard Illuminate above dummy lever Reverse Reverse Illuminate above target lever None na Both cue lights off Both na Both cue lights on For protocols that vary the cue from session to session it is possible to instruct the protocol manager to store the current settings in the cued lever parameters so that on the next session the cue control fo
101. ng lists is not essential to running K Limbic but they can be used to save a lot of time when it comes to analysing data The Parameters List stores a collection of protocol specific parameters such as FR schedules five choice parameters delay values etc The parameter values are used to customise a given protocol for a specific subject Refer to the documentation on your protocol to determine which database parameters are required for your protocol kK Limbic Developers Guide Tutorial Guide 9 Section 3 Tutorial Guide Create A Simple Protocol The following section is a step by step guide on how to create a K Limbic protocol If K Limbic has not been installed on the machine you are using refer to the installation and configuration instructions in the K Limbic Installation amp Configuration Manual separate document This guide assumes that you have followed the instructions detailed in the K Limbic Installation amp Configuration Manual The instructions here detail the actions required to perform Option 3 in the What To Do Next section of that manual K Limbic supports a number of approaches to creating protocols for instance e Importing an existing protocol e Copy and edit an existing protocol e Create a new protocol from scratch In many cases and not wishing to reinvent the wheel importing existing protocols is the way to go perhaps combined with a bit of editing for individual preferen
102. nto K Limbic for new or novel protocols may appear disadvantageous however once added the new stage types do not need to be added in again by other experimenters so in the global sense this saves an enormous amount of time Please remember Conclusive guarantee that we will not charge for making additions to K Limbic for any currently supported K Limbic system kK Limbic Developers Guide Software Overview 8 2 6 Subject Databases Overview K Limbic provides a database utility for the storage of experiment parameters that are unique to individual subjects Database parameters are central to the use of K Limbic and are closely linked with protocol definitions Database parameters interact with the protocol definition to create an experiment customised to the individual subject A subject database may store information on a very large number of subjects i e in excess of 1000 however it is recommended that databases are organised on a study basis i e if a particular study consists of 64 subjects then create a separate database for these subjects K Limbic can support any number of databases Databases are stored within installed test suite files It is possible to maintain an arbitrary number of test suites on a K Limbic system the number and size being restricted by the available storage space on most modern computers the space available is so large that it can be considered that an unlimited number of test suites can be supported K
103. ocol exits the FR stage passes through a reward stage to trigger the pellet dispenser and then loops back and re enters the FR stage The sequence of fixed ratio complete reward delivery may be repeated many times during the five minute period at the end of the 5 minutes the stage exits via the stage timeout exit trigger and moves on to another part of the protocol kK Limbic Developers Guide Stage Type Reference 94 5 2 7 Fixed Ratio Meted Stage Components Driver Controls Display Message Stage Exit Triggers FR Controls Stage Reports Function A Fixed Ratio Meted stage is an adapted fixed ratio stage intended for situations where the rate of reinforcement must be limited Protocols in which the rate of drug delivery is dependent on the rate of responding sometimes require the protocol to limit the rate of drug delivery A fixed ratio meted stage exhibits the same behaviour as a standard fixed ratio stage but adds ina Metering Period the metering period is the minimum period between successive triggers of the end of the stage this is usually the same as the period between reinforcements Consider a protocol that counts licks and delivers a reward on every 20 lick The reward mechanism takes 1 5 seconds to deliver the reinforcement and does not respond to a trigger that occurs before the end of the current delivery In practise it is found that the subjects are able to produce 20 licks in
104. of the auto control section should be self explanatory The Index field is the index from the database of the chosen parameters 0 if the entry was not selected from a database table The AC Comment is the comment field from the database parameters The auto control data on the Individual Subject page of the example file is for a fixed ratio type auto control this is a relatively simple report that records the FR schedule the target index the dummy index the Reset on Dummy value the Disable Unused value amp the Enable Rewards value The auto control data on the Auto Control Data illustrates the auto control data section for a 100 trial five choice experiment The Choice Details fields record the index of the selected parameters from the five choice table same as the Index field above the Sensors field records the number of active sensors e g 5 The Iterations field records the value of the Iterations field from the database The banked field 1 if banking is enabled 0 if banking is disabled The Trials field records the number of trials in the auto control normally the maximum number of trials in the session Following the choice details are the trial details The trial details contain 100 columns 1 per trial that list the bank group stimulus duration centi seconds channel number intensity inter trial interval centi seconds tone tim
105. on Load The Test Suite From the K Limbic main menu select File Load Test Suite or press function key F2 This will present the Load Test Suite window the window contains a list of all the Installed Test Suites available to the current user Load Test Suite Test Suites 375001 Vogel Sessions In Selected Test Suite 500 01 Fixed Ratio Session 5CSATT 1 Nathalie Cancel 203420 Test CER Test 240600 Test Conflict 101 373003 Five Choice SD 373003 Five Choice SD ITI Progressive Ratio MAT O1 NB 373003 Conflict Test Suite Variable ITI Task Conflict T101 Fixed Ratio Test Suite Figure 3 26 Load Test Suite Window Select the Fixed Ratio Test Suite and click on OK K Limbic loads the Fixed Ratio Test Suite Load The Fixed Ratio Session From the K Limbic main menu select Session Load Session This will present the Select Session window The window contains a list of the sessions in the Fixed Ratio Test Suite see figure 3 26 Select the Fixed Ratio Session and click on OK see figure 3 27 K Limbic is now ready to assign subjects to chambers The Database Select Subject window appears it is prompting you to select the subject that will be placed in Box 1 by default the first subject in the list is selected K Limbic remembers the assignment of subjects to chambers and will automatically select the most appropriate subject next time around
106. otocol In the Source Stage list select the Correct Trial stage the destinations list updates to display two entries Set the destinations as below e Continue Fixed Ratio e Trials Complete Exit This completes the process for the Dispense Pellet stage Normally passing through the Correct Trial stage returns the protocol to the Fixed Ratio stage however if a maximum number of trials is specified in the Counts endpoint then the protocol will pass to the Exit stage thus ending the protocol The Pellet Collected stage and the Exit stage have no valid destinations therefore the process component is now complete Click on the OK button to close the Configure Process window kK Limbic Developers Guide Tutorial Guide 29 The Auto Parameters Component The auto parameters component determines which type of Auto Control the protocol manager builds for use during the protocol In general the Auto Control is a list of experiment specific values used by the protocol manager to customise a generic protocol to a specific subject A range of auto controls is available some are specific to types of experiment such as the CER amp DMTP controls and some are more general such as the fixed ratio amp VI controls The Auto Control type determines which parameters are required in the subject database the required parameters appear in the list below the auto control type The fixed r
107. otocol i e the state of the chamber as the animal is placed into the chamber Select the stage type Initial Stage in the Available Stages list and click on the Build Stage button The Stage Wizard appears this is a series of windows that prompts the user to select the appropriate settings for each stage In the case of the Initial Stage the title at the top of the wizard should display Step 1 of 6 Lever Positions In our case we want the levers to be retracted and all lights off the default values of the Start stage are therefore pretty much appropriate The Stage entry just below the title displays Initial Stage delete this entry and enter Start instead kK Limbic Developers Guide Tutorial Guide 21 By default the levers are retracted so step 1 is OK Click on the Next button at the bottom of the window Step 2 of 6 Cue Light States By default the cue lights are off so step 2 is OK Click on the Next button at the bottom of the window Step 3 of 6 Enclosure Light States By default the enclosure lights are off so step 3 is OK Click on the Next button at the bottom of the window Step 4 of 6 Display Message We do not wish to send a message to the screen display at this time so step 4 is OK Click on the Next button at the bottom of the window Step 5 of 6 Target Dummy Settings There are no Target Dummy resources required at this time so step 5
108. ow we can use this to build as many Installed Test Suites as we need The organisation of Installed Test Suites is up to the individual user however Conclusive recommend a one to one relationship between Installed Test Suites and groups of animals For instance if your lab will run one squad of animals in the mornings and a different squad of animals in the afternoons then it is a good idea to have two Installed Test Suites one for each squad but it is up to the user Of course over time you will probably develop several protocols and hence have a collection of test suites With the Fixed Ratio 101 development test suite selected click on the Build Test Suite button this presents the Build Test Suite window The header details of the Fixed Ratio 101 development test suite are shown in the top section of the window and any installed test suites are listed in the lower section If this is a new installation of K Limbic this list will initially be empty Build Test Suite Source Test Suite Reference Fixed Ratio 101 Title Fixed Ratio Test Suite Description Development Test Suite Installed Test Suites Eh CMLO02 4 Box Test DMTP Test DMTP Training TT 01 GoNogo 01 CMLOO3 FR Test 373003 Five Choice 373005 e eee af ove fo ove ao eve of vee fo ove af vve alo eve of ave af coe of Figure 3 18 Build Test Suite Window kK Limbic Develope
109. peak trial has a delay period of 6 minutes in K Limbic the delay phase of a peak trial normally lasts for the entire duration of the DRL stage If peak trials are enabled then each bank of trials will include one peak trial For an example of the use of DRL stages refer to the K Limbic repository k Limbic Developers Guide Stage Type Reference 113 5 2 25 Timeout Stage Components e Driver Controls e Display Message e Stage Exit Triggers e Stage Reports Function A Timeout stage is provides a flexible method of providing a database dependent timeout period In many behavioural tests it is necessary to react to an incorrect or unwanted response by sending the protocol into a timeout period i e a period in which the protocol pauses before continuing Any stage type can be used to provide a timeout period simply by setting the driver controls to the appropriate values and enabling one of the stage timeout endpoints e g Action stages can easily be used for this purpose using a fixed timeout endpoint Timeout stages have the advantage that the timeout value can be specified by the Auto Timeout parameters of the subject database Using the subject database provides flexible setting of the timeout period without the requirement to change the protocol definition The stage sets the state of the operant chamber then waits for the timeout period k Limbic Developers Guide Stage Type Reference 114 5 2
110. ppropriate fixed ratio to use during this stage The fixed ratio is therefore subject dependent Select the stage type Fixed Ratio in the Available Stages list and click on the Build Stage button The Stage Wizard appears the title at the top of the wizard should display Step 1 of 7 Lever Positions We want the lever to extend during this stage but only if it is the target lever more about target levers shortly In the Left Lever tab click the Extend If Target option then select the Right Lever tab and click the Extend If Target option Click on the Next button at the bottom of the window Step 2 of 7 Cue Light States We want the light above the extended lever to come on during this stage In the Left Cue Light tab click on the On If Target option then select the Right Cue Light tab and click the On If Target option Click on the Next button at the bottom of the window Step 3 of 7 Enclosure Light States We want the house light to be on throughout this stage In the House Light tab click the On option Select the Magazine Light tab The magazine light is turned on when a pellet is dispensed and remains on until the pellet is collected thus the fixed ratio stage does not directly control the state of the magazine light click on the No Change option for the magazine light Click on the Next button at the bo
111. protocol both the Target and Dummy are enabled if a dummy is used If the Dummy As Target option is active then the ratio is complete when either count reaches FRn If the Disable Unused Lever option is active then the when the first fixed ratio is complete the lever that did not register FRn responses is disabled and will not trigger a ratio complete endpoint K Limbic Developers Guide Auto Control Reference 63 4 2 The Variable Interval Auto Control A variable interval auto control is built using VI parameters from the subject database The variable interval auto control consists of a list of variable intervals The values held in a variable interval control are used by VI stages and or Interval stages in the protocol VI Parameters are available in the database under the following parameter types e VI Table VI Parameters VI FR Table VI FR Parameters Variable intervals in two categories are available they may be a table of random intervals or a table of specified values In random mode the database specifies a mean value a delta value and a table length value N The auto control builds a list of N variable intervals where each interval falls randomly in the range Mean Delta lt VI lt Mean Delta In interval mode the operator builds a table of delay values The table can contain any number of entries A new value from the list of variable intervals is used with each iterat
112. rd stage The Dispense Reward stage is of the type Reward Stage The Dispense Reward stage e Triggers a pellet delivery it does not wait for the pellet to be delivered or check that delivery has occurred e Turns on the magazine light Select the stage type Reward Stage in the Available Stages list and click on the Build Stage button The Stage Wizard appears the title at the top of the wizard should display Step 1 of 7 Rewards and Shocks The Stage entry just below the title displays Reward Stage delete this entry and enter Dispense Pellet instead We want to trigger the pellet dispenser so click on the Dispense option Leave the Reward Table section unchanged Click on the Next button at the bottom of the window Step 2 of 7 Lever Positions By default the lever controls are set to No Change this is OK Click on the Next button at the bottom of the window Step 3 of 7 Cue Light States By default the cue light controls are set to No Change this is OK Click on the Next button at the bottom of the window Step 4 of 7 Enclosure Light States By default the enclosure light controls are set to No Change this is OK for the house light but not for the magazine light Click on the Magazine Light tab and change the setting to On Click on the Next button at the bottom of the window Step 5 of 7 Display Mess
113. rs Guide Tutorial Guide 44 Click on the Build Test Suite button A window appears prompting for header details of the new Installed Test Suite the entries here are up to the user but the following entries are suggested Header Details For New Test Suite Header Details Reference Fixed Ratio Test Suite Description Training Sessiorl OK Cancel Figure 3 19 New Test Suite Details Window These values are not cast in stone you can change them later if desired Click on the OK button this opens what is called the Repository Manager which builds the Installed Test Suite If everything builds successfully then no errors are reported click on the OK button to close the Repository Manager then click on OK to close the information window that appears The Fixed Ratio Test Suite appears in the list of Installed Test Suites Click on the OK button to close the Build Test Suite window Click on the Exit button to close the Test Suite manager The User Details section of the main screen will update to show the Fixed Ratio Test Suite with its two sessions in the Installed Test Suites list kK Limbic Developers Guide Tutorial Guide 45 3 5 Prepare The Test Suite For Use The final stage of configuration before we are ready to run an experiment is to prepare the newly installed test suite Once this is complete the Sessions in the Installed Te
114. rval timeout Wait For Target A VI stage may be iterated looped many times during the same trial The stage timeout begins on the first entry to the VI stage in any one trial it is not reset on subsequent entries to the stage during the same trial This allows the protocol to define a VI phase of a specified length Consider a VI stage with a fixed timeout of 5 minutes each time the end of interval exit is triggered the protocol exits the VI stage passes through a reward stage to trigger the pellet dispenser and then loops back and re enters the VI stage The sequence of interval complete reward delivery may be repeated many times during the five minute period at the end of the 5 minutes the stage exits via the stage timeout exit trigger and moves on to another part of the protocol k Limbic Developers Guide Stage Type Reference 96 5 2 9 Shadow Stage Components e Driver Controls e Display Message e Stage Reports Function A Shadow stage provides a secondary state of the operant chamber The Stage Exit Triggers of many stage types include a Shadow Trigger any sensor in the resource list may be assigned as the shadow trigger If the subject activates the shadow trigger in any stage the protocol resets the state of the operant chamber to the state defined in the Shadow stage but continues with the current stage A common example of the use of a shadow stage consider an operant chamber that inc
115. ry sensor in the pellet receptacle The list should contain an entry for each resource that will be used in the protocol for the case of the fixed ratio protocol the default list is OK however it is simple to add delete edit the entries in the Resources list as will now be shown Click on the Edit Resources button this will display the Configure Resources window The window contains the list of configured resources and a list of all available resources With the Left Lever entry highlighted in the Configured Resources list click on the Edit Resource button The Edit Resource window appears Resource Type The window shows that this resource is Lever Control lt 1 gt i e it is the first resource in the list that is a Lever Control resource lever control resources control the position of retractable levers The Resource Type is not editable If you do not want a resource of a particular type it should be deleted from the list Resource Description The Resource Description is a user defined field used as the screen identifier for this resource at present this is set to Left Lever but it may be changed to any value that the user prefers Class The class of the resource determines whether the resource is controlled by K Limbic or whether it signals a response from the animal In general items controlled by K Limbic should be assigned as class Driver however the stimulus lights in
116. s Standard Target Right Lever Reverse Target Left Lever Standard Dummy Left Lever Reverse Dummy Right Lever The random lever auto control can cater for up to four levers The assignments of the random lever auto control are useable in any stage where it is possible to set the Target or Dummy to the Standard Auto or Reverse Auto settings Edit Iteration Parameters Iteration Parameters ym V Banked Cancel Figure 4 5 Iteration Parameters kK Limbic Developers Guide Auto Control Reference 68 4 6 The One Choice Auto Control A One Choice auto control is built using a One Choice Table database parameter The one choice auto control is specifically intended for protocols implementing the one choice serial reaction time task The one choice serial reaction time task is a simplified version of the five choice task where only one stimulus light is used instead of all five The one choice task can be used as a training task for the full five choice task A one choice table parameter is a database table that can hold an arbitrary number of entries The table can be used in either Table mode or Series mode Each entry in the table specifies the following entries Stimulus Parameters Duration Duration of the stimulus flash Intensity Intensity of the stimulus Limited Hold Time allowed for response to stimulus Active Channel The index of the active stimulus light Control Parameters Iterations
117. s in turn until you have created the required experiment The details of this tutorial guide are intended not as a protocol guide but as a guide to the process of creating and editing K Limbic protocols It is always a good idea to illustrate your experiment with a flow chart such as the one in figure 3 4 using the available stage types as the building blocks of your protocol If you can display the protocol as a flowchart it is probable that you can create your protocol If however the available stage types do not cater for your experiment help is at hand Contact Conclusive Solutions and we will be happy to discuss your requirements and extend the capabilities of K Limbic so that you are able to perform your experiment there s nothing we like better than adding new facilities to K Limbic Sections 4 amp 5 are a reference to the available stage types and auto controls in K Limbic Section 4 lists each auto control type and discusses the uses and functions of each type or control Section 5 lists each stage type and discusses the uses and functions of each type of stage Using the procedure outlined in section 3 and the available facilities detailed in sections 4 amp 5 we hope that you will be able to proceed with defining the protocol that you require Before you start writing your own protocol however please refer to the K Limbic repository on your installation CD it may well be that there is already a protocol that you can edit to sui
118. s individually is recommended if you name your subjects with individual names e g John Paul George amp Ringo Adding subjects automatically is recommended if you name your subjects numerically e g 1 2 3 4 etc In the lower section the prefix and suffix entries allow you to customise the automatic names e g A1 A2 A3 A4 etc or 1D 2D 3D 4D etc or even A1F A2F A3F A4F etc simply set up the prefix and suffix values as required Set the Subjects To Add value to the number of animals in your squad i e 64 check that the Use Template option in the lower section is checked then click on the Add Subjects button this will create a database of 64 animals each with their own set of parameters equal to those present in the Database Template The values in the Database Template are copied into the individual subjects as part of the creation process these parameter values are now stored in each subject If you now make a change to the Database Template the changes will not automatically be copied into the subjects more on this next Click on the OK button to return to the Database Maintenance window kK Limbic Developers Guide Tutorial Guide 47 Adjusting The Database Parameters This section is optional Those of you who have followed things so far might be thinking Hey what about the Target lever If the Selected Lever parameters in all subjects are the same then
119. ssignment Controls which sensor is considered the dummy Enable Reset Reset the count if a response is made on the Dummy Enable Rewards Enable Disable rewards after the iteration is complete Disable Unused Lever If a target amp dummy are used then following the first iteration the lever or sensor that did not complete the iteration is disabled e Dummy As Target Consider the dummy sensor as a second target sensor Using an FR auto control to determine these values as opposed to setting them directly in the protocol means that all of these values become subject and or session dependent Return To The Header Component The protocol is now complete but before we close the protocol editor it is useful to return to examine the Header component Click on the icon labelled Header the right hand side displays the current protocol header the list of stage reports and the list of required parameters Examine the lists to check that the entries below are displayed Stage Output Reports The settings of the stage component specified that the fixed ratio stage generate six stage reports a list of the reports is displayed in the Stage Output Reports list Required Parameters The Required Parameters list contains the FR Parameters entry used for the auto control component and two entries for the endpoints component Endpoints Timeout Table and Endpoints Counts Table kK Limbic Developers Guid
120. ssion of the use of the five choice auto control please refer to the protocol description documents of any of the five choice serial reaction time task protocols held in the K Limbic repository Edit Serial Choice Parameters Comment V Automatic Comment Control Parameters Iterations Inter Trial Interval Active Channel 100 4 505 Nose Poke 1 C Nose Poke 2 Banked C Nose Poke 3 C Nose Poke 4 Nose Poke 5 Stimulus Parameters Control Parameters Tone Parameters Cancel Figure 4 6 2 One Choice Control Parameters kK Limbic Developers Guide Auto Control Reference 70 4 7 The Five Choice Auto Control A Five Choice auto control is built using a Five Choice Table database parameter The five choice auto control is specifically intended for protocols implementing the five choice serial reaction time task A five choice table parameter is a database table that can hold an arbitrary number of entries The table can be used in either Table mode or Series mode Each entry in the table specifies the following entries Stimulus Parameters Duration Duration of the stimulus flash Intensity Intensity of the stimulus Limited Hold Time allowed for response to stimulus Control Parameters Iterations Controls the number of trials Banking Controls the banking of trials Inter Trial Interval Duration of the ITI stage Tone Parameters Tone Burst Duration of the distraction tone burst Tone Timing Timing of the
121. st Suite will be ready to use for experiments Preparing the Installed Test Suite for use consists of the following steps e Populate The Subject Database e Configure The Sessions To prepare an Installed Test Suite we must first load the it into K Limbic From the K Limbic main menu select File Load Test Suite Or press function key F2 This will present the Load Test Suite window the window contains a list of all the Installed Test Suites available to the current user Select the appropriate Test Suite in the list and click on the OK button The Test Suite section of the main screen will update with the details of the new test suite Populate The Subject Database In this section will describe how to populate the subject database i e add in the animals that will be used with this test suite From the K Limbic main menu select Test Suites Database Maintenance This will present the Database Maintenance window The Database Maintenance window presents all databases defined for the Test Suite at present the Fixed Ratio Test Suite contains just the default empty database Database Maintenance Database Reference Template Fixed Ratio Database Edit Template Cancel OK Database Contents 64 Subjects Copy Tagged Parameters Add Database Add Subjects k Copy Database Current Subject m Edit Subject Parameters Selected Lever Endpoints Timeout
122. subject All data entries commence with this cell The KLIMBIC OUTPUT FILE and MS EXCEL FORMAT cells also appear in all data entries The System entry records the name of the K Limbic system that created the file The date entry records the date of the session The Box Index entry records the number of the box The ExptType entry 0 for a Control experiment amp 1 for an Active experiment this information is extracted from the dosing details The Session Title records the title of the session The Protocol Title records the title of the protocol The Protocol Description records the description field of the protocol The Analysis Ref records the reference of the automated analysis package used to analyse this data The Dose Details entry is followed underneath by the fields from the does details e g dose description pre dose period amp dose category The index value is the index of the selected dose in the dose table The Subject Id is the identifier of the subject The DB Ref is the reference of the database of the subject The Duration field is the total duration of the experiment in centi seconds The Pellet Count is the total of all pellets delivered during the experiment The Fluid Count is the total of all fluid rewards delivered during the experiment The Air Puff Count is the total of all air puffs delivered
123. t your requirements kK Limbic Developers Guide Auto Control Reference 60 Section 4 Auto Control Reference K Limbic protocols use auto controls to generate experiment specific variables The protocol manager checks which type of control is required prior to the start of a session extracts the required parameters from the database of the selected subject and builds the control values automatically The facilities provided by each auto control type range from selecting a delay value to building tables of trials for tasks such as DMTP or the five choice serial reaction time task Auto controls support a wide range of behavioural experiments The values held in the auto control are available for use by the stages during a protocol examples of this are given under the individual auto control types Table 4 1 Available Auto Controls Fixed Ratio FR Variable Interval VI VI FR Delay Table Random Lever One Choice Five Choice T Maze Constant T Maze Random Progressive Ratio DMTP Control Sequential Choice Cued Lever DRL CER kK Limbic Developers Guide Auto Control Reference 61 4 1 The Fixed Ratio Auto Control A fixed ratio auto control is built using FR parameters from the subject database The fixed ratio auto control consists of one or more fixed ratio controls The values held in a fixed ratio control are used by fixed ratio stages in the protocol FR Parameters are available in the database under the follo
124. tages required for the fixed ratio protocol so the Configure Stages window is complete Click on the OK button to close the window and return to the protocol editor kK Limbic Developers Guide Tutorial Guide 26 The Endpoints Component A protocol ends by either e The operator issuing an end of session command e The flow of the protocol sending the protocol to an Exit stage e A predefined endpoint condition is met Although it is quite feasible to require the operator to manually end the protocol by issuing an end of session command it is considered good practise to develop protocols that end automatically In some cases the flow of the protocol always takes the protocol to the Exit stage in such a case there is no need to define an endpoint condition However for any trials based test or a test that is designed to last for a specific period it is normal to define one or more endpoint conditions The protocol will end when any endpoint condition is met We discussed the protocol flowchart a little earlier and determined that the fixed ratio protocol will end after a predetermined amount of time In addition to this it is also useful to end the protocol after a maximum number of pellets have been delivered this prevents the animal receiving too many pellets on any given session which may have an effect on their motivation to perform the task on subsequent sessions Click on the icon
125. the stage a full interval is required otherwise if the stage is entered and then re entered the interval timer continues as if a stage exit did not occur If Reset Auto Control is active then on a new trial the sequence of interval values repeats useful where the variable interval control is specified as a table of delay values rather than as random variable intervals The variable interval settings are specified by the variable interval parameters of the subject database A VI stage contains stage timeout exit triggers and an end of interval trigger The developer specifies the end of interval trigger to occur either immediately the interval timeout occurs Trigger On Interval or on the first response that occurs after the interval timeout Wait For Target kK Limbic Developers Guide Stage Type Reference 104 A VI stage may be iterated looped many times during the same trial The stage timeout begins on the first entry to the VI stage in any one trial it is not reset on subsequent entries to the stage during the same trial This allows the protocol to define a VI phase of a specified length Consider a VI stage with a fixed timeout of 5 minutes each time the end of interval exit is triggered the protocol exits the VI stage passes through a reward stage to trigger the pellet dispenser and then loops back and re enters the VI stage The sequence of interval complete reward delivery may be repeated many times d
126. to Box 1 and the prompt moves on to the next box and so on until all boxes in the session have been assigned a subject It is possible to leave a box empty simply click on the Leave Box Empty button K Limbic now prepares the protocols to run in each box this includes setting the state of the operant chambers to the state defined in the Start stage of the protocol when this process is complete an information window appears telling you the session is ready to run click on the OK button to close this window The subjects should now be placed in the chambers ready for the experiment to start The screen that is now visible is the run time display The details are dependent on the Display Type selection part of the Session configuration The precise details will vary but the general display layout is constant see figure 3 30 K Limbic Developers Guide Tutorial Guide 57 D KAimbic Formerly Kestrel Control System jle Session Protocols Test Suites Configure Utilities za a uE Run Manager Ji sion Training S a naa as a Individual Boxes Chamber 1 Chamber2 Chamber 3 Chamber 4 Chamber 5 Chamber 6 Chamber 7 Chamber 8 i Chamber 1 Ready To Start p Details z z Ready To Start Subject 17 Dose No Dose Control FRO Ready To Start Fata r m 00o Ready To Start Protocol FR Training For Conflict i TiO Time 000000 oads To Stat Status Ready To Start Stage Initial Stage Ready To Start 2 Ready
127. to control options e Reset On Target If enabled then the timer of the current interval is reset when the subject activates the target resource e Reset On Dummy If enabled then the timer of the current interval is reset when the subject activates the dummy resource On exit of the stage the delay timer can be reset so that a new entry to the stage starts with the delay timer reset k Limbic Developers Guide Stage Type Reference 106 5 2 18 Progressive Ratio Stage Components e Driver Controls e Display Message e Target Dummy Settings e Stage Exit Triggers e Stage Reports Function A Progressive Ratio stage sets the state of the operant chamber then waits until a specified number of responses the fixed ratio are made on the target dummy sensor or a timeout occurs As the name implies each time a ratio is completed the target count for the next ratio increases the sequence of increasing ratio values is determined by the progressive ratio parameters of the subject database The stage timeout is reset on each entry to the stage even if the stage is iterated repeatedly in the same trial It is good practise to define progressive ratio protocols so that the trial is incremented after each successful completion of a ratio this will result in an output file with details of performance on each ratio on each row of the output file k Limbic Developers Guide Stage Type Reference 107 5 2 19 Cued Choice Stage
128. try the time set in this entry will be the maximum duration of the FR protocol 20 minutes Endpoints Counts Table Define an Endpoint Counts Table with a single entry set the Trials All value in this entry this will be the maximum number of trials in the FR protocol since one pellet is delivered per trial this also controls the number of pellets delivered 100 Configure The Database Template We will now configure the database template The K Limbic repository contains database files that you can import into the test suite however here we will generate the template details manually In the Configure Test Suite window click on the Configure Database Template button this presents the Edit Database Template window The Edit Database Template window displays the current details contained in the database template initially the Parameters section will display that the parameters list is empty Configure the Rewards click on the Edit Rewards button The default rewards list contains two entries one for a pellet dispenser and one as a trigger for the foot shock Click on the Foot Shock entry to select it and then click on the Delete button to delete it Click on the Dispense Pellet entry and click on the Edit button to display the Edit Reward Table The table has a single entry set by default to 100mS this is a suitable duration pulse to trigger the pellet dispenser cl
129. try is added to the endpoints list Click on the Add Endpoint Table button In the Select Endpoint Type list select Counts Database Dependent Click on the OK button The endpoint entry is added to the endpoints list Click on the OK button the Configure Endpoints window closes and the two endpoints are added to the protocol kK Limbic Developers Guide Tutorial Guide 28 The Process Component The process component determines the passage of the protocol from one stage to another i e it represents the arrows in the flow diagram We now set the process component to define which stage is entered when another stage ends Refer to the flowchart of figure 3 4 to see the flow from one stage to the next The procedure is to select a source stage identify each exit trigger in that stage and specify a destination stage for each trigger Click on the icon labelled Process the right hand side displays the current list of stages and the destinations for the triggers of each stage By default all destinations are undefined Click on the Edit Process button the Configure Process window displays The Source Stage section contains a list of the stages of the protocol and the destinations for the currently selected source stage The Destinations section contains a list of the stages of the protocol On entry to the Configure Process window the first stage in th
130. ttom of the window Step 4 of 7 Display Message We do not wish to send a message to the screen display at this time so step 4 is OK Click on the Next button at the bottom of the window Step 5 of 7 Stage Exit Triggers We want to remain in the fixed ratio stage until the fixed ratio is complete so ensure the Disable Timeout option is selected and the Exit When Ratio Complete On Target option is selected they will be by default When the subject collects the pellet we want to alter the state of the magazine light without exiting the fixed ratio stage this is achieved using a Shadow stage to change the state of the light A response on the Shadow Trigger triggers the shadow stage click on the Assign Shadow Trigger button on the right of the window select the Magazine Sensor entry in the list of resources and click on the OK button The Magazine Sensor is assigned as the shadow trigger for this stage Click on the Next button at the bottom of the window Step 6 of 7 FR Controls A protocol can contain several fixed ratio stages and each can use a different setting of fixed ratio a Fixed Ratio Series can be used for this however in this simple protocol there is a single fixed ratio stage which requires a single fixed ratio value therefore ensure the Single Entry option is selected as it will be by default Click on the Next button at the bottom of the window kK
131. types exhibit specialised behaviour the specialised behaviours are controlled by stage specific components these are discussed for each stage type The following sections list each stage type available in K Limbic and give an indication of the available functions k Limbic Developers Guide Stage Type Reference 88 5 2 1 Initial Stage Components e Driver Controls Display Message e e Target Dummy Settings e Message Filter Function An Initial Stage sets the state of the operant chamber prior to the start of the session In most cases the state specified in the Initial Stage is the state required when the animal is placed in the operant chamber The Initial Stage is active once the session is loaded when the operator starts the session the protocol manager exits the Initial Stage and enters the stage specified as the Continue destination of the Initial Stage All protocols require one stage of type Initial Stage by convention the Initial Stage appears as stage 1 in the stage list and is called Start The Initial Stage does not monitor the state of the sensors therefore it produces no output The Message Filter Enables disables sensor release messages from the hardware throughout the protocol If the Message Filter is enabled then the hardware reports when a sensor is activated but not when a sensor is released in many cases the experimenter is not interest
132. ue picked randomly from a specified range The enabling controls act as global controls throughout a protocol If shocks in the protocol are assigned as being in Shock Group A or Shock Group B then shock delivery is controlled by the auto control If the Tone setting in the protocol is set to On If Enabled then the auto control controls delivery of the tone If Cue Lights are disabled in the auto control then they are disabled in the protocol whatever setting in the protocol is used kK Limbic Developers Guide Auto Control Reference 85 Careful setting of the parameters of a CER table will result in on CER table that caters for all possible variants on the CER test from training through to test using a single protocol Edit Auto Timeout Parameters Comment 20 Minute Auto T imeout Timeout Mode Variable Interval Fixed Timeout Variable Interval m Mean Delta Hours Mins Secs Hours Mins Secs sio fo o ao e ae Cancel Figure 4 14 1 CER Auto Timeout Parameters A CER protocol uses a sequence of VI stages for full details refer to the CER protocol description in the K Limbic repository kK Limbic Developers Guide Stage Type Reference 86 Section 5 Stage Type Reference K Limbic provides a range of stage types to cater for various behavioural paradigms the range of stage types is listed in table 5 1 Experiment specific behaviour is included in some stag
133. ummy None C Left Lever Press C Right Lever Press Active Target C None C Left Lever Press Right Lever Press Active Dummy None C Left Lever Press C Right Lever Press Cancel Figure 3 22 Edit Selected Targets Window In the Target Assignments section select the Right Lever Press option for both the Control Target and Active Target settings Leave the Dummy Assignments as None Click on the OK button to return to the Edit Database Template window The settings in my version of the Edit Selected Targets window are not the same as shown above what is going on The options available in this window i e None Left Lever Press amp Right Lever Press are taken from the resource list stored in the active profile of the current user this is different from the resource list that was configured during the installation The default user contains an operant profile and a five choice profile each with their own resource list If the currently active profile is the Operant profile then the window should appear as shown however if the Five Choice profile is active there will only be the option None in the Edit Selected Targets window You will need to change the active user profile see section 3 1 The current active user profile is displayed in the status bar at the bottom of the K Limbic main screen the status bar displays the User
134. uring the five minute period at the end of the 5 minutes the stage exits via the stage timeout exit trigger and moves on to another part of the protocol For an example of the use of Interval stages refer to the Go Nogo protocol in the K Limbic repository kK Limbic Developers Guide Stage Type Reference 105 5 2 17 Delay Stage Components Driver Controls Display Message Target Dummy Settings Stage Exit Triggers Delay Controls Interval Controls Stage Reports Function A Delay stage provides a period sub divided into one or more Delays It is similar to an Interval stage with a fixed interval but the Delay value is specified in the subject database from a Delay Table A Delay stage lasts for a fixed period or for a specified number of iterations i e the number of loops through the stage The Delay timeout is either as specified using the Delay Table of the subject database or is a specified fixed delay value The Delay endpoint trigger either occurs immediately the delay timeout occurs or on the first activation of the target resource after the delay timeout The following delay endpoint options are available e Trigger On Delay Trigger the End Of Delay endpoint on the delay timeout e Trigger On Target Trigger the End Of Delay endpoint on the first activation of the target resource after the end of the delay The timing of the delays is subject
135. utorial section describes in detail the process for generating an example fixed ratio protocol Additionally the tutorial section runs through the process of creating a test suite that uses the protocol so that we can test the protocol in a live situation The process for creating the test suite is the same as discussed in the K Limbic Operators Manual The reference section lists the components available to build protocols stage types and auto control types The K Limbic repository contains a number of protocols available for use or as starting points for developing new protocols Each protocol in the repository includes a description document that details all the settings required to generate the protocol from scratch kK Limbic Developers Guide Software Overview Section 2 Software Overview 2 1 K Limbic Terms Resources Protocols amp Subject Databases As with all software applications K Limbic has its own vocabulary that is a collection of terms that are used in a specific manner This section provides a definition of the commonly used terms where their meaning is specific within K Limbic Resources A resource is any item of stimulus or response equipment placed within the animal chamber and connected to K Limbic Typical examples are lights levers position sensors etc Experimental environments e g animal chambers mazes etc are defined within K Limbic as a list of resources Protocols An individual e
136. verse targets levers or sensors Delays List of delays to be used Iterations Number of trial groups Banking Enable disable banking Matching Mode Match to position non match to position Repeat Incorrect Trials Enable disable repeated trials Repeat Missed Trials Enable disable repeated trials The DMTP control produces a table of trial settings used to control a DMTP experiment Standard Targets The Standard Targets list should contain one entry for each lever sensor that will be used as a Sample lever during the test For example in a lever based DMTP test the two levers will appear in the Standard Targets list Reverse Targets The Reverse Targets list should contain one entry for each lever sensor that will be used as a Reverse lever during the test For example in a lever based DMTP test if Lever lt 1 gt is the Standard lever then Lever lt 2 gt will be the Reverse Both levers are presented in the Choice stage of the test a response on the correct lever results in a reward The lists of standard and reverse targets can also contain lists of sensors or nose pokes for alternative DMTP tests for example where you need to perform a DMTP test in a five choice chamber Delays A list of delay entries In the DMTP task a variable delay is introduced between the Sample Lever response and the Choice stage The delay list determines the delay values that will be used Refer to
137. wing parameter types e FR Table FR Parameters VI FR Table VI FR Parameters The FR Table may be specified in Table mode or in Series mode In Table mode a single set of FR parameters are used to build the Fixed Ratio control in Series mode all entries in the FR Table are used to build the Fixed Ratio control If the database contains an FR Table in Series mode then multiple Fixed Ratio controls are generated one control per entry in the table in all other cases the auto control consists of a single Fixed Ratio control Edit Fixed Ratio Parameters Comment FR 10 Ratio Settings Control Options Ratio Enable Reset fio V Enable Rewards Disable Unused Lever Dummy As Target Target Dummy C None ce C Left Lever Press Right Lever Press C Central Lever FE Z e C Use Previous Use Selected Lever C Use Selected Sensor Cancel Figure 4 1 FR Parameters kK Limbic Developers Guide Auto Control Reference 62 A fixed ratio control contains the following settings Fixed Ratio The number of responses required FRn Target Assignment The lever or sensor to use as the Target Dummy Assignment The lever or sensor to use as the Dummy Enable Reset Reset the count if a response is made on the Dummy Enable Rewards _Enable Disable rewards Disable Unused Lever Ignore the unused lever Dummy As Target Treat the Dummy as if it were a Target Prior to the start of a
138. xit Stage Sets the exit state of the protocol state following completion of protocol Action Waits for a trigger to occur Reward Dispenses a reward reinforcement Mark Trial Set Outcome Increments the trial number amp defines the outcome of a trial e g correct incorrect etc Fixed Ratio Runs a fixed ratio Fixed Ratio Meted Variable Interval Shadow Stage Timer Stage Serial Choice Inter Trial Interval Serial Choice Present Stimulus Serial Choice Collection Serial Choice Timeout Serial Choice Training Interval Stage Delay Stage Progressive Ratio Stage Cued Choice Stage Sequential Choice Stage Cued Lever Stage Epoch Control Stage Outcome Stage DRL Stage Timeout Stage Location Stage Runs a fixed ratio Runs a variable interval Responds to the activation of a shadow trigger Used To Time the period of activation of a sensor The ITI stage of the 5CSRTT The stimulus amp limited hold of the 5CSRTT The Wait for collection stage of the 5CSRTT The Timeout stage of the 5CSRTT A training stage for the 5CSRTT A fixed or variable interval stage Waits for a specified delay to occur Implements a progressive ratio schedule Used in DNMTP protocols Defines a series of responses Defines a cued lever stage Controls the epoch manager Set the outcome of a trial Used in DRL tests A general timeout stage Defines the location of a subject kK Limbic Developers Guid
139. xperiment is described in K Limbic as a Protocol The protocol contains the information necessary to define an experiment from start to finish Subject Databases Subject databases are lists of subjects animals The operator assigns a subject to a box during the process of starting an experiment Each subject contains a unique set of parameters that have been predefined by the operator the values of the various parameters are used by K Limbic to customise a protocol for an individual animal For example during training for any complex task novice animals will commence a task using a set of parameters suitable for a novice as animals progress the task parameters increase in difficulty using a subject database provides a simple method of customising any task to the current training level of a subject Sessions A K Limbic experiment is run as a session The session file defines how many boxes will run which subject database will be used where the data is stored and how the data is analysed Test Suites A test suite is a wrapper for sessions and databases An individual test suite can contain up to 20 different session definitions and 20 different databases Therefore a single test suite file can contain everything you will need to define a complete study including training sessions test sessions and maintenance sessions K Limbic defines two forms of test suite Development Test Suites and Installed Test Suites these are discussed
140. y endpoint k Limbic Developers Guide Stage Type Reference 100 5 2 13 Serial Choice Collection Stage Components Driver Controls Display Message Target Dummy Settings Stage Exit Triggers Stage Reports Function A Serial Choice Collection stage is specifically designed to perform the Wait For Collection function in the five choice serial reaction time task The stage sets the state of the operant chamber normally just the house light then waits for a response in any sensor Normally there is no timeout associated with this stage the protocol pauses indefinitely until the subject makes some form of response The Serial Choice Collection stage automatically assigns all nosepoke sensors in the chamber as Dummy resources i e all the niche sensors A response in any niche during the Wait For Collection stage is normally considered a perseverative response i e a repeated response to the stimulus A five choice paradigm normally sends the protocol into a timeout state as a result of a perseverative response The developer normally assigns the sensor in the pellet receptacle as the target resource Activation of the target resource triggers the Exit On Target endpoint Activation of any dummy resource triggers the Exit On Dummy endpoint kK Limbic Developers Guide Stage Type Reference 101 5 2 14 Serial Choice Timeout Stage Components e Driver
141. y once per trial For an example of the use of Cued Choice stages refer to the K Limbic repository k Limbic Developers Guide Stage Type Reference 110 5 2 22 Epoch Control Stage Components e Epoch Controls e Display Message Function An Epoch Control stage is a protocol management stage The stage is used to mark the beginning of an Epoch within a protocol The duration of the Epoch is specified in the Epoch Control stage If an Epoch is running then any stage can use the Exit On Epoch stage endpoint as a means of ending the stage The protocol manager keeps a track of the active epoch when it times out if the current stage has an enabled Exit On Epoch endpoint trigger then the stage will exit A protocol can use as many epoch control stages as required although only one epoch can be active at any time If an epoch is active i e started but not yet timed out when a second epoch control stage starts a new epoch then the first epoch is abandoned and the epoch timer is reset to the values in the second epoch control stage An Epoch Control stage is instantaneous although there is a finite time taken to process an Epoch Control stage this time is very short and unperceivable by the subject k Limbic Developers Guide Stage Type Reference 111 5 2 23 Outcome stage Components e Trial Outcome e Display Message Function An Outcome stage is a protocol manage