USER MANUAL

image

Contents

1. 1 Utility LED 40 LINE 1 RJ45 Port 819101112613 5142 15 2 Faut LED e e eh me 2 DIP Switch 3 On Switch joe e CG E we 3 USB Communication Port 4 Off Switch O i 8 8 4 RS232 Communication Port 5 Battery Replacement LED 6 6 5 Internal CPU Reset Button 6 Battery Backup LED E Olle Olle press to shutdown 7 Screw for Easy Swappable Battery D 7H 4 6 Output Breaker Cover AAA 15 Ua 0 0 7 Outlet 8 Battery Low tow A eo Ore g Rating Label 9 Bypass n 9 Input Fuse 10 Utility Low UPS Boost gt F im 10 Input Power Cord Inlet N w gt a N w a a 11 Utility High UPS Buck 12 UPS Output Indicator LOAD GUE oa l COB a e 13 Polarity Error or Ground Fault T 8 8 14 Over load SO 6 6 m 15 Load Battery Level ibl 7 Oe K 2 o 16 Load Battery Level Indication Control Button G gt VG 40 Gy o e a 7 a Note Once the battery is disconnected the loads are not protected from power outages When the Battery Replacement LED Red lights up you may leave the UPS to be re charged for at least 8 10 hours to see whether the Red LED will be extinguished after the Self
2. 192321362000002 USER S MANUAL ORVALDI 1000VA 1500VA 2000VA 3000VA SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please follow all instructions carefully during installation Read this manual thoroughly before attempting to unpack install or operate CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants CAUTION Risk of electric shock do not remove the cover No user serviceable parts Refer servicing to qualified service personnel CAUTION Risk of electric shock hazardous live parts inside this UPS can be energized from the battery supply even when the input AC power is disconnected CAUTION Risk of electric shock Battery Circuit is not isolated from AC input hazardous voltage may exist between battery terminals and ground Test before touching O WARNING This is a Class A UPS Product In a domestic environment this product may cause radio interference in which case the user may be required to take additional measures NOTICE The UPS is designed to be for use with computer loads only NOTICE To prevent injury do not carry with the handle of front cover when moving the UPS 1 Inspection 3 Connect the loads 4 Connect Computer Inspect the UPS upon receipt Notify the carrier _ First connect the UPS with Utility then plug the and dealer if there is damage The package is load
3. ery 2 seconds in case of blackout or over under voltage Caution 1 The UPS On will not be executed if the above procedure is not done completely which means the button is released before all 4 LEDs LCD are extinguished 2 The UPS will remain at NO output if the start up operation is not proceeded properly even though the Input Power Cord is connected to the wall receptacle IMPORTANT NOTICE Plug the UPS into the wall receptacle to charge the UPS for over 8 hours after initial installation STORAGE Store at 15 to 30 C 5 to 86 F charge the UPS battery every six months Store at 30 to 45 C 86 to 113 F charge the UPS battery every three months Turn Off the UPS Push the Off Switch for at least 3 seconds to turn off the UPS If you press the Off Switch less than 3 seconds the UPS will not execute shutdown command due to insufficient pressing time In some occasions the UPS will shut itself down in case of overload output short circuited or battery cutoff point reached in the Backup mode The UPS will automatically shut off the output and beep for 5 seconds then completely shut itself down Plug in Charge If the Input Power Cord is connected to the wall receptacle properly and the utility is normal the UPS will start to charge automatically without processing Turn On procedure You have to charge for at least 8 hours eve
4. ry 3 months to avoid from battery self over discharge naturally if the UPS is in an idle condition Auto Restart The UPS will automatically restart to provide energy to the output if the utility recovers in 24 hours after battery cut The Backup LED will flash every 5 seconds under the waiting situation On the contrary the UPS will not auto restart if the Utility doesn t recover within 24 hours You are required to start up the UPS manually If you don t need UPS auto restart you can turn off the UPS by proceeding the Turn Off procedure Alarm Silence The Alarm might be turned off by pushing the On Switch for approximately 1 second in the Backup mode Unless any other warning or fault condition occurs the alarm remains at Silence condition once the Alarm Silence is turned off Test Under Utility Normal condition push the On Switch for 3 seconds to execute the Battery Self test function In case the battery is normal it will enter into Battery Backup Mode for 10 seconds then return back to Utility Mode If the battery voltage is detected lower than set limit the Battery Replacement LED will blink for 5 seconds then extinguish to stop self test procedure And if battery is detected weak or dead the Battery Replacement LED will steadily illuminate
5. s into the outlets on the rear of the UPS To Interface Port recyclable save it for reuse or dispose of it use the UPS as a master On Off switch make Connect the supplied interface cable RS 232 or properly sure that all of the loads are switch On USB Optional to the interface port on the rear of These UPS outlets provide battery power and eae iat cer Se adie do a surge protection to the equipment when utilit software installation guide in the UD 2 Place the UPS properly Jalaga outside aa e limits 7 Optional for installation purpose Caution Do not connect a laser printer to the LL We UPS outlets e 5 Connect Network a UPS Start Up H Connect the UPS to the wall receptacle Surge protection 3 Push the On Switch on the front panel of the UPS until 4 LEDs LCD are lit then extinguished Connect a 10 base T 100 base T network cable and release the On Switch into the RJ 45 network surge protection IN jack 3 The Backup mode LED Amber lights up and the UPS is under self test mode now If Utility is on the rear of the UPS Connect from the OUT normal the UPS will run under Utility mode Green LED after its self test is complete On the jack with network cabling to network equipment contrary the UPS will run under Backup mode and the buzzer alarms ev
6. test Function is executed again In case the Red LED remains unchanged you may unscrew the Easy Swappable Battery cover replace a new battery than push the On Switch to disable the RED LED Please follow the steps 1 7 to replace the new battery The voltage amp frequency of the UPS might be re set by the DIP z a Switch on the rear panel of the UPS The following charts may Indicator Color Description Alarm bring you clear pictures about how the settings are done by the Utility Mode Green Steady None DIP Switch Output Load is supplied by Utility FUNCTION ajai INO did A LINE Blinking Or RSE iTeY i i Cz Polarity error or Ground Fault VOLTAGE 120V iTi Backup Amber Steady with alarm Every 2 seconds DC START 50Hz i Mode Output Load is supplied by Battery before battery Low DC START 60Hz i Blinking every 5 seconds no and every 1 second E alarm Stand by for Utility before battery Cutoff recovery to re start up ene 3 z 1 NO did Fault Red When Overload short circuit or Buzzer beeps VOLTAGE 230V 14 Samra Output Voltage Abnormal occurs _ continuously VOLTAGE 240v_ A e DC START 50H 1 inkina i Wee ane i Battery Red Blinking Battery is weak and None Replacement needs to be recharged pral Steadv Ratterv ic dead