Home

User`s Manual Universal Mechanical Splice (No Tool) A. Instruction

image

Contents

1. Fiber Optics and Custom Solutions User s Manual Universal Mechanical Splice No Tool A Instruction for 900 900um or 900 250um Fibers The Tool function is built in No additional tool is required for the procedure Checker to see the result immediately MS Buttons Arm locked Locked i aga U lt Drawing gt MS Buttons and arms Lock Unlock Step 1 After striping fiber by stripper please cleave the fiber as the length of 12 5mm 0 5 inch Step 2 Insert 900um fiber to right side of Mechanical Splice and push the fiber to the end Step 3 Lock the right arm to fix Repeat step 1 for another fiber Insert 250 or 900um fiber to left side of Mechanical Splice and push the fiber to the end Page 1 of 2 Rev 2010C You may set Fiber Step 5 Form a curve on the left fiber step 6 Press both MS buttons completely during the left fiber is curving for connecting fibers step 7 Unlock the right arm Step 8 Now the job is done Fiber Optics and Custom Solutions User s Manual Rev 2010C Universal Mechanical Splice No Tool B Release Methods Use Our Release Key to push MS buttons up The Key is free to customers C Contact Information If you have any question for our products please contact us Page 2 of 2