1. Version M10 V2 01 11 08 Business Home GSM Alarm System 99 wireless zones i a ee a DO D ee Oo yS OO p _ _ _ _ _ N 2 GSM Intelligent Alarm System TO O O Installation and Users Guide V 2 01 Brief Introduction Industrial GSM 850 900 1800 1900 bands can be usedin most parts of the world choice Metal shell beautiful high grade Full duplex communication with the host Monitor the scene environment Wireless the doorbell function choice Phone SMS alarmat the same Voice and messagealert Set alarm ON or OFF byremote controller Can set Home Arm and Out Arm mode Call in toset alarm ON OFF Monitor Output Intercom Send SMS toset alarm ON OFF Monitor Output 5 group phone Can program ofalarm messages 5 zones for wired detector 99 zones for wireless detector 2 outputs can beset can be used with external circuitto control home appliance relay output linkage Easily set ON or OFF forevery wired or wireless detector SMS inform ifexternal power failure or recovery SMS Arm amp Disarm report Language Settings 6 bit password protection Wireless siren can be accessed Basic Kit contains Alarm system control unit 1pc Wireless PIR detector 1pc Wireless door gap sensor 1 pc Remote controller 2 pc Antenna Ipc Mini
2. all detectors work 1 2 Indoor arm part detectors work 1 0 Disarm all detectors not work O Language queries 3 1 Sounding immediately 3 0 Stop sounding 4 1 Open listen in use phone key 4 0 Closed listen in use phone key 11 1 Need siren sound when alarming 11 0 No siren sound when alarming 12 1 Sending SMS when alarming 12 0 No SMS when alarming 15 1 Dial phone number when alarming 15 0 Just alarm and no dialing 16 1 Disable Relay close 3 Min wien alarming 16 0 Set Relay close 3 Min when alarm 30 show the arm and disarm status of every zone 13 1 Arm amp Disarm report On 31 Change password Enter a new password 1 6 bid 13 0 Arm amp Disarm report Off 38 Set up alarm of zone wireles zone 1 99 wire zone 101 105 NOTE arm of single defense zone 39 Turn off alarm of zone wireless zore 1 99 wire zone 101 105 NOTE disarm of single defense zone 50 show preset phone number in the host 51 First group phone number 0 15bit 52 Second group phone number 0 15bit 53 Third group phone number 0 1 5bit 54 fourth group phone number 0 15bit 55 Fifth group phone number 0 1 5bit O 0 English 80 show preset SMS in the host 81 First group Message 0 24bit 82 Second group Message 0 24bit 83 Third group Message 0 24bit 84 Fourth group Message 0 24bit 85 Fifth group Message 0 24bit 8 6 Sixth group Message 0 24bit 8
3. group message into the host as second wireless detectoris triggered 123456 83 Back door open save third group message into thehost as third wireless detectoris triggered 123456 84 Front window open save fourth group message into thehost as fourth wireless detector is triggered 123456 85 Back window open save fifth group message into thehost as fifth wireless detectoris triggered 123456 86 Middle window open save sixth group message into the host as port 6to 99 wireless detector is triggered 123456 87 Kitchen opened save seventh group message into the hostas port 1 to5 wired detectoris triggered How to operate when the hostis alarming In normal usage if the hostis in disarmstatus the signal LED keeps onin green You can useremote controller tochange the hostinto arm status or you may sendSMSor call command 123456 1 1 to the host to change the host into arm status thesignal LED willflash in greenin arm status 1 Under arm status any portof input 11 12 I3 touches ground or letit open or wireless detectorsactivated or pressof alarm key of the controller the alarm system willsend alarm informationby SMS anddial out stored telep hone numbers Users cansendSMS command tothe host tochange these 7 kinds of alarm mess 2 The system will send presetalarm message before dialing alarm phonenum bers If the SMS has been closed or limited it will only dial out the alarm telephone numbers 3 Wh
4. lost you can cancelthe coded infor mation of this detector so thatit can notcontrol your alarmsystem Follow the below operationto reset the alarm system Keep pressing thereset button thenpower on thesystem LED flashes once it showsreset is successful All registered detectors have been deleted You can registerthem again withthe above mentioned process System reset will not change SMS message SOME NOTES 1 About STATUS light STATUS light keepson red in20 seconds afterthe host is powered on wireless detectors canbe coded intothe host thistime The light flash in red if codedsuccessfully 20 seconds later STATUS light flashin orange to show itstarts to searchfor GSM network If STATUS light still flashes 9 in orange itshows SIM cardis fixed incorrectly or GSM networkis poor If STATUS light stillon in green it shows noname or phonenumbers in SIM card If everything is ok STATUS light willflash slowly ingreen out arm mode or flash quickly ingreen home armmode or keepson in green disarm mode Ifalarm happened STATUS light willflash in redand start to dialout and sendSMS Standard components and optional available components The following sensors can be optional Additional wireless products a INS f g Y PIR Detectors Smoke Detectors Panic Buttons Wireless siren sound and light Password keyboard _ t oo J l ry B a E f n iiaa Door Window Remote Con
5. 6 51 13907550001 save first group alarm phonenumber into host 123456 52 13907550002 save second group alarm phonenumber into the host 123456 53 13907550003 save third group alarm phonenumber into host 123456 54 13907550004 save fourth group alarm phone number mtohost 123456 55 13907550005 save fifth group alarm phonenumber into host 2 There are7 kinds ofalarm messages inthe host The first five messages are for wireless detectors of zone 1 5 the sixth messageis for wireless detectors of zone 6 99 the seventh messageis for wired port I1 12 13 14 15 If the first wireless detector is triggered the alarm messageis Wireless Activated 01 If the second wireless detector is triggered the alarm messageis Wireless Activated 02 If the third wireless detector is triggered the alarm message is Wireless Activated 03 If the fourth wireless detector istriggered the alarm message is Wireless Activated 04 If the fifth wireless detector is triggered the alarm message is Wireless Activated 05 If the 6to 99 wireless detector is triggered the alarm messageis Wireless Activated 1 1 6 99 If the wired detector is triggered the alarm messageis Wired Activated 1 i 101 105 for port 1 to Salarm ages The alarm messagecannot be morethan 24 Englishcharacters 123456 81 Front door open save first group message into the host as first wireless detector is triggered 123456 82 Middle door open save second
6. 7 Seventh group Message 0 24bit O 1 Chinese 90 Show Output status in the host 91 1 Set 14 Output 1 change to high 91 0 Set U4 Output 1 change to low 92 1 Set 15 Output 2 change to high 92 0 Set 15 Output 2 change to low 93 1 Set talk to the host available EAKER open 93 0 Set talk to the host unavailableSPEAKER closed 94 1 Set Relay to be connected 94 0 Set Relay to be disconnected 95 1 Set alarm when line input 1 opan 95 0 Set alarm when line input 1 connect to Gnd 96 1 Set alarm when line input 2 opan 96 0 Set alarm when line input 2connect to Gnd 97 1 Set alarm when line input 3 opm 97 0 Set alarm when line input 3connect to Gnd 98 1 Set line input 4 open 98 0 Set 4 connect to Gnd 99 1 Set line input 5 open 99 0 Set 5 connect to Gnd 61 1 Set port I4 as input 61 0 Set port I4 as Output 69414 Set port IS as input 62 1 Set port I5 as Output 1 Above table stands for defaultsetting 2 In theabove phone operation one beep showsthe number your input is suc cessful a longbeep shows the sentence you inputis successful two short beeps show sentence you input is failed you shouldtry again 3 In the above SMS operation you will receivea reply message for confirma tion after sending message command tothe host Suchas 123456 Host Arm SMS On Phone On Siren On Arm amp Disarmreport Off Alarm linked Relay On If the replied messa
7. en thereis alarm youcan answer the phone no needto input password for listen in remote control Press 3 1 to sound thesiren and press 3 0 to stop it press4 1 to startto listen in and press 4 0 to stop it press 93 1 to start totalk to thehost and press 93 0 to stopit 4 After pickingup alarming calls if you donot need thehost dial next phone number programmed in the host just press 1 l or 1 2 tore turn the host to arm status 5 When thereis alarm userscan also usethe controller todisarm the hostif they are nearby 6 In normalusage with insiderecharge battery on you willreceive the mess age external power failure or external power recovery when external power supply lostor recovered How to SMS or Call control the host instructions table 1 Sending messageto the host phone number SIM Card number Send the messageto the host enter password 123456 add the following command to setthe host 2 Calling the host phone number SIM Card number Call in thehost and enter password 123456 theninput the followingcom mand to setthe host For example Inquires the host system status instructions 123456 System Reply Host Arm gt SMS On Phone On Siren On Arm amp Disarm report Off Alarm linked Relay On d Com Function Com Function 1 1 Outdoor arm
8. er 4 Connect thesiren to alarm system Connect the black wire to GND port and red wire to siren port S AC 220V Speaker Siren n o AAABAA AA DC12V ON OFF ovo tf In5 In4 In3 In2 Ini ANT RELAY Speaker Wired4 Wired Wireless ANT Power Power sw Wired5 Wired3 Wired 1 Monitor Relay 5 Connect wired sensors Five inputs areavailable to connectwired sensors Inputs are independent and are notcoded as different zones Sensors must be NC normally closed type More than sensor can beapplied at one input connecting theiralarm conta cts serial The inputs canbe connected withany number ofwired sensors aslong as total resistance isunder 220 ohms When these sensors are triggered the alarming message will be Wired Activated 101 105 6 Connecting switched output devices Home appliance Control open outputs andone internal relay controlled by telephone are available Internal onboard relay is activated whenan alarm occursand can be deacti vated reactivatedthrough telephone commands or SMS textmessage It can beused for example to command an external light Open outputs canbe used directlyif your equipmentcan operate arelay Do connect an antiparallel diode withrelay coil These outputs canbe operated only by telephoneor SMS textmessage commands Wiring Explanation For home appliance control for special order The controller boxhas four wires 1 Two yellow AC 220 w
9. ge is aboutthe current status of the host you may have sent wrong command 4 You can also send inquiry commandto check outthe present status of the host 5 When the external power is cut off the system willsend SMS Power chan ger off to inform When the external power resumed the system will send SMS Power changer on to inform How to use remote controllers Disarm D Out arm D O Stay arm SS Alarm There are four buttons on the remote controller Out Arm key Pressthis button the signal LED flashslowly in orange for 30 seconds system isin arm wait status 30 seconds later the signal LED flash slowly in green system is inout arm statusnow Youcan set outarm mode when no oneis at home all the detectors at home willbe in working mode Home Arm key Pressthis button the signal LED flashslowly in orange for 30 seconds systemis in arm wait status 30 seconds later the signal LED will flash quicklyin green systemis in homearm status now You can setho me arm mode when there issome one athome sensors ininner defense zone will be invalid but sensors inother defense zones still work normally Disarm key Pressthis button allthe detectors are disarmed the lighton panel will keepon in green Arm Alarm Quick Arm Alarm key Pressthis button the light on panel will flash inred the system will be alarming and the host will send the SMS and dial out 8 How toadd more detect
10. ires to beconnected with Homeappliance 2 GND 12V DC wires tobe connected witha 12V DC Power supply Configuration of the host There are 11 connector ports on top ofthe host GND SIREN RELAY RELAY SPEAKER In5 1In4 In3 In2 Inl ANT 3 I1 12 13 These 3 ports for input every port canbe connected with ground or open tomake alarm out 14 15 These 2 ports for output youcan call inor send SMS to set it If output of these ports goes high the light of OUT 1 or OUT 2 will lighton the panel NOTE these ports must be connectedwith external circuit un professionals should use with caution SPEAKER This port is forvoice output itcan be connectedto the spe aker The other portof the speakeris connected to ground You can control it by callin or sendthe If this function avails 93 1 or 93 0 RELAY RELAY Thesetwo ports willbe closed for3 minutes when ahrm happens You can usethese two portsto start the power supply ofthe camera when alarm happens This function can be disabledby set command 16 1 You can alsomake this relayclose or openanytime by sending SMS or phone calls 94414 or 94 0 SIREN This port outputs sirentone alarm itis to beconnected with the sien The other port of sirento be connectedto ground GND power ground How to setupthe alarm phonenumbers and SMS 1 You can sendSMSorcall command tothe host tosetup 5 groupsof alarm phone numbers The formatis Password operation code content 12345
11. ors Youcan add more sensors and detectors such as wireless door sensors PIR sensors gas andsmoke detectors into the host 1 Addsensors ready to work when youset both Out Armand HomeArm When the GSM host beginsto be poweredon the status LED light onpanel will be redfor 20 seconds this is codelearning mode Youcan trigger the sensors or detectors and the red LED will flashto show itis coded success fully into the host The coding mode ends 20seconds later automatically and systementers in to working mode status LED lighton panel willchange to yellow then to green 2 Addsensors into inner defense zone Detectorsin this zoneare ready to work when youset Out Arm and willnot work whenyou set Home Arm When the GSM host beginsto be poweredon the status LED light onpanel will be red Push the reset button for onesecond the status LED light will light up inorange for 20seconds Thisis code learning mode of inner defen se zone Youcan trigger thesensors or detectors the LED willflash in red to show itis coded successfullyinto inner defense zone For above operation the host willexit code learning mode 20 seconds later automatically and enters into working mode thelight on panelchanges to orange to searchfor GSM network then to green Note If there were4 wireless sensorsin the host stand for zone 1 to zone4 then the newadded sensor willbe 5th zonein the host 2 How to cancel the lost detectors In case someof the coded detectors are
12. requency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal110 Vertical 60 Working Condition Temperature 10 C 40 C Humidity 90rh Remote Control Power Supply DC12V inner DC12V battery Transmission Current 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m
13. trols LPG Gas Detectors Electronic fence Doorbell button gap sensors ee Speaker Optional sensors detectors are packed separately It includesremote contin uerollers wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button baluster etc Youmay purchase according your specific requirements Typical house contiguration ig External Sirens TE Remote contral p aN 5 4 wy IE A OA F 7 i Ni oe iF dlri tS ce 4 im il _ pi o Lgl a e Electronic fence Garage Dooriwindow Detector aE Detectors Doorbell button SOME TECHNIQUE PARAMETER 1 Static current 40mA 2 Power 9V 12VDC 3 Working temperature 20 C 55 C 4 GSM850 900 1800 1900MHz band 5 Receiving code ASK 6 Frequence 315 433MHZ 7 wireless distance 100M 8 wireless detectors 99 9 wire detectors 5 Outer Alarm Siren Volume 110dB Working Condition Temperature 10 C 40 C Humidity 90 rh Wireless Gap Detector Door Window Contact Power Supply DC12V inner 12V battery Static Current 20 u A Transmission Current 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Internal Distance 15mm Working Condition Temperature 10 C 40 C Humidity 90 rh Wireless PIR Detector Power Supply DC9V inner 9V battery Static Current 100 mA Transmission Current 20mA Transmission F
14. wiredsiren 110dB 0 3m 1 pc Power supply with back up 1pc Installation user manual Ipc Installation guide 1 Insert SIMin alarm unit Press the yellow point on top of the mainunit with apencil tip or other tools SIM tray willcome out Putthe SIM cardcarefully into the tray andmake sure the metal contacts of the SIM to bedown Note Before inserting SIMcard into alarmunit using aregular mobile phone to dothe following steps Set PIN code request to off Delete allstored numbers 2 Connect the antenna Screw the antennato the connectionon top ofthe main unit Takecare not to over tight the nut or letit loose 3 Insert the powersupply Connect the host with the adaptor The hostneed 9V 12V DC mustbe over 1000mA current The signal status LED on the main unit panel will turn tored and last for 20 seconds this iscode learning mode system is waiting for wireless detectors to be coded into the host After 20 seconds the signal status LED will turnto orange and begin toflashi indicating system ischecking SIM cardand search forGSM network After main unit finish checking the host if the signal status LED turns to gre en and flashes slowly it shows alarm phone number havebeen saved inthe host and the host is inarm status Ifthe signal status LED keeps onin green it shows phonenumbers have notbeen saved inthe host andthe host isin disarm status Youcan dial inthe host orsend SMS toprogram the phone numb

Download Pdf Manuals

image

Related Search

Related Contents

TestBed User Manual [PDF/1177KB]  - Sika Colombia  Four-channel Pulse Counting Detector Controller User Manual  30-08-2013 (Lisboa)  Notes - Dukane  A-A1S Module Conversion Adapter User`s Manual  Pride Mobility GC Controller INFMANU3355 Owner`s manual  仕様書 - 奈良先端科学技術大学院大学  INFORMACIN TCNICA  Manual do Proprietário  