Home
DIN-20-BAS
Contents
1. 200mA max 400Vdc max 250Vac max Input connections din20 TAC din20 VAC din20 BAS LS ASt ASZ pud AH 4 20mA 4 20mA Modbus RTU O Out 2 0 2A 250Vac max e o Out 1 0 2A 250Vac max sindino 9194 HYSS Common RN VERDE _ 4 20mMA Gnd Gnd TC y BEU AZUL 0 10V 0 60mV 4 20mA PT 100 BRN CAFE I fig din20 1 CAUTION Set internal jumpers Gnd Mechanical switch 75y REULAZUL RN CAFE BLK NEGRO Low voltage Inductive proximity input pulse switch NPN PNP High voltage input pulse 6omv 2v Caution Set internal jumper 6V 20V 60V 200V 600V RN VERDE 4 20mA rc Gnd Gnd TC BEU AZUL 4 O 10V 0 60mV 4 20mA PT 100 BRN CAFE fig din20 2 BRO DIN20 E 03 2009 http Avww arian cl Aa Muli Sy eo S Ni a S 4 F 2 N S Sy eo S Si Input configuration jumpers 1 1 oJ 000000 Xe Bi L aaa ooo 000 oo000 00000 3 Z S 4 F N S Sy eo S
2. Si 0 din20 BAS Bo AOL ALU ial din20 TAC NPN PNP E E z T H Mechanical Switch EG H O O din20 VAC 5 Amp 60mV OO HoA OO Oa OOOO0O CHAA OOOO OOOH 20V 60V OO OO Ha mogo 00m AO OOE 4 20mA 0 20mA 0 10V 0 5V 1 5V OO OOH 2V QO Od Thermocouples Pt 100 0 50mV TTL Low Voltage 0o oO 0 0 E eV oo oo DOO DOO 600V Og Od OOOO OOO din20 03 BRO DIN20 E 03 2009 http Awww arian cl 4 20mA and 0 10V active output configuration jumper 0m 4 20mA N A Geo 0 10V SEA SISI CL SI Sana din20 04 PART CODES din20 BAS thermocouples pt100 0 10V 4 20ma TAC rate meter VAC amperimeter voltimeter DC and AC true RMS Optional 420L 4 20mA pasive loop analog output 420A 4 20mA active includes 0 10Vdc analog output RS485 modbus RTU serial communications Example din20 BAS 420A RS485 MORE INFORMATION ARIAN S A El Comendador 2340 Providencia Santiago Chile Fono Fax 56 2 4218333 arian arian cl www arian cl C Copyright ARIAN S A 2009 BRO DIN20 E 03 2009 http Awww arian cl
3. A FR LAN Industrial Control amp Instrumentation Din rail isolator amp transmitter din20 e din20 bas Thermocouples Pt100 4 20ma 0 10V process inputs e din20 vac True RMS AC DC Volt Amper input e din20 tac Tachometer 0 01 Hz 50KHz pulse input e 4alarms associated to 2 output solid state relays e Isolated 4 20ma and 0 10V outputs e RS485 modbus RTU serial communications General description Isolation Inputs Alarms Analog output Programming The din20 din rail isolators are based on Arian id20 digital panel indicators having the same funtionalities except for not having a display and enhaced isolation characteris tics Composed by 3 sub models din20 bas din20 vac din20 tac they cover a broad range of input types Complete galvanical isolation between power supply input analog output solid state relays and RS485 communications The din20 bas includes thermocouples Pt100 4 20mA 0 10V and 0 50mV process inputs The din20 vac is a AC true RMS volt and amper input instrument also bipolar DC with several scales May be used with shunts current transformers or direct measure ment of AC DC voltages up to 600V The din20 tac is a tachometer or rate meter only accepts pulse inputs e g NPN PNP and Mechanical Switch Frecuency measurement is done counting the input pulses and simultaneously measuring the time among them This method allows precise and quick readings especially
4. at low frequencies where the measurement is obtained mainly from the period time among pulses Simplifies input programming not having to define time windows on which the count is carried out Possess two output solid state relays each one corresponds to 2 programmable alarms high and low Alarms can be absolute or relative to a general set point Isolated analog outputs 0 10Volt 4 20mA active or loop powered Set up and configuration is done by the Arian RPS software running on a PC Com puter connection is made to the RS485 port using the IS0485 interface or to the internal connector with the RPS interface Since funtionalities are exactly equivalent with the id20 panel meters detailed configu ration is found on the id20 user manual BRO DIN20 E 03 2009 http Awww arian cl 1 TECHNICAL SPECIFICATIONS INPUTS din20 bas din20 vac din20 tac Resolution 16 bit a d CMRR 100 dB min 400 VAC Min Input break protection TC with preset action Thermocouples 100 ohm max Centigrade Degrees or Fahrenheit 60 760 C 100 1372 C 86 400 C 1 mV 1767 1 mV 1764 1 mV 1815 139 1298 C 176 750 C 0 1394 C 0 2314 0 2314 0 2313 C PT100 136 450 CC DIN43760 alpha 0 0385 4 20 mA 0 20 mA 0 5 V 1 5 V 0 10 V 0 50 mV scalable for engineering units atinel QvowvMmMmZz200n0DFxc Resolution 18 bi
5. remote programming software provided on http Awww arian cl downloads arianrps zip and running on windows PC Connection can be done from the RS485 lines using the IS0485 interface to the PC RS232 comm port Also may be done using the RPS interface cable plugged to the internal connector taking care of the UP direction for the connector as seen on the figure Remove the four top cover screws for accessing the RPS connector and other internal jumpers needed for setting the input and output type UP RPS Connector C I TEER Pla LA The RPS software will recognize the device and load the proper driver for reading and writing configuration parameters Since the din20 is functionally equivalent to the ind20 panel meters you may refer to the id20 user manual for further references ee H Dem Sask i ET E lasam rams m n Gia amaa A T Se Coste WA me me e caman T at T Dmi amn T hn BRO DIN20 E 03 2009 http Awww arian cl Analog output and solid state relay outputs 420L option 4 20mA loop powered pasive output 420A option 0 10V and 4 20mA active outputs R load 700 ohms max 4 5V min 30V max 200mA max
6. t a d CMRR 100 dB min 400 VAC Min De Bipolar simetrical input positive negative voltages currents Ac True RMS Scales 5 Ampers 60mV 2V 6V 20V 60V 200V 600V Pulse inputs NPN PNP Mechanical switch TTL High voltage 500 V Provides feeding for input sensor 5 7 5 Vdc 30mA max Frequency range 0 01Hz 50KHz ALARM RELAYS Two solid state bipolar for DC or AC use relays outputs for alarms 400 VDC max and 200mA max This must be used with external larger power relays unless are conected to low power loads such as PLC or DCS inputs Normally open or normally close software configured Independent alarm outputs each one with high and or low alarm with absolute or relative set point RS485 Modbus RTU protocol serial communications half duplex RS485 not RS422 Opto isolated up to 5kV ANALOG OUT Loop powered Active loop 4 20 mA loop powered Voltage drop 4 5V max Operating voltage 30V max Opto isolated 5kV 0 10V and 4 20mA Active loop driving up to 14 volts onto loads 700 ohms max load Opto isolated 5kV POWER SUPPLY Low noise switching power supply 5kV min isolation from analog input 20Vdc 28Vdc 3 W max CONSTRUCTION Reinforced polyester Total Dimension Weight Operation temperature 121 x 98 x 23 mm 200 grams 0 50 BRO DIN20 E 03 2009 http Awww arian cl 2 PROGRAMMING Set up configuration is done with the RPS
Download Pdf Manuals
Related Search
DIN 20 BAS din baskets din base din basic 2 din based search din basketball din basmele popoarelor asiei din basket side perforated din basic
Related Contents
Sendmail <HNAS_SNMP監視 取扱説明書 別紙2 イベントリスト> Event ID 概要 3. How To - PCE Instruments 1 - Mademsa Návod na obsluhu GECOL Caucho Negri Electronics 500T User's Manual Copyright © All rights reserved.
Failed to retrieve file