Home
        Manual - Gefen
         Contents
1.     get_outdev_name  Device output name   None     help  The  help command displays the list of available RS 232   IP commands  The  help    command can also be used to provide help on a specific command     Syntax      help  paraml     Parameters     param1 Command  optional     Notes     When asking for help on a specific command  the         character must be included as part of  the command     Example    help  fadefault  Cmd  fadefault  Return to factory default  Routing 1  Disable Lock    power mode  IR RMT add 0    page   19    Advanced Operation    RS 232   IP Commands     ipconfig    The  ipconfig command displays the current TCP IP settings     Syntax      ipconfig    Parameters     None    Example      ipconfig    MAC addr 00 1C 91 02 50 27   IP addr 192 168 2 204   Net Mask 255  255 255 0   Gateway   192 168 2 1   Web Server Port   80   Telnet Server Port   23   Telnet password on login is set to OFF    Telnet welcome at login is set to OFF    page   20    Advanced Operation    RS 232   IP Commands     irrmtadd   The  irrmtadd command sets the IR channel of the switcher  In order for the included  IR remote control unit to function correctly with the switcher  both the IR remote control  unit and the switcher must share the same IR channel  After executing this command  the    DIP switch settings for the included IR remote control unit are returned  See Setting the IR  Channel for information on setting the IR channel on the IR remote control unit     Syntax      
2.    34    Appendix    Mounting Plate Installation    Rack mount ears are provided for installation of this unit into a 1U rack mount space     poni    Locate the side screws on the unit    Remove the front 2 screws that are located closest to the front of the unit   Using the removed screws  screw the rack mounting bracket into the unit   Repeat the procedure on the opposite side of the unit     Front of unit  Rear of unit       page   35    Appendix    Specifications  Resolution  max       2560 x 1600         360 MHz  4 x LED  blue  1 x LED  red    Maximum Pixel Clock        Input indicators       Power Indicator    Video Inputs   4 x DisplayPort  female  Video Output   1 x DisplayPort  female  Audio Inputs    4 x 3 5mm mini stereo  Audio Output   1 x 3 5 mini stereo  USB   4 x Type B  female     1 x Type A  female  RS 232    1 x DB 9  male  Ethernet   1 x RJ 45  100BaseT   IR Extender   1 x 3 5mm mini stereo jack  Input buttons     4 x Push button  momentary    Power Input 1x5V DC    Power Consumption  max                   17 1    x 1 75  x 4 25    434mm x 44m x 108mm     Dimensions  W x H x D           Unit Weight 1 8 lbs  0 8 kg     page   36             Stretch it  Switch it  Split it  Control it   Gefen s got it   amp     20600 Nordhoff St   Chatsworth CA 91311  1 800 545 6900 818 772 9100 fax  818 772 9120  www gefen com support gefen com       amp  E cc  amp        This product uses UL or CE listed power supplies     
3.    User Manual  Release A5       Gefen    4x1 DPKVM Switcher    Important Safety Instructions    Ni pr Ov ge iD cx    10     11   12     13   14     15     GENERAL SAFETY INFORMATION    Read these instructions    Keep these instructions    Heed all warnings    Follow all instructions    Do not use this product near water   Clean only with a dry cloth     Do not block any ventilation openings  Install in accordance with the manufacturer s  instructions     Do not install or place this product near any heat sources such as radiators  heat  registers  stoves  or other apparatus  including amplifiers  that produce heat     Do not defeat the safety purpose of the polarized or grounding type plug  A polarized  plug has two blades with one wider than the other  A grounding type plug has two  blades and a third grounding prong  The wide blade or the third prong are provided for  your safety  If the provided plug does not fit into your outlet  consult an electrician for  replacement of the obsolete outlet     Protect the power cord from being walked on or pinched particularly at plugs   convenience receptacles  and the point where they exit from the apparatus     Only use attachments accessories specified by the manufacturer     To reduce the risk of electric shock and or damage to this product  never handle or  touch this unit or power cord if your hands are wet or damp  Do not expose this  product to rain or moisture     Unplug this apparatus during lightning storms or when unused f
4.   ON  gt   0 0 JO u   OUN  gt           Only TXD  RXD  and GND are used     RS 232 Settings    Description Setting  Baud rate 19200  Data bits 8  Parity None  Stop bits 1  Hardware flow control None    IMPORTANT  When sending RS 232 commands  a carriage return  must be included at the end of the command  A space must be    included between the command and each parameter        page   14    Advanced Operation    RS 232 and IP Configuration  IP Configuration    The 4x1 DPKVM Switcher supports also IP based control using Telnet  To set up IP  control  the network settings for the 4x1 DPKVM Switcher must be configured via RS 232   The default network settings for the switcher are as follows     Description IP Address   Port Description IP Address   Port  IP Address 192 168 1 72 Telnet Port 23   Subnet 255 255 255 0   Gateway 192 168 1 254   HTTP Port 80    1  Connect an RS 232 cable from the PC to the 4x1 DPKVM Switcher  Also make sure  that an Ethernet cable is connected between the switcher and the network     2  Launch a terminal emulation program  e g  HyperTerminal  and use the RS 232  settings listed on the previous page     e NOTE  Depending upon the network  all related IP   Telnet settings    will need to be assigned  Consult your network administrator to  obtain the proper settings        3  Set the IP address for the switcher using the  sipadd command    4  Setthe subnet mask using the  snetmask command    5  Set the gateway  router  IP address using the  sgateway comm
5.   keyboard  camera  etc   to the USB Out  ports     5  Connect the included 5V locking power supply to the power receptacle on the 4x1  DPKVM Switcher  Connect the AC power cord to an available electrical outlet     6  To use the RS 232 communication feature  connect an RS 232 cable between the  Switcher and RS 232 host controller     7  To communicate with the Switcher using Telnet  connect an Ethernet cable from the  Ethernet jack on the back of the Switcher to the network  See IP Configuration for  more information on using the Telnet feature     8  To extend the range of the IR control  connect an IR Extender  Gefen part no   EXT RMT EXTIR  to the back of the Switcher     Sample Wiring Diagram    MINI STEREO AUDIO CABLE     gceren Ber Canis    RS 232 CABLE  USB CABLE  ETHERNET   IR    Computer    Computer  gt       IR Extender    RS 232 Controller    Powered Speakers    EXT DPKVM 441    WARNING  This product should always be connected to a grounded  electrical AC outlet        page   7       02 Operating the  4x1 DPKVM Switcher    SwitchirigiSoU Ges ree eR END UTIQUE UE TENURE 10  Switching sources using the Front Panel Buttons                          10  Switching sources using the IR Remote Control                            11    Switching Sources    Switching sources using the Front Panel Buttons    The front panel of the 4x1 DPKVM Switcher has a set of four  4  LED indicators  displaying  which input  source  is being displayed  Each of these LED indicators correspo
6.  Parameters     param1 Gateway    Example      sgateway 192 168 1 1  New IP Gateway set to  192 168 1 1     show_pass  The  show pass command displays the current Telnet password  Use the  set_ pass    command to set the Telnet password     Syntax      show_pass    Parameters     None    Example      show_pass  Telnet password  reindeer    page   25    Advanced Operation    RS 232   IP Commands     show_user_name  The  show_user_name command displays current user name  Use the     set_user_name command to set the user name     Syntax      show_user_name    Parameters     None    Example      show_user_name  Telnet login  Admin     show_ver_data    The  show ver data command displays the current hardware and firmware version     Syntax      show ver data    Parameters     None    Example      show ver data    Hardware version 0   Firmware Release version 1 4 9  Release date  Apr 22 2012  Release time  14 56 52   Boot loader version 1 6    page   26    Advanced Operation    RS 232   IP Commands     sipadd  The  sipadd command sets the IP address of the switcher  The IP address must be    entered using dot decimal notation  The switcher must be rebooted after executing this  command     Syntax      sipadd paraml    Parameters     param1 IP address    Example      sipadd 192 168 1 127  New IP set to  192 168 1 127     snetmask  The  snetmask command sets the subnet mask  The net mask must be entered using    dot decimal notation  The switcher must be rebooted after executing this
7.  Switching SOU COS iii e e il ira ila 10  Switching sources using the Front Panel Buttons       10  Switching sources using the IR Remote Control    eee eee 11   Advanced Operation   RS 232 and  IP Configura aa 14  RS 232 Interface    iaia 14   S aT 14   P Gonfigurationi    cci cec een 15   RS 232 SS neta sonent Repo hire 16   Appendix   Firmware  Upgrade Procedure cocinar 34   Mounting Plate Installation u    petere is 35   Specifications  sans e EE E ii nia 36    viii    01       Getting Started     to e wel Oo OST           Fra E NR EE  BackiPanel ee CR ee  IR RemoteiGontrollUnite e nni    Backen eter cea  Installingithe Battery eere eere ere UII TEMERE  settingitheilR Channelt see Eee  Installationizs o see ree rere ee Pereira VE A RAE ster ee dedere a  Connecting Ne ADAMS Eee  SAMPIEWINNGIDIAGANEZE noe         Getting Started    Panel Layout           Input indicators Each of these LED indicators glows bright  blue according to the input selection          Receives IR signals from the included IR  remote control unit             Press these buttons to select the desired  input     Input buttons       This LED indicator will glow bright red when  the unit is powered          page   2        Getting Started    Panel Layout    Back Panel          1 5V DC Connect the included 5V DC locking power  supply to this receptacle     2 Audio In  1   4  Connects up to 4 audio sources using 3 5mm  mini stereo cable     3 DP In  1   4  Connects up to 4 DisplayPort sources     4 Audio O
8.  command   The default net mask is 255 255 255 0    Syntax      snetmask paraml    Parameters     param1 Gateway    Example      snetmask 255 255 0 0  New IP mask set to  255 255 0 0    page   27    Advanced Operation    RS 232   IP Commands     stbymode    The  stbymode command toggles the Standby Mode state  When Standby Mode is  enabled  the LED of the currently active input will flash  Once the switcher is placed in  Standby Mode  no video will be displayed  The power LED will continue to glow bright red   Placing the switcher in Standby Mode does not power down the switcher     Syntax      stbymode param      Parameters   param1 Value  O     1   Value Description  0 Disable Standby mode  On   1 Enable Standby mode  Off   Examples      stbymode 1  Video power is set to OFF     stbymode 0  Video power is set to ON    page   28    Advanced Operation    RS 232   IP Commands     use_telnet_pass    The  use_telnet_pass command enables or disables the login credentials when  starting a Telnet session     Syntax     fuse telnet pass paraml    Parameters    param1 Value  O     1   Value Description  0 Disable password  1 Force password   Example     fuse telnet pass 1  Telnet password on login is set to ON    page   29    Advanced Operation    RS 232   IP Commands    r    The r command switches to the specified input  Do not precede this command with the          symbol     Syntax     r paraml    Parameters     param1 Input  1     4     Example     3  Route to input 3    page   3
9. 0       04 Appendix    ElrmwareUpgrade rc ee 34  Mounting Plate Installation en  SA E       Appendix    Firmware Upgrade Procedure    The following items are required to update firmware     Gefen 4x1 DPKVM Switcher   Computer running Windows XP  Terminal emulation program  e g  HyperTerminal   RS 232 cable  do not use a null modem cable     Firmware files  downloaded from Gefen Web site     To begin the update procedure use the  activebolo command  The following set of  instructions will be using Hyperterminal     1   2     son       Power on the switcher     Connect an RS 232 cable to the PC and open the terminal program   See RS 232 Settings for configuration information     Type the command  activebolo and press the ENTER key     Type and enter the  activebolo command a second time     The following will be displayed on the terminal screen     Download new program 1  Cancel 0       Press the    1    on the computer keyboard to select Download new program   The following will be displayed    Waiting for the file to be sent      press  a  to abort   In Hyperterminal  click Transfer      Send File      Select the firmware file using the Browse button     Select YModem from the Protocol drop down list    Click the Send button on the Send File dialog    The firmware update procedure will begin  This process should take a few moments   After the firmware update is successful  the following will be displayed in the terminal  program     Programming Completed Successfully     page
10. TWARE  EVEN IF  ADVISED OF THE POSSIBILITY OF SUCH DAMAGE     vi    Features and Packing List    Features      Front panel switching using discrete select buttons     Supports resolutions up to 2560 x 1600     Supports RGB and YCbCr color spaces     RS 232 control     IP control     IR remote control     Supports USB 2 0 with backward compatibility for USB 1 1    Jack for external IR Receiver  EXT RMT EXTIR      Save space on your desktop      Rack mountable    Packing List    The 4x1 DPKVM Switcher ships with the items listed below  If any of these items are not  present in your box when you first open it  immediately contact your dealer or Gefen       4x1 DPKVM Switcher     1x6 ft  DisplayPort cables     1x6 ft  USB 2 0 cables  A   B      1x6 ft  3 5 mm mini stereo audio cables     1 x IR remote control unit  EXT RMT 4IR       1 x 5V   4A DC locking power supply  EXT PS54AULP     1 x Set rack ears     1 x Quick Start Guide    vii    4x1 DPKVM Switcher    Table of Contents    01    02    03    04        Getting Started   Panel LQVOUE mec                                                    2  grenier eem                2  Back Panel cacon eating 3   IR  Remote  Control Unit coopera ans 4  rojo PNE E A ea diante 4  sr TTT 5  Installingithe Battery    a cec M repe ca Hen o teet ee ante 6  Setting the IR Channel    aka 6   installation  7  Connecting the 4x1 DPKVM Switcher                    iii 7  Sample  Wiring Diagrami      sissi ire 7    Operating the 4x1 DPKVM Switcher      
11. and   6  Set the Telnet listening port using the  set telnet port command   7  Set he HTTP listening port using the  set http port command     8  Reboot the switcher to apply all changes  then type the IP address that was  specified in step 3  in the Telnet client to access the switcher     page   15    RS 232   IP Commands          r    activebolo    display telnet welcome    fadefault   get indev name  get outdev name  help   ipconfig  irrmtadd  resetip   set http port  set indev name  set outdev name  set pass   set telnet port  Set user name  sgateway   show pass   show user name  Show ver data  sipadd   snetmask  stbymode    use telnet pass            Activates the boot loader  Enables   disables the Telnet welcome message       Resets the routing state to factory default settings  Retrieves the specified input device name  Retrieves the output device name   Displays the list of RS 232   Telnet commands  Displays all TCP IP settings   Sets the IR channel for the switcher       Sets IP configuration to default settings   Sets the Web server listening port   Sets the name of the specified input device   Set the name of the output device   Sets the Telnet password   Sets the Telnet listening port   Sets the Telnet user name   Specifies the new gateway   Displays the current Telnet password   Displays the current Telnet user name   Displays the current hardware and firmware version  Specifies a new IP address   Specifies a new net mask   Enables   disables Standby Mode   Tog
12. gles Telnet password prompt        Switches to the specified input    page   16    Advanced Operation    RS 232   IP Commands     activebolo  The  activebolo command activates the boot loader  This command is use when    upgrading the firmware  See the Firmware Upgrade Procedure for instructions on  upgrading the firmware     Syntax      activebolo    Parameters     None     display telnet welcome  The  display telnet welcome command enables or disables the Telnet welcome    message     Syntax      display telnet welcome paraml    Parameters    param1 Value  O     1   Value Description  0 Disable welcome message  1 Enable welcome message    page   17    Advanced Operation    RS 232   IP Commands     fadefault  The  fadefault command resets the routing to factory default settings     This command is similar to the  resetip command  except that TCP IP settings are  preserved     Syntax      fadefault    Parameters     None    Example      fadefault  Return to factory default  Route to input 1     get_indev name  The taer indev name command retrieves the specified input name  Use the     set_indev name command to assign a name to the input     Syntax      get_indev name    Parameters     param1 Input  1     4     Example      get_indev_name 1  Device input name   Macbook    page   18    Advanced Operation    RS 232   IP Commands     get_outdev_name    The  get_outdev_name command retrieves the output device name     Syntax      get_outdev_name    Parameters     None    Example  
13. irrmtadd paraml    Parameters     param1 IR channel  O     3     Example      irrmtadd 2  Set IR RMT 2     resetip  The  resetip command resets the IP configuration to factory default settings     The switcher must be rebooted after executing this command     Syntax      resetip    Parameters     None    Example      resetip  TCP IP configuration was cleared to default  reboot to take efect    page   21    Advanced Operation    RS 232   IP Commands     set_http_port  The  set_http_port command specifies the Web server listening port  The switcher    must be rebooted after executing this command  The default port setting is 80     Syntax      set_http_port paraml    Parameters     param1 Port  1     65535     Example      set_http_port 82  New HTTP port set to  82     set_indev_name  The  set_indev_name command sets the name for the specified input  The name of the    input cannot exceed 15 characters in length  Use the  get_indev_name command to  retrieve the specified input name     Syntax      set_indev_name paraml param2    Parameters    param1 Input  1     4   param2 Name   Example      set_indev_name Macbook    page   22    Advanced Operation    RS 232   IP Commands     set_outdev_name  The  set_outdev_name command sets the name for the input  The name of the output    cannot exceed 15 characters in length  Use the  get_outdev_name command to retrieve  the output name     Syntax      set_outdev_name paraml    Parameters     param1 Name    Example      set_indev_name Macb
14. ling the Battery    The IR remote control unit ships with two batteries  Only one battery is required for  operation  The second battery is a spare     WARNING  Use only 3V CR2032 type batteries  Risk of explosion  if battery is replaced by an incorrect type  Dispose of used batteries    according to the instructions        1  Remove the back cover the IR Remote Control unit     2  Insert the included battery into the primary battery slot  The positive     side of the  battery should be facing up     3  Replace the back cover     NOTE  An Activity Indicator that flashes quickly while holding down  any one of the buttons indicates a low battery  Replace the battery    as soon as possible        Setting the IR Channel  In order for the included IR remote control to communicate with the 4x1 DPKVM Switcher     the IR remote control must be set to the same channel as the switcher   Use the  irrmtadd command to set the IR channel of the switcher     IR Channel DIP settings    0 ON   default  um  2            1  1 ON   1 2  2 ON  3 ON       DIP switches    S  ai    page   6    Installation    Connecting the 4x1 DPKVM Switcher    1  Connect up to four DisplayPort source devices to the DisplayPort inputs on the back  panel of the Switcher using DisplayPort cables     2  Connect a DisplayPort supported display to the DisplayPort output on the back panel  of the Switcher     Connect up to four USB host devices  computers  etc  to the USB In ports     Connect up to two USB devices  mouse
15. make changes in the hardware  packaging  and any  accompanying documentation without prior written notice        2015 Gefen  LLC  All Rights Reserved   All trademarks are the property of their respective owners     iv    Operating Notes      The 4x1 DPKVM Switcher supports pass through EDID  The Switcher will use the  EDID from the monitor connected to the output       Dual Link resolutions up to 2560 x 1600 are supported     HDCP content is not supported     The 4x1 DPKVM Switcher does not support DHCP       The default IR channel for both the Switcher and the IR Remote Control Unit is  channel 0  See Setting the IR Channel for more information     Licensing    This product uses software that is subject to open source licenses  including one or more  of the General Public License Version 2 and Version 2 1  Lesser General Public License  Version 2 1 and Version 3  BSD  and BSD style licenses  Distribution and use of this  product is subject to the license terms and limitations of liability provided in those licenses   Specific license terms and Copyright Notifications are provided in the source code    For three years from date of activation of this product  any party may request  and we   will supply  for software covered by an applicable license  e g  GPL or LGPL   a complete  machine readable copy of the corresponding open source code on a medium customarily  used for software interchange  The following software and libraries are included with this  product and subject to 
16. nds to one  of the push buttons on the front panel     For our first example  we will switch to Input 3 using the buttons on the front panel     1  Press button 3 on the front panel of the 4x1 DPKVM Switcher   2  The LED indicator for input 3 will glow bright blue on the front panel     Press button 3    LED indicates that Input  3 is the active input        page   10    Operating the 4x1 DPKVM Switcher    Switching Sources  Switching sources using the IR Remote Control    In this example  we will switch to Input 1  using the IR remote control unit     Point the IR remote control unit at the IR sensor on the front panel of the  4x1 DPKVM Switcher     If an IR Extender  Gefen part no  EXT RMT EXTIR  is being used  then point the  IR remote control unit at the sensor of the IR Extender     1   Prress button 1 on the IR Remote Control Unit  The Activity Indicator on the IR  Remote Control Unit will glow yellow  indicating that a button was pressed     2  The LED indicator  on the front panel  for Input 1 will glow bright blue     LED indicates a  button was pressed    Press button 1 on the IR  remote control unit     IR sensor    LED indicates that Input  1 is the active input        page   11       03 Advanced Operation    RS 232 and IP Configuration       RS 2321nierface Pr mS  RS 232 Settings          IP Configuration          RS 232   IP Commands       Advanced Operation    RS 232 and IP Configuration    RS 232 Interface    54321       RS 232 Controller Switcher    0 0 JO u 
17. ook     set_pass  The  set_pass command sets the Telnet password  The default password is Admin   The switcher must be rebooted after executing this command  The password cannot    exceed 20 characters in length  Use the show pass command to display the current  Telnet password     Syntax      set pass paraml    Parameters     param1 Password    Example     fset pass reindeer  Telnet password updated to  reindeer    page   23    Advanced Operation    RS 232   IP Commands     set_telnet_port  The  set_telnet_port command sets the TCP terminal server listening port     The default port setting is 23  The switcher must be rebooted after executing this  command     Syntax      set_telnet_port paraml    Parameters     param1 Port  1     65535     Example      set_telnet_port 24  New Telnet port set to  24     set_user_name  The  set_user_name command sets the Telnet user name  The user name cannot exceed    20 characters in length  The default user name is Admin  Use the  show user name  command to display the current user name     Syntax     fset user name paraml    Parameters     param1 User name    Example      set_user name Doc Holiday  Telnet username set to  Doc Holiday    page   24    Advanced Operation    RS 232   IP Commands     sgateway  The  sgateway command sets the gateway address  The gateway must be typed using    dot decimal notation  The default gateway is 192 168 1 254  The switcher must be  rebooted after executing this command     Syntax      sgateway paraml   
18. or long periods of time     Refer all servicing to qualified service personnel  Servicing is required when the  apparatus has been damaged in any way  such as power supply cord or plug is  damaged  liquid has been spilled or objects have fallen into the apparatus    the apparatus has been exposed to rain or moisture  does not operate normally   or has been dropped     Batteries that may be included with this product and or accessories should never be  exposed to open flame or excessive heat  Always dispose of used batteries  according to the instructions     4x1 DPKVM Switcher    Warranty Information    Gefen warrants the equipment it manufactures to be free from defects in material and  workmanship     If equipment fails because of such defects and Gefen is notified within two  2  years from  the date of shipment  Gefen will  at its option  repair or replace the equipment  provided  that the equipment has not been subjected to mechanical  electrical  or other abuse or  modifications  Equipment that fails under conditions other than those covered will be  repaired at the current price of parts and labor in effect at the time of repair  Such repairs  are warranted for ninety  90  days from the day of reshipment to the Buyer     This warranty is in lieu of all other warranties expressed or implied  including without  limitation  any implied warranty or merchantability or fitness for any particular purpose  all of  which are expressly disclaimed     1  Proof of sale may be requi
19. red in order to claim warranty     Customers outside the US are responsible for shipping charges to and from Gefen     Copper cables are limited to a 30 day warranty and cables must be in their original  condition     The information in this manual has been carefully checked and is believed to be accurate   However  Gefen assumes no responsibility for any inaccuracies that may be contained   in this manual  In no event will Gefen be liable for direct  indirect  special  incidental  or  consequential damages resulting from any defect or omission in this manual  even if  advised of the possibility of such damages  The technical information contained herein  regarding the features and specifications is subject to change without notice     For the latest warranty coverage information  refer to the Warranty and Return Policy under  the Support section of the Gefen Web site at www gefen com     PRODUCT REGISTRATION    Please register your product online by visiting the Register Product page under the  Support section of the Gefen Web site     4x1 DPKVM Switcher    Contacting Gefen Technical Support    Gefen  LLC   c o Customer Service  20600 Nordhoff St   Chatsworth  CA 91311    Telephone   818  772 9100   800  545 6900  Fax   818  772 9120  Email  support gefen com  Visit us on the Web  www gefen com    Technical Support Hours  8 00 AM to 5 00 PM Monday   Friday  Pacific Time    4x1 DPKVM Switcher is a trademark of Gefen  LLC     Important Notice  Gefen  LLC reserves the right to 
20. their respective open source licenses       IwIP    freeRTOS      Query    IwIP is licenced under the BSD licence     Copyright  c  2001 2004 Swedish Institute of Computer Science   All rights reserved     Redistribution and use in source and binary forms  with or without modification   are permitted provided that the following conditions are met     1  Redistributions of source code must retain the above copyright notice  this list of  conditions and the following disclaimer     2  Redistributions in binary form must reproduce the above copyright notice  this list of  conditions and the following disclaimer in the documentation and or other materials  provided with the distribution     3  The name of the author may not be used to endorse or promote products derived from  this software without specific prior written permission     THIS SOFTWARE IS PROVIDED BY THE AUTHOR  AS IS    AND ANY EXPRESS   OR IMPLIED WARRANTIES  INCLUDING  BUT NOT LIMITED TO  THE IMPLIED  WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE  ARE DISCLAIMED  IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT   INDIRECT  INCIDENTAL  SPECIAL  EXEMPLARY  OR CONSEQUENTIAL DAMAGES   INCLUDING  BUT NOT LIMITED TO  PROCUREMENT OF SUBSTITUTE GOODS OR  SERVICES  LOSS OF USE  DATA  OR PROFITS  OR BUSINESS INTERRUPTION   HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY  WHETHER IN   CONTRACT  STRICT LIABILITY  OR TORT  INCLUDING NEGLIGENCE OR  OTHERWISE  ARISING IN ANY WAY OUT OF THE USE OF THIS SOF
21. ut Connects an audio output device using a  3 5mm mini stereo cable     5 DP Out Connects to a DisplayPort output  display      Ext  IR Connect an IR extender  Gefen part no   EXT RMT EXTIR  to this jack     7 USB In  1   4  Connects up to 4 USB host devices    8 USB Out  1   2  Connect up to 2 USB devices to these  ports    9 RS 232 Connect an RS 232 cable from this port    to an RS 232 control device  This port  provides remote control of the product from  a remote location     10 Ethernet Connect an Ethernet cable from this jack to  a network in order to control the unit using  the Telnet feature     o    page   3      Getting Started       IR Remote Control Unit    Front               e  eMT 4I    Activity indicator This LED glows bright orange when a key    is pressed on the remote     Source selection buttons Used to control features in the On Screen   1  2  3  4  Display  see page 4           page   4    Getting Started    IR Remote Control Unit    Back     shown with cover removed         P N  RMT 4IR  www gefen com       DIP switch bank       Use these DIP switches to set the IR  channel of the remote  see page 5                Primary battery slot Holds the battery for operating the remote    shown without battery  Use only 3V CR2032 type batteries  Make  sure that the positive     side of the battery  is facing up     Alternate battery slot Allows for the installation of secondary   backup  battery     page   5    Getting Started    IR Remote Control Unit    Instal
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
USER MANUAL - Innovative Cleaning Equipment    Shure MX300 Series User Guide (Spanish)  Sony 530P Camcorder User Manual  Cambridge SoundWorks P460 User's Manual    SERVICE MANUAL - X-Core Technology Co., Ltd.  RIDGID 258XL User's Manual    Chapter One Your Success In Commercial Real Estate    Copyright © All rights reserved. 