1.                                                                                  Cable Routing and Layout Guidelines    Cables containing the following should be routed    Bus signals  e g  Remote I O   Data signals for PCs  programming devices  printers etc    Screened analog inputs   Unscreened DC voltages   lt   60V  in the same cable loom or cable duct  Screened process signals   lt   25 V    Unscreened AC voltages   lt   25V    Coaxial cables for monitors    DC voltages from 60 V to 400 V  unscreened  in separate cable looms or cable ducts  AC voltages from 25V to 400 V  unscreened  without minimum spacing requirements    DC and AC voltages  gt  400 V  unscreened   Telephone cables  For areas with explosion hazard    in separate cable looms or cable ducts  without minimum spacing requirements       Laying Cables Outside of Control Cabinets    All cable ducts should be constructed of electrically conducting material and connected to functional  ground at regular intervals  Cables should not be subject to mechanical loads which exceed the  manufacturer   s specifications  If this cannot be avoided  additional protective measures should be taken   such as laying the cables in a steel pipe or rugged metal duct  The pipe or duct should then be grounded  at regular intervals and protected against corrosion     12        2500 RIO Installation and Operation Guide V1 1       SPECIFICATIONS    General  Module Size  Double Wide SIMATIC   505 I O  Backplane Power Consumption  2 5 wa
2.                                                                               2 4  Configuring the Module                                                                                             Setting the RS232 Port Baud Rate  Setting the Output State on Communication Loss    2 5  Physical STAN QMO ssiri En aa SEEE aaa EREE    2 6  Connecting to the RS232 Port                                                                               6  2 7  Connecting the Remote I O Cable                                                                        7  2 9  Operation of LED Display                                      8    APPENDIX A  REMOTE I O INSTALLATION GUIDELINES  Cable Layout Planning  Cable Selection  Cable Lengths  Bus termination  Cable Routing and Layout Guidelines  Laying Cables Outside of Control Cabinets    SPECIFICA HONS u u u u u uu u u usus                        eaea                                   CTI 2500 RIO Installation and Operation Guide V1 0       CHAPTER 1  DESCRIPTION    1 1  Introduction                 The CTI 2500 RIO RS485 Remote Base Controller is a Eo  member of Control Technology s family of I O modules   1   compatible with 505 programmable controllers from   0  Siemens   and CTI  3    The 2500 RIO RS485 Remote Base Controller  RBC   allows a SIMATIC   505 I O base to function as a  remote base on the 505 Remote I O channel  The 2500   RIO is intended to be a replacement for the Siemens    505 6851 A RBC  It provides the following functio
3.          J          5           a       O               i    TX RX   8            Figure 4  Remote I O Port    CTI 2500 RIO Installation and Operation Guide V1 0                               2 8  Operation of LED Display    The LED Display is used to indicate the status of the 2500 RIO Remote Base Controller as shown in  the following table     Display Definition Communication Comment   Action  s to RBC    Module            Fully Operational        online with            Diagnostics Failure Serious malfunction  Place system in  safe state and contact CTI Technical  Support     Module Mismatch I O modules installed do not match the                 expected configuration in the CPU    No Communications   Failed There is no communication with the  CPU  Place the system in a safe state   Check power  cabling  and connection  to the CPU    RAM Parity Error None The 2500 RIO has detected an internal  RAM parity error  Serious malfunction   Place system in safe state and consult  CTI Technical Support     Standby  No None Standby RBC in dual media application   Configuration is not configured  Configure module    Address Mismatch Dual media RBC s must have identical  station address  If addresses are  equal  contact CTI Technical Support    No Configuration 2500 RIO is not configured  Configure  RBC in CPU    Watchdog Timeout None RBC reset by hardware watchdog  timeout  Serious malfunction  Place  system in safe state and consult        Technical Support    Standby  Configured Sta
4.        2500 RIO  RS485 REMOTE BASE CONTROLLER  INSTALLATION AND OPERATION GUIDE    Version 1 0  CTI Part   062 00366 010    2500RIO IOG 120805    Copyright    2005 Control Technology Inc   All rights reserved     This manual is published by Control Technology Inc   5734 Middlebrook Pike  Knoxville  TN 37921   This manual contains references to brand and product names which are trade names  trademarks   and or registered trademarks of Control Technology Inc  Siemens   and SIMATIC   are registered  trademarks of Siemens AG  Other references to brand and product names are trade names   trademarks  and or registered trademarks of their respective holders     DOCUMENT DISCLAIMER STATEMENT    Every effort has been made to ensure the accuracy of this document  however  errors do occasionally  occur  CTI provides this document on an    as 1s    basis and assumes no responsibility for direct or  consequential damages resulting from the use of this document  This document 15 provided without  express or implied warranty of any kind  including but not limited to the warranties of  merchantability or fitness for a particular purpose  This document and the products it references are  subject to change without notice  If you have a comment or discover an error  please call us toll free    at 1 800 537 8398 or email us at sales controltechnology com     REVISION HISTORY  12 08 05  ry s           PREFACE    This Installation and Operation Guide provides reference information for the CTI 2500
5.  RIO RS485  Remote Base Controller  The information in this manual 15 directed to individuals who will be  installing the module and configuring it for use with a 505 CPU from Siemens   or CTI    We assume you are familiar with the installation and operation of     SIMATIC   505 programmable controllers    Please refer to the appropriate SIMATIC   user documentation for specific information on  SIMATIC   505 programmable controllers and I O modules            2500 RIO Installation and Operation Guide V1 0       USAGE CONVENTIONS       NOTE   Notes alert the user to special features or procedures     CAUTION   Cautions alert the user to procedures that could damage equipment     WARNING   Warnings alert the user to procedures that could damage equipment and endanger the user           TABLE OF CONTENTS                     WW W    10  11  12  12    CHAPTER 1  DESCRIPTION                                              As alt OCNIC ieh uuu uu                  1 2  Communication Ports                                                       1 2 1  Serial Port  1 2 2       Port    CHAPTER 2  INSTALLATION                                             2 Ax                                  T    Lu lelaveds           Choosing Remote I O Media  Selecting a Remote Base Address  Setting Module Hardware Options  Connecting to Remote I O Cable    2 2  Power Requirements                                                                   aa                        2 3  Unpacking the Module            
6.  the module is fully seated in the slot  tighten the captive screws at the top and bottom to hold  the module in place  To remove the module from the I O base  loosen the captive screws  and then  pull the module from the base  Take care not to damage the connector at the back of the module when  inserting or removing the module     2 6  Connecting to the RS232 Port    The RS232 port 15 provided to interface to PLC programming and configuration tools such as  TISOFT      The use of this port is optional  A standard 9 pin PC RS232 serial cable can be used to  connect to the programming device or modem  The port details are shown in Figure 3     6        2500 RIO Installation and Operation Guide V1 1    9 Pin D Shell Male Connector  Compatible with standard PC Serial Port    RxD  2   TxD  3     SGND  5     N       J               lt                                       Figure 3  RS232 Serial Port    The I O Port connects the 2500 RIO to a SIMATIC   505 compatible RS485 Remote I O  channel  This enables the remote Siemens   505 CPU or CTI 2500 CPU to control the I O  modules in the base where the RBC 1s located     The Remote I O Port interface is a 9 pin D Shell connector with pinout as shown in Figure  3  Recommending wiring for the Remote I O cabling is detailed in Siemens   545 555 575  System Manual  Figure 4 shows the pinout for the I O Port     2    Connecting the Remote I O Cable    9 Pin D Shell Female Connector    GND  5     TXIRX   3                 4        O O O O 
7. 0 RIO Installation and Operation Guide V1 1    CHAPTER 2  INSTALLATION    The installation of the Model 2500 RIO RS485 Remote Base Controller consists of the following  Steps     1  Planning the installation   2  Verifying power requirements   3  Unpacking and configuring the module  4  Physical installation   5  Connecting cables   6  Checking the module operation    2 1  Installation Planning    Choosing Remote I O Media    The 2500 RIO attaches directly to the RS485 Remote I O cable using a DB9 connector  We  recommend using cable designed specifically for RS485 systems  such as Belden 3105A  See  Appendix A for information related to cable specifications  layout  and installation     Selecting a Remote Base Address    Before proceeding  you must determine what address you will assign to the RBC  Remote Base  addresses range from 1 to 15  In SIMATIC   505 systems  address 0 is reserved for the local base  where the CPU is installed  Note that each Remote Base on the Remote I O channel must have a  unique address     Setting Module Hardware Options    The RBC includes a hardware setting for selecting the state of the base discrete outputs in the event of  a loss of communication with the CPU  The module can be configured to set all outputs off  or to  leave outputs at their last states     Connecting to Remote I O Cable    The Remote I O connector should be wired as shown in Section 2 7     2 2  Power Requirements    The CTI 2500 RIO module consumes 2 5 watts of  5 VDC powe
8. ANTY SET FORTH ABOVE IN THIS ARTICLE IS THE ONLY WARRANTY CTI GRANTS  AND IT IS IN LIEU OF ANY OTHER IMPLIED OR EXPRESSED GUARANTY OR WARRANTY ON CTI  PRODUCTS  INCLUDING WITHOUT LIMITATION  ANY WARRANTY OF MERCHANTABILITY OR  OF FITNESS FOR A PARTICULAR PURPOSE AND IS IN LIEU OF ALL OBLIGATIONS OR LIABILITY  OF CTI FOR DAMAGES IN CONNECTION WITH LOSS  DELIVERY  USE OR PERFORMANCE OF CTI  PRODUCTS OR INTERRUPTION OF BUSINESS  LOSS OF USE  REVENUE OR PROFIT  IN NO  EVENT WILL CTI BE LIABLE FOR SPECIAL  INCIDENTAL  OR CONSEQUENTIAL DAMAGES     SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR  CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS  SO THE ABOVE LIMITATIONS OR  EXCLUSIONS MAY NOT APPLY TO YOU     THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS  AND YOU MAY ALSO HAVE OTHER  RIGHTS WHICH MAY VARY FROM STATE TO STATE     14        2500 RIO Installation and Operation Guide V1 1       REPAIR POLICY       In the event that the Product should fail during or after the warranty period  a Return Material Authorization   RMA  number can be requested orally or in writing from CTI main offices  Whether this equipment is 1   or  out of warranty  a Purchase Order number provided to CTI when requesting the RMA number will aid in  expediting the repair process  The RMA number that is issued and your Purchase Order number should be  referenced on the returning equipment s shipping documentation  Additionally  if the product is under  warranty  proof of purchase date and se
9. Number of Installed Feet  Meters   Drop Lines  Belden 3105         2360     _  _ 8   2000 610   x 9    H36   9                10 CTI 2500 RIO Installation and Operation Guide V1 1    Cable trunk length is measured from the CPU to the most distant base                                                                 CPU  Terminating  Resistor  Terminating  Resistor                 Trunk Length  gt a Max Trunk Length                _    T T T T T T T   lt  Total Trunk Line Length  gt           T   Terminal Block    Figure 6  Trunk Length Measurement    By using a T configuration as shown In Figure 7  the maximum trunk length can be extended to twice  the length shown in the table on the previous page                                                                 CPU  Terminating  Resistor  Terminating  Resistor  Max Trunk Length  gt  4 Max Trunk Length  T T T T T T T  Total Trunk Line Length      T   Terminal Block    Figure 7  T Connection Trunk Length    Bus termination    In order to minimize cable reflections and ensure a defined noise level on the data lines  the data transfer  cable MUST be terminated at both ends with a terminating resistor approximating the characteristic  impedance of the cable  For Belden   3105A cable  a termination resistor value of 120 ohms should  be connected across the TX RX  and TX RX  signal lines            2500 RIO Installation and Operation Guide V1 0                                                                                           
10. cts 10 material and workmanship at any time during  this  1  year warranty period  CTI will repair or replace  at its option  parts or Products found to be defective  and shipped prepaid by the customer to a designated CTI service location along with proof of purchase date and  associated serial number  Repair parts and replacement Product furnished under this warranty will be on an  exchange basis and will be either reconditioned or new  All exchanged parts or Products become the property  of CTI  Should any Product or part returned to CTI hereunder be found by CTI to be without defect  CTI will  return such Product or part to the customer     This warranty does not include repair of damage to a part or Product resulting from  failure to provide a  suitable environment as specified in applicable Product specifications  or damage caused by an accident   disaster  acts of God  neglect  abuse  misuse  transportation  alterations  attachments  accessories  supplies   non CTI parts  non CTI repairs or activities  or to any damage whose proximate cause was utilities or utility  like services  or faulty installation or maintenance done by someone other than CTI     Control Technology Inc  reserves the right to make changes to the Product      order to improve reliability   function  or design in the pursuit of providing the best possible Product  CTI assumes no responsibility for  indirect or consequential damages resulting from the use or application of this equipment     THE WARR
11. n Switches Freeze Jumper           2500 RIO Installation and Operation Guide V1 1    1  Setting the RS232 Port baud rate   2  Setting the Remote Base Controller address   3  Setting the output state on communication loss   Freeze Jumper     Figure 2 indicates the location of the RS232 port baud  rate selection switches  the RBC station address  thumbwheel  and Freeze Jumper  The remainder of this  section describes the function of the individual settings     Setting the RS232 Port Baud Rate    Switches SW1 SW4 are used for setting the baud rate  of the RS 232 serial port  The supported baud rates are  shown in the following table  All other switch  combinations are invalid     Baud Rate SW1 SW2  SW3 SW4  19200  9600    2400  1200  300       RBC Station  Address    Setting Remote base Controller Station Address    A thumbwheel switch is provided to set the base address to the 2500 RIO for Remote I O station  identification  A maximum of 15 remote bases can be connected to the CTI 2500 Series CPU or  Siemens   545 555 575 CPU     NOTE   When connecting the 2500 RIO to a       2500 Series CPU or Siemens   545 555 575 CPU  only       addresses between 1 and 15 are valid  Each installed 2500 RIO must have a unique station number     Care should be taken to prevent circumstances which cause the CPU to lose communication with the  2500 RIO while the system is operating  Loss of communication between the CPU and RBC will  cause the base to be logged off from the CPU  This can cause i
12. ndby RBC in dual media application  configured and ready to control I O       blank    No Code Displayed None Serious condition  2500 RIO is not  operational  If power to base is OK   contact        Technical Support     8        2500 RIO Installation and Operation Guide V1 1          APPENDIX A  REMOTE I O INSTALLATION GUIDELINES  These Remote I O Installation Guidelines are based on standard RS485 wiring practices  See  Chapter 6 of the SIMATIC   505 545 555 575 System Reference Manual for further details     The Remote I O cable system consists of a main trunk line and drop lines which connect the  CPU Local Base and Remote Base s  to the trunk line by means of terminal blocks as shown in                                                                      Figure 5   CPU  Terminating  Resistor  Terminating    Resistor    lt         Trunk Length  gt  lt  Max Trunk Length               T T T T T T T    lt  Total Trunk Line Length  gt    T   Terminal Block  Figure 5  Remote I O Installation   Cable Layout Planning    Use the following guidelines for planning the Remote I O cable routing and locations     e The ideal cable installation is a single  unbranched trunk line with short drop lines and  termination resistor at each end   Maximum length of a drop line should not exceed 33 feet  10 m    Drop lines less than 3 3 feet  1 m  do not count toward cable length calculations   The total length of all drop lines should be much less than the length of the trunk line   When multi
13. ns        Compatible with 505 CPUs from Siemens   and  CTI    Can be used In currently available CTI and  Siemens   4   8   and 16 slot bases   Supports communication speeds 2Mbits sec and  maximum cable distance of 1000 meters   LED display which shows error and status codes  Front panel thumbwheel switch for setting the  station address   On board RS232 port which can be used for  PLC programming and configuration           The 2500 RIO resides in SIMATIC   505 base  It  installs in the second slot from the left  adjacent to the  power supply module        Figure 1  2500 RIO Front Panel           2500 RIO Installation and Operation Guide V1 0 1    1 2  Communication Ports  The 2500 RIO RS485 RBC has two communication ports on the front panel     1 2 1  Serial Port    The RS232 port 15 provided to interface to PLC programming and configuration tools such as  TISOFT        A standard 9        PC compatible RS232 serial cable is used to connect to the  programming device or modem  The port pinout 1s provided in Section 2 6 of this manual     1 2 2  YO Port    The I O Port connects the 2500 RIO to a SIMATIC   505 compatible RS485 Remote I O  channel  This enables the remote 505 CPU to control the I O modules in the base where the  RBC 15 located     The Remote I O Port interface is a 9 pin D Shell connector as detailed in Section 2 7 of this  manual  Recommended guidelines for planning  selection  and installation of Remote I O  system is included in Appendix A     2        250
14. ntermittent process operation     WARNING   The following events will cause loss of communication with the 2500 RIO and result in the  base being logged off from the CPU     1  Duplication of the station address between RBC   s attached to the same CPU   except in dual media applications    2  Changing the thumbwheel switch station address while the system is operating     These events could cause unpredictable process operation and result in damage to  equipment and or serious injury to personnel        When a base if logged off  the CPU zeroes all image register input points associated with the base and  all outputs go to the value determined by the installed output module  Discrete outputs turn OFF  0   and Analog Word outputs are set according to the Zero Hold Last Value settings in each particular  module  Your program can monitor the CPU Status Words to detect this condition and control the  outputs from other remote bases as appropriate for the application  Details on the Status Words and  programming examples can be found in the SIMATIC   545 555 575 Programming Reference  User Manual     Setting the Output State on Communication Loss    When I O channel communication to a remote base is lost  the state of the discrete outputs 15  determined by the selection made on the 2500 RIO jumper JP1  Off Freeze   Figure 2 shows the  location of the jumper on the 2500 RIO     NOTE   The 2500 RIO ships with the FREEZE jumper in the OFF setting     If the jumper     1 is missing f
15. ple bases must be located in close proximity  connect all bases in a    daisy chain     arrangement with a single drop line     Cable Selection    Data transfer in the Remote I O systems is based on a symmetrical RS485 bus system using shielded  twisted pair cable  The cable shield 15 used to improve the immunity to electromagnetic interference   The ideal cable provides low signal attenuation for long trunk lines and flexibility for ease of  installation  The recommended cable should include the characteristics as shown in the following  table            2500 RIO Installation and Operation Guide V1 0                                                                                     Recommended    8       to 22AWG uniform   2 conductors 22A WG  030  twisted pair in  7 5mm   7x30 stranded  copper braid plus drain wire  Impedance     lt  50 pF m  Resistance of installed length   lt  characteristic impedance   1 0 dB  30 m    1MHz    Velocity of Propagation    gt  65   Operating Temperature   0 to  60   C  20 to  60   C       Cable Lengths    Maximum permissible cable length is dependent on cable characteristics and number of terminal  blocks used in the installation  Terminal blocks are used to connect drop lines and or extend Remote  I O cable trunk line  The following table contains the maximum recommended cable length  Trunk  Length   Drop Lines  for Belden   3105A cable  It is possible to have longer cable runs if larger  diameter wire is used     Maximum Cable Length in  
16. r from the backplane  Before  installing the RBC  verify that your mounting base power budget can accommodate the required  power  A good tool for performing the verification is the CTI SIMATIC   505 Replacement Guide  and Power Calculator  available from our website at    ftp   ftp controltechnology com public Download tools            2500 RIO Installation and Operation Guide V1 0 3    2 3  Unpacking the Module    Open the shipping carton and remove the special anti static bag that contains the module   After discharging any static build up  remove the module from the static bag  Do not discard the  static bag  Always use this bag for protection against static damage when the module is not inserted    into the I O base     CAUTION   The components on the 2500 RIO module printed circuit card can be damaged by static    electricity discharge  To prevent this damage  the module is shipped in a special anti static  bag  Static control precautions should be followed when removing the module from the bag       and when handling the printed circuit card during configuration     2 4  Configuring the Module    There are three steps to configuring the module and making it fully operational     Figure 2  Switch Locations               141665 p       a Ret  2            R62 F         pia       C71           I    012 413 03 0            RS 232 BAUD           SWI 512 SW3 4   w2            9600 1  2400 0  1200  1  300    C73          1  1  at                               Baud 6  Selectio
17. rial number must accompany the returned equipment  The current  repair and or exchange rates can be obtained by contacting CTI s main office at 1 800 537 8398     When returning any module to CTI  follow proper static control precautions  Keep the module away from  polyethylene products  polystyrene products and all other static producing materials  Packing the module in its  original conductive bag 15 the preferred way to control static problems during shipment  Failure to observe  static control precautions may void the warranty  For additional information on static control precautions   contact CTI at 1 800 537 8398            2500 RIO Installation and Operation Guide V1 0 15    
18. rom the board  the 2500 RIO defaults to the OFF setting        For discrete output modules  the state of the outputs is determined solely by the position of the  Off Freeze jumper JP1 on the 2500 RIO            2500 RIO Installation and Operation Guide V1 0 5    For analog word output modules  the state of the outputs is influenced not only by the position of the  Off Freeze jumper but by the output module   s  Zero Hold Last Value  selection  if the module has  that option  See the table below     RBC Off Freeze Analog Word Module Analog Word Output  Selection Zero Hold Selection State    Hold Last Value     see the user manual of your analog word output module for details       Notice that the FREEZE option on the RBC overrides the Zero selection on the analog word output  module  likewise  when Hold Last Value is selected on the analog word output module  that selection  overrides the OFF option on the RBC jumper     WARNING   If the RBC fails or loses power during system operation  all outputs will turn OFF 0     regardless of the Freeze Jumper setting  This could result in damage to equipment and or  serious injury to personnel        2 5  Physical Installation    To insert the module into the I O base  hold the top and bottom of the bezel and slide the module  carefully into the slot  pushing it all the way into the base  If you have inserted the module correctly   you will feel a slight increase in resistance as the module mates with the base backplane connector   Once
19. tts    Compatibility  SIMATIC   505 and        2500 CPU   s  All currently available        and Siemens   505 4   8   and 16 slot bases  Single and Dual Media configurations    Display  Shows RBC status and error codes    Output State Selection  Determines state of outputs when I O channel communication is lost   OFF All outputs are turned off  FREEZE      outputs hold their last value    Hardware User Configuration Options   RS232 Serial Port baud rate  dipswitch   RBC Station Address  thumbwheel     Diagnostic Data   RBC Status Indication in CPU Status Word and Front Panel LED Display    Ports  Remote I O  9 Pin D Shell Female Connecter    RS232 Serial  9 Pin D Shell Male Connecter  PC compatible pinout    Environmental   Operating Temperature  0   to 60   C  32   to 185   F    Storage Temperature   40   to 85   C   40   to 185   F    Humidity  5  to 95   non condensing   Agency Approvals Pending  UL  ULC  CE  Class   Division 2 Hazardous Location  Shipping Weight  1 5 Ib   0 68 Kg            2500 RIO Installation and Operation Guide V1 0 13       LIMITED PRODUCT WARRANTY       CTI warrants that this CTI Industrial Product shall be free from defects in material and workmanship for a  period of one  1  year after purchase from CTI or from an authorized CTI Industrial Distributor  This CTI  Industrial Product will be newly manufactured from new and or serviceable used parts which are equal to new  in the Product     Should this CTI Industrial Product fail to be free from defe
    