ZG1163R English Manual
Contents
1. we COS BO re COS w OUx BUTTON rae CUS mm BO 1 Press Mode The RcFS icon flashes 2 Press Enter the icon no shows on the LCD Press the Up Down to select the no yes 3 After selecting press Enter to save the setting Note If the user sets the data or calibrates the ZG1163R incorrectly use the RcFS recover the factory Setting to come back the default factory setting Method Dual Beam NDIR Non Dispersive Infrared Display LCD Independent CO2 RH and Temperature readings Calculates and Displays Ventilation Rates Sample Method Diffusion or flow through 50 200 ml min CO2 Temperature amp RH Specification CO2 Specification CO2 Specification Display Resolution tppmat0 7 000ppn 5ppm at 1 001 2000ppm 10pm at 2001 8000ppm Accuracy 0 2 000ppm 70 ppm or 5 of reading whichever is greater over 2000ppm 7 Typ 0 2 of reading per C or 2 ppm per C whichever is greater referenced to 25 C Pressure Dependence 049 ot readng per mmHg Coveted va wserinputioratiude OOOO Repoatabiiy 220pm 400pm Response Time About 2min for 6s of step change Warm UpTime lt S0seoonsat 22 Zone LED Display Green lt 800pprn Yelow 80 1200ppm fed gt 1200ppm_ Temperature Specification Temperature Range 0010 500 BZF 1o 22 Fdslay Display Reson orcora Dispiay Options eor Response Time 2030 minutes case must equalize wih envonment 1 C 2 F When the fan blows to t
2. Adjust altitude step 100m 500ft by up down button 4 Press Enter again to save the data Setting the ALARM 1 level UBS mes GS rae CUI m Olx we CUD a BU 1 Press Mode the ALARM 1 icon flashes 2 Press Enter Using the Up Down to set the parameter the default ALARM 1 is 800 ppm 3 Press Enter again to save the data Note 1 When CO2 Alarm level is 1 000 ppm the interval is 100ppm when the CO2 Alarm level is lt 1 000 ppm the interval is 50 ppm 2 After setting with new alarm level parameter the green LED will light when CO2 concentration below the alarm 1 level Setting the ALARM 2 level o Woo TEMP cu 5 j RH 5 Us TEMP cos JA ALARM 2 1 Press Mode the ALARM 2 icon flashes 2 Press Enter Using the Up Down to set the parameter the default ALARM 2 is 1200 ppm 3 Press Enter again to save the data Note 1 When CO2 Alarm level is 1 000 ppm the interval is 100ppm when the CO2 Alarm level is lt 1 000 ppm the interval is 50 ppm 2 After setting with new alarm level parameter the green LED will light when CO2 concentration below the alarm1 level The red LED will light when CO2 concentration exceeds the alarm 2 level the yellow LED will light when CO2 concentration is between the alarm1 level and the alarm 2 level Using the OUTSIDE mode o MEEA MEGA IE Coi re i L PPM PPM eS C0 LI PPM TEMP PDS a 60 TEMP PDS a 60 IDB Smere GUTSIDE OUTSIDE 1 Press Mode the
3. OUTSIDE icon flashes 2 Press Enter shows OUTSIDE CO2 and ppm flashes Press the Up Down to adjust the data 3 Press Enter to save the setting After the modification the VENT Rate will change Note Ventilation rate represents how much air is introduced into the indoor space from outside Low numbers indicate low ventilation rates and potentially poor air quality High levels indicate excessive ventilation and potential excessive energy usage To obtain an accurate measurement reading should be taken 2 3 hours after occupancy has stabilized in a space or at a peak in daily CO2 concentrations For indoor air quality control CO2 value is an indicator of ventilation rate 400ppm Parts Per Million is the default CO2 concentration outside according to ASHRAE American Society of Heating Refrigeration and Air conditioning Engineers Using the CALI calibration mode GAL CALI 4 4 IM 3 FI 5 CO it Hie Gen Ee cael CO LI H Om i CO tL k Oem rae CUD m OUs we CUI m OU UO Sma BU 1 Press Mode The CALI icon flashes 2 Press Enter the CALI icon on the display Adjust the CO2 reading by Up Down button 3 Press Mode for more than 10sec CALIBRATING flashes Calibration will be done automatically after about 3 minute and the LCD will display Pass or Fail If it shows Fail please try again Using the LOG mode Log LOG 4 Inco 4 noo 4 ioc d co I SE a HL m a e LS iii X MODE P i rr CUS OUx BU
4. will not response during warm up Temperature C F RH and Ventilation Rate 4 Hata 4 ICC 4 mE OR 4 Inn co ILI ep CO TLS co ILI e es ee Oo ua UP cb UP me COS mm Ux we 19 a 60 Burron 199 n 6G BUTTON tae GUS a OU 1 Press up down to select the temperature RH and ventilation rate modes 2 When pressing up button the LCD display sequence is Temp C gt Temp F gt Vent Rate Ips gt Vent Rate cfm p When pressing down button The LCD display sequence is reverse Note Temp C refers to Temperature in Celsius Temp F refers to Temperature in Fahrenheit Vent Rate lps refers to Liter Per Second Per Person Vent Rate cfm p refers to Cubic Feet Per Minute Per Person Using the MUTE function 4 IE Cers 4 IIE Co 4 IIE Cea 4 ICO co LJ i eos Ue tees cor EO EEE ie TU S ENTER TEMP 205 RH b0 TE cu5 RH bo BUTTON TEMP oF F RH 60 we ON RH 6G v UO we 205 m 60s 1 Press Mode the speaker icon flashes simultaneously 2 Press Enter use up down to select the on off 3 Press Enter again to save the data Note The factory setting with alarm is buzzer off user can set the alarm on off under MUTE function Using the ALTI mode o S res 2 EBA pess 9 TB Gam 205 60 ce PNS n 60 O a 60 ALTI ALTI 1 Press Mode the ALTI icon flashes 2 Press Enter ALTI shows on the display press the mode button to alter between the m meter and ft feet 3
5. TTON COS es 60 IN ee CUS mm OU 1 Press Mode LOG icon flashes 2 Press Enter CO2 reading and Temperature show on the LCD 3 Press Up Down to page up down the reading Note With the Built in Datalogger ZG1163R can provide the past CO2 temperature and RH reading within the past 24 hours The log interval is 30 minutes per data ZG1163R is connected with power and used for the first time If the working time is more than 30 minutes ZG1163R will have CO2 RH and temperature reading in datalogger if the working time is less than 30 minutes the LCD will display NULL while using the LOG function Using the MAX MIN mode MAX MIN MAX MAXMIN o BS ress GGA o IMEA press 9 i965 ai MODE P UF or Down TEMP eS a bus BUTTON TEMP 205 za bux 106 Hag E0 BUTTON Chr T RH 60 Ci l k 1 Press Mode the MAX MIN icon flashes 2 Press Enter the MAX and MIN CO2 reading alternatively shows 3 Press Down and the CLr will flash on the LCD Press Enter to CLEAR the MAX and MIN record Note With the Built in MAX MIN mode ZG1163R can provide the Maximum and Minimum CO2 readings since the device has last been turned on If users press up down to clear the MAX and MIN CO2 reading record ZG1163R will provide the new MAX and MIN CO2 reading from that time Using the RcFS Mode o EG Mi IEE 4 gt 4 UCE PPM PRESS bin H PPM m m PRESS MODE g ENTE UP or Down P we CUS wm OUx BUTTON
6. ZG1163R CO2 and Temperature Monitor Operating Instructions Product Overview Thank you for selecting ZG1163R desktop CO2 monitor ZG1163R CO2 monitor is smart compact and easy to use In addition to measuring the CO2 concentration ZG1163R can also measure the ambient temperature and the relative humidity This product is developed to detect the presence of CO2 in ambient air and help people to take care of Indoor Air Quality ZG1163R can be widely used in the office building school exhibition shopping mall meeting room fitness center restaurant and other pubic place where personal comfort healthy is important Features Mi The built in Data logger can store 48 sets of CO2 and temperature and RH in the past 24 hours one log per 30 minutes Vi Max Min mode can record the maximum and minimum concentration of CO2 since the device has been last turned on MV The Alarm mode the Alarm Level can be adjustable by user Mi The RCFS Mode can recover the original factory settings after the CO2 device has been recalibrated altered or damaged 1 Enter Button 4 Mode Button 7 Yellow LED Display 800 1200ppm 10 Power inlet 2 Down Button 5 LCD displa 8 Red LED Display gt 1200ppm 11 RJ45 socket only for factory use 3 Up Button 6 Green LED Display lt 800ppm 9 Gas Entry Hole 12 Ventilation Slots RcFS MAX MIN LOG CALIBRATING MCT gt g9 WARMUP VENT en c ga E m U Jrew RH Uy MUTE ALTI ALARM 12 OUTSIDE Display featur
7. es and modes Mode Functions There are several Modes which can be adjusted by user These modes are Mute Mode ALTI Mode ALARM 1 Mode ALARM 2 Mode OUTSIDE Mode CALI Mode LOG Mode MaxMin Mode and RcFS Mode in sequence l Compensate the pressure 3 The beep alarm can be setting nA F L Leu ALTI changes with appropriate i by Eeu on off under Mute Mode altitude of location when nce nm nee n ge CUS w BU measure we CUI m OUs 4 gt ALARM he first alarm level can be CO i 4 L u ALARM2 The second alarm level can be H L Eeu adjusted by user 7 adjusted by user ne n nce n TEMP CUI e b Lis C03 en Ls GALI Modify the outside CO2 ITT n peu Calibrate the sensor while the 7 c ef OUTSIDE concentration for calculating co LI reading deviates from the tL the ventilation rate ee CUS 60 actual CO2 concentration ens 6G QUTSIDE J MAXMIN Show the past CO2 4 IM Show the Max and Min CO2 IFT a D 4 reading before being cleared or CO Ll D9 Rare 4 IM 3 Recover the factory setting to co ILI 4 C PPM cancel customize setting LOG Temperature and RH records in the past 24 hours 205 60 after Power On o 205 6B we CUI m OUx Safety Instructions Warning Your safety is very important to us To ensure to use the product correctly and safely we would like to draw your attention to read the warning and entire User Manual before using the product These are importan
8. he device directly the accuracy of temperature is 1 5 degC RH Speciation Operating Conditions WessuementRenge 20 80 RH Operating Temperature 0 C 1050C GF 1122F Depay Resoun rn humidty Range 0 95 AH non condensing rog f SRG Storage Conditions Responsen lt Sminfor S oofstep change Storage Temperature 20 C 10 60 CCA F10 10 Power Supply 100 240 VAC 50 60 Hz Power Supply 6 VDC from external AC DC adapter which is included in package Use specified AC adapter only ReFa MAXMINLOG CALIBRATING s 1065 WARMUP re TEMP U Sm at 6 Lis MUTE LARA 2 OUTSIDE 1235 46 Fault Codes amp Troubleshooting Guide This section includes a list of Frequently Asked Questions for problems you may encounter with the ZG1163R CO2 Monitor The ambient temperature has exceeded the operating This error will clear when the temperature returns to the range between 0 C to temperature range 0 C to 50 C 32 F to 122 F 50 C 32 F to 122 F Please reconnect AC adapter to ZG1163R CO2 Monitor If the Err5 Err6 still appears please contact the Service Department for further assistance Radiant Innovation Inc Http www ZyAura com Zy A ur a 1F No 3 Industrial East 9th Road Science Based Industrial Park HsinChu Taiwan 300 AC Ey F Monitor the invisible Ref No 012013
9. t safety information and should be observed at all times 1 Please handle the devices lightly do not subject the product to impact or shock Otherwise this may cause the accuracy drift 2 Do not immerse the product in water Water can cause electric shock fire or malfunction which may result in damage 3 Do not keep the product under the hot and moisture environment Keep the product away form the heat source or near water 4 Please use only the included power adaptor Improper power adaptor or power sources can cause serious damage to the product or result in injury or death to the user Caring for product To ensure you receive the maximum benefit from using this product please observe the follow guidelines 1 Cleaning Disconnect the power before clean Use a damp cloth do not use the liquid cleaning agent such as benzene thinner or aerosols 2 Repair Do not attempt to repair the product or modify the circuitry by yourself Please contact with the local dealer or a qualified repairman if the product needs servicing 3 Air diffusion The ventilation slots on the housing are designed for CO2 diffusion so these ventilation slots should not be blocked Customize Settings When the power has been connected The ZG1163R CO2 monitor will begin to work In order to meet your personal requirements it is advisable to set up the customizing parameters WarmUp It lasts approximately 1min before WARM UP disappears all MODE functions
Download Pdf Manuals
Related Search
Related Contents
128,000円 携帯用放射線測定器MKS-05 注文書 Brandt ME645WE1 microwave diagramas - Lincoln Electric BR87 User Manual 6-2015 V15 Manuale del prodotto - Meccanica Benassi Spa iida Mobile pico projector 取扱説明書 RFQ - Gseb.com Zanussi ZQS 6124 Instruction Booklet 1.877.766.5412 - PowerMeterStore.com Initial IDM-1731 Portable DVD Player with Screen Copyright © All rights reserved.