Home

Intelligent Mega-pixel NVR User Manual

image

Contents

1. Schedule Record according to the configuration Manual Click the all button and the according channel is recording no matter the channel in any state Stop Click the stop button and the according channel stops recording no matter the channel in any state 3 5 4 Alarm output 113 3 113 3 Please check current channel status o means it is not in alarming status e means it is in alarming status You can use desktop shortcut menu or click main menu gt alarm function gt alarm output to enter the alarm output interface Alarm Output Alarm Type Configuration Manual Sto p Status Picture 3 9 alarm output Configuration Alarm is on according to the configuration Manual Click the all button and the according channel is alarming no matter the channel in any state Stop 1 Click the stop button and the according channel stops alarming no matter the channel in any state 21 NR USOT NA a V1 0 3 5 5 PTZ control PTZ control is a little different between hybrid mode amp full digital mode Digital channel the digital channel need link PTZ the remote device should connect with PTZ and with protocol correctly set also Analog channel Only when the device is connect with PTZ and configure protocol correctly is ok Operation interface is as followed The functions include PTZ direction control step zoom focus iris setup operation patrol between spots trail patr
2. Pic 4 50 add group Delete User Delete the current user Choose the user and click delete user button Delete Group Delete the current group Choose the group and click delete group button 75 NYR USE VIO Main Menu gt Advanced gt Account gt Delete EAS Name admin Memo administrator group Pic 4 51 Delete Group 4 5 3 Online user To check the information of network user that connected with local device also can tick the selected user to break up connection make y at the box then the user will be frozen after connection stopped and will not log in until device reboot e Main Menu gt Advanced gt Online User User Name Login Type Disconnect Cancel Pic 4 52 online user 4 5 4 TV adjust Refer to chapter 3 5 7 76 NR PS Ng ia V1 0 4 5 5 Auto Maintain The user can set the time to auto reboot and auto delete file F S Main Menu gt Advanced gt AutoMaintai Auto Reboot Systeni Every Thursday fa at 01 00 E Auto Delete Old Files Never 0 E Picture 4 39 Auto maintain 4 5 6 Restore The system restore to the default You can choose the items according to the menu Main Menu gt Advanced gt Restore Please select setting entries that you want to default Select all a General 0O Encode O Record Config 2 Alarm Set O NetWork C NetService GUI Display a RS232 O Account hh The Configuration of Channel Encoding Channel title Time title Regional
3. Bit Rate Type JYou can choose limited code stream or variable code stream When you choose the variable code stream there are six image quality options under the limited code stream you can choose the code stream manually Bit Rate Set the code stream value to modify the image quality The larger code stream value the better image quality 1080P 1024 8192kbsp 720P 1024 4096kbps 960H 869 4096kbps D1 512 2560kbps HD1 51 NR SP Ng a V1 0 384 2048kbps CIF 64 1024kbps QCIF 64 512kbps Frame Interval can choose the range 2 12s Video Audio When the icons are all in reverse displayed the video file is video and audio multiplex stream Extra stream Settings Extra stream is used for client side monitoring amp mobile monitoring Channel title select channel title and then to choose whether need enable video amp audio The resolution frame rate bit rate type settings is the same as main stream 4 4 3 Network setup E Main Menu gt System gt Network Net Card Wire Netcare DHCP Enable IP Address 192 168 1 10 Subnet Mask 2595 255 Gateway 192 168 Primary DNS 192 168 Secondary DNS 8 8 Media Port 34567 HTTF Port 80 HS Download Transfer Policy Quality Prefe Picture4 21 Network Net Card You can choose cable network card or wireless network card DHCP Enable Obtain IP address automatically not suggested Note DHCP server is preinstalled IP address Set the IP address
4. Break the connection with the already login user Lock the account Online user after break until booting up again Adjust upside downside nearside starboard distance black margin Output adjust vertical amp horizontal Note only analog channel have black margin vertical amp horizontal Automatic Management Set automatic reboot system and automatic deleting files tools maintenance Resume setup state common setup code setup recording setup Restore alarm setup network setup network service preview playback serial port setup user management Export the device s log or configuration to external device like USB Import Export flash disk Input the configuration with external device like USB flash disk Hard disk Display hard disk capability and recording time information System BPS Display code stream information information Log Clear all log information according to the log video and time information 32 NR Sa dia V1 0 Edition Display edition information information Logout shut down or reboot Note Part Models have no shut Shut down down function 4 2 Record Operations related to record including Record Playback Backup Screen shot only Hybrid mode and full analog have 4 2 1 Record Configuration set the recording parameters in the surveillance channel The system is set 24 hours consecutive recording in the first startup You can enter main menu gt recordi
5. Picture 4 29 ARSP Type choose DNS Enable m means it is chosen Sever IP IP address of DDNS server Port Port No of device related DDNS server listen port User name the user name that device can log in DDNS server Password the password related to the user name Refresh cycle Time interval between device and DDNS when chynchronously Note Please set up server before using DDNS Alarm center When alarm occurring report alarm information to alarm server AlarmServer Protocol Type GENERAL Enable ar Server Name AlarmServer Port 15002 Alarm report Log report Pic 4 30 alarm server setting Protocol type GENERAL Enable To tick it means enable Server IP IP address of Alarm Server 58 NR SP NA dia V1 0 Port Device Port No Alarm Report Tick it means to report alarm information to server Log Report Tick it means to report log to server Wireless Config ADSL through 3G net card use CMS to visit and config the device Main Menu gt System gt NetService gt Wireless Config Enable Type Wireless AP AccessPoint e Dial Number 1777 User Name iS o Password 6060500000 IP Address Enable Choose Enable to make all settings available Type Dial type default AUTO Wireless AP 3G access point Dial Number 3G Dial Number User Name User name of 3G Password Password of dial user IP Address IP address got from dial Note Parts models don t support
6. Remark when the current resolution is over the max resolution that the channel supported then 71 NR USOT Ng a V1 0 a red X will be shown on the preview image for example Under full digital channel mode Max resolution of channel 3 is D1 if it was connected to a device with resolution over D1 such as 960H you will see below pic Channel mode Channellype Analog channels Digital channels 080P 720P 960H D1 HD1 CIF 1080P 720P 960H D1 HD1 CIF 16 0 o 0 0 0 16 O O O 0 0 4 o 0 o O O ih OOOOO ehehene cocoon A 22 dE E 1 2 Noa Head SN Nao a oa Ei PP Ao al i 00OMoO JM000 0 0 0 0 0 o 0 0 0 0 ji SocoooMoocoocoo a ET O i O Remark this series of product with full analog channel mode hybrid mode and full digital mode and different model with different channel mode user can shift the mode freely if necessary 4 5 Advanced Manage tools menu including HDD manage account manage online user output adjust auto maintain upgrade 4 5 1 HDD Manage Configure and manage the hard disk The menu displays current hard disk information hard disk number input port type status and overall capability The operation include setup the write read disk read only disk redundant disk hard disk format resume default Choose the hard disk and click the right function button to execute 12 NR SP NA ia V1 0 Note Read Write Disk The
7. shot PTZ patrol buzz email and FTP upload Set camera mask alarm channel sensitivity linkage parameters Video defending time section alarm output screen hint recording screen blind shot PTZ patrol buzz email and FTP upload Alarm set video loss alarm channel linkage parameters defending time Video section alarm output screen hint recording screen shot PTZ patrol loss buzz email and FTP upload Set alarm input channel equipment type linkage parameters Alarm defending time section alarm output screen hint recording screen input shot PTZ patrol buzz email and FTP upload Alarm output Set alarm mode configuration manual shut down NVR User Manual sssssnnencnnnnees Exception handling Intelligent analysis General configuration Encode configuration Network configuration system configuration GUI display PTZ configuration RS485 Device Serial port Configuration RS232 No HDD HDD error HDD capacity not enough network cut IP Conflict linkage parameters screen hint or buzz Set algorithm rule trajectory display sensitivity minimum pixel alert mode and setting linkage parameters period alarm output the screen prompt record PTZ tour buzzer EMAIL FTP upload Note Part models support this function Set system time data format language hard disk full time operation machine number video format output mode summertime st
8. Default 192 168 1 10 Subnet mask Set the subnet mask code Default 255 255 255 0 Gateway Set the default gateway Default 192 168 1 1 DNS setup Domain Name Server It translates the domain name into IP address The IP address is offered by network provider The address must be set and reboot then it works Media port Default 34567 52 NR PS NA a V1 0 HTTP port Default 80 HS Download Transfer Policy There are three strategies self adaption image quality precedence and fluency precedence The code stream will adjust according to the setup Self adaption is the tradeoff between the image quality precedence and fluency precedence Fluency precedence and self adaption are valid only when the assistant code stream is turned on Otherwise image quality precedence is valid 4 4 4 NetService Choose the network service option and click the set button to configure the advanced network functions or double click the service button to configure the parameters man Menu gt System gt Netservice IN et Server Net Server Info PPPoE INTP EMAIL IP FILTER IDDNS DNS Set Invalid Ll 0 FTP ARSP 1 xmsecu com 15000 AlarmServer 1 192 168 0 101 Wireless Config Not enabled Mobile Monitor 0 34599 Wifi BIO IRTSP 1 554 Cloud Enable Picture 4 22 NetService PPPOE setup Main Menu gt System gt NetService gt RPPOF Enable User Name Password IP Address Picture4 23 PPPOE Enable
9. HETSuveillance WER Bicrosotft Internet Explorer HEF see ER EAM OAD TATI AERD CH GAE O PEO See vue OC B DED ABE CD El http oumeye net wi deor index jsp mactOeel edi Sechusername admin amp password rane a EBACE ai NetSurveillance ee E CAMO2 CAMO3 CAMO4 CAMOS camoc A E ES O ee CAMOT CAMOS CAMOS9 CAM10 CAM11 CAM12 CAM13 CAM 14 CAM15 00000000000000 00 gt 0000000000000000 0000000000000000 CAM16 lt aoe Pic 5 8 monitor page log in by device 6 FAQ and maintenance 6 1 FAQ If the problems are not listed please contact the local service or call the HQ service We are willing to offer the service Ds The NVR can not boot up normally Possible reasons are as followed 1 The power supply is not correct 2 Switch power supply line is not in good connection 3 Switch power supply is damaged 4 The program updating is wrong 5 The hard disk is damaged or the hard disk lines are broken 6 The front panel is damaged 7 The main board of the NVR is damaged 86 2 NVR USE Nada ci V1 0 The NVR reboots automatically or stops working after boot up a few minutes Possible reasons are as followed 1 2 5 6 The input voltage is not stable or too low The hard disk is damaged or the hard disk lines are broken The power of the switch power supply is low Frontal video signal is not stable Bad heat radiator or too much dust
10. Reversem means choose setting can become effective 53 NR USE Ia V1 0 Input the user name and password that ISP Internet service provider provides After saving it reboot up your system Then the NVR will build a network connection based on PPPoE The IP address will change into dynamic IP address after above operation is well done Operation After PPPoE dialing successfully look up the IP address in the IP address and obtain the current IP address Then use this IP address to visit the NVR through user port NTP setup peee Z Main Menu gt System gt NetService gt N TR Enable Server IP NTP Port gt 3 Time Zone GMT 08 00 Update Period min Picture 4 24 NTP The NTP server must be installed in the PC Enable Reverseamean choose setting can become effective Host computer IP Input the IP address installed NTP server Port Default 123 You can set the port according to NTP server Time zone London GMT 0 Berlin GMT 1 Cairo GMT 2 Moscow GMT 3 New Delhi GMT 5 Bangkok GMT 7 Hongkong Beijing GMT 8 Tokyo GMT 9 Sydney GMT 10 Hawaii GMT 10 Alaska GMT 9 Pacific time GMT 8 American mountain time GMT 7 American mid time GMT 6 American eastern time GMT 5 Atlantic time GMT 4 Brazil GMT 3 Atlantic mid time GMT 2 Update Period The same with the NTP server check interval Default 10minutes EMAIL setup If the alarm is turned on or the alarm linkage photos are taken send an email about the alarm information and
11. nder Hybrid full analog mode Network Net service GUI display PTZ configure RS485 device RS232 Tour setup Spot and digital 4 4 1 General System Time 2001 01 12 20 21 50 Date Format YY YY MM C MAA Date Separator X Time Format 24 HOUR la Language ENGLISH HDD Full Overwrite x DVR No 0 Video Standard PAL Auto Logout 0 Machine Name LocalHost Picture 4 17 General setup 49 NR PSP NA da V1 0 System time Set the system data and time Date format Choose the data format YMD MDY DMY Date Separator Choose list separator of the data format Time Format Choose time format 24 hour or 12 hour Language support 29 language at present Arabic Czech English Finnish Greek Indonesian Italian Japanese Portuguese Russian Thai T Chin ese S Chinese Turkish Brazilian Bulgarian Farsi French German Hebrew Hungarian Polish Romanian Spani sh Swedish Vietnamese HDD full Choose stop record Stop recording when the hard disk is full Choose overwrite Cover the earliest recording files and continue recording when the hard disk is full NVR No Only when the address button in the remote controller and the corresponding NVR number is matched the remote operation is valid Video Standard PAL or NTSC Auto Logout Set the latency time in 0 60 O means no latency time Machine Name Can setting the device s name DST Choose the summer time option and pop the dialog box as followed E
12. 12 00 00 End Time i 00 00 2010 08 12 10 31 49 Log In 2010 08 12 10 31 50 RecoverTime 2010 08 12 10 32 30 Log Out 2010 08 12 103230 Log In User admin Logl 2010 08 12 10 32 38 Save Configuratio Location 2010 08 12 10 32 38 Save Configuratio Regular 2010 08 12 10 32 39 Shut Down 2010 E Pic 4 60 Log information 4 6 4 Version Display the basic information such as hardware information software version issue date serial number NAT status and so on enu into gt Version Record Channel 8 Extra Channel 0 Alarm In z Alarm Output 1 System 4 00 R10 00000002 1 Build Date 2012 10 26 09 00 26 MAC 260040620002 SerialNo 28822101 bdb62d13 Status 209 Nat status Connecting Nat status code 1 202 130 112 247 Pic 4 61 version information 4 7 Shut down system Refer to chapter 3 5 8 81 NR SN ia V1 0 Chapter 5 Cloud Technology Basic Operation 5 1 Cloud technology monitor Cloud technology make the device one step on net greatly bring convenience for customer to monitor via wide area network this technology is using the serial no to visit device Remark the device that using cloud technology should be in the WAN Wide Area Network firstly gt Check the connecting status of cloud technology Connect device to WAN firstly then enter Main menu gt Info gt Version to check whether the device successfully connect to the cloud server or not A Main Menu gt Info gt Version A Main
13. 34 ZO A NE 34 A SAN F UNC O O O ER O 37 Ao MOTON DEIC emer e em ne rte Ore rom OPN UPD CTU noo EW ORTON NK EW OREO BOC re ERO ERI IC Sr ER NT EOE 37 AS 2 MAC DINA AE 41 o SO A te ee ee ee ree ee ee er eee ee eee eee eer eee 42 NVR US Nada ca V1 0 AS ASA NM MID U E SS ES alsa Mea Staci sda Sioa aioe tas esata eas 43 AYE VAN HI OIG OU NO 45 Hea PAO MONA Al RR 45 TF JY AC S116 r gt YS Een nO PO o 45 A ASV SICIM OS 49 1 GENETTA eerie O 49 4 42 ENCOUS SOU Dina sia 51 ak NGIWO A NO te oP no RE NTR eT OU SCE RPE RN EE 52 AA ANSIA is 53 AS MS ii A E N T A cee iio ds 62 AAO PTZ GEVICSIIRSAGS de Indi llas 63 AA SL a 65 A He SEMPRE NTRS PSE SNOT RESTRIC N 65 FAL SON OM OUI Geaen n N eric 66 AO han imMman aiii ia 67 BZ MINT MEN A OO I2 45 HDD Manda Sais T2 ATOZ AA COT E A T E A T E E E OAA 73 Pe DNC A RT 76 AOA A O 76 AD PAULO LAV AINA a A eee 71 ORO O O o no A A A 17 E A II O O E 78 Ao Fam 8 8 BY EXODO Maldita 78 AM ios 79 kO FD WMO nin 80 A BER AREA 81 POS EO A OO 81 AO O ai S 82 A UIE CLOW INS Soo orcas 82 Chapter 5 Cloud Technology Basic Operati0D occcnooncccccnononacncononananonononananoconnnnnnnoconnnnnnnncnnnnnnnoconanananonos 82 O ay Ogre ge Ml apt a a or naaa 86 O A A 86 0 21 Maintenance notte ene tene boton ta siean baina o Denia 93 Appendix 1 Remote controller Operati0ON ooooccccccccncnnnnnanananananananononocononononananannnnon
14. Buzzer FIP upload Video Blind in Hybrid mode 4 Main Menu gt Alarm gt Video Blind Channel 1 Enable Period Sa Alarm Output Delay Record Channel Tour PTZ Activation PB Delay Show Message send Email Buzzer FIF upload Video blind in full digital NVR mode Pic 4 8 Video blind Set method refer to chapter 4 3 1 Motion detect 4 3 3 Video Loss When the equipment can not obtain the channel video signal the video loss alarm is turned on and the linkage function is turned on Same as motion detect function video loss is different between Hybrid mode amp Full digital mode Digital channel not only to enable video loss function at local side but also to enable the remote device that was connected when remote device with video loss local side will start alarm recording otherwise this function is not enable Hybrid mode only need to enable video loss function at local side Note Advanced button is the same as right click 42 NR USE Id ia V1 0 AS A EA ARO SIAF Video Loss a Channel Enable Period sa Alarm Output a Delay 10 Sec Record Channel EECCA Tour WAIVE EME SIMWiitetstststs PTZ Activation MBA Delay EC Show Message O Send Email Buzzer E FTP upload O A Tey PA A A Aea Alarm gt Video Loss Channel Enable Period e Alarm Output 1 Delay 10 Sec Record Channel 7 2 3 4 5 6 7 8l sliid Tour fabada PTZ Activation MEA
15. NVR User Manual sressessrersesesseereeesseenseseseesssnesnnsnnsnnssneensennsaneeesteesseeessensnneesseeeseeesseesseeesseetseeeeeeee V1 0 2 Scan Calls In Picture 3 10 click Page Shift button then enter PTZ control menu as shown in Picture 3 12 Please input the number of scan in the value blank then click Scan button PTZ begins to work on the scan line Click Stop button to stop 4 Boundary Scan In a horizontal line set up a line call scan PZT repeat operation according to the route 1 Boundary Scan setup Set a period of horizontal curve for PTZ search path the steps are as follows Step1 In Picture 3 10 click Direction button to turn the PTZ to preset direction then click Setup button enter Picture 3 15 select the left boundary return to Picture 3 10 Step2 Please click direction arrows to adjust PTZ direction click Setup button enter Picture3 15 then select the right boundary return to Picture 3 10 Step3 Complete setup that is the position of left and right boundary Note when the left and right scan in one horizontal the PTZ will cycle rotate from left scan along the reverse direction to the right scan When the left and right scan not in the same horizontal the PTZ will regard the end of horizontal line which connect to left scan as right scan cycle rotate from left scan along the reverse direction to the right scan PTZ Config Function Preset Preset interval Left Right scan setting button Patrol No Line scan
16. User can input remote channel title from the device that you want to connect remotely Stream Default is main stream do not support extra stream at present Device address IP address of device Port Default is 34567 User name Default is admin Remark click search will show all the devices that searched out user can choose any of the device that you like ss configuration Configur name ich ConfigO IP Protocol Remote access 4 Stream Main Stream Device address 10 2 47 49 34567 EEE st 00 o2 T te M LocalHost 00 44 22 55 66 22 10 2 7 134 LocalHost OO 10 00 07 7S 21 10 2 20 119 LocalHost o0 4d 22 22 44 22 10 24 16 LocalHost 00 710 00 02 17c b 3 10 2 29 49 LocalHost DO e D erl C i 10 272 17 119 ili Pic 4 45 the device list searched under remote channel setting Channel Status channel status is to show the status of all the digital channel When there is what existing status including Max Resolution This Resolution Connection Status For example The channel status for 4 2 mode is as below 70 NR SP AI erinrar aE ard ia V1 0 Eee ra x Channel Max resolution This Resolution Connection Status Connected lt Channel status E x Channel Max resolution This Resolution Connection Status Connected ma Chamnel status Channel Max resolution This Resolution Connection Status f 04x45 6 Connected 704x5765 Connected FO0Ax576 Connected WGA Connected Connected 928x576 Connected
17. is working normally Note 1 Make sure that the input voltage corresponds with the switch of the NVR power supply 2 Power supply demands 220V 10 50Hz Suggest using the UPS to protect the power supply under allowable conditions 15 NVR US Nada ia V1 0 3 2 Turn off There are two methods to turn off the NVR Entering main menu and choosing turn off in the turn off the system option is called soft switch Pressing the power supply switch is called hard switch Illumination 1 Auto resume after power failure If the NVR is shut down abnormally it can automatically backup video and resume previous working status after power failure 2 Replace the hard disk Before replacing the hard disk the power supply switch in the real panel must be turned off 3 Replace the battery Before replacing the battery the setting information must be saved and the power supply switch in the real panel must be turned off The NVR uses button battery The system time must be checked regularly If the time is not correct you must replace the battery we recommend replacing the battery every year and using the same battery type Note The setting information must be saved before replacing the battery otherwise information will lose 3 3 System Login When the NVR boots up the user must login and the system provides the corresponding functions with the user purview There are three user settings The names are admin guest and default and the
18. of selected remote device is not exist 6 Stream for remote channel was set by extra stream 7 User name amp password not matched 8 directly input with IP address or port No incorrectly when adding device 9 The resolution of added device is too large to display by the monitor 25 Click search why not search out any of the device Possible reasons are as followed 1 There is no other device exist in the Local area network 2 The subnet mask setting incorrectly on Network settings 26 The snapshot at alarm function was enable why not catch picture Possible reasons are as followed 1 HDD manage without partition for snapshot 2 Partition for snapshot is O 3 The snapshot function is not enable on record gt storage of related channel 27 The time shows on digital channel is not the same as local side Enable the time synchronous function of digital channel 28 Can not see preview picture of analog channel Possible reasons are as followed 1 The camera did not connect to video interface 2 The device did not connect to video source 3 Video source is broken 29 Picture will be frozen when multi connection and shift devices Picture come out from digital channel need few seconds shift device means to show new picture so it needs several seconds to buffer 92 ANVR USerManN ol cauece ac nmai ead cuducee ae cuna dams nccans ci V1 0 6 2 Maintenance 1 Please brush printed circuit boards connectors fans machine box and so on regu
19. or bad running circumstance for the NVR The hardware of the NVR is damaged System can not detect hard disk Possible reasons are as followed 1 2 The hard disk power supply line is not connected The cables of the hard disk are damaged The hard disk is damaged The SATA port of main board is damaged There are no video outputs in single channel multiple channels and all channels Possible reasons are as followed 1 2 3 4 5 The program is not matched Please update the program The image brightness is all 0 Please restore the default setup There is no video input signal or the signal is too weak The channel protection or the screen protection is set The hardware of the NVR is damaged Real time image problems such as the image color or the brightness distortion Possible reasons are as followed 1 When using the BNC output the option between the N mode or PAL mode is wrong and the image becomes black and white The NVR is not matched the monitor impedance The video transmission distance is too far or the loss of the video transmission line is too large The color and brightness setting of the NVR is wrong 87 NVR US Nada ci V1 0 6 state 10 can not find the video files in local playback mode Possible reasons are as followed 1 2 3 4 5 The data line of the hard disk is damaged The hard disk is damaged Update the different program with the ori
20. the listed files that accord with the searching criteria File information Look up the found file information 19 NR PS NA a V1 0 Playback control See detail in below chart Play Pause CS Backward play Slow forward US Fast forward l ee Picture 3 5 Playback control key Note play under frame by frame the playback status should be paused firstly Operation tips show function of the key that cursor placed Special functions AN Accurate playback Input time h m s in the time column and then click play button The system can operate accurate playback according to the searching time Local zoom When the system is in single window full screen playback mode you can drag your mouse in the screen to select a section and then left click mouse to realize local zoom You can right click mouse to exit Note When current resolution of the channel is over Max resolution to playback this channel will show a Red X 3 5 3 Record Control 113 3 iT 3 Please check current channel status o means it is not in recording status e means it is in recording status You can use desktop shortcut menu or click main menu gt recording function gt recording set to enter the recording control interface 20 NR USOT Ng a V1 0 Record Mode Record Mode All 2 A E TE Y S S 1 0 ON Ie E ic E A G Schedule DIODOS AAA SA Manual Sti Pp OK Cancel Picture 3 8 Record Mode
21. the photos to appointed address 54 NVR User Manual Main Menu gt System gt NetService gt EMAID Enable SMTP Server Your SMTP Server _ Port AAA Need ssL User Name Password Sender Recelver Title Picture 4 25 EMAIL SMTP server Email server address It could be an IP address or domain name Domain name can be translated only it is the correct DNS configuration Port Email server port number SSL Decide whether using Secure Socket Layer protocol to login User Name Apply the email server user name Password Input the password corresponding to the user Sender Set the email sender address Receiver Send the email to appointed receivers when the alarm is turned on You can set three receivers at most Title You can set as you wish IP Filter setup When choosing the white list only the listed IP address can connect the NVR The 64 IP addressed are supportive in the list When choosing the black list the listed IP address can not connect the NVR The 64 IP addressed are supportive in the list You can delete the set IP address by y in the options Note When the same IP address is in the white and black list at the same time the black list precedence 39 NR USE NA ia V1 0 is higher Main Menu gt System gt NetService gt IP FIL FER Enable O Restricted Type Blacklist A eee Picture 4 26 IP FILTER DDNS DDNS Type CN99 Enable a User Name Password Picture 4 27 DDNS s
22. this function Mobile Monitor Setup To visit the device by mobile please make a router mapping of this port and use CMS to monitor and operate it by protocol 59 NR USE Id iia V1 0 Main Menu gt System gt NetService gt Mobil x Enable Port 134599 Picture 4 32 Mobile Monitor Setup Enable Select it to make sure abnormal function workable Port It s a port of mobile monitoring which you need to make a router mapping of if want to visit it by mobile UPNP UPNP protocol is to realize auto port forwarding on router precondition of using this function is to make sure the UPNP function of router is enabled Main Menu gt System gt NetService gt UPNP x Enable Make sure UPNP is running on router befor using this Picture 4 33 UPNP Enable Choose Enable to make sure all UPNP settings available HTTP Route will automatically distribute HTTP port for the device when IE viewing it need this port TCP Router will automatically distribute TCP port for the device when monitoring via CMS it need this port Mobile Port Router will automatically distribute Mobile Port for the device when mobile monitor it need this port 60 NR USE dia V1 0 WIFI NVR connect to wireless router via WIFI module then to visit it through IP address the precondition of using this function is to make sure the NVR have connected with WIFI modern Authentication Signal OPEN Very Low Enable Password IP
23. 0 Appendix 3 Hard disk capability calculation Make sure the hard disk installed to the NVR for the first time Pay attention to the IDE hard disk lines connection 1 Hard disk capability There is no limit for recording machine We recommend 120G 250G size to keep better stability 2 Overall capability option The hard disk capability formula is Overall capability M channel number time hour capability in an hour M hour The recording time formula is Recording time hour overall capability M Capability in an hour M hour channel number The NVR introduces the H 264 compression technology lts dynamic range is very large so the hard disk capability calculation is based on the estimation values of each channel creating files in an hour Example For one piece 500G HDD real time CIF for recording it will keep recording for about 25 days HDD spaces per channel is 200M H if 4channels real time CIF at 24hours recording uninterrupted it can last 500G 200M H 24H 4ch 26 days 96 NVR WISER Maida iia V1 0 keep the card for guarantee uarantee to keepin repair Guarantee Item 1 1 year upon date of purchase we will guarantee to keep the goods in repair 15days upon date of purchase if there is function problem we should offer the same item subject to goods and packing maintain perfect 2 Guarantee service is subject to normally using 3 All of damages by man made tearing open the housing tearing off the stic
24. 280 1080P Channel Title Set Time Display Channel Title Record Status 1 Alarm Status Deflick Transparency 175 Resolution 11920 1080 Ki YGA Channel ic Ed Region Cover L Time Display Channel Title A Time Display Channel Title Record Status M Alarm Status Deflick Transparency fe 175 Resolution 1280 1024 VGA priority 7 62 NVR User Manual The GUI display page under full digital NVR channel Pic 4 36 output mode Channel Title Click the channel name modify button and enter the channel name menu Modify the channel name The 16 Chinese characters and 25 letters are supportive Time Display means the selective state Display the system data and time in the surveillance window Channel display means the selective state Display the system channel number in the surveillance window Record Status means the selective state Display the system recording status in the surveillance window Alarm Status means the selective state Display the system alarm status in the surveillance window Transparency Choose the background image transparency The range is 128 255 Resolution set display resolution Channel Choose the set code output channel number Region Cover means the selective state Click the cover area button and enter the corresponding channel window You can cover the arbitrary using mouse Black region is for output Time display and Channel display set the dis
25. ANVR USE NAL aa V1 0 Intelligent Mega pixel NVR User Manual PLEASE READ CAREFULLY AND SAVE This manual contains important information about this product s operation If you are installing this product for others you must leave this manual for a copy with the end user The NVR color included in the packing may be different from the user manual or packing The picture is only for reference NVR User Mal ana a e IO Please read before installing and using this product Damages caused by non compliance with this operating manual will void the warranty We will not assume any liability for damages to items or persons caused by improper handling or non compliance with the safety notices Any warranty claim will be null and void in such cases I Do not drop puncture or disassemble the camera or receiver otherwise the warranty will be voided 2 Avoid all contact with water and dry hands before using 3 Never tug on the power cords Use the plug to unplug it from the wall outlet 4 Do not expose the NVR to high temperature or leave it in direct sunlight Doing so may damage the NVR or cause NVR temporary malfunction 5 Use the devices with care Avoid pressing hard on the NVR body 6 For your own safety avoid using the NVR or power off the NVR when there is a storm or lightning 7 Remove the power adapter during long periods between usages 8 Use only the accessories and power adapters supplied by the manufacturer 9 To meet the
26. Address 192 168 Subnet Mask 24 a Gateway 192 Pic 4 34 WIFI configure Search click search to search all the available wireless device in current range enable tick it to enable firstly then go for further setting auto obtain IP address tick it to enable device will auto obtain a WIFI IP SSID wireless LAN name auto match to the wireless device u connected Password wireless network password of router IP address to set the IP address of device default is 192 168 1 12 subnet mask set subnet mask of device default is 255 255 255 0 gateway set gateway of device default is 192 168 1 1 RTSP To do surveillance via cross browser Safari Firefox Google chrome and VLC software This function only for monitor but can not control the device Enable M Port 554 Pic 4 35 RTSP setting 61 NR PS NA a V1 0 Enable m means enable tick it firstly before setting Port the default port is 554 4 4 5 GUI Display Configure the video output parameters including the front output mode and encode output mode Front output In the local preview mode include channel title time display channel display record status alarm status transparency and region cover Encode output In the network surveillance and video file mode include channel title time display channel display record status alarm status transparency and region cover Remark Part models support preview resolution 1920 1
27. Coverage Video Color Pic 4 54 restore to default TI NR USE iia V1 0 4 5 7 Upgrade a Main Menu gt Advanced gt Upgrade Upgrade Position u Pic 4 55 Upgrade Upgrade choose USB interface Upgrade file choose the upgrade file 4 5 8 Device Info Provide device interface info like audio in alarm in out to be conveniently used for user a Main Menu gt Advanced gt Device Info Audio in Channels 4 Alarm in Channels a Alarm Out Channels 1 GUI Theme General Remote control type General Maximum Playback large 4 Default playback large Enable RS237 M Enable PT Y Pic 4 56 device info 4 5 9 Import Export Users can export the log info and the configure file from device to connected flash stick and also can import related configure file from flash stick to settings which greatly bring convenience to the customers 78 NR USE Id Vo Ie mele File Name Set File Name File Name 4 57 Import Export interface 4 6 Info Display the hard disk information including HDD info code stream statistic log info version info 4 6 1 HDD info Display the hard disk state hard disk type overall capability residual capability the recording time and so on E Main Menu gt Info gt HDD Info Capacity Left Capacity Status Read Write 58 29 0 00 N Normal Read Write 21 69 0 00 MN Normal Read Write 79 99 69 83 Normal Read Write 79 99 79 99 Normal Read Write 79 99 79 99 Normal Read Wr
28. Delay 10 Sec Show Message O Send Email Q Buzzer O FTP upload O Video loss in full digital NVR mode Pic 4 9 Video loss Set method refer to chapter 4 3 1 Motion detect 4 3 4 Alarm input When the equipment obtains the external alarm signal the alarm function is turned on 43 NR PS Ng da V1 0 Alarm input is the same between hybrid mode amp full digital mode function enable when it was set normal only need to connect alarm sensor at alarm input port on local side the alarm information is occurring and will link to related setting functions at the same time Note Advanced button is the same as right click Alarm In Type Period AA interval 1 Sec Alarm Output Delay 10 Sec Record Channel MOB Ett Tour WABHKOOWSSIteiitatstsists PTZ Activation MNBA Delay 10 Sec Show Message O Send Email Q Buzzer a FTP upload O Alarm In 1a Type Period Interval 1 Sec Alarm Output 1 Delay 10 Sec Record Channel AN Z34 SEF Vs Tour ALAVA PTZ Activation Delay 10 Sec Show Message O Send Email O Buzzer O FTP upload O Alarm input in NVR mode Pic 4 10 Alarm input 44 NR USE NGOM dia V1 0 Set method refer to chapter 4 3 1 Motion detect 4 3 5 Alarm output Refer to chapter 3 5 4 4 3 6 Abnormal Analysing and inspecting current software and hardware of the device When some abnormal events happen the device will make a relative answer such as show message and buzzer a Main Menu gt Al
29. Menu gt Info gt Version Record Channel 8 Record Channel 8 Extra Channel 0 Extra Channel 0 Alarm In 8 Alarm In 8 Alarm Output 1 Alarm Output 1 System V4 00 R 10 00000002 1 System V4 00 R 10 00000002 1 Build Date 2012 10 26 09 00 26 Build Date 2012 10 26 09 00 26 MAC 260040620002 MAC 260040620002 SerialNo 28822101bdb62d13 SerialNo 28822101bdb62d13 Status 209 E Status 209 Nat status Probing DNS Nat status Connected Nat status code 0 Nat status code 2 202 130 112 247 Connect failed interface successfully connect interface Pic 5 1 cloud technology server connection status gt Log in cloud server Visit http xmeye net to see below log in page it devided into two mode by user and by device user can base on their need to log in freely Remark to log in by user the user need to register at the first time 82 NVR User Mal ana e IO myeys MMT Xs Y ZX OXY SOSA The firmmare released after Sep 28th 2012 the serial No had been updated from 12 bit to 16 bit Login And Preview Username Password verify 3616 PF Remenber Please Click Enter Guide if you visit first Register Download Web Get Password gt Log in by user Customer use their registered user name and password to log in will see below interface My Devices Device Manage User Info Logout Click My Devices to view config and playback It will download the component automatically to
30. Modify the existed user attribute Modify Group Modify the existed team attribute Modify Password Modify the user password You can set 1 6 bit password The blank ahead or behind the char string is invalid The middle blank in the char string is valid Note The user who possess the user control purview can modify his her own or other users password User Name Old New Confirm Pic 4 48 modify password Add user Add a user in the group and set the user purview Enter the menu interface and input the user name and password Choose the team and choose whether cover using the user Cover using means that the account can be used by multiple users at the same time Once choose the team the user purview is the subclass of the team 74 Ree User Ma Malaisia We recommend that the common user s purview is lower than the advanced user Main Menu gt Advanced gt Account gt Add User User Name eee Kcuseable a Password Sa Confirm GROUP ladmin SS EN AE Shutdown the device Channel Title schedule Backup HDD Management PTZ Control Pic 4 49 Add User Add Group Add a user group and set the purview There are 33 different purviews shut down the equipment real time surveillance playback record setting video backup and so on Main Menu gt Advanced gt Account gt Add Group Authority Channel Title Schedule Backup HDD Management PTZ Control Account Query System Info Query Log Info Clear Log
31. Step 2 click the Preset button then write the preset points in the input blank Step 3 click Settings button return the Picture 3 10 Complete setup that is the preset points and preset position corresponds Clear Preset Input preset points click Remove button remove the preset PTZ Config x Preset point input blank M Freset 1 Preset button Pattern Patrol No Border papeenenes RAID Del Preset Picture 3 11 Preset Settings 2 Preset Point Calls In Picture 3 10 click Page Shift button enter PTZ control interface as shown in Picture 3 12 In the input blank write the preset points then click Preset button PTZ turn to the corresponding preset point 23 NVR User Manual terre V1 0 A CoO a Value input blank PTZ Control AutoScan AutoPan Page Switch Picture 3 12 PTZ Control 2 Cruise between Points Multiple preset points connected cruise lines call cruise between points the PTZ run around on the line 1 Cruise Between Points Settings Cruise lines is connected by multiple preset points setting procedure is as follows Step1 In Picture 3 10 the Direction key will turn PTZ to designated location click Settings button to enter Picture 3 13 Step 2 click Cruise buttons the write proper value into the Cruise Line and Preset Points blank then click Add Preset Points button complete setting also can add and delete cruise line which has been set up Step 3 repeat step1 and step2 u
32. T2 E Alarm Output Alarm Output Output Adjust Output Adjust Logout Logout O View 1 View 4 O View 1 View 8 Ed View 4 E View 9 O View 3 View 16 View 9 Spot Shortcut menu in full analog NVR Hybrid HVR mode B Main Menu E Main Menu b Record Mode 9 Record Mode PlayBack a PTZ Control ia HighSpeedPTZ balite di ALE Pop E Alarm Output bl Oupu E Output Adjust Output Adjust Oe bs ns DView 1 DO View 1 B View 4 View 4 Spot Shortcut menu in full digital NVR mode Picture 3 2 Shortcut Menu compare to analog hybrid mode s shortcut menu the full digital mode do not have color setting function 3 5 1 Main menu When you login the system main menu is shown as below 18 NVR User Manual Es Main Menu Record Advanced Cancel Picture3 3 Main Menu 3 5 2 Playback There are two methods for you to play the video files in the hard disk 1 In the desktop shortcut menu 2 Main menu gt Record gt Playback Note The hard disk that saves the video files must be set as read write or read only state 4 5 1 0087601 A O 08 15 01 E O 09 20 01 H 0O 04 25 01 E Oo g 30 01 R M3 11 08 40 04 E O 08 47 50 E o cer 84 00 A O 00 56 21 A O 10 04 08 Fi O 10 05 01 1706 95 Ge a A 1708 23 04 55 00 f 7445 2 3 Picture 3 4 video playback 1 Playback control 2 Operation hint 3 file searching 4 listed files 5 file information Listed files Look up
33. TZ decoder and the NVR are not matched When multiple decoders are connected the far port of the PTZ decoder line A B must connect a 120 Q resistance to reduce the reflection otherwise the PTZ control is not stable The distance is too far The motion detect is not working Possible reasons are as followed 1 2 3 4 The time range set is not correct The motion detect area set is not correct The sensitivity is too low Limited by some hardware edition can not login via web or CMS Possible reasons are as followed 1 6 T The system is windows 98 or win me We recommend updating to windows 2000sp4 or higher Version or installing the software for low edition ActiveX is hold back The version is not exceeded dx8 1 Update the display card driver Network connection failure Network setting issues Invalid password or user name The CMS is not matched the NVR program version The image is not clear or there is no image in network preview state or video file playback state 89 NVR US Wail ol caueceac nme ceadcuduceeeaecuna dams iceans ci 15 16 17 18 Possible reasons are as followed 1 2 5 6 Network is not stable The user machine is resource limited Choose the play in team mode in the network setup of NVR The region shelter or channel protection is set The user has no surveillance purview The real time image of the hard disk recording machine itself is not
34. annel for single window display and cursor place for 27 NR USE Ia V1 0 multi window display You can use the desktop shortcut menu and enter the interface The image parameters include tonality brightness contrast saturation You can set different parameters at different time sections Color Setting 05 Period Brightness Contrast Saturation Hue Gain Horizon Sharpness Vertical Sharpness Picture 3 18 Color Setting 3 5 7 Output Adjust Hybrid mode is with black margin vertical amp horizontal while full digital mode without Adjust TV output area parameters You can use the desktop shortcut menu or enter main menu gt management tools gt Output adjust Top Deflate Top Deflate Bottom Deflate Bottom Deflate E Left Deflate Left Defiate B Right Deflate Right Deflate Qe Black vertical Black horizontal 50 Hybrid HVR Mode full digital NVR mode Picture 3 19 Output Adjust Note The black margin vertical 8 horizontal at output adjust of hybrid mode is only effect to analog channel 28 NR USE ia V1 0 3 5 8 Logout Logout shut down the system or reboot up You can use the desktop shortcut menu or enter main menu Logout AVA ZN Reboot Picture 3 20 Logout Shutdown Reboot the system logout Quit the menu Offer password next entrance shut down Quit the system Turn off the power supply When press the shut do
35. anoconnns 7 2 VOpernpackage CN si oda 7 A A O NSS 8 2o Snell INS ANAlON SS SS IS 9 Ze SION A AO 10 ZIRON ANS arabe RO RR 11 2 6 Audio and video input and output CONNECtIONS ccccccnnnnnooaaauuonnnononococononananananonononononononocononananannnnos 12 20 1 VIGEO INDUU CO MECcIN S A cin 12 2 6 2 Video output connections and OptiONS ccccccccnnnnnnnononananananononococonononananana nono nononononoccnononos 12 200 gt DIMASO INP AA AAA 13 A Vo e o AP AN 13 2 6 9 Audio signal OUIDU Eo nia 13 2 Alarm input and output conneclON Siusisrasriala alcala 13 2 Alar MIN PUE POCS peccal ON erai a dels 14 2 2 Alarm Output DOM Spec AAA AAA SA 14 2 3 Alarm output port relay parameters oocconooooooononcnononananananononononnnannnonocoonnonananancccconinnnns 15 210 SPCC COMMS COMME CHONG ratita 15 mrs Lo Ox OPE ON nee enn ee dai 15 Sl he peers en a OR 15 22 JU pio y APPO OP O O ae aaa eS ea ae ate eae 16 SS Sle MONI PP A Greater ea A once tess 16 A RO 17 DD AISSIKODy SOK CCUM TINS TU E 17 A A O Sacadastaceoseeehaaadatasd Ma eaaderena aishadaweas aes 18 ESTA AA ere ee AEA et oe ee ee ETA ee er eee en ee eee ee 19 Bo RECO CONTO a aa 20 SO ANO IDU aaa 21 9909 TZ COMMON A N aca esa a a Tee T 22 SSO al CUNO AA A TN 21 O A A A 28 A A T A 29 SS 6 Maen Rye CHET ORE ON 29 ATO AF e E EA ten earner ce E E E RO 30 Ae Man men NVI AMO iia 30 ALR A RT 33 A 2 2 Pay DA Korn Sich aie CeO SCAG SERS OE ene
36. arm gt Abnormality Event Type Mo Disk E Enable Show Message amp Buzzer Picture 4 11 Abnormal emer Disk Error Disk No Space Net Disconnection Event Type selecting abnormity you want to inspectilamiecelabilles Enable Select it to make sure abnormal function workable Show message Automatically alarm cue dialog box come out of the main screen Buzzer Device will have one long nosie di while alarm is happening 4 3 7 Intelligent analysis Note only part of product support this function at present To analyze the video image when system detect object that meet pre set algorithm rules and fit set flexibility and minimum image distance will trigger video analysis alarm and enable the linkage function 45 NR USE NA da V1 0 only the 1 channel of full analog mode and hybrid mode can support this function and if this function is enabled then video blind is invalid FMain Me nu gt Alarm gt Intelligent Analysis Channel 3 Enable Algor Perimeter Rule Period Ser Interval Alarm Output Delay Record Channel Tour PTZ Activation SRR Delay 10 show Message send Email Buzzer FTP upload Pic 4 12 Intelligent analysis setting page Channel No only shows by 1 at present only the 15t channel with maximum resolution of 1080P in the full analog NVR mode and hybrid HVR mode Enable tick it to enable the video analysis function then can go for further setting Perimet
37. at interference will not occur in a particular installation If this equipment does cause interference to radio or television equipment reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Move the equipment away from the receiver Plug the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio television technician for additional suggestions You are cautioned that any change or modifications to the equipment not expressly approved by the party responsible for compliance could void Your authority to operate such equipment Disposal If the devices system no longer functions or can no longer be repaired it must be disposed of according to the valid statutory regulations Disposal of spent batteries accumulators Y ou are required by law Battery Ordinance to return all spent batteries and accumulators Disposing of spent batteries accumulators with common household waste is prohibited Batteries accumulators that contain y hazardous substances are marked with the symbols on the side These symbols indicate that it is prohibited to dispose of these batteries accumulators in the household waste The abbreviations for the respective heavy metals are Cd cadmium Hg mercury Pb lead You can return spent bat
38. ay time Set main extra coding parameter code mode resolving ability frame rate code stream control image quality type code stream value frame between value video audio enable Note only Hybrid mode and full analog mode have encode configuration Set basic network parameters DHCP and DNS parameters network high speed download PPPOE NTP Email IP purview DDNS parameter set channel title preview hint icon state transparency cover area time title channel title fold Note only analog channel can set channel name region cover time title channel title fold Set channel PTZ protocol address baud rate date bit stop bit check Note Hybrid mode shows PTZ configuration Part models have no this function Set serial port function baud rate date bit stop bit check Note Full digital mode shows RS485 Device Set serial port function baud rate date bit stop bit check Note Part Models have no this function Set patrol mode and interval time 31 NVR User Mamando cana Set Spot tour mode and time interval Spot Note Part Models support Set channel mode check channel status and configure the digital Digital channel etc Note Part Models support Hard disk Set appointed hard disk as read write disc read only disc or redundant disc clear data resume date and so on management User Modify user team or password Add user or team Delete user or team management
39. button border O ee eT hell Tail Picture 3 15 Boundary Scan Setup 2 Boundary Scan Calls In Picture 3 10 click Page Shift button then enter PTZ control menu as shown in Picture 3 12 Please input the number of scan in the value blank then click Scan button PTZ begins to work on the scan line Click Stop button to stop 26 NR SP NA ia V1 0 5 Horizontal Rotating Click Horizontally Rotating button PTZ begins to rotate horizontally relative to the original position of the camera Click the Stop button to stop 6 Rotate Click on horizontal Rotating button PTZ turn around 7 Reset PTZ restart all the data clears to 0 8 Page Shift In Picture 3 12 click Page Shift button into Picture3 16 setting auxiliary function Auxiliary number corresponding to auxiliary switch on the decoder PTZ Control 05 Direct Aux Ope Light Open Close Aux Num O pe Picture 3 16 Auxiliary Function Control Intuitive Auxiliary Operation choose auxiliary equipment select Open or Close button switch control Auxiliary Number 1 The operation of corresponding auxiliary switch according to PTZ agreement Page Shift In Picture 3 16 click Page Shift button enter the Picture 3 17 PTZ Main Menu the menu itself can be control by the menu control buttons 3 5 6 Color setting color setting only apply for Hybrid HVR full analog NVR mode and only analog channel can setting Set the selective image parameters current ch
40. clear Network connection is not stable Possible reasons are as followed 1 2 3 4 Network is not stable IP address is conflicted MAC address is conflicted The net card of the NVR is bad There is something wrong with the USB backup or writing a CD Possible reasons are as followed 1 2 3 4 5 The rewritable machine and the hard disk are shared the same data lines The data is too much Please stop recording and backup The data exceeds the backup storage The backup equipment is not compatible The backup equipment is damaged The keyboard can not control the NVR Possible reasons are as followed 1 2 3 The serial port of the NVR is not set correctly The address is not correct When multiple transformers are connected the power supply is not large enough Please give each transformer individual power supply 4 The distance is too far Alarm can not be recessional Possible reasons are as followed 1 The setting of the alarm is not correct 90 NVR User Manual 2 The alarm output is turned on manually 3 The input machine is damaged or the connections are not correct 4 There are some problems for specific program edition Please update the program 19 Alarm is not working Possible reasons are as followed 1 The setting of the alarm is not correct 2 The connection of the alarm is not correct 3 The alarm input signal is not correct 4 Aalarm is connected wit
41. dress Remote acce 1 chConfigOl 10 6 10 9 2 A chConfigU2 10 6 5 54 Advanced Single link page of digital channel 68 NR USE di VAGO MAA E Channel Enable Time synchronization Connection mode Multi link Polling time 10 Sec Network Configuration list Confiqur name Device Type IP Address Remote acce Multi linkage page of Digital channel Pic 4 43 digital channel interface Channel select channel title Enable Open digital channel tick enable then can do related settings Time Synchronization Tick it means the time of this channel and device is the same Connection Mode can be singe connect or multi ink multi link modes can connect to several devices device will be tour displayed one by one tour interval can be set no less then 10s Delete If the user want to change device select the existing device click delete will be ok Add click add will come out below page to add new device Remote access configuration Configur name chConfigO1 Device Type Pc Protocol Remote access 1 Stream Main Stream Device address 10 6 5 54 Port e Username Foe Ed DeviceName MAC IP Address Port Pic 4 44 remote channel configure page 69 NV User Mana diia Configure Name device is with default configure title user can revise it if necessary Device Type 3 types IPC NVR HVR user can choose as what you like default is IPC Protocol Default is TCP Remote channel
42. e connecting the device please pay attention to follow situations 1 Alarm input A Alarm input is grounding alarm input B Alarm input demand is the grounding voltage signal C When the alarm is connected with two NVRs or connected with NVR and other equipments it should be isolated by relay 2 Alarm output Alarm output can not be connected with high power load no more than 1A When forming the output loop it must prevent the big current from relay damage Use the contact isolator when there is a high power load 3 PTZ decoder connections 13 NVR US Nada ci V1 0 A The grounding of the PTZ decoder and NVR must be shared otherwise the common mode voltage will lead to the PTZ control failure The shielded twisted pair is recommended B Avoid the entrance of high voltage Make the layout reasonably Take precaution from the thunder C In the outlying end connect 1200 resistance paralleled to reduce the inflection and insure the signal quality D The 485 AB lines of NVR can not connected with other 485 output equipments paralleled E The voltage between the AB lines of the decoder must be less than 5V 4 Front equipment grounding note Bad grounding can lead to the burnout of the chip 5 Alarm input type unlimited The NVR alarm output port is constant opening type 2 7 1 Alarm input port specification 4 8 channels alarm input Alarm input type unlimited The grounding and the com port of the alarm sensor are parallel The alarm sen
43. e temperature in the room lower then 35 C 95 2 Keep the equipment have 15cm 6 inches space around in order to air s circulation 3 From bottom to shelf installation 4 When multiple components install in the frame please take preventive measures to avoid power socket overload 2 4 Front panel 7 NR USE Ia V1 0 A 2 DIGITAL Kag Skybest DIGITAL VEDIO RECORDER i 38 Lof eee Lit 0 Uv ee Oe Oe v e gt ii gt e gt gt Direction keys include Up A Down F Left lt Right P In Direction menu mode use direction keys to move cursors of menu setting keys items In PTZ control status they can be used to control the direction of PTZ Confirming PONNE confirming key 0K Channel choice Pa retoma SSCS aa eon ail cml Play by single frame Controling mn CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 1 16 number key single keys channel choice I Remote Control IR remote control receiving Window 10 NR PS NA dia V1 0 2 5 Rear panel Yy MOMO a e ho BERS E o oS Note VIDEO OUT 2 After connect to this BNC interface no matter what operation in VGA the TV only output the device s preview screen no GUI interface 2 6 Audio and video input and output connections 2 6 1 Video input connections The video input port is BNC connector plug The demand of input signal is PAL NTSC BNC 1 0Vp p 75Q 11 ANVR US Nada ici V1 0 The video
44. emagnetizing regularly 3 Stay away from the electro magnetic Interference TV is not a credible replacement as a video output It demands reducing the use time and control the power supply and the interference introduced by the nearby equipments strictly The creepage of low quality TV can lead to the damage of other equipments 2 6 3 SDI video input Only part models support SDI encode for 1080P 12 ANVR US Nada ci V1 0 2 6 4 Audio signal input Audio port is BNC connection The input impedance is high so the tone arm must be active The audio signal line should be firm and away from the electro magnetic Interference and connected credible which avoid false and joint welding and oxidation The high voltage current should be avoided especially 2 6 5 Audio signal output Commonly the output parameter of NVR audio signal is greater than 200mv 1KQ BNC which can connect the low impedance earphone and active sound box or other audio output equipments through power amplifier If the sound box and the tone arm can not be isolated howling phenomena is often existed There are some methods to deal with the above phenomena 1 Adopt better directional tone arm 2 Adjust the sound box volume to be under the threshold that produces the howling phenomena 3 Use fitment materials that absorb the sound to reduce reflection of the sound 4 Adjust the layout of the sound box and the tone arm 2 7 Alarm input and output connections Befor
45. equipment can write or read data Read only Disk The equipment can read data but can not write data Redundant Disk Double backup the video files in the write read disk Main Menu gt Advanced gt HDD Manage HDD No Type Status Read Write zan A Read Write Normal 1 2 Read Write Normal 2 Read Write Normal M Read only 3 1 Read Write Normal E E 4 1 Read Write Normal i Red undant 5 Read Write Normal 6 1 Read Write Normal OS sE Read Write Normal Read Write Normal Recover Partition Cancel Pic 4 46 HDD manage 4 5 2 Account Manage the user purview Note 1 The character length is 8 bytes at most for the following user and user team name The blank ahead or behind the character string is invalid The middle blank in the character string is valid Legal characters include letter number underline subtraction sign dot 2 There is no limit in the user and user group You can add or delete the user group according to user definition The factory setup include user admin You can set the team as you wish The user can appoint the purview in the group 3 The user management include group user The group and user name can not be the same Each user only belongs to one group 73 NVR User Manual User Name Group 2 O admin admin O guest user Normal O default user Default Use Modify Password Modify Group Add User Pic 4 47 account management Modify User
46. er alert ltems care Algorithm rule at drop down boxMEGAUE DEEER to choose the algorithm rule of detection Rule choose different algorithm rules the related setting page is different Cordon gt Show traces tick it to enable when alarm triggers there will be red box around moving objects gt Sensitivity base on different requirement there are 3 options in the drop down box ashi gt Minimum image distance range between 0 30 the more flexible the less image distance gt Alert way there are 2 kinds cordon and warning area Cordon Can set 3 prohibited directions bidirectional prohibited from top to bottom from left to right from bottom to top from right to left when the setting cordon is too slope show with from left to right from right to left otherwise will be from top to bottom from bottom to top when the moving object meet preset cordon rules the alarm 46 NR USE a V1 0 will be triggered Warning area can set 3 kinds of prohibited directions bidirectional prohibited enter and leave when the moving object meet preset warning area rules alarm will be triggered gt Rules click setting enter rule setting page right click mouse choose add use mouse to fix two or more point and then connect them to form a line or a irregular region after that a box of prohibited direction options will come out choose one of them right click mouse click Yes return to previous page click Yes ala
47. etup It is the abbreviation of dynamic domain name server Local domain name Provide the domain name registered by DDNS User name Provide the account registered by DDNS Password Provide the password registered by DDNS When the DDNS is successfully configured and start you can connect the domain name in the IE address column to visit Note The DNS setup must be configured correctly in the network setup 56 NV User Manabi dida V1 0 FTP setup FTP is available only when alarm happens or alarm activates record and snapshot it will upload related record and snapshot pictures to FTP server Main Menu gt System gt NetService gt FTPO Enable 0 Se rver I P F T P Port User Name Password CJ Anonymous A Max File Length pe e M DirMame Picture 4 28 FTP setup Enable Click Enable then all settings will be available Server IP IP address for FTP server Port Domain Port of FTP default 21 User Name User name of FTP Password Password of user Anonymous enable anonymous no need setting user name and password Max File Length Max length for upload files at every packed default 128M Dir Name The directory of upload file Note The user should be with authority to upload files ARSP Startup DDNS server to add devices and manage it in the DDNS server 5 NVR User Manual Type DNS Enable a Server IP 192 168 1 112 Port 15000 User Name test Password TITTI Update Period 1
48. gin program files The video files to look up are covered The recording is not on The local video is not clear Possible reasons are as followed 1 2 3 4 5 The image quality is too bad The reading program is wrong Reboot up the NVR The data line of the hard disk is damaged The hard disk is damaged The hardware of the NVR is damaged There is no audio signal in the surveillance window Possible reasons are as followed 1 2 3 4 It is not an active tone arm It is not an active sound box The audio lines are damaged The hardware of the NVR is damaged There is audio signal in the surveillance window but mo audio signal in the playback Possible reasons are as followed 1 2 Setting issues the audio option is not chosen The according channel is not connected with the video The time is wrong Possible reasons are as followed 1 2 3 Setting is wrong The battery is in bad connection or the voltage is too low The oscillation is damaged 88 NVR US Nada ci V1 0 11 12 13 14 The NVR can not control the PTZ Possible reasons are as followed 1 2 8 There is something wrong with the frontal PTZ The setting connection or the installation of the PTZ decoder is not correct The connections are not correct The PTZ setting of the NVR is not correct The protocols of the PTZ decoder and the NVR are not matched The address of the P
49. h two loops synchronously 20 The remote controller is not working Possible reasons are as followed 1 The remote control address is not correct 2 The remote control distance is too far or the angle is too large 3 The battery is used up 4 The remote controller or the front panel of the recording machine is damaged 21 The storage time is not enough Possible reasons are as followed 1 Front vidicon quality is bad The lens is too dirty The vidicon is in backlighting installation 2 The hard disk capability is not enough 3 The hard disk is damaged 22 The downloading files can not play Possible reasons are as followed 1 There is no media player 2 There is no DX8 1 software or higher edition 3 There is no DivX503Bundle exe file to play AVI video files The DivX503Bundle exe and ffdshow 2004 1012 exe files must be installed in the windows xp system 23 can not remember the advanced password or network code in the local menu operation Please contact the local service or call the HQ service We will offer the service according the machine type and the program edition 91 ANVR US Wail ol caueceac nme ceadcuduceeeaecuna dams iceans ci V1 0 24 Can not see the preview picture the digital channel Possible reasons are as followed 1 Did not add device 2 The device of related channel was not enable 3 The device of related channel was not selected 4 The selected device did not connect to video sources 5 The channel title
50. ice number the default device number is 255 can be in the management tools gt system parameters modification equipment number can be set to a maximum of 255 in the remote control to enter the setting of the 3 digit number no 3 front patch 0 click on the remote ENTER key The code immediately after the completion of operation according to the remote control on the function of hard disk video recorder operation Remote check exception 94 NVR US Man ol cauace ccna ead cuduceee ne ci V1 0 Check the battery positive and negative polarity Check the battery has run out Check remote sensor is shielded Whether near fluorescent lamps in use Appendix 2 Mouse operation The mouse in USB connection is supported Take right hand as an example Double click one item in the file list to playback the video Double click the playback video to zoom in or out the screen Double left click Double click the channel to make it full screen display double click again to resume the multi window display Left click Choose the according function in the menu Pop desktop shortcut menu in preview state Right click Current shortcut menu in the menu Add or subtract number in the number setting Press middle button Switch the items in the combo box Page up or down in the list Choose the widget or move the item in the widget Set the motion detect area Drag mouse Set the cover area 95 INVES USEF VIAN All nc ainia V1
51. ing to record type regular detect and alarm and period Manual No matter what the present channel is in a state once choose manual button it will have snapshot at related channels Stop No matter what the present channel is in a state once choose stop button it will stop snapshot at related channels Period Set normal record period it only startup Snapshot Storage at set period Type Three types regular detect and alarm Regular snapshot at set period Detect snapshot at set period when motion detect video blind and video loss which are preset for snapshot enable Alarm snapshotatsetperiod when alarm in which is preset for snapshot enable Note for related alarm function please refer to chapter 4 3 4 3 Alarm Function Alarm functions include motion detect video blind video loss alarm input and alarm output abnormality intelligent analysis 4 3 1 Motion Detect When system detects the motion signal that reaches the set sensitivity the motion detect alarm is on and the linkage function is turned on Note Advanced button is the same as right click Motion detect function is different between Hybrid mode amp Full digital mode Digital channel not only to enable motion detect function at local side but also to enable the remote device that was connected when remote device detect motion movement local side will start alarm recording otherwise this function is not enable Hybrid mode only need to enable mot
52. ion detect function at local side 37 NR USE Id ia V1 0 Channel sensitivity Period Sere Interval fee Alarm Output 11 Delay OE Record Channel SIE Tour ga en a PTZ Activation 10 Sec Show Message O send Email 5 Buzzer E FTP upload O Channel 1 T7 Enable Period A interval 1 ESI Alarm Output 1 Delay 10 Sec Record Channel A234 SF 8 sliia Tour dada auaaar PTZ Activation Delay 10 Sec Show Message O Send Email O Buzzer O FTP upload O Video detect in full digital NVR mode Pic 4 4 Channel Choose the set motion detect channel Enable m means that the motion detect function is on 38 NVR User Manual Note Only the motion detect under hybrid mode full analog mode have this function of setting sensitivity and also only the analog channel can set region Region 1 Click set to enter the set area The area is divided into PAL22X18 Red block means the motion detect defensive area White block means the unfenced area You can set the area as followed Drag the mouse and draw the area Default all selected blocks are detection area Note Only the motion detect under hybrid mode full analog mode have this function of setting region and also only the analog channel can set region Picture 4 5 Region Period 1 Trigger the motion detect signal in the set time section You can set according to week or set uniformly Each day is divided into four time sections m means the set va
53. ite 79 99 79 99 Normal Read Write 79 99 79 99 Normal Read Write 79 99 G 79 99 G Normal Read Write 79 99 79 99 Mormal Pic 4 58 HDD info 79 NR SP NA ia V1 0 Tips o means that the hard disk is normal X means that the hard disk is broken down means that there is no hard disk If the user need to change the damaged hard disk you must shut down the NVR and take up all the damaged hard disks then install a new one behind serial number means the current working disk such as 1 If the corresponding disk is damaged the information will show 4 6 2 BPS Display the code stream Kb S and hard disk capability WMB H in real time It displays as the wave sketch map ai Main Menu gt Info gt BPS Channel Kb s Kb S MB H 1054 9 1043 440 1054 4 i 1043 440 1054 442 1 1043 440 1043 Es 1043 440 1043 E 1043 440 1043 1043 440 1043 5 1043 440 1043 6 1043 440 Pic 4 59 BPS 4 6 3 LOG To search log information base on the set search mode Log information include system operation configuration operation data management alarm affair recording operation user management file management and so on Set the time section to look up and click the look up button The log information will display as a list one page is 128 items Press Page up or Page down button to look up and press delete button to clear all the log information 80 NR USET IMM VIO Main Menu gt Info gt LOG Type Start Time 2010 08
54. ker un normally using or losing this card will not be guarantee User File iste Telephone Purchasing Address Retail price User signature Dealer signature Commodity aces Model No and specification 97
55. larly 2 Please keep the grounding well done to prevent the video or audio signal interfered and the NVR from static or inductive electricity 3 Do nat pull out the video signal line or RS 232 port or RS 485 port with the power on 4 Do not use the TV in the local video output port VOUT of NVR It will damage the video output circuit easily 5 Do not turn off the switch directly Please use the turn off function in the menu or press the turn off button in the panel 3 seconds or longer to protect the hard disk 6 Please keep the NVR away from heat resource 7 Please keep the NVR ventilated for better heat radiator Please check the system and maintain regularly 93 NVR User Manual Appendix 1 Remote controller operation 1 Power on off 2 3 Number key 1 O 7 10 Direction Oo A 1 E ek NOR WO 17 Volume 18 No function 19 PTZ 20 Press DEV key and press number key to input the same 16 Play PP N N O device No as the NVR Press enter key to operate the device 21 clear Note the same place have multiple devices remote control first according to the device number to select a piece of equipment it should give each device defines a unique device number or remote operation may be at the same time with the same number of multiple devices concurrently Remote control code operation In the remote controller press DEV button then enter the operating disk recorder dev
56. lid Set saturday bi Y 00 00 24 00 00 00 24 00 00 00 24 00 00 00 24 00 C 2 5 I 15 116 27 24 oun l Mon I Tue Wed Thu Fr gt d t Picture 4 6 set the time section 39 IN WIR SOP Malal id V1 0 Interval Only one alarm signal is turned on even there are several motion detect signals in the set interval Alarm output Start the external equipment of corresponding linkage alarm when the motion detect alarm is turned on Delay Delay a few moments and stop when the alarm state is turned off The range is 10 300 seconds Record channel Choose the recording channel multiple option supportive Trigger the video signal when the alarm is turned on Note Set in the recording setup and perform the linkage recording Start detecting video files in the corresponding time section Tour m means that the selective channel is single window alternate patrol preview The interval is set in the Main Menu gt System gt Tour PTZ Activation Set the PTZ activation when the alarm is turned on Hybrid mode PTZ link to the related PTZ information of analog channel While digital channel model the PTZ is link to the related PTZ information on the remote device connected Note to link PTZ need go Shortcut menu gt PTZ control to set preset point cruise between points 4 interval time etc PTZ Activation CAM 1 None CAM 2 None CAM 3 None CAM 4 None Picture 4 7 PTZ Activa
57. n package check When you receive the NVR please check first First please check whether there is any visible damage to the package appearance he protective materials used for the package of the NVR can protect most accidental clashes during transportation Then please open the box and get rid off the plastic protective materials Check whether there is any visible damage to the NVR appearance At last please open the machine crust and check the data wire in the front panel power wire the connection between the fan power and the main board 1 Front panel and rear panel NR USE da V1 0 The key function specification in the front panel and the interface specification in the real panel are in the specification For the same settings in menu it can be done quickly by copying 2 Check After open the cover you should check if it has obvious damage trace also please check the front panel data cable power cord and motherboard s connection are loose or not 2 2 Hard disk installation For the first use please install the hard disk this machine box can install two hard disk no limited capacity o UE i disassemble the cover connect the data wire connect the power wire cover the machine 8 fix the cover NR USOT NA a V1 0 2 3 Shelf installation This product chassis specification for the standard 1u so it can be installed in the standard shelf Installation steps and attention items 1 Make sure th
58. nable Day of Week Date Start Jan i ist Mon 7 07 01 End Yan 7 ist Mon 01 01 Picture 4 18 DST week DST Enable Day of Week Date start 2001 01 01 01 01 End 12 2001 01 01 01 01 Picture 4 19 DST date 50 NR SP NA dia V1 0 4 4 2 Encode setup some model under Hybrid mode full analog mode it has encode setup function encode settings is for analog channel only Set the video audio code parameter video file remote monitoring and so on Set every main stream parameter in the left part and set the extra stream parameter in the right part Note extra stream introduces video compression technique which was applying for multi channel playback simultaneously Dial up multi channel real time monitor under poor bandwidth or mobile monitor and so on 7 Ed Main Menu gt System gt Encode a Channel 1 i i Z Compression H 264 Extra Streaml M el Resolution crr 352 x288 OCIF 176x144 ss Bl Frame Rate FPS 25 W BR Quality Good General Bit Rate Kb S ER y A Bit Rate Type VBR I Frame Interval 2 Video Audio m L J Picture 4 20 Encode setup Independent channel code setting Channel Choose the channel number Compression Standard H 264 main profile Resolution Resolution type 1080P 720P 960H D1 HD1 CIF QCIF Frame Rate P 1 frame s 25 frame s N 1 frame s 30 frame s
59. ng function gt recording setup to set Note There is at least one read write hard disk refer to chapter 4 5 1 ee Main Menu gt Record gt Record Conf ig Channel I T Redundancy Length 60 min PreRecord 5 Record Mode Schedule Manual Stop week Thu x Regular Detect Alarm Period 1 00 A al E E Period 2 OO Period 3 DO Period 00 Picture 4 1 Record Configuration Channel Choose the corresponding channel number to set the channel Choose the all option to set the entire channels Redundancy Choose the redundancy function option to implement the file double backup function Double backup is writing the video files in two hard disks When you do the double backup make sure that there are two hard disks installed One is read write disk and the other is redundant disk refer to 4 5 1 Length Set the time length of each video file 60minutes is default value Pre Record Record 1 30 seconds before the action time length is decided by the code stream 33 NVR US Nada ci V1 0 Record mode Set video state schedule manual or stop Schedule Record according to the set video type common detection and alarm and time section Manual Click the button and the according channel is recording no matter the channel in any state Stop Click the stop button and the according channel stops recording no matter the channel in any state Period Set the time section of common recording The recording will start onl
60. ntil set out all the preset designated cruise lines Remove Preset Please input preset value in the blank click Remove Preset button then remove the preset points Remove Cruise Line Input the number of cruise line click Remove Cruise Lines button then remove the cruise lines set 24 NR USE NA iia V1 0 PTZ Config x Preset Points Blank Function Preset 0 me CS Border Add Preset Del Preset em Cruise Line Blank Del Tour Picture 3 13 Cruise Between Points Settings 2 The Calls of Cruise between Points In Picture 3 10 click Page Shift button enter PTZ control menu as shown in Picture 3 12 Please input the number of cruise in the value blank then click Cruise between Points button PTZ begins to work on the cruise line Click Stop button to stop cruise 3 Scan PTZ also can work on the preset scan line repeatedly 1 Scan setup Setting steps Step1 In Picture 3 10 click Setup button enter Picture 3 14 Step2 Click Scan button the input proper value in the scan value blank Step3 Click Start button enter Picture3 10 here you can set the following items Zoom Focus Aperture Direction and so on Click Setup button to go back Picture 3 14 Step4 Click End button to complete setup Click the right button of the mouse to exit PTZ Config A A A A Scan value blank Fu cti on Pattern Preset interval Scan Button Tour T SENOS Patrol No Border CTA Picture 3 14 Scan Setup 25
61. o radiate heat reduce power and extend the life span Special storage format which insures the data safety Compression real time compression by individual hard disk which insures the audio and video signal stable synchronization Backup through SATA interface and USB interface such as USB equipment removable hard disk and so on through net download the files in the hard disk Playback NVR User Manual sressssereseesersnessesesseesseesssesssnssansnnsnnesnsensennsaneeesseesseeesseesnenesseessneesseesseeessnseneeeeeree V1 0 individual real time video recording as well as searching playback network surveillance recording check downloading and so on multi playback mode zoom at arbitrary region Net operating through net tele surveillance in the real time tele PTZ control tele recording check and real time playback Alarm linkage Alarm activated video record tour message buzzer e mail ftp Communication interface RS485 interface which fulfills the alarm input and PTZ control RS232 interface which can extend keyboard connection to realize master as well as with computer serial port connection for system maintenance and upgrade and matrix control and so on Standard ethernet network interface which fulfills the telecommuting function Intelligent operating mouse action function fast copy and paste operating for the same setting 2 Open package check and cable connections 2 1 Ope
62. ol boundary scan assistant switch light switch level rotation and so on Note1 Decoder A B line connects with NVR A B line The connection is right 2 Click main menu gt system configuration gt PTZ setup to set the PTZ parameters 3 The PTZ functions are decided by the PTZ protocols PTZ Control 05 Speed a foom Focus Picture 3 10 PTZ setup Speed Set the PTZ rotation range Default range 1 8 Zoom Click button to adjust the zoom multiple of the camera Focus Click button to adjust the focus of the camera iris Click button to adjust the iris of the camera Hide Current interface will be temporarily hidden after click it Direction control Control the PTZ rotation 8 directions control is supportive 4 directions in Front panel is supportive High speed PTZ Full screen show channel image Left press mouse and control PTZ to rotate orientation Left press mouse and then rotate the mouse to adjust the zoom multiple of the camera 22 NR PS NA ia V1 0 Set Enter the function operation menu Page switch Switch between different pages Special functions 1 Preset Set a location for the preset calls the preset points PTZ automatically turns to the setting position 1 Preset option Set a location for the preset procedure is as follows Step1 in Picture 3 10 click the Direction button will turn into preset position click the Settings button to enter Picture 3 11
63. onononnnccconocononananananons 94 Appendix 2 Mouse Opera a 95 Appendix 3 Hard disk Capability calculatiOn ccooooooonooonnnconononanananoconnnnnnnnnnnncconnnnnnnnnnonccnnnnnnn ccoo 96 A E E 97 ANVR USE NAL ceo V1 0 1 Production Introduction 1 1 Product overview The series NVR is designed specially for security and defence field which is an outstanding digital surveillance product It introduces embedded LINUX operating system which is more stable It introduces standard H 264mp video compressed format and G 711A audio compressed format which insures the high quality image low error coding ratio and single frame playing It introduces TCP IP network technology which achieves the strong network communication ability and telecommunication ability The series NVR can be used individually or online applied as a part of a safety surveillance network With the professional network video surveillance software it achieves the strong network communication ability and telecommunication ability The series NVR can be applied in the bank telecom electric power system judicial system transportation intelligent housing factory storehouse water conservancy and so on 1 2 Main functions Real time surveillance spot interface video out 2 analog interface VGA interface and HDMI interface surveillance function through monitor or display Storage non working hard disk dormancy processing which is convenient t
64. our system will auto shift to six view after alarm finished Remark at preview mode click upper right icon can turn on off tour mean turn on mean turn off 4 4 9 Spot configure Remark Part models product can support this function To set TV tour display with sport port means enable mode tour you can choose single view four view nine view for single mode tour or hybrid mode tour When tour enables no matter what u operate on VGA side there is only the spot tour image output on TV side no GUI displayed 66 NVR User Manual TV channel Enable Tour Interval 5E Pe View 00100580800 De Eee View 4 AE View 16 1 Pic 4 41 Spot configure interval Set the patrol switch interval The set range is 5 120 seconds 4 5 0 Channel manage Remark Part models support this function Digital manage including digital channel channel status and channel mode Remark there is only set channel mode Channel manage page under all analog NVR mode 67 NR USE NGOM a V1 0 Main Menu gt System gt DigitalManager eL w ima Channel status Channel Type set the number of channel parameters Channel manage page under Hybrid HVR mode full digital NVR mode Pic 4 42 channel manage interface Digital channel Digital channels gt Channel Enable Time synchronization Connection mode Single conne gt Metwork Configuration list Configur name Device Type IP Ad
65. play position of channel title and time title the channel no region cover time title and channel title setting function exist at output mode only when the device is under hybrid HVR mode or full analog NVR mode 4 4 6 PTZ device RS485 device when under hybrid mode full digital mode it shows with PTZ device and D device Main Menu gt System gt PT2 Config PTZ Device RS485 Device Channel 4 Protocol PELCOD MONE Address 4 1 Baudrate 9600 S600 Data Bits 3 a Stop Bits 1 1 Parity 63 NR USE NA EI da V1 0 Pic 4 37 PTZ configure Channel Choose the dome camera input channel Protocol Choose the corresponding dome protocol PELCOD as an example Address Set as the corresponding dome address Default 1 Note The address must be consistent with the dome address Baudrate JChoose the corresponding dome baud rate length You can control the PTZ and vidicion Default 115200 Data bits Include 5 8 options Default 8 Stop bits Include 2 options Default 1 Parity 1 Include odd check even check sign check blank check Default void When under full digital mode it will show RS485 device Main Menu gt System gt RS485 Device Protocol NONE z Address Baudrate 600 Data Bits 2 Stop Bits 4 Parity None 4 38 RS485 device Protocol choose related protocol of brand model for example DaHua Address set with corresponding address default is 1 Baud rate choo
66. ptions in the drop down box 2 44 gt Detection type there are 8 kinds of detection type Brightness anomaly detection Sharpness detection Noise detection Color cast detection Screen freezes detection Scene change detection Anthropogenic interference and PTZ runway detection Can choose one or more types if necessary when video detect selected type the alarm will be triggered sensitivity High Brightness anomaly detection Sharpness detection Noise detection Color cast detection Screen freezes detection Scene change detection Anthropogenic interference detection PTZ runaway detection Pic 4 15 rule setting page of video diagnosis The setting way of set withdraw garrison time period and linkage parameter please refer to chapter 4 3 1 motion detection For example enable video analysis function algorithm rules is PEA the alert way in the rule is 48 NR USE NA ia V1 0 Cordon prohibited direction is bidirectional when a moving object across this warning line alarm is triggered see below pic4 16 Pic 4 16 the alarm image regarding one of the video analysis Video Teaching http v youku com v_show id_XNDY5Mjc0O Tcy html cordon http v youku com v_show id XNDY5SMijc3MjAw html Warning area http v youku com v_show id_ _xXNDY5Mjc40Dg4 html items stranded http v youku com v_show id XNDY5Mjc4MDAO html items stolen shift 4 4 System setup Set the system parameters such as General Encode
67. regulations pertaining to parental responsibility keep the devices out of the reach of infants 10 Check power cables do not get crushed or damaged by sharp edges whenever the devices are in operation Products with CE Marking comply with EMC Directive 2004 108 EC Low Voltage FCC Compliance Statement This device aber mit TE 1999 5 EC lt yo n EEC a e ik pation complies with Part 15 of the FCC Rules Directive 3 ih 5 RET TEL SEL g e es ae a issued by the Commission of the European P Operation is subjected to the following two gt de AN A er S z ia i Community Compliance with these directives 1 3 conditions 1 this device may not cause harmful kenaa e interference and 2 this device must accept any pe isana ais arenan Fiais interference received including interference that EMC EN 301 489 PP f y gt gt n si 5 gt tio aa 7 may cause undesired operation LVD EN 60065 Radio EN 300 328 FCC CE WARNING This equipment has been tested and found to comply with limits for a Class B digital device pursuant to Pan 15 of the FCC rules and ETSI EN 300328 These limits are designed to provide reasonable protection against harmful inter ference in residential installations This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee th
68. rm rules setting is finished show Traces Sensitivity High Minimum image distance Cordon Warning Area Rule SA Pic 4 13 rules setting cordon Items care gt Show traces tick it to enable when this function is triggered there will be read box shows around the moving object gt Sensitivity base on different requirement there are 3 options in the drop down box Hsia Minimum image distance range between 0 30 the more flexible the less image distance gt Alert way three modes Items stranded Items stolen Illegal parking Items stranded object appears within warning area and the size of object meet the rules of minimum image distance alarm will be triggered Items stolen object disappears within warning area and the size of object meet the rules of minimum image distance alarm will be triggered Illegal parking this way is similar with Items stranded gt Rules click setting enter the setting page of rule right click mouse choose add use mouse to fix 47 NR PS NA a V1 0 several points and then connect them to form a irregular region right click mouse click Yes return to previous page click Yes alarm rule setting if finished Show Traces Sensitivity High Minimum image distance gt QI WO O items stranded O Items stolen shift O Illegal parking Rule Pic 4 14 rule setting items care Video diagnosis gt Sensitivity base on different requirement there are 3 o
69. se bard rate that related device use default is 115200 Data bits including 5 8 options default is 8 Stop bits including 2 options default is 1 Parity Include odd check even check sign check blank check Default void Remark when analog channel existing there will be PTZ and RS485 at PTZ setting if device is all digital NVR mode it will show RS485 only 64 NR PS Ng ia V1 0 4 4 7 RS232 Part models do NOT support this function amp Main Menu gt System gt RS232 Function Console Baudrate 115200 Data Bits g Stop Bits Parity None Pic 4 39 serial port setting Serial Port Function Common serial port is used to debug and update program or set up specific serial port Baud rate Choose the corresponding baud rate length Data bits Include 5 8 options Stop bits Include 2 options Parity 1 Include odd even mark space default is none 4 4 8 Tour Set the patrol display PY means that the tour mode is enable You can choose the single view four view six view of single mode tour or hybrid mode tour 65 NR USE NA dia V1 0 8 Main Menu gt System gt our Enable Tour ae Interval 5 View 1 View 4 Interval 5 Return after finished B Pic 4 40 tour configure interval Set the patrol switch interval The set range is 5 120 seconds alarm tour set the interval to shift alarm tour range is 5 120 seconds choose return when alarm ends when alarm link to t
70. se names have no password Admin is the super user purview guest and default s permissions are preview and video playback User admin and guest s password can be revised while their permissions can t be revised user default is the default login user whose permission can be revised but not its password 16 SYSTEM LOGIN User Name ladmin Password Please Login Picture 3 1 System Login Password protection If the password is continuous wrong three times the alarm will start If the password is continuous wrong five times the account will be locked Through reboot or after half an hour the account will be unlocked automatically For your system security please modify your password after first login 3 4 Preview You can right click mouse to choose the switch between the windows The system date time and channel name are shown in each viewing window The surveillance video and the alarm status are shown in each window Table 3 1 Preview icon 3 5 Desktop shortcut menu In preview mode you can right click mouse to get a desktop shortcut menu as the picture 3 2 shows The menu includes main menu record mode playback PTZ control High Speed PTZ Alarm Output color Setting Output adjust Logout view mode shift spot Some model support Spot 17 NR USE NA dia V1 0 El Main Menu amp Main Menu 5 Record Mode Record Mode q PlayBack PlayBack PTZ Control T Ae Sahn HighSpeedPTZ HighSpeedP
71. sfying the set file attributes 35 NR USE NA EI ia V1 0 Backup format configurate the backup file format according to require can choose Start pause Click the play button to start the backup and click the pause button to stop the backup Note During backup you can exit the page layout to carry out other functions Burning the file will be burned synchronously after click it Erase Choose the file to delete and click erasure to delete the file Stop Stop the backup 4 2 4 Snapshot Storage Note part products have this function Setup snapshot parameters for different channels At first time it s set for 24hours snapshot continuously please go to Main Menu Record Snapshot Storage for appropriate setting Note lf normal snapshot storage please setup snap at Main Mend advanced snapshot please refer to chapter 4 5 1 HDD Manager Main Menu gt Record gt SnapShot Conf ieee Channel 1 bd PreSnap 2 Pictures Mode schedule Manual Stop Week Fri Regular Detect Alarm Period 1 00 00 24 00 Period 2 00 00 24 00 E O O Period 3 00 00 24 00 L O O Period 4 00 00 24 00 a E C KERET O EET Picture 4 2 snapshot storage Channel Select the related channel to set click all to set all channels Presnap Setup presnap picture quantity before recording default is 5 pieces Record Set record status Schedule Manual and Stop 36 ANVR US Nada ci V1 0 Schedule Realise snapshot accord
72. signal must be accorded with the state standard which has the high signal to noise ratio low aberration and low interference The image must be clear and has natural color in the appropriate brightness Insure the vidicon signal stable and credible The vidicon should be installed in the appropriate location where is away from backlighting and low illumination or adopts the better backlighting and low illumination compensation The ground and power supply of the vidicon and the NVR should be shared and stable Insure the transmission line stable and credible The video transmission line should adopt high quality coaxial pair which is chosen by the transmission distance If the transmission distance is too far it should adopt shielded twisted pair video compensation equipment and transmit by fiber to insure the signal quality The video signal line should be away from the electro magnetic Interference and other equipments signal lines The high voltage current should be avoided especially Insure the connection stable and credible The signal and shield lines should be firm and connected credible which avoid false and joint welding and oxidation 2 6 2 Video output connections and options The video output is divided into PAL NTSC BNC 1 0Vp p 75Q and VGA output When replace the monitor by the computer display there are some issues to notice 1 Do not stay in the turn on state for a long time 2 Keep the computer display normal working by d
73. sor is external power supply The grounding of the alarm and the NVR should be shared The NC port of the alarm sensor must be connected with the NVR alarm input port The grounding of the power supply and the alarm sensor must be shared when used in external power supply 2 7 2 Alarm output port specification 1 channels alarm output There is external power supply when using the external alarm equipment Please refer to the relay relevant parameters to avoid the overload that damages main machine 2 7 3 Alarm output port relay parameters Interface material silver rating Rating switch capacity 30VDC 2A 125VAC 1A resistance load maximal switch power 125VA 160W 14 NVR WISE Manacor V1 0 solation Turn on time longevity 2 8 Speed dome connections 1 Connect the 485 lines of the speed dome with the NVR 485 interface 2 Connect the video line with the NVR video input 3 Electrify the speed dome 3 Basic operation Note The button in gray display indicates nonsupport 3 1 Turn on Plug the power supply and turn on the power supply switch Power supply indicator light shining indicates turning on the video recorder After the startup you will hear a beep The default setting of video output is multiple window output mode If the startup time is within the video setting time the timing video recording function will start up automatically Then the video indicator light of corresponding channel is shining and the NVR
74. teries and accumulators that can no longer be charged to the designated collection points in your community outlets or wherever batteries or accumulators are sold Following these instructions will allow you to fulfill the legal requirements and contribute to the protection of our environment NVR US Ian oll canoe ec anai ead cuducee ae ci V1 0 User s installation and operation Manual Important Safeguards and Warding Do not place heavy objects on the NVR Do not let any solid or liquid fall into or infiltrate the NVR Please brush printed circuit boards connectors fans machine box and so on regularly Before the dust cleaning please switch off the power and unplug it Do not disassemble or repair the NVR by yourself Do not replace the components by yourself Environment Please place and use the NVR between 0 C and 40 C Avoid direct sunlight Stay away from heat source Do not install the NVR in the damp environment Do not use the NVR in smoky or dusty environment Avoid collision or strong fall Please insure the NVR level installation in a stable workplace Please install in ventilated place Keep the vent clean Use within the rating input and output scope NVR US Nada ici V1 0 Directory A POGUCTIONMINT OGUCUION zerrin eae 6 LA Product OV CG Wa 6 12 Man T UIC TONS 455 20occsicaS Seals aa lO A 6 2 Open package check and Cable CONNECtiONS ooooooccccnnonancconononananononanananononanannnoconanannncconanananoconanan
75. tion under hybrid mode Delay When alarm is over recording will last some seconds 10 300sec then stop Show message Pop the alarm information dialog box in the local host computer screen Send EMAIL m means sending an email to user when the alarm is turned on Note Set in the NetService and send email FTP upload to tick it the video amp picture of related record channel amp snapshot channel will be uploaded to assigned position 40 NR USE Ia V1 0 Note FTP upload need be set at Netservice Buzz When alarm happens device will come out with buzz 4 3 2 Video Blind When the video image is influenced by the environment such as bad brightness or reaching the set sensitivity parameter the camera mask function is turned on and the linkage function is turned on Same as motion detect function video blind is different between Hybrid mode amp Full digital mode Digital channel not only to enable video blind function at local side but also to enable the remote device that was connected when remote device with video blind local side will start alarm recording otherwise this function is not enable Hybrid mode only need to enable video loss function at local side Note Advanced button is the same as right click O Main Menu gt Alarm gt Video Blind Channel 1 Enable sensitivity Middle r Period er Alarm Output Delay Record Channel Tour PTZ Activation PB Delay Show Message send Email
76. wn button there is schedule hint After three seconds the system is shut down Cancel midway is of no effect reboot Quit the system Reboot up the system LZ AN Reboot T series logout 3 5 9 Window switch Preview in single window four windows eight windows nine windows sixteen windows according to your choice Note different video input number have different switchable preview picture 3 6 0 Spot Only some model support this function the second BNC interface regard as Spot interface the user 29 NVR US Ian oll canada cc nmai cad cuducee ae ii V1 0 can switch to Spot output image segmentation mode through shortcut menu After connect to this BNC interface no matter what operation in VGA the TV only output the device s preview screen no GUI interface Preview in single window four windows sixteen windows according to your choice Note Different video input number have different preview screen 4 Main menu 4 1 Main menu navigation Config Set the recording configuration recording type recording time section playback Set recording search recording play video file storage Record Set screen capture period type etc Storage Note Part Models have no this function backup Detect backup device format device back the selective files Set motion detect alarm channel sensitivity area linkage parameters Motion defending time section alarm output screen hint recording screen detection
77. y in the set range Record type Set recording type regular detection or alarm Regular Perform the regular recording in the set time section The video file type is R Detect Trigger the motion detect camera mask or video loss signal When above alarm is set as opening recording the detection recording state is on The video file type is M Alarm Trigger the external alarm signal in the set time section When above alarm is set as opening recording the detection recording state is on The video file type is A Note Refer to chapter 4 3 to set corresponding alarm function 4 2 2 Playback Refer to chapter 3 5 2 4 2 3 Backup You can backup the video files to external storage through setup Note The storage must be installed before the file backup If the backup is terminated the already backup can playback individually 34 NVR User Manual Ed sdb1 USB TET 528 06 MB 1 86 GB Picture 4 2 Backup Detect Detect the storage connected with the NVR such as hard disk or universal disk Backup 1 Click backup button and the dialog box is popped up You can choose the backup file according to the type channel and time _ Type Channel 2001 01 11 22 16 19 22 17 17 R 288 00 KB 2001 01 11 22 17 55 22 51 40 R 7 18 MB Required Remaining 8 22 MB 528 06 MB ie aa ser Y Picture 4 3 Backup Remove Clear the file information Add Show the file information sati
78. your computer Please wait a moment as it will take several minitues on your first visiting time Pic 5 3 cloud technology operation interface Device manage Mainly use to add device click add to add the serial number of device to be monitored 83 My Devices Device Manage User Info Logout SerialNo Device Name Username Operation Pic 5 4 device manage interface My Devices Device Manage User Info Logout Username admin default is admin Pic 5 5 add interface at device manage Remark in pic 5 5 the user name means the user name of monitored device password means the password of related user My Device Mainly show all the added device here click the on line device name can access to control this device accordingly 84 NVR User Mala ae O EHRE RAEM er2323 er23232134 skjloy 1212 NAT t s FE lt Ji arre Pic 5 6 monitor page log in by user Remark the icon of A means offline the device do not connect to server successfully gt Log in by device mysye MAT 1 The firmare released after Sep 28th 2012 the serial No had been updated from 12 bit to 16 bit Login And Preview verify 8447 Please Click Enter Guide if you visit first Register Download Web Get Password Pic 5 7 interface of log in by device 85 NR USE IMA VO Input the serial number of device and the verify code to monitor and control the device directly

Download Pdf Manuals

image

Related Search

Related Contents

  ECGシミュレータ  Micro-USB-Hub-v2, Mode d`emploi  AF3000 user manual - Edward Orton Ceramic Foundation  REDUCTOR - DSpace en ESPOL - Escuela Superior Politécnica del  TESTS SIMPLES ET MULTIPLES SIMPLE • RAPIDE  request for proposal fire engine  Fiche conseil  Samsung 29A11 CRT Television User Manual  Hewlett Packard Enterprise V V1900-8G Switch  

Copyright © All rights reserved.
Failed to retrieve file