50097-076 Rev A
Contents
1. C electrical connection On Off power switch 4 CER Rear Panel Water Inlet Drain Solution In and Solution Out connections 5 Disinfectant Reservoir Tubing connections AC power temperature control and display 6 Water Filtration System 1 0 micron pre filter and 0 2 micron absolute filter 7 CER Cart if applicable 8 Transfer Pump optional 9 Active Vapor Management System if applicablel Fluids 1 High Level Disinfectant HLD Rapicide HLD OPA or Glutaraldehyde 2 Detergent optional recommended detergent is Medivators Intercept 3 Alcohol 70 isopropyl used to dry inside of endoscope channels 4 Test Strips used to test the HLD prior to each cycle FLUID LOADING AND UNLOADING High Level Disinfectant HLD 1 Amount of HLD disinfectant required 4 gallons for CER 1 5 gallons for CER 2 2 Loading disinfectant reservoir using Transfer Pump 3 Unloading disinfectant reservoir using Transfer Pump 4 Loading disinfectant reservoir using manual method 5 Unloading disinfectant reservoir using manual method 6 Setting Adjusting disinfectant reservoir temperature for heated disinfectant 7 Disinfectant neutralization and disposal optional 8 Cleaning the disinfectant reservoir SYSTEM OPERATION Run the Reprocessing Cycle 1 Close CER lid and secure using lid locks 2 Cycle Selection Automatic FULL or LCG RINSE 3 Confirm Tim
2. e Settings Wash and LCG 4 Select START to begin cycle 5 Basin thermometer HLD temperature verification Complete the Reprocessing Cycle 1 Verify STOP LED now illuminated 2 Alcohol Flushing Port w air on Manual air 10 Start 3 Record Endoscope Cycle completion in Log 4 Disconnect hook up and remove and store reprocessed endoscope s and hook up s End of Day Shutdown 1 Water Supply Valve End of Day OFF 2 Clean basin lid and gaskets Use lint free cloth MAINTENANCE TROUBLESHOOTING Weekly Maintenance Troubleshooting 1 Clean CER reprocessor and basin 1 Review troubleshooting section in CER User Manual use lint free cloth 2 Service Contract Coverage and Loaner Repair Program 2 Inspect CER reprocessor and hook up components for wear and tear 3 Lubricate O rings with silicone oil Monthly as specified 1 1 0 micron water pre filter replace every 3 months or if below 40 PSI 2 0 2 micron absolute filter replace every 6 months or if below 40 PSI 3 Installation and disinfection of filters and filter housing upon 0 2 micron filter replacement 4 Active Vapor Management System if applicable Charcoal filter replace every 6 months Medivators Website Resource Center Go to www minntech com medivators Select Resource Center and User Library for detailed user guides and hook up matrice
3. m Ta a a IN SERVICE GUIDE CER 1 amp CER 2 FOR FACILITY USE ONLY Staff Name Training Date Trainer MEDIVATORS OPERATOR CONTROLS 1 Automatic Operaton FULL Cycle 2 Automatic Operation LCG Rinse Cycle 3 LCG Time 4 Air 10 minutes 5 Manual Operation LCG In 6 Manual Operation LCG Out 7 Manual Operation Drain 8 LED s Blinking 9 Start 10 Stop 11 Alarm Reset LCG and Water Level Verification 12 Alcohol Flush 13 Cycle Counter SYSTEM OPERATION Start up 1 Verify power is on Daily Service 1 Perform Daily Quality Assurance Procedure 2 Water Supply Valve Start of day ON 3 Water Flow Verification 100cc s 4 oz in less than 15 seconds through each hook up port 4 Air Flow Verification Confirm vigorous bubbling from each hook up port 5 Verify disinfectant level in reservoir 6 Check disinfectant reservoir temperature 2 C higher in reservoir for correct basin temp 7 Check HLD expiration date temperature and potency level with test strips 8 Check drain screen and cover for debris 9 Inspect hook ups for wear Prepare Endoscope for Reprocessing 1 Place endoscope control section in lower right with light guide in the back middle 2 Place accessory bag into basin away from drain 3 Locate proper hook up and connect hook up to endoscope ports and basin connection Endoscope Rep
4. rocessing Cycle Summary 1 Wash Phase optional 2 Rinse Phase 3 Disinfection Phase 4 Rinse Phase 2 if using Rapicide or Glutaraldehyde 3 if using OPA 5 Air Purge Phase 6 Manual Alcohol Flush Phase MEDIVATORS INTENDED USE AND GUIDELINES Intended Use 1 CER Endoscope Reprocessor High level disinfection of flexible immersible endoscopes 2 Operator Safety Overview appropriate PPE mask gown gloves eye protection Guidelines for Reliable Disinfection 1 Detergent solution used in wash cycle must be low foaming free rinsing neutral in pH and diluted per manufacturer s recommendation 2 Disinfectant solution required for high level disinfection cycle 3 Olympus Pentax Fujinon Storz Endoscope cleaning and disinfection guidelines 4 SGNA ASGE ASTM APIC and AORN Endoscope cleaning and disinfection guidelines 5 SGNA Approved Reprocessing Steps Endoscope bedside pre cleaning leak testing manual cleaning high level disinfection final drying and storage standards and guidelines PRODUCT FAMILIARIZATION Endoscope Reprocessor Components and their Functions 1 CER Front Panel Control panel keypads and LED indicators cycle counter and alcohol flushing port 2 CER Basin Lid and lid locks channel connectors endoscope hookup fluid level sensor drain screen and cover and basin thermometer if applicable 3 CER Side Panel A
5. s report forms and logs and product bulletins Medivators Customer and Technical Support Toll Free Phone 1 800 444 4729 FAX 1 866 421 7696 MINNTECH CORPORATION All rights reserved 50097 076 A