1. To switch the mode of operation back to Open Mode you would send the unit the following SMS Message PWD654321 ACM0 and you should receive the following SMS message back from the unit if sent correctly ACM OFF To switch the mode of operation to Security Mode you would send the unit the following SMS Message PWD654321 ACM2 and you should receive the following SMS message back from the unit if sent correctly ACM ON Adding and Deleting Numbers in the White List The system will accept up to 99 Mobile or Landline numbers that are authorized to access the system and to store these numbers in the authorized list you can use the following format as from 01 up to 99 and to store number one number in the list you would send the unit the following SMS Message assuming the number as 07123456789 and it is not required to enter the 0 PWD654321 WHLO01 7123456789 you should receive the following SMS message from the unit if sent correctly WHLO1 7123456789 This format applies up to the last number as PWD654321 WHL99 To delete any numbers in the list you would send the following SMS Message to the unit and assuming you were deleting telephone number one of the authorized list as WHLO1 7123456789 PWD654321 WHLO1D you should receive the following SMS message from the unit if sent correctly WHLO1D lt OK gt and number 1in the authorized list has been deleted Checking a telephone Number in the Security List If you want t
2. PWD654321 RLY2 03600 and you should receive the following SMS message from the unit if sent correctly RLY2 03600 and Relay one has latched for a period of 3600 seconds Page 3 www quantek co uk User Manual V1 6 Latching the relays permanently and It is possible to latch both relays either On or Off permanently and this will not affect the default setting of Relay one but the command to latch for the 1 second will obviously be ignored if the Relay has been programmed to be permanently switched On To Latch Relay 1 On permanently you would send the following the SMS Message to the unit PWD654321 RLOP1 1 and you should receive the following SMS message from the unit if sent correctly RLOP1 ON and Relay one has been latched permanently On To Latch Relay 1 Off permanently you would send the following the SMS Message to the unit PWD654321 RLOP1 0 and you should receive the following SMS message from the unit if sent correctly RLOP1 OFF and Relay one has been latched permanently Off The same format would be used for permanently latching Relay 2 On and off using the commands as RLOP2 1 and RLOP2 0 Receiving SMS Text alerts and messages from the unit It is possible to receive SMS alert messages to confirm both relay latching has been implemented and also when the Relays Latch off In addition it is possible to receive SMS text alerts when the Input is activated as described in the Alarm Functions section The system can se
3. every 4 seconds Ensure the SIM has credit 4 The unit occasionally activates itself Network operators often make marketing calls to their subscribers switch on secure access mode so only numbers in the white list can activate the unit 5 The unit has been working for several months and has now stopped responding to calls and text commands Most but not all PAYG SIM cards will be de activated by the network if not used to make an outgoing voice call or send an SMS text message within a specific period of time To prevent this simply send the GSM G a text command it will reply by text message do this once a month to keep the SIM card active 6 When call the unit do not receive a confirmation text message The unit only sends relay status messages in response to the RLOP and RLY commands 7 After initial setup the relays can only be activated by text and not by my calls Ensure the voicemail feature has been disabled on the SIM card Ensure the number is in the White List Page 7 www quantek co uk User Manual V1 6
4. unit the following SMS Message PWD123456 CAP654321 CAP654321 and this is sent in this format as confirmation and you should receive the following SMS message from the unit if sent correctly CAP 654321 and the new password is now 654321 this will be used for the following examples Checking the Signal Strength The next thing you may wish to do is check the actually signal Strength at the location and to do this you would send the unit the following SMS Message PWD654321 CSQ you should receive the following similar SMS message from the unit if sent correctly CSQ lt 12 gt This indicates the signal strength of lt 12 gt from a range of between lt 1 gt and lt 31 gt It is advised that if you are registering a signal strength any lower then lt 5 gt or lt 6 gt you should add an additional external antennae to improve the signal strength or change the Network Page 2 www quantek co uk User Manual V1 6 Security Mode The system can store up to 99 numbers that are the numbers that would be authorized to access the system by calling the unit and this mode of security can be tuned on or off to suit the customer requirements These 2 modes are either Open Mode in which any person calling the unit can access the system not recommended as number may receive marketing calls or Security Mode which restricts access to the numbers programmed into the system White List The Factory default is set to Security Mode
5. C Prox 44 0 1246 417113 sales cproxltd com www quantek co uk Ez Low voltage device Gates Cameras etc Multi Function GSM Controller Introduction The GSM G has been designed to operate Gates and other electrical devices using your existing Mobile Phone or Land Line and also eliminating the problems that occur with low range wireless remote controls as this system has no range barriers This system allows the administrator or user to operate two separate relays One using caller ID to active Relay 1 automatically with a voice call or alternately it is possible to SMS the system to activate Relay 2 to perform another function Another feature is an Alarm Input function which has the ability to send up to 8 separate SMS alerts in the event of an incident such as a power failure or an alarm being activated and a personal customized message can be programmed into the system The system comes with a built in power supply and external antenna and only requires a valid SIM Card Please read through the instruction manual before you start to install and program the GSM G Power Supply The Integral Power supply of 12 Volt DC supply capable of providing 1 Amp current never use the power supply from Gate control panels as they may show a 12 Volt reading and initially Log on to the system but can draw higher current when Network signal strengths drop and not only log off but may also blow the fuses on the
6. Gate control board as GSM Modems will draw excessive currents whilst searching for the network connections SIM Card The system will accept any Universal Network GSM SIM Card UPDATE Vodafone PAYG SIM cards no longer work It is essential that you remove any Pin Code requests from the SIM Card which can be done by placing the SIM Card in an unlocked Mobile Phone and using the features on most Mobile Phones to disable the Pin Code request as if the Pin Request is enabled the system will not log on to the network and the unit will refuse to be programmed In addition it is essential you also disable the Voice Mail function which can be in some case done again by placing the SIM Card in an unlocked Mobile Phone and contacting your service provider to remove this function and insure the SIM Card does not accept or store any incoming voice messages Page 1 www quantek co uk User Manual V1 6 Mobile Phone Credit It is also essential that the SIM Card is retained with enough credit at all times so as to be able to receive the SMS text alerts when making any changes to the system remotely even though the system will continue to perform and make the changes required although you just will not receive the confirmation text messages back from the unit In addition the system will still operate by calling the unit and opening the Gate as there is no connection charge for using this function Installing the SIM Card and booting up the system To Install th
7. alarm Input connection for a period of 5 seconds and to customize the SMS Message you would send the following SMS Message to the unit assuming the required message is to be Gate Forced PWD654321 STR Gate Forced and you should receive the following SMS message from the unit if sent correctly STR Gate Forced and this SMS Message will now be sent to the administrators from the TEL list that are programmed the Matrix to receive the SMS text alerts Setting up the Alarm Input Message when De activated It is also possible to Program an alarm message that is sent when the alarm Input returns to normal status or Alarm Power is removed and to set the following message as Gate locked again you would send the following message to the unit PWD654321 STO Gate locked again and you should receive the following SMS message from the unit if sent correctly STR Gate locked again and this SMS Message will now be sent to the administrators from the TEL list that are programmed in the Matrix to receive the SMS text alerts Setting up the alarm status Modes Power applied and Normal status The system allows you to send just an alarm message when the power is applied and no alert messages when the power returned to normal and this is done by sending the following message to the unit PWD65432 CTC 5 and you should receive the following SMS message from the unit if sent correctly CTC lt 5 gt you will onl
8. as On and 0 as Off as follows The factory default has set up the RERN as RERN 10000000 which indicates the first administrator number in the list will receive the SMS text alerts and messages and the remaining seven administrators will not receive any SMS text alerts or messages To change the Matrix of persons who will receive the SMS alerts or messages you would simply use this format and to assume we want only administrator 1 4 and 6 to receive the SMS alerts and messages we would send the following SMS message to the unit PWD654321 RERN 10010100 and you should receive the following SMS message from the unit if sent correctly RERN 10010100 and only the administrators 1 4 and 6 will receive the SMS text alerts and messages To change the matrix you would just over write the existing matrix by sending anther SMS message to the unit and if you want to send more than one message to one off the Administrators you would simply enter that administrator in the TEL list the number of times you want them to receive the SMS text alerts and messages Page 4 www quantek co uk User Manual V1 6 Setting up the Alarm Input Message when activated The system has an alarm Input that will trigger a customized SMS text alert to the administrators as recorded in the TEL list and activated in the Matrix to receive the SMS text alerts and you also need to have the CTR 1 alarm function turned On This alarm is activated by applying a 12 Volt DC supply to the
9. e SIM Card you will need use a small pointed screw driver and depress the small yellow button beside the SIM Card tray as labeled SIM Card and the SIM Card tray will pop out You can remove the tray and locate the SIM Card in the holder and gently slide the SIM Card tray back into its receiver slot Don t ever force the SIM Card tray or attempt to remove it out with a screw driver by levering it as you will only damage the unit and render it useless The Red power light will come on and the Green network light will oscillate infrequently until it locates the network once it has secured itself on the network the green Network light will flash every 4 seconds constantly If this does not happen after say one minute the system has not logged on and you will need to check the SIM Card is positioned correctly and that the antennae is connected or it may be the signal area is too low Once the system is connected to the network it is now possible to actually Change the Password if required and then check the Signal Strength at the location using SMS Messaging Password All SMS Commands are sent to the unit with a Password prefix which is factory set as default of the password digits of 123456 PWD123456 and this format is the prefix to any commands sent to the unit and all of the commands are always sent in CAPITAL letters with no spaces or symbols It is possible to change this password if required and to change this to 654321 you would send the
10. nd these SMS text alerts to 8 separate Mobile phones in the sequence they were programmed into the system and referred to as administrator numbers 1 8 and can also be toggled on or off remotely via a Matrix as explained in the Administrators Matrix section Programming in the Administrator Numbers The Administrator numbers are programmed into the system using the command TEL1 through to TEL8 and to program TEL1 you would send the following SMS Message to the unit PWD654321 TEL1 07847070001 and you should receive the following SMS message from the unit if sent correctly TEL1 07847070001 When programming the administrator numbers always enter the full telephone number and if you wish to receive SMS alerts whilst abroad always put the complete number in including the International code as this is the number the system is programmed to transmit the SMS text alerts to The remaining administrator numbers are programmed in the same format to TELO8 Administrators Matrix Once you have programmed in the administrators numbers it is possible to also now program a matrix of who should receive the SMS text alerts and confirmation messages The system is pre set as factory default to send TEL1 SMS text alerts and messages once that number has been entered and confirmed in the TEL1 and the CTR 1 alarm function turned On The Matrix is programmed using the RERN command which can toggle the list of numbers On or Off based on using the digit 1
11. o check any number in the authorized list you can do so by sending the following SMS Message to the unit as assuming you are checking number one in the authorized list PWD654321 WHLO1 and you should receive the following SMS message from the unit if sent correctly WHLO1 7123456789 Setting up the Output relay one Latching time when called This function sets the actual latching time when you call the unit and is factory pre set at 1 second but it is possible to extend this latching time up to 60 seconds To reset the latching time to 5 seconds for say a Magnetic Lock you would send the following SMS Message to the unit PWD654321 GOT05 and you should receive the following SMS message from the unit if sent correctly GOT 05 and the Output Relay one will now latch for 5 seconds whenever the unit is called Temporary latching any or both relays It is possible to temporary latch both relays independently and in the case of relay one this does not affect the default setting of the GOT command Both relays can be temporary latched from 1 second up to 65 000 i e 18 hours and to latch Relay one for a period of 3600 seconds you would send the following SMS message to the unit PWD654321 RLY1 03600 and you should receive the following SMS message from the unit if sent correctly RLY1 03600 and Relay one has latched for a period of 3600 seconds To Latch Relay two for a period of 3600 seconds you would send the following SMS Message to the unit
12. rectly REST OK and the system has now been restored to factory default The password is now restored to 123456 the default latching time for Relay one is 1 Second and the system memory is now blank And will require reprogramming from the beginning So please note this when sending the REST command Page 5 www quantek co uk User Manual V1 6 PWD123456 CAP CSQ WHL WHL D WHL99D WHL GOT 01 60 RLY1 RLY2 RLOP1 RLOP2 TEL 01 08 STR STO CTC 5 CTC 6 CTR1 CTRO ACMO ACM2 REST Page 6 LIST OF SMS COMMANDS www quantek co uk User Manual V1 6 Schematic Wiring Diagram Output Relay 1 Clean Contacts R2 Clean Contacts Power Contact R2 v Relay 1 Phone call operation Relay 2 Text operation Trouble Shooting 1 Red power LED not alight Check that the power supply is connected into the right terminals and that there are no loose connections 2 Green network LED is NOT flashing every 4 seconds Ensure that your SIM card has been activated and that the PIN request has been disabled Make sure the SIM card has been inserted correctly If the unit is in a low signal strength area consider using an external antenna or changing to another network provider 3 am not receiving text messages when initially programming the unit Ensure the unit is connected to the GSM network by observing the green network LED it should be flashing
13. y receive the message as programmed in as with the STR Gate Unlocked when the Voltage is applied to the Input alarm connection To receive the STR alert message when the Voltage is applied and also to receive the STO message when the input Voltage is removed you would send the following SMS message to the unit PWD654321 CTC 6 and you should receive the following SMS message from the unit if sent correctly CTC lt 6 gt and the administrators programmed to receive text alerts will receive both messages To receive either alert messages one or the other of the CTC 5 or CTC 6 have to be programmed into the system otherwise the alert messages will not be sent and also the following alarm function must be turned on Turning the Alarm function On and Off The alarm function can also be turned on or off if required and to turn this function on you would send the following SMS Message to the unit PWD654321 CTR 1 and you should receive the following SMS message from the unit if sent correctly CTR ON and the Alarm Function has been turned on To turn this function back off you would use the command CTR 0 you should receive the following SMS message from the unit if sent correctly CTR OFF and the alarm function has been turned off Resetting the System The system can be reset to factory default by sending the following SMS Message to the unit REST 654321 and you should receive the following SMS message from the unit if sent cor
Download Pdf Manuals
Related Search
Related Contents
269Ts TRONÇONNEUSE 269TCs TRONÇONNEUSE 320Ts HumaPen Luxura HD - Eli Lilly and Company 平成24年4月27日 消費生活用製品の重大製品事故に係る Avocent MPU for Dell Release Notes v_1_22_1 dB300a - Samson FICHA TÉCNICA DE REVUELTO GAMBA, AJETE Valueline VLSP40010W200 coaxial cable Adwa Hungary kft. English - Soulution Installation and Operations Manual Claritech RT-1 Copyright © All rights reserved.