1. I oO 0 Computer 4 atl Multifunctional Monitor amp Logger Powerlog 6S Program flow chart Logo Screen Inf Screen TYPERSOO0O0O0 0 LOGSRUERAT EIN S N XXXXXXXXXX PowerLog PowerLog6os 4 Data Log o is shown in the upper right POWER ON aD OO www hillrc com 1988Kb 16h 34 Logs OFF corner blinkingly e Transfer data to USB port e Save data to the appointed Log File lt HOLD gt lt HOLD gt gt 3 Seconds gt 3 Seconds Monitor Watt monitor Cells monitor 003015mAh 20m 10 CELLS MODE Differencemy OdAuto Differenc OEach Voltage 10 50A 2 4 O87VEh4 162V NAO et lt MENU gt KARA anas gt 3 Seconds Tachometer monitor TACHOMETER TORIC lt A gt V gt gt 3 Seconds RPN 1200 27 1025 8 30 7 00000297 2D6 Mae Zi MO Ie 3255 00000297d187 8195 0 19000us Max ERO Lado ULLQNULL gt lt not used gt econas PWM monitor TEMP SENSOR LIST Note When you turn off the PowerLog6S it will remember the current screen and start from that screen when next turned on again lt TYPE gt lt MENU gt SE gt 3 Seconds gt 3 Seconds lt MENU gt 3 Select Main Menu SE gt 3 Seconds Details in next page Select Type Q ALARM SETTING Cells Voltag q CELLS VOLT ALARM MAX S SA Se Lee Wels LiPo gt LiPo
2. FE 3 CO Jonsi Upgrader Verl 5 Copyright C 2010 Jansi T Include COMs Port Updates List iCharger Release Notes Updated iCZ08B_ 313b S01 0 03 01 iC206B 313b S01 0 03 01 ICLOLOB _ 313b S01 0 03 04 CellLagtasi_v207 2009 11 27 Device List Select Update File D PowerLog PowerLog s_ 102 bin Open Download a iCLOLOB Y313b 2010 03 01 iC1068 Y313b 2010 03 01 iC3010B_ 313h 2010 06 17 FowerLog 65 PowerLog s w102 201007116 File Information Sar Save as M Version W102 Type PowerLog Wit PowerLog sVi02 bin Memo 2010 07 16 et Upgrading 21 FA Multifunctional Monitor amp Logger Powerlog 6S Using LogView for PowerLog 6S First our sincere gratitude to the LogView development team http www logview info Communication steps To install LogView run the program X logview LogViewlnstaller exe where X is the drive letter designator for you CD ROM drive e Connect the PowerLog 6S to the PC using the supplied USB cable e Start LogView then follow the illustrated instructions below 1 Please choose language first since the default language is German File Edit Device Graph Analysis Tool View Help pen le Save E Save As History d Import Devicefle Export table Export graph F Send graph as eMail Google Earth Export KIL FE Language Deutsch w CO 44
3. replaced to be the current value Setting range T plug Voltage 4 5 60V Current 130A 130A Capacity O 999999mAh Power 800W 7800W 8 Multifunctional Monitor amp Logger Powerlog 6S 2 Cells Monitor Monitor the input voltage of Multiple Voltage Input Port J3 rer mer Max Voltage Voltage Sum the sum voltage of Cell Voltage 1 6 ae R N Difference NV Max Cell Voltage Min Cell Voltage 14 087VE44 162V J 4 120VI9 4 nf ENE Cejl Voltage 3 lt MENU gt lt A gt lt V gt gt 3 Seconds gt 3 Seconds CELLS MODE Differencemmm OAtito Difference OEach Voltage ND 2 V1 3 V2 4 V3 5 V4 6 V5 V6 HF lt A gt or lt V gt lt A gt or lt W gt BSAA PEAK Min il 4 no 4 150V 4 OSOVE 4 160V J 4 110V lt A gt or lt V gt Zo IN 3 4 130VE i 4 120V 4 172V 4 097V 4 192V T is in front of the cell with Max Cell Voltage while 1 is in front of the cell with Min Cell Voltage Setting range V1 V6 0 05 28 00V Difference Displayed voltage CellVn Vn Vn 1 1 lt n lt 6 under the condition V6 gt V5 gt V4 gt V3 gt V2 gt V1 gt 0 Auto Difference First sorting by ascending numeric sequence between V1 V6 then has Vai Va6 CellVn Van Van 7 1 lt nS lt 6 Each Voltage Displayed voltage CellVn Vn 1 lt n lt 6 Press lt A gt or lt Y gt can shift among the interfaces of current value Min peak value and Max peak va
4. PowerLog 6s Multifunctional Monitor amp Logger FA Multifunctional Monitor amp Logger Powerlog 6S Thank you for purchasing the PowerLog 6S Please read the User s Manual completely and attentively as it contains lots of specific operations and safety information PowerLog 6S is one compact multifunctional monitoring and logging meter adopting 32 bit ARM processor with 12 bit A D convertor to ensure the accurate measurement Specifications Input voltage range 4 5 60 0VDC Current measurement range 130A 130A continuance 40A 40A Cell voltage range 0 05 28 0VDC External temperature measurement range 55 C 125 C 67 F 257 F Pulse measurement range 10us 999999us Pulse width output range O 20ms 0 5us step Tachometer measurement range 0 99999 RPM Voltage resolution accuracy 0 001V 0 5 Current resolution accuracy 0 01A 5 Current loading of test 12mA Maximum voltage for alarm port SOVDC Current drain for alarm port lt 500mA Log files storage 16Mbit 33 hours 2 seconds logging interval Sample logging time interval 0 25 3600 seconds PC connect USB port Weight 29g Dimensions L X W X D 85X40X13mm 3 34 X1 57 X0 51 Special features PowerLog 6S allows bidirectional current sensing adopting 0 2 MQ current sampling resistor with low insertion loss 1 channel 0 60V voltage measurement 6 channels cells voltage measurement can not only
5. Select i OLilo Rename Pack Voltage Fite AlarmkTrigger Timer Over Ose Current OUser2 Power Cisse ss Capacity OUser4 Temperature PACK VOLT ALARM Cliseres RPM MAX MOm be Period MIN O 000OV TA Pulse DIFFS 0 A A MIN RER 00 D TFF O A POWER ALARM RPM ALARM PULSE ALARM TIME OVER ALARM AX Eeo AX REERORN YIT MAX B KKENER Minutes 0 99999 IN t UN IN ie RPM MIN iG us 120 M D I FFER E00 IND 99990 RPMbI DIFFEREN CAPACITY ALARM TEMP ALARM RERIOD ALARM CURRENT ALARM 100 999900mAh AX Bee MAX REEERE MAX EEEO A 999900 M IN O MIN go us MIN Ga O DIFFERE DI FF RRR STORES Digg 260 0A M Note D means if no operation on the button for 3 minutes the system will return to monitor screen automatically 6 0 4 Multifunctional Monitor amp Logger Powerlog 6S D Monitor moes Details in previous page D means if no operation on the button for 3 minutes the system will return to monitor screen automatically lt TYPE gt lt MENU gt D gt 3 Seconds gt 3 Seconds B Main Menu MAIN MENU LOG FILE LogFilel Log Files RS Logs OFF Bo File Select BY PWM Output OLogFilel File Transmit Motor KV Meter File Empty System File Delete Calibration PWM OUTPUT PWM OUTPUT MANU anual Ry uto 1000 0 Setting PWM ADJ RANGE SER 10 0 us MIN LUV URE MAX SEAU OMIE 1000 0 2000 Qus CALIBRATION Default o OUser Setting VOLE SK PWM OUT
6. Time over alarm 3 ALM port will output the presetting signal ALM port signal information ALM output port signal is open collector signal as showed below Aoun Please pay attention to the port voltage and current limit when you use lt 50V lt 500mA The following are ALM Output typical application VCC VCC Output t ALM ER ALM Level Output Relay Output 12 FA Multifunctional Monitor amp Logger Powerlog 6S Monitor Alarm Settings The system can have 8 sets alarm settings press lt A gt for 3 seconds to enter SELECT TYPE menu SELECT TYPE The item with is the current setting OLio E lt A gt or lt Y gt to select items and press lt gt button to confirm OLilo Defaulted TYPEs are LiPo Lilo LiFe User1 5 OLiFe i LiPo Operate the selected type settings a lt A gt or lt W gt to select the items press lt e to enter the next step Rename i Alarm amp Trigger See details below Change Present Alarm Type Select Select Press lt gt then the item will be with and the settings come into effect Rename Alarm Type Select Rename press lt gt and the screen shows FE New Name Input Method lt A gt to select characters hold it to trigger ek continuously until you get the character you need the second cycle of New Name 26 characters will be capital letter lt W gt to delete the current character lt gt to confirm the selected character press lt gt for 2 times
7. amp Logger Powerlog 65 e PWM Output Select PWM Output and press lt gt and the screen shows PWM OUTPUT lt A gt or lt W gt to select items press lt gt button to confirm press lt gt Manual E for more than 3 seconds to return Auto See details below Setting 1 PWM Output Manual Select Manual press lt gt and the screen shows PWM OUTPUT MANU lt A gt or lt W gt to increase decrease value press lt gt button to 1000 0 confirm press lt gt for more than 3 seconds to return The fourth line displays the value setting range If adjust range see Ae AU details as PWM SETTING gt PWM Adjustable Range Settings 2 PWM Output Auto Select Auto press lt gt and the screen shows PWM OUTPUT AUTO Pulse width increases automatically When reaching the Max value it 1000 0 shifts to the Min value This process goes round and round Press any button to start stop the process of automatic pulse increase The fourth line displays the value setting range If adjust range see details as PWM SETTING gt PWM Adjustable Range Settings 1000 0 2000 Ous 3 PWM Settings Select Setting and press lt gt and the screen shows PWM OUTPUT SET lt A gt or lt W gt to select items press lt gt button to confirm press lt gt Range EL for more than 3 seconds to return Auto Speed meme See details below a PWM Adjustable Range Settings Select Range and press lt gt a
8. 2 seconds logging interval Support upgrading the hardware program by USB port Adopting HID protocol dispense with installing driver from PC plug and play The PowerLog 6S supports the Logview software and can display plot and analyze the data by it See detail information about Logview in the following website http www logview info 2 h F Multifunctional Monitor amp Logger Powerlog 6S Unpack inspection Standard items The following items are included in the package Contact your supplier if any items are missing CW USB5 10mm 12AWG Optional items The following items are not included in the package 3 at Multifunctional Monitor amp Logger Powerlog 6S External controls and connections U 8 2 3 9 10 11 1 Beep 2 Input T plug T1 3 Output T plug T2 4 Tachometer Sensor 5 LCD screen 6 Buttons 7 Pulse I O J1 8 Temperature Sensor Port J2 9 Multiple Voltage Input Port J3 10 Alarm Port 11 USB Port PowerLog 6S Connection Diagram Temperature sensor 2 or 5V Power it Pulse Input PWM Output Measures RPM vv LN r RPM I P BATT Measures motor KV PACK __ 4 5 60V E Brushless Brushed motor 654321 S POWER i charger i nn JL N an I oo an OR LOAD ESC oons on i I A I O1 0
9. 6S 9 Power Management Select Power Save press lt gt and the screen shows lt A gt or lt W gt to select the items press lt gt button to confirm and the POWER SAVE SET Not Save ae item will be with press lt gt for more than 3 seconds to return OFFER Not Save it will work as usual OSleep Mode Light Off it will turn off the backlight after minutes not working with any key the time can be set by the users Press any key to return to the normal status Press lt gt to enter to SAVE TIME SET Sleep Mode it will turn to Sleep Mode after minutes not working with any key for more than 1 seconds the time can be set by the users Press any key to return to the normal status Press lt gt to SAVE TIME SET enter to SAVE TIME SET Minutes 1 240 005 lt A gt or lt W gt to increase decrease press lt gt to confirm amendment and return Press lt gt for 3 seconds to cancel amendment and return Setting range 1 240 Minutes Calibration Settings Select Calibration and press lt gt and the screen shows CALIBRATION Default Ww OUser Setting Default Calibration Default calibration made by the manufacturer before delivery User Setting Calibration by users When itis press lt e gt to lt gt enter User Calibration menu The current need to be calibrated item begins to blink If the displayed M ee a f Current AA Eaa Pls Volt
10. gt Motor KV Meter P17 Wire Connection Methods of Mode0 and Model as the picture below Brushless motor Brushed motor Battery 4 5 28V RPM senor Hall senor 1 2 3 4 5 6 PIN 7 MODE 1 Notes 1 When measuring KV on the Mode O the throttle settings of ESC needs to be set at the Max value 2 If the tested voltage is lower than 4 5V PowerLog needs auxiliary power supply ia EET e Data Logging When in Monitor status press lt W gt button for 3 seconds after it shows Start logging the will be shown alternatively at the upper right corner of the LCD screen In this status the system will transmit the data to USB port every X seconds this interval time X can be set by user himself details you can see Record Interval Time Settings in P19 and save these data to the current Log file See Log File Management in P15 If Logs OFF the system will not log file Press lt W gt for 3 seconds again the screen will show Stop logging and then exit Alarm Remind If PowerLog detect the alarm events See Alarm Parameters Settings in P13 it will remind as below 1 The buzzer beeps every 4 seconds See Beep Tone Settings in P17 Alarm Tone is selected M 2 The corresponding value and alarm remind show alternatively Alarm Remind Information LOW Lower MIN limit alarm OVER Over MAX limit alarm DIFF Difference alarm T OVER
11. measure 1 6S Li NiIMH NiCd Pb battery individual voltage but also measure 6 channels 0 05 28V voltage 4 channels temperature measurement 1 channel internal temperature measurement and 3 channels external temperature measurement Propeller RPM measurement adopting non contact optical sensing user settable blade number PWM signal measurement frequency period pulse width duty cycle Applicable to remote control channel signal measure and monitor PWM output manual and auto mode auto mode is able to break in servos electronic speed controllers R C switches etc Motor KV measurement The 2 wire mode is suitable for the KV measurement of brushless motor while 3 wire mode is suitable for the KV measurement of both brushed and brushless motors Small size with multiple functions backlight 128764 lattices LCD and Buzzer Tone Reminder the interface can be operated smoothly It can be set Cells Voltage Pack Voltage Timer Over Current Power Capacity Temperature RPM Period and Pulse Alarm What s more the extra alarm output can be linkage controlled by the users It has 8 sets default monitor alarm settings which can be selected for different battery packs PowerLog 6S has been 100 calibrated before it enters to the market at the same time it supports the calibration by users themselves The logging interval can be set by users different needs PowerLog 6S has a 16Mbit flash storage which can log offline data in 33 hours
12. number the displayed information is as below Aca coniiewanon Nome The first line is the current selected Setting Type See Existent Log Files Number details in P13 The second line shows the log file 0 ME 2 6 Record Interval Time number And the third line is the available record of aoa gegen Free Capacity Free Time capacity and time The last line shows the current log file COR CRD EDE LE NAME name if no files it shows Logs OFF 3 seconds later the system enters voltage monitor status Monitor There are 5 interface choices which can be shifted by lt gt button 1 Watt Monitor Monitor the input voltage and current of Current zero point calibration T plug When there is no current flowing through T Plug if the displayed current is not zero please press Capacity on NE Timer lt A gt lt V gt lt gt for 3 seconds lt A gt lt W gt lt gt means 10 504 Correri pressing lt A gt and lt gt lt gt at the same time SATIRE T plug Voltage ar UN IBAS jk Power l Reset Timer Press lt A gt lt V gt for 3 seconds the time on the upper right corner becomes 00m 00 and the capacity on the upper left corner becomes OmAh lt A gt or lt V gt Press lt A gt or lt Y gt can shift between the interface of the current value and the peak value PEAK Min Max 0 00A 10 80A Reset peak value LES BY i OW 127 3W Press lt A gt lt W gt the Min and Max peak value will be
13. setting of the clock for the interface of Watt Monitor lt A gt or lt W gt to select the items and press lt gt to shift select W L press lt gt for 3 seconds to confirm the amendment and return Select Start the clock starts when the T plug has the flowing current Select Pause the clock pauses when the T plug has not the flowing current Select Clear Time the clock clears to 0 when the current of T plug starts from scratch Select Clear mAh the mAh clears to 0 and recounts when the current of T plug starts from scratch 7 Record Interval Time Settings Select Rec Interval press lt gt and the screen shows RECORD INTERVAL 0 25 3600Sec 2 See 8 Start up Settings Select Start START SETTING Start Music Bi ILOG Screen MInf Screen lt A gt or lt W gt to increase decrease press lt e to confirm amendment and return Press lt 4 gt for 3 seconds to cancel amendment and return Setting range 0 25 3600 Seconds press lt gt and the screen shows lt A gt or lt W gt to select the items and press lt gt to shift select W L press lt gt for 3 seconds to confirm the amendment and return Select Start Music there will be a start music if you turn on Select LOG Screen it will display Logo Screen if you turn on Select Inf Screen it will display Information Screen if you turn on 19 oy F A Multifunctional Monitor amp Logger PowerLlog
14. Donationware 19 close rs I a 2 Click Device gt Choose device and port SiLog ier YZ 7 0 Mm Corre ak Open port no recording FF capa 2 Open port 7 recording W Temp Internal 22 f Fy Multifunctional Monitor amp Logger Powerlog 6S 3 Choose Junsi PowerLog 6S from the list and then choose the correct communication Port EF n T VST 8 Fie Edt Dawe Graph Andyt Took View Hain bede his CN PRESdM aA Me Wok gt osen Dm Sturt recording ane o RA i e Temp Eit hf lemp Ext sie Powel og B5 F temp Bet 3 ae 7 aia logge E Pibe Period sn ac unto m r to Pos Pulse Width ncn oc fe Cell f Zez Aonais Hui aoid p Cay Bude ge fio ce FH ces Connechon cet Fle Edit Denice Grigh Anais Tocs View Hep gede smana DE AR f r lt work gt E Terps Inara HF Temp Ext I W Temp Ext 3 E Temp Ext 3 HF Pulse Period ff Bos Pulse Width E cel t W Cell 2 cals W Celi A ste m cells ne gt rl E x El IE les 2 R cele of Aof Fo aay po FF Power F a E 5 a a 5 E Start the logging function of PowerLog see P12 or enter the menu of Log Files File Transmit see P15 Refer to the LogView online help for more information about its features and operation 23 Multifunctional Monitor amp Logger Powerlog 6S Limited warranty PowerLog 6S is guarantee
15. LT ALARM PACK VOLT ALARM applies to the T plug voltage of Watt Monitor AX MOO interface MIN HORNS I b gaa 60 00Vv Mm Setting range 0 05V 60 00V MIN 0 00V 59 95V DIFF0 05V 60 00V 3 Monitor Time Over Settings Select Timer Over press lt gt and the screen shows TIME OVER ALARM TIME OVER ALARM applies to the Timer of Watt Monitor interface Minutes 0 99999 When monitor time is over the set value it alarms T OVER 120 M Setting range 0 99999 minutes 4 Current Alarm Settings Select Current press lt gt and the screen shows CURRENT ALARM CURRENT ALARM applies to the Current of Watt Monitor interface MAX RUN 0 C TA Bo le i MAX 129 0A 130 0A MIN 130 0A 129 5A DIFF0 5A 260 0A 5 Power Alarm Settings Select Power press lt e gt and the screen shows POWER ALARM POWER ALARM applies to the Power of Watt Monitor interface MAX ES UN F DRE 156000 og Seting tange MAX 7799W 7800W MIN 7800W 7799W DIFF1W 15600W 6 Capacity Alarm Settings Select Capacity press lt gt and the screen shows CAPACITY ALARM applies to the Capacity of Watt Monitor interface CAPACITY ALARM 100 999900mAh 999900 M When measured capacity is over the set value it alarms Setting range 100 999900mAh 7 Temperature Alarm Settings Select Temperature press lt gt and the screen shows TEMP ALARM TEMP ALARM applies to the Temperature of Temperature Monitor MAX 125 0C MW i
16. OM VIEW Every DS18B20 has a unique ID number Under the temperature monitor mode when a S N 000002983990 new sensor connects to it the system will check the ID number of the new sensor termer r ve automatically as picture 00000297d187 lt not used gt Eo Alternatively display Find new DS18B20 S N xxxxxxxxxxxx in the first line while from the second line to the fourth line it displays the ID number of the present T1 T3 sensors Press lt A gt lt W gt to choose the needed Tx while press lt gt and a new temperature sensor will be added in the menu Press lt e gt for 3 seconds to cancel the addition If there are other new sensors in this circuit the process will continue The temperature of the added temperature sensor will be displayed in the Temperature Monitor Interface 10 Multifunctional Monitor amp Logger Powerlog 6S 4 PWM Monitor Monitor the input pulse signal from J1 The measurement resolution of PWM is 1us eee Frequency Freq 1 Period A cea Period The smaller the Period the bigger measurement deviation Pulse duty cycle T R G Pulse width Pulse duty cycle REN SER Pulse width of Freq 5 Tachometer Monitor TACHOMETER Press lt A gt lt W gt for 3 seconds the number of propeller RPM 1206 RPM value blades begins blinking and then press lt A gt lt W gt to Max RPM Jos AR AE ade IEM Number of propeller adjust the value Press lt gt to confirm and retu
17. PUT AUTO PWM AUTO SPEED 00953 1000 0 Step Interval RP MOBY USR 1000 0 2000 Qus PWM OUTPUT SET PWM SIGNAL LEVEL Range Sie Auto Speed High Level OLow Level Level TIMER BY CURRENT start i SYSTEMESETTING Pause Temp Unit BK MClear Time Beep Tone MClear mAh LCD Screen TEMPERATURE UNIT Celsius C im OFahrenheit F Alarm Setting Log Start Timer Start RECORD INTERVAL Rec Interval 0 25 3600Sec e 2 Sec Power Save BEEP TONE Mikey Tone ViHint Tone ViAlarm Tone ALARM OUTPUT Toggle NO By OToggle NC Contrast OHold NO OHold NC START SETTING POWER SAVE SET ViStart music Be Not Save BO MiLogo Screen OBacklight OFF MiInf Screen OSleep Mode Brightness LOG AUTO START LOG START Manual St Bo OdAuto Start ALARM SETTING ALARM ACTIVATION Signal Out pulje MDelay Time EA Activation MLogging Pass Through Fy Multifunctional Monitor amp Logger Powerlog 6S Menu Operation 1 Select the menu items by lt A gt lt W gt buttons the selected item will be shown in white 2 Press lt gt to enter the submenu and hold lt gt for more than 3 seconds it will return to the superior menu Symbol Meanings total voltage of the pack n 0 6 the cell count the maximum voltage difference between the cells OO mM ss jor the timer ss second mm minute hh hour o L O R Lower MIN limit alarm OVER Over MAX limit
18. age value is more than the actual value please press lt W gt to decrease Cell3 Voltage SAMa Cell Voltage Q LEV i i Cell Voltage EROA i gg Cell2 Voltage the displayed value to the actual value vice versa please press lt A gt Cell5 Voltage 5 PAGE Cel Voltage to increase the displayed value to the actual value Press lt gt and shift to the next item In this way to get all the calibration Press lt A gt and lt W gt for 3 seconds to save the amendment and exit Press lt gt for 3 seconds to cancel the amendment and exit Note If the user calibrates it in a wrong way which damage the battery or cause other serious danger our company will be of no responsibility 1 In order to have more exact actual current and voltage value we suggest using 45 Digit Multimeter The users calibrated value will not affect the value calibrated the manufacturer It can be selected by CALIBRATION User Setting or Default 20 Fy Multifunctional Monitor amp Logger Powerlog 6S PowerLog Firmware Upgrade Steps e Run the program X Upgrader Upgrader exe you can download the Upgrader exe software from the following website http www jun si com UploadFiles Upgrader rar e Connect the PowerLog 6S to the PC using the supplied USB cable choose Device in Device List then select the upgrade file you can download the latest file The progress bar will appear after you click Update
19. alarm DIFF Difference limit alarm Button Function PowerLog has 3 buttons Each button owns two functions The first function is to trigger after only one click the second function is to trigger after holding the button for 3 seconds Click 1 Turn up the menu item 2 Increase the value 3 Select the input character Hold for 3 seconds Enter alarm type select menu lt y gt Click 1 Turn down the menu item 2 Decrease the value 3 Delete the character Hold for 3 seconds Trigger Start Stop logging function Hold for 3 seconds Enter system setting menu C Hold for 3 seconds 1 Reset timer watt monitor 2 Enter cells mode menu cells monitor 3 Adjust blades temperature monitor 4 Save user calibration interface lt A gt lt V gt t lt e gt Hold for 3 seconds Current zero point calibration watt monitor on watt monitor Interface Note lt A gt lt V gt means pressing lt A gt and lt W gt at the same time Multifunctional Monitor amp Logger Powerlog 6S QUICK START PowerLog Power On When connecting any of the following power sources PowerLog will be triggered ON Connect the USB port of PC Connect power supply 4 5 60V through T plug T1 or T2 Connect J1 J2 with 5V power supply Connect power supply trough Multiple Voltage Input Port J3 PIN1 connect the negative polarity of the power supply PIN2 PIN7 connect with 4 5 28V voltage ol system self check and then shows the SN and version
20. d to be free from defects in material and workmanship for a period of one calendar year from date of purchase Your selling dealer is your first point of contact for warranty issues Return postage costs are the responsibility of the user in all cases Submit copy of original receipt with the return Damage due to physical shock dropping on the floor etc inappropriate power supply automotive battery charger etc water moisture and humidity are specifically NOT covered by warranty If there is damage stemming from these causes within the stated warranty period the company will at its option repair or replace the PowerLog for a service charge not greater than 50 of its then current retail list price Date of purchase delivery Dealer Note The manufacturer requires the user to be notified of any change or modification made to this device Enjoy the power V6 24
21. g 6S 4 Alarm Settings Select Alarm setting press lt gt and the screen shows ALARM SETTING Signal Out puls ctivation ALARM OUTPUT Otowsle NO I OToggle NC OHold NO OHold NC ALARM ACTIVATION MDelay Time BY MLogging MPass Through lt A gt or lt W gt to select items press lt e gt button to confirm press lt gt for more than 3 seconds to return See details below lt A gt or lt W gt to select items press lt gt button to confirm and the item will be with press lt gt for more than 3 seconds to confirm the amendment and return When the measured value exceeds the set alarm limit value the alarm triggers sends out signal When the measured value goes back to the normal status if set Toggle the alarm output recovers to normal if set Hold the alarm output remains Toggle NO Toggle mode normal open Toggle NC Toggle mode normal close Hold NO Hold mode normal open Hold NC Hold mode normal close lt A gt or lt W gt to select the items and press lt gt to shift select W L press lt gt for 3 seconds to confirm the amendment and return Delay Time Delay a period of time after powering on and then begins to monitor alarm cases Logging After entering Start logging status it begins to monitor alarm cases Pass Through The measured value is between the normal value range and then it begins to monitor alarm cases For exam
22. lue Reset peak value Press lt A gt lt W gt the Min and Max peak value will be replaced to be the current value 9 Multifunctional Monitor amp Logger Powerlog 65 3 Temperature Monitor TO is constant internal temperature T1 to T3 are external Int Temperature Frota Current Value temperature A ib ieee Vin Value Temp range Ext1 Temperature Ext2 Temperature Ext3 Temperature me mene Vx Value i f NARI SITENE Temp Unit TO 20 C 70 C 4 F 158 F 11 13 55 C 125 C 67 F 257 F lt MENU gt lt A gt lt V gt gt 3 Seconds s Second Reset peak value Press lt W gt lt MENU gt for 3 seconds the peak value will be replaced to be the current value TEMP SENSOR LIST 00000297 e2D6NN TIAE Press lt A gt lt W gt for 3 seconds and enter the screen lt not used gt below Line 2 3 4 in the interface correspond to T1 T2 T3 respectively Press lt A gt lt W gt to choose the needed item and then press lt A gt for 3 seconds to cancel the sensor which becomes lt not used gt when press lt 4 gt it displays T on the right side of the item Press lt A gt lt W gt to alter the sequence and press lt gt to save it Temperature sensor adopts DS18B20 Programmable Resolution 1 Wire Digital Thermometer and the details can refer to http www maxim ic com datasheet index mvp id 2812 The connections to PowerLog as the picture BOTT
23. nd the screen shows PWM ADJ RANGE Pulse width adjustable range settings STEP RIV URE Setting range a 2000 0 u STEPO 5 10000us MIN J0 20000us MAX 0 20000us b PWM Auto Speed Settings Select Auto Speed and press lt gt and the screen shows PWM AUTO SPEED The interval time settings of pulse width increment in PWM Output Step Interval AUTO mode 0 0 ms Setting range 5 0 5000 0ms_ 5 0ms step c PWM Level Settings Select Level and press lt gt and the screen shows PWM SIGNAL LEVEL High Level High Level Ry user set OLow Level a ae 20ms Low Level A user set ea 20ms A6 FA Multifunctional Monitor amp Logger Powerlog 65 Motor KV Meter Select Motor KV Meter press lt gt and the screen shows See SE Press lt A gt for 3 seconds the number of mode begins blinking and then press lt A gt lt W gt to adjust the value Press lt gt to confirm and sA Ta return gt 3 Seconds gt 3 Seconds i Vode JER oo number of Press lt W gt for 3 seconds the number of magnet poles begins Ode WOD CEY 1 a z eet magnet poles blinking and then press lt A gt lt Y gt to adjust the value Press lt gt to av 00953 KV value confirm and return RPM RPE U Ani Motor voltage Setting range MODE 0 1 POLES 2 90 step 2 Motor voltage 0 05 28V e System Settings Select System press lt gt and the screen shows SYSTEM SETTING lt A gt or lt W g
24. nterface MIN 55 0C Ww DIFF BES OT Setting range MAX 54 9C 125C 55C 124 9C 0 1C 180C 8 RPM Alarm Settings Select RPM press lt gt and the screen shows RPM ALARM RPM ALARM applies to the RPM value of Tachometer Monitor MAX 99990 RPMM interface MIN RO RPM MAJA 99990 RPM Setting range MAX 10 99990RMP 0 99980RMP DIFF10 99990RPM 9 Period Alarm Settings Select Period press lt gt and the screen shows PERIOD ALARM PERIOD ALARM applies to the Period of PWM Monitor interface MAX CASTELL OTe ncaa TI MIN ig us M IBD 999990us Setting range MAX 140 999990us MIN 0 999980us DIFF10 999990us 10 Pulse Alarm Settings Select Pulse press lt gt and the screen shows PULSE ALARM PULSE ALARM applies to the Pulse width of PWM Monitor MAX SSG interface MIN ig us v DIFF ERRRIOTRE Setting range MAX 10 999990us MIN 0 999980us DIFF10 999990us 14 Parameter Setup Multifunctional Monitor amp Logger Powerlog 65 Press lt gt for 3 seconds and enter the MAIN MENU Monitor status MAIN MENU Log Files DS PWM Output Motor KV Meter System Calibration lt A gt or lt W gt to select items press lt e gt button to confirm press lt gt for more than 3 seconds to return See details below Log File Management Select Log Files press lt gt and the screen shows LOG FILE Logs OFF Re OLogFilel FILE C
25. ple the normal working current of one machine is 25A set current alarm MIN 20A MAX 30A If powering on PowerLog first and then the machine since C 0 during this period it will trigger MIN alarm If set Pass Through it will avoid this undesirable alarm 18 FA Multifunctional Monitor amp Logger Powerlog 65 5 Log Start Settings Select Log Start press lt and the screen shows LOG START Manual St R Outo Start LOG AUTO START DELAY CURREN 0 TRIMO VOLTAGE ROG s M AM VM Manual Start Press lt W gt for 3 seconds to open close Logging Auto Start Select this item to enter next interface LOG will start automatically according to setting conditions Note by pressing lt Y gt for 3 seconds again to open close Log Auto Start will not be effective and can be effective only by powering again Only when it is M the item and set value will take into effect DELAY Log starts automatically after setting the device of setting time delay for power on CURRENT Log starts automatically when the device detects the absolute value of current is bigger than set value VOLTAGE Log starts automatically when device detects the value of voltage is bigger than the set value Setting range O 9999 Seconds 0 50 0A 0 50 0V 6 Timer Start Select Timer Start press lt e gt and the screen shows TIMER BY CURRENT start lg lViPause vIClear Time vIClear mAh The optional
26. reate File Name LogFilelff The operation to the existing files KURDERE 01230m Logging number the Logs OFF file contains OLogFilel RS LogFilel File Select Ee File Transmit File Empty File Delete LogFilel File Transfer 00100 01229 Total data Transferred data The first item is Logs OFF if it is chosen LOG function is close Press lt A gt for 3 seconds to create new Log files Log file name input method lt A gt to select characters hold it to trigger continuously lt W gt to delete the current character lt gt to confirm the selected character press lt gt for 2 times to confirm the amendment and return press lt gt for 3 seconds to cancel and return lt A gt or lt W gt to select items press lt gt to have a selected item and the item will be with press lt gt for more than 3 seconds to return File Select The selected file is the current log file File Transmit Transmit the selected log file to the USB port it can be received by LogView See details in P20 File Empty Empty all selected log files Press lt gt the screen shows Are you sure you want to empty and press lt gt to confirm and press any other button to cancel File Delete Delete the selected file Press lt gt the screen shows Are you sure you want to delete and press lt gt to confirm and press any other button to cancel 246 FA Multifunctional Monitor
27. rn blades CATE Reset Max RPM gt 3 Seconds Press lt gt lt MENU gt for 3 seconds the peak value will be replaced to be the current value Setting range RPM 0 99999 Light source Blade 1 20 Right measuring methods Tachometer sensor faces directly to the rotary surface and the light source making the distance between 5 to 20cm Note Tachometer sensor is easily interfered by the electronic light source e g fluorescent lamp please keep it far away from these light sources while it is in use PWM Output The regular period of PWM output is 20ms and PWM pulse signal with changeable duty cycle With regard to servo and throttle signal the positive pulse width is altering between 1 to 2ms as picture 20ms Regarding the specific operations please refer to MAIN MENU gt PWM Output P16 Ai Multifunctional Monitor amp Logger Powerlog 6S e Motor KV Meter KV as we use it refers to the RPM constant of a motor it is the number of revolutions per minute that the motor will turn when 1V one Volt is applied with no load attached to the motor Number of Mode0 It works at the 2 wire mode suitable for the KV Mode MODERS UEP OLE SKO daia magnet poles measurement of brushless motor 00953 KV value l Modet It works at the 3 wire mode suitable for the KV RPM Renem Voltage of motor measurement of both brushed and brushless motors Regarding the specific operations please refer to MAIN MENU
28. t to select items press lt gt button to confirm press lt gt Temp Unit a for more than 3 seconds to return Beep Tone See details below POENA Alarm Setting Log Start Timer Start Rec Interval Stat Power Save 1 Temperature Unit Settings Select Temp Unit press lt gt and the screen shows TEMPERATURE UNIT lt A gt or lt W gt to select the items press lt e gt button to confirm and the a item will be with press lt e gt for more than 3 seconds to confirm the OFahrenheit F amendment and return Select Celsius C the temperature unit is Celsius C Select Fahrenheit F the temperature unit is Fahrenheit F 2 Beep Tone Settings Select Beep Tone press lt gt and the screen shows BEEP TONE lt A gt or lt W gt to select the items and press lt gt to shift select W L key Tone ES press lt gt for 3 seconds to confirm the amendment and then return Mint Tone Select Key Tone the buttons tone open MAlarm Tone Select Hint Tone the status tone open Select Alarm Tone the alarm tone open have a Do every 4 seconds 3 LCD Brightness amp Contrast Settings Select LCD Screen press lt gt and the screen shows lt A gt increase lt W gt decrease and press lt gt to shift Brightness Contrast press lt for 3 seconds to confirm the amendment and then return Contrast AF Multifunctional Monitor amp Logger Powerlo
29. to confirm the amendment and return press lt gt for 3 seconds to cancel and return Alarm Parameters Settings Select Alarm amp Trigger press lt gt and the screen shows ALARM SETTING lt A gt or lt W gt to select items press lt gt enter the submenu While Cells Voltag FS press lt gt for 3 seconds to return Pack Voltage See details below Timer Over Current Power Capacity Temperature RPM Period Pulse When setting the alarm items lt A gt or lt W gt to increase decrease value press lt 4 gt and thenM will be blinking press lt A gt or lt W gt to chooseM not choose the alarm item and press lt gt again to shift setting items Only when it is M the item and set value will take into effect Press lt gt for 3 seconds to confirm the amendment and return MAX the upper limit value MIN the lower limit value DIFF the max measuring difference fluctuation range measured MAX value measured Min value 1 Individual Cell Voltage Alarm Settings Select Cells Voltage press lt gt and the screen shows CELL VOLT ALARM applies to the cell voltage in the Cells Monitor CELLS VOLT ALARM MAX ep a interface MIN SEO rd Setting range D Ma 0 05v m MAX 0 06v 28 0v MIN 0 05V 27 99V DIFF 0 01 27 95V 7 Multifunctional Monitor amp Logger Powerlog 6S 2 Pack Voltage Alarm Settings Select Pack Voltage press lt gt and the screen shows PACK VO