Home
A C T 6 0 0 0
Contents
1.
2. z Signal amp Level Meter Frequency range ee Manual tuning resolution Level measurements mode Input range neren Level meter accuracy Noise floor TX OFF 0 5 Frequency Meter sensitivity by Advanced Software 2 ABS shielded for EMI EMC compatibility e RTX connectors IN OUT and TX OUT triple banana jack e polarized connector for external supply e RJ 45 4 connector for headset e USB amp RS232 port for PC connector e USB for Pen drive connector LCD color 320 x 240 pixel 1 4 VGA back lighted and reverse e rechargeable battery pack green 2 x 4 NiMh 1 2 V 2 7A for 8 hours mid of continue operation with battery state indication e external from 16 5 to 26 5 Vdc max 2 5 Ah 150 x 210 x 50 mm 1 5 Kg batteries included operative 0 45 C stock 20 70 C 5 90 no condensing In Out connectors up to 150 Vdc 140 Vpp 1 ppm within the operating temperature 2 ppm year 0 025 within the operating temp 0 025 year Directive 2004 108 CE 89 336 EEC Decree 2007 194 CISPR 11 ISO 14253 and CEI EN 61326 A1 A2 55011 61000 4 2 61000 4 3 61000 4 4 61000 4 6 61000 4 11 e Software update and Results Export using Pen Drive e Results Storage on internal flash memory e Remote control by USB port interface e base band from 20 Hz to 20 kHz e middle band from 20 kHz to 6 MHz e hig
3. lt 15 mA peak safety fold back limited On Hook Break amp Make specs R 120 Q 2 1 100 mA Voffset 4 Vdc Single End Line Tests for line pre qualification With single ACT6000 on open lines 2 or 4 Wire mode One button test automatic sequence Metallics AC DC Voltage DC Insulation AC DC Capacitance End Of Line by TDR Transmissives Wide band Noise local Return Loss Longitudinal Balance Loss FDR Insertion loss amp frequency response estimation Far end Noise estimation SNR prediction ADSL ADSL2 and VDSL 1 2 Bit Rate prediction NEXT Single transmissives tests real time spectral readout Noise Return Loss Longitudinal Balance Loss Next and PSD Automatic End to End Test for line qualification With two ACT6000 Master Slave configuration for Double End Tests 2 or 4 Wire mode Only _Transmissives base and wide band Noise bilateral Return Loss bilateral Longitudinal Balance Loss bilateral LCTL Insertion Loss SNR bilateral ADSL ADSL2 and VDSL Bit Rate evaluation Up amp Down stream NEXT and FEXT Masks for pre configured SELT or DELT line tests e Wide band ISDN HDSL 1p HDSL 2p E1 T1 SHDSL ADSL ADSL2 and VDSL2 12 17 30 Masks for pre configured DELT telephone tests e Base band M1040 M1020 G 712E2 EURO16k EURO32k MIL16k MIL32k Notes by Advanced Software 1 by Advanced Software 2 by adoption of
4. 50 dB up to 6 MHz 2 dB between 0 46 dB up to 30 MHz 3 dB between 0 40 dB e Longitudinal Balance Loss 2 Wires Gnd Test mode see Single frequency or scanner on limited band Frequency range e 200 Hz 6 MHz Measurement accuracy up to 2 MHz 1 dB between 0 60 dB up to 6 MHz 2 dB between 0 56 dB e Single End Insertion Loss included on the Single End Line Testing Measuring Mode readout by FDR technology on High Band Spectral readout Operating Band l a direct 100 kHz 1000 kHz Graphic Extrapolation 20 kHz 6MHz and 30 MHz Operative Impedance 120 Q default balanced line ACCUIACY 2e eeeeeeeeeeeeeeeeeeees 2 1 dB up to 2 2 MHz 2 dB up to 30 MHz Operative limits c c minimum line length 100 meters maximum line length 4 km 0 4 mm wire gauge Event Tests e Micro Interruptions 0 62 base band and wide band Threshold level 0 00 3 20dB 2 kHz Test Tone default or on programmable frequency up to 6 MHz Monitoring time 2 08 4 min 24 ours Events indicators 0 5 Counters 0 3ms gt 1min Event Time Secs with Events Readout cccceeeseeeeeeeeeeeeees Tabular and Time Domain Histogram representation Measure facilities 0 reference tone output from TX connector for loo
5. EBM 30 optional module Supplied Accessories base kit ACT6000 Base Instrument included Nylon Carrying Case with pocket for accessories User Guide English or Italian language as requested AC Power Supply and Battery Charger Line Input 100 220 Vac Output 20 Vdc 1 4A Banana Banana Crocodiles shielded cable 2 30m total length Ground Cable unipolar Banana Crocodile cable Extra cost Accessories and Optional Modules ASW1 Advanced Software 1 see the above description ASW2 Advanced Software 2 to be develop it will include the End to End Master Slave line test PC utility programs to SELT Remote Control SW Update Capture Screen Export amp Read Saved Tests Masks Editor etc ACT 11 POTS Module Subscriber Simulator Module for POTS for signalling tests ACT 12 DMM Module Digital Multimeter Module for metallic tests ACT 13 EBM30 Module Extension Band Module for 30 MHz operation ACT 14 USB Pen Drive 4 GB ACT 15 Probes to perform Medium amp High Band PSD measurement on lines fed ALT 05 Headset with 2m cable and RJ 45 4 connector ALT 09 Resistive Termination Set 100 120 135 150 and 600 ALT 16 Banana to BNC Adapter ATEN S r l Via dei Lavoratori 180 04100 LATINA ITALY Tel 89 0773 240696 Fax 39 0773 240676 e mail sales aten it Web www aten it Aten S r l reserves the right to change this preliminary specifications without prior notice
6. Advanced Communication Tester SINE SIGNAL amp NOISE GENERATOR SELECTIVE LEVEL METER CROSS TALK METER SPECTRUM amp NETWORK ANALYZER LONGITUDINAL BALANCE amp RETURN LOSS METER MI CROI NTERRUPTION amp IMPULSIVE NOISE METER VOLTAGE RESISTANCE CAPACITANCE METER TDR amp RESISTANCE FAULT LOCATOR POTS DEVICE SIMULATOR ALL ON THE PALM OF YOUR HAND This new instrument combining various kinds of transmission metallic and special tests may be considered up to today the most advanced Test Set for qualifying and maintenance of advanced transmission systems and copper pairs used for various telecommunication services ePOTS elSDN eT1 eE1l eHDSL 1 2P eSHDSL eADSL eADSL2 eVDSL2 ERGONOMIC CHARACTERISTICS One of ACT6000 most interesting features is the colour LCD high i resolution graphic display a real window on the most advanced measurements world The alphanumeric keypad as well as the function keys grant to the instrument a high operating level Moreover don t miss to notice that due to its accurate and intuitive Human Machine and Graphics User Interface this instrument doesn t need the help of the users manual if not to arrange and carry out unusual measurements and or settings DATA COMMUNICATION CHANNELS amp COPPER PAIRS QUALIFICATION CERTIFICATION One ACT6000 can perform easy and quick Single End Line Tests or very accurate End to End Line Tests if coupled with another AC
7. BW High band measure method PAN esuswa cies eaa i Level reading mode f Measurement mode nesen Input range 0 DS Noise MOOF acneea I S Resolution marker lev freq Network Analyzer 06 e base band 150 200 600 and gt 10 kQ e middle band 100 110 120 135 150 Q e high band 100 Q 50 and 75 Q by Banana BNC adapter e base band psophometric C Message 0 3 3 4 kHz 0 02 3 4 kHz 0 3 6 0 kHz 0 02 6 0 kHz 0 3 15 0 kHz 0 02 15 0 kHz 0 3 20 0 kHz 20 20 0 kHz 20 0 kHz flat e middle high band E F G and VDSL 2 12 17 and 30 e base band 200 Hz 20 kHz pass band and notch for S N D dB and test 10 Hz fo lt 200 Hz 5 fo gt 200Hz fo lt 4 kHz 200 Hz fo gt 4 kHz selective for telegr chann 120 240 360 480 Hz e high band 20 kHz 6 or 30 MHz selective 25 100 200 400 Hz and 1 74 3 1 4 0 8 0 16 0 kHz e from 200 Hz to 6 MHz two band base version e up to 30 MHz by optional module EBM 30 e base band 150 200 600 and gt 10 kQ balance e middle band 100 110 120 135 150 Q e high band 100 Q 50 and 75 Q by Banana BNC optional adapter 200 25000 Hz by FFT analyzer Kaiser window 6250 12500 and 25000 Hz 250 pixel 10 div 625 1 250 2 500 Hz div 192 pixel 8 div 1 2 3 20 dB div 50 100 200 Hz other resolutions are interpolated 1 kHz to 6 30 MH
8. T6000 The wide kind of measurements of the ACT6000 allows the qualification and certification on various communication carriers and copper pairs used for digital streams with a frequency occupancy up to 6 MHz or 30 MHz optional moreover the instrument can automatically extrapolate the ADSL and VDSL maximum expected data rate of the copper line under test COPPER PAIRS DIAGNOSTIC amp FAULTS FINDING LOCATION ACT6000 can be configured for high troubleshooting mission by special functions and internal optional modules The complete adoption of these modules allows the simple and fast finding and localization of anomalies and or faults on the copper line and communication systems ACT6000 TECHNICAL CHARACTERISTICS General OF Connections cccceceeeeeeeeeeees ky 5h ae ee i Power supply internal Dimensions and Weight Temperature range Humidity range eeee Overvoltage Protection Reference Frequency accuracy Reference Level accuracy CE mark EMC sssienswsdiviereccuunt Special Features and Setup s Signal Generator Sine output frequency range Frequency Resolution i Frequency setup mode Output level cceeeeeeees Output level accuracy 5 Balanced output impedances Unbalanced output impedances White Noise Generator
9. UIACY cceeeeeeeeeeeeeeeeeeeeeeeee T 1 Of reading 1 nF C lt 500 nF 5 of reading 1 digit C gt 500 nF and lt 3000 nF LINE LENGTH BY CAPACITANCE Line length estimation as function of measured capacitance Line Capacitance setup 10 0 to 300 0 pF Length Unit Range Resolution Accuracy 1 to 99999 Units m or ft 1 units as derived from measured capacitance RFL Resistance Fault Locator Loop resistance 000 4 KQ maximum Fault resistance from 100 Q to 20 MQ maximum Accuracy of RTF 1M 0 1 of Loop resistance FROAG OUTS 2ei ce8ectveceneeaserchereeetens graphic representation and action help RBAL Resistance Balancement starting from 5 Q Readout sect cnenens graphic representation and action help MULTI GAUGES facilities to set 3 sectors of multi gauges lines to compute the line length or fault localization by loop resistance line insulation e POTS Subscriber Simulator by optional module installed on DMM module Dial Encodet c cccseeeeees Pulse programmable on duration ratio default 100 ms 40 60 DTMF std tones programmable on Level Duration Inter tone Ring Detect Range amp Meas Level 10 90 Vrms Frequency 15 70 Hz Ring Detector AC Load R7310 Q 2 in series 940nF 10 capacitor Ring current self limitation
10. e selection from 10 to 5000 ns IN OUT impedance 100 110 120 135 150 Q balanced TGC automatic gain control 0 6 dB km Propagation velocity PVF 0 300 to 0 999 o PV 90 to 300 m us e Digital Multimeter DC AC by DMM optional module Measuring mode 00000 automatic between a b a c Gnd b c Gnd and reverse DC Voltage Range Accuracy 0 140 Vdc lt 2 of reading 1 digit AC Voltage Range Accuracy 0 100 Vrms lt 2 of reading 1 digit up to 1kHz Resistance Insulation Test Voltage eee E 100 Vdc with current limitation 1mA max Range Accuracy 5Q0 16GQ lt 2 of reading digit LINE LENGTH BY LOOP RESISTANCE Line length evaluation as function of measured resistance Line Gauges setting from 0 4 to 0 9 mm or from AWG 26 to AWG 19 Line Resistance correction from 1 01 to 1 60 x standard copper resistance Line Temperature setting set from 20 60 C Range Resolution 0 0 to 99 999 kUnits meters or feet 1 units DC CAPACITANCE time of DC discharge method Test Voltage cece S 100 Vdc Range Accuracy gt gt 10 nF 10 uF lt 5 of reading 1 digit AC CAPACITANCE by capacitive bridge Measuring mode by 1 kHz tone 1 1 Vpp between a b wires Range Resolution 0 1 to 3000 nF 0 1 nF ACC
11. h band optional from 0 02 to 30 MHz 1 Hz up to 9 999999 MHz 10 Hz over 10 0 MHz manual on single frequency and steps mode on programmable band steps 60 20 dBm 150 Q 0 1 dB steps 0 2 dB from 400 Hz to 20 kHz 600 Q 0 2 dB up to 2 MHz 0 3 dB up to 6 MHz 100 Q 0 5 dB up to 30 MHz 100 Q e base band 150 200 and 600 Q e middle band 100 110 120 135 150 and 1350 Q e high band 100 Q 50 and 75 Q by Banana BNC optional adapter 1 kHz 6 MHz 74 144 dBm Hz 0 1 dB steps from 20 Hz to 6 MHz two bands base version up to a 30 MHz with EBM 30 optional module 1 Hz up to 9 999999 MHz 10 Hz over 10 0 MHz absolute dBm or dBV or Volt or relative dBr 120 12 dBm 100 Q 0 1 dB Resolution 0 2 dB from 400 Hz to 20 kHz 600 Q 0 2 dB up to 2 MHz 0 3 dB up to 6 MHz 100 Q 0 5 dB up to 30 MHz 100 Q lt 140 dBm Hz lt 40 dBm on wide band or selective mode Input impedances balanced f Input impedances unbalanced Noise filterS cccceeeeee Selective filters notch Spectrum and Network Analyzer Frequency range e Input impedances balanced i Input impedances unbalanced Base band 0 SPAN nnana ss eae Resolution horizz vertical Resolution BW Middle band 000 00 SPAN cise E N Resolution horizz vertical Resolution
12. pback tests e Impulsive Noise O 71 base band and wide band Threshold level 008 0 60 dBm Base band BW filters 200 12 000 Hz Flat 600 3 000 Hz 300 500 Hz DSL bands PB filters 20 kHz 6 30 MHz some sectors of E F G and VDSL filter Monitoring time 0 4 min 24 hours Events indicators 1 Event Counter Event Time Ratio Secs with Events a FREAD OU Es sxx reenit Tabular and Time Domain Histogram representation Special Measurements e Line Immunity by White Noise injection Output level range 70 144 dBm Hz Zref 1000 0 1 dB Resolution Output impedance 100 120 135 150 and 1350 Q balanced Bandwidth eeeeeees 1 kHz 6 MHz e TDR Fault locator Distance ranges 90 180 450 900 1800 3600 7200 m 0 600 PVF ZOOME AA 23 cae highest A vertical 8 77 dB horizontal 1x 2x 4x Distance resolution by marker minimum range about 0 4 meters or 1 feet maximum range about 40 meters or 100 feet Operative mode 6060 single line 2 wires Crosstalk 4 Wire Differential by relative comparison with other line Monitoring to events localization by Peak mode Sample amp Hold Pulse output level 6 short and long 2 2 Vpp Boost 5 5 Vpp Pulse length 000e ee automatic on rang
13. z by Digital SSB quad conversion 30 ranges from 10 to 8000 kHz 10 per decade 250 pixel 10 div 1 2 4 8 16 800 kHz div 192 pixel 8 div 1 20 dB div 0 2 0 5 1 2 5 8 kHz other resolutions are Interpol Double conversion receiver by int optional module 0 12 0 18 and 0 30 MHz absolute dBm dBm Hz dBV and dBr relative normal peak max mean or min value 2 Wires for Return Loss measurement 2 Wires for Longitudinal Balancement measurement and 4 Wires 100 12 dBm 100 Q 140 dBm Hz 100 Q high band with 16 kHz filter 0 1 dB as selected resolution BW by tracking generator or single freq in 2 4 wires mode Mix measurements Generator Meter and Network Analyzer e Cross Talk j a Test mode EEE Frequency range 00 Measurement accuracy Intrinsic crosstalk Near End Single End and Far End End to End single frequency or scanner on limited band 200 Hz 6 MHz up to 30 MHz EBM 30 opt module up to 2 MHz 1 dB between 0 90 dB up to 6 MHz 2 dB between 0 86 dB up to 30 MHz 3 dB between 0 80 dB lt 90 dB with precise resistive load e Return Loss 2 wires Test MOd6 xa iver cede single frequency or scanner on limited band Frequency range cc 200 Hz 6 MHz up to 30 MHz EBM 30 opt module Measurement accuracy up to 2 MHz 1 dB between 0
Download Pdf Manuals
Related Search
Related Contents
Page 1 Page 2 @grama @ät â ® 63%@ @mi Page 3 Page 4 Page 取扱説明書 - Fujitsu manual server - Linkman Audioの世界 Gigabyte GA-H61M-WW (rev. 1.0) Mode d`emploi User Manual - Heatpressuk Comment une petite entreprise innovante peut Hacer Sonar Patrones Version PDF SOU A SINGULAR NIKON 1 Copyright © All rights reserved.