Home

NP-880S - IVC Displays, Inc.

image

Contents

1. eo Touch Screen Calibrate mode In this mode when you power on the NP 880S the screen will display a sign at the efully press and briefly hold stylus on the center of the targ center of the screen Use a stylus or Repeat as the target moves around the screen finger to push the center of the until it moves The moves to T upper left lower left lower right and upper right corners When all five are done the will disappear The Touch Screen parameter will store at Flash Rom Oo Boot Loader mode Load new Windows CE image file If the NP 880S already load the CE image with boot loader Set the DIP SW3 ON then power ON into boot loader mode Refer the load Win CE image document 2 4 LED Indictors Communication Red Ethernet communication active CPU CPU Green When the unit power on the CPU LED will ON after CPU boot up it will turn OFF Normal is OFF If the CPU LED still ON that mean CPU boot up fail When download CE image the CPU LED will slowly flash Power Orange System power LED indicator 17 2 5 CE Requirements EU directives that apply to the NP 880S Series O EMC Directive 89 336 EEC 92 31 EEC 93 68 EEC electromagnetic emissions and immunity O Machinery Directive 89 392 EEC 91 368 EEC 93 44 EEC 93 68 EEC machine safety O NP 880S products will be CE marked to indicate compliance with the EMC Directive The NP 880S Serie
2. A 64 si 2 2 Power Connections Make sure that all local and national electrical standards are met when the installing the unit Contact your local authorities to determine which codes apply FUSE 1A 20 OV FG 10 2 2 1 Power Requirements Power Fusing Requirements Caution High Voltage Caution Emergency Stop Caution Supply Voltage Condition Caution Wire Routing Connection The NP 880S can be powered by DC power only The specified voltage range is 25 5 Volts DC This insures compatibility with most controller DC systems The power conditioning circuitry inside the unit is accomplished by a switching power supply The peak starting current can be as high as 700mA If the display does not come on within 2 seconds of power up remove power An internal fuse will prevent damage if the polarity of the DC power is incorrect Check wiring to insure proper connections and try to power up again An Internal fuse will prevent damage for over voltage condition however it isn t guaranteed DC voltage sources should provide proper isolation from main AC power and similar hazards A Hard wired EMERGENCY STOP should be fitted in any system using an NP 880S to comply with ICS Safety Recommendations Do not power the NP 880S and inductive DC loads or input circuitry to the controller with the same power supply Note The 24 VDC output from some controller
3. though the source code may not be changed at all The following development tools must be installed on the PC O Microsoft eMbedded Visual C 4 0 O Microsoft eMbedded Visual C 4 0 Service Pack 1 EP931X SDK 3 4 1 Microsoft eMbedded Visual C 4 0 System Requirements To use Microsoft eMbedded Visual C 4 0 you need the following A desktop computer with a Pentium II class processor 450 MHz or faster o Microsoft Windows 2000 Professional SP2 Microsoft Window 2000 Server SP2 or Microsoft Windows XP Professional 6 96 MB 128 MB recommended memory for Windows 2000 Professional or Windows XP Professional 192 MB 256 MB recommended memory for Windows 2000 Server e CD ROM drive required O VGA or higher resolution monitor A Super VGA 800 x 600 or larger monitor is recommended Oo Mouse or compatible pointing device o 200 MB hard disk space 32 3 4 2 EP3915 SDK The EP3915 SDK provides developers with access to an extensive set of functions that are os to the NP 880S hardware Step sting x sa TO Download the EP391X_SDK msi file Double click the file s name to start the Setup Wizard The installer will be prompted Y ep931x Setup for acceptance of a license Welcome to the ep931x Setup Wizard agreement The Setup Wizard will install ep931x on your computer Click it the Seh in Wizard Follo win g that the SDK should Next to contin e nr Cancel Fo exit the install itself automatically on
4. Pin Designations Pin assignment of the 9 Pin Male SUB D COMI RS 485 COM3 RS 485 and COM3 RS 232 Port COM1 RS 485 COM3 RS 485 me Symbol Comi Comi Com3 Com3 1485 2w RS485 4w 485 1232 COM3 RS 232 K5485 2w R5485 4w RS485 R5232 COM1 RS 485 connect COMI WG age RS 485 2 wire Device RS 485 2 wire Device 9P D SUB Female COM1 RS 485 connect COMS Gs Am RS 485 4 wire Device RS 485 4 wire Device 9P D SUB Female Tx ae te el WE Rx RS485 Receive Rx RS485 Receive 15 2 3 3 USB Master ports The USB Master ports can connect USB mouse and USB keyboard The USB Master ports support USB 2 0 full speed host 12Mbps This ports support USB Mass storage device But the USB hard disk must use external power RESET Dir SW COMI RS485 2 4W COM3 COMS RS232 COMI RS232 2 3 4 44Pin IDE Interface The 44 Pin IDE Interface support D O M Disk On Module and 2 5 hard disk The 2 5 hard disk need a female to female 44Pin cable Please turn off the power before plug or pull the D O M or 2 5 hard disk MT608T has open 10 100 Base T Ethernet port There are two LED indicators on the Ethernet port Orange LED LAN Link status Green LED Active status 16 2 3 6 Dip Switch N a tas tar be Touch Screen Calibrate mode oF fox or lorrpeme 1233 Orr ke ow Orr BootLosermode EE
5. DELER WO Do 33 SAP a sd PC o 5 II erin tena E TA 34 Copyright This document is copyrighted March 2006 by IVC Displays Inc All rights are reserved IVC Displays Inc reserved the right to make improvements to the products described in this manual at any time Specifications are thus subject to change without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of IVC Displays Inc Information provided in this manual is intended to be accurate and reliable However IVC Displays Inc assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use COM CPI PWR Microsoft Windows CE net safety Instructions Overview This section states the safety instructions which must be followed when installing operating and servicing the NP 880S If neglected physical injury and death may follow or damage may occur to controller and related equipment The material in this chapter must be studied before attempting any work on or with the unit Warnings and Notes This manual distinguishes safety instructions Warnings are used to inform of conditions which can if proper steps are not taken lead to a serious fault condition physical injury or death Notes are used when the reader is required to pay special attention or when there is additional information available
6. RAS server connection with this desktop computer Status Network is available Status icon i Show status ican in Taskbar Cancel Help 30 NP 880S Run Windows repllog exe remote EH Type the name of a program folder or document aid Windows will open it for you Cancel Browse Choose Network Connection And choose PC s name Click Connect button The NP 880S connect to PC via EE Ethernet Connected up to date ee Disconnect when complete Disconnect 3 3 3 Web browser The NP 880S built in Windows CE OS includes Microsoft Pocket Internet Explorer It can be used to browse web pages on World Wide Web via LAN or dial up connection File Edit View Go Favorites aja al 2 Lk Address fle windows default htrm Welcome to Microsoft Pocket Internet Explorer al e gr co Y Windows CE 1996 2002 Microsoft Corporation All rights reserved Terms of use Asta Jl 3 windows ce AZ 6 11 PM 31 3 4 Application program development The NP 880S is bundled with built in Windows CE operating system In real applications users need to execute various applications programs on it However unlike its other family the Windows CE is a hardware dependent operating system That is to say Windows CE application programs are only portable in the source code level Users must rebuild the runtime file for a different Windows CE platform even
7. O Rating 250VAC 1A Oo Size 5x20mm LCD Display Oo Displaytype TFT color LCD Oo Display size diagonal 8 Oo Max colors 65536 O Resolution 640 x 480 O Pixel pitch HxV mm 0 2535 x 0 2535 O Viewing angle 56 65 65 65 T B R L Luminance cd m2 400 Oo Storage temperature C 25 70 O Operating temperature C 0 45 Backlight CCFLx1 O Contrast ratio 250 1 Touch screen Type 4 wire analog resistive Resolution continuous Light transmission above 80 Life 1 million activation minimal Environmental Specifications Operating temperature 0 45 C 32 113 F Relative humidity 10 90 40 C non condensing Shock operation 10 to 25Hz X Y Z direction 2G 30minutes EMI Complies FCC class A CE Complies with EN50081 2 and EN50082 2 standards Front panel meets NEMA4 IP65 Chapter 2 Installation Instructions 2 1 Mounting Instructions 2 1 1 Location Considerations Care should be taken when locating equipment behind the unit to ensure that AC power wiring PLC output modules contactors starters and relays and any other source of electrical interference are located away from the back of the unit Particular note should be taken to the position of variable speed drives and switching power supplies Their input and load cables should be screened to a central star earth point 2 1 2 Making a NEMA 4 Mounting Panel Details The unit can be mounted into panels with a depth of 4 105mm It is
8. ctiveSync installed on the host PC Click the 9 Microsoft ActiveSync Connection y Mier Tools Help Settings PEN Synchronize e y A i ey ee S Dalete Partnership Get Connected Allow serial cable or Gon AB EH an Selime infrared connection to El Click Get Connected to connect your mobile device to this this COM port Zug computer Status Wailing for device to connect Get Connected iw Allow senal cable or infrared connection to this COM port COM Status COM port is available Connect the NP 880S Coml RS232 and PC RS232 by the RS232 ActiveSync cable 28 ActiveSync cable PC COMI CN5 COM RS232 9P D SUB Female 9P D SUB Female 1 4 6 short Windows repllog exe Follow the onscreen instructions to Es establish a partnership and Set Up a Partnership synchronize your NP 8 80 S with Before you can synchronize information between your mobile device and this computer you must set up a partnership between them yo ur desktop computer Would you like to set up a partnership Set up a partnership so that can synchronize information between my device and this computer C No don t want to synchronize information Set up my device as a quest so that can copy or move information between my device and this computer Now you can synchronize the 3 Microsoft ActiveSync a A File View Tools Help information between the NP 880S o O and h
9. NP 880S RISC based operator interface terminal with 8 flat panel display User s Manual COM CPI PWR e Recycle Bin A A Microsoft Windows CE net DIDI NETE OR POPE PE O A a E A a ak BEG na aa ga a ka 4 EE 5 Chapter lc Keen e Tee EE 6 1 1 os E 6 EE 6 Chapter 2 Installation INSU CliOMns wi SS ee 9 2 A Mount DE tele EE 9 2 ll MOC AMON OASIS 9 2 1 2 Making a NEMA 4 Mounting c0ccccceccccseeccasecceseeccesccseaceseaaeeees 9 2 1 3 Environmental Consderatnons een eena nana nana nenen a anana n eee 10 22 Power CODEC HONS ee 10 2 2 Power REQUIRGINCING E 11 22 2 GrOUnGING EIERE EE 12 22 Ee ee EE 12 22A Safety GUI NG atra 12 2 3 Communications Connections a 14 2231 Eomector CON TIRS232 Lu ES 14 2 3 2 Connector COM RS485 COM3 RS 485 and COM3 RS 232 15 LAS SAS PONS een eid aes 16 2 3 4 44 Pin IDE Interface ota 16 AR AP N T E 16 e IN Na aa a aa aja a Aga an E bah aa a aaa 17 ZA LP EE ICE A E 17 ZO KEGI GA ee 18 200 VES tandane ME 18 Dih DIMENSIONS OL NPS 80 EE 19 Chapter 3 Windows CE NE T 0 ia 20 SIMON sasa aa ts 20 GE 20 PALDO KyO ON EE 20 Deli 2 SY AS A o o E 5 21 32 NOR Flasi EE 24 STEE 25 3 2 3 Remote Desktop ee EE 25 NES US EE 2I 3 3 1 Networking Via E TEE 24 EAN e e PR EII gk aga a a a a E 28 Dod WED tee 31 3 4 Application program development oocccocccnnnccnnnncnnononnnoncnnncnnnnncnnnnnnnonnnnnns 32 3 4 1 Microsoft eMbedded Visual CA 32
10. RISC kernel the CIRRUS LOGIC EP9135 200MHz processor design with a memory management unit MMU that supports Windows CE The ARM920T s 32 bit microcontroller architecture with a five stage pipeline delivers impressive performance at very low power The EP9315 includes a hardware graphics acceleration engine that improves graphic performance by handling block copy block fill and hardware line draw operations The graphics accelerator is used in the system to off load graphics operations from the processor Features Built in flash memory and Windows CE OS inside All in one platform the CPU DRAM and Windows CE are integrated Low power consumption and Fan less NEMA 4 IP65 compliant front panel One CompactFlash slot Audio Ethernet port 10 100Base T 44 pin IDE Interface 1 2 Specifications O Construction plastic molding housing Display 8 640x480 65536 Color TFT LCD CPU and core logic CIRRUS LOGIC EP9315 200MHz ARM920T core processor DRAM 64 MB on board Storage 32 MB flash memory on board 1 CompactFlash card slot 44 pin IDE Interface o I O 3 serial ports o Coml RS 232 RS 485 2w 4w o Com2 RS 232 o Com3 RS 232 RS 485 2w o 1 Ethernet port 10 100Base T 3 USB 2 0 full speed host 12Mbps O Sound output 20 bits Stereo output O Microphone In O RTC Built in Power input 24 VDC 440mA maximum O Dimension W x Hx D 240 x 179 x 50mm o Weight Approx 1 3kg FUSE o BUSSMANN Fast Acting Glass Tube
11. ates Remote lt Select the ways that this computer can be used from another location Remote Assistance Allow Remote Assistance invitations to be sent from this computer Leam more about Remote Assistance Advanced Remote Desktop ho users to connect remotely to this computer Full computer name Leam more about Remote Desktop Select Remote Users E To create a new Remote Desktop Connection 1 Open Remote Desktop Connection 2 In Computer type the computer name for your computer running Windows XP Professional that has Remote Desktop enabled and for which you have Remote Desktop permissions 3 Click Connect The Log On to Windows dialog box appears In the Log On to Windows dialog box type your user name password and domain if required and then click OK The Remote Desktop window will open and you will see the desktop settings files and programs that are on your office computer Your office computer will remain locked Nobody will be able to work at your office computer without a password nor will anyone see the work you are doing on your office computer remotely Note To change your connection settings such as screen size automatic logon information and performance options click Options before you connect 26 3 3 NP 880S Networking 3 3 1 Networking via Ethernet The NP 880S is equipped with a 10 100Base T Ethernet controller To utilize it change the device na
12. d be aware that this potential safety hazard exists and take appropriate precautions Although the specific design steps depend on your particular application the following precautions generally apply to installation of solid state programmable control devices In addition these precautions conform to the guidelines for installation of Controllers as recommended in the NEMA ICS 3 304 Control Standards Programming Considerations To conform with ICS Safety Recommendations checks should be placed in the controller to ensure that all writable registers that control critical parts of plant or machinery have limit checks built into the program with an out of limit safe shut down procedure to ensure safety of personnel ICS 3 304 81 Safety Recommendations Consideration should be given to the use of an emergency stop function which 15 independent of the programmable controller Where the operator is exposed to the machinery such as in loading or unloading a machine tool or where the machine cycles automatically consideration should be given to the use of an electromechanical override or other redundant means independent of the programmable controller for starting and interrupting the cycle If provision is required for changing programs while the equipment is in operation consideration should be given to the use of locks or other means of assuring that only authorized personnel can make such changes These recommendations are intended as sa
13. end to end development environment Windows CE NET contains everything you need to create a custom Windows CE based device that requires rich networking hard real time and a small footprint as well as rich multimedia and Web browsing capabilities e Recycle Bin E Internet A Explorer Microsoft o Windows CE net Remote Desktop 3 2 Utilities There are several useful utilities built in the standard Windows CE OS of NP 880S 3 2 1 Soft Keyboard The NP 880S is dedicated to the small sized operator interface It is often inconvenient for users to attach a keyboard to such small machine Thus a software keyboard is 20 embedded in the standard Windows CE OS Upon boot up a small keyboard icon will appear on the status bar Tap this icon by the stylus to activate hide this Soft keyboard Input Panel Esc 1 213 4 5 6 7 8 9 0 Tab a w j ej r tjyjujilojplt Cp alelolrlalni ll shirt 2 x ci b nim 7 cel l TA te gt Ge AL 2 04 PM 3 2 2 System Settings NP 880S provides an integrated utility for users to make basic setting of the machine Touch Screen settings The touch screen calibration can be executed from the Control Panel Launch the System Settings System settings OK E Control Panel Touch Screen settings LCD Settings lr EA Tapping the Calibrate b apping t e a 1 rate utton Carefully press and briefly hold stylus on the cent
14. er of the target Repeat as the target moves around the screen Press the Esc key to cancel The screen will display a sign at the center of the screen Use a stylus or finger to push the pe eee center of the until it moves The moves to upper left NG lower left lower right and an upper right corners When all five are done the will disappear The Touch Screen parameter will store at Flash Rom Backlight System settings Turn off backlight if device not used for LCD Settings page of the cecp provides the function to turn off the LCD backlight and thus elongates the period of service For example if the user wants the backlight turned off automatically after 10 minutes when the device was no longer used The user must select 10 minutes in the put down box and then press OK button Then the screen save function is enabled Once the backlight was turned off events or perturbations from the touch screen can turn it on On the other hand if users want to disable the screen save function select Never and press OK button 22 MAC address System settings LED Settings l0 Oc 26 00 10 65 n o n sl Ll a The MAC address page the block shows the network MAC address Save Tap the Save registry button will save the System settings registry data to the NORFlash folder The next time the NP 880S
15. es is to make a shortcut and copy it to NORFlash StartUp A shortcut can execute a program with Parameters Follow the following procedure to create the shortcut Ink file A Ink file is a text file that contains the command line for the linked target which may be enclosed in double quotation marks along with the length of that command line Optionally you can also pass parameters into the linked target By default a Ink file uses the following format number of ASCII characters after pound sign command line optional parameters For example to start MyApp exe and pass two optional parameters into the application a sample MyApp Ink file contains the following 40 Windows MyApp exe parameter parameter2 3 2 5 Remote Desktop Connection Use Remote Desktop Connection you can remotely control your computer H ern ote Desktop To use Remote Desktop you need the following Windows XP Professional installed on your office computer or whichever computer you plan to operate remotely This computer is known as the host You must first enable the Remote Desktop feature on your office computer so that you can control it remotely from another computer You must be logged on as an administrator or a member of the Administrators group to enable Remote Desktop on your Windows XP Professional based computer 20 system Properties General Computer Name Hardware Advanced System Restore Automatic Upd
16. feguards against the failure of critical components and the effects of such failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation o The ICS 3 304 81 Safety Recommendations are reproduced by permission of the National Electrical Manufacturers Association from NEMA ICS 3 304 13 2 3 Communications Connections The ports as you look at the back of the case are the ports for connecting to a PLC or some external device Controller Connectors Cable Different cables are required for various devices Requirements Caution Restrict cable length to less than 500 150m for RS485 422 devices and 50 15m for RS232 devices to avoid communications problems The COM light on the front of the NP 880S will turn on with each communication Shielded cable must be used for long lengths or cables run in an electrically noisy environment Do not run cables next to AC power lines or near sources of electrical noise Be sure that the cable ends have been inserted all of the way into mating connectors and are secure 2 3 1 Connector COM 1 RS232 Pin Designations Pin assignment of the 9 Pin Male SUB D COM1 RS 232 and COM2 RS 232 Port COM1 RS 232 COM RS232 2 ned Jess sopo emo a m SS s op SignatGrownd s eo eann DREES s Jet cteartosendimp o sowa 14 2 3 2 Connector COM1 RS485 COM3 RS 485 and COM3 RS 232
17. from the power supply return point to the central star earth point Ground conductors should be as short and as large in size as possible The conductors must always be large enough to carry the maximum short circuit current of the path being considered Ground conductors should be connected to a tree from a central star earth ground point This ensures that no ground conductor carries current from any other branch 2 2 3 CE Requirements To make an NP 880S comply with EMC directives and to reduce susceptibility to electrical interference a separate 14 AWG ground wire should be taken to the chassis ground terminal of the power connector This ground connection should be run directly to the central star earth connection point as recommended in most Installation Instructions 2 2 4 Safety Guidelines This section presents recommended installation practices and procedures Since no two applications are identical these recommendations should be considered as guidelines Hardware Considerations WARNING The system designer should be aware that devices in Controller systems could fail and thereby create an unsafe condition Furthermore electrical interference in an operator interface such 12 as an NP 880S can lead to equipment start up which could result in property damage and or physical injury to the equipment operator If you or your company use any programmable control systems that require an operator or attendant you shoul
18. lor printer PCL Laser HP LaserJet printer Port e COMI 57600 COM1 57600 COM1 9600 via COM 1 COMI 9600 RS232 connect to printer IRDA LET IRDA NP 880S doesn t support IRDA connect LPT1 When connect a USB printer to NP 880S s USB Host port will appear this item Network via network connect to a shared printer 34 Net Path MW MP Cname PrinterName When select Network will enable the Net Path field Key in the computer name and shared printer name Paper Size Paper Size Draft Mode a Draft Mode Desktop PC shares the printer ddress Ki Printers and Faxes Adobe POF M3 A Ready Printer Tasks Add a printer Setup Faxing hp LaserJet 3350 Fax a Ready Ser Aien hp LaserJet 3380 PS y B 2 Troubleshaot printing SA Ready led Get help with printing K Other Places 2 hp LaserJet 3380 PS Properties General Sharing Porte Advanced Security d Dewce Settings About S You can share this printer with other users on your network To A enable charingfor this printer click Share this pinter C Do not share this sinter Share this printer Share name Eu Drivers lf this printer is shared with users running different versions of Windows you may want to install additional divers so that the users do not have to tind the print diver when they connect to the shared printer 35
19. me when the NP 8805 is first turned on se Lu E Control Panel Click Start Settings Control Panel 2 Double click Network and Dial up Connections Find the default device name Change it to a unique one depending on the plan of individual LANs 5 If the NP 880S is a node of a LAN e ee Network and Dial up Eb A LAN90001 LAN9000 Network Compatible Adapter Settings IP Address Name Servers An IP address can be automatically assigned to this computer If your network does not automatically assign IP addresses ask your network administrator for an address and then type it in the space provided Specify an IP address IP Address LETT Subnet Mask LETT Default Gateway LETT with fixed IP server please consult with MIS to get specific IP address Click Start Settings Control Panel Double click Network and Dial up Connections and update the IP 4 If the NP 880S is a node of a LAN with DHCP servers it is now available address 3 6 Use the cecp utility Save registry System settings LCD Settings MAC address Save Save registry to save this changed 271 3 3 2 ActivSync The NP 880S uses the COM RS232 connect the PC Windows CE NEI 4 2 please use ActiveSync version 3 8 0 Windows CE NET 5 0 please use ActiveSync version 4 1 0 1 Make sure the Microsoft ActiveSync Microsoft service 1s properly ees
20. on the subject Notes are less crucial than warnings but should not be disregarded Warnings Readers are informed of situations that can result in serious physical injury and or serious damage to equipment with the symbol shown to the left A Warning symbol indicates that the reader should pay special attention to the accompanying text Precautionary steps should be taken to insure that the installation is in compliance with warnings Warnings include hazardous conditions that could cause personal injury or equipment damage if care 1s not taken The text next to this symbol describes ways to avoid the danger Warnings Dangerous Voltage Warnings Warns of situations in which high voltage can cause physical injury and or damage equipment General warning Warns of situations which can cause physical injury and or damage equipment by means other than electrical Electrostatic Discharge Warning Warns of situations in which an electrostatic discharge can damage equipment Readers are notified of the need for special attention or additional in formation available on the subject with the following symbols CAUTION Aims to draw special attention to it Note Note gives additional information or points out more information available on the subject Chapter 1 Introduction 1 1 Introduction The MT608 is a miniature and compact platform that has no redundant functions It is designed for small sized operator interface market Its
21. ost computer with Syns Stop Detaile Explore Options Guest ActiveSync Connected 29 Use Ethernet connect to PC ActiveSync Only ActiveSync 3 8 1 New Partnership 1 Before you begin Set up a partnership between your Set Up a Partnership device and desktop computer Before pou can synchronize Information between your mobile device and this computer you must setup a u sing RS 2 3 pi connection partnership between them Would you like to set up a partnership Setup a partnership so that can synchronize Information between mu device and this computer O No don t want to synchronize information Set up my device az a quest so that can copy or move Information between my device and this computer Follow the onscreen System settings instructions to establish a partnership and synchronize your NP 880S with your desktop computer Enable a network Ethernet Connechon Setting connection in ActiveS ync y R m Click Get Connected to connect pour mobile device to this 1 On the File menu click Ta computer Connection Settings Status Wailing for device to connect Get Connected 2 Select Allow network z l Ethernet and Remote Access Iw Allow serial cable or infrared connection to this COM part Service RAS server Wa Status COM portis available connection with this desktop m r CO pute Status USB ts available i Allow network Elhemet and Remote Access Service
22. reboots the Windows CE system will use the stored registry data System version System settings Show current CE image version Set serial port mode System settings Set Com1 mode Select Set serial por mode RS232 RS485 2wire or 4wire mode E zz Si Set Com3 RS232 RS485 mode The serial port mode can be saved by Set serial port 3 mode JEE el Save registry 23 HOME Directory Change System settings This can set the Web Server directory Must reboot HMI System settings Contrast HOME Directory Charge Adjust the LCD backlight brightness Contrast 1 Low High 3 2 3 NOR Flash The NORFlash serves as a small Address my Computer ie e Sa capacity hard disk You can store your data and Application y NORFlash Data Documents application in the Flash ROM E via NORF lash function to 3 P Fil T Wind Cortral prevent unexpected loss of data EE Wi deg STEE as power failure When power is Shutdown and cold boot the data in the Flash ROM area would be saved 24 3 2 4 Startup After the system boot up the startup execution function would automatically perform This function is useful for control system to do the initialization processes or some other programs Stepl Create startup directory in the NORFlash folder Step2 Copy executable files or Shortcut to StartUp directory which is created in Step 1 An alternative way to setup startup fil
23. recommended that the unit be mounted on the front panel of a steel enclosure through an appropriate opening Allow a clearance of 1 25mm around the sides of the unit for mounting hardware Allow clearance for cable connections to the back of the unit Unit depth may vary according to cable type used Typically plan a depth to accommodate at least 4 1053mm behind the panel NEMA 4 Put the unit through the panel cut out Slide the clamps into the 6 Mounting holes provided around the case Tighten the clamping screws in an even pattern until the unit is secured in the panel Caution Do not over tighten mounting clamps Note Specifications Note To seal to NEMA 4 specifications all supplied mounting clamps must be used and panel cannot flex more than 0 010 2 1 3 Environmental Considerations The NP 880S are to be used indoors as built in displays Make sure that the displays are installed correctly and that the operating limits are followed See Specifications Do not operate the unit in areas subject to explosion hazards due to flammable gases vapors or dusts The unit should not be installed where fast temperature variations and or high humidity are present This will cause condensation of water in the device Do not install these terminals in environments where have inflammable gases gel Panel mounting clamp 4 places only 2 shown Qeu0d Side View
24. s has been designed to operate satisfactorily in electromagnetic noise immunity and without emitting high levels of electrical noise into the environment emission The units are designed to meet European Community standards when installed per the wiring instructions in this manual Compatibility The NP 880S has been designed to meet electromagnetic Standards compatibility for industrial environments e CISPR EN 55011 Group 1 Class A Radiated Emissions levels e EN50081 2 Generic emission standard industrial environment Also US FCC Class A e EN50082 2 Generic immunity standard industrial environment 2 6 VESA Standard hole The NP 880S VESA Standard hole for wall mounting or arm mounting The M4 screw length is 10 to 15mm Don t over 15mm The CPU board will damage Lilet 18 2 7 Dimensions of NP 880S Front View 43mm 1 85 SEN 10 287 Side View 222mm 874 Cutout dimensions NP 880S 222mm 8 74 W x 167mm 6 57 H ES TTT Rear View 19 Chapter 3 Windows CE NET 3 1 Introduction The NP 880S series operator interface terminal is designed to serve on the Windows CE platform Windows CE NET is the successor to Windows CE 3 0 Designed from the ground up for the embedded marketplace Windows CE NET delivers a robust real time operating system for rapidly building the next generation of smart mobile and small footprint devices With a complete operating system feature set and
25. s may not have enough current to power the NP 8805 Wire lengths should be minimized Maximum 1600 500 m shielded 1000 300 m unshielded Wires should be run in pairs with a neutral or common paired with a hot or signal line If wiring is to be exposed to lightning or surges use appropriate surge suppression devices Keep AC high energy and rapidly switching DC wiring separate from signal wires Equip ungrounded DC supplies with a resistor and capacitor in parallel to earth ground This provides a path for static and high frequency dissipation Typical values to use are 1MOhm and 4700pF To make a connection strip about 3 8 of insulation off the end of the wire turn the connector screw counterclockwise until the gap is wide open insert the wire all the way in and turn the screw clockwise until it s tight Connect positive DC line to the 24V terminal and the DC ground to the GND terminal 11 FUSE Replacement BUSSMANN Fast Acting Glass Tube Rating 250VAC 1A Size 5x20mm Warning 1 Make sure the power off before replace the fuse 2 Do not replace the fuse with a different rating fuse 2 2 2 Grounding Requirements Chassis ground must be used DC ground is not directly coupled to Earth ground internally It is preferable not to ground DC negative return to chassis ground as poor site earths can introduce noise into a system but if necessary an earth connection should be made
26. the host machine without further operator intervention When installation is complete 8 ep931x Setup the following message should Completing the ep931x Setup Wizard appear Completing the EP931X Setup Wizard The installer must press the Finish Click the Finish button to exit the Setup Wizard button in the install window to exit Finish Open the eVC in WCE Configuration toolbars select EP931X Cha Microsoft eMbedded Visual C ti rc IDM MENU Mcnu EEI File Edit wiew Insert Project Build Tools Window Help ZE Le SE 33 3 5 Print NP 880S support PCL language printer You can connect a PCL printer at USB Host port or via Network connect to a shared printer A Edit View Fav ee From Internet Explorer or user s application menu click em As File Page Setup will appear print setup dialog Print Page Setup After the Page Setup click File Print printer Work Offine will print out the data Close Alt F4 Print OK Printer PCL Laser el Port LPT1 el Net Path PCname Printername Paper Size Jaa x C Draft Mode Color Orientation O Portrajt O Landscape Print Range 5 Al O Selection Margins inches Left Daa Top FE Right Dar Bottom nam Printer Printer PCL Laser PCL Inkjet HP DeskJet series inkjet PCL Inkjet PCL Laser printer Support co

Download Pdf Manuals

image

Related Search

Related Contents

10481.14 KB  2 - Christie  仕 様 書  A-Series Service Manual  SWIFTBROADBAND SAFETY SERVICES TEST TOOL USER'S GUIDE  Home Decorators Collection 0815000730 Instructions / Assembly  Limited Product Warranty** NVR`s and DVR`s The  Peavey 51450 Data Sheet  Instrucciones de servicio  Uniross Sprint CR-V3 Set  