1. Table summarising error codes Green Leds Note Temperature indicator i dk Peset Description O flashing light 40 50 60 70 80 90 yellow red lit X Overheat X Insufficient circulation OJo O Insufficient water request filling OO O C H Flow temp probe circuit open short circuit OJO O C H Return temp probe circuit open short circuit O O O External sensor circuit open short circuit O O O Floor thermostat contact open X Heating delivery probe problem O 0 O Insufficient circulation O O EEPROM error O O Communication error Oo O0 0 0 0 O Too many gt 5 resets in 15 minutes oO X Main P C B error O O O Room sensor circuit open short circuit X__ No flame detected O O0O 90 O Flame detected with gas valve closed X Flame lift O O O O 1st Ignition Failed Ojo O O 2nd Ignition Failed O O 90 O Flame cut off X Thermofuse open X Fan speed error Anti frost Device When the electrical supply is turned on the anti frost function acts on the central heating flow temperature probe independently from other safety devices If the primary circuit temperature is between 3 C and 8 C the pump will run with the diverter valve switching between central heating and hot water every 1 minute until the temperature reaches gt 9 C If the flow temp
2. Team Limited Hughenden Avenue Suites 9 amp 10 Plaza 256 High Wycombe Blanchardstown Corporate Park 2 Bucks HP13 5FT Ballycoolin Telephone 01494 755600 Dublin 15 Fax 01494 459775 Telephone 01 810 3723 Internet www aristonthermo co uk Fax 01 810 3727 Internet www aristonthermo ie Technical Advice 0870 241 8180 Customer Service 0870 600 9888 Technical Advice 01 437 0121 Customer Service 01 437 0121 Supplied By www heating spares co Tel 0161 620 6677 420010275700
3. summer operating mode Winter operating mode may be selected by positioning the knob 5 between the min and max settings Adjusting the heating It is possible to set the temperature of the heating water by adjusting the knob 5 By positioning the indicator somewhere between min and max A temperature may be obtained which varies from approximately 40 C to approximately 82 C The water temperature in the primary circuit may be checked by means of the green leds 1 Domestic Hot Water temperature adjustment E COMBI It is possible to set the temperature of the domestic hot water by adjusting the knob 6 A temperature may be obtained which varies from approximately 36 C to approximately 60 C Switching off the heating To switch off the heating mode turn the button 5 to the position o The boiler will now only produce Domestic Hot Water Stand by To switch off the boiler press the ON OFF button 2 The green LED 3 will go off Switch off the boiler completely by switching the external electrical switch to the OFF position Supplied By www heating spares co Tel 0161 620 6677 User Manual Clock Instructions E COMBI 1 General layout The mechanical clock covers a 24 hour period Each tappet repre sents 15 minutes A An override switch is located on the clock B 2 To set the time To set the time of day grasp the outer edge of the dial and turn slow ly clockwise until
4. the declaration of conformity and the operating manual and should provide all necessary information as to how the boiler and the safety devices should be handled This appliance is designed to produce central heating and domestic use only It should be connected to a heating system and a distribution network for domestic hot water both of which must be compatible with its performance and power levels The use of the appliance for purposes other than those specified is strictly forbidden The manufacturer cannot be held responsible for any damage caused by improper incorrect and unreasonable use of the appliance or by the failure to comply with the instructions given in this manual Installation maintenance and all other interventions must be carried out in full conformity with the governing legal regulations and the instructions provided by the manufacturer Incorrect installation can harm persons animals and possessions the manufacturing company shall not be held responsible for any damage caused as a result In the event of any maintenance or other structural work in the immediate vicinity of the ducts or flue gas exhaust devices and their accessories switch the appliance off by switching the external bipolar switch to the OFF position and shutting off the gas valve When the work has been completed ask a qualified technician to check the efficiency of the ducting and the devices If the boiler should be out of use for a prolon
5. If you detect a smell of burning or smoke coming from the appliance disconnect it from the electricity supply turn off the main gas valve open all windows and call for assistance A Personal injury caused by burns smoke inhalation intoxication If there is a strong smell of gas turn off the main gas valve open all windows and call for assistance A Explosions fires or intoxication This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance An User Manual Control panel 10 E SYSTEM Legend Green indicator CH temperature and error indicator ON OFF button Green indicator ON OFF Pressure gauge Winter Summer switch Heating temperature regulation knob Domestic Hot Water adjustment knob E Combi models Time clock E Combi models Green indicator flame ON Red indicator lockout light Yellow indicator flashing error light 10 RESET button ONAN BRWDHDN Ke Supplied By www heating spares co Tel 0161 620 6677 User Manual Initialoperating procedures Filling instructions Check the water p
6. This Document Has Been Provided By Please Visit www heatingspares co or call us on 0161 620 6677 For Spares at Discounted Prices A A R i STO N B ae User s manual E Combi E System CONDENSING WALL HUNG COMBINATION BOILER G C N 47 116 62 24 kW G C N 47 116 63 30 kW G C N 47 116 64 38 kW CONDENSING WALL HUNG 0 H BOILER G C N 41 116 34 24 kW G C N 41 116 35 30 kW Country of destination GB IE REGULATIONS Supplied By www heating spares co Tel 0161 620 6677 User Manual Dear Customer Thank you for choosing an ARISTON boiler We guarantee that your boiler is a reliable and technically sound product This manual provides detailed instructions and recommendations for the correct use of the appliance Remember to keep this manual in a safe place for future reference i e by the boiler Your local ARISTON Servicing Centre is at your complete disposal for all requirements GUARANTEE The manufacturer s guarantee is for 2 years from the date of purchase The guarantee is invalidated if the appliance is not installed in accordance with the recommendations made herein or in a manner not approved by the manufacturer To assist us in providing you with an efficient after sales service please return the guarantee registration card enclosed with the boiler without delay Ariston only obligation under the guarantee will be to repair or replace the faulty appli
7. ance at Ariston discretion This will be carried out where the fault arises from defects within the appliance caused either by material or workmanship of the manufacturer This guarantee does not protect malfunction or damage arising from incorrect installation commissioning or maintenance procedures as laid out in the installation and servicing manual inefficient flue system poor or incorrect electricicty wrong gas supply or pressure tampering by inexperienced persons and any other cause not directly due to manufacture ARISTON GB Limited cannot accept responsibility for any cost arising from repair or maintenance carried out by any third party Repair under the guarantee does not affect the expiry date of the guarantee The guarantee on parts and appliances which are exchanged ends when the guarantee on the original appliance expires This guarantee does not affect your statutory rights You must have your boiler serviced at the end of the first year to validate your guarantee for the second year and ensure the Benchmark serv internal Record is completed The installation and first ignition of the boiler must be performed by qualified personnel in compliance with current national regulations regarding installation and in conformity with any requirements established by local authorities and public health organisations After the boiler has been installed the installer must ensure that the end user receives
8. erature remains between 3 C and 8 C the pump will continue to run for a maximum of 20 minutes unless a temperature above gt 9 C is detected in the central heating flow after this the burner will fire heating position until a temperature of gt 30 C is detected If the central heating flow temperature is lt 3 C the burner will fire heating position at minimum power until the temperature reaches gt 30 C the burner will go out If lockout is caused by overheat the burner will not fire but the pump will continue to run heating position The anti frost device activates only when with the boiler operating correctly the system pressure is correct the boiler is electrically powered there is a supply of gas Change of gas type Our boilers are designed to function either with Natural Gas meth ane or L P G gas If you need to change from one gas to the other one of our Authorised Service Centres must be contacted to convert the appliance Maintenance Schedule an annual maintenance check up for the boiler with a com petent person Correct maintenance generally results in savings in the cost of run ning the system Failure to arrange an annual service for the appliance will invalidate the second year of the manufacturer s guarantee An This Document Has Been Provided By HEATING Please Visit y 5 s co or call us on 5 77 For Spares at Discounted Prices Ariston Thermo UK Ltd Professional
9. ged period it is recommended that the electrical power supply be disconnected and that the external gas cock be closed If low temperatures are expected the boiler and system pipe work should be drained in order to prevent frost damage Turn the boiler off and turn the external switch OFF to clean the exterior parts of the appliance Do not allow children or inexperienced persons to use the appliance without supervision CE labelling The CE mark guarantees that the appliance conforms to the following directives 90 396 CEE relating to gas appliances 2004 108 CEE relating to electromagnetic compatibility 92 42 CEE relating to energy efficiency 2006 95 CEE relating to electrical safety Supplied By www heatin A F User Manual The Benchmark Scheme ARISTON is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of dome stic heating and hot water systems in the UK and to encourage regular servicing to optimise safety efficiency and performance Benchmark is managed and promoted by the Heating and Hotwa ter Industry Council For more information visit www centralheating co uk Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions sup plied with the product and that you have signed it to say that you have received a full and clear explanation of its operatio
10. ified technician Shutdown due to insufficient water circulation If the green leds 1 flash and the boiler is off one possible cause for this state is an insufficient pressure of water in the system green LED 40 50 blink Check the water pressure on the pressure gauge 4 and make sure that is between 0 6 and 1 5 bar when the system is cold If the pressure is just under the minimum refill the system by opening the valve under the boiler If the pressure drops very frequently there may be a water leak at some point in the system If this is the case a plumber should be contacted Note Connections viewed from behind boiler Operation shutdown This type of error is non volatile which means that it is not removed automatically the red LED 8 will illuminate and the C H temperature LED 1 will indicate the error code In this case the boiler does not restart automatically but it may be reset by pressing the eset button If the problem manifests itself again after several attempts to reset the appliance contact a qualified technician Important If this shutdown occurs frequently contact an authorised service centre for assistance For safety reasons the boiler will allow a maximum of 5 reset operations to take place in 15 minutes individual presses of the button If the shutdown is occasional or an isolated event this is not a problem Supplied By www heating spares co Tel 0161 620 6677 User Manual
11. m live components Flooding caused by water leaking from disconnected piping Explosions fires or intoxication caused by gas leaking from disconnected piping Do not damage the power supply cable A Electrocution from live uninsulated wires Do not leave anything on top of the appliance A Personal injury caused by an object falling off the appliance as a result of vibrations Damage to the appliance or items underneath it caused by the object falling off as a result of vibrations Do not climb onto the appliance Personal injury caused by the appliance falling Damage to the appliance or any objects underneath it caused by A the appliance falling away from its installation space Do not climb onto chairs stools ladders or unstable supports to clean the appliance Personal injury caused by falling from a height or cuts stepladders shutting accidentally Do not attempt to clean the appliance without first switching it off and turning the external switch to the OFF position A Electrocution from live components Do not use insecticides solvents or aggressive detergents to clean the appliance A Damage to plastic and painted parts Do not use the appliance for any use other than normal domestic use A Damage to the appliance caused by operation overload Damage caused to objects treated inappropriately Do not allow children or inexperienced individuals to operate the appliance A Damage to the appliance caused by improper use
12. n The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations England and Wales All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regula tions Compliance Certificate will then be issued to the customer who should on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to optimise its safety effi ciency and performance The service engineer should complete the relevant Service Record on the Benchmark Checklist after each ser vice The Benchmark Checklist may be required in the event of any warran ty work and as supporting documentation relating to home improve ments in the optional documents section of the Home Information Pack Safety regulations Key to symbols Failure to comply with this warning implies the risk of personal injury in some circumstances even fatal Failure to comply with this warning implies the risk of damage in some circumstances even serious to property plants or animals Do not perform operations which involve opening the appliance Electrocution from live components Personal injury caused by burns due to overheated components or wounds caused by sharp edges or protrusions Do not perform operations which involve removing the appliance from its installation space A Electrocution fro
13. ressure on the pressure gauge regularly and make sure that the figure is between 0 6 and1 5 bar when the system is cold If the pressure is just under the minimum value re establish the correct pressure by using the filling loop If the pressure drops very frequently there may be a water leak at some point in the system If this is the case a plumber should be contacted Ignition procedure Press the ON OFF button on the control panel to switch on the boiler The green LED 3 will illuminate indicating that the boiler is ready to operate The electronic control unit will ignite the burner without any manual intervention but in response to the request for Domestic Hot Water or Central Heating If after approximately 10 seconds the burner has not ignited the boiler s safety devices will shut off the gas and the red LED 8 illuminates To reset the ignition system the Reset button 10 must be pressed and released Should the boiler fail to ignite a second time check that the external gas cock is open If the problem persists contact an Authorised Service Centre Winter or summer operating modes In the winter operating mode the boiler will produce both Central Heating and Domestic Hot Water In the summer operating mode the boiler will produce only Domestic Hot Water Using the knob on the control panel the user can select winter or summer operating mode Keeping the knob 5 at the position selects the
14. the correct time is lined up with the arrow C 3 To Set the On and Off times The clock uses a 24hours system e g 8 8 00 am and 18 6 00 pm ON periods are set by sliding all tappets between the ON time and the OFF time to the outer edge of the dial The tappets remaining at the centre of the dial are the OFF periods 4 For operation Put the selector switch B to the symbol to control the central heating by the clock Put the switch B to I to select permanent operation or to 0 to turn the central heating off permanently Boiler protection devices The boiler is protected from malfunctioning by means of internal checks performed by the electronic microprocessor P C B which stops the boiler from operating if necessary In the event of the boiler being shut off in this manner the LED shows the type of shut off and the reason behind it There are two types of shut off Safety shut off This type of error is volatile which means that the boiler starts up again automatically as soon as the problem which caused the shut off is removed the yellow LED 9 flashes and the C H temperature LED 1 indicate the error code see table As soon as the cause of the shut off disappears the boiler starts up again and continues to operate normally If the boiler still indicates a safety shut off switch it off Make sure the external electric switch is in the OFF position and contact a qual