Home
DentalVibe GEN3 User Guide
Contents
1. USER MANUAL Get to know your DentalVibe GEN 3 Learn the correct pressure that stimulates the sensory receptors by experiencing the DentalVibe on yourself first 1 Place a new comfort tip on to the DentalVibe and turn it on 4 2 Rest the vibrating tip above your upper lip Apply differing pressure to the skin and you will notice that a light touch delivers the greatest amount of stimulation For one on one personal training call me directly at 561 613 6377 Steven G Goldberg DDS FADFE Inventor of the DentalVibe Laser Calibrated laser calibration covering Elastomeric coated comfort tips are laser calibrated to a specific frequency and amplitude effectively stimulating the mechanoreceptors within the oral mucosa Heat or chemical sterilization causes deformation of the elastomeric rendering the DentalVibe ineffective This specific frequency and amplitude is not attainable with a rigid plastic or metal component Do Not restrict the DentalVibe The covering of a tip with any type of material that restricts the frequency and amplitude will negate the pain blocking effect Any restriction of the vibrating tip creates excessive wear and tear on internal moving components rendering the DentalVibe in effective voiding all warranties WARNING Do Not inject througha plastic sheath as this will deposit plastic particulate matter submucosally acting as a foci for foreign body infection Char
2. 2 After each patient use return the DentalVibe unit back to it s charging base Note Safe with pacemaker defibrillator when used normally in accordance with intended use INSTALLING REMOVING COMFORT TIP DO NOT RE USE A BIOHAZARD AFTER USE EDA ca Infection control protocol for comfort tips A WARNING Do Not re use the Tip Comfort Tips must be disposed of after each patient use to prevent cross contamination and ensure FDA compliance of infection control protocols These tips are porous contain microfilaments and will harbor blood saliva and bacteria Dispose of used White Tip in red bag hazardous waste Injections with DentalVibe 1 The use of a topical anesthetic is optional 2 Hold the DentalVibe as a retractor in a similar fashion as you would hold a dental mirror It is designed with the same angles for ease of use 3 Activate the DentalVibe by fully depressing the On Off button and then introduce the vibration to your patient by gently touching the back of their hand or on the outside of their cheek before placing in the mouth 4 Position DentalVibe s Comfort Tip on the oral mucosa at the injection site see photos Note A light touch is all that is needed Excessive pressure will dampen the vibration negating the pain blocking effect For Infiltrations and Mandibular Blocks IA maneuver to retract the lip cheek as you would with a dental mirror For Palatal injections position
3. YEAR FROM DATE OF ORIGINAL PURCHASE IN NO EVENT WILL BING INNOVATIONS LLC BE RESPONSIBLE FOR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other legal rights which vary from state to state OBTAINING SERVICE Should this product require service please call 1 877 503 VIBE 8423 to be referred to the authorized Bing Innovations LLC Service Center closest to you Contact us at any time for battery replacement and unit recalibration for a service fee of 50 includes return shipping cost in U S EXPLANATION OF SYMBOLS Consult User Manual AN Electrical Hazard Do Not Re Use Ol Double Insulated Biohazard after use atal Manufacturer Warning European Conformity Type B applied part European Authorized Rep BIN iG F INNOVATIONS al BING INNOVATIONS LLC 990 South Rogers Circle Suite 4 Boca Raton FL 33487 877 503 VIBE 8423 www DentalVibe com info dentalvibe com CE European Authorized Representative AR Mdi Europa GmbH EC REP Langenhagener Str 71 30855 Langenhagen 2014 Bing Innovations LLC All rights reserved Under the copyright laws this manual may not be copied in whole or in part without the express written consent of Bing Innovations LLC Every effort has been made
4. or charger in water or other liquid Do not reach for a charger that has fallen into water Unplug immediately Use this type B applied product only for its intended use as described in the manual Do not use attachments or chargers not recommended by the manufacturer Position the charger so the power supply is easy to unplug Never insert any objects into any opening of the unit or charger base Never operate the product if it has a damaged cord or plug not working properly has been dropped damaged or submerged into water If any of these occur contact a service center and return the product for examination and repair A IMPORTANT E 8 Periodically check the cord for damage If cord is damaged ship the charging unit to a Bing Innovations Service Center A damaged or non functioning unit should no longer be used Do not touch the power cord with wet hands as this can cause electric shock 10 11 When unplugging always hold the power plug instead of the cord Do not put metal objects such as coins or clips on the charger This may generate heat damaging the unit and heating the metal item presenting potential burn hazards No User Serviceable Parts Do not modify this equipment without authorization of the manufacturer If equipment is modified appropriate inspection and testing must be conducted to ensure continued safe use Batteries are not user serviceable Equipment protected f
5. e and ensure that the surface remains visibly wet for 1 minute at room temperature 68 F 20 C e Do Not place DentalVibe or Comfort Tip in an autoclave e Do Not immerse DentalVibe or Charger in water e Remove the power cord plug from the electrical outlet before cleaning the charger Permissible environmental conditions during normal use Temperature Humidity Barometric Pressure Operating 18 C to 30 C 30 85 RH 100kpa 50kpa Storage 20 C to 45 C 10 85 RH 100kpa 50kpa A DO NOT OPEN THE DENTALVIBE OR CHARGING BASE The internal circuit boards are manufactured in a static free environment For service or battery replacement please call 1 877 503 VIBE 8423 for an authorized Bing Innovations LLC Service Center closest to you INTENDED USE DentalVibe is intended for use by dental professionals in a dental office setting It has been carefully designed to offer your patients a more comfortable dental injection experience that is both safe and effective It does not modify the tissue or impart energy and is not intended for therapeutic diagnostic or any other purpose e The use of the DentalVibe varies between 10 60 seconds per application e Contraindication for use Do not use in an area where an abcess is present A WARNING Read all instructions before use AA WwW N gt nn Do not place or store the charger where it can fall or be pulled into a sink Do not place the hand held unit
6. ging DentalVibe is equipped with a Nickel Metal Hydride NiMH rechargeable battery Model GTM 41076 0615 Only use provided power supply _ next 100 240v 50 60Hz 0 58 Output 15V 0 4A 1 Insert power supply cord into recepticle on charger base plug power supply into an electrical outlet Use international plug adaptors as needed 2 Charge the DentalVibe at least 15 hours before initial use 3 After each patient use place the DentalVibe back in it s charging base Note Battery does not experience the memory effect DENTALVIBE LED INDICATOR LIGHT BLINKS GREEN on charger when ready for use BLINKS AMBER on charger while charging BLINKS AMBER off charger when in need of a charge Note DentalVibe needs to be placed on charger until light blinks green Comfort Tip Note Comfort Tips are Latex Free Installing the Comfort Tip for use Remove a fresh Comfort Tip from it s sealed bag in plain view of your patient Align the arrow on the Comfort Tip with the arrow on the DentalVibe unit Push straight down until it snaps on securely see photos You are now ready to deliver a comfortable injection Removing the Comfort Tip after use 1 While holding the DentalVibe unit in one hand grasp the clear plastic portion of the Comfort Tip with your other hand rotate 180 counter clockwise and lift up to remove The tip will tear preventing re use and cross contamination
7. rom AC power by double insulation or reinforced insulation by use of the supplied power supply Will not cause electromagnetic interference and complies with 601 1 2 10 Limited 1 year warranty Bing Innovations LLC warrants this appliance to be free of defects in material and workmanship for a period of one year from the date of original purchase If appliance exhibits such a defect Bing Innovations LLC will at its option repair or replace it without cost for parts and labor The product must be shipped prepaid and insured recommended to an authorized Bing Innovations LLC Service Center Proof of date of original purchase is required The cost to ship the product to an authorized Service Center is the responsibility of the dental practice the cost to return the product to the dental practice is the responsibility of Bing Innovations Warranty does not cover finishes or normal wear nor does it cover damage resulting from accident misuse dirt water tampering unreasonable use use of any tip other than those supplied by Bing Innovations LLC or covering the tip with a plastic sleeve service performed or attempted by unauthorized service agencies failure to provide reasonable and necessary maintenance including recharging or units that have been modified or used for commercial purposes ALL IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE
8. the very tip of one of the prongs on the palate see photos 5 Use the DentalVibe to stimulate the injection site for 3 5 seconds before inserting the needle Maintain tissue contact and keep the vibrating prongs on the 6 oral mucosa while injecting With maxillary infiltrations avoid vibrating the maxilla as this may cause discomfort in some patients Exception For Mandibular Blocks IA you must push the vibrating prongs deeper into the buccal mucosa and vibrate the mandible while simultaneously injecting 6 Always insert the needle as close as possible Effective Area to one of the vibrating prongs The strongest vibration is adjacent to the edges of the i prongs see effective area Note Itis okay if amp the needle touches the vibrating prong 7 Continue stimulation of the oral mucosa until delivery of the anesthetic solution is complete Then remove the needle and continue tissue stimulation for an additional 3 5 seconds This will help diffuse the solution through the tissue periosteum and bone 8 Shut off the DentalVibe by fully depressing the on off button Infiltrations Palatal Watch included CD or visit www dentalvibe com training for instructional videos Caring for your DentalVibe SUPPLIED PARTS DentalVibe hand piece Charging base with Power Supply and Comfort Tips CLEANING INSTRUCTIONS Wipe handle clean with plastic safe surface disinfectant Thoroughly wet the handl
9. to ensure that the information in this manual is accurate Bing Innovations LLC is not responsible for printing or clerical errors Patented in U S amp Canada Other U S and foreign patents pending FDA Registered Reverse engineering or disassembly is prohibited Model Name DentalVibe GEN 3 Model DV0003 Manufactured in the USA REV 1 2014 01 31
Download Pdf Manuals